lcd 400 - mesteksa.commesteksa.com/fileuploads/literature/rbi water heaters/lcd series... · [27.3...
TRANSCRIPT
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
LCD 400Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SLCD-400-6The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-15-E
LCD 400 model water heater not available for sale in the U.S. market due to DOE regulations.
14 5/16 in [36.4 cm]
28 5/8 in [72.7 cm]
4 7/16 in [11.3 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø6"
8 1/4 in [20.9 cm] 1 1/2 in
[3.8 cm]
6 in [15.2 cm]
33 1/16 in [84.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE
4 7/8 in [12.4 cm]
15 5/16 in [38.9 cm]
Ø1 1/2" WATER(2 PLCS.)
Ø3/4"NAT & LP
29 5/16 in [74.4 cm]
37 7/8 in [96.1 cm]
26 9/16 in [67.4 cm]
6 1/16 in [15.4 cm]
10 3/4 in [27.3 cm]
5 in [12.7 cm]
OPERATING STATUS
33 11/16 in [85.6 cm]
35 3/16 in [89.4 cm]
19 1/16 in [19.1 cm]
12 15/16 in [12.9 cm]
14 1/16 in [14.1 cm]
14 5/16 in [36.4 cm]
28 5/8 in [72.7 cm]
4 7/16 in [11.3 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø6"
8 1/4 in [20.9 cm] 1 1/2 in
[3.8 cm]
6 in [15.2 cm]
33 1/16 in [84.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE
4 7/8 in [12.4 cm]
15 5/16 in [38.9 cm]
Ø1 1/2" WATER(2 PLCS.)
Ø3/4"NAT & LP
29 5/16 in [74.4 cm]
37 7/8 in [96.1 cm]
26 9/16 in [67.4 cm]
6 1/16 in [15.4 cm]
10 3/4 in [27.3 cm]
5 in [12.7 cm]
OPERATING STATUS
33 11/16 in [85.6 cm]
35 3/16 in [89.4 cm]
19 1/16 in [19.1 cm]
12 15/16 in [12.9 cm]
14 1/16 in [14.1 cm]
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
LCD 400Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 3.8*
Input BTU/hr. 399,000 / 117 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 327,180 / 96 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 402 lbs. / 183 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell VR8305Q 3/4" Pilot Valve Honeywell VR8205Q
Firing Valve Honeywell B200T1025 3/4" Air Switch Cleveland RSS-495
Ignition Control UTC 1003-61A Blower Motor 1/5 hp - FLA 3.0
Operating Control (LB/LW) Jumo Relief Valve - LW 3/4" x 3/4" set @ 125 psi
High Limit (LB/LW) Jumo Relief Valve - LB 3/4" x 3/4" set @ 50 psi
Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 40.1 Sq. Ft. / 3.73 Sq. M. Design Data Max. 160 psig & 250°F
Water Volume 1.4 gal / 5.3 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP15°F / 8.3°C 20°F / 11.1°C 25°F / 13.9°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
43.7 2.8 0.70 2.1 32.8 2.1 0.41 1.2 26.2 1.7 0.27 0.8
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SLCD-400-6
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
982 3717 655 2478 491 1859 393 1487 327 1239 281 1062
The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
LCD 600Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SLCD-600-6The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-16-E
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø8"
2 3/4 in [7.0 cm]4 7/16 in
[11.3 cm]
35 1/8 in [89.2 cm]
17 9/16 in [44.6 cm]
9 13/16 in [25.0 cm]
7 in [17.8 cm]
33 1/16 in [84.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE
4 7/8 in [12.4 cm]
15 5/16 in [38.9 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1"NAT & LP
29 5/16 in [74.4 cm]
37 7/8 in [96.1 cm]
26 9/16 in [67.4 cm]
6 1/16 in [15.4 cm]
11 1/8 in [28.2 cm]
5 in [12.7 cm]
OPERATING STATUS
40 3/16 in [102.1 cm]
35 3/16 in [89.4 cm]
19 1/16 in [48.5 cm]
12 15/16 in [32.9 cm]
17 1/4 in [43.9 cm]
CENTER OFGRAVITY
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø8"
2 3/4 in [7.0 cm]4 7/16 in
[11.3 cm]
35 1/8 in [89.2 cm]
17 9/16 in [44.6 cm]
9 13/16 in [25.0 cm]
7 in [17.8 cm]
33 1/16 in [84.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE
4 7/8 in [12.4 cm]
15 5/16 in [38.9 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1"NAT & LP
29 5/16 in [74.4 cm]
37 7/8 in [96.1 cm]
26 9/16 in [67.4 cm]
6 1/16 in [15.4 cm]
11 1/8 in [28.2 cm]
5 in [12.7 cm]
OPERATING STATUS
40 3/16 in [102.1 cm]
35 3/16 in [89.4 cm]
19 1/16 in [48.5 cm]
12 15/16 in [32.9 cm]
17 1/4 in [43.9 cm]
CENTER OFGRAVITY
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
LCD 600Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 3.8*
Input BTU/hr. 600,000 / 176 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 492,000 / 144 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 523 lbs. / 237 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944B 1" Pilot Valve Honeywell VR8205Q
Firing Valve Honeywell B200T1033 1" Air Switch Cleveland RSS-495
Safety Valve Honeywell V48A 1" Blower Motor 1/4 hp - FLA 3.0
Ignition Control UTC 1003-61A Relief Valve - LW 3/4" x 3/4" set @ 125 psi
Operating Control (LB/LW) Jumo Relief Valve - LB 3/4" x 3/4" set @ 50 psi
High Limit (LB/LW) Jumo Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 51.3 Sq. Ft. / 4.77 Sq. M. Design Data Max. 160 psig & 250°F
Water Volume 1.6 gal / 5.9 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP15°F / 8.3°C 20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
65.6 4.1 1.84 5.4 49.2 3.1 1.08 3.2 39.4 2.5 0.71 2.1 32.8 2.1 0.51 1.5
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SLCD-600-6
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
1477 5582 984 3721 738 2791 591 2233 492 1861 422 1595
The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
LCD 750Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SLCD-750-6The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-17-E
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø8"[20.32 cm]
4 7/16 in [11.3 cm]
41 5/8 in [105.7 cm]
20 13/16 in [52.9 cm]
2 3/4 in [7.0 cm]
10 1/4 in [26.1 cm]
8 in [20.3 cm] REAR FLUE OUTLET
(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
6 1/4 in [15.9 cm]
15 5/16 in [38.9 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1"NAT & LP
29 5/16 in [74.4 cm]
37 7/8 in [96.1 cm]
26 9/16 in [67.4 cm]
6 1/16 in [15.4 cm] 11 1/8 in
[28.2 cm]
5 in [12.7 cm]
15 15/16 in [40.5 cm]
11 in [28.0 cm]
OPERATING STATUS
46 11/16 in [118.7 cm]
35 3/16 in [89.42 cm] 31 7/8 in
[80.9 cm]19 1/16 in [48.48 cm]
20 7/16 in [51.97 cm]
CENTER OFGRAVITY
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø8"[20.32 cm]
4 7/16 in [11.3 cm]
41 5/8 in [105.7 cm]
20 13/16 in [52.9 cm]
2 3/4 in [7.0 cm]
10 1/4 in [26.1 cm]
8 in [20.3 cm] REAR FLUE OUTLET
(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
6 1/4 in [15.9 cm]
15 5/16 in [38.9 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1"NAT & LP
29 5/16 in [74.4 cm]
37 7/8 in [96.1 cm]
26 9/16 in [67.4 cm]
6 1/16 in [15.4 cm] 11 1/8 in
[28.2 cm]
5 in [12.7 cm]
15 15/16 in [40.5 cm]
11 in [28.0 cm]
OPERATING STATUS
46 11/16 in [118.7 cm]
35 3/16 in [89.42 cm] 31 7/8 in
[80.9 cm]19 1/16 in [48.48 cm]
20 7/16 in [51.97 cm]
CENTER OFGRAVITY
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
LCD 750Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 5.9*
Input BTU/hr. 750,000 / 220 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 615,000 / 180 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 554 lbs. / 252 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944B 1" Pilot Valve Honeywell VR8205Q
Firing Valve Honeywell B200T1033 1" Air Switch Cleveland RSS-495
Safety Valve Honeywell V48A 1" Blower Motor 1/4 hp - FLA 5.1
Ignition Control UTC 1003-61A Relief Valve - LW 3/4" x 3/4" set @ 125 psi
Operating Control (LB/LW) Jumo Relief Valve - LB 3/4" x 3/4" set @ 50 psi
High Limit (LB/LW) Jumo Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 61.7 Sq. Ft. / 5.73 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 1.7 gal / 6.5 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
61.5 3.9 1.95 5.7 49.2 3.1 1.29 3.8 41.0 2.6 0.92 2.7 35.1 2.2 0.69 2.0
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SLCD-750-6
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
1846 6977 1230 4651 923 3488 738 2791 615 2326 527 1993
The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
LCD 1050Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SLCD-1050-6The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-19-E
29 3/16 in [74.1 cm]
58 3/8 in [148.3 cm]
4 3/16 in [10.7 cm]
8 7/8 in [22.5 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø10 in [Ø25.40 cm]
2 3/4 in [7.0 cm]
9 13/16 in [25.0 cm]
10 in [25.4 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/4"NAT & LP
29 5/16 in [74.4 cm]6 5/16 in
[16.0 cm]5 in
[12.7 cm]
37 15/16 in [96.4 cm]
26 5/8 in [67.7 cm]
6 1/16 in [15.4 cm]
11 1/8 in [28.2 cm]
20 7/8 in [53.1 cm]
11 in [27.9 cm]
OPERATING STATUS
63 7/16 in [161.2 cm]
31 5/8 in [80.3 cm]35 3/16 in
[89.42 cm]
12 15/16 in [32.86 cm]
19 1/16 in [48.48 cm]
28 11/16 in [72.89 cm]
CENTER OFGRAVITY
29 3/16 in [74.1 cm]
58 3/8 in [148.3 cm]
4 3/16 in [10.7 cm]
8 7/8 in [22.5 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø10 in [Ø25.40 cm]
2 3/4 in [7.0 cm]
9 13/16 in [25.0 cm]
10 in [25.4 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/4"NAT & LP
29 5/16 in [74.4 cm]6 5/16 in
[16.0 cm]5 in
[12.7 cm]
37 15/16 in [96.4 cm]
26 5/8 in [67.7 cm]
6 1/16 in [15.4 cm]
11 1/8 in [28.2 cm]
20 7/8 in [53.1 cm]
11 in [27.9 cm]
OPERATING STATUS
63 7/16 in [161.2 cm]
31 5/8 in [80.3 cm]35 3/16 in
[89.42 cm]
12 15/16 in [32.86 cm]
19 1/16 in [48.48 cm]
28 11/16 in [72.89 cm]
CENTER OFGRAVITY
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
LCD 1050Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 11.0*
Input BTU/hr. 1,050,000 / 308 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 861,000 / 252 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 752 lbs. / 341 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944B 1-1/4" Pilot Valve Honeywell VR8205Q
Firing Valve Honeywell B200T1041 1-1/4" Air Switch Cleveland RSS-495
Safety Valve Honeywell V48A 1-1/4" Blower Motor 1/4 hp - FLA 10.2
Ignition Control UTC 1003-61A Relief Valve - LW 3/4" x 3/4" set @ 125 psi
Operating Control (LB/LW) Jumo Relief Valve - LB 3/4" x 3/4" set @ 50 psi
High Limit (LB/LW) Jumo Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 88.1 Sq. Ft. / 8.18 Sq. M. Design Data Max. 160 psig & 250°F
Water Volume 2.1 gal / 7.8 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
86.1 5.4 5.16 15.2 68.9 4.3 3.41 10.1 57.4 3.6 2.44 7.2 49.2 3.1 1.83 5.4
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SLCD-1050-6
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
2587 9780 1725 6520 1294 4890 1035 3912 862 3260 739 2794
The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
LCD 1200Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SLCD-1200-6The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-20-E
29 7/16 in [74.7 cm]
7 1/2 in [19.1 cm]
Ø12 in [Ø30.5 cm]
9 13/16 in [25.0 cm]
2 3/4 in [7.0 cm]
13 3/8 in [34.0 cm]4 3/16 in
[10.7 cm]
71 3/8 in [181.3 cm]
35 11/16 in [90.6 cm]
12 in [30.5 cm] REAR FLUE OUTLET
(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
OPERATING STATUS
27 3/8 in [69.6 cm]
11 in [27.9 cm]
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/4"NAT & LP
29 5/16 in [74.4 cm]7 13/16 in
[19.8 cm]5 in
[12.7 cm]
37 15/16 in [96.4 cm]
26 5/8 in [67.7 cm]
6 1/16 in [15.4 cm]
11 1/8 in [28.2 cm]
76 7/16 in [194.2 cm]
30 in [76.2 cm]35 3/16 in
[89.42 cm]
35 1/16 in [89.11 cm]
19 1/16 in [48.48 cm]
12 15/16 in [32.86 cm]
CENTER OFGRAVITY
29 7/16 in [74.7 cm]
7 1/2 in [19.1 cm]
Ø12 in [Ø30.5 cm]
9 13/16 in [25.0 cm]
2 3/4 in [7.0 cm]
13 3/8 in [34.0 cm]4 3/16 in
[10.7 cm]
71 3/8 in [181.3 cm]
35 11/16 in [90.6 cm]
12 in [30.5 cm] REAR FLUE OUTLET
(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
OPERATING STATUS
27 3/8 in [69.6 cm]
11 in [27.9 cm]
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/4"NAT & LP
29 5/16 in [74.4 cm]7 13/16 in
[19.8 cm]5 in
[12.7 cm]
37 15/16 in [96.4 cm]
26 5/8 in [67.7 cm]
6 1/16 in [15.4 cm]
11 1/8 in [28.2 cm]
76 7/16 in [194.2 cm]
30 in [76.2 cm]35 3/16 in
[89.42 cm]
35 1/16 in [89.11 cm]
19 1/16 in [48.48 cm]
12 15/16 in [32.86 cm]
CENTER OFGRAVITY
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
LCD 1200Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 11.0*
Input BTU/hr. 1,200,000 / 352 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 984,000 / 288 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 781 lbs. / 355 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944B 1-1/4" Pilot Valve Honeywell VR8205Q
Firing Valve Honeywell B200T1041 1-1/4" Air Switch Cleveland RSS-495
Safety Valve Honeywell V48A 1-1/4" Blower Motor (2) 1/4 hp - FLA 10.2
Ignition Control UTC 1003-61A Relief Valve - LW 3/4" x 3/4" set @ 125 psi
Operating Control (LB/LW) Jumo Relief Valve - LB 1" x 1-1/4" set @ 50 psi
High Limit (LB/LW) Jumo Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 109.7 Sq. Ft. / 10.19 Sq. M. Design Data Max. 160 psig & 250°F
Water Volume 2.3 gal / 8.8 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
98.4† 6.2† 8.14 24.0 78.7 5.0 5.38 15.9 65.6 4.1 3.84 11.3 56.2 3.5 2.89 8.5
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SLCD-1200-6
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
2960 11190 1974 7460 1480 5595 1184 4476 987 3730 846 3197
The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
† Flow exceeds recommended maximum use a greater temperature rise or consult manufacturer. Cupronickel heat exchanger should be considered.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
LCD 1480Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SLCD-1480-6The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-21-E
12 in [30.5 cm]
15 in [38.10 cm]
4 1/8 in [10.48 cm]
35 11/16 in [90.6 cm]
71 3/8 in [181.3 cm]
4 3/16 in [10.7 cm]
13 3/8 in [34.0 cm]
2 3/4 in [7.0 cm]
5 3/16 in [13.2 cm]
Ø12 in [Ø30.5 cm]
7 1/2 in [19.1 cm]
29 5/8 in [75.2 cm]
12 in [30.5 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
OPERATING STATUS
27 3/8 in [69.6 cm]
11 in [27.9 cm]
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/2"NAT & LP
29 5/16 in [74.4 cm]7 13/16 in
[19.8 cm]5 in
[12.7 cm]
37 15/16 in [96.4 cm]
26 5/8 in [67.7 cm]
76 7/16 in [194.2 cm]
35 3/16 in [89.42 cm] 30 1/8 in
[76.5 cm]19 1/16 in [48.48 cm]
12 15/16 in [32.86 cm]
35 1/16 in [89.11 cm]
CENTER OFGRAVITY
12 in [30.5 cm]
15 in [38.10 cm]
4 1/8 in [10.48 cm]
35 11/16 in [90.6 cm]
71 3/8 in [181.3 cm]
4 3/16 in [10.7 cm]
13 3/8 in [34.0 cm]
2 3/4 in [7.0 cm]
5 3/16 in [13.2 cm]
Ø12 in [Ø30.5 cm]
7 1/2 in [19.1 cm]
29 5/8 in [75.2 cm]
12 in [30.5 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
OPERATING STATUS
27 3/8 in [69.6 cm]
11 in [27.9 cm]
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/2"NAT & LP
29 5/16 in [74.4 cm]7 13/16 in
[19.8 cm]5 in
[12.7 cm]
37 15/16 in [96.4 cm]
26 5/8 in [67.7 cm]
76 7/16 in [194.2 cm]
35 3/16 in [89.42 cm] 30 1/8 in
[76.5 cm]19 1/16 in [48.48 cm]
12 15/16 in [32.86 cm]
35 1/16 in [89.11 cm]
CENTER OFGRAVITY
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
LCD 1480Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 11.0*
Input BTU/hr. 1,480,000 / 434 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 1,213,600 / 356 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 830 lbs. / 377 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944B 1-1/2" Pilot Valve Honeywell VR8205Q
Firing Valve Honeywell B200T1058 1-1/2" Air Switch Cleveland RSS-495
Safety Valve Honeywell V48A 1-1/2" Blower Motor (2) 1/4 hp - FLA 10.2
Ignition Control UTC 1003-61A Relief Valve - LW 3/4" x 3/4" set @ 125 psi
Operating Control (LB/LW) Jumo Relief Valve - LB 1" x 1-1/4" set @ 50 psi
High Limit (LB/LW) Jumo Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 137 Sq. Ft. / 12.73 Sq. M. Design Data Max. 160 psig & 250°F
Water Volume 4.8 gal / 18.2 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
121.4† 7.7† 7.94 23.4 97.1 6.1 5.25 15.5 80.9 5.1 3.75 11.0 69.3 4.4 2.82 8.3
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SLCD-1480-6
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
3656 13818 2437 9212 1828 6909 1462 5527 1219 4606 1044 3948
The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
† Flow exceeds recommended maximum use a greater temperature rise or consult manufacturer. Cupronickel heat exchanger should be considered.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
LCD 1650Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SLCD-1650-7The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-22-F
38 15/16 in [98.9 cm]
77 7/8 in [197.8 cm]
4 3/16 in [10.7 cm]
16 7/8 in [42.9 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø12 in [Ø30.5 cm]
5 3/16 in [13.2 cm] 2 3/4 in
[7.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
30 5/8 in [77.9 cm]
11 in [27.9 cm]
OPERATING STATUS
15 in [38.1 cm]
4 1/8 in [10.5 cm]
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/2"NAT & LP
29 5/16 in [74.4 cm]7 13/16 in
[19.8 cm]
5 in [12.7 cm]
37 15/16 in [96.4 cm]
26 5/8 in [67.7 cm]
82 15/16 in [210.7 cm]
30 in [76.2 cm]
35 3/16 in [89.42 cm]
31 15/16 in [81.1 cm]
14 in[35.6 cm]
38 5/16 in [97.23 cm]
19 1/16 in [48.48 cm]
12 15/16 in [32.86 cm]
50 5/16 in [127.72 cm]
38 15/16 in [98.9 cm]
77 7/8 in [197.8 cm]
4 3/16 in [10.7 cm]
16 7/8 in [42.9 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø12 in [Ø30.5 cm]
5 3/16 in [13.2 cm] 2 3/4 in
[7.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
30 5/8 in [77.9 cm]
11 in [27.9 cm]
OPERATING STATUS
15 in [38.1 cm]
4 1/8 in [10.5 cm]
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/2"NAT & LP
29 5/16 in [74.4 cm]7 13/16 in
[19.8 cm]
5 in [12.7 cm]
37 15/16 in [96.4 cm]
26 5/8 in [67.7 cm]
82 15/16 in [210.7 cm]
30 in [76.2 cm]
35 3/16 in [89.42 cm]
31 15/16 in [81.1 cm]
14 in[35.6 cm]
38 5/16 in [97.23 cm]
19 1/16 in [48.48 cm]
12 15/16 in [32.86 cm]
50 5/16 in [127.72 cm]
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
LCD 1650Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 11.0*
Input BTU/hr. 1,650,000 / 483 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 1,353,000 / 396 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 906 lbs. / 411 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944B 1-1/2" Pilot Valve Honeywell VR8205Q
Firing Valve Honeywell B200T1058 1-1/2" Air Switch Cleveland RSS-495
Safety Valve Honeywell V48A 1-1/2" Blower Motor (2) 1/4 hp - FLA 10.2
Ignition Control UTC 1003-61A Relief Valve - LW 3/4" x 3/4" set @ 125 psi
Operating Control (LB/LW) Jumo Relief Valve - LB 1" x 1- 1/4" set @ 50 psi
High Limit (LB/LW) Jumo Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 149 Sq. Ft. / 13.84 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 4.9 gal / 18.6 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
108.2 6.8 7.02 20.7 90.2 5.7 5.01 14.8 77.3 4.9 3.77 11.1
* Add circulator amps.** For incoming gas pressures lower than 7" WC natural or 11" WC propane, consult factory.
SLCD-1650-7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
4075 15405 2717 10270 2038 7703 1630 6162 1358 5135 1164 4402
The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
LCD 1970Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SLCD-1970-7The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-23-F
Ø12 in [Ø30.5 cm]
7 1/2 in [19.1 cm]
29 5/8 in [75.2 cm]
26 3/8 in [67.0 cm]4 3/16 in
[10.7 cm]
97 3/8 in [247.3 cm]48 11/16 in
[123.7 cm]
2 3/4 in [7.0 cm]
5 3/16 in [13.2 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
40 3/8 in [102.6 cm]
11 in [27.9 cm]
OPERATING STATUS
15 in [38.1 cm]
4 1/8 in [10.5 cm]
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/2"NAT & LP
29 5/16 in [74.4 cm]
7 13/16 in [19.8 cm]
5 in [12.7 cm]
37 15/16 in [96.4 cm]
26 5/8 in [67.7 cm]
102 7/16 in [260.3 cm]
35 3/16 in [89.42 cm]
30 1/8 in [76.6 cm]
41 11/16 in [105.9 cm]
14 in [35.6 cm]
19 1/16 in [48.48 cm]
12 15/16 in [32.86 cm]
47 7/8 in [121.57 cm]
50 5/16 in [127.72 cm]
Ø12 in [Ø30.5 cm]
7 1/2 in [19.1 cm]
29 5/8 in [75.2 cm]
26 3/8 in [67.0 cm]4 3/16 in
[10.7 cm]
97 3/8 in [247.3 cm]48 11/16 in
[123.7 cm]
2 3/4 in [7.0 cm]
5 3/16 in [13.2 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
40 3/8 in [102.6 cm]
11 in [27.9 cm]
OPERATING STATUS
15 in [38.1 cm]
4 1/8 in [10.5 cm]
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/2"NAT & LP
29 5/16 in [74.4 cm]
7 13/16 in [19.8 cm]
5 in [12.7 cm]
37 15/16 in [96.4 cm]
26 5/8 in [67.7 cm]
102 7/16 in [260.3 cm]
35 3/16 in [89.42 cm]
30 1/8 in [76.6 cm]
41 11/16 in [105.9 cm]
14 in [35.6 cm]
19 1/16 in [48.48 cm]
12 15/16 in [32.86 cm]
47 7/8 in [121.57 cm]
50 5/16 in [127.72 cm]
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
LCD 1970Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 11.0*
Input BTU/hr. 1,970,000 / 577 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 1,615,400 / 473 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 1073 lbs. / 487 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944B 1-1/2" Pilot Valve Honeywell VR8205Q
Firing Valve Honeywell B200T1058 1-1/2" Air Switch Cleveland RSS-495
Safety Valve Honeywell V48A 1-1/2" Blower Motor (2) 1/4 hp - FLA 10.2
Ignition Control UTC 1003-61A Relief Valve - LW 3/4" x 3/4" set @ 125 psi
Operating Control (LB/LW) Jumo Relief Valve - LB 1" x 1-1/4" set @ 50 psi
High Limit (LB/LW) Jumo Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 189 Sq. Ft. / 17.56 Sq. M. Design Data Max. 160 psig & 250°F
Water Volume 5.4 gal / 20.4 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa
107.7 6.8 8.75 25.8 92.3 5.8 6.58 19.4
* Add circulator amps.** For incoming gas pressures lower than 7" WC natural or 11" WC propane, consult factory.
SLCD-1970-7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
4872 18415 3248 12277 2436 9208 1949 7366 1624 6138 1392 5262
The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
LCD 2300Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SLCD-2300-7The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-24-F
51 15/16 in [131.9 cm]
103 7/8 in [263.8 cm]
4 3/16 in [10.7 cm]
29 7/8 in [75.9 cm]
2 3/4 in [7.0 cm]
5 3/16 in [13.2 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø12 in [Ø30.5 cm]
REAR FLUEOUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
OPERATING STATUS
43 5/8 in [110.9 cm]
11 in [27.9 cm]
15 in [38.1 cm]
4 1/8 in [10.5 cm]
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø2"NAT & LP
29 5/16 in [74.4 cm]7 13/16 in
[19.8 cm]5 in
[12.7 cm]
37 15/16 in [96.3 cm]
26 5/8 in [67.7 cm]
108 15/16 in [276.8 cm]
30 in [76.2 cm]35 3/16 in
[89.42 cm]
14 in [35.6 cm]
44 15/16 in [114.1 cm]
19 1/16 in [48.48 cm]
12 15/16 in [32.86 cm]
51 1/16 in [129.70 cm]
50 5/16 in [127.72 cm]
51 15/16 in [131.9 cm]
103 7/8 in [263.8 cm]
4 3/16 in [10.7 cm]
29 7/8 in [75.9 cm]
2 3/4 in [7.0 cm]
5 3/16 in [13.2 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø12 in [Ø30.5 cm]
REAR FLUEOUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
OPERATING STATUS
43 5/8 in [110.9 cm]
11 in [27.9 cm]
15 in [38.1 cm]
4 1/8 in [10.5 cm]
15 7/16 in [39.1 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø2"NAT & LP
29 5/16 in [74.4 cm]7 13/16 in
[19.8 cm]5 in
[12.7 cm]
37 15/16 in [96.3 cm]
26 5/8 in [67.7 cm]
108 15/16 in [276.8 cm]
30 in [76.2 cm]35 3/16 in
[89.42 cm]
14 in [35.6 cm]
44 15/16 in [114.1 cm]
19 1/16 in [48.48 cm]
12 15/16 in [32.86 cm]
51 1/16 in [129.70 cm]
50 5/16 in [127.72 cm]
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
LCD 2300Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 12.5*
Input BTU/hr. 2,300,000 / 674 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 1,886,000 / 553 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 1085 lbs. / 493 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944B 2" Pilot Valve Honeywell VR8205Q
Firing Valve Honeywell B200T1066 2" Air Switch Cleveland RSS-495
Safety Valve Honeywell V48A 2" Blower Motor (2) 1/4 hp (1) 1/5 hp - FLA 13.2
Ignition Control UTC 1003-61A Relief Valve - LW 3/4" x 3/4" set @ 125 psi
Operating Control (LB/LW) Jumo Relief Valve - LB 1" x 1-1/4" set @ 50 psi
High Limit (LB/LW) Jumo Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 202 Sq. Ft. / 18.77 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 5.6 gal / 21.4 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa
125.7† 7.9† 12.45 36.7 107.8 6.8 9.36 27.6
* Add circulator amps.** For incoming gas pressures lower than 7" WC natural or 11" WC propane, consult factory.
SLCD-2300-7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
5695 21526 3797 14351 2847 10763 2278 8611 1898 7175 1627 6150
The LCD Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
† Flow exceeds recommended maximum use a greater temperature rise or consult manufacturer. Cupronickel heat exchanger should be considered.