joseph e. bavaria, m.d. roberts-measy professor …...surgery must integrate anatomy with the...

63
Joseph E. Bavaria, M.D. Roberts-Measy Professor and Vice Chief CardioVascular Surgery Director: Thoracic Aortic Surgery Program University of Pennsylvania, USA Rocky Valve Montana 2019

Upload: others

Post on 24-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Joseph E. Bavaria, M.D.Roberts-Measy Professor and Vice Chief

CardioVascular SurgeryDirector: Thoracic Aortic Surgery Program

University of Pennsylvania, USA

Rocky Valve Montana 2019

Page 2: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 3: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Clinical BAV Syndrome ……

(“Houston, We have a Problem!”)

1. 37 yr old Female, ICU Nurse,

2. BAV syndrome, 5 cm Ascending Aorta, Mild STJ effacement, 4.5 cm Sinus segment diameter

3. Trace to Mild AI, No AS, No gradient ……. A ‘Physiologically” Near-Normal Aortic Valve; Normal LV, No CHF, No symptoms!

Apollo 13

Bicuspid Valve and the Aorta: Effect of New guidelines?

Page 4: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Problem in the World

Wide Cardiac Surgery

Community …… Are we

Ready for “Prime Time”

……. No!

Page 5: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Estimated Number of Ascending Aorta(s) >

4.5 cm in USA!!

1 Million!

> 4.0 cm ….. 3 million (??)

Hal Dietz, MD (Johns Hopkins)

Page 6: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 7: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 8: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Cook AC et al. Surgical anatomy of the heart. In: Selke FW, del Nido PJ, Swanson SJ, eds.,

Sabiston & Spencer Surgery of the Chest (8ed). Philadelphia: Elsevier Saunders;2010. p.

702.

Page 9: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

David TE. Aortic valve-sparing operations. In: Selke FW and Ruel M, eds., Atlas

of Cardiac Surgical Techniques (1ed). Philadelphia: Elsevier Saunders;2010. p.

151.

Page 10: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Cook AC et al. Surgical anatomy of the heart. In: Selke FW, del Nido PJ, Swanson SJ, eds.,

Sabiston & Spencer Surgery of the Chest (8ed). Philadelphia: Elsevier Saunders;2010. p.

704.

Page 11: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

de Kerchove L and El Khoury G. Ann Cardiothorac Surg 2013;2(1):57-64.

Page 12: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Khelil N et al. Ann Thorac Surg 2015;99:1220-7.

Page 13: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 14: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Lansac E et al. Ann Cardiothorac Surg 2012;2(1):117-23.

Page 15: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Jeanmart H et al. Ann Thorac Surg 2007;83:S746-51.

Page 16: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Cusp mobility = Free margin length

Length of cusp insertion

Key Concept: The more you reduce the free margin, the less mobility

the cusp retains

Page 17: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Holubec T et al. Cor et Vasa 2013;55:e479-86.

Schäfers H-J et al. J Thorac Cardiovasc Surg 2006;132:436-8.

Page 18: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Marom G et al. J Thorac Cardiovasc Surg 2013;146:1227-31.

Average coaptation height decreases with an increase in the STJ/AA ratio

Page 19: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

A decrease in AA diameter increases coaptation height and area

Marom G et al. J Thorac Cardiovasc Surg 2013;145:406-11.

Page 20: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Comparison of Post-Repair Coaptation Height: From 3D TEE and Gaussian Curves• Valve repair with simple sub-

annular reduction (SCA) • David V + Valve repair

Annular Plane Annular Plane

David V/BAV repair depicts superior achievement of coaptation line elevation above

the basal annular plane

Average coaptation height: 2.9 mm Average coaptation height: 6.0 mm

Billowing Leaflet

Page 21: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Goal: Great Coaptation Zone with good symmetry, no “billowing”

Page 22: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

SCA BAV repair: mild billowing, asymmetric leaflet surface area

Series 8, image 137

Mild Billowing

Page 23: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 24: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Leonardo da Vinci’s Eddy Currents within the Sinuses of Valsalva

Morea M and De Paulis R. J Cardiovasc Med 2007;8:399-403.

Page 25: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Marfan’s Sinus of ValSalva

Aneurysm (7.0 cm.) with Severe

(+4) AI

Valve Sparing ?? Too much AI, too much aneurysmal dilation, too

much leaflet surface area,

Page 26: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

45 mm

Near Prophylactic Replacement

Page 27: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Anatomical root reconstruction (facts)

Individual sinus expansion Individual sinus expansion

Optimal anatomical

proportion

Optimal anatomical

proportion

Page 28: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Swanson & Clark. Circ Res 1974;35:871-82.

Tailored Graft; T. Gleason

Page 29: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Any patient with an aortic root aneurysm and normal aortic cusps.

Acute Type A Aortic dissection—difficult but durable.

Patients with root aneurysm and abnormal cusps that are repairable.

Bicuspid aortic valve—controversial.

Severe aortic insufficiency heightens the difficulty (esp. cusp pathology).

Page 30: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Modifications of a straight graft for a better root reconstruction

Uni-graftCardioroot

Valsalva graft

Page 31: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 32: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Sievers H-H and Schmidtke C. J Thorac Cardiovasc Surg 2007;133:1226-33.

Sievers Classification

Page 33: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Ryan LP et al. J Thorac Cardiovasc Surg 2014;147:1103-5.

Commissural Spacing in Tricuspid and Bicuspid Valves

Page 34: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 35: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Still frames to depict anatomy

NOTE; Pure AI, No Calcified Leaflets

Fairly large opening, no AS

Page 36: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Supra coronary

aneurysm

Page 37: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 38: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Most Common combination

BAV Ib/c + II usually associated with 15-25% larger annulus than standard for BSA

Page 39: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Ring

Ring

Bavaria Edited [BAV Typically either: Ib + II or Ic +II]

de Kerchove L, El Khoury G. Anatomy and pathophysiology of the ventriculo-aortic junction: implication in aortic valve repair surgery. Ann Cardiothorac Surg. 2013;2(1):57-64.

Page 40: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Bavaria Algorithm 06/01/2013 [Developed based on ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Surgical Management Guidelines]

Page 41: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 42: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Aortic Root Options

Page 43: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

“Florida Sleeve”

Ann Thor Surg 2009;87:11161-9

Page 44: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

David V Subtypes with Arch

Courtesy of Stanford CV Surgery

Page 45: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 46: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

ROBUST: Aortic Root

Reconstruction/Sinus of ValSalva Repair

Bavaria, Pochettino, Gleason, et al; Ann Thor

Surg 2003

Page 47: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Obliteration of Proximal False Lumen

Bavaria JE, et al; AATS 2001

Page 48: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Completed Root Repair and Aortic Valve

Resuspension with Neo-Media

Bavaria, Pochettino, Gleason, et al; Ann Thor Surg 2003

IMPORTANT: 72% of Aortic Roots/Valves

were NORMAL prior to Dissection!

Page 49: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 50: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 51: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

External ring annuloplasty

Lansac E et al. Eur J Cardiothorac Surg 2006;29:537-44

Page 52: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

External Stitch

Aicher D et al. J Thorac Cardiovasc Surg 2013;145:S30-4

Page 53: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual
Page 54: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

17 years after reimplantation

for acute dissection

4DMRI

Page 55: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Comparable root anatomy Post-Procedure

Remodeling Reimplantation

Page 56: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Modifications of the reimplantation technique for a better root reconstruction

Cochran - 1995 David V - 2003

Gleason – 2005 Hess – 2005

Lansac – 2005Stanford mod. 2004

Rama - 2007Takamoto - 2006

Page 57: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

JTCVS february 2019

Restoration of root and leaflet physiology

Page 58: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Courtesy of E. Lansac

Page 59: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

NORMAL INDIVIDUAL AFTER REIMPLANTATION WITH SINUSES

THE ANATOMICAL ROOT RECONSTRUCTION

Page 60: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Result after DV: Excellent Co-aptation

Page 61: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Tight Acute Interleaflet triangles

Courtesy of DePaulis and Lansac

Page 62: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Deep Knowledge of Root Anatomy makes a difference in Valve Sparing and Repair Surgery

Must Integrate Anatomy with the Physiology (Aneurysm and AI)

A Valve Sparing operation can be “Customized” for individual patient using “Ratio Anatomy”

There are many different kinds of Operations This is a “Set-up” forvthe rest of the

Morning!

Page 63: Joseph E. Bavaria, M.D. Roberts-Measy Professor …...Surgery Must Integrate Anatomy with the Physiology (Aneurysm and AI) A Valve Sparing operation can be “Customized” for individual

Questions?