Photovoltaik
IKS
IKS Photovoltaik GmbH
An der Kurhessenhalle 16b
34134 Kassel / Germany
Phone ++49 / (0)561 / 9 53 80 50
Fax ++49 / (0)561 / 9 53 80 51
www.iks-photovoltaik.de
Photovoltaic – Trainingsystem for vocational and advanced training
plus module stand. Using a dimmable spotlightwhich is vertically as well as horizontally movablefixed to an outrigger, seasonal daily curves caneasily be simulated.
Additional options are the change of slope angleand the simulation of the influence of irradiation andtemperature on the characteristic curve of a PV-module.
To ensure a reproducibility of measurements andnot to depend on the weather, a PV-modulesimulator was developed, which exactly simulatesthe behaviour of a PV-module. The short circuitcurrent can be adjusted.
What a pupil ortrainee can workout on his own inpractice orientedlabscale experim-ents, is trans-ferable to realsystems withoutproblems.
The Solar branchis one of theimportant growthmarket of thef u r t u r e . T h enumber of jobsg r o w s , t h ed e m a n d o fspecialists andexecutive staffsi n c r e a s e scontinuous.For this reasonwor ldwide thevocational andadvanced trainingin the field ofphotovoliiac willbecome more andmore important.
Development
Application
Construction
In cooperation with the ISET - Institut für SolareEnergieversorgungstechnik e. V. (now: Frauen-hofer Institut für Windenergie und Energiesystem-technik IWES) in Kassel the company IKS Photo-voltaik developed the Photovoltaic-TrainingsystemSolartrainer profi.
The PV-Trainingsystem is suited for the instructionschools, vocational training Schools, training
centres, evening classes and universities.Supported learning objectives can be electrical andsystem engineering , construction, mode ofoperation, connecting and installation of PV-plants.It can be used both to the supplementarydemonstration of lessons and courses as well as forthe use in practical training
The system consists of individual plugin units eachwith components for different experimentalarrangements. The plugin units are put in therackside and connected according to the demand.The conception of the system allows indoor andoutdoor experimentsIndoor experiments are easily possible amongothers because of the system included PV-module
at
.
ProfiPhotovoltaik
IKS
FlexibleThe modular conception of thesystem allows the selection ofthe plug-in units and compo-nents for the different trainingobjectives.The at any time possibleenlargement and integration ofnew technology assure a systemthat is always state of-the-art.
Instructional materialsAn experimental instruction aswell as two developed trainingsessions are available.GermanEnglishSpanishFrench
Experiments
The basic principles of photovoltaics considering the influence ofdifferent parameters can also be imparted as the application of directconnected small systems, the mains behaviour of stand alonesystems and the especially for craftsmen very important line poweredoperation mode:
Characteristic curve of a diode, respectively adiode series
Characteristic curve of a solar module (I/U)and (U/P), MPP
Characteristic curve of a solar module (I/U)depending on irradiation
Characteristic curve of a solar module (I/U)depending on temperature
Power output of a solar module dependingOn the angle of incidence of the light
Simulation: Power output of a solar moduldepending on the position of the sun (morningto evening / winter- and summertime)
Series connection of solar modules
Parallel connection of solar modules
Series connection of solar modules andshadowing without bypass-diode
Series connection of solar modules andshadowing with bypass-diode
operation moDifferent operation modes and directions of electric energypower flow. Calculation of the efficiency (inverter)
Stand alone systems DC and AC. Different
Integration of outdoor solar module
n
n
n
n
n
n
n
n
n
n
n
n
n
e
Grid parallel de
operation modes
The listing does not contain all experimentswhich are possible to carry out.The possibility of carrying out the experiments isdepending on the equipment.Technical changes reserved 2014-06
ProfiPhotovoltaik
IKS
Profi
ST 01Solar ModuleConnection Indoor
For connecting the solarmodule of “ST 14 modulestand” to the socket on thefront. The two front socketsof the schematically shownsolar module can beconnected to a variable load(e.g. ST 20 B). Measuring ofvoltage and current.
ST 02Solar Module Simulated
Solar module simulator for theexact simulation of a solarmodule.Short circuit current can beadjusted in steps or variably.Parallel and series connectionpossibleSwitchable bypass diode.Mains connection 230 V / 50-60Hz.Open circuit voltage 23.1 V,short circuit current 0 -1.5 A,rated power 24 Wp
ST 03Generator Terminal Box
For the parallel connectionof 4 solar modules/simulators each via onediode onto one output.Overvoltage protectionWithout function. Max.current per input 24 V/3 ADC-disconnector.
ST 07AC Load Connection
For connection to the mains (via"ST 13 Mains connection) or toan inverter island grid (“ST 06 /ST 06 A”) and operation ofalternating current loads ofmax. 450 WAvailable versions:230 V / 50-60 Hz115 V / 60 Hz
ST 04Solar Charge Controller
For monitoring of the state ofcharge state of the battery.Controls the loading processand the connection anddisconnection of loads(low voltage disconnection).Operation status on LCDdispay.Rated voltage 12 V/max 8 A
ST 05 O / ST 05 DInverter Grid Connection
Transforms direct currentinto sinusoidal alternatingcurrent, single-phase feed-in,line-commutated. Input28 - 50 V DC, MPP-trackingAC power approx. 110 WAvailable versions:230 V / 50 Hz (ST 05 O /ST 05 D)230 V / 60 Hz (ST 05 D)115 V / 60 Hz (ST 05 D)
ST 06 RInverter Island Grid
Transforms direct current intorectangular alternating current foroperation of an island gridsystem. Input 12 V DC/8 A,output 230 V / 50 Hz.AC power approx. 100 W
ST 06 SInverter Island Grid
Transforms direct currentinto sinusoidal alternatingcurrent for operation of anisland grid system.Input 12 V DC/8 AAC power approx. 100 WAvailable versions:230 V / 50 Hz230 V / 60 Hz115 V / 60 Hz
Photovoltaik
IKS
Profi
ST 13Mains Connection
Three-phase AC connection forconnection of the public grid viaa 5-pole CEE coupling 16 Ato the training system.Adapter cable for single-phaseavailable.
ST 09Battery Connection
For the connection of "ST 21solar-battery" to "ST 04 chargecontroller"
ST 10Electric Meter
Single-phase electronic ACmeterfor measuring of the generatedsolar energy.Display of current power, kWh,measurement duration, inputtingof tariff possible.Available versions:230 V / 50 Hz230 V / 60 Hz115 V / 60 Hz
ST 11Input /Supply Meter
Single-phase electronic ACmeters for measuring of thesolar energy fed into the gridand for measuring of theenergy drawn from the grid.Display same as ST 10Available versions:230 V / 50 Hz230 V / 60 Hz115 V / 60 Hz
ST 08DC Load Connection
For connection to "ST 04solar charge controller" andoperation of direct currentloads 12 V / max. 8 A
ST 12Automatic Insulation Unit
For monitoring single-phasepower feeding systems. Itprevents uncontrolled islandeffects following failure orshutdown of the publicelectricity supply.Operating voltage 230 V / 50 Hz
ST 14Module Stand
For the illumination of a10 W solar module bymeans of a 400 Wdimmable halogen spotlight.The inclination of the solarmodule and the height anddistance of the spotlight tothe solar module areAdjustable.The inclination of thespotlight can also be alteredby fine adjustment.The solar module can beswung to simulate thesun's path during the day.Power supply 230 V / 50-60Hz.
Photovoltaik
IKS
Profi
ST 16Diode Series Connection
To perform the basicexperiments "Characteristiccurve of a diode" and"Characteristic curve ofa diode series connection”.Power supply external24 V DC by "ST 27 PowerSupply".
ST 17Shunt
For measuring current upto 1.5 A as voltage drop atthe shunt resistance.E.g. for measurements ingrid parallel operationcircuits using anoscilloscope.
ST 19Set of Safety Test Leadswith movable laboratory stand
Highly flexible safety-test leadswith 4 mm plugs. Contactsgold-plated brass/hard copper,inclusive movable laboratorystand with 2 brackets suppliedwith total 42 holding fingers.Lockable wheels, height 1.45 m
ST 18Set of Safety Test Leads
Highly flexible safety-test leadswith 4 mm plugs. Contactsgold-plated brass/hard copper,inclusive wall bracket with21 holding fingers.
ST 20 ACAC Load
Panel 160 W bulbStandard plug socketwith switch.Available versions:230 V / 50-60 Hz115 V / 60 Hz
ST 15Solar ModuleConnection Outdoor
For connection of themodule "ST 22 SolarModule Outdoor " orsimilar to the socket onthe front. The solarmodule is connecteto the two front socketsof the schematicallyshown solar module.
ST 20 ACAC Load
Panel 260 W bulb.Standard plug socketwith switch.Available versions:230 V / 50-60 Hz115 V / 60 Hz
ST 20 ACAC Load
Panel 39 W Energy-saving lamp.Standard plug socketwith switch.Available versions:230 V / 50-60 Hz115 V / 60 Hz (15 W)
Photovoltaik
IKS
Profi
ST 21Solar Battery
Closed lead-gel batteryespecially for storing solarenergy. Connected via"ST 09 battery connection"to "ST 04 solar chargecontroller" for operation ofan island grid with storage.12 V / 27 Ah C100.
ST 22Solar Module Outdoor
Solar module for outdoorexperiments. Angle ofinclination adjustable,can be read off on a large
degree scalePower 55 Wp
Operation with “ST 15Solar module connection
outdoor”.
ST 24Set Multimeter
Particularly robust.Automatic range selection,large display.DC / AC max. 1000 V,max. 10 A
ST 27Power Supply
For the power supply of"ST 16 diode series connection”Control range 0 - 30 V DC/ 0-2 APower supply:115-230 V / 50-60 Hz.
ST 23DC Meter
Electronic DC meter formeasuring direct current loads.Using in load cricuits.Display of current power andWh, reset button.
ST 28 Solar Module polycrystallineST 28 Solar Module amorphous
Alternatively addidionalsolar module for"ST 14 moduleFrame". Quickchange holder.Power:Polycrystalline ca. 10 WAmorphous ca. 5 W
ST 30Fuse Box
Fuse box with 4-pole FI-circuit breaker, CEE plugand 1.5 m feed cable withCEE plug.400 V / 50 Hz.
ST 20 DCDC Load
Panel 450 W halogen lamp,with switch, 12 V.
ST 20 RWSet of electrical loads
Four variable resistors:15 Ohm / 5,5A170 Ohm / 1,7A325 Ohm / 1,2A15,8 K.Ohm / 0.17A
Photovoltaik
IKS
Profi
ST 97Basic PhotovoltaicLaboratory
Detailed experimentalinstructions on 12 themes,with solutions. Available inGermanEnglishSpanishFrench
ST 98Instruction Manual
Instructions for allcomponents.Available inGermanEnglishSpanishFrench
Technical changes reserved 2014-06
Reseller
IKS Photovoltaik GmbH
Tel. +49 561 / 9538050Fax + 49 561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
ST 95Transformer
For the adaption of ST 02and ST 14 in 115 V-gridss. Inclusive outlet strip230 VTransormer 115 V AC to230 VAC / 500 W
ST 96Laboratory Table
Laboratory table , lockable wheels.Serves as a support for "ST 99 take-upframe", incl. fastening screws.Tabletop 1.25 x 0.62 m, height 0.74 m
ST 99 10 panelsHolding Frame
Take-up frame for 10instruction panels.
ST 99 15 panelsHolding Frame
Take-up frame for 15instruction panels.
IKS
Technikerschule Butzbach„Solartrainer Profi has been in use for 15 years completely error-free and without repairs”
Profi
Handwerkskammer Münster
„
Already the prototype won over -Solartrainer Profi in successful operation since 1997”
Landesstelle Hessen für gewerbliche
Berufsförderung in Entwicklungsländern„Solartrainer Prof for multiplier training”
Bildungsinstitut Pscherer“Fit for the job: basic and continuing vocational
training with the Solartrainer Profi”
BZ Bildungszentrum Kassel„Since 1997 more than 500 participants were trained with the Solartrainer Profi”“
University of NairobiInstitute of Nuclear Science and Technology
Some user report on practical experiences:
Photovoltaik
IKS
One device - double benefit: Innovative PV measurement equipment foruse at the training system and at real PV plants
PV vocational education and training
Double benefit
The particular feature: The newly into the PVtraining system integrated Photovol ta icmeasurement equipment can be used afterwardsfor measurments and tests at real photovoltaicinstallations.Asystem with double benefit. Becauseas always before we have focused on a highpract ical relevance when select ing thecomponents.
However, this also means that this subject has to bean integral part of the vocational education andtraining in the field of photovoltaic. A development,that was taken up with our latest product innovation.The well-known PV training system SolartrainerProfi was expanded with a measurementequipment, consisting of an innovative multifunctioninstrument, remote datalogger with radiotransmission, transducer clamps and an ISETSensor irradiation sensor with dimmable halogenspot for setting of irradiation values, as well aspractice-oriented didactic materials.
The PV training system Solartrainer Profi forvocational education and training wasexpanded with an innovative Photovoltaicmeasurement equipment
The background: Today PV plants are working veryreliable. Nevertheless they often generate only apart of the maximum possible power. The causesare multible and it is not rare that they can be tracedback before the period of the actual installation.Because even on the way to the installation sitemicro cracks can arise because of incorrect storageor as a result of incautious transport. The microcracks cannot be seen with the naked eye, howeverthe consequences have far reaching implications:If water has penetrated or soldered bonds wereinterrupted the efficiency of solar modules can benoticeable reduced. The financial losses for privateoperators as well as investors in large solar systemsmay be substancial. In practice the possibility ofmonitoring the characteristic curves of single solarmodules, strings and the test of completephotovoltaic installations becomes more and moreimportant.
ProfiPhotovoltaik
IKS
new
Profi
IKSPhotovoltaik
ProfiPhotovoltaik
IKS
Scope of delivery
n Multifunction instrument with tool pocket
Measuring range performance analysis:Voltage DC: 15,0 V - 999,9 VVoltage AC: 50,0 V - 265,0 VCurrent DC (über Stromzange): 50 mA - 1100 ACurrent AC (über Stromzange): 10 mA - 1200 APower DC: 1 W - 999,9 kWPower AC: 1 W - 999,9 kW
Measuring range I-U curve measurement:Voltage DC: 5,0 V - 999,9 VCurrent DC: 0,1 A - 10,0 APower DC: 50 W - 999,9 W / 1.000 kW - 9.999 kWIrradiance (with ST 36) 1,0 mV - 100,0 mV
PV measurement equipment
IKS Photovoltaik GmbH
Tel. 0561 / 9538050Fax 0561 / 9538051
Training systems
Measurement engineering
Special developments
An der Kurhessenhalle 16 b34134 Kassel / Germany IKS
Photovoltaik
Experiments
n
n
n
n
n
n
n
n
n
I-U curve recording of different solar modules
I-U curve recording of different solar modulesat different irridiation intensities
Temperature influence on the I-U curve ofdifferent solar modules
I-U curve recording of a series connection ofsolar modules
I-U curve recording of a parallel connection ofsolar modules
Shading of a series connection of solar moduleswithout bypass diode, I-U curve recording
Shading of a series connection of solar moduleswith bypass diode, I-U curve recording
Photovoltaic plant mains parallel operation,measuring of the inverter efficiency
Test of a photovoltaic plant mains parallel operation,measuring also the irradiation and temperature.Measuring of the inverter efficiency, solar modulesefficiency and the overall efficiency (performanceratio) and issue of a test report
n
n
n
n
n
n
n
Test of a photovoltaic plant mains parallel operation.Simulation of system failures:PV power too low / irradiation sensor failure /Irradiation value too low for evaluation
I-U curve recording and evaluation of a solar module(solar module simulated) also measuring the irradiationand temperature.Detection of underperformance
I-U curve recording and evaluation of a string(solar module simulated) also measuring the irradiationand temperature.Detection of underperformance
I-U curve recording and evaluation of a solar module(solar module outdoor) also measuring the irradiationand temperature and considering the position of the sun.Detection of underperformance
Rapid test on solar modules and strings with and withoutmeasuring the irradiation and temperature
Measuring the internal resistance of a solar module
Reading out and processing of the data with a PC
n
n
n
n
n
n
n
n
Remote datalogger with radiotranmission for irradianceand temperatureTransd. clamp DC 10 A /100 ATransd. clamp AC 5 A / 100 ATraining panelST 36 Solar radiation sensor(sensor removable)Module temperature sensorand ambient temperaturesensor -20 bis 100 °CMeasuring cables and adapter plugsData transfer sofware and evaluation softwareExperimental instructions
Subject to technical modifications. Stand: June 2014