landmark san antonio€¦ · above finished floor sidewall supply register ceiling supply register...
TRANSCRIPT
VENT THRU ROOF
TRANSFER GRILLE
CEILING DIFFUSER
ABOVE FINISHED FLOOR
SIDEWALL SUPPLY REGISTER
CEILING SUPPLY REGISTER
RETURN AIR FILTER GRILLE
RETURN AIR REGISTER
FAN COIL
RETURN AIR
ROOFTOP A/C UNIT
CONDENSING UNIT
EXHAUST REGISTER
EXHAUST FAN
AIR HANDLING UNIT
SSR
CSR
F/C
RTU
AHU
CU
EF
ER
R/A
RAR
RAFG
FD
CD
VTR
TG
DG
EXH
DIA
OA
MU
AFF
EXHAUST
DIAMETER
DOOR GRILLE
OUTSIDE AIR
FIRE DAMPER
MAKE UP
CEILING RADIATION DAMPERCRD
HVAC COMPLIANCE NOTES:
ABBREVIATIONS
SYMBOL DESCRIPTION
RECTANGULAR SUPPLY DUCT
RECTANGULAR RETURN AIR DUCT
FIRE DAMPER W/ ACCESS PANEL
90° ELL DOWN - FLEX
90° ELL DOWN - RIGID
90° ELL UP - FLEX
90° ELL UP - RIGID
THREE WAY DUCT TRANSITION
FOUR WAY DUCT TRANSITION
BALANCING DAMPER
3-WAY REGISTER - CEILING
4-WAY REGISTER - CEILING
2-WAY REGISTER - CEILING
1-WAY REGISTER - CEILING
LINEAR DIFFUSERS
SIDE WALL REGISTER
AIR HANDLER - HORIZONTAL
AIR HANDLER - VERTICAL
GAS FURNACE
AIR HANDLER - ELECTRIC OR HEAT PUMP
EXHAUST FAN - WALL MOUNT
EXHAUST FAN - CEILING MOUNT
WALL CAP
CONDENSING UNIT OUTSIDE AIR INTAKE - CEILINGO.A.
FLEX DUCT
SPIRAL DUCT
THERMOSTAT
RAFG
FIRE/ SMOKE DAMPER
DUCT FREE EXHAUST FAN - CEILING MOUNT
DUCT SMOKE DETECTOR
BASEBOARD HEATER
COMBUSTION AIR LOUVERS IN WALL OR DOOR
CASED AIR HANDLER - HORIZONTAL
OUTSIDE AIR INTAKE - WALLO.A.
MECHANICAL SYMBOL SCHEDULE
ALL SYMBOLS DO NOT NECESSARILY APPEAR ON ALL DRAWINGS.SYMBOLS ARE NOT SCALED.
CONTRACTOR SHALL PROVIDE WATERTIGHT AND WATER PROOFINSTALLATION OF ALL DRYER AND EXHAUST VENT CAPS.
COORDINATE FLASHING AND WATERPROOFING WITH GENERALCONTRACTOR.
MECHANICAL CONTRACTOR SHALL:
VERIFY THAT ALL WORK IS COMPLETED AND IS IN COMPLIANCEWITH THE DESIGN INTENT. ALL WORK SHALL BE IN COMPLIANCEWITH ALL LOCAL AND NATIONAL CODES AND OR ORDINANCES.
FURNISH AND INSTALL ALL HVAC EQUIPMENT, DUCT WORK ANDREFRIGERANT PIPING AS WELL AS ALL OTHER ITEMS NECESSARY
TO COMPLETE THE PROJECT PER MANUFACTURER'SRECOMMENDATIONS.
PROVIDE SLEEVES AND OTHER NECESSARY ITEMS TO WEATHERPROOF PENETRATIONS OF BUILDING BY REFRIGERANT LINES ANDEXHAUST DUCTS.
USE ONLY APPROVED TAPES AND HANGERS FOR DUCT.
INSTALL R6 DUCT IN DROP CEILINGS OR FLOOR TRUSSES AND R8DUCT IN ATTICS OR OTHER UNCONDITIONED SPACES OTHER THANFLOOR TRUSS.
PROVIDE EACH HVAC SYSTEM WITH A PROPERLY SIZED NEWFILTER.
VERIFY TYPE OF FILTER REQUIRED BY 2009 IECC PRIOR TOINSTALLATION.
PROVIDE FIRE DAMPERS AND CEILING RADIATION DAMPERS AT
PENETRATIONS OF ANY RATED ASSEMBLY OR WHERE REQUIRED BYCODE OR LOCAL AUTHORITIES.
COORDINATE PRIOR TO INSTALLATION OF ANY EQUIPMENT OR
DUCTWORK WITH ALL OTHER TRADES AND GENERALCONTRACTOR.
VERIFY THAT ALL DRYER AN EXHAUST VENT HOODS ARE
INSTALLED PER MANUFACTURES REQUIREMENTS AND AREWEATHER TIGHT.
REFRIGERANT LINES PENETRATING THROUGH ANY PORTION OFTHE BUILDING SHALL BE INSTALLED TO PREVENT ANY ACCESS OF
WATER, INSECTS OR INCLEMENT WEATHER THAT COULD BREACHTHE BUILDING ENVELOPE. COORDINATE FLASHING AND WATERPROOFING WITH GENERAL CONTRACTOR.
PVC SHALL NOT BE USED IN RETURN AIR PLENUMS UNLESS
APPROVED BY LOCAL AUTHORITIES.
CONTRACTOR SHALL LOCATE ALL EXHAUST HOODS A MIN. OF 36"FROM ANY OPERABLE WINDOW, DOOR OR OPENING INTO THE
BUILDING.
CONTRACTOR SHALL VERIFY MFG. REQUIREMENTS FORREFRIGERANT LINES AND SHALL NOT EXCEED MFG.RECOMMENDED MAXIMUM LENGTHS BOTH HORIZONTAL AND
VERTICAL.
CONTRACTOR SHALL NOT REQUEST ADDITIONAL SERVICES FORFAILURE TO EXAMINE AND BE KNOWLEDGEABLE OF ALLCONSTRUCTION DOCUMENT REQUIREMENTS, INCLUDING BUT NOT
LIMITED TO THE ELECTRICAL, MECHANICAL, PLUMBING, CIVIL,LANDSCAPE, STRUCTURAL AND ARCHITECTURAL.
NO COMBUSTIBLE MATERIALS SHALL BE LOCATED IN RETURN ORSUPPLY AIR PLENUMS.
MECHANICAL CONTRACTOR SHALL INSTALL LOUVERS THROUGHWALL, PROVIDING A MINIMUM OF 100 SQ. INCHES OF MAKEUP AIRFOR ALL CLOTHES DRYER CLOSETS.
CONDENSING UNITS SHALL BE SECURED PER SMACNA STANDARDS.
CONTRACTOR SHALL VERIFY A MINIMUM OF 13.0 SEER ON ALL HVACUNITS PRIOR TO INSTALLATION.
CONTRACTOR SHALL VERIFY COMPATIBILITY OF AIR HANDLERSAND CONDENSING UNITS PRIOR TO PURCHASE AND OR
INSTALLATION.
CONTRACTOR SHALL USE THERMOSTATIC EXPANTION VALVESWHERE REQUIRED BY MANUFACTURER.
SQUARE DUCT
ALL CONDENSING UNITS SHALL BE INSTALLED ON 4" CONCRETEPAD. DISTANCES FROM STRUCTURES SHALL BE MAINTAINED TO
MANUFACTURERS REQUIREMENTS.
WATER HEATER VENT TERMINATION POINT SHALL BE 10' FROM
EDGE OF ROOF.
ALL REFRIGERANT CIRCUITS SERVICE PORTS LOCATED ON THE
EXTERIOR OF THE BUILDING SHALL BE PROVIDED WITH LOCKINGACCESS PORT CAPS.
DESIGN OF MECHANICAL SYSTEMS ARE BASED ON INFORMATIONPROVIDED BY OTHERS WITH NO GUARANTEE AS TO ACCURACY.
PRIMARY DRAIN LINES LOCATED IN ANY UNCONDITIONED SPACE,
EXCEPT FOR CRAWL SPACES, SHALL BE INSULATED WITH FOAMPLASTIC RUBBER BASED INSULATION OR OTHER APPROVEDMATERIAL WITH A MINIMUM THICKNESS OF 3/8 INCH.
15
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M1
N/A
15 ADA COMMENTS 07-21-2014
2
8
18
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M2
N/A
2
01-22-14
DELETED GARAGE
FAN SCHEDULE
8 05-16-2014ID COMMENTS
18 OWNERS CHANGES 9-08-2014
A
25" x 12"RAFG
B
D
GI
T
C
F
H
K
12" x 6" CSR180 CFM3-WAYW/CRD
8" Ø
9" Ø
3" Ø
12" x 6" SSR
160 CFM
7" Ø
8" x 6" CSR80 CFM3-WAY
6" Ø12" x 6" SSR180 CFM
6
HORIZONTAL FAN COIL UNIT MOUNTED IN
FURR DOWN AS HIGH AS POSSIBLE.
FAN COIL CEILING ACCESS PANEL. PANEL
SHALL BE GASKETED AND AIR TIGHT.
SHEETROCK UP TO FURR DOWN ONLY
EXHAUST FAN IN WALL, EXTEND DUCT UP TOJOIST SPACE. TOP FLOOR SHALL HAVE THE
OPTION TO ROUTE DUCT DOWN TO JOISTSPACE BELOW.
WALL CAPS, EACH EXHAUST WALL CAP SHALLMAINTAIN A MINIMUM DISTANCE OF 36" FROM
ANY OPERABLE OPENING TO THE BUILDINGAND SHALL BE SEALED WEATHER TIGHT.
WATER HEATER BY PLUMBING CONTRACTOR.
DRYER VENT UP IN WALL.
DRYER VENT IN TRUSS/JOIST SPACE. EACHDRYER VENT SHALL BE 26 GAUGE RIDGED
SMOOTH METAL WITH ALL JOINTS CONNECTEDIN THE DIRECTION OF AIR FLOW.
MAKEUP AIR LOUVER, REFER TOARCHITECTURAL UNIT PLANS FOR
CALCULATIONS AND SIZING.
FIRE DAMPER WITH ACCESS PANEL. ALL FIRE
DAMPERS SHALL BE INSTALLED INACCORDANCE TO ALL SMACNA AND LOCALREQUIREMENTS.
B
A
C
D
E
F
G
H
I
J
MECHANICAL NOTES BY SYMBOL:
EXHAUST VENT IN TRUSS/JOIST SPACE.K
FURR DOWN LEGEND
MECHANICAL CONTRACTOR SHALL VERIFYTHAT ALL DRYER AND EXHAUST VENT HOODS
ARE INSTALLED PER MANUFACTURESREQUIREMENTS AND ARE WEATHER TIGHT.
REFRIGERANT LINE PENETRATION THROUGH ANYPORTION OF THE BUILDING SHALL BE INSTALLEDTO PREVENT ANY ACCESS OF WATER, INSECTS OR
INCLEMENT WEATHER REACHING THE INSIDE OFTHE BUILDING ENVELOPE.
RETURN AIR FURR DOWN, MECHANICAL
CONTRACTOR SHALL VERIFY ALL RETURN AIRFURRING IS AIR TIGHT AND SEPARATE FROMANY NON RETURN FURRING. CONTRACTOR
SHALL ALSO ENSURE THAT RETURN AIR PATH
FROM RETURN AIR GRILL TO AIR HANDLER ISCLEAR OF OBSTRUCTIONS THAT WOULD CAUSE
RESTRICTION TO RETURN AIR.
NON RETURN AIR FURR DOWN - SEPERATEFROM FURRING USED FOR RETURN AIR.
A B
C
H
K
3" Ø
12" x 6" SSR160 CFM
7" Ø
8" x 6" CSR
80 CFM3-WAY
6" Ø
A B
D
C
H
K
3" Ø
12" x 6" SSR
160 CFM
7" Ø
8" x 6" CSR80 CFM
3-WAY
6" Ø
D
I
25" x 12"
RAFG
G
T
A B F
K
8" x 6"
CSR 70CFM3-WAY
6" Ø
12" x 6" SSR180 CFM
8" Ø
12" x 6" CSR180 CFM3-WAY
W/CRD
12" x 6" CSR170 CFM
3-WAYW/CRD
8" Ø
8" Ø
9" Ø
D
I
G
25" x 12"RAFG
T
A BC
F
H
K
8"Ø
12" x 6" SSR170 CFM
8"Ø
8" x 6" CSR
80 CFM3-WAY - 5"Ø 4"Ø
6"Ø
12" x 6" SSR150 CFM
7"Ø
12" x 6" CSR 170 CFM3-WAY
A B
H
K
8"Ø
4"Ø
6"Ø
12" x 6" SSR150 CFM
7"Ø
D
I
G
25" x 12"
RAFG
T
A BC
F
H
K
8"Ø
12" x 6" SSR170 CFM
8"Ø
8" x 6" CSR 80 CFM
3-WAY - 5"Ø4"Ø
6"Ø
12" x 6" SSR
150 CFM
7"Ø
12" x 6" CSR
170 CFM3-WAY
T
I
D
A
B
CF
25" x 12"RAFG
G
H
K
12" x 6" CSR 190 CFM
3-WAYW/CRD
8"Ø
12" x 6" CSR
150 CFM3-WAYW/CRD
7"Ø
9"Ø
3"Ø
4"Ø
12" x 6" SSR
150 CFM
7"Ø
10" x 6" CSR
110 CFM3-WAY
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M3
1/4" = 1' - 0"
1/4" = 1'-0"
UNIT TYPE A1
1/4" = 1'-0"
UNIT TYPE A1-A
1/4" = 1'-0"
UNIT TYPE A1-B
1/4" = 1'-0"
UNIT TYPE A2
1/4" = 1'-0"
UNIT TYPE A3
1/4" = 1'-0"
UNIT TYPE A3-A
1/4" = 1'-0"
UNIT TYPE A3-B
1/4" = 1'-0"
UNIT TYPE A3-HC
5 REVISEDBACKGROUND,
OWNERS CHANGES
5 OWNERS CHANGES 4-21-2014
6 CITY COMMENTS 05-02-2014
25" x 12"RAFG
D
G
I
T
A
B
C
CF
H
K
14" x 6" CSR 220 CFM
3-WAYW/CRD
9"Ø
10" x 6" SSR110 CFM
6"Ø
8" x 4" CSR70 CFM
3-WAY 4"Ø
14" x 6" SSR200 CFM
8"Ø
3"Ø
HORIZONTAL FAN COIL UNIT MOUNTED INFURR DOWN AS HIGH AS POSSIBLE.
FAN COIL CEILING ACCESS PANEL. PANELSHALL BE GASKETED AND AIR TIGHT.
SHEETROCK UP TO FURR DOWN ONLY
EXHAUST FAN IN WALL, EXTEND DUCT UP TOJOIST SPACE. TOP FLOOR SHALL HAVE THEOPTION TO ROUTE DUCT DOWN TO JOIST
SPACE BELOW.
WALL CAPS, EACH EXHAUST WALL CAP SHALLMAINTAIN A MINIMUM DISTANCE OF 36" FROMANY OPERABLE OPENING TO THE BUILDINGAND SHALL BE SEALED WEATHER TIGHT.
WATER HEATER BY PLUMBING CONTRACTOR.
DRYER VENT UP IN WALL.
DRYER VENT IN TRUSS/JOIST SPACE. EACH
DRYER VENT SHALL BE 26 GAUGE RIDGEDSMOOTH METAL WITH ALL JOINTS CONNECTEDIN THE DIRECTION OF AIR FLOW.
MAKEUP AIR LOUVER, REFER TOARCHITECTURAL UNIT PLANS FORCALCULATIONS AND SIZING.
FIRE DAMPER WITH ACCESS PANEL. ALL FIREDAMPERS SHALL BE INSTALLED INACCORDANCE TO ALL SMACNA AND LOCAL
REQUIREMENTS.
B
A
C
D
E
F
G
H
I
J
MECHANICAL NOTES BY SYMBOL:
EXHAUST VENT IN TRUSS/JOIST SPACE.K
FURR DOWN LEGEND
MECHANICAL CONTRACTOR SHALL VERIFYTHAT ALL DRYER AND EXHAUST VENT HOODS
ARE INSTALLED PER MANUFACTURESREQUIREMENTS AND ARE WEATHER TIGHT.
REFRIGERANT LINE PENETRATION THROUGH ANY
PORTION OF THE BUILDING SHALL BE INSTALLEDTO PREVENT ANY ACCESS OF WATER, INSECTS ORINCLEMENT WEATHER REACHING THE INSIDE OF
THE BUILDING ENVELOPE.
RETURN AIR FURR DOWN, MECHANICALCONTRACTOR SHALL VERIFY ALL RETURN AIRFURRING IS AIR TIGHT AND SEPARATE FROM
ANY NON RETURN FURRING. CONTRACTORSHALL ALSO ENSURE THAT RETURN AIR PATHFROM RETURN AIR GRILL TO AIR HANDLER IS
CLEAR OF OBSTRUCTIONS THAT WOULD CAUSERESTRICTION TO RETURN AIR.
NON RETURN AIR FURR DOWN - SEPERATEFROM FURRING USED FOR RETURN AIR.
H
K
14" x 6" CSR 220 CFM
3-WAYW/CRD
36" x 12"
RAFGT
A
B
C
F
I
K
3"Ø
4"Ø
14" x 6" SSR
220 CFM8"Ø
10" x 6" SSR120 CFM
6"Ø8" x 6" CSR
100 CFM3-WAY
6"Ø
7"Ø
14" x 6" SSR160 CFM
4
K
3"Ø
4"Ø
K
14" x 6" SSR220 CFM
8"Ø
7"Ø
14" x 6" SSR160 CFM
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M4
1/4" = 1' - 0"
1/4" = 1'-0"
UNIT TYPE A41/4" = 1'-0"
UNIT TYPE A4-A
1/4" = 1'-0"
UNIT TYPE A5, A5-A, A5-B, A5-C
1/4" = 1'-0"
UNIT TYPE A5-D
1/4" = 1'-0"
UNIT TYPE A5-E
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND, A5,
A5A, A5B
5 REVISEDBACKGROUND,
OWNERS CHANGES
5 OWNERS CHANGES 4-21-2014
E
D
G
I
36" x 12"
RAFG
T
A
B
C
F
H
K
12" x 6" CSR
200 CFM3-WAYW/CRD
8"Ø
8" x 8" CSR 150 CFM
4-WAYW/CRD
7"Ø
9"Ø
10" x 6" SSR
150 CFM
8" x 6" CSR 70 CFM
3-WAY
6"Ø
8" x 4" SSR
30 CFM
4"Ø
4"Ø
3"Ø3"Ø
4
HORIZONTAL FAN COIL UNIT MOUNTED INFURR DOWN AS HIGH AS POSSIBLE.
FAN COIL CEILING ACCESS PANEL. PANELSHALL BE GASKETED AND AIR TIGHT.
SHEETROCK UP TO FURR DOWN ONLY
EXHAUST FAN IN WALL, EXTEND DUCT UP TOJOIST SPACE. TOP FLOOR SHALL HAVE THE
OPTION TO ROUTE DUCT DOWN TO JOISTSPACE BELOW.
WALL CAPS, EACH EXHAUST WALL CAP SHALLMAINTAIN A MINIMUM DISTANCE OF 36" FROMANY OPERABLE OPENING TO THE BUILDING
AND SHALL BE SEALED WEATHER TIGHT.
WATER HEATER BY PLUMBING CONTRACTOR.
DRYER VENT UP IN WALL.
DRYER VENT IN TRUSS/JOIST SPACE. EACHDRYER VENT SHALL BE 26 GAUGE RIDGEDSMOOTH METAL WITH ALL JOINTS CONNECTED
IN THE DIRECTION OF AIR FLOW.
MAKEUP AIR LOUVER, REFER TOARCHITECTURAL UNIT PLANS FORCALCULATIONS AND SIZING.
FIRE DAMPER WITH ACCESS PANEL. ALL FIRE
DAMPERS SHALL BE INSTALLED INACCORDANCE TO ALL SMACNA AND LOCALREQUIREMENTS.
B
A
C
D
E
F
G
H
I
J
MECHANICAL NOTES BY SYMBOL:
EXHAUST VENT IN TRUSS/JOIST SPACE.K
FURR DOWN LEGEND
MECHANICAL CONTRACTOR SHALL VERIFYTHAT ALL DRYER AND EXHAUST VENT HOODS
ARE INSTALLED PER MANUFACTURESREQUIREMENTS AND ARE WEATHER TIGHT.
REFRIGERANT LINE PENETRATION THROUGH ANYPORTION OF THE BUILDING SHALL BE INSTALLEDTO PREVENT ANY ACCESS OF WATER, INSECTS OR
INCLEMENT WEATHER REACHING THE INSIDE OFTHE BUILDING ENVELOPE.
RETURN AIR FURR DOWN, MECHANICAL
CONTRACTOR SHALL VERIFY ALL RETURN AIRFURRING IS AIR TIGHT AND SEPARATE FROMANY NON RETURN FURRING. CONTRACTOR
SHALL ALSO ENSURE THAT RETURN AIR PATH
FROM RETURN AIR GRILL TO AIR HANDLER ISCLEAR OF OBSTRUCTIONS THAT WOULD CAUSE
RESTRICTION TO RETURN AIR.
NON RETURN AIR FURR DOWN - SEPERATE
FROM FURRING USED FOR RETURN AIR.
E
D
H
K
10"
8" x 6" CSR 70 CFM
3-WAY
4"Ø
3"Ø3"Ø
12" x 6" CSR200 CFM
3-WAYW/CRD
G
36" x 12RAFG
T
A
B
C
F
9"Ø
10" x 6" SSR
150 CFM
CSR
FMY
6"Ø
8" x 4" SSR30 CFM
4"Ø
"Ø
4
36" x 12"
RAFGI
DT
A
B
C
F
K
10" x 6" CSR 160 CFM3-WAYW/CRD
7"Ø
10" x 6" CSR 100 CFM
3-WAYW/CRD
6"Ø10" x 6" SSR130 CFM
7"Ø
8" x 4" CSR 70 CFM
3-WAY
5"Ø
8" x 4" CSR 50 CFM3-WAY
W/CRD
5"Ø
6"Ø
12" x 6" SSR90 CFM
6"Ø
3"Ø
4"Ø
36" x 12"RAFG
T
F
3"Ø
4"Ø 12" x 6" SSR160 CFM
7"Ø
12" x 6" SSR
150 CFM
7"Ø
12" x 6" SSR
160 CFM
7"Ø
10" x 6" CSR 90 CFM3-WAY
6"Ø
8" x 4" CSR
40 CFM3-WAY
5"Ø
7"Ø
3"Ø
4"Ø
10" x 6" CSR 90 CFM3-WAY
6"Ø
5"Ø
7"Ø
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M5
1/4" = 1' - 0"
1/4" = 1'-0"
UNIT TYPE A6
1/4" = 1'-0"
UNIT TYPE A6-A
1/4" = 1'-0"
UNIT TYPE A6-B
1/4" = 1'-0"
UNIT TYPE A6-C
1/4" = 1'-0"
UNIT TYPE A7
1/4" = 1'-0"
UNIT TYPE A8
1/4" = 1'-0"
UNIT TYPE A8-A
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND, A6,
A6A, A6B, A6C
5 REVISEDBACKGROUND,
OWNERS CHANGES
5 OWNERS CHANGES 4-21-2014
36" x 12"
RAFG
T
A
B
D
F
H
I
K
12" x 6" CSR 190 CFM3-WAYW/CRD
12" x 6" CSR 220 CFM3-WAYW/CRD
8"Ø
8"Ø
10"Ø
10" x 6" CSR 110 CFM
3-WAYW/CRD
7"Ø
12" x 6" CSR 200 CFM3-WAY
W/CRD
8"Ø
9"Ø
8" x 6" CSR 80 CFM3-WAY
5"Ø
13
HORIZONTAL FAN COIL UNIT MOUNTED INFURR DOWN AS HIGH AS POSSIBLE.
FAN COIL CEILING ACCESS PANEL. PANELSHALL BE GASKETED AND AIR TIGHT.
SHEETROCK UP TO FURR DOWN ONLY
EXHAUST FAN IN WALL, EXTEND DUCT UP TOJOIST SPACE. TOP FLOOR SHALL HAVE THE
OPTION TO ROUTE DUCT DOWN TO JOISTSPACE BELOW.
WALL CAPS, EACH EXHAUST WALL CAP SHALLMAINTAIN A MINIMUM DISTANCE OF 36" FROMANY OPERABLE OPENING TO THE BUILDING
AND SHALL BE SEALED WEATHER TIGHT.
WATER HEATER BY PLUMBING CONTRACTOR.
DRYER VENT UP IN WALL.
DRYER VENT IN TRUSS/JOIST SPACE. EACHDRYER VENT SHALL BE 26 GAUGE RIDGEDSMOOTH METAL WITH ALL JOINTS CONNECTED
IN THE DIRECTION OF AIR FLOW.
MAKEUP AIR LOUVER, REFER TOARCHITECTURAL UNIT PLANS FORCALCULATIONS AND SIZING.
FIRE DAMPER WITH ACCESS PANEL. ALL FIREDAMPERS SHALL BE INSTALLED IN
ACCORDANCE TO ALL SMACNA AND LOCALREQUIREMENTS.
B
A
C
D
E
F
G
H
I
J
MECHANICAL NOTES BY SYMBOL:
EXHAUST VENT IN TRUSS/JOIST SPACE.K
FURR DOWN LEGEND
MECHANICAL CONTRACTOR SHALL VERIFYTHAT ALL DRYER AND EXHAUST VENT HOODS
ARE INSTALLED PER MANUFACTURESREQUIREMENTS AND ARE WEATHER TIGHT.
REFRIGERANT LINE PENETRATION THROUGH ANYPORTION OF THE BUILDING SHALL BE INSTALLEDTO PREVENT ANY ACCESS OF WATER, INSECTS OR
INCLEMENT WEATHER REACHING THE INSIDE OFTHE BUILDING ENVELOPE.
RETURN AIR FURR DOWN, MECHANICAL
CONTRACTOR SHALL VERIFY ALL RETURN AIRFURRING IS AIR TIGHT AND SEPARATE FROMANY NON RETURN FURRING. CONTRACTOR
SHALL ALSO ENSURE THAT RETURN AIR PATH
FROM RETURN AIR GRILL TO AIR HANDLER ISCLEAR OF OBSTRUCTIONS THAT WOULD CAUSE
RESTRICTION TO RETURN AIR.
NON RETURN AIR FURR DOWN - SEPERATE
FROM FURRING USED FOR RETURN AIR.
H
12" x 6" CSR 190 CFM
3-WAYW/CRD
12" x 6" CSR
220 CFM3-WAYW/CRD
8"Ø
8"Ø
10" x 6" CSR 110 CFM
T
G
D
I
24" x 18"RAFG
A
B
C
F
H
K
12" x 6" CSR 160 CFM3-WAY
W/CRD
12" x 6" CSR 170 CFM3-WAY
W/CRD
7"Ø
8"Ø
9"Ø
12" x 6" CSR 180 CFM
3-WAYW/CRD
8"Ø
10" x 6" CSR
90 CFM3-WAY
6"Ø
10" x 6" SSR
140 CFM
7"Ø8" x 6" SSR60 CFM
5"Ø
3"Ø
4"Ø
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M6
1/4" = 1' - 0"
1/4" = 1'-0"
UNIT TYPE A9
1/4" = 1'-0"
UNIT TYPE A9-A
1/4" = 1'-0"
UNIT TYPE A105 REVISED
BACKGROUND,OWNERS CHANGES
5 OWNERS CHANGES 4-21-2014
13 OWNER CHANGES06-30-2014
GD
D
E
EE
A B
C
F
H
I
J
K
K
J
12" x 6" SSR210 CFM
8"Ø
10" x 6" SSR
140 CFM 7"Ø
10" x 6" SSR140 CFM
7"Ø
8" x 6" CSR 80 CFM3-WAY
6"Ø
8" x 4" CSR 40 CFM3-WAY
5"Ø
10" x 6" SSR
130 CFM
7"Ø
8" x 6" CSR 60 CFM3-WAY
5"Ø
3"Ø
3"Ø
4"Ø
9"Ø
4
30" x 12"RAFG
T
12" x 12" RAFG
HORIZONTAL FAN COIL UNIT MOUNTED INFURR DOWN AS HIGH AS POSSIBLE.
FAN COIL CEILING ACCESS PANEL. PANELSHALL BE GASKETED AND AIR TIGHT.
SHEETROCK UP TO FURR DOWN ONLY
EXHAUST FAN IN WALL, EXTEND DUCT UP TOJOIST SPACE. TOP FLOOR SHALL HAVE THEOPTION TO ROUTE DUCT DOWN TO JOISTSPACE BELOW.
WALL CAPS, EACH EXHAUST WALL CAP SHALLMAINTAIN A MINIMUM DISTANCE OF 36" FROMANY OPERABLE OPENING TO THE BUILDINGAND SHALL BE SEALED WEATHER TIGHT.
WATER HEATER BY PLUMBING CONTRACTOR.
DRYER VENT UP IN WALL.
DRYER VENT IN TRUSS/JOIST SPACE. EACHDRYER VENT SHALL BE 26 GAUGE RIDGEDSMOOTH METAL WITH ALL JOINTS CONNECTEDIN THE DIRECTION OF AIR FLOW.
MAKEUP AIR LOUVER, REFER TOARCHITECTURAL UNIT PLANS FORCALCULATIONS AND SIZING.
FIRE DAMPER WITH ACCESS PANEL. ALL FIREDAMPERS SHALL BE INSTALLED IN
ACCORDANCE TO ALL SMACNA AND LOCALREQUIREMENTS.
B
A
C
D
E
F
G
H
I
J
MECHANICAL NOTES BY SYMBOL:
EXHAUST VENT IN TRUSS/JOIST SPACE.K
FURR DOWN LEGEND
MECHANICAL CONTRACTOR SHALL VERIFYTHAT ALL DRYER AND EXHAUST VENT HOODS
ARE INSTALLED PER MANUFACTURESREQUIREMENTS AND ARE WEATHER TIGHT.
REFRIGERANT LINE PENETRATION THROUGH ANYPORTION OF THE BUILDING SHALL BE INSTALLEDTO PREVENT ANY ACCESS OF WATER, INSECTS OR
INCLEMENT WEATHER REACHING THE INSIDE OFTHE BUILDING ENVELOPE.
RETURN AIR FURR DOWN, MECHANICALCONTRACTOR SHALL VERIFY ALL RETURN AIR
FURRING IS AIR TIGHT AND SEPARATE FROMANY NON RETURN FURRING. CONTRACTOR
SHALL ALSO ENSURE THAT RETURN AIR PATH
FROM RETURN AIR GRILL TO AIR HANDLER ISCLEAR OF OBSTRUCTIONS THAT WOULD CAUSE
RESTRICTION TO RETURN AIR.
NON RETURN AIR FURR DOWN - SEPERATE
FROM FURRING USED FOR RETURN AIR.
D
E
J
K
7"Ø
10" x 6" SSR130 CFM
7"Ø
R
5"Ø
3"Ø
4
30" x 12"RAFG
GD
D
E
EE
T
A B
C
F
H
I
J
J
K
K
12" x 6" SSR210 CFM
8"Ø
10" x 6" SSR140 CFM 7"Ø
10" x 6" SSR140 CFM
7"Ø
8" x 6" CSR 80 CFM3-WAY
6"Ø
8" x 4" CSR 40 CFM3-WAY
5"Ø
10" x 6" SSR130 CFM
7"Ø
8" x 6" CSR 60 CFM3-WAY
5"Ø
3"Ø
3"Ø
4"Ø
9"Ø
4
12" x 12"
RAFG
G36" x 12"RAFG
D
D
E
E
AB
C
F
H
I
JJ
K
K
T
14" x 6" CSR240 CFM3-WAYW/CRD
9"Ø
10" x 6" CSR
130 CFM3-WAYW/CRD
7"Ø
10" x 6" SSR140 CFM7"Ø
8" x 6" CSR 60 CFM3-WAY
5"Ø
3"Ø
3"Ø
4"Ø
8" x 4" CSR
40 CFM3-WAY
5"Ø
10" x 6" CSR
130 CFM3-WAYW/CRD
7"Ø
8" x 6" CSR60 CFM3-WAYW/CRD
5"Ø
7"Ø
10"Ø
7"Ø
10"Ø
4
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M7
1/4" = 1' - 0"
1/4" = 1'-0"
UNIT TYPE B1
1/4" = 1'-0"
UNIT TYPE B1-A
1/4" = 1'-0"
UNIT TYPE B1-HC
1/4" = 1'-0"
UNIT TYPE B2
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND, B1,
B1A, B1HC, B2
5 REVISEDBACKGROUND,
OWNERS CHANGES
5 OWNERS CHANGES 4-21-2014
25" x 20"RAFG
E
H
K
K
T
A
B
C
D
D
F
I
J
12" x 6" CSR
190 CFM3-WAYW/CRD
8" x 6" SSR70 CFM
5"Ø
8"Ø
8" x 6" CSR 80 CFM
3-WAYW/CRD
8"Ø
10"Ø14" x 6" SSR210 CFM
10" x 6" CSR 100 CFM
3-WAY
6"Ø
8"Ø
10" x 6" SSR
100 CFM6"Ø
3"Ø
3"Ø
4"Ø
12" x 6" SSR170 CFM
10" x 6" CSR
80 CFM3-WAY
6"Ø
8"Ø
9"Ø
4
4
HORIZONTAL FAN COIL UNIT MOUNTED INFURR DOWN AS HIGH AS POSSIBLE.
FAN COIL CEILING ACCESS PANEL. PANELSHALL BE GASKETED AND AIR TIGHT.
SHEETROCK UP TO FURR DOWN ONLY
EXHAUST FAN IN WALL, EXTEND DUCT UP TOJOIST SPACE. TOP FLOOR SHALL HAVE THEOPTION TO ROUTE DUCT DOWN TO JOIST
SPACE BELOW.
WALL CAPS, EACH EXHAUST WALL CAP SHALLMAINTAIN A MINIMUM DISTANCE OF 36" FROMANY OPERABLE OPENING TO THE BUILDINGAND SHALL BE SEALED WEATHER TIGHT.
WATER HEATER BY PLUMBING CONTRACTOR.
DRYER VENT UP IN WALL.
DRYER VENT IN TRUSS/JOIST SPACE. EACHDRYER VENT SHALL BE 26 GAUGE RIDGEDSMOOTH METAL WITH ALL JOINTS CONNECTEDIN THE DIRECTION OF AIR FLOW.
MAKEUP AIR LOUVER, REFER TOARCHITECTURAL UNIT PLANS FORCALCULATIONS AND SIZING.
FIRE DAMPER WITH ACCESS PANEL. ALL FIREDAMPERS SHALL BE INSTALLED IN
ACCORDANCE TO ALL SMACNA AND LOCALREQUIREMENTS.
B
A
C
D
E
F
G
H
I
J
MECHANICAL NOTES BY SYMBOL:
EXHAUST VENT IN TRUSS/JOIST SPACE.K
FURR DOWN LEGEND
MECHANICAL CONTRACTOR SHALL VERIFY
THAT ALL DRYER AND EXHAUST VENT HOODSARE INSTALLED PER MANUFACTURES
REQUIREMENTS AND ARE WEATHER TIGHT.
REFRIGERANT LINE PENETRATION THROUGH ANYPORTION OF THE BUILDING SHALL BE INSTALLEDTO PREVENT ANY ACCESS OF WATER, INSECTS OR
INCLEMENT WEATHER REACHING THE INSIDE OFTHE BUILDING ENVELOPE.
RETURN AIR FURR DOWN, MECHANICALCONTRACTOR SHALL VERIFY ALL RETURN AIR
FURRING IS AIR TIGHT AND SEPARATE FROMANY NON RETURN FURRING. CONTRACTOR
SHALL ALSO ENSURE THAT RETURN AIR PATHFROM RETURN AIR GRILL TO AIR HANDLER IS
CLEAR OF OBSTRUCTIONS THAT WOULD CAUSERESTRICTION TO RETURN AIR.
NON RETURN AIR FURR DOWN - SEPERATE
FROM FURRING USED FOR RETURN AIR.
12" x 6" CSR
190 CFM3-WAYW/CRD
8"Ø
8" x 6" CSR 80 CFM
G36" x 12"RAFG
E
EE
AB
C
D
D
F
H
I
J
K
K
T
12" x 8"RAFG
12" x 6" CSR
170 CFM3-WAYW/CRD
9"Ø
10" x 6" CSR
130 CFM3-WAYW/CRD
7"Ø
12" x 6" CSR 180 CFM3-WAY
W/CRD8"Ø
10"Ø
8" x 6" CSR 90 CFM3-WAY
W/CRD
8" x 4" CSR 50 CFM
3-WAYW/CRD
5"Ø
6"Ø
12" x 6" SSR170 CFM
8"Ø
10" x 6" CSR 110 CFM
3-WAY 6"Ø
9"Ø
10" x 6" CSR
100 CFM3-WAYW/CRD
6"Ø
7"Ø
3"Ø
4"Ø
3"Ø
7"Ø
4
E
AB
C
D
J
K
12" x 6" SSR170 CFM
8"Ø
10" x 6" CSR 110 CFM3-WAY 6"Ø
9"Ø
3"Ø
EE
D
H
K
12" x 6" CSR
180 CFM3-WAYW/CRD
8"Ø
8" x 6" CSR 90 CFM
3-WAYW/CRD
8" x 4" CSR
50 CFM3-WAYW/CRD
5"Ø
6"Ø
10"
3"Ø
4"Ø
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M8
1/4" = 1' - 0"
1/4" = 1'-0"
UNIT TYPE B3
1/4" = 1'-0"
UNIT TYPE B3-A
1/4" = 1'-0"
UNIT TYPE B4
1/4" = 1'-0"
UNIT TYPE B4-A
4 OWNERS CHANGES 3-27-2014
4 REVISED
BACKGROUND, B3,B3,A B4, B4A
ADDED NEW UNIT B4B
1/4" = 1'-0"
UNIT TYPE B4-B
5 REVISEDBACKGROUND,
OWNERS CHANGES
5 OWNERS CHANGES 4-21-2014
G
36" x 12"
RAFG
E
B
A
D
D
F
H
I
J
K
K
10" x 6" CSR
160 CFM3-WAYW/CRD
7"Ø
8" x 8" CSR 170 CFM
4-WAYW/CRD
8"Ø
14" x 6" CSR 200 CFM3-WAYW/CRD
8"Ø
10"Ø
4"Ø
3"Ø
3"Ø
8" x 6" CSR 70 CFM3-WAY
5"Ø8" x 6" CSR 60 CFM3-WAY 5"Ø
8" x 6" CSR
60 CFM3-WAY
5"Ø
14" x 6" CSR210 CFM3-WAY
W/CRD
8" x 6" CSR70 CFM3-WAYW/CRD
5"Ø
8"Ø
6"Ø
12" x 12" RAFG
6
6
13
HORIZONTAL FAN COIL UNIT MOUNTED INFURR DOWN AS HIGH AS POSSIBLE.
FAN COIL CEILING ACCESS PANEL. PANELSHALL BE GASKETED AND AIR TIGHT.
SHEETROCK UP TO FURR DOWN ONLY
EXHAUST FAN IN WALL, EXTEND DUCT UP TOJOIST SPACE. TOP FLOOR SHALL HAVE THEOPTION TO ROUTE DUCT DOWN TO JOISTSPACE BELOW.
WALL CAPS, EACH EXHAUST WALL CAP SHALL
MAINTAIN A MINIMUM DISTANCE OF 36" FROMANY OPERABLE OPENING TO THE BUILDINGAND SHALL BE SEALED WEATHER TIGHT.
WATER HEATER BY PLUMBING CONTRACTOR.
DRYER VENT UP IN WALL.
DRYER VENT IN TRUSS/JOIST SPACE. EACH
DRYER VENT SHALL BE 26 GAUGE RIDGEDSMOOTH METAL WITH ALL JOINTS CONNECTEDIN THE DIRECTION OF AIR FLOW.
MAKEUP AIR LOUVER, REFER TO
ARCHITECTURAL UNIT PLANS FORCALCULATIONS AND SIZING.
FIRE DAMPER WITH ACCESS PANEL. ALL FIREDAMPERS SHALL BE INSTALLED INACCORDANCE TO ALL SMACNA AND LOCAL
REQUIREMENTS.
B
A
C
D
E
F
G
H
I
J
MECHANICAL NOTES BY SYMBOL:
EXHAUST VENT IN TRUSS/JOIST SPACE.K
E
H
10" x 6" CSR 160 CFM3-WAY
W/CRD
7"Ø
8" x 8" CSR 170 CFM4-WAY
W/CRD
14" x 6" CSR
200 CFM3-WAYW/CRD
8"Ø
FURR DOWN LEGEND
MECHANICAL CONTRACTOR SHALL VERIFYTHAT ALL DRYER AND EXHAUST VENT HOODS
ARE INSTALLED PER MANUFACTURESREQUIREMENTS AND ARE WEATHER TIGHT.
REFRIGERANT LINE PENETRATION THROUGH ANYPORTION OF THE BUILDING SHALL BE INSTALLEDTO PREVENT ANY ACCESS OF WATER, INSECTS ORINCLEMENT WEATHER REACHING THE INSIDE OF
THE BUILDING ENVELOPE.
RETURN AIR FURR DOWN, MECHANICALCONTRACTOR SHALL VERIFY ALL RETURN AIRFURRING IS AIR TIGHT AND SEPARATE FROMANY NON RETURN FURRING. CONTRACTOR
SHALL ALSO ENSURE THAT RETURN AIR PATHFROM RETURN AIR GRILL TO AIR HANDLER ISCLEAR OF OBSTRUCTIONS THAT WOULD CAUSE
RESTRICTION TO RETURN AIR.
NON RETURN AIR FURR DOWN - SEPERATEFROM FURRING USED FOR RETURN AIR.
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M9
1/4" = 1' - 0"
1/4" = 1'-0"
UNIT TYPE B5
1/4" = 1'-0"
UNIT TYPE B5-A
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUNDS
6 CITY COMMENTS 05-02-2014
13 OWNER CHANGES06-30-2014
E
T
A
D
D
E
H
I
J
J
J
J
K
FG
30" x 12"RAFG
B
C
J
K
12" x 12"
RAFG
12" x 6" CSR 180 CFM
3-WAYW/CRD
8"Ø
8" x 6" CSR 80 CFM
3-WAYW/CRD
5"Ø
12" x 6" SSR180 CFM 8"Ø
12" x 6" CSR 180 CFM3-WAY
W/CRD 8"Ø
9"Ø
10" x 6" CSR 90 CFM
3-WAY
5"Ø
8" x 4" CSR
60 CFM3-WAY
5"Ø
10" x 6" CSR 160 CFM
3-WAYW/CRD
7"Ø
10"Ø
12" x 6" SSR
70 CFM
5"Ø
3"Ø
3"Ø
4"Ø
4
HORIZONTAL FAN COIL UNIT MOUNTED INFURR DOWN AS HIGH AS POSSIBLE.
FAN COIL CEILING ACCESS PANEL. PANELSHALL BE GASKETED AND AIR TIGHT.
SHEETROCK UP TO FURR DOWN ONLY
EXHAUST FAN IN WALL, EXTEND DUCT UP TOJOIST SPACE. TOP FLOOR SHALL HAVE THE
OPTION TO ROUTE DUCT DOWN TO JOISTSPACE BELOW.
WALL CAPS, EACH EXHAUST WALL CAP SHALLMAINTAIN A MINIMUM DISTANCE OF 36" FROMANY OPERABLE OPENING TO THE BUILDING
AND SHALL BE SEALED WEATHER TIGHT.
WATER HEATER BY PLUMBING CONTRACTOR.
DRYER VENT UP IN WALL.
DRYER VENT IN TRUSS/JOIST SPACE. EACHDRYER VENT SHALL BE 26 GAUGE RIDGEDSMOOTH METAL WITH ALL JOINTS CONNECTED
IN THE DIRECTION OF AIR FLOW.
MAKEUP AIR LOUVER, REFER TOARCHITECTURAL UNIT PLANS FORCALCULATIONS AND SIZING.
FIRE DAMPER WITH ACCESS PANEL. ALL FIREDAMPERS SHALL BE INSTALLED IN
ACCORDANCE TO ALL SMACNA AND LOCALREQUIREMENTS.
B
A
C
D
E
F
G
H
I
J
MECHANICAL NOTES BY SYMBOL:
EXHAUST VENT IN TRUSS/JOIST SPACE.K
FURR DOWN LEGEND
MECHANICAL CONTRACTOR SHALL VERIFY
THAT ALL DRYER AND EXHAUST VENT HOODSARE INSTALLED PER MANUFACTURES
REQUIREMENTS AND ARE WEATHER TIGHT.
REFRIGERANT LINE PENETRATION THROUGH ANYPORTION OF THE BUILDING SHALL BE INSTALLEDTO PREVENT ANY ACCESS OF WATER, INSECTS OR
INCLEMENT WEATHER REACHING THE INSIDE OFTHE BUILDING ENVELOPE.
RETURN AIR FURR DOWN, MECHANICALCONTRACTOR SHALL VERIFY ALL RETURN AIR
FURRING IS AIR TIGHT AND SEPARATE FROMANY NON RETURN FURRING. CONTRACTOR
SHALL ALSO ENSURE THAT RETURN AIR PATH
FROM RETURN AIR GRILL TO AIR HANDLER ISCLEAR OF OBSTRUCTIONS THAT WOULD CAUSE
RESTRICTION TO RETURN AIR.
NON RETURN AIR FURR DOWN - SEPERATE
FROM FURRING USED FOR RETURN AIR.
E
A
H
J
J
J
KB
12" x 6" CSR 180 CFM3-WAY
W/CRD 8"Ø
9"Ø
10" x 6" CSR 90 CFM3-WAY
5"Ø
8" x 4" CSR 60 CFM
3-WAY
5"Ø
3"Ø
4"Ø
4
E
A
H
J
J
J
K
B
12" x 6" CSR 180 CFM
3-WAYW/CRD
9"Ø
10" x 903-W
5"Ø
8" x 4" CSR 60 CFM3-WAY
5"Ø
4"Ø
4
G
25" x 12"RAFG
J
D
D
A B
C
C
E
E
F
H
I
K
K
T
T
8" x 8" CSR 110 CFM4-WAYW/CRD
10" x 6" SSR150 CFM
14" x 6" SSR200 CFM
10" x 6" CSR 90 CFM3-WAY
8" x 4" CSR 50 CFM3-WAY
5"Ø
6"Ø
8"Ø
5"Ø
7"Ø
3"Ø
3"Ø
4"Ø
14" x 6" SSR200 CFM
8"Ø
12" x 6" SSR
180 CFM
8"Ø
8" x 6" CSR 70 CFM3-WAY
5"Ø
10" x 6" SSR
150 CFM
7"Ø18" x 12"RAFG
12" x 12"
RAFG
12" x 12"
RAFG
12" x 12"
RAFG
G
25" x 12"RAFG
J
D
D
A B
C
C
E
E
18" x 12"RAFG
F
H
I
K
K
T
T
8" x 8" CSR 110 CFM4-WAY
W/CRD
10" x 6" SSR150 CFM
14" x 6" SSR200 CFM
10" x 6" CSR 90 CFM3-WAY
8" x 4" CSR 50 CFM
3-WAY
5"Ø
6"Ø
8"Ø
5"Ø
7"Ø
3"Ø
3"Ø
4"Ø
14" x 6" SSR200 CFM
8"Ø
12" x 6" SSR180 CFM
8"Ø
8" x 6" CSR 70 CFM3-WAY
5"Ø
10" x 6" SSR
150 CFM
7"Ø
12" x 12" RAFG
12" x 12" RAFG
12" x 12" RAFG
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M10
1/4" = 1' - 0"
1/4" = 1'-0"
UNIT TYPE B6
1/4" = 1'-0"
UNIT TYPE B6-A
1/4" = 1'-0"
UNIT TYPE B6-B
1/4" = 1'-0"
UNIT TYPE C1
1/4" = 1'-0"
UNIT TYPE C1-HC
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND, B6,
B6A, B6B
5 REVISEDBACKGROUND,
OWNERS CHANGES
5 OWNERS CHANGES 4-21-2014
7
6
5
4
3
2
1CLUBHOUSE AIR HANDLER #1 MOUNTED ON RETURN AIR PLATFORM 32" AFG.
1-8"X10" O.A. INTAKE DUCT WITH DAMPER AT RETURN PLENUM, EXTENDTHROUGH WALL TO GRILLE. EXTEND 3/4" CONDENSATE DRAIN TOHUBDRAIN. INSTALL ELECTRONIC HIGH CONDENSATE LEVEL SHUTOFFSWITCH ON SECONDARY CONDENSATE LINE AT COIL.
DUCT SMOKE DETECTOR (TYP)(SEE DETAIL)
CEILING EXHAUST FAN WITH DISCHARGEDUCT THRU WALL TO WEATHER TIGHT WALL CAP.
BALANCING DAMPER
MECHANICAL NOTES BY SYMBOL
36" x 14"RAR
12" x 10"
12" x 10"
12" x 10"DOWN TO
BELOWPLATFORM
18" x 10"
12" x 12" CSR
320 CFM4-WAY
3 - 4' SIDEWALLADJUSTABLE LINEAR
DIFFUSER
2 - 1" SLOTS50CFM PER FT.
10" Ø
8" Ø
8" Ø
8" Ø
8" Ø
OUTSIDEAIR INTAKE
1 - 4' SIDEWALLADJUSTABLE LINEAR
DIFFUSER2 - 1" SLOTS
50CFM PER FT.
8" x 6" SSR80 CFM
1-WAY
6" Ø
12" x 6" CSR190 CFM3-WAY
12" x 12"RAR
12" x 12"RAR
8"ØJUMPERDUCT
8"ØJUMPER
DUCT
12" x 12"RAR
12" x 12"RAR
10" x 6" CSR
140 CFM3-WAY
10" x 6" CSR120 CFM
3-WAY
7" Ø
7" Ø
8" Ø
10" x 10" CSR190 CFM
4-WAY
10" x 10" CSR190 CFM
4-WAY 8" Ø
8" Ø
8" Ø
8" Ø
12" x 6" CSR170 CFM
3-WAY
9" Ø
14" x 10"
AHU # 2
T
T
12" x 18" RETURN AIRDUCT UP FROM RETURN
AIR GRILLE BELOW
12" x 18" RETURN AIRDUCT UP FROM RETURN
AIR GRILLE BELOW
DOWN FLOW AHU # 5
30" x 20"RAR ATCEILING
12" x 18" RETURN AIRDUCT UP TO HVAC
CLOSET ABOVE
1 - 4' SIDEWALLADJUSTABLE LINEAR
DIFFUSER2 - 1" SLOTS
50CFM PER FT.
1 - 4' SIDEWALLADJUSTABLE LINEAR
DIFFUSER2 - 1" SLOTS
50CFM PER FT.
1 - 5' CEILING MOUNTADJUSTABLE LINEAR
DIFFUSER
2 - 1" SLOTS50CFM PER FT.
1 - 5' CEILING MOUNTADJUSTABLE LINEAR
DIFFUSER2 - 1" SLOTS
50CFM PER FT.
1 - 5' CEILINGMOUNTADJUSTABLE
LINEAR DIFFUSER2 - 1" SLOTS50CFM PER FT.
12" x 18" SUPPLY DUCTDOWN FROM HVAC
CLOSET ABOVE
20" x 12"
14" x 12"
9" Ø
9" Ø
8" Ø
9" Ø
8" Ø
T
36" x 24" RAR ABOVE
BASEBOARD INTO RETURNAIR PLENUM UNDER
PLATFORM
12" x 6" SSR230 CFM3-WAY
12" x 6" SSR230 CFM
3-WAY
12" x 6" SSR230 CFM
3-WAY
12" x 6" SSR230 CFM3-WAY
12" x 6" SSR230 CFM3-WAY
T
12" x 6" CSR200 CFM3-WAY
12" x 6" CSR210 CFM
3-WAY8" Ø
8" Ø
20" x 12"
24" x 12"
12" x 6" CSR225 CFM3-WAY
8" Ø
8" Ø
8" Ø
8" Ø
8" Ø
8" Ø
8" Ø
12" Ø
24" x 12" RAR
24" x 12"
10" x 10" CSR185 CFM4-WAY
10" x 10" CSR
185 CFM4-WAY
10" x 10" CSR185 CFM
4-WAY
10" x 10" CSR
185 CFM4-WAY8" Ø
8" Ø
8" Ø
8" Ø
12" x 6" CSR170 CFM3-WAY
8" Ø
8" Ø
12" x 6" CSR170 CFM3-WAY
12" x 12" CSR
470 CFM4-WAY
12" x 12"RAR
10"Ø JUMPERDUCT
12" x 12"RAR
12" x 12"RAR
14" x 8" CSR300 CFM
3-WAY
10" x 6" CSR150 CFM3-WAY
7"Ø 10"Ø
12"Ø
18" x 12"
24" x 24" RAR
24" x 12"
AHU # 4
AHU # 1
THEATER
AEROBICS
COMPUTERROOM
RECEPTION
LEASING
WOMENS
MENS
GREAT ROOM
FITNESS
ASSISTANTMANAGER
GAMEROOM
MANAGER
CLUBHOUSE AIR HANDLER #2 MOUNTED ON RETURN AIR PLATFORM 32" AFG.1-8"Ø O.A. INTAKE DUCT WITH DAMPER AT RETURN PLENUM, EXTEND TOCLOSEST EXTERIOR LOCATION. EXTEND 3/4" CONDENSATE DRAIN TOHUBDRAIN. INSTALL ELECTRONIC HIGH CONDENSATE LEVEL SHUTOFF
SWITCH ON SECONDARY CONDENSATE LINE AT COIL.
OUTSIDEAIR INTAKE
AHU # 3
CLUBHOUSE AIR HANDLER #3 MOUNTED ON RETURN AIR PLATFORM 32" AFG.1-8"Ø O.A. INTAKE DUCT WITH DAMPER AT RETURN PLENUM, EXTEND TOCLOSEST EXTERIOR LOCATION. EXTEND 3/4" CONDENSATE DRAIN TO LAVTAILPIECE. INSTALL ELECTRONIC HIGH CONDENSATE LEVEL SHUTOFF
SWITCH ON SECONDARY CONDENSATE LINE AT COIL.
6
5
6
5
6
6
6
5
EF1
EF2
3" Ø
3" Ø
6" Ø
7
7
8CLUBHOUSE DOWN FLOW AIR HANDLER #5.1-8"Ø O.A. INTAKE DUCT WITH DAMPER AT RETURN PLENUM, EXTENDTO CLOSEST EXTERIOR LOCATION. EXTEND 3/4" CONDENSATE DRAINTO LAV TAILPIECE. INSTALL ELECTRONIC HIGH CONDENSATE LEVEL
SHUTOFF SWITCH ON SECONDARY CONDENSATE LINE AT COIL.
CLUBHOUSE AIR HANDLER #4 MOUNTED ON RETURN AIR PLATFORM 32" AFG.
1-8"Ø O.A. INTAKE DUCT WITH DAMPER AT RETURN PLENUM, EXTEND TOCLOSEST EXTERIOR LOCATION. EXTEND 3/4" CONDENSATE DRAIN TOHUBDRAIN. INSTALL ELECTRONIC HIGH CONDENSATE LEVEL SHUTOFFSWITCH ON SECONDARY CONDENSATE LINE AT COIL.8 3
4
12
4
DOWNDRAFT EXHAUST
SYSTEM. EXTEND 6"EXHAUST DUCT BELOWSITTING BOOTH ANDTERMINATE AT WALLCAP WITH BACKDRAFT
DAMPER
7
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M11
3/16" = 1' - 0"
CLUBHOUSE - FIRST FLOOR - HVAC
3/16" = 1'-0"
CLUBHOUSE - SECOND FLOOR - HVAC
3/16" = 1'-0"
4 OWNERS CHANGES 3-27-2014
4REVISED BACKGROUNDS
7 05-16-2014FIRE COMMENTS
SANYO WALL
MOUNTED A/C
SANYO CONDENSING UNITBROAN THROUGH WALL
EXHAUST FAN MODEL. #512M
BROAN THROUGH WALLEXHAUST FAN MODEL. #L300MG
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LA
ND
MA
RK
SA
N A
NT
ON
IO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTEN
PERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USED
ON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M12
1/4" = 1' - 0"
MAINTENANCE BUILDING
1/4" = 1'-0"
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
N/A
M13
System No. F-C-7001
(Formerly System No. 169)
F Rating - 1 Hr
T Rating - 1/2 Hr
1. Floor-Ceiling Assembly - The 1 hr fire-rated wood joist floor-ceiling assembly shall
be constructed of the materials and in the manner specified in the individual L500 Series
Floor-Ceiling Designs in the UL Fire Resistance Directory, as summarized below:
A. Flooring System - Lumber or plywood subfloor with finish floor of lumber, plywood
or Floor Topping Mixture* as specified in the individual Floor-Ceiling Design. Max diam
of opening is 11 in.
B. Wood Joists - Nom 2 by 10 in. lumber joists spaced 16 in. OC with nom 1 by 3 in.
lumber bridging and with ends firestopped.
C. Gypsum Board* - Nom 4 ft wide by 5/8 in. thick as specified in the individual
Floor-Ceiling Design. Max diam of opening is 11 in.
1.1 Chase Wall (Optional, not shown) - The through penetrants (Item No. 2) shall be
routed through a 1 hr fire-rated single, double or staggered wood stud/gypsum
wallboard chase wall constructed of the materials and in the manner specified in the
individual U300 Series Wall and Partition Designs in the UL Fire Resistance Directory and
shall include the following construction features:
A. Studs - Nom 2 by 6 in. or double nom 2 by 4 in. lumber studs.
B. Sole Plate - Nom 2 by 6 in. or parallel 2 by 4 in. lumber plates, tightly butted.
C. Top Plate - The double top plate shall consist of two nom 2 by 6 in. or two sets of
parallel 2 by 4 in. lumber plates, tightly butted. Max diam of opening is 5 in.
D. Gypsum Board* - Thickness, type, number of layers and fasteners shall be as
specified in individual Wall and Partition Design.
2. Steel Vent Duct - Nom 4 in. diam (or smaller) No. 30 gauge (or heavier) galv steel
vent duct or nom 10 in. diam (or smaller) No. 28 gauge (or Heavier) galv steel vent
duct. Diam of openings to be max 1 in. larger than outside diam of duct. Duct to be
installed approx midway between wood joists and installed either concentrically or
eccentrically in opening. The annular space between the duct and the periphery of
opening shall be min 0 in. (point contact) to max 1 in. Duct to be rigidly supported on
both sides of floor-ceiling assembly.
3. Fill,Void or Cavity Materials* - Caulk or Sealant - Min 3/4 in. thickness of fill
material applied within the annulus, flush with top surface of floor or sole plate. Min 5/8
in. thickness of fill material applied within the annulus, flush with bottom surface of
ceiling or top plate. An additional min 1/4 in. crown of fill material applied to perimeter
of duct at its egress from the top of flooring and underside of ceiling or from top of sole
plate and underside of top plate.
3M COMPANY - CP 25WB+ caulk or FB-3000 WT sealant
*Bearing the UL Classification Marking
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
N/A
M14
DRYERBOX MODEL 350
DETAILS FOR 4" STRUCTURAL WALL
SCALE
MATERIAL
INSTALLATION
PRODUCT
DRYERBOX
REFER TO NOTES
SEE DETAIL
DATE
DRYERBOX DETAIL
DRYER VENTING: MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR
RUNNING ALL DUCTWORK FOR THE DRYER EXHAUST SYSTEM. ALL
CONCEALED DRYER DUCTING MUST BE RIGID METAL (GALVANIZED OR
ALUMINUM) MINIMUM OF 4" IN DIAMETER, SMOOTH 30 GA. CLEAN,
UNOBSTRUCTED, FRICTIONLESS DUCTS (NO FLEXIBLE DUCT ALLOWED IN
CONCEALED AREAS). SEAL ALL JOINTS WITH FOIL BACKED PRESSURE
SENSITIVE DUCT TAPE MEETING THE REQUIREMENTS OF UL 181. DUCT
JOINTS SHALL BE INSTALLED SO THAT THE MALE END OF THE DUCT
POINTS IN THE DIRECTION OF THE AIRFLOW. DO NOT USE RIVETS OR
SCREWS IN THE JOINTS OR ANYWHERE ELSE IN THE DUCT AS THESE WILL
ENCOURAGE LINT COLLECTION.
DRYERBOX® RECEPTACLE (WWW.DRYERBOX.COM) SHALL BE METAL AND
BE INSTALLED AS LOW AS POSSIBLE AS TO PERMIT THE PROPER AND SAFE
COLLECTION OF THE DRYER TRANSITION HOSE. DRYERBOX SHOULD BE
RESTING ON THE BOTTOM PLATE AND BE LOCATED AT OR NEAR THE
CENTERLINE OF THE PROPOSED DRYER APPLIANCE. RIGID DUCT SHOULD
PENETRATE DRYERBOX PORT 2 INCHES TO PROVIDE FOR FUTURE
CONNECTION AND STORAGE OF TRANSITION HOSE. BASEBOARD SHALL BE
"BUTTED" UP TO THE FIXED EXTENSION RIM AND SLIGHTLY BACK-CUT.
DRYERBOX SHOULD BE CAULKED AND THEN PAINTED WITH THE TRIM
PAINT. FOR USAGE IN A ONE-HOUR WALL ASSEMBLY, UL REQUIRES THAT
BATT INSULATION BE STUFFED AROUND THE DRYERBOX AND IN THE
ENTIRE WALL CAVITY CELL.
DRYERBOX INSTALLATION
RIDGID PIPE NOT TO EXCEED
2" THROUGH DRYER BOX
FLEX TRANSITION
HOSE
MOUNT DRYERBOX AS LOW AS
POSSIBLE UNLESS YOU HAVE A
PEDASTAL OR STACKABLE DRYER
FIRRING STRIP ON
2X4
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
N/A
M15
MATCH LINE
MATCH LINE
MATCH LINE
MAT
AREA "A"SECTION 1
AREA "B"
AREA "A"SECTION 1
AREA "A"SECTION 1
MATCH
LINE
AREA"A"
SECTION
"1"
AREA"A"
SECTION
"2"
AREA"B"
MATCH
LINE
MATCH
LINE
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDM
ARK SAN A
NTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M16
1/8" = 1' - 0"
BUILDING 1 - AREA "A" - SECTION "1" - CONDENSING UNITS
1/8" = 1'-0"
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND
13 OWNER CHANGES06-30-2014
ADJUSTEDCONDENSING UNITLOCATIONS - REFERTO ARCHITECTURAL
PLANS FORDIMENSIONS
13
MATCH
LINE
AREA"A"
SECTION"1"
AREA"A"
SECTION"2"
AREA"B"
MATCH
LINE
MATCH
LINE
MATCH LINE
MATCH LINE
AREA "B"
AREA "A"SECTION 2
AREA "A"SECTION 1
AREA "A"
SECTION 2
AREA "A"SECTION 1
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDM
ARK SAN A
NTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M17
1/8" = 1' - 0"
BUILDING 1 - AREA "A" - SECTION "2" - CONDENSING UNITS
1/8" = 1'-0"
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND
13 OWNER CHANGES06-30-2014
ADJUSTEDCONDENSING UNITLOCATIONS - REFERTO ARCHITECTURAL
PLANS FORDIMENSIONS
13
MATCH
LINE
AREA"A"
SECTION"1"
AREA"A"
SECTION"2"
AREA"B"
MATCH
LINE
MATCH
LINE
MATCH LINE
MATCH LINE
AREA "B"
AREA "B"
AREA "B"
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDM
ARK SAN A
NTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M18
1/8" = 1' - 0"
BUILDING 1 - AREA "B" - CONDENSING UNITS
1/8" = 1'-0"
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND
13 OWNER CHANGES06-30-2014
ADJUSTEDCONDENSING UNITLOCATIONS - REFERTO ARCHITECTURAL
PLANS FORDIMENSIONS
13
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M19
1/8" = 1' - 0"
BUILDING 2 - CONDENSING UNITS
1/8" = 1'-0"
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND
13 OWNER CHANGES06-30-2014
ADJUSTEDCONDENSING UNITLOCATIONS - REFERTO ARCHITECTURAL
PLANS FORDIMENSIONS
13
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M20
1/8" = 1' - 0"
BUILDING 3 - CONDENSING UNITS
1/8" = 1'-0"
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND
13 OWNER CHANGES06-30-2014
ADJUSTEDCONDENSING UNITLOCATIONS - REFERTO ARCHITECTURAL
PLANS FORDIMENSIONS
13
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M21
1/8" = 1' - 0"
BUILDING 4 - AREA " A " - CONDENSING UNITS
1/8" = 1'-0"
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND
13 OWNER CHANGES06-30-2014
ADJUSTEDCONDENSING UNITLOCATIONS - REFERTO ARCHITECTURAL
PLANS FORDIMENSIONS
13
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M22
1/8" = 1' - 0"
BUILDING 4 - AREA " B " - CONDENSING UNITS
1/8" = 1'-0"
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND
13 OWNER CHANGES06-30-2014
ADJUSTEDCONDENSING UNITLOCATIONS - REFERTO ARCHITECTURAL
PLANS FORDIMENSIONS
13
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M23
1/8" = 1' - 0"
BUILDING 5 - AREA " A " - CONDENSING UNITS
1/8" = 1'-0"
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND
13 OWNER CHANGES06-30-2014
ADJUSTEDCONDENSING UNITLOCATIONS - REFERTO ARCHITECTURAL
PLANS FORDIMENSIONS
13
18 OWNERS CHANGES 9-08-2014ADJUSTED
CONDENSING UNITLOCATIONS DUE TOADDITION OF UNITS
AND TERRACEREVISION
18
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M24
1/8" = 1' - 0"
BUILDING 5 - AREA " B " - CONDENSING UNITS
1/8" = 1'-0"
4 OWNERS CHANGES 3-27-2014
4 REVISEDBACKGROUND
13 OWNER CHANGES06-30-2014
ADJUSTEDCONDENSING UNITLOCATIONS - REFERTO ARCHITECTURAL
PLANS FORDIMENSIONS
13
3
JRFASSOCIATES
SCALE
3620 Winding Way
Round Rock Texas 78664
512-970-9478 Ph
ISSUE DATE
SHEET NUMBER
PROJECT NUMBER
1322013
05-27-2014
LANDMARK SAN ANTONIO
C 2010 BY JRF ASSOCIATESALL RIGHTS RESERVED.
THE DESIGNS DEPICTED HEREIN ARE THE SOLEPROPERTY OF JRF ASSOCIATES AND MAY NOT BEREPRODUCED IN ANY FORM WITHOUT WRITTENPERMISSION. ALL DESIGNS ARE BASED ON THEINFORMATION FROM OTHERS AND TO BE USEDON LANDMARK SAN ANTONIO APARTMENTS
Firm registration number
f-15222
Automation Engineering
PERMIT SET
M25
1/8" = 1' - 0"
BUILDING 5 - FOURTH FLOOR TERRACE / RR
1/8" = 1'-0"
3 02-21-2014OWNERS CHANGES
18 OWNERS CHANGES 9-08-2014
18
UPDATEDTERRACE
BACKGROUND