lamp start run up time and flicker test

9
Lamp Start, Run-up time and Flicker Test (LSRF-1) Brochure Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong Kong Tel: 00852-68852050 Fax: 00852-30785638 Email: [email protected] Lisun Electronics (Shanghai) Co., Ltd Add: Room 1210, No. 9 Building, Jiangqiao Wanda Plaza, Hexuan Road, Jiading District, Shanghai, 201803, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: [email protected] Lisun Electronics Inc. (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: [email protected] Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: [email protected] Lead in CFL & LED Test Instruments

Upload: amanda-jiang

Post on 18-Dec-2015

15 views

Category:

Documents


1 download

DESCRIPTION

To meet EU ErP requirements, IEC60969 Self-ballasted Lamps for General Lighting Services Performance requirements and Energy Star about Lamp Start, Run-up Time and Flicker Test.

TRANSCRIPT

  • Lamp Start, Run-up time and Flicker Test

    (LSRF-1)

    Brochure

    Global Office of Lisun Electronics Inc. http://www.Lisungroup.com

    Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong Kong Tel: 00852-68852050 Fax: 00852-30785638 Email: [email protected] Lisun Electronics (Shanghai) Co., Ltd Add: Room 1210, No. 9 Building, Jiangqiao Wanda Plaza, Hexuan Road, Jiading District, Shanghai, 201803, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: [email protected] Lisun Electronics Inc. (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: [email protected] Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: [email protected]

    Lead in CFL & LED Test Instruments

  • Lisun Electronics Inc. [email protected] www.Lisungroup.com

    Dated 14th December, 2012, the EU officially released the (EU) NO 1194/2012 rulesImplementing rules of the European Parliament and the EU Council Directive 2009/125/EC on the eco-design requirements of directional lights, LED lights and related equipment requirements.Compared with European Parliament and Council Directive 2005/32/EC implementing rules for non-directional household lamps eco-design requirementswhich posted by the European Commission Regulation (EC) NO 244/2009 Regulations dated 18th March, 2009, the new rules have complete mandatory and eco-design requirements. Start and Run-up time as the two indicators functional requirements in the industry has been more emphasis by manufacturers. To meet EU ErP requirements, IEC60969 Self-ballasted Lamps for General Lighting Services Performance requirements and Energy Star about Lamp Start, Run-up Time and Flicker Test. LISUN developed ErP test system, the system hardware consists of PH3000 and LSP-500VAC; the software consists of LST-3000 Lamp Start and Run-up Time Test and FLK-3000 Lamp Flick Test.

    1. Transit Photometer (PH3000) The Luminous flux, illuminance and Brightness are the most basic physical quantity in photometric test. PH3000 Transit Photometer is developed base on rapid sampling techniques. It applied with 12 Bytes, the maximum sampling rate of 10M Hz high-speed A / D which can be achieved rapidly high speed measurement of varying light photometric parameters. Combined with computer can record the sampled waveform. The PH3000 also can used as normal illuminance meter, it can measuring luminous flux, brightness, illuminance and photometric parameters.

    Specification: Photocurrent measurement range: 0.005x10-7~19999x10-8A; the measurement range of

    luminous flux, brightness and illuminance depend on the sensitivity of acquisition and detector; Users can achieve calibrate and zero through the instrument panel keyboard; 12 A / D conversion accuracy, five digital display; Fourth gear range automatically converted tenfold; USB and RS232 communicate ports; Instrument level: Class 1. Sampling rate: setting the fastest 20kS/s Record: working with computer software, the record width can be set;

    -Page 1 -

  • Lisun Electronics Inc. [email protected] www.Lisungroup.com

    2. Programmable AC Power Source Meter (LSP-500VAC) LSP-500VAC Programmable AC Power Source combined with high power, low harmonic, high stability pure sine wave and power meter functions. Its suitable to power on electronic ballast, CFL and low power household appliances. The LSP-500VAC has following characteristics: Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform

    feedback technology, low distortion power; Applied with entire cycle high-precision measurement technology and high-speed sampling

    technologies , panel of instrument will directly and accurately displays the power output of the voltage, frequency, current, active power and power factor to achieve the integration of the source table;

    Applied with SCM control and measurement technology, high intelligence; Applied with zero output impedance technology, the output equivalent impedance is almost zero

    and further improve the stability of power supply; Applied with isolated floating output technology, the power output and input have good isolation,

    floating output, conducive to make sure power itself safety and operator's safety; Perfect voltage, current anomalies and overheating protection, improve the reliability of power

    supply; Applied with power limiting technology to avoid strong interference on the power grid and other

    electrical equipment, while facilitating reliable operation of the power supply itself; The input voltage can be option via a toggle switch of panel mains 110V/220V; The initial phase and end phase of the output voltage waveform can be set0-359(1); Measurement process can be programmed to control(1 to 50 memory groups, 1 to 9 steps for

    each memory group);

    Specification: Input voltage: 110VAC or 220VAC10% 50/60Hz; Output frequency setting: 45.00-500.00Hz; Output phase setting: 0-359(1); Output voltage setting: AC 0.0-300.0V; Maximum allowable output current: 0-150V(4.2A)0-300V(2.1A);

    -Page 2 -

  • Lisun Electronics Inc. [email protected] www.Lisungroup.com

    The total voltage distortion: 0.3(No load or full load resistive load); Voltage stability(0.1/30 minute); Equivalent resistance(0.1(Zero-resistance design); Load Regulation: 0.1; Frequency stability: 0.05/30 minute; Meter display

    Item Frequenc

    y Voltage Current

    Peak Current

    Power Power Factor

    Range 45-500Hz 0.1-300V 0.001-4.200A 0.0-5.9A 0.1-1200W 0.000-1.000

    Resolution 0.1Hz 0.1V 0.001A 0.1A 0.1W 0.001

    Accuracy 0.05%reading

    (0.4% reading)

    (0.4% reading)

    (1% reading)

    (0.4% reading)

    (0.001% reading)

    3. New Design Integrating Sphere Due to the LED luminaries such as LED street luminaries developed, to do 4 geometry testing, it is hard to be hold in the traditional integrating sphere design. To solve this problem, Lisun design a new kind of sphere.

    1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as T5/T8/T12 and all kinds of luminaries 2. The hold base can be installed in the ceiling or down, it can be adjusted the height 3. Hold base has four power cables connect to the outside Power Supply and max is 5KW

    Specification: Diameter: 0.3m, 0.5m, 1.0m, 1.5m, 1.75m, 2.0m, 2.5m and 3.0m The painting of integrating spheres is according to CIE Pub.No.84(1989)

    -Page 3 -

  • Lisun Electronics Inc. [email protected] www.Lisungroup.com

    BaSO4 coating: ()0.96(450nm~800nm) and ()0.92(380nm~450nm) Fine diffuse reflection: Reflectance0.8 and accuracy of ()

  • Lisun Electronics Inc. [email protected] www.Lisungroup.com

    6. Optical Fiber

    1.5m length Connect the Spectroradiometer and integrating sphere

    The next pages are the test report:

    -Page 5 -