labour legacy - kth sales€¦ · ppt file · web view · 2013-07-08pump designed as a self...
TRANSCRIPT
LaBour - LPLA/LHLASelf Primer PumpSelf Primer Pump
LPLA/LHLA Design
Capacities: 500 GPM (114m3/hr)
Head (max): 300 Ft (90 m)
Temperature (max): 500°F (245°C)
Materials:
Options
DI, 316SS, CD4MCU, Alloy 20, Hast, Monel, Ni., & Ti Mag Drive (MPL)
How it all started
Hydrobalance
LHLA/LPLA is Born
++==
Why change “the perfect pump”
• Mechanical Seal developmentMechanical Seal development– Stricter shaft tolerancesStricter shaft tolerances– Larger stuffing boxLarger stuffing box
• Ease of maintenanceEase of maintenance– Back Pull Out DesignBack Pull Out Design
• Shaft stiffness (L3/d4)Shaft stiffness (L3/d4)• Bearing design (7000 series Bearing design (7000 series
duplex)duplex)
OLD vs NEW STUFFING BOX DESIGNLHLA/LPLALHLA/LPLADHL/DPLDHL/DPL
L3/d4 (widely accepted is 60 max)
LL
dd
Group S Comparison
LHLALHLA DHLDHL 8796S8796S
Shaft dia.Shaft dia. 1.38”1.38” 1.0”1.0” 1.13”1.13”Imp. Imp. OverhangOverhang
6”6” 8.38”8.38” 6.1”6.1”
L3/d4L3/d4 60.460.4 587587 143143
Thrust Thrust brgbrg
73077307 207W207W 53065306
Discharge ArrangementLLHHLALA LLPPLALA
H = HorizontalH = Horizontal
P = PerpendicularP = Perpendicular
Models
With TrapWith Trap
Less TrapLess Trap
LHLALHLA LPLALPLA
Features & Benefits - LPLA/LHLA Liquid End
ANSI (LVA/TFA ) Back ANSI (LVA/TFA ) Back Pull Out Power EndPull Out Power End
LaBour’s HYDRO-BALANCELaBour’s HYDRO-BALANCEguarantees suction liftsguarantees suction lifts
of up to of up to 25 feet25 feet
Duplex AngularDuplex AngularThrust BearingThrust Bearing
Heavy Duty 316SS Heavy Duty 316SS or higher Alloy Shaftor higher Alloy Shaft
Lip Seals Standard Lip Seals Standard (Optional Lab. Seals)(Optional Lab. Seals)
External ImpellerExternal Impelleradjustment using jack boltsadjustment using jack bolts
AND shimsAND shims
DPL/DHL ‘Wet End’DPL/DHL ‘Wet End’
LHLA/LPLA Features• Considerably larger trap volumeConsiderably larger trap volume• Modular construction (you only replace Modular construction (you only replace
what is worn).what is worn).• Pump designed as a self primer (not an Pump designed as a self primer (not an
ANSI pump with trap)ANSI pump with trap)• Circular casing design (eliminating air Circular casing design (eliminating air
pockets)pockets)• All pumps tested for 20” vacuum All pumps tested for 20” vacuum
minimumminimum
Features & BenefitsStuffing Box Options (with or without Spiral Trac)
Standard Bore
Big Bore Taper Bore
Self Priming Cycle
1. Fill pump with 1. Fill pump with initial priming initial priming
charge.charge.
2. Start pump, impeller pulls 2. Start pump, impeller pulls liquid from trapliquid from trap
3. Mixture of Air/Liquid is expelled3. Mixture of Air/Liquid is expelled into the separator.into the separator.
4. Air is expelled thru discharge.4. Air is expelled thru discharge.
6. Cycle continues until all air is 6. Cycle continues until all air is evacuated from line.evacuated from line.
5. Liquid re-enters casing/trap thru5. Liquid re-enters casing/trap thrusecond throat to priming chamber.second throat to priming chamber.
Competition
• Gorman Rupp (industrial Gorman Rupp (industrial applications)applications)
• Flowserve (Durco)Flowserve (Durco)• GouldsGoulds• ANSI Mag (lined mag drive)ANSI Mag (lined mag drive)
Competition ComparisonManf. LaBour
LHLA/LPLA Peerless 8796
Goulds 3796
Duriron/ Flowserve
Dean Pump pHP 2110 & 230
# of Sizes
7
6
7
7
6
Service Range
500 GPM 300 ft
700 GPM 400 Ft
1250 GPM 430 Ft
1400 GPM 400 Ft
700 GPM 400 Ft
ANSI B73.1 Parts
Back-Pullout Less
Impeller
Back-Pullout Assembly
Back-Pullout Assembly
Back-Pullout Assembly
Back-Pullout Assembly
Volute Type
Repl. Suction Head
Repla Inner Volute
One Piece
One Piece One Piece
Static Suction Lift
25 Ft
20 Ft
20 Ft
20 Ft
20 Ft
LHLA/LPLA Pump Applications
• Vacuum Filtration (Komline Vacuum Filtration (Komline Sanderson, Sanderson, Siemens, US Filter)Siemens, US Filter)
• SumpsSumps• Tank Car UnloadingTank Car Unloading• Day Tank TransferDay Tank Transfer• Mine de-wateringMine de-watering
Tank Car Unloading
Tank Unloading
Komline Sanderson Vacuum Drum Filter
Vacuum Filtration Systems
‘‘A’A’
‘‘E’E’
‘‘B’B’
‘‘C’C’‘‘D’D’
‘‘A’A’ ‘‘C’C’ ‘‘D’D’
‘‘B’B’‘‘E’E’
‘‘F’F’
20”Hg20”Hg
‘‘D’D’‘‘A’A’
‘‘B’B’
‘‘E’E’
‘‘F’F’ ‘‘C’C’
Trouble Shooting Self Priming Pumps
• No Initial Priming ChargeNo Initial Priming Charge• Wrong Direction of RotationWrong Direction of Rotation• Air leaks in the suction lineAir leaks in the suction line• Discharge Check Valve without bleed lineDischarge Check Valve without bleed line• Suction lift too high (high S.G. or friction loss)Suction lift too high (high S.G. or friction loss)• Loss of Priming Charge Loss of Priming Charge • Low speedLow speed• Foaming liquid (does not release air well)Foaming liquid (does not release air well)• Packing type not designed for vacuum servicePacking type not designed for vacuum service• Wear or CorrosionWear or Corrosion
LaBour was the FIRST (and still is the) Premier Self Priming Pump Manufacturer.
Questions? Opportunities?Questions? Opportunities?