laboratory test of fbg interrogators for wind turbine blade monitoring

22
Load measurements of blades Fibre Optics, ready for implementation? Theo Verbruggen Wind Turbine Condition Monitoring Workshop, October 8-9, 2009

Upload: phungbao

Post on 27-Dec-2016

223 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Laboratory test of FBG interrogators for wind turbine blade monitoring

www.ecn.nl

Load measurements of bladesFibre Optics, ready for implementation?

Theo VerbruggenWind Turbine Condition Monitoring Workshop, October 8-9, 2009

Page 2: Laboratory test of FBG interrogators for wind turbine blade monitoring

2 16-10-2009

Contents

• Applications• Principles• Suppliers• Tests• Hardware developments• Software developments• Conclusions

Page 3: Laboratory test of FBG interrogators for wind turbine blade monitoring

3 16-10-2009

Applications of blade load measurments

• Load measurements for certification

• Turbine control• Blade monitoring• Operation and

maintenance

Blade load measurements can be used for :

Page 4: Laboratory test of FBG interrogators for wind turbine blade monitoring

4 16-10-2009

Principles of FBG-based measurements

Page 5: Laboratory test of FBG interrogators for wind turbine blade monitoring

5 16-10-2009

Principles

TDM: Time Division multiplexing

WDM: Wavelength Division Multiplexing

Page 6: Laboratory test of FBG interrogators for wind turbine blade monitoring

6 16-10-2009

Suppliers

• Smart Fibres TDM

• Insensys TDM

• HBM WDM

• (Micron Optics) WDM

Page 7: Laboratory test of FBG interrogators for wind turbine blade monitoring

7 16-10-2009

User experienceWhat is demonstrated…

Page 8: Laboratory test of FBG interrogators for wind turbine blade monitoring

8 16-10-2009

User experienceOr even more...

Page 9: Laboratory test of FBG interrogators for wind turbine blade monitoring

9 16-10-2009

User experienceAnd this are the details….

Page 10: Laboratory test of FBG interrogators for wind turbine blade monitoring

10 16-10-2009

User experience

•Inaccuracies in strain•Large differences foropposite locations

•Spikes / missing data•Strain modulation on temperature measurements

•Unreliable instrumentation•Complex repair due to required skills and tools

•Long installation time Still promising!But how to proceed?

Page 11: Laboratory test of FBG interrogators for wind turbine blade monitoring

11 16-10-2009

Still promising!

But how to proceed?

• Selection of reliable interrogator which meets requirements for in house developments and on site testing

• Development of user friendly sensor assembly, suitable for on site installation

• Development of user friendly data processing and interface

Page 12: Laboratory test of FBG interrogators for wind turbine blade monitoring

12 16-10-2009

Selection of interrogator

• Accuracy / resolution / long term stability

• Thermal sensitivity• Acceleration / environmental

conditions• Stability during operation /

polarization effects• Reliability / robustness

Reference grating (AOS)

Page 13: Laboratory test of FBG interrogators for wind turbine blade monitoring

13 16-10-2009

Accuracy / resolution

Single micro strain simulator

Page 14: Laboratory test of FBG interrogators for wind turbine blade monitoring

14 16-10-2009

Thermal sensitivity

Climate room

Page 15: Laboratory test of FBG interrogators for wind turbine blade monitoring

15 16-10-2009

Acceleration

Page 16: Laboratory test of FBG interrogators for wind turbine blade monitoring

16 16-10-2009

Polarization

Page 17: Laboratory test of FBG interrogators for wind turbine blade monitoring

17 16-10-2009

Remarks interrogator • Required accuracy not ensured• Long term stability not ensured• Thermal effects found• Acceleration effects minimal• Polarization effects (Strong!)• Reliability / robustness• Strong sensitivity for Bragg grating properties• Strong effects due to attenuation

But we made our choice for our sensor development

Page 18: Laboratory test of FBG interrogators for wind turbine blade monitoring

18 16-10-2009

Sensor developments

• Complicated installation- Skilled personnel / not certified- Special tools

• Time consuming- Gluing process- Curing time and fixation

• Result- Not robust- Prone to damage

Experience:

• Inaccuracies- Strain- Temperature

Page 19: Laboratory test of FBG interrogators for wind turbine blade monitoring

19 16-10-2009

Sensors development

Requirements: • Life time > 20 years• Easy installation• No drift• Temperature compensation• No (re-)calibration• Easy replaceable• Robust

These requirements are met by the ECN sensor development

Page 20: Laboratory test of FBG interrogators for wind turbine blade monitoring

20 16-10-2009

Software development (Blade monitoring)

Purpose• Fully automatic• Very limited data to be

stored• Robust to measurement

faults• Applicable for various

platforms• Applicable for various

turbines• Auto-reporting / warning• Friendly user interface

Page 21: Laboratory test of FBG interrogators for wind turbine blade monitoring

21 16-10-2009

Conclusions

• Load measurements are essential for various wind applications

• Fibre Bragg grating is still promising and still expensive

• Users friendly components still required• Data processing / reduction essential for

monitoring applications

Page 22: Laboratory test of FBG interrogators for wind turbine blade monitoring

22 16-10-2009

Thank you for your attention!