JOB DESCRIPTIONSeries ULTI
Product Switch
Deliverable Installation Manual (MS18689)
Version 01
Release Date 22Noc2011
Created By Cecile
Approval By -
Size 105x105mm
Total Pages 24 page
Colour Black
Paper 80gsm or above woodfree paper
this page is infortmation only, not included manual
ULTI ZigBee Switch 105x105 r14.indd 1 11�11�22� ��2:50
This Installation Manual applies to the following products:
Product No. Description
U201SRY2KWZB 1 Gang 2000VA SwitchU202SRY2KWZB 2 Gang 2 x 1000VA Switch
ULTI ZigBee Switch 105x105 r14.indd 2 11�11�22� ��2:50
1ENGLISH
CONTENTS
IMPORTANT NOTES 2
WARNING 3
PACKAGE COMPONENTS 4
INTRODUCTION 5
OPERATING FUNCTION 6
INSTALLATION PROCEDURES 8
PROGRAMMING PROCEDURES 10
WIRING DIAGRAM 12
SPECIFICATION 13
ZIGBEE DEFINITIONS 14
LOAD TYPE TABLE(S) 15
TROUBLE SHOOTING GUIDE 18
ULTI ZigBee Switch 105x105 r14.indd 1 11�11�22� ��2:50
2
IMPORTANT NOTES HOW TO USE THIS MANUALThis manual explains how to install and operate your ULTI 1 Gang and 2 Gang Switches.
PRODUCT SAFETYThe ULTI unit complies with IEC60669-2-1 and operates at a RF frequency band of 2.4 GHz, ISM band standard. The effective radiated power of the Handheld Remote Controller Units does not exceed 1mW.
Additional hardware (like by-pass capacitor) is recommended to be used depending on the load type. Please read the load type table carefully to decide if your load type requires the use of this by-pass capacitor or not.
WARRANTYULTI products come with a one-year equipment-only warranty.
ULTI ZigBee Switch 105x105 r14.indd 2 11�11�22� ��2:50
3ENGLISH
WARNING
1. Miniature Circuit Breaker (MCB) MUST be switched off before changing loads. In switch off position, there is no isolation provided by the switch unit and line (AC) voltage will exist on the terminals and lamp socket even when the unit is in switch off mode.
2. Switch units cannot directly replace mechanical switches that are wired for 2 way (or more) circuit without modifying the wiring.
3. Installation of the switch unit behind large metal objects, such as refrigerators, cabinets or cupboards etc. will affect the wireless range and performance of switches.
4. Installation of the switch unit must be done in a plastic wall box. Using a metal wall box may dampen the radio signals, thereby reducing the efficacy of communication.
ULTI ZigBee Switch 105x105 r14.indd 3 11�11�22� ��2:50
4
PACKAGE COMPONENTS
OR
1 Gang Switch Module 2 Gang Switch Module
Installation Manual Capacitor x 1(1G)Capacitor x 2(2G)Screws
(M3.5 x 45) x 2(M3.5 x 26.5) x 2
(M4 x 25)* x 2
*only for China market
Control Unit(Cover Plates are to be purchased separetely)
Installation Manual
ULTI ZigBee Switch 105x105 r14.indd 4 11�11�22� ��2:50
5ENGLISH
INTRODUCTION
ULTI CONCEPTULTI, The Ultimate Switch, is a Schneider Electric Concept. It is a state-of-the-art lighting control and electrical automation scheme for residential, hotel and office use, offering sophisticated design, operational simplicity and flexibility to control electrical devices.
ULTI WIRELESS LIGHTING CONTROL SOLUTIONWith ULTI, you can use a Handheld Remote Controller Unit to control all functions, including pre-programming of multi-combination light groups and electrical home appliances for up to five different scenarios. With a simple touch of a button, you can call upon the preferred setting for your chosen activity.
This product operates as a standard wall-mounted Switch / Dimmer and can be retrofitted into British standard wall box.
ULTI TERMINOLOGYZone - An area illuminated / controlled by a single lighting circuitSwitch - A switch that controls the on-off of a zoneDimmer - A switch that controls the on-off and dimming level of a zoneScene - A “scene” is defined as a combination of lights and electronic appliances
across various zones with different light levels. You can set your favourite scenes by following Programming Procedures in the Handheld Remote Controller Unit manual
ULTI ZigBee Switch 105x105 r14.indd 5 11�11�22� ��2:50
6
OPERATING FUNCTION
Functions of ULTI SwitchULTI allows you to create different scenes and select scenes with ULTI Switch / Dimmer and Handheld Remote Controller Unit. The detailed programming procedures are available in the Handheld Remote Controller Unit manual
2 Gang Switch
1
2
5
7
34
6
1 Gang Switch
1
7
34
65
ULTI ZigBee Switch 105x105 r14.indd 6 11�11�22� ��2:50
7ENGLISH
• Control Buttons 1 and 2 on cover plate- Button 1: Press to toggle the
1st channel on and off- Button 2: Press to toggle the
2nd channel on and off
• Programme Button- Used to enter Programming
mode. Refer to the Handheld Remote Controller Unit Manual
• Clear Button / Programme button indicator- Use to clear programmed
scenes and a status indicator for Programme button. Refer to the Handheld Remote Controller Unit Manual
• Channel LED (2 colour options, amber and blue)- Off = load ON - On = load OFF- Flashing = Channel selected
(during programming)
1-2
3
4
5
6
7
5
• Channel control button- Toggles load during normal
operation. - Selects channel during
programming
• Release Button - Press to release cover plate
Changing LED Backlight Colour
Press and hold the Programme Button for more than 5 seconds. The programme indicator will flash continuously to indicate that the unit is in the local set up mode
Press the channel control button to toggle between amber and blue LED backlight colours
Press the programme button four times in succession to save the selected colour and exit
ULTI ZigBee Switch 105x105 r14.indd 7 11�11�22� ��2:50
8
1. Important:
- Always turn OFF the MCB before installation, maintenance, servicing (or replacing the load) of the switch unit
- Excessive load will damage the product (please refer to the Load Type Table for permissible maximum loading)
2. Make sure the cover plate is separated from the Switch / Dimmer module before installation takes place
3. Make sure there is sufficient depth (40mm) on the wall to install ULTI Switch / Dimmer. A British Standard (BS) wall box must be used for installation
4. Connect the load cables to the Load terminal first and then the power cables to the Live terminal after
5. Fasten the screws of both terminals and make sure wires are properly secured
INSTALLATION PROCEDURES
ULTI ZigBee Switch 105x105 r14.indd 8 11�11�22� ��2:50
9ENGLISH
Cover Plate Removal
1. Push the release button upward to disengage the clip. Release Button is located on the bottom of the Switch / Dimmer module. The cover plate will spring outwards
2. Hold the cover plate and push upwards and away from the Switch / Dimmer module
push upward
6. Directly place ULTI Switch / Dimmer into the wall box and mount it on the wall by fastening the two screws and then put the screw caps on
Note: It is the safety requirement to install plastic caps after screws are fastened.
7. Switch on the power source from the MCB to test the Switch / Dimmer is functioning. LED backlight should turn ON when the Switch / Dimmer is OFF
8. Set your favourite scene by following the programming procedures in the Handheld Remote Controller Unit manual
9. Clip the cover plate back in place
ULTI ZigBee Switch 105x105 r14.indd 9 11�11�22� ��2:50
10
1. Enter Programming Mode 1.1 Remove the cover plate of the
Switch
push upward
1.2 Press the Programme button on the Switch. The Programme LED turns on in green
PROGRAMMING PROCEDURES
PressGreen
2. Select the channel*(inclusion or exclusion from a group/device or scene) and the status of the load (On or Off) by long pressing (>2 seconds) the channel control button on the switch. The LED indicator will flash continuously to indicate the selection
Now you can programme the Handheld Remote controller unit or the FreeLocate to save the selection on the switch (refer to the Programming Procedure of Handheld Remote Controller / FreeLocate)
*- Refer to the table ‘Channel selection and toggle On/Off table’
3. Exit Programming ModeThe saving of a scene or a device on a Handheld Remote Controller or a FreeLocate button exits the programming setup
ULTI ZigBee Switch 105x105 r14.indd 10 11�11�22� ��2:50
11ENGLISH
PROGRAMMING PROCEDURES
4. Reset a Channel or a button:Binding information may be cleared from individual Module channels or Handheld Remote Controller user buttons. This will remove any Scene or Device binding information associated with the button or channel. The device will remain a member of the ZigBee network
To delete all Group or Scene bindings from the button of a Switch:
Step 1. Press the ‘Clear’ Button to enter Clear Mode. Red indicator will turn on
Step 2. Press ‘Channel’ Button that you wish to clear.
Channel indicators will flash to indicate bindings have been deleted
Programme Mode: Channel selection and toggle On/Off table
Switch (button press) Operations while in Program Mode
Short Press Toggle Channel Selected
Long Press Select Channel, Toggle Channel On/Off
Step 2: Press
Step 1: Press Red indicator
Indicator Flash
ULTI ZigBee Switch 105x105 r14.indd 11 11�11�22� ��2:50
12
WIRING DIAGRAM
Live
Load
1
Loop
Live
Load
1
Load
2
Loop
1 Gang 2000VA Switch 2 Gang 2 x 1000VA Switch
Lamp
LiveLive
NeutralNeutral
CapacitorCapacitorCapacitor
IMPORTANT NOTE Install one 275VACX2 safety grade 0.33µF by-pass capacitor across load in parallel if recommended in the load table.
Lamp
ULTI ZigBee Switch 105x105 r14.indd 12 11�11�22� ��2:50
13ENGLISH
WIRING DIAGRAM SPECIFICATION
Description 1 Gang Switch 2 Gang Switch
Safety Compliance IEC 60669-2-1
Operation Toggle on/off
LED Backlight Changeable amber / blue colour
Load Type Please refer to the Load Type Table
Minimum Load Please refer to the Load Type Table
Maximum Load Please refer to the Load Type Table
Operating Temperature 0 °C to + 40 °C
Operating Humidity 0% to 95%
Operating Voltage & Frequency 220 – 240VAC at 50/60Hz
Radio Frequency 2.4GHz, IEEE 802.15.4,
ZigBee-Pro standard
RoHS compliance RoHS directive 2002/95/EC
Mounting Centres 60.3mm
Dimensions (H) x (W) x (D) 87mm x 86mm x 35.2mm
ULTI ZigBee Switch 105x105 r14.indd 13 11�11�22� ��2:50
14
ZIGBEE DEFINITIONS
ZigBee Action User Action on Device
Join Network If not already in a network: Press Prog after first performing “Allow Others to Join
Network” from another device in your installation
Form Network Press Prog
Allow Others to Join Network If already in a network: Press Prog
Restore to Factory Fresh Settings
Hold Clear for > 5 seconds
Pair Devices Not Supported
Enable Identify Mode Press Prog, then Press User button of channel to Identify
Group Nodes Not Supported
Create Scene Not Supported
ULTI ZigBee Switch 105x105 r14.indd 14 11�11�22� ��2:50
15ENGLISH
LOAD TYPE TABLE(S)
Power rating of loads type
The below table lists the minimum and maximum power rating of load type for 1 Gang and 2 Gang switches at following conditions:
Input voltage: 220~240V AC
Ambient temperature: 0 - 40 °C
Load Type
Overall Minimum load rating(W)
Overall maximum load rating(W)
Safety grade capacitor 275VACX2
0.33µF(install in parallel to load on each
gang)
1 Gang
2Gang
1 Gang
2Gang
Incandescent lamp / High voltage halogen lamp
25 25 2000 2000 No
Iron-core/magnetic transformer for low voltage halogen lamp
25 25 1600 1600 No
Electronic transformer for low voltage halogen lamp
25 25 1800 1800 No
Magnetic ballast without power factor correction capacitor for real fluorescent lamp
18 18 800 800 Yes
ZIGBEE DEFINITIONS
ZigBee Action User Action on Device
Join Network If not already in a network: Press Prog after first performing “Allow Others to Join
Network” from another device in your installation
Form Network Press Prog
Allow Others to Join Network If already in a network: Press Prog
Restore to Factory Fresh Settings
Hold Clear for > 5 seconds
Pair Devices Not Supported
Enable Identify Mode Press Prog, then Press User button of channel to Identify
Group Nodes Not Supported
Create Scene Not Supported
ULTI ZigBee Switch 105x105 r14.indd 15 11�11�22� ��2:50
16
3. Temporary disorder. Switch off the MCB and then on again to reset the switch.
Load Type
Overall Minimum load rating(W)
Overall maximum load rating(W)
Safety grade capacitor 275VACX2
0.33µF(install in parallel to load on each
gang)
1Gang
2Gang
1Gang
2Gang
Magnetic ballast with 4µF power factor correction capacitor for real fluorescent lamp
18 18 2000 2000 No
Electronic ballast for real fluorescent lamp
18 18 1800 1800 No
Electronic ballast for real fluorescent lamp (circular type, U type)
13 13 1800 1800 Yes
CFL 7 7 500 500 Yes
Dimmable CFL 7 7 500 500 No
LED 9 9 500 500 Yes
Dimmable LED 9 9 500 500 No
Motor (Ceiling / exhaust fan) 25 25 2A 2A No
For motor load like ceiling sweep fan / exhaust fan, the overall minimum load for 1 Gang and 2 Gang are both 25W. The overall maximum load for 1 Gang and 2 Gang is 2A (approx. 260 W).
LOAD TYPE TABLE(S)
ULTI ZigBee Switch 105x105 r14.indd 16 11�11�22� ��2:50
17ENGLISH
IMPORTANT NOTES FOR LOAD TYPES AND POWER RATINGAll allowable load types are listed in the load table.
The power rating of both, low voltage halogen lamps and their transformers (Iron core or electronic), must meet the minimum load requirement as given in load tables.
The total capacitance of loads is limited to be 140µF.
In case of any flicker in load in OFF condition, it is recommended to use a 275VAC X 2 safety grade 0.33µF by-pass capacitor across load (refer the figure in wiring diagram section).
Use of good quality, International brands of CFL/LED lamps is highly recommended. Use of sub-standard or inferior quality products may result in reduced performance.
PROTECTIONAn external 10A rated current standard MCB should be in series with the main power upfront to protect the switch.
Load Type
Overall Minimum load rating(W)
Overall maximum load rating(W)
Safety grade capacitor 275VACX2
0.33µF(install in parallel to load on each
gang)
1Gang
2Gang
1Gang
2Gang
Magnetic ballast with 4µF power factor correction capacitor for real fluorescent lamp
18 18 2000 2000 No
Electronic ballast for real fluorescent lamp
18 18 1800 1800 No
Electronic ballast for real fluorescent lamp (circular type, U type)
13 13 1800 1800 Yes
CFL 7 7 500 500 Yes
Dimmable CFL 7 7 500 500 No
LED 9 9 500 500 Yes
Dimmable LED 9 9 500 500 No
Motor (Ceiling / exhaust fan) 25 25 2A 2A No
ULTI ZigBee Switch 105x105 r14.indd 17 11�11�22� ��2:50
18
TROUBLE SHOOTING GUIDE
Symptom Possible Cause Solution
Switch/Dimmer is not responding to the FreeLocate Switch
1. Not previously programmed or improper programming
Repeat the Programming Procedures
2. The selector switch on FreeLocate is still in the programming mode
Slide back the selector switch to the In Use position and retry
3. Voltage is too low Make sure the operating voltage range is within the requirement
4. Latency due to presence of another RF network very close to the switch/dimmer
Ensure that there is a minimum of 2 meter distance between another RF network/signal from the unit(s)
5. Another ZigBee network is accidentally created on the FreeLocate
Clear the memory and re-programme the FreeLocate. It’s possible that multiple ZigBee networks are accidentally created while programming
6. Over-loaded / Over temperature protection
When the switch is over-loaded, the switch turns off its output. Please check if the switch is over-loaded and reduce the load to be within specification. Then, power reset the switch
ULTI ZigBee Switch 105x105 r14.indd 18 11�11�22� ��2:50
19ENGLISH
Symptom Possible Cause Solution
Unable to programme
1. Red Programme LED indication after the Programme Button is pressed
This indicates that the FreeLocate is not a part of the network, press the setup button on any one of dimmer/switches in network and press set up button on FreeLocate again to join it in the network
2. The Switch does not receive programming commands
Check the position of the function selector at the back of the FreeLocate Switch. Make sure it is in the Programme position
Switch/Dimmer is not responding to the FreeLocate Switch and LED does not flash
1. Batteries are installed incorrectly or the batteries are low or dead
Replace with new batteries
ULTI ZigBee Switch 105x105 r14.indd 19 11�11�22� ��2:50
20
TROUBLE SHOOTING GUIDE
Symptom Possible Cause Solution
Main light or LED backlight does not turn on
1. Wires are not properly secured or connected in the terminals
Make sure the wires are secured, screws are fastened and the Live or Load wires have been connected to the correct terminals
2. MCB is OFF or has been tripped
Switch on the MCB. If a breaker continually trips, contact a registered electrician to find out the cause of the problem
3. Temporary disorderSwitch off the MCB and then on again to reset the switch
Main load is turned off automatically
1. Power rating is too low
Replace the load that meets the minimum loading requirement
2. Wires are not properly secured in the terminals
Make sure the wires are secured and screws are fastened properly
3. Controlled by other Handheld Remote Controller unit within the area
Determine which Handheld Remote Controller unit(s) is (are) controlling the particular main load. (Refer to Identity, Copy procedures)
ULTI ZigBee Switch 105x105 r14.indd 20 11�11�22� ��2:50