key plan - not to be moved -...

4
RICHARDS ST SEYMOUR ST C A2.03 B A2.02 E A2.05 289' VIEW CONE 9.1 H A2.08 RETAIL ENTRY RETAIL ENTRY OFFICE ENTRY OFFICE ENTRY 3950 88.05m 107.80m 103.85m 99.90m 95.95m 92.00m 84.10m 80.15m 76.20m 72.25m 68.30m 64.35m 60.40m 56.45m 52.50m 48.55m 44.60m 32.50m 111.30m TYP. TYP. MECH 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 1 3500 12100 3950 3950 107.80m 103.85m 111.75m TYP. 21 20 19 120.08m ROOF 3950 8330 119.30m 13 AUG 2010 CONSULTANT DRAWING TITLE JOB TITLE DATE DRAWN SCALE CHECKED JOB NO. Architects Urban Designers HENRIQUEZ ï PARTNERS 402 West Pender Street Vancouver, BC V6B 1T6 Tel: 604.687.5681 Fax: 604.687.8530 1007 GH NJ TELUS GARDEN ISSUED FOR REZONING APPLICATION 21 FEB 2011 ISSUED TO C.O.V. (PRELIMINARY) 22 DEC 2010 NORTH ELEVATION GEORGIA STREET A3.01 1:600 NORTH ELEVATION SCALE: 1:600 1 GEORGIA ST ROBSON ST RICHARDS ST SEYMOUR ST LANE KEY PLAN 1 1 11 2 6 12 9 9 7 2 5 1 9 M A T E R I A L L E G E N D 1. ARCHITECTURAL CONCRETE 2. FRAMELESS CURTAIN WALL GLAZING W/ CLEAR SPANDREL PANELS 3. FRAMELESS CURTAIN WALL GLAZING W/ FRIT, VERTICAL GLASS FINS + INTEGRATED LED 4. WOOD PANELS 5. GLULAM BEAMS 6. GLASS PANEL GUARDRAILS 7. STEEL STRUCTURE 8. STONE CLADDING 9. CLEAR STRUCTURAL GLAZING 10. WINDOW WALL GLAZING 11. ALUMINUM GRILLE 12. CURTAIN WALL W/ LOUVER SPANDREL 11 9 8 7 7 8 7

Upload: vuongnguyet

Post on 29-Apr-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: KEY PLAN - NOT TO BE MOVED - rezoning.vancouver.carezoning.vancouver.ca/applications/555robson/documents/elevations.pdf · frameless curtain wall glazing w/ clear spandrel panels

NORTH ELEVATIONGEORGIA STREET ELEVATION

RICHARDSST

SEYMOURST

CA2.03

BA2.02

EA2.05

289'

VIEW CONE 9.1

HA2.08

RETAILENTRY

RETAILENTRY

OFFICEENTRY

OFFICEENTRY

3950

88.05m

107.80m

103.85m

99.90m

95.95m

92.00m

84.10m

80.15m

76.20m

72.25m

68.30m

64.35m

60.40m

56.45m

52.50m

48.55m

44.60m

32.50m

111.30m

TYP.

TYP.

MECH

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

1

3500

1210

039

50

3950

107.80m

103.85m

111.75m

TYP.

21

20

19

120.08mROOF

3950

8330

119.30m

13 AUG 2010

CONSULTANT

DRAWING TITLE

JOB TITLE

DATE DRAWN

SCALE CHECKED

JOB NO.

Architects Urban Designers

HENRIQUEZ ï PARTNERS

402 West Pender StreetVancouver, BC V6B 1T6

Tel: 604.687.5681Fax: 604.687.8530

1007

GH

NJ

TELUS GARDEN

ISSUED FOR REZONING APPLICATION 21 FEB 2011

ISSUED TO C.O.V. (PRELIMINARY) 22 DEC 2010

NORTH ELEVATIONGEORGIA STREET

A3.01

1:600

NORTH ELEVATIONSCALE: 1:600

1

GE

OR

GIA

ST

RO

BS

ON

ST

RICHARDS ST

SEYMOUR ST

LANE

KEY PLAN - NOT TO BE MOVED

KEY PLAN

1

1

11

2

6

12

9

9

7

2

5

19

M A T E R I A L L E G E N D

1. ARCHITECTURAL CONCRETE 2. FRAMELESS CURTAIN WALL GLAZING

W/ CLEAR SPANDREL PANELS 3. FRAMELESS CURTAIN WALL GLAZING W/ FRIT,

VERTICAL GLASS FINS + INTEGRATED LED 4. WOOD PANELS 5. GLULAM BEAMS 6. GLASS PANEL GUARDRAILS 7. STEEL STRUCTURE 8. STONE CLADDING 9. CLEAR STRUCTURAL GLAZING10. WINDOW WALL GLAZING11. ALUMINUM GRILLE12. CURTAIN WALL W/ LOUVER SPANDREL

11

9

8

7

7

8

7

Page 2: KEY PLAN - NOT TO BE MOVED - rezoning.vancouver.carezoning.vancouver.ca/applications/555robson/documents/elevations.pdf · frameless curtain wall glazing w/ clear spandrel panels

GEORGIAST

ROBSONST

AA2.01

FA2.06

GA2.07

DA2.04

A'A2.01

FUTURERETAIL ENTRY

FUTURERETAIL ENTRY FUTURE

RETAIL ENTRYEXISTING

TELUS ENTRY

28.23m

35.73m

39.85m

44.85m

49.35m

53.98m

58.10m

62.20m

67.55m

72.35m

30.68m

3950

3660

44.60m

32.70m

4

1

41.20m MECH

37.54m 2

4840

48.55m 5

TYP.

3400

52.50m 6

56.45m 7

60.40m TERRACE

3950

TYP.

B.G. 28.540

B.G. 28.790

B.G. 29.250B.G

. 30.0

30B.G. 30.590B.G

. 31.0

20B.G. 31.460

B.G. 31.730

B.G. 31.970

B.G. 32.630

B.G. 32.680

B.G. 32.320

B.G. 32.790

RETAILENTRY

RETAILENTRY

FUTURE DATA CENTER ADDITION

EXISTING TELUS FACILITY

86.99m

83.39m

79.79m

76.19m

72.59m

68.99m

90.59m

65.09m9

10

11

12

13

14

15

13 AUG 2010

CONSULTANT

DRAWING TITLE

JOB TITLE

DATE DRAWN

SCALE CHECKED

JOB NO.

Architects Urban Designers

HENRIQUEZ ï PARTNERS

402 West Pender StreetVancouver, BC V6B 1T6

Tel: 604.687.5681Fax: 604.687.8530

1007

GH

NJ

TELUS GARDEN

ISSUED FOR REZONING APPLICATION 21 FEB 2011

ISSUED TO C.O.V. (PRELIMINARY) 22 DEC 2010

WEST ELEVATIONSEYMOUR STREET

A3.02

1:600

WEST ELEVATIONSCALE: 1:600

1

GE

OR

GIA

ST

RO

BS

ON

ST

RICHARDS ST

SEYMOUR ST

LANE

KEY PLAN - NOT TO BE MOVED

KEY PLAN

1 1

6

2

85

M A T E R I A L L E G E N D

1. ARCHITECTURAL CONCRETE 2. FRAMELESS CURTAIN WALL GLAZING

W/ CLEAR SPANDREL PANELS 3. FRAMELESS CURTAIN WALL GLAZING W/ FRIT,

VERTICAL GLASS FINS + INTEGRATED LED 4. WOOD PANELS 5. GLULAM BEAMS 6. GLASS PANEL GUARDRAILS 7. STEEL STRUCTURE 8. STONE CLADDING 9. CLEAR STRUCTURAL GLAZING10. WINDOW WALL GLAZING11. ALUMINUM GRILLE12. CURTAIN WALL W/ LOUVER SPANDREL

7

11

E D C B A

Page 3: KEY PLAN - NOT TO BE MOVED - rezoning.vancouver.carezoning.vancouver.ca/applications/555robson/documents/elevations.pdf · frameless curtain wall glazing w/ clear spandrel panels

GEORGIASTROBSON

STPROPOSED

LANE

AA2.01

FA2.06

GA2.07

EXISTINGHOTEL

B.G. 32.110

B.G. 31.960

B.G. 31.530

B.G. 30.780B.G

. 30.0

00B.G. 29.220B.G

. 28.4

80B.G. 28.110

B.G. 27.700

B.G. 26.970

B.G. 26.670

B.G. 26.500

88.05m

107.80m

103.85m

99.90m

95.95m

92.00m

84.10m

80.15m

76.20m

72.25m

68.30m

64.35m

60.40m

56.45m

52.50m

48.55m

44.60m

32.50m

111.30m

3950

1210

0

TYP.

TYP.

MECH

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

1

3500

3950

107.80m

103.85m

111.75m

TYP.

21

20

19

120.08m ROOF

3950

3950

8330

A'A2.01

OFFICEENTRY

RETAILENTRY

PARKINGPARKING

289'

VIEW CONE 9.1

119.30m

27.82m

VIEW CONEORIGIN

404'-3"151.04m

D'A2.04

DA2.04

SCOTIA TOWER VIEWCONE SHADOW

442'162.54m

39.00m

32.05m

26.90m

3

2

1

35.10m M

42

43

ROOF

44

45

44.75m

47.39m 5

4

41

11

10

9

8

7

6

38

39

40

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

151.85m

154.65m

158.41m

162.47m

52.67m

55.31m

57.95m

60.59m

63.23m

65.87m

68.51m

71.15m

73.79m

76.43m

79.07m

81.71m

84.90m

87.54m

90.18m

92.82m

95.46m

98.26m

101.06m

103.86m

106.66m

109.46m

112.26m

115.06m

117.86m

120.66m

123.85m

126.65m

129.45m

132.25m

135.05m

137.85m

140.65m

143.45m

146.25m

149.05m

50.03m

VIEW CONE 9.2.1

BUIL

DIN

G L

INE

13 AUG 2010

CONSULTANT

DRAWING TITLE

JOB TITLE

DATE DRAWN

SCALE CHECKED

JOB NO.

Architects Urban Designers

HENRIQUEZ ï PARTNERS

402 West Pender StreetVancouver, BC V6B 1T6

Tel: 604.687.5681Fax: 604.687.8530

1007

GH

NJ

TELUS GARDEN

ISSUED FOR REZONING APPLICATION 21 FEB 2011

ISSUED TO C.O.V. (PRELIMINARY) 22 DEC 2010

EAST ELEVATIONRICHARDS STREET

A3.03

1:600

EAST ELEVATIONSCALE: 1:600

1

GE

OR

GIA

ST

RO

BS

ON

ST

RICHARDS ST

SEYMOUR ST

LANE

KEY PLAN - NOT TO BE MOVED

KEY PLAN

11

7

6

8

8

5

2

3

7

9

7

M A T E R I A L L E G E N D

1. ARCHITECTURAL CONCRETE 2. FRAMELESS CURTAIN WALL GLAZING

W/ CLEAR SPANDREL PANELS 3. FRAMELESS CURTAIN WALL GLAZING W/ FRIT,

VERTICAL GLASS FINS + INTEGRATED LED 4. WOOD PANELS 5. GLULAM BEAMS 6. GLASS PANEL GUARDRAILS 7. STEEL STRUCTURE 8. STONE CLADDING 9. CLEAR STRUCTURAL GLAZING10. WINDOW WALL GLAZING11. ALUMINUM GRILLE12. CURTAIN WALL W/ LOUVER SPANDREL

1

10

9

7

7

7

6

2

9

62

1

79

7

7

Page 4: KEY PLAN - NOT TO BE MOVED - rezoning.vancouver.carezoning.vancouver.ca/applications/555robson/documents/elevations.pdf · frameless curtain wall glazing w/ clear spandrel panels

SEYMOURST

RICHARDSST

EXIST.LANE

CA2.03

28.23m

35.73m

39.85m

44.85m

49.35m

53.98m

58.10m

62.20m

67.55m

72.35m

HA2.08

RETAIL ENTRY

EXISTINGTELUS ENTRY

RETAIL ENTRY RESIDENTIAL

ENTRYRETAIL ENTRY

27.82m

VIEW CONEORIGIN

27.25m

404'-3"

SCOTIA TOWER VIEWCONE SHADOW

151.04m

442'162.54m

VIEW CONE 9.2.1

39.00m

32.05m

26.90m

3

2

1

35.10mM

42

43

ROOF

44

45

44.75m

47.39m5

4

41

11

10

9

8

7

6

38

39

40

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

151.85m

154.65m

158.41m

162.47m

52.67m

55.31m

57.95m

60.59m

63.23m

65.87m

68.51m

71.15m

73.79m

76.43m

79.07m

81.71m

84.90m

87.54m

90.18m

92.82m

95.46m

98.26m

101.06m

103.86m

106.66m

109.46m

112.26m

115.06m

117.86m

120.66m

123.85m

126.65m

129.45m

132.25m

135.05m

137.85m

140.65m

143.45m

146.25m

149.05m

50.03m

BA2.02

EA2.05

13 AUG 2010

CONSULTANT

DRAWING TITLE

JOB TITLE

DATE DRAWN

SCALE CHECKED

JOB NO.

Architects Urban Designers

HENRIQUEZ ï PARTNERS

402 West Pender StreetVancouver, BC V6B 1T6

Tel: 604.687.5681Fax: 604.687.8530

1007

GH

NJ

TELUS GARDEN

ISSUED FOR REZONING APPLICATION 21 FEB 2011

ISSUED TO C.O.V. (PRELIMINARY) 22 DEC 2010

A3.04

1:600

SOUTH ELEVATIONSCALE: 1:600

1

SOUTH ELEVATIONROBSON STREET

A

GE

OR

GIA

ST

RO

BS

ON

ST

RICHARDS ST

SEYMOUR ST

LANE

KEY PLAN - NOT TO BE MOVED

KEY PLAN

1

1

7

3

1

6

M A T E R I A L L E G E N D

1. ARCHITECTURAL CONCRETE 2. FRAMELESS CURTAIN WALL GLAZING

W/ CLEAR SPANDREL PANELS 3. FRAMELESS CURTAIN WALL GLAZING W/ FRIT,

VERTICAL GLASS FINS + INTEGRATED LED 4. WOOD PANELS 5. GLULAM BEAMS 6. GLASS PANEL GUARDRAILS 7. STEEL STRUCTURE 8. STONE CLADDING 9. CLEAR STRUCTURAL GLAZING10. WINDOW WALL GLAZING11. ALUMINUM GRILLE12. CURTAIN WALL W/ LOUVER SPANDREL

69

10

6

10

4

7

2

7