jean favier opera meeting ankara 3/04/09 1 some ecc features studied with genima efficiency with no...

29
Jean Favier OPERA Meetin g Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus fog Distortions effects Sensitivity to grain density Compton or electrons background Neutrino events

Post on 21-Dec-2015

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

1

Some ECC features studied with GenIma

Efficiency with no fog

Efficiencies with fog

Micro-track number versus fog

Distortions effects

Sensitivity to grain density

Compton or electrons background

Neutrino events

Page 2: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

2

• Genima GEN : GEANT3 generation of - single track (1 single field 200x200 2 , double layer emulsion

set-up) - or neutrino, showers events in a complete brick set-up. - The correct grain density is set by randomly eliminating some

GEANT track hits to obtain the m.i.p density at : 34 grains/100) IMA: single “classico” FORTRAN program: - read GEANT hits - add background fog - constructs the 32 images of grains, fog,etc present in the 2

emulsion layers - clusterises the images pixels - finds micro-track - finds base-track

Page 3: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

3

• Fog generation Random generation; fog density from 0 to 30 grains/1000 3

• Clustering

-Emulsion grain : 0.4 radius sphere

-In input, pixels not saturated; then saturation to 256 above a threshold ( about 10 % of the saturated value); for layer 1 the threshold is 20 % lower to take account of light attenuation in emulsion ( att=300 micron)).

Clusters of surface s 4 and s 64 pixels are eliminated

No digital filter (coded but not used for timing reason…)

Page 4: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

4

• Micro-tracks reconstruction

- Initialisation: 2 hits tracks are made with each cluster found in plane 1 to 7 associated with any cluster found in plane 10 to 16.

- Then try to fish other hits in the rest of planes by using roads ; road width depends of the track angle. Fog makes difficult a good evaluation of the residual sigmas

- Select tracks with 6 points and qui2 < 4.5REMARK: for the same physical track, you can obtain more than

one (ex 10) sligthly different micro-tracks. All are kept for base-tracks reconstruction

Page 5: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

5

Residuals

Fog=0

0 mrad 100 mrad

200 mrad 300 mrad

400 mrad 500 mrad

600 mrad

Page 6: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

6

Residuals

fog=8

0 mrad 100 mrad

200 mrad 300 mrad

400 mrad 500 mrad

600 mrad

Page 7: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

7

b

Widening of residuals

when fog increases

Page 8: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

8

Page 9: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

9

Not well adjusted

parameters for sigmas

variation with angle

Page 10: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

10

• Base-tracks reconstruction

-Comparison in the midle plane of the intercepts and the angles of the two tried micro-tracks. x, y S1

slopex, slopey S2

S1=C/ (1-tg ) S2=D/ (1-tg )

- C= 3 micron - D=16 mrad

Page 11: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

11

Base-track efficiency

Fog=0

Page 12: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

12

• How fog can influence efficiency ?- Fog effects will be higher at large angle where the

sensible volume around the track is higher- infection of a good cluster: the resulting barycentre

becomes out of association: the hits number can go down from 6 to 5

- Deformations of good clusters by a fog one can produce a deterioration of qui2

- Oppositely, on a 5 hits track, one fog cluster can, by luck, occupy the sixth rank, so the track will be accepted

Page 13: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

13

Page 14: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

14

Base-track efficiency

Fog effect

Page 15: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

15

Page 16: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

16

Base-track efficiencies when fog increases

Page 17: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

17

• Distortion

It is simulated by random rotation (0 to max) of the

microtracks ,leaving fixed the intercept with the basis; we varied max from 0 to 40 mrad

Emulsion layer 1 basis

Page 18: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

18

Page 19: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

19

Micro-tracks number

Page 20: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

20

Random micro and base tracks with fog

500 mrad cut

700mrad cut

Page 21: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

21

Grain

density

fog=8

0 mrad

400 mrad

Page 22: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

22

Grain

density

Fog=0 (preliminary)

Nhit 6

Nhit 5

Page 23: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

23

Emulsion simulation

• 16 images

Compton

Page 24: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

24

Compton background ( preliminary)

Hall C radio-activity is installed in GEANT3 (Borexino measurements) 1.5 108 gammas cross 1 m2 per day This reduces to 6 gammas per day crossing our field of view. In 1 years: 2000 crossing ( neglecting detector self-screening factor of

400 !!) produce: (based on 50 years stat) - 2 Compton micro-tracks2 Compton micro-tracks in each layer - 0.6-1 have grains in both layers - but: base-track association efficiency 0.05/100! This will result in much less Compton electron background

than electron from lead beta-radioactivity inside detector. ( see internal note J.F 07/10/03)

Page 25: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

25

BRICK EVENT ( preliminary)

Extension of set-up to a full brick; OK (in test)

Scanning and reconstruction OK (in test)

Actual time: 1hour (5600 cm2) for a tau-3h event

Writes micro-tracks parameters ( or clusters ? Or both? ) towards FEDRA ? EMUREC ?(Amina)

in progress….

Page 26: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

26

Tau 3 hadrons Full brick Base-tracks

Page 27: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

27

Tau 3 hadrons 3cm

Page 28: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

28

Electron 2 Gev

Page 29: Jean Favier OPERA Meeting Ankara 3/04/09 1 Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus

Jean Favier OPERA Meeting Ankara 3/04/09

29

Conclusions

• In simulation, no strong fog effect on efficiency. not simulated:the chemistry, stirring, etc of emulsion development!

• Strong distortion effects• Grain density : not confortable• Compton not a problem inside detector; lead

activity sould be dominant. Very low base-track efficiency for low energy electrons.

• Soon: GENIMA neutrino events in Fedra ?