Page 1: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS

Power Triggering

Etienne CARLIER & Jean-Louis BRETIN

AB/BT/EC

Page 2: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Outline

• Architecture• Power Trigger Unit

– Block diagram– Characteristics

• Power Trigger Module– Circuit– Signals

• Protection• Power Trigger Controller

– State– Signals

• Re-triggering

Etienne CARLIER, LBDS Audit – 28/01/2007

Page 3: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS

Fault-tolerantFail-safe

Trigger Synchronisation & DistributionArchitecture

Re-trigger lines

Branch A

BranchB

BranchA

BranchB

Generator 1

Generator 15

TFO

TFO

Trigger Fan-out

PTU

PTU

PTU

PTU

Power Trigger

Unit

RTB

RTB

RTB

RTB

Re-trigger Box

RTD

TSU

TSUClient Interface

Frev

Trigger Synchronisation

Unit

Etienne CARLIER, LBDS Audit – 28/01/2007

Page 4: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Power Trigger UnitBlock Diagram

DriverMain

Compensation

Controller

Power Supplies

+5V±15V+48V±150V

+3000V

PTM (Power Trigger Module)

DriverMain

Compensation

PTM (Power Trigger Module)

PTC (Power Trigger Controller)

Inputs

Trig 1Trig 2

Re-Trig 1Re-Trig 2Soft Trig

Etienne CARLIER, LBDS Audit – 28/01/2007

PTU (Power Trigger Unit)

Page 5: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Power Trigger UnitCharacteristics

• Two independent « power » outputs– One power output is able to trigger one branch of one generator– 2 power outputs can be operated in parallel

• Single output trigger pulse for principal and compensation circuits– Variable voltage for principal circuit (generator turn-on delay compensation)– Fixed voltage for compensation circuit

• 5 different trigger inputs– 2 redundant normal inputs– 2 redundant re-trigger inputs– 1 soft trigger

• Full monitoring via PROFIBUS-DP– Static mode SCSS– Pulse mode IPOC

Etienne CARLIER, LBDS Audit – 28/01/2007

Page 6: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Power Trigger ModuleCircuit

Etienne CARLIER, LBDS Audit – 28/01/2007

Page 7: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Power Trigger ModuleSignals

• Operating range: 600 V to 3 kV• Maximum output current 275 A• 2.5 µs pulse duration• No turn-on jitter

Etienne CARLIER, LBDS Audit – 28/01/2007

• Operating voltage: -150 V• Mean output current: 75 A• Pulse duration > 400 µs

PRINCIPAL CIRCUIT TRIGGER COMPENSATION CIRCUIT TRIGGER

Page 8: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Triggering CircuitProtection

Trigger HV Transformer

Main Switch

Compensation Switch

PTM

PTM

Etienne CARLIER, LBDS Audit – 28/01/2007

HV Diode to protect redundant PTM in case of short-circuit at the output of the other module

Tri-axial cable for EMC protection

Single triggering transformer for principal and compensation circuit no incoherent kick

Page 9: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS MonitoringState Diagram

Etienne CARLIER, LBDS Audit – 28/01/2007

FAULTY

OK

STATIC MODE

READY

DATAVALID

DATACHECK

TriggerArm

PULSE MODE

Page 10: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS MonitoringSignals

• State• High voltage

– Control– Status

• Low voltage– +15V – +48V – +150V

• Watchdog status• Soft-trigger status

Etienne CARLIER, LBDS Audit – 28/01/2007

• Trigger inputs– Trig IN1 & IN2– Re-Trig IN1 & IN2– Soft Trigger

• Driver circuits– PTMA & PTMB

• Re-trigger box inputs• Output pulse waveform

analysis– Primary voltage– Primary current– Secondary current

STATIC MODE PULSE MODE

Page 11: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Pictures

Power SuppliesPower Trigger Controller

Power Trigger ModulePower Trigger Unit

Etienne CARLIER, LBDS Audit – 28/01/2007

Page 12: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS

Fault-tolerantFail-safe

Trigger Synchronisation & DistributionArchitecture

Re-trigger lines

Branch A

BranchB

BranchA

BranchB

Generator 1

Generator 15

TFO

TFO

Trigger Fan-out

PTU

PTU

PTU

PTU

Power Trigger

Unit

RTB

RTB

RTB

RTB

Re-trigger Box

RTD

TSU

TSUClient Interface

Frev

Trigger Synchronisation

Unit

Etienne CARLIER, LBDS Audit – 28/01/2007

Page 13: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Re-TriggeringSensors

Etienne CARLIER, LBDS Audit – 28/01/2007

Re-trigger Line A

Re-trigger Line B

I

I

I

I

V

V

I : CurrentV: Voltage

Page 14: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Re-triggering BoxPrinciple

Etienne CARLIER, LBDS Audit – 28/01/2007

To Power Trigger Unit

From Sensors

Page 15: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Re-TriggeringCharacteristics

• Fully passive fault tolerant system– Complete post-mortem analysis after each dump action

• All the power needed to re-trigger the complete extraction kicker system is available directly from the sensors– Current pick-ups– High voltage dividers

• Re-trigger delay is due to – Detection time– Propagation time over the 14 remaining generators– Power trigger turn on delay– Main switch turn on delay

Etienne CARLIER, LBDS Audit – 28/01/2007

Page 16: LBDS Power Triggering Etienne CARLIER & Jean-Louis BRETIN AB/BT/EC

LBDS Re-triggeringHardware

Etienne CARLIER, LBDS Audit – 28/01/2007

Re-Trigger Box