Klip-Lok 700-2014:Klip-Lok 700-NEW 30/6/14 20:13 Page 1

Page 2: Klip-Lok 700-2014:Klip-Lok 700-NEW 30/6/14 20:13 Page 1 · PDF file · 2017-11-23Talk to us, THE SMART ROOF PEOPLE Visit or email info@ Global Roofing Solutions Klip-Lok 700™ 700

The Profile

Is roll-formed from certified steel complyingwith (select from steel column in abovetable). The profile shall have 4 trapezoidelribs at 233 mm centres giving a net cover of700 mm. The male rib shall have spurs toensure a positive double interlocking action atside-laps. Each pan shall incorporate twostiffener ribs.

Assembly

It is recommended that Klip-lok 700™

sheeting be laid by an approved contractor instrict accordance with manufacturersspecifications. When using a GrS(Brownbuilt) Approved Contractor, a five yearguarantee on site-workmanship and water-tightness may be issued after approval byGlobal roofing Solutions (Pty) ltd.

Flashing

Stop endings must be formed at the apexand the pan turned down at the eaves toform a drip. The roof sheeting shall be closedas necessary with purpose made flashingsof a design approved by the supplier. Theseflashings shall be notched around ribs wherenecessary and fixed on S10 clips. All theseoperations must be performed with specialtools available from the supplier.

Site handling

All Klip-lok 700™ materials should besuitably supported under cover until requiredto be hoisted into final position.

Cleaning up

The completed roofing, including gutters,must be handed over free of any swarf andother debris.

Quality assurance

The manufacturer shall be assessed andcertified as complying with ISo 9001:2008Quality Management System.

Translucent Sheeting

The Klip-lok 700™ profile is available inPolycarbonate and Fibreglass (GrP).

Materials

The roofing shall be Klip-lok 700™ profile, roll-formed in continuous lengths and can be lightindustrial / heavy industrial in (select from table below). Klip-lok 700™ is obtained fromGlobal roofing Solutions (Pty) ltd.

Material Steel Colour one Side Colour Two Side

Galvanised Z275ISQ 550

––––––– –––––––

Chromadek® Z200 Special

Zincalume® AZ150G550

––––––– –––––––

Clean ColorBoND™ AZ150 Special

ZincAl® AZ150G550

––––––– –––––––

ColorPlUS® AZ150 Special

700

Typical specification

Page 3: Klip-Lok 700-2014:Klip-Lok 700-NEW 30/6/14 20:13 Page 1 · PDF file · 2017-11-23Talk to us, THE SMART ROOF PEOPLE Visit or email info@ Global Roofing Solutions Klip-Lok 700™ 700

Where insulation is installed between purlin and sheeting, the length ofscrews should be increased depending on the compressed thickness anddensity of the insulation.For Steel Purlins – At least 3 threads should protrude past the support.For Timber Purlins – The screw should penetrate the purlin by the samedepth recommended as if there was no insulation.

*For light steel frame purlins less than 1mm thick, please contact GRS.

Fasteners

The recommended fasteners for fixing the Kl 700clips to steel or timber purlins are as follows:

Steel Purlins 1mm to 4,5mm thickNo.10-16 x 16mm long self drilling Wafer headPH2 screws #3 drill point.

Steel Purlins 6mm to 12,5mm thickNo.12-24 x 38mm long self drilling Wafer headPH3 screws #5 drill point.

Timber PurlinsNo.10-11 x 45mm long self drilling Wafer headPH2 screws, type 17 drill point.

Note

Fasteners must be selected to match the life expectancy of the roofingand cladding material. Class 3 fasteners, complying with SANS 1273,should be used in conjunction with all roofing and cladding material.

The concealed fixing concept

Note

Where screws exceed 45mm long, theyshould be No.12 with a PH3 head.

Page 4: Klip-Lok 700-2014:Klip-Lok 700-NEW 30/6/14 20:13 Page 1 · PDF file · 2017-11-23Talk to us, THE SMART ROOF PEOPLE Visit or email info@ Global Roofing Solutions Klip-Lok 700™ 700

Klip-lok 700™ in addition offers a fascia gutterand fascia capping, with horizontal stiffening ribsrolled in, giving a clean unbroken surface.

Used both as gutter and barge capping, thefascia gutter permits clean lined eaves for anattractive finish.

With the gutterattached bymeans of theappropriateconcealed bracketand verandahbolts to thesheeting troughand the concealedsupport bracketpop rivetted to thenarrow flute of thesheeting at 1165 mm centres.

Sheet lengths

Klip-lok 700™ is available ex-factory in sheetlengths limited only by transport restrictions,normal loads 12.5 m and abnormal loads18.6 m. longer lengths can be milled on site,eliminating end laps which are notrecommended.

End lapping negates the concealed fixconcept and no water tightness guaranteecan be given.

End lapping reduces the life expectancy ofthe roof, due to corrosion.

Bullnosing and cranking

Rib cap detail

Springing

Klip-lok can be sprung to a minimum radiusof 36m (convex only).

Gutters and fascias

Note

Consideration for road transport has tobe taken into account.

refer to GrS Installation manual fordetailed dimensions and fixinginstructions.

Site cranking for milled sheets isavailable on application.

Note

reverse cranking is not possible.

Note: For polystyrene place sheet metal bearingstrip of 150mm x 0.8mm thick over insulationbefore fixing clips.

Please contact GrS for insulation specificfixing details.

Additional applications

Page 5: Klip-Lok 700-2014:Klip-Lok 700-NEW 30/6/14 20:13 Page 1 · PDF file · 2017-11-23Talk to us, THE SMART ROOF PEOPLE Visit or email info@ Global Roofing Solutions Klip-Lok 700™ 700

Load span table

The recommended purlin support centres are based onthe following design criteria and obtained through testing:

TYPE OF SPAN

Drainage table

Maximum roof run (in metres) for roof slopes and rainfallintensities shown. These figures are based on unrestricted, freeflow of water.

1.50 kN/m2 1.60 kN/m2

0.75 kN/m2

ROOFS

WALLS

Ultimate SuperimposedDistributed Load

UltimateUplift Load

1 in 50 (1˚)1 in 30 (2˚)1 in 20 (3˚)1 in 12 (5˚)1 in 7.5 (7.5˚)1 in 6 (10˚)

648094

53667895

405058708391

324046566673

Rainfall Intensity mm/h

300 400 500250Roof Slope

RoofsSingle SpanEnd SpanInternal SpanCantilever (Unstiffened)Cantilever (Stiffened -max sheet length of 13m)

Normal mass kg/m2

0.5 mmISQ550 (3T)

0.58 mmISQ550 (3T)

0.47 mmG550

0.5 mmG550

0.53 mmG550

GALVANISED / CHROMADEK® ZINCALUME® / COLORBOND™

0.55 mmG550

ZINCAL® / COLORPLUS®

MAXIMUM ALLOWABLE SUPPORT SPACINGS

Profile : Klip-Lok 700™

1.400 m1.700 m2.000 m0.180 m0.400 m

5.5

1.300 m1.600 m1.900 m0.150 m0.350 m

5.1

1.800 m2.100 m2.500 m0.260 m0.600 m

6.6

1.400 m1.700 m2.000 m0.150 m0.350 m

5.2

1.800 m2.100 m2.500 m0.180 m0.400 m

5.75

1.500 m1.900 m2.300 m0.180 m0.400 m

5.7

Purlin support centres are based on the following design criteria and obtained through testing: roofs – ultimate super-imposeddistributed load of 1.50 kN/m2 and ultimate uplift load of 1.6 kN/m2.

Page 6: Klip-Lok 700-2014:Klip-Lok 700-NEW 30/6/14 20:13 Page 1 · PDF file · 2017-11-23Talk to us, THE SMART ROOF PEOPLE Visit or email info@ Global Roofing Solutions Klip-Lok 700™ 700

* When sheet lengths are over 30m flashings mustbe fixed to sheets using sliding brackets.

Available in 0.58 mm / 0.8 mm thick commercial qualitygalvanised Z275 steel, 0.53 mm thick Zincalume® AZ150 or0.55 mm thick ZincAl® AZ150. or with a colour option

Chromadek® (Galvanised Z200), Clean ColorBoND™

(Zincalume® AZ150) or ColorPlUS® (ZincAl® AZ150) finishto one / two sides.

GRS

Klip-

Lok

700

06/1

5

Tools

Please visit our website or contact GrS for standard flashing details

Popular flashings

[email protected]

Boksburg Tel: (011) 898 2900 Fax: (011) 892 1455Cape Town Tel: (021) 521 1900 Fax: (021) 556 6936 Durban Tel: (031) 538 0940/1/2 Fax: (031) 502 3764 East london Tel: (043) 731 1895/98 Fax: (043) 731 1926 Bloemfontein Tel: (051) 432 3724/6 Fax: (051) 432 3723rustenburg Tel: (014) 596 6121 Fax: 086 644 8344

Zambia Tel: +260967495541Botswana Tel: +267 3105761 Fax: +267 3105762Namibia Tel: +264(0)61 263890 Fax: +264(0)61 263890Zimbabwe Tel: +263 4 774 699GrS Exports Tel: (011) 898 2900 Fax: (011) 892 1455 Helm Engineering Tel: (011) 876 1300 Fax: (011) 876 1304