lcn automatic operators · lcn automatic operators senior swing 9530 senior swing 9540 senior swing...
TRANSCRIPT
LCN AUTOMATIC OPERATORS
SENIOR SWING 9530
SENIOR SWING 9540
SENIOR SWING 9550
SENIOR SWING 9560
8310 ACCESSORIES
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com8/0753
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
LCN ELECTROMECHANICAL POWERED SYSTEMSELECTROMECHANICAL AUTOMATIC OPERATORSLCN’s electromechanical products are designed primarily forautomatic opening applications that occasionally requiremanual opening. A control box provides all electricalfunctions. These self-contained units are suitable for use onsingle leaf doors or pair of doors. These products combine allthe control and power elements into a single operator package,only some actuators are required to complete the system.
Surface mounted and overhead concealed mountingsavailable.Available in two standard anodized finishes – aluminumand dark bronze. Custom anodized finishes and custompaint is available.
LOW ENERGY ELECTROMECHANICAL POWER OPERATORSComplies with ANSI 156.19Opening time from full close to backcheck is no faster than3 secondsLess than 15lbs of force to open door manually
HIGH ENERGY ELECTROMECHANICAL POWEROPERATORSComplies with ANSI 156.10Opening time from full close to backcheck is no faster than1.5 secondsLess than 30 lbs of force to open door manuallyRequires use of guide rails and safety devices
STANDARDS, LISTINGS & APPROVALS UL listed for self-closing doors without hold open. UL 325.Tested and certified under ANSI.Low Energy Electromechanical Operators ANSI 156.19High Energy Electromechanical Operators ANSI 156.10ADA Compliant. Applicable to Low Energy Electromechanical Operators only.Wiring is compliant with both UL 325 and the NEC.Separation of high and low voltage.Consult the factory for other listings.
WARRANTY2 year limited warranty. See General Section forcomplete details
MAINTENANCELow Energy Electromechanical Power Operators
Operators mounted according to the LCN Installationinstructions require no periodic maintenance oradjustments. Monthly, quarterly and annual visual inspections arerecommended.No service contracts.
High Energy Electromechanical Power OperatorsHigh energy automatic operators may require periodicmaintenance and/or adjustments.Daily visual inspections are recommended to ensureproper operation of all activation and safety devices.
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com8/0758
LCN ELECTROMECHANICAL POWERED SYSTEMSGENERAL ELECTRICAL DATA1. Input power 115 volt, 3 wire, single phase, 60Hz, fused, 15 amp supply.2. UL approved type flexible conduit is recommended for the 115 volt power line.3. The 115 volt power supply must be a dedicated circuit from the main circuit breaker panel and must not be
connected into a building lighting system operating fluorescent lights.4. Location of conduits determined by mounting. See installation instructions for location.
2500, 2800, 2900, 9300, 9500, 9700 SeriesELECTRICAL DATA1. 120 VAC input @ 2.5 amps (2500 and 9300 Series).2. 120 VAC input @ 2.5 amps (2800, 2900,9500 and 9700 Series).3. 24 V AC output @ 1.5 amps (protected by self-resetting thermal fuse).4. 24 V DC available with SO kit included.9100 SeriesELECTRICAL DATA1. 120 VAC input @ 1 amp. 2. 17 VAC output @ 2.5 amps on premium control box.3. 24 VDC available with SO kit included with premium control box.
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com8/0754
LCN ELECTROMECHANICAL POWERED SYSTEMS
SINGLE DOOR SYSTEM (Low Energy)An Interior Door.No guide rails or safety devices.Free Swinging (or Dogged) Door.
How It Works
Wireless RF actuators with receiver, powered by thetransformer allows for easy installation. For automaticdoor operation, touching either actuator signals thereceiver and power operator to open the door to 90degrees. The door is held there until the system timesout. Door closes via spring return. Door opening speed,closing speed and hold open time is adjustable on thecontrol box. If not actuated, the power operatorfunctions as a manual door.
120VInput
Low Voltage Wiring
RF Receiver
RF Actuator
RF Actuator
Automatic Operator
SINGLE DOOR SYSTEMS
VESTIBULE ENTRY SYSTEM (Low Energy)
Exterior & Vestibule doors.
Sequential Operation.
No guide rails or safety devices.Controlled Access, Free Egress.
How It Works
This installation provides both accessibility and securityfor building occupants. It allows for the integration ofmultiple automatic operators, a card reader and electricstrike. A sequencer allows sequential operation of thetwo automatic operators. Vestibule actuators allowsingle door ingress/egress from the vestibule asneeded. If not actuated the power operator functionsas a manual door.
Low Voltage Wiring
Wall Plate Actuator
Automatic Operator
Automatic Operator
Card Reader w/keypad as Exterior Actuator
Sequencer
Electric Strike
Low Voltage
Wall Plate Actuator
Wall Plate Actuator
Note: 120V AC Input required to both operators
120V Input
120V Input
VESTIBULE ENTRY OPERATION
BILL OF MATERIALSQty. Part No. Description1 9542 Automatic operator (RH)1 9531 Automatic operator (RH)3 8310-853 Wall Plate Actuators1 8310-849 Sequencer
Other products from Von Duprin and Locknetics
BILL OF MATERIALSQty. Part No. Description1 9531 Automatic Operator (RH)2 8310-3853WS RF Actuators1 8310-865 RF Receiver
This page illustrates examples of typical Electromechanical LCN systems. Pleaseconsult your local SSC representative of LCN for assistance with specificinstallations and material requirements.
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/1097
LCN 9530 SERIES
STANDARD ANODIZED
CUSTOMANODIZED
CUSTOMPAIN
T
FINISH HANDING
HANDED
NON-HANDED
COVER
METAL
ARM FUNCTION
STANDARD (SIN
GLE)
REGULAR (D
OUBLE)
OFFSET PIVOT ARM
CENTER PIVOT ARM
DOUBLEEGRESS (PUSH/PULL
)
MOUNTING
SURFACE MOUNT SIN
GLEDOOR
SURFACE MOUNT SIM
ULTANEOUS PAIR
SURFACE MOUNT IN
DEPENDENT PAIR
CONCEALED SIN
GLEDOOR
CONCEALED IN
DEPENDENT PAIR
CONCEALED SIM
ULTANEOUS PAIR
The 9530 SENIOR SWING by LCN is anADA door operator that is a two-in-one swing door operator. SENIORSWING operators when activated,opens doors automatically forwheelchair access, yet allows formanual operation for regularpedestrian traffic.
Push ‘N Go permits non-switchactivationPower Boost provides additionallatching forceElectromechanical unit withmicroprocessor controlDigital keypad for easy setupMeets International Building Coderequirements and ANSI A156.19UL approved for fire doors
9530 Series is fully compliant with UL325 & UL 1998 and meets theprovisions of ANSI A156.19. The 9530Series is UL listed for fire-ratedapplications. The 9530 Series alsomeets the provisions of the Americanswith Disabilities Act.
9530 series operator is shipped with motor gearbox, control box,standard arm, header, and mounting hardware. Actuators availableseparately, see pages 121.
Single door, surface mounted.
Meets ADA requirements (power mode only).
Handed product.
36” header length is standard. Specify length 33” to 49” max.
Double door header available up to 98”, specify other length 49” to 98”max. Consult factory regarding this option.
Adjustable hold open period of 1 to 32 seconds in automatic or manualmode.
SINGLE DOOR, SURFACE MOUNT (PULL)OFFSET PIVOT/BUTT HINGE FEA
TURE
S
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/1098
Butt Hinges should not exceed 5” (127 mm) in width.
Reveal should not exceed 4” (102 mm).
Head Frame minimum 1 3/4” (44 mm). Face frame 6 3/4” (171 mm)total operator clearance.
Top Rail minimum 2 3/4” (70 mm).
Opening & Closing Time are variable by adjustments to the electroniccontrol box. Maximum hold open time adjustable up to approximately32 seconds.
System Diagram see “AUTOMATIC OPERATORS” section pages 52-54for typical system wiring and page 55 for electrical data.
Please consult your local SSC representative or LCN for assistance withspecific installations and material requirements.
TOP JAMB SINGLE DOOR(OFFSET PIVOT/BUTT HINGE,CENTER PIVOT, PULL)MOUNTING
HOLLOW METAL FRAMESuggested Installation
MAXIMUM OPENINGTemplate allows 90 degree poweropening and 90 degree manualopening.
LCN 9530 SERIES
PULL ARM ASS'Y
OFFSET PIVOT
or BUTT
HINGES
2 3/4
"70 MM
SWING OPERATOR
48" DOOR OPENING (MAX.)
INCOMING
LEFT HAND
PULL CHANEL
1 3/4
"44 MM
SWING OPERATOR
4 1/2
"114 MM
6 3/4
"171 MM
5 3/4
"146 MM
DOOR
SWING DIRECTION
INTERIOR
PULL CHANEL
PULL ARM ASS'Y
1"25 MM
1 15/16
"49 MM
17
3/8
" 11
1/2
"292 MM
Special TemplatesCustomized installation templates or products may be available to solve unusual applications. Contact LCN for assistance.
MOUN
TINGD
ETAILS
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/1099
LCN 9530 SERIES MOTOR GEARBOXMOTOR GEARBOX (STANDARD FORCE) –SENIOR SWING, 9530-3454Driving mechanism for operator. Provides 15lbs opening force.Handed.
MOUNTING BRACKETMOUNTING BRACKET – 2 3/4”, 9530-275Motor gearbox mounting bracket for 2 3/4" offset pivot or butt hingeinstallations. Front bracket.
REAR MOUNT BRACKET, 9530-3018Motor gearbox mounting bracket. Rear bracket.
ANGLED BRACKET, 9530-334-1Mounting bracket for surface applications.
CONTROL BOXESCONTROL BOX – SENIOR SWING, 9530-3462Electronic controlling device for Senior Swing.
HEADERSHeader, 9530-3572HLStandard, mounting header. Single door, single operator.Specify length 30”to 49” maximum.
Header, 9530-3572DDStandard, mounting header. Double door, single operator. Specify length 49”to 98” maximum.
END CAPSHEADER END CAPS, 9530-334End cap with openings for wiring.
END DRESS PLATE, 9530-334-2Metal finish end cap.
ACCE
SSOR
IES3454
275 3018 344-1
3462
3572HL
3572DD
334 334-2
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10100
ARMSSTANDARD ARM ASSEMBLY, 9530-3077PLCMHanded arm.
STANDARD ARM, 9530-3077THanded arm. Track roller not included.
TRACKSTRACK 9530-3038Standard non-handed track.
TRACK END CAP 9530-73Black plastic end caps.
ROLLER, 9530-3034Quiet low friction roller assembly.
INSTALLATION ACCESSORIES
SPINDLE PLATE – 2 3/4”, 9530-11AHides bottom of motor gearbox. Completes header box. Cutoutallows for motor gearbox shaft. For 2 3/4" offset pivot or butthinge installations.
FILLER PLATE BLANK, 9530-12Completes length of header box. (Specify Length)
MOUNTING PLATE, 9530-18Optional mounting plate for standard hollow metal doorframes. Specify length 33” to 98” maximum.NOTE: The length of a universal 18 plate will need to beordered 3 1/2” longer than the supplied header.
ACCE
SSOR
IES
LCN 9530 SERIES 3077PLCM
3077T
3038 3034
11A
73
12
18
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10101
TABLE OF SIZES Indicates recommended range of door width for operator.
Note: For all Senior Swing SeriesSingle Door - Width per leaf 36” minimum, 48” maximum
LCN 9530 SERIES
DOOR WIDTH
36"914mm
48"1219mm
9531
MinimumDoor
Width
HOW-TO-ORDER9530 SERIES OPERATORS
1. SPECIFY HANDRHLH
2. SPECIFY FINISH.Standard Anodized Finish _____________Aluminum or Dark Bronze
Operator will be shipped with:-STANDARD MOTOR GEARBOX (SF)-STANDARD CONTROL BOX (SC)-36” HEADER (36HL)-STANDARD ARM (3077T)-2 3/4” PIVOT POINT-STANDARD TRACK w/TRACK ROLLER-MACHINE SCREW PACKUnless options listed below are selected.
OPERATOR OPTIONS
HEADERHL __ (Specify length 36” to 49”)DD__ (Specify length 49” to 98”)
MOUNTING PLATEPlate, ____ (Specify Length 30” to 98”)
SPECIAL TEMPLATEST-_________
ORDE
RINGI
NFOR
MATIO
N
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10103
LCN 9540 SERIES
STANDARD ANODIZED
CUSTOMANODIZED
CUSTOMPAIN
T
FINISH HANDING
HANDED
NON-HANDED
COVER
METAL
ARM FUNCTION
STANDARD (SIN
GLE)
REGULAR (D
OUBLE)
OFFSET PIVOT ARM
CENTER PIVOT ARM
DOUBLEEGRESS (PUSH/PULL
)
MOUNTING
SURFACE MOUNT SIN
GLEDOOR
SURFACE MOUNT SIM
ULTANEOUS PAIR
SURFACE MOUNT IN
DEPENDENT PAIR
CONCEALED SIN
GLEDOOR
CONCEALED IN
DEPENDENT PAIR
CONCEALED SIM
ULTANEOUS PAIR
The 9540 SENIOR SWING by LCN is anADA door operator that is a two-in-one swing door operator. SENIORSWING operators when activated,opens doors automatically forwheelchair access, yet allows formanual operation for regularpedestrian traffic.
Push ‘N Go permits non-switchactivationPower Boost provides additionallatching forceElectromechanical unit withmicroprocessor controlDigital keypad for easy setupMeets International Building Coderequirements and ANSI A156.19UL approved for fire doors
9540 Series is fully compliant with UL325 & UL 1998 and meets theprovisions of ANSI A156.19. The 9540Series is UL listed for fire-ratedapplications. The 9540 Series alsomeets the provisions of the Americanswith Disabilities Act.
9540 series operator is shipped with motor gearbox, control box, regulararm, header, and mounting hardware. Actuators available separately,see page 121.
Single door, surface mounted.
Meets ADA requirements (power mode only).
Handed product.
36” header length is standard. Specify length 33” to 49” max.
Double door header available up to 98”, specify other length 49” to 98”max. Consult factory regarding this option.
Adjustable hold open period of 1 to 32 seconds in automatic or manualmode.
SINGLE DOOR, SURFACE MOUNT (PUSH)OFFSET PIVOT/BUTT HINGE FEA
TURE
S
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10104
Butt Hinges should not exceed 5” (127 mm) in width.
Reveal for push installations should not exceed 10” (254 mm) forREGULAR ARM and 20” (508 mm) for LONG ARM.
Head Frame minimum 1 3/4” (44 mm). Face frame 6 3/4” (171 mm)total operator clearance.
Top Rail minimum 2 3/4” (70 mm).
Opening & Closing Time are variable by adjustments to the electroniccontrol box. Maximum hold open time adjustable up to approximately32 seconds.
System Diagram see “AUTOMATIC OPERATORS” section pages 52-54for typical system wiring and page 55 for electrical data.
Please consult your local SSC representative or LCN for assistance withspecific installations and material requirements.
TOP JAMB SINGLE DOOR(OFFSET PIVOT/BUTT HINGE,CENTER PIVOT, PUSH) MOUNTI
Consult factory for all balancedoor installations.
HOLLOW METAL FRAMESuggested Installation
MAXIMUM OPENINGTemplate allows 90 degree poweropening and 90 degree manualopening.
LCN 9540 SERIES
Special TemplatesCustomized installation templates or products may be available to solve unusual applications. Contact LCN for assistance.
MOUN
TINGD
ETAILS
OUTGOING
PUSH ARM ASS'Y
17" From edge of door
OFFSET PIVOT
or BUTT
HINGES
2 3/4
"70 MM
SWING OPERATOR
48" DOOR OPENING (MAX.)
RE
VE
AL
SWING OPERATOR
4 1/2
"114 MM
6 3/4
"171 MM
5 3/4
"146 MM
1"25 MM
DOOR
SWING DIRECTION
DOOR FRAME
EXTERIOR
1 7/16
" From top of door
SECONDARY LINK
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10105
LCN 9540 SERIES MOTOR GEARBOXMOTOR GEARBOX (STANDARD FORCE) –SENIOR SWING, 9540-3454Driving mechanism for operator. Provides 15lbs opening force.Handed.
MOUNTING BRACKETMOUNTING BRACKET – 2 3/4”, 9540-275Motor gearbox mounting bracket for 2 3/4" offset pivot or butt hingeinstallations. Front bracket.
REAR MOUNT BRACKET, 9540-3018Motor gearbox mounting bracket. Rear bracket.
ANGLED BRACKET, 9540-334-1Mounting bracket for surface applications.
CONTROL BOXESCONTROL BOX – SENIOR SWING, 9540-3462Electronic controlling device for Senior Swing.
HEADERSHeader, 9540-3572HLStandard, mounting header. Single door, single operator.Specify length 30”to 49” maximum.
Header, 9540-3572DDStandard, mounting header. Double door, single operator.Specify length 49”to 98” maximum.
END CAPSHEADER END CAPS, 9540-334End cap with openings for wiring.
END DRESS PLATE, 9540-334-2Metal finish end cap.
ACCE
SSOR
IES3454
275 3018 344-1
3462
3572HL
3572DD
334 334-2
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10106
ARMSREGULAR ARM ASSEMBLY, 9540-3077Handed arm.
REGULAR LONG ARM ASSEMBLY, 9540-3077LHanded arm.
MAIN ARM, 9540 -77Handed arm attaches to motor gearbox.
LINKAGE ASSEMBLY – 15”, 9540-79Threaded rod attaches to door. Extends from main arm.
LINKAGE ASSEMBLY – 32”, 9540-79LRThreaded long rod attaches to door. Extends from main arm.Used for reveal 10” to 20”.
INSTALLATION ACCESSORIESSPINDLE PLATE – 2 3/4”, 9540-11AHides bottom of motor gearbox. Completes header box. Cutoutallows for motor gearbox shaft. For 2 3/4" offset pivot or butthinge installations.
FILLER PLATE BLANK, 9540-12Completes length of header box. (Specify Length)
MOUNTING PLATE, 9540-18Optional mounting plate for standard hollow metal doorframes. Specify length 33” to 98” maximum.NOTE: The length of a universal 18 plate will need to beordered 3 1/2” longer than the supplied header.
ACCE
SSOR
IES
LCN 9540 SERIES 30773077L
77
7979LR
11A
12
18
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10107
TABLE OF SIZES Indicates recommended range of door width for operator.
Note: For all Senior Swing SeriesSingle Door - Width per leaf 36” minimum, 48” maximum
LCN 9540 SERIES
DOOR WIDTH
36"914mm
48"1219mm
9542
MinimumDoor
Width
HOW-TO-ORDER9540 SERIES OPERATORS
1. SPECIFY HANDRHLH
2. SPECIFY FINISH.Standard Anodized Finish _____________Aluminum or Dark Bronze
Operator will be shipped with:-STANDARD MOTOR GEARBOX (SF)-STANDARD CONTROL BOX (SC)-36” HEADER (36HL)-REGULAR ARM (3077)-2 3/4” PIVOT POINT-WOOD and MACHINE SCREW PACKUnless options listed below are selected.
OPERATOR OPTIONSHEADER
HL __ (Specify length 36” to 49”)DD__ (Specify length 49” to 98”)
MOUNTING PLATEPlate, ____ (Specify Length 30” to 98”)
ARMLong Arm (3077L)
FINISHSPECIAL TEMPLATE
ST-_________
ORDE
RINGI
NFOR
MATIO
N
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10109
LCN 9550 SERIES
STANDARD ANODIZED
CUSTOMANODIZED
CUSTOMPAIN
T
FINISH HANDING
HANDED
NON-HANDED
COVER
METAL
ARM FUNCTION
STANDARD (SIN
GLE)
REGULAR (D
OUBLE)
OFFSET PIVOT ARM
CENTER PIVOT ARM
DOUBLEEGRESS (PUSH/PULL
)
MOUNTING
SURFACE MOUNT SIN
GLEDOOR
SURFACE MOUNT SIM
ULTANEOUS PAIR
SURFACE MOUNT IN
DEPENDENT PAIR
CONCEALED SIN
GLEDOOR
CONCEALED IN
DEPENDENT PAIR
CONCEALED SIM
ULTANEOUS PAIR
The 9550 SENIOR SWING by LCN is anADA door operator that is a two-in-one swing door operator. SENIORSWING operators when activated,opens doors automatically forwheelchair access, yet allows formanual operation for regularpedestrian traffic.
Push ‘N Go permits non-switchactivationPower Boost provides additionallatching forceElectromechanical unit withmicroprocessor controlDigital keypad for easy setupMeets International Building Coderequirements and ANSI A156.19UL approved for fire doors
9550 Series is fully compliant with UL325 & UL 1998 and meets theprovisions of ANSI A156.19. The 9550Series is UL listed for fire-ratedapplications. The 9550 Series alsomeets the provisions of the Americanswith Disabilities Act.
9550 series operator is shipped with motor gearboxes, control box,arms, header, and mounting hardware. Actuators available separately,see pages 121.
Simultaneous pair, surface mounted.
Meets ADA requirements (power mode only).
Handed product.
Pull, Push or Double Egress applications available.
72” header length is standard. Specify other length 60” to 98”. Consultfactory regarding this option.
Adjustable hold open period of 1 to 32 seconds in automatic or manualmode.
OPERATOR MOUNTSSIMULTANEOUS PAIR, SURFACE MOUNT
*PULL SIDEPUSH SIDE
DOUBLE EGRESS
FEATU
RES
*PULL SIDE mount shown
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10110
Butt Hinges should not exceed 5” (127 mm) in width.
Reveal for push installations should not exceed 10” (254 mm) forREGULAR ARM and 20” (508 mm) for LONG ARM.
Reveal for pull installations should not exceed 4” (102 mm).
Reveal for double egress installations should not exceed 4” (102 mm).
Head Frame minimum 1 3/4” (44 mm). Face frame 6 3/4” (171 mm)total operator clearance.
Top Rail minimum 2 3/4” (70 mm).
Opening & Closing Time are variable by adjustments to the electroniccontrol box. Maximum hold open time adjustable up to approximately32 seconds.
System Diagram see “AUTOMATIC OPERATORS” section pages 52-54for typical system wiring and page 55 for electrical data.
Please consult your local SSC representative or LCN for assistance withspecific installations and material requirements.
TOP JAMB SIMULTANEOUSPAIR (OFFSET PIVOT/BUTTHINGE, CENTER PIVOT, PUSH)MOUNTING
TOP JAMB SIMULTANEOUSPAIR (OFFSET PIVOT/BUTTHINGE, CENTER PIVOT, PULL)MOUNTING
MAXIMUM OPENINGTemplate allows 90 degree poweropening and 90 degree manualopening.
LCN 9550 SERIES
Special TemplatesCustomized installation templatesor products may be available tosolve unusual applications. Contact LCN for assistance.
MOUN
TINGD
ETAILS
OUTGOING
PUSH ARM ASS'Y
17" From edge of door
OFFSET PIVOT or BUTT HINGES
2 3/4
"70 MM
SWING OPERATOR
8'-0" DOOR OPENING (MAX.)
RE
VE
AL
OUTGOING
SWING OPERATOR
4 1/2
"114 MM
6 3/4
"171 MM
5 3/4
"146 MM
1"25 MM
DOOR
SWING DIRECTION
DOOR FRAME
EXTERIOR
1 7/16
" From top of door
SECONDARY LINK
PULL ARM ASS'Y
OFFSET PIVOT
or BUTT
HINGES
2 3/4
"70 MM
SWING OPERATOR
8'-0" DOOR OPENING (MAX.)
INCOMING
INCOMING
PULL CHANNEL
INTERIOR
17
3/8
"441 MM
1 3/4
"44 MM
11
1/2
"291 MM
SWING OPERATOR
4 1/2
"114 MM
6 3/4
"171 MM
5 3/4
"146 MM
1"25 MM
DOOR
SWING DIRECTION
PULL ARM ASS'Y
INTERIOR
PULL CHANNEL
1 15/16
"49 MM
Butt Hinges should not exceed 5” (127 mm) in width.
Reveal for push installations should not exceed 10” (254 mm) forREGULAR ARM and 20” (508 mm) for LONG ARM.
Reveal for pull installations should not exceed 4” (102 mm).
Reveal for double egress installations should not exceed 4” (102 mm).
Head Frame minimum 1 3/4” (44 mm). Face frame 6 3/4” (171 mm)total operator clearance.
Top Rail minimum 2 3/4” (70 mm).
Opening & Closing Time are variable by adjustments to the electroniccontrol box. Maximum hold open time adjustable up to approximately32 seconds.
System Diagram see “AUTOMATIC OPERATORS” section pages 52-54for typical system wiring and page 55 for electrical data.
Please consult your local SSC representative or LCN for assistance withspecific installations and material requirements.
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10111
TOP JAMB SIMULTANEOUSPAIR (RH DOUBLE EGRESS)MOUNTING
Consult factory for all balancedoor installations.
HOLLOW METAL FRAMESuggested Installation
MAXIMUM OPENINGTemplate allows 90 degree poweropening and 90 degree manualopening.
LCN 9550 SERIES
Special TemplatesCustomized installation templatesor products may be available tosolve unusual applications. Contact LCN for assistance.
MOUN
TINGD
ETAILS
SWING OPERATOR
4 1/2
"114 MM
INTERIOR
PUSH ARM ASS'Y
PULL ARM ASS'Y
SWING OPERATOR
SWING OPERATOR
48" DOOR OPENING (MAX.)
2 3/4
"70 MM
48" DOOR OPENING (MAX.)
2 3/4
"70 MM
1 3/4
"44 MM
17" From edge of door
BUTT HINGES
11
1/2
"292 MM
17
3/8
"PULL CHANNEL
SWING OPERATOR
4 1/2
"114 MM
5 3/4
"146 MM
53/
4"
146
MM
6 3/4
"171 MM
SECONDARY LINK DOOR
FRAME
SWING DIRECTION
SWING DIRECTION
DOOR FRAME
DOOR
DOOR
1"25 MM
1"25 MM
23/
18"
FR
OM
BO
TTO
MO
FD
OO
RS
TOP
PULL ARM ASS'Y
PUSH ARM ASS'Y
115
/16"
FR
OM
TOP
OF
DO
OR
PULL CHANNEL
BUTT HINGES
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10112
LCN 9550 SERIES MOTOR GEARBOXMOTOR GEARBOX (STANDARD FORCE)– SENIOR SWING, 9550-3454
Driving mechanism for operator. Provides 15lbs opening force. Handed.
MOUNTING BRACKETSMOUNTING BRACKET – 2 3/4”, 9550-275Motor gearbox mounting bracket for 2 3/4" offset pivot or butt hinge installations. Front bracket.
REAR MOUNT BRACKET, 9550-3018Motor gearbox mounting bracket. Rear bracket.
ANGLED BRACKET, 9550-334-1Mounting bracket for surface applications.
CONTROL BOXESCONTROL BOX – SENIOR SWING, 9550-3462Electronic controlling device for Senior Swing.
COMPANION CABLE, 9550-982Cable that allows one control box to run two motor gear boxes.Companion cable. For use with Senior Swing.
HEADERSHEADER, 9550-3572HLStandard, mounting header. Pair door, two operators. Specify length 60”to 98” maximum.
END CAPSHEADER ENDCAPS, 9550-334End cap with openings for wiring.
END DRESS PLATE, 9550-334-2Metal finish end cap.
ACCE
SSOR
IES 3454
275 3018 344-1
3462
982
3572HL
334 334-2
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10113
ARMSSTANDARD ARM ASSEMBLY, 9550-3077PLCMHanded arm.
REGULAR ARM ASSEMBLY, 9550-3077Handed arm.
REGULAR LONG ARM ASSEMBLY, 9550-3077LHanded arm.
STANDARD ARM, 9550-3077THanded arm. Track roller not included.
MAIN ARM, 9550 -77Handed arm attaches to motor gearbox
LINKAGE ASSEMBLY – 15”, 9550-79Threaded rod attaches to door. Extends from main arm.
LINKAGE ASSEMBLY – 32”, 9550-79LRThreaded long rod attaches to door. Extends from main arm.Used for reveal 10” to 20”.
TRACKSTRACK 9550-3038Standard non-handed track.
TRACK END CAP 9550-73Black plastic end caps.
ROLLER, 9550-3034Quiet low friction roller assembly.
INSTALLATION ACCESSORIESSPINDLE PLATE – 2 3/4”, 9550-11AHides bottom of motor gearbox. Completes header box. Cutoutallows for motor gearbox shaft. For 2 3/4" offset pivot or butthinge installations.
FILLER PLATE BLANK, 9550-12Completes length of header box. (Specify Length)
MOUNTING PLATE, 9550-18Optional mounting plate for standard hollow metal doorframes. Specify length 33” to 98” maximum.NOTE: The length of a universal 18 plate will need to beordered 3 1/2” longer than the supplied header.
ACCE
SSOR
IES
LCN 9550 SERIES 3077PLCM
30773077L
3077T 77
3038 3034
7979LR
73
11A 12
18
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10114
TABLE OF SIZES Indicates recommended range of door width for operator.
Note: For All Senior Swing SeriesSimultaneous Pair – Width per leaf 30” minimum to 48” maximum
LCN 9550 SERIES
DOOR WIDTH
60"1524mm
96"2438mm
9553
MinimumDoor
Width
HOW-TO-ORDER9550 SERIES OPERATORS
1. SPECIFY HANDRHLH
2. SPECIFY FINISH.Standard Anodized Finish __________Aluminum or Dark Bronze
Operator will be shipped with:-STANDARD MOTOR GEARBOX (SF) (2 ea)-STANDARD CONTROL BOX (SC)-72” METAL COVER (72HL)-REGULAR ARM (2 ea)-2 3/4” PIVOT POINT-MACHINE SCREW PACK
OPERATOR OPTIONSHEADER
HL__ (Specify length 60” to 98”)MOUNTING PLATE
Plate, ____ (Specify Length 30” to 98”) ARM
Standard Arm (2 ea)w/Standard Track (2 ea)Double Egress Includes Standard Arm w/Track (1 ea)& Regular Arm (1 ea)Long Arm (3077L)
SPECIAL TEMPLATEST-_________
ORDE
RINGI
NFOR
MATIO
N
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10115
LCN 9560 SERIES
STANDARD ANODIZED
CUSTOMANODIZED
CUSTOMPAIN
T
FINISH HANDING
HANDED
NON-HANDED
COVER
METAL
ARM FUNCTION
STANDARD (SIN
GLE)
REGULAR (D
OUBLE)
OFFSET PIVOT ARM
CENTER PIVOT ARM
DOUBLEEGRESS (PUSH/PULL
)
MOUNTING
SURFACE MOUNT SIN
GLEDOOR
SURFACE MOUNT SIM
ULTANEOUS PAIR
SURFACE MOUNT IN
DEPENDENT PAIR
CONCEALED SIN
GLEDOOR
CONCEALED IN
DEPENDENT PAIR
CONCEALED SIM
ULTANEOUS PAIR
The 9560 SENIOR SWING by LCN is anADA door operator that is a two-in-one swing door operator. SENIORSWING operators when activated,opens doors automatically forwheelchair access, yet allows formanual operation for regularpedestrian traffic.
Push ‘N Go permits non-switchactivationPower Boost provides additionallatching forceElectromechanical unit withmicroprocessor controlDigital keypad for easy setupMeets International Building Coderequirements and ANSI A156.19UL approved for fire doors
9560 Series is fully compliant with UL325 & UL 1998 and meets theprovisions of ANSI A156.19. The 9560Series is UL listed for fire-ratedapplications. The 9560 Series alsomeets the provisions of the Americanswith Disabilities Act.
9560 series operator is shipped with motor gearboxes, control boxes,arms, header, and mounting hardware. Actuators available separately,see page121.
Independent pair, surface mounted.
Meets ADA requirements (power mode only).
Handed product.
Pull, Push or Double Egress applications available.
72” header length is standard. Specify other length 60” to 98”. Consultfactory regarding this option.
Adjustable hold open period of 1 to 32 seconds in automatic or manualmode.
OPERATOR MOUNTSINDEPENDENT PAIR, SURFACE MOUNT
*PULL SIDEPUSH SIDE
DOUBLE EGRESS
FEATU
RES
*PULL SIDE mount shown
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10116
Butt Hinges should not exceed 5” (127 mm) in width.
Reveal for push installations should not exceed 10” (254 mm) forREGULAR ARM and 20” (508 mm) for LONG ARM.
Reveal for pull installations should not exceed 4” (102 mm).
Reveal for double egress installations should not exceed 4” (102 mm).
Head Frame minimum 1 3/4” (44 mm). Face frame 6 3/4” (171 mm)total operator clearance.
Top Rail minimum 2 3/4” (70 mm).
Opening & Closing Time are variable by adjustments to the electroniccontrol box. Maximum hold open time adjustable up to approximately32 seconds.
System Diagram see “AUTOMATIC OPERATORS” section pages 52-54for typical system wiring and page 55 for electrical data.
Please consult your local SSC representative or LCN for assistance withspecific installations and material requirements.
TOP JAMB INDEPENDENT PAIR(OFFSET PIVOT/BUTT HINGE,CENTER PIVOT, PUSH)MOUNTING
TOP JAMB INDEPENDENT PAIR(OFFSET PIVOT/BUTT HINGE,CENTER PIVOT, PULL)MOUNTING
MAXIMUM OPENINGTemplate allows 90 degree poweropening and 90 degree manualopening.
LCN 9560 SERIES
Special TemplatesCustomized installation templatesor products may be available tosolve unusual applications. Contact LCN for assistance.
MOUN
TINGD
ETAILS
OUTGOING
PUSH ARM ASS'Y
17" From edge of door
OFFSET PIVOT or BUTT HINGES
2 3/4
"70 MM
SWING OPERATOR
8'-0" DOOR OPENING (MAX.)
RE
VE
AL
OUTGOING
SWING OPERATOR
4 1/2
"114 MM
6 3/4
"171 MM
5 3/4
"146 MM
1"25 MM
DOOR
SWING DIRECTION
DOOR FRAME
EXTERIOR
1 7/16
" From top of door
SECONDARY LINK
PULL ARM ASS'Y
OFFSET PIVOT
or BUTT
HINGES
2 3/4
"70 MM
SWING OPERATOR
8'-0" DOOR OPENING (MAX.)
INCOMING
INCOMING
PULL CHANNEL
INTERIOR
17
3/8
"441 MM
1 3/4
"44 MM
11
1/2
"291 MM
SWING OPERATOR
4 1/2
"114 MM
6 3/4
"171 MM
5 3/4
"146 MM
1"25 MM
DOOR
SWING DIRECTION
PULL ARM ASS'Y
INTERIOR
PULL CHANNEL
1 15/16
"49 MM
Butt Hinges should not exceed 5” (127 mm) in width.
Reveal for push installations should not exceed 10” (254 mm) forREGULAR ARM and 20” (508 mm) for LONG ARM.
Reveal for pull installations should not exceed 4” (102 mm).
Reveal for double egress installations should not exceed 4” (102 mm).
Head Frame minimum 1 3/4” (44 mm). Face frame 6 3/4” (171 mm)total operator clearance.
Top Rail minimum 2 3/4” (70 mm).
Opening & Closing Time are variable by adjustments to the electroniccontrol box. Maximum hold open time adjustable up to approximately32 seconds.
System Diagram see “AUTOMATIC OPERATORS” section pages 52-54for typical system wiring and page 55 for electrical data.
Please consult your local SSC representative or LCN for assistance withspecific installations and material requirements.
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10117
TOP JAMB INDEPENDENT PAIR(RH DOUBLE EGRESS)MOUNTING
Consult factory for all balance doorinstallation.
HOLLOW METAL FRAMESuggested Installation
MAXIMUM OPENINGTemplate allows 90 degree poweropening and 90 degree manualopening.
LCN 9560 SERIES
Special TemplatesCustomized installation templatesor products may be available tosolve unusual applications. Contact LCN for assistance.
MOUN
TINGD
ETAILS
SWING OPERATOR
4 1/2
"114 MM
INTERIOR
PUSH ARM ASS'Y
PULL ARM ASS'Y
SWING OPERATOR
SWING OPERATOR
48" DOOR OPENING (MAX.)
2 3/4
"70 MM
48" DOOR OPENING (MAX.)
2 3/4
"70 MM
1 3/4
"44 MM
17" From edge of door
BUTT HINGES
11
1/2
"292 MM
17
3/8
"PULL CHANNEL
SWING OPERATOR
4 1/2
"114 MM
5 3/4
"146 MM
53/
4"
146
MM
6 3/4
"171 MM
SECONDARY LINK DOOR
FRAME
SWING DIRECTION
SWING DIRECTION
DOOR FRAME
DOOR
DOOR
1"25 MM
1"25 MM
23/
18"
FR
OM
BO
TTO
MO
FD
OO
RS
TOP
PULL ARM ASS'Y
PUSH ARM ASS'Y
115
/16"
FR
OM
TOP
OF
DO
OR
PULL CHANNEL
BUTT HINGES
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10118
LCN 9560 SERIES MOTOR GEARBOXMOTOR GEARBOX (STANDARD FORCE) –SENIOR SWING, 9560-3454Driving mechanism for operator. Provides 15lbs opening force.Handed.
MOUNTING BRACKETSMOUNTING BRACKET – 2 3/4”, 9560-275Motor gearbox mounting bracket for 2 3/4" offset pivot or butthinge installations. Front bracket.
REAR MOUNT BRACKET, 9560-3018Motor gearbox mounting bracket. Rear bracket.
ANGLED BRACKET, 9560-334-1Mounting bracket for surface applications.
CONTROL BOXESCONTROL BOX – SENIOR SWING, 9560-3462Electronic controlling device for Senior Swing
HEADERSHEADER, 9560-3572HLStandard, mounting header. Pair door, two operators.Specify length 60”to 98” maximum.
END CAPSHEADER END CAPS, 9560-334End cap with openings for wiring.
END DRESS PLATE, 9560-334-2Metal finish end cap.
ACCE
SSOR
IES 3454
275 3018 344-1
3462
3572HL
334 334-2
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10119
ACCE
SSOR
IES
LCN 9560 SERIES ARMSSTANDARD ARM ASSEMBLY, 9560-3077PLCMHanded arm.
REGULAR ARM ASSEMBLY, 9560-3077Handed arm.
REGULAR LONG ARM ASSEMBLY, 9560-3077LHanded arm.
STANDARD ARM, 9560-3077THanded arm. Track roller not included.
MAIN ARM, 9560 -77Handed arm attaches to motor gearbox
LINKAGE ASSEMBLY – 15”, 9560-79Threaded rod attaches to door. Extends from main arm.
LINKAGE ASSEMBLY – 32”, 9560-79LRThreaded long rod attaches to door. Extends from main arm.Used for reveal 10” to 20”.
TRACKSTRACK 9560-3038Standard non-handed track.
TRACK END CAP 9560-73Black plastic end caps.
ROLLER, 9560-3034Quiet low friction roller assembly.
INSTALLATION ACCESSORIESSPINDLE PLATE – 2 3/4”, 9560-11AHides bottom of motor gearbox. Completes header box. Cutoutallows for motor gearbox shaft. For 2 3/4" offset pivot or butthinge installations.
FILLER PLATE BLANK, 9560-12Completes length of header box. (Specify Length)
MOUNTING PLATE, 9560-18Optional mounting plate for standard hollow metal doorframes. Specify length 33” to 98” maximum.NOTE: The length of a universal 18 plate will need to beordered 3 1/2” longer than the supplied header.
3077PLCM
30773077L
3077T 77
3038 3034
7979LR
73
11A 12
18
LCN CLOSERS121 W. RAILROAD AVE.P.O. BOX 100PRINCETON, IL, USA 61356-0100
PHONE 800-526-2400FAX 800-248-1460www.lcn.ingersollrand.com3/10120
TABLE OF SIZES Indicates recommended range of door width for operator.
Note: For all Senior Swing SeriesIndependent Pair – Width per leaf 30” minimum to 48” maximum
LCN 9560 SERIES
DOOR WIDTH
60"914mm
96"1219mm
9563
MinimumDoor
Width
HOW-TO-ORDER9560 SERIES OPERATORS
1. SPECIFY HANDRHLH
2. SPECIFY FINISH.Standard Anodized Finish _____________Aluminum or Dark Bronze
Operator will be shipped with:-STANDARD MOTOR GEARBOX (SF) (2 ea)-STANDARD CONTROL BOX (SC) (2 ea)-72” METAL COVER (72HL)-REGULAR ARM (2 ea)-2 3/4” PIVOT POINT-MACHINE SCREW PACKUnless options listed below are selected.
OPERATOR OPTIONSHEADER
HL__ (Specify length 60” to 98”)MOUNTING PLATE
Plate, ____ (Specify Length 30” to 98”) ARM
Standard Arm (2 ea)w/Standard Track (2 ea)Double Egress Includes Standard Arm w/Track (1 ea)& Regular Arm (1 ea)Long Arm (3077L)
SPECIAL TEMPLATEST-_________
ORDE
RINGI
NFOR
MATIO
N
*740100*740100
importantthese instructions are presented in step-by-step
sequence. it is very important that installation begins with “1. pre-installation Site and product Check” (page 3) and
continues as directed after each section.
warningalways disconnect main power to the operator prior to
replacing.Control box contains no serviceable parts inside.
Table of Contents
General Information ................................................................................................................................................................................... 1
Electrical Specifications ............................................................................................................................................................................. 2
1 Pre-Installation Site and Product Check ................................................................................................................................................. 2
2 Installation............................................................................................................................................................................................... 3
3 Wiring...................................................................................................................................................................................................... 3
4 Keypad Settings...................................................................................................................................................................................... 7
5 System Test ...........................................................................................................................................................................................11
6 Troubleshooting .................................................................................................................................................................................... 12
7 Release for Service .............................................................................................................................................................................. 13
General Information
The Senior Swing Control Box is for use with the Senior Swing Power Operator System. The system can operate a single door (2810, 9530, and 9540 Series), a simultaneous pair of doors (2850 and 9550 Series), or an independent pair of doors (2860 and 9560 Series).
anSi/BHma a156.19 ComplianceThe Senior S wing Power Operator System is a low energy product and must conform to the latest version of ANSI/BHMA A156.19 (American National Standard for Power Assist and Low Energy Power Operated Doors).
installation instructionsAll installation instructions are valuable references and should be given to the building owner or maintenance supervisor after installation is complete.
The Senior Swing Control Box installation instructions and the manufacturer’s instruction manual accompanying any sensor must be referenced to ensure proper installation, setup, and operation.
2800 Overhead Consealed Series9500 Surface Applied Series
Senior Swing Control Box
Installation Instructions
Electrical Specifications
AC input voltage .................................... 120 VAC
AC fuse .................................................. 120 VAC, 2.5 A time-delay fuse
Motor protection ..................................... Solid state failure detection and shutdown
Activate inputs ....................................... dry NO contacts (close contacts to open door)
Safety inputs .......................................... dry NO contacts (closed contacts indicate an obstruction)
Breakaway input .................................... dry NC contacts (open contacts indicate breakaway)
3-position switch input ........................... dry 3-position switch
Power Boost disable input ..................... dry NO contacts (close contacts to disable Power Boost)
Lock output ............................................ Form C dry relay contacts rated 8 A, 30 VDC maximum
Accessory power output ........................ 24 VAC, 1.5 A (protected by resettable thermal fuse)
Logic power output ................................ 5 V, 50 mA (protected by resettable thermal fuse)
1 Pre-Installation Site and Product Check
importantFactory authorized Door Leaf Size and weight
Type Width per Leaf Maximum Weight per LeafSingle Door 36” to 48” 200 lb.
Simultaneous Pair 30” to 48” 200 lb.
1a All required installation steps listed before “8. Control Box Installation” in the Senior Swing installation instructions should be completed before installing the Senior Swing control box.
1b Check that the control box model (indicated on control box label; Figure 1-1) is correct for the application.
1c Check that the available AC voltage matches the control box voltage requirement (120 VAC).
1d Check that all accessories required for the application are on hand.
Figure 1-1
Label indicates model
CAUTION: 120 VAC2.5 A TIME-DELAY FUSE
WARNING: FOR CONTINUEDPROTECTION AGAINST FIRE,REPLACE ONLY WITH SAMETYPE AND RATING OF FUSE.
COMPANIONMOTOR
COMPANION MASTER
CLOSESPEED
SLOW
FAST
CLOSESPEED
SLOW
FAST
: OPENING SPEED: BACKCHECK SPEED: BACKCHECK POS.: HOLD-OPEN DELAY: LATCH POSITION: AUTO-REV. CLOSING: ELECTRIC LOCK: POWER BOOST: PUSH ‘N’ GO: ALTERNATE ACTION: SAFETY SLOW/STOP: SPECIAL: STATUS ANNOUNCEMENT
SETTING VALUE
DEFAULT
POWERON
UP
DOWN
UP
DOWN
WARNING: ALL SPEEDSETTINGS (OPENING,CLOSING, AND LATCHING)AND HOLD-OPEN TIME-DELAY MUST BE FIELDADJUSTED TO MEETLATEST APPLICABLE ANSI/BHMA STANDARDS.
DMSS #2
APPR
OACH
P5
DMSS #2
SAFE
TYP4
ELEC
TRIC
LOCK
P10
RETR
OFIT
P8
BODY
GUAR
D
P1
ACTIV
ATE
P6
ACTIV
ATE
P7
DMSS #1
APPR
OACH
P3
DMSS #1
SAFE
TYP2SENIOR SWING
710164
elbaecivreS oN
edi snI str aP
2 Installation
To install the Senior Swing Control Box, follow the Senior Swing installation instructions beginning with “8. Control Box Installation” on page 12 of those instructions.
Cautionimproper installation or set up may result in personal
injury or property damage. Follow instructions carefully. For answers to questions, call 1-877-671-7011
3 Wiring• Review the separate wiring diagrams in the accessory instructions so that all wiring can be completed.• See Figure 3-1 for system configuration terminology.• See Figure 3-2, Figure 3-3, and Figure 3-4 for names and locations of control box connectors.• See Figure 3-5 for control box plug and jack descriptions, wiring, and mating cables.• See Figure 3-6 for electric strike locking device sample wiring.• See Figure 3-7 for EL (electric latch retraction) locking device sample wiring.
Cautionwhen joining or separating a plug and receptacle, do not push or pull on wires. this may cause a wire to be pulled loose from a terminal, which may result in a malfunction.
Figure 3-1
Connect operator for second door to controlbox Companion Motor Power receptacle(P5 on control box power board)
Connect masteroperator to controlbox Master MotorPower cable
Connect single dooroperator to MasterMotor Power cablefrom control box
Safetyside
ApproachsideApproach
side
Safetyside
Figure 3-2. Control box power board connectors.
Figure 3-3. Control box logic board connectors.
Figure 3-4. Closeup of control box logic board connectors.
P5
P3 P2 P1 P6 P7
P4 P10P8
DMSS (companion; safety side)
Activate
Activate
DMSS (master; safety side)
DMSS (master; approach side)
DMSS (companion; approach side)
LOGIC BOARD
Companion motor power
(P5)
POWERBOARD
LOGIC BOARD
AC fuse, 120 VAC2.5 A time-delay
Master motorpower
ACpower
Bodyguard (safety side)
Breakaway
3-positionswitch
POWER BOARD
LOGIC BOARD
See Figure 3-4 forcloseup of control
box logic boardconnectors
Locking Interface andPower Boost disable input
RetrofitAccessories
Figure 3-5
Black, 24 VACRed, 24 VACWhite, ActivateGreen, Ground
Black, 24 VACRed, 24 VACWhite, SlowdownGreen, Ground
Black, 24 VACRed, 24 VACWhite, ActivateGreen, Ground
Black, 24 VACWhite, 24 VACYellow, ActivateGray, Ground
Black, 24 VACWhite, 24 VACYellow, ActivateGray, Ground
Blue, Carpet SafetyGray, GroundYellow, ActivateViolet, Slowdown
OrangeBlack
RedGreenBlack
BodyguardJST-type
connector
To DMSS(master;safety side)
To DMSS(master;approach side)
To DMSS(companion;safety side)
To DMSS(companion;approach side)
To existing cable710057 (old partNo. 81276)
To 3-positionswitch (if used)
To motor cable ofcompanion operator(use only for seconddoor of simultaneouspair of doors)
To motor cable ofmaster operator(always use forsingle door)
Bodyguard cableto Bodyguard
sensorCable761468
Cable761464
Cable761464
Cable761469
Cable761465
To locking device(see page 7 forsample wiring)
Cable761466
Cable761463
Retrofitonly
If used
If used
If used
If used
If used
If used
If used
If used
If used
Activate: Initiates a door opening cycle
Bodyguard (master; safety side): Preventsdoor from opening; holds open door in openposition (uses door state data from control boxto ignore door movement while opening/closing)
DMSS (master; safety side): Prevents door fromopening, and slows an opening door
Activate: Initiates a door opening cycle(operates identically to P6 and is provided asa convenience if 2 activations are used)
DMSS (master; approach side): Initiates a dooropening cycle if activated while door is closing
AC Input: 120 VAC
Companion Motor Power: Companion motorpower (use only for second door of simultaneouspair of doors)
Master Motor Power: Master motorpower (use for single door)
3-Position Switch: OFF, AUTO, HOLD
Locking Interface: Power output and relaycontacts for locking devices; Power Boostdisable input
Breakaway: Disables operator inputs whenBreakaway switch is active
DMSS (companion; safety side): Prevents doorfrom opening, and slows an opening door
DMSS (companion; approach side): Initiates adoor opening cycle if activated while door is closing
Retrofit Accessories: Accesses older modelActivate, Slow/Stop, and Carpet Safety inputs
P1
P2
P3
P4
P5
P6
P7
P8
P10
P5
LOG
IC B
OA
RD
POW
ER B
OA
RD
To normally closedBreakaway switchor jumper 81269
White, 24 VACWhite, 24 VAC
Black, Hot ACWhite, Neutral ACGreen, Earth Ground To 120 VAC
Black, 24 VACRed, 24 VACWhite, SlowdownGreen, Ground
DMSSharness761467
Safety
Approach
Safety
Approach
Safe
tyytefaS
hcaorppAAp
proa
ch
on-boardconnector
on-boardconnector
on-boardconnector
on-boardconnector
on-boardconnector
on-boardconnector
on-boardconnector
on-boardconnector
on-boardconnector
on-boardconnector
perm
anen
tco
nnec
tions
perm
anen
tco
nnec
tions
perm
anen
tco
nnec
tions
perm
anen
tco
nnec
tions
DMSSharness761467
Activate cableTo normally open Activate contacts
Activate cableTo normally open Activate contacts
Used only for powered activation device
Used only for powered activation device
Blue, Power Boost disableBlack, GroundViolet, Relay NOGray, Relay COMBrown, Relay NCGreen, 5 V
To normally openPower Boostdisable contacts
Ground
L notE: always wire the locking device to the no (normally open) contact of the control box locking interface and use the keypad to set the EL (electric lock) setting to either Sa (fail safe) or SE (fail secure).
The keypad EL (electric lock) setting is SA (fail safe). When the operator is on, the strike is locked whenthe door is closed and unlocked when the door is opening. When the 3-position switch is set to OFF, thestrike is unlocked.
The keypad EL (electric lock) setting is SE (fail secure). The control box locking relay signals the PS914x 900-2RS. When the operator is on, the EL device is locked when the door is closed and unlocked when thedoor is opening. When the 3-position switch is set to OFF, the EL device is locked.
Figure 3-7. Sample Wiring for a Fail Secure EL (Electric Latch Retraction) Locking Device
Figure 3-6. Sample Wiring for a Fail Safe Electric Strike Locking Device
Cable 761465 to Senior Swing control box lockinginterface receptacle (P10)
Fail safeelectricstrike
Rectifier(for DCstrikes)
Senior Swingcontrol box
EL device
Gray (COM)
Violet (NO)
Cable 761465 toSenior Swing control box locking
interface receptacle (P10)
Senior Swing control box
Control box lock supply rating: 24 VAC, 1.5 A
WhiteWhite
Gray (COM)Violet (NO)
White
White
Black
Red
Cut connector off rectifier, thenconnect using wire nuts
When using an EL device such as EL33A, EL99, etc:Use 12 AWG stranded wire for outputs 01 and 02between PS914 and EL device (200’ run maximum).
SC I1 01 I2 02 GND
Von DuprinPS914 x 900-2RS
4 Keypad Settings
Settings (except for close speed) for the Senior Swing Power Operator System are changed using keypad pushbuttons and an alphanumeric display on the control box (Figure 4-1 and Figure 4-2). Close speed is changed using dials on the control box (Figure 4-1).
See page 9 and page 10 for directions for changing the values of settings.
Cautionadjust the operator for the slowest operation practical in accordance with the latest revisions of americans with
Disabilities act, anSi/BHma a156.19 (american national Standard for power assist and Low Energy power operated Doors), and
local codes.
Figure 4-1. Control Box Panel with Keypad
Figure 4-2. Closeup of Control Box Keypad
SETTING VALUE
NWODNWOD
PUPU
DEFAULT
POWERON
Setting display
Reset to defaultvalues pushbutton
Value selectionpushbuttons
Setting selectionpushbuttons
: OPENING SPEED: BACKCHECK SPEED: BACKCHECK POS.: HOLD-OPEN DELAY: LATCH POSITION: AUTO-REV. CLOSING: ELECTRIC LOCK: POWER BOOST: PUSH ‘N’ GO: ALTERNATE ACTION: SAFETY SLOW/STOP: SPECIAL: STATUS ANNOUNCEMENT
Value display
KeypadClose speed dials
CAUTION: 120 VAC2.5 A TIME-DELAY FUSE
WARNING: FOR CONTINUEDPROTECTION AGAINST FIRE,REPLACE ONLY WITH SAMETYPE AND RATING OF FUSE.
COMPANIONMOTOR
COMPANION MASTER
CLOSESPEED
SLOW
FAST
CLOSESPEED
SLOW
FAST
: OPENING SPEED: BACKCHECK SPEED: BACKCHECK POS.: HOLD-OPEN DELAY: LATCH POSITION: AUTO-REV. CLOSING: ELECTRIC LOCK: POWER BOOST: PUSH ‘N’ GO: ALTERNATE ACTION: SAFETY SLOW/STOP: SPECIAL: STATUS ANNOUNCEMENT
SETTING VALUE
DEFAULT
POWERON
UP
DOWN
UP
DOWN
WARNING: ALL SPEEDSETTINGS (OPENING,CLOSING, AND LATCHING)AND HOLD-OPEN TIME-DELAY MUST BE FIELDADJUSTED TO MEETLATEST APPLICABLE ANSI/BHMA STANDARDS.
DMSS #2
APPR
OACH
P5
DMSS #2
SAFE
TYP4
ELEC
TRIC
LOCK
P10
RETR
OFIT
P8
BODY
GUAR
D
P1
ACTIV
ATE
P6
ACTIV
ATE
P7
DMSS #1
APPR
OACH
P3
DMSS #1
SAFE
TYP2SENIOR SWING
710164
elbaecivreS oN
edi snI str aP
warningKEEp HanDS, CLotHing, wirES, tooLS, LaDDErS,
EtC. awaY From tHE Door wHEn tHE opErator iS initiaLLY turnED on.
See Figure 4-3 for definitions of the positions of the door throughout the opening and closing cycle.
See Table 4-1 for explanations of the keypad settings.
to change setting values:1. Set the 3-position switch, if used, to OFF.
2. Apply AC power. The POWER light will illuminate and the display will remain blank.
3. Press any two pushbuttons at the same time for 1 second to turn on the keypad. The display will illuminate.
4. Press the UP or DOWN setting selection pushbutton to select the desired setting. The setting is shown in the SETTING display, and the current value for that setting is shown in the VALUE display.
5. Press the UP or DOWN value selection pushbutton to select the desired value for the displayed setting. The value for the setting is indicated in the VALUE display.
6. The keypad will automatically turn off after 5 minutes of inactivity.
to reset all values to default (default values are listed in table 4-1 under “Selectable Values”):1. Set the 3-position switch, if used, to OFF.
2. Apply AC power. The POWER light will illuminate, and the display will remain blank.
3. Press any two pushbuttons at the same time for 1 second to turn on the keypad. The display will illuminate.
4. Press the DEFAULT pushbutton for 4 seconds.
5. The values are set to default, and the display will indicate the opening speed setting and value.
6. The keypad will automatically turn off after 5 minutes of inactivity.
Back check speedBack check position
Openingspeed
Closingspeed
Latch positionDeceleration to fully
closed position
Figure 4-3. Door Position Definitions
Safety side Door mounted Safety Sensor (DmSS) disable featurepurpose:Deactivate the Door Mounted Safety Sensor (DMSS) on safety side of door to eliminate nuisance detection of a wall or guard rail.
1. Install control box, all door hardware and safety devices per their instructions.
2. Setup DMSS sensors in accordance with ANSI standard 156.10.
3. Use keypad to set SAFETY SLOW/STOP (SS) value to STOP (SP).
4. Use keypad to set SLOWDOWN DISABLE (SD) value to 85.
5. Activate door opening cycle. If door does not open fully, use keypad to reduce SD value from 85 in 5 degree increments.
6. Repeat Step 5 until door opens fully.
7. Perform a complete system test as described in the section 5.
Frame
Wall
rosn
eS ev
itcA(85 degrees or less)
Safe
ty s
ide
DM
SS S
enso
rD
oor
DM
SS S
enso
r
table 4-1. Control Box Settings and Selectable Values
Setting Setting Display Selectable Values Values as Displayed
Description
Opening Speed 01 = slow 02 = medium
03 = fast (default = 01)
Controls opening speed of any normal weight and size door
Back Check Speed 01 = 1 door 02 = 2 doors (default = 01)
Controls speed of door near full open position to prevent door slamming open
Back Check Position 45-80 degrees (default = 70)
Approximate angle at which door begins to decelerate near the full open position
Hold Open Delay 01-32 seconds (default = 05)
Amount of time (in seconds) door remains fully open following an activate signal
Latch Position 00-23 degrees (default = 13)
Approximate angle at which door begins to decelerate near the full closed position
Auto Reverse Closing off, on (default = off)
When on, door will re-open upon hitting an obstruction
Electric Lock
off SA = fail safe
SE = fail secure (default = off)
To turn on, set to SA (fail safe) or SE (fail secure) to match locking device connected to control box locking interface receptacle (P10); when on, causes a 1 second delay between activate signal and door opening to allow time for most electric locks to disengage before operator opens door
Power Boost
off 5 seconds continuous
(default = off)
When on, increases closing force of door from 9 lbs to 18 lbs to close door against high winds or stack pressure; turns on for 5 seconds or continuously after door reaches latch position during closing cycle; disabled by Power Boost disable input
Push ‘N’ Go
off, on, fd (default = off)
When set to On or Fd, pushing door open 5 degrees causes operator to open door remainder of way and hold open. Hold open time is same as hd setting when set to On. Hold open time is 1 second when set to Fd.
Alternate Activate off, on (default = off)
When on, door stays open until a second activate signal is received.
Safety Slow/Stop
slow, stop (default = slow)
Determines response to a DMSS on the safety side of the door; if SL (slow), door goes to back check speed; if SP (stop), door stops for 5 seconds, then continues opening at back check speed
Special off 30-85
(default = off)
Deactivate the Door Mounted Safety Sensor (DMSS) on safety side of door to eliminate nuisance detection of a wall or guard rail.
Status AnnouncementReserved Reserved
Reserved
5 System Test
warningKEEp HanDS, CLotHing, wirES, tooLS, LaDDErS,
EtC. awaY From tHE Door wHEn tHE opErator iS initiaLLY turnED on.
If control box does not operate as expected during system test, see section 6 for troubleshooting tips.
5a With the door closed, set the 3-position switch, if used, to AUTO and turn on all AC power. For applications using companion door, try to get both doors to open same amount of degrees before hitting hard stop (either internal gearbox stop or rubber bumper on wall).
5b Activate the operator using an activation device. The operator should perform one sizing cycle.Sizing cycle: Occurs when the door is activated for the first time after power is turned on. During the sizing cycle, the door opens and closes once.
if the door sizes properly, go to step No. 5.3.
if the door does not open at all during the sizing cycle:• Check that the 3-position switch, if used, is not set to OFF.• Check door for binds and proper mechanical installation.• Verify that all safety sensors are inactive.• If an electromechanical lock is used, check that the lock disengages before the operator opens the door.• Verify that the Breakaway switch, if used, is connected to NC contacts. If a Breakaway switch is not used, check that the Breakaway
cable coming from the control box logic board is jumpered (jumper part No. 761492-00).• Check fuse, wiring, and connections.• Adjust the operator as follows and check door operation:
Opening speed: ..........................01 Back check speed: ......................01 for one door, 02 for two doors Hold open delay: .........................05 Back check position: ...................75 Latch position: .............................10 Close speed: ...............................medium Electric lock: ................................SA (fail safe) or SE (fail secure) to match lock
if the door does not open fully during the sizing cycle, check door for binds, obstructions, or items that could activate safety sensors.
5c After the sizing cycle is complete and the door is closed, apply a maintained activation signal and check that the door remains open while the activation signal is applied. Then release the activate signal and verify door closes after the open time delay expires.
5d To check the function of the door safety device:1. Activate the door and then activate the approach side safety device while the door is open. The door should not close while the
safety device is activated. Next, deactivate the safety device. The door should close after the hold open time delay expires.
2. With the door closed, activate the safety side safety device, then activate the door. The door should not open while the safety device is activated. Next, deactivate the safety device. The door should open when activated.
5e Set the 3-position switch, if used, to HOLD. Verify that the door opens and stays open.
5f Set the 3-position switch, if used, to OFF. Verify that the door closes. Verify that an activate signal does not open the door.
5g If a Breakaway switch is connected, set the 3-position switch, if used, to AUTO, then break open the door. Verify that an activate signal does not cause the door to move. Re-latch the door after testing.
5h Do not release the system for service until it is operating properly.
6 Troubleshooting6a Identify all switch and sensor inputs that are currently active:1. Remove breakaway jumper to enter diagnostic mode. L note: when in diagnostic mode, controller will not open door.
2. Keypad display shows each active input signal for 1 second. See table below:
(Key switch) set to Auto OR is not present ......................... SA80 (Key switch) set to OFF ...................................................... SA81 (Key switch) set to HOLD ................................................... SA82 (Activate) input is ON .......................................................... SA83 (DMSS approach) activate input is ON ............................... SA84 (DMSS safety) slowdown input is ON ................................. SA85 (Carpet Safety) input is ON ................................................ SA86 (Bodyguard) input is ON ..................................................... SA87 (Power Boost Disable) input is ON ..................................... SA88
For example, if key switch is set to Auto, Activate button is pressed, and DMSS sees something on the safety side, then display will repeat the sequence SA80, SA83, SA85 continuously until breakaway jumper is replaced.
3. After completing diagnostics, reinstall breakaway jumper for normal operation.
© Allegion 2014Printed in U.S.A.
740100 Rev. 02/14-h
6b If control box does not function and the error message Er## flashes on the control box Setting and Value displays, turn AC power off and on to reset the control box. The following are common errors and suggested fixes:ER 06: Master motor problem - verify master motor cable is connected to motor. ER 14: Companion door added to a setup that was already sized - turn AC power off, then on and resize with both doors connected.
If problem cannot be corrected by using suggested fixes, contact 1-877-671-7011.
7 Release for Service7a Remove all tools, installation equipment, and debris from the vicinity of the door.
7b Install all safety, traffic control, and instruction decals on the door as required by the latest revision of ANSI/BHMA A156.19. This is very important! Failure to do this leaves the installer LIABLE for any accident that might occur. This must be done!
7c Verbally instruct the owner or person in charge of the proper operation of the door.
7d Instruct the owner or person in charge to routinely inspect the door for the following:• Visible damage• Developing problems• Minor preventive maintenance
7e Instruct the owner or person in charge who and where to call for service when required.
importantMake sure to install all safety, traffic control, and
instruction decals on the door as required.
Customer Service1-877-671-7011 www.allegion.com/us
Page 6 of 18 740132-00(0)
3. SURFACE HEADER INSTALLATION
Figure 3-1
3.1. For a header with two operators (for a simultaneously operated pair of doors), designateone end of the header as the companion operator end. (It does not matter which end.)
3.2. Refer to Figure 3-1 and step 3.3 and prepare wire access holes appropriate for theapplication in the header using template 91194-684. Be sure to position edge “A” oftemplate 91194-684 as shown in Figure 3-1.
20”
20”
Edge “A”
Edge “A”Double operatorholes on top
COMPANION END
COMPANION END
20”
20”
Edge “A”
Edge “A”
Back of header
Back of header
Double operatorholes on back
COMPANION END
COMPANION END
Single operator, holes on backSingle operator, holes on top
Edge “A”
3.3. Install horizontal mounting brackets on the header per the instructions supplied with thebrackets (Figure 3-2). Make sure the horizontal mounting brackets are oriented so the wireaccess holes in the header (see step 3.2) face up or face the door and, for single operatorheaders, the operator brackets inside the header are near the hinge side of the opening.
Edge “A”
Edge “A”Back of headerBack of header
Figure 3-2
Operator brackets(inside header)Horizontal
mountingbracket
Horizontalmountingbracket
Operator brackets(inside header)