SINGLE TRACK CANTILEVER SLIDING GATES
NOTE: THESE INSTALLATION GUIDELINES ARE BASED ON A LEVEL GRADE FROM OPENING THROUGH ENTIRE ROLL-BACK AREA. DEVIATIONS FROM LEVEL
CONDITIONS (i.e.: curbs, sloped conditions, etc) MUST BE ADDRESSED & ADJUSTED ACCORDINGLY PRIOR TO INSTALLATION OF THE POST ASSEMBLIES
www.jamiesonfence.com
SSAAFFEETTYY PPOOLLIICCYY
JAMIESON MANUFACTURING CO IS COMMITTED TO PROVIDING QUALITY GATE PRODUCTS AND SERVICES. BECAUSE SAFETY IS AN IMPORTANT PART OF
JAMIESON'S DESIGN AND MANUFACTURING CRITERIA, WE FOLLOW THE STANDARDS DEVELOPED BY UNDERWRITER'S LABORATORY (UL325) AND ASTM F2200-02 AS DEVELOPED BY ASTM INTERNATIONAL. WHILE THESE SAFETY STADARDS ARE
SPECIFIC TO AUTOMATED GATES, JAMIESON ALSO CHOOSES TO APPLY THEM TO MANUAL GATES TO RESTRICT HAZARDS SUCH AS PROTRUSIONS, PINCH POINTS AND ENTRAPMENT ZONES IN CASE A GATE IS AUTOMATED AT A LATER DATE. FOR MORE INFORMATION ABOUT JAMIESON GATES, PLEASE NOTIFY YOUR NEAREST JAMIESON
MANUFACTURING CO. OR JAMIESON FENCE SUPPLY REPRESENTATIVE.
COPYRIGHT © 2007 BY JAMIESON MANUFACTURING CO. ALL RIGHTS RESERVED.
NOT PART OF THIS PUBLICATION MAY BE REPORDUCED BY ANY PROCESS, ELECTRONIC OR OTHERWISE, IN ANY MATERIAL FORM OR TRANSMITED TO ANY OTHER PERSON OR STORED ELECTRONICALLY IN ANY FORM, WITHOUT THE PRIOR WRITTEN PERMISSION OF JAMIESON
MANUFACTURING CO.
DO NOT DISABLE , REMOVE OR MODIFY
ANY SAFETY FEATURES FROM THE PRODUCT
DO NOT ADD ANY FEATURES THAT PROTRUDE FROM THE
BODY OF THE GATE GREATER THAN ½”
ALWAYS USE PROPER SAFETY EQUIPMENT WHEN
SERVICING GATE OR GATE HARDWARE
USE PROPER CARE & PRECAUTION AT ALL TIMES WHEN
OPERATING GATES
INSTALL ALL WARNING SIGNS &
PLACARDS NEVER “RIDE” THE GATE
FOR FURTHER INFORMATION
WWW.ASTM.ORG WWW.DASMA.COM
WWW.UL.COM
12300-A AMELIA DRIVE HOUSTON, TX 77045
888/286-3362 WWW.JAMIESONFENCE.COM
THERE IS NO SUBSTITUTE FOR COMMON SENSE
INSIDE FRONT COVER
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
Recommended Tools:
Tape measure Surveyors instrument String line Stakes String line level 24” to 48” Carpenter’s level
Post hole auger (or digger) Cement Trowel Fence Pliers Standard (flat) screwdriver 15/16” Open end wrench 15/16” Socket, ratchet & drive extension ¾” socket or open (or box) end wrench 6” or 8” crescent wrench
Single Track Parts List:
POST TRUCK BRKT. U-BOLT LOWER GUIDE BRKT. COLLECTOR4" ROUND 274003-E4 209007 274005-UL 274011-UL4" SQUARE 274003-E4 209007-SQ 274005-UL 274011-UL
6 5/8" ROUND 274003-E6 200000-265 274005-6 274012-UL6" SQUARE 274003-E6 200000-269 274005-6 274012-UL
TABLE III: HARDWARE GUIDE
WIRE SIZE3/16"1/4">30' 1/2" x 6"
TABLE IV: CABLE TRUSSINGGATE OPENING TURNBUCKLE SIZE
<30' 3/8" x 6"
EXTENDED TRUCK BRACKET(REF. TABLE III)
TABLE 1: TRUCK ASSEMBLY CRITERIA:
TRUSS CABLE(REF. TABLE IV)
BOTTOM HORIZONTAL
CABLE CLAMP
9 GA. SMOOTH WIRE
TENSION BAR
1/4" GUSSETTYP AT EACH CORNER/ EACH BAY
TURNBUCKLE(REF. TABLE IV)
SQUARE/ ROUND UL COLLECTOR(REF. TABLE III)TOP HORIZONTAL
BARBWIRE 4 PT. 12.5 GA.(OPTIONAL)
T6061-T6 ALUM. TRUSS TRAC
LOWER GUIDE BRACKET(REF. TABLE III)
3" UL BOX ROLLERS
> 24'
GATE OPENING
= 24'
274010
PARTNUMBER
274006
10"
LENGTH
6"
8
# BEARINGS/ WHEELS
4
NOTE: ALL SERIES 3000 GATES USE 10" TRUCKS
www.jamiesonfence.com
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
GATE OPENINGFENCE LINE FENCE LINE
ENTRY
EXIT
POINT A POINT B
SECURED AREA(INSIDE PROPERTY LINE)
UNSECURED AREA(OUTSIDE PROPERTY LINE)
STRING LINE
FENCE LINE ALIGN STRINGLINETO OUTSIDE POST
SURFACE
LINE/ENDPOST
GATE OPENINGFENCE LINE FENCE LINE
DID YOU KNOW?
JAMIESON GATES CAN BE INSTALLED FOR OPEN/CLOSE IN EITHER DIRECTION
ENTRY
EXIT
STEP 1: LAYOUT WORK AREA. ENSURE:
a) LEVEL GRADE (IF POSSIBLE). b) ADEQUATE SPACE IN DRAWBACK AREA. c) OBSTRUCTIONS CLEARED.
SECURED AREA(INSIDE PROPERTY LINE)
UNSECURED AREA(OUTSIDE PROPERTY LINE)
(APPROXIMATELY 50% OF GATE OPENING)
DRAWBACK AREA
COUNTERBALANCE AREA
= OVER ALL LENGTH OF GATE + CLEARANCE(TYPICALLY 1-12 x THE GATE OPENING)
INCLUDE POST SET BACK DISTANCE FROM CURB & ROADWAYEACH SIDE OF GATE OPENING
STEP 2: SIZE THE GATE ACCORDING TO THE GATE OPENING. INCLUDE CLEARANCES REQUIRED TO CLEAR THE CURB AND ROADWAY.
CURB CUTOUTS MAY BE REQUIREDTO MAINTAIN MINIMUM CLEARANCEBETWEEN BOTTOM OF GATE ANDGRADE
STEP 3: TO DETERMINE THE OUTSIDE FACE OF THE GATE POSTS, USE STRING LINE, SURVEYORS INSTRUMENT, OR OTHER ACCEPTABLE MEANS TO ESTABLISH A REFERENCE PLANE FROM POINT A TO POINT B (ACROSS COUNTERBALANCE AREA THROUGH GATE OPENING)
THE OVER ALL LENGTH OF A CANTILEVER GATE IS TYPICALLY 1.5 x THE GATE OPENING.
PG 1 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
FENCE LINE FENCE LINE
UNSECURED AREA(OUTSIDE PROPERTY LINE)
STRING LINE
GATE OPENINGINSIDE-TO-INSIDE MEASURE
(INCLUDING CLEARANCE)
FENCE LINE FENCE LINE
ENTRY
EXIT
STEP 5: MEASURE FROM INSIDE FACE OF LATCH POST ACCROSS ROADWAY TO MARK INSIDE FACE OF FRONT CANTILEVER GATE POST ON OPPOSITE SIDE OF ROADWAY
SECURED AREA(INSIDE PROPERTY LINE)
DID YOU KNOW? JAMIESON GATES CAN BE INSTALLED ON OUTSIDE OF FENCELINE. CONTACT YOUR JAMIESON DEALER PRIOR TO ORDER FOR MORE INFORMATION.
12 OF GATE OPENING
(TO INSIDE OF LATCH POST)
LAYOUT POST HOLES
FENCE LINE FENCE LINE
ENTRY
EXIT
12 OF LATCH POST DIAMETER
STEP 4: SET MARKER FOR LATCH POST AT DESIRED LOCATION (OUTSIDE OF ROADWAY & CURB). (DISTANCE FROM CENTER OF ROADWAY SHOULD MEASURE 1/2 OF DESIRED GATE OPENING).
IMPORTANT: THE GATE OPENING MEASUREMENT IS FROM
INSIDE POST TO INSIDE POST
PG 2 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
DID YOU KNOW? JAMIESON SUPPLIES INSTALLATION TOOLS. CONTACT YOUR JAMIESON DEALER PRIOR TO ORDER FOR MORE INFORMATION.
GATE OPENINGCANTILEVER POST SPACEOUTSIDE-TO-OUTSIDE MEASURE
FENCE LINE FENCE LINE
ENTRY
EXIT
STEP 6: LOCATE BACK CANTILEVER POST (REFERENCE CHART)
UNSECURED AREA(OUTSIDE PROPERTY LINE)
SECURED AREA(INSIDE PROPERTY LINE)
STEP 7: EXCAVATE POST FOOTINGS
GATE OPENINGCANTILEVER POST LOCATIONS
LATCH POSTLOCATION
FINISHED GRADE
FOOTING DIA = 4x POST DIA MINIMUM UNLESS OTHERWISE SPECIFIED
AERIAL VIEW
ELEVATION VIEW
FOOTING DEPTH 3 FT MIN(6" DEEPER THAN POST DEPTH) UNLESS OTHERWISE SPECIFIED
IMPORTANT:CANTILEVER POST SPACINGS ARE FROM
OUTSIDE-TO-OUTSIDE OF POST!!
40'-0" 16'-0" 58'-0"
36'-0" 15'-0" 53'-0"38'-0" 15'-0" 55'-0"
32'-0" 14'-0" 48'-0"34'-0" 14'-0" 50'-0"
28'-0" 12'-0" 42'-0"30'-0" 13'-0" 45'-0"
24'-0" 11'-0" 36'-0"26'-0" 12'-0" 39'-0"
20'-0" 9'-0" 30'-0"22'-0" 10'-0" 33'-0"
16'-0" 7'-0" 24'-0"18'-0" 8'-0" 27'-0"
12'-0" 5'-0" 18'-0"14'-0" 6'-0" 21'-0"
8'-0" 3'-0" 12'-0"10'-0" 4'-0" 15'-0"
TABLE I: GATE SPECSGATE OPENING POST SPACING GATE OAL
PG 3 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
GATE OPENING
LATCH POST
MEASURE BOTH HIGHAND LOW TO ENSURE
POSTS PARALLEL
STEP 8: POSITION POSTS IN EXCAVATED FOOTINGS USING STRING LINE AND LEVEL AS A GUIDE. BRACE THE POSTS TO ENSURE THEY STAY LEVEL, CO-LINEAR & PARALLEL
USE LEVEL IN PLANE OF FENCE LINE AND PERPENDICULAR TO FENCE LINE
BLOCK 6" OFFBOTTOM OF
FOOTING HOLE
TEMPORARY BRACING TO ENSURE POST STAY AT
TRUE VERTICAL
NOTE: DOUBLE CHECK ALL DIMENSIONS BEFORE NEXT STEP
GATE OPENING
STEP 9: POUR CONCRETE
CROWN CONCRETETO SHED WATER
GATE OPENING
STEP 10: REMOVE BRACING AND CLEAN UP WORK AREA
DID YOU KNOW? JAMIESON SELLS CONCRETE & BRACING FOR YOUR INSTALLATION NEEDS. CONTACT YOUR NEAREST JAMIESON FENCE SUPPLY DEALER FOR DETAILS.
PG 4 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
MEASURE HEIGHT FROM GATE BOTTOM TO TOP INSIDE SURFACE OF
TRACK
U-BOLT
2" x 5" RECTANGULARBOTOM FRAME
OUTSIDEFENCELINE(UNSECURED)
TRUCK & TRUCK BRACKET
ALUMINUM TRACK/FRAME MEMBER
+ 3"
= HEIGHT TO SET BRACKET ABOVE
GRADE
a) MEASURE DISTANCE FROM THE BOTTOM OF THE GATE TO THE BOTTOM INSIDE SURFACE OF THE ALUMINUM TRACK
THIS SURFACESTEP 8: ATTACH TRUCK BRACKETS TO POST
- 3"TYPICAL GAPABOVE GRADE
CANTILEVER GATE POST
b) SINCE THE DISTANCE FROM THE TOP OF THE BRACKET TO THE TOP OF THE TRUCK IS OFFSET BY THE CLEARANCE BETWEEN THE BOTTOM OF THE GATE & THE GRADE ...
b) ... MOUNT EACH BRACKET TO A CANTILEVER POST USING THE U-BOLTS PROVIDED A DISTANCE EQUAL TO THAT MEASURE IN STEP 8a.
CANTILEVER GATE
PG 5 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
OUTSIDEFENCELINE(UNSECURED)
TRUCK & TRUCK BRACKET
SET HEIGHT TO 3"
a) REMOVE LOCKNUT FROM TRUCK MOUNTING BOLTb) FIT TRUCK MOUNTING BOLT INTO MATING HOLE ON BRACKET c) USE ADJUSTING NUT TO SET HEIGHT TO APPROX 3" AS SHOWNd) REPLACE LOCKNUT AND TIGHTEN
STEP 9: MOUNT TRUCKS ONTO BRACKETS
REPEAT FOR 2ND TRUCK
e) STRETCH STRINGLINE BETWEEN TRUCKS OR BRACKETSf) USING LINE LEVEL TO CHECK IF LEVELg) ADJUST TRUCKS AS REQUIRED
LOCKNUT
ADJUSTING NUT
STEP 9b: CHECK LEVEL ACCROSS TRUCKS
STEP 10: MOUNT GATE
NOTE: GATE CAN BE INSTALLED FROM GATE OPENING SIDE OR DRAWBACK AREA SIDE- WHICHEVER IS MORE OPEN OR CONVENIENT.
> STAND GATE UPRIGHT> POSITION ENCLOSED TRACK ON GATE IN LINE WITH TRUCKS.> REMOVE CARRIAGE BOLT & NUT FROM END OF TRACK> ELEVATE GATE FOR TRUCKS TO ENTER TRACK> SLIDE GATE ONTO TRUCKS> CENTER GATE ON CANTILEVER POSTS> REPLACE CARRIAGE BOLT STOP AT END OF TRACK
NOTE: GATE IS HEAVY AND UNSTABLE. USE CAUTION WHEN MOVING. REQUIRES THE USE OF CRANE, FORKTRUCK, BOBCAT OR OTHER LIFTING & MOVING EQUIPMENT.
PG 6 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
GATE OPENING
BACKCANTILEVER
POST
> PLACE LEVEL ON TOP SURFACE OF GATE BETWEEN CANTILEVER POSTS> ADJUST TRUCK LEVELLING NUTS UNTIL GATE HANGS LEVEL (REF DRAWING IN STEP 9)> TIGHTEN TRUCK LOCKNUTS
STEP 11: MOUNT LOWER ROLLER GUIDE & LEVEL GATE IN VERTICAL PLANE BY ADJUSTING ROLLERS APPROPRIATELY IN THE LOWER GUIDE SLOT
FRONTCANTILEVER
POST
LATCHPOST
STEP 13: LEVEL GATE IN CENTERED POSITION (CENTERED ON CANTILEVER GATE POSTS)
ADJUST ROLLER IN/OUTTO MAKE GATE VERTICAL
LEVEL
MOUNT LOWER GUIDETO POST WITH UBOLTPROVIDED
MINIMAL CLEARANCE
GATE WILL WANT TOLIST IN THIS DIRECTION
BEFORE ADJUSTING GUIDE WHEELS
INSTALL 2ND GUIDE ROLLER
DO NOT OVER-TIGHTENBACK GUIDEWHEEL SHOULD HAVE AIR SPACEBETWEEN FRAME & ROLLER
STEP 12: CHECK TENSION ON TRUSS CABLES
1
2
3
LEVEL
WITH GATE STILL IN CENTERED POSITION, ADJUST TURNBUCKLES SO THAT TRUSS CABLES ARE EVENLY TENSIONED (APPROXIMATELY 14" DEFLECTION)
GATE OPENING
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
LATCHPOST
NOTE: DO NOT OVERTIGHTEN CABLES AT THIS POINT
REPEAT PROCEDURE FOR 2ND CANTILEVER GATE POST
LOWER GUIDE INSTALLED ON 6-5/8” RND POST
PG 7 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
STEP 14: TRUSS CABLE ADJUSTMENT (1st SIDE) (GATE IN CENTERED POSITION UNTIL STEP 16)
VISUALIZE DIVIDING LINE IN MIDDLE OF GATE. EACH HALF IS ADJUSTED SEPERATELY & AS A MIRROR IMAGE OF EACH OTHER.
GATE OPENING
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
LATCHPOST
ADJUST FRONT OF GATE TOLEVEL OR SLIGHT LIFT
PULL THE FRONT HALF OF THE GATE UP INTO A "SMILE" BY TIGHTENING THE FRONT TURNBUCKLES
GATE OPENING
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
LATCHPOST
TIGHTEN THESE TURNBUCKLES PULLING IN THIS DIRECTION. NOTE: YOU CAN EITHER TIGHTEN FROM THE NOSE TO THE CENTER OR FROM THE CENTER OUT.
DO NOT ADJUST(NOTE: THESE CABLES WILL BECOME SLACK ASTHE OPPOSING CABLE IS TIGHTENED. DO NOT TAKE THE SLACK OUT OF THESE CABLES..
ON THE FRONT SIDEOF THE GATE, CABLES
ORIENTED IN THIS DIRECTION WILL PULL
THE GATE UP
ADJUST FRONTHALF OF GATE FIRST
FRONT HALF OF GATE
IF GATE HAS EXTENSIVE "SAG",YOU MAY CHOOSE TO USE A "HOUSE JACK" OR BLOCK &
PRY-BAR TO ELEVATE THE FRONTHALF OF THE GATE. THIS WILL
REDUCE THE AMOUNT OF TENSIONON THE TRUSS CABLE, MAKING IT
EASIER TO ADJUST
CL
LIFT TO LEVEL ORPLACE IN SLIGHT "SMILE"
AFTER TRUSS CABLE ADJUSTMENT ON THIS SIDE, CHECK WITH LEVEL TO ENSURE GATE DOES NOT SAG OR HAS SLIGHT SMILE.
GATE OPENING
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
LATCHPOST
MAKE WHATEVER ADJUSTMENTSNECESSARY TO BRING GATE INTO
PROPER POSITION
FRONT HALF OF GATE
CL
CL
LEVEL
PG 8 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
STEP 15: TENSION TRUSS CABLES (2nd SIDE) (GATE STILL IN CENTERED POSITION)
NOW ADJUST BACK HALF OF GATE. ADJUSTMENT PROCEDURE IS A MIRROR IMAGE OF THAT DONE IN STEP 14.
GATE OPENING
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
ADJUST BACKOF GATE TOLEVEL OR SLIGHT LIFT
PULL THE BACK HALF OF THE GATE UP INTO A "SMILE" BY TIGHTENING THE BACK TURNBUCKLES
GATE OPENING
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
TIGHTEN THESE TURNBUCKLESNOTE: YOU CAN EITHER TIGHTEN FROM THE NOSETO THE CENTER OR FROM THE CENTER OUT.
DO NOT ADJUST(NOTE: THESE CABLES WILL BECOME SLACK ASTHE OPPOSING CABLE IS TIGHTENED. DO NOT TAKE THE SLACK OUT OF THESE CABLES..
ON THE BACK SIDEOF THE GATE, CABLES
ORIENTED IN THIS DIRECTION WILL PULL
THE GATE UP
ADJUST BACKHALF OF GATE FIRST
BACK HALF OF GATE
IF GATE HAS EXTENSIVE "SAG",YOU MAY CHOOSE TO USE A "HOUSE JACK" OR BLOCK &
PRY-BAR TO ELEVATE THE FRONTHALF OF THE GATE. THIS WILL
REDUCE THE AMOUNT OF TENSIONON THE TRUSS CABLE, MAKING IT
EASIER TO ADJUST
CL
LIFT TO LEVEL ORPLACE IN SLIGHT "SMILE"
AFTER TRUSS CABLE ADJUSTMENT ON THIS SIDE, CHECK WITH LEVEL TO ENSURE GATE DOES NOT SAG OR HAS SLIGHT SMILE.
GATE OPENING
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
MAKE WHATEVER ADJUSTMENTSNECESSARY TO BRING GATE INTO
PROPER POSITION
BACK HALF OF GATE
CL
CL
LEVEL
PG 9 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
GATE OPENING
LATCH POSTNOT SHOWN
FOR ILLUSTRATIONPURPOSES
STEP 16: ADJUST TRUSS CABLES IN EXTENDED POSITIONS (GATE EXTENDED IN CLOSED POSITION)
VISUALIZE DIVIDING LINE AT FRONT CANTILEVER GATE POST.
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
AS DONE IN STEP 14, ADJUST THE FRONT HALF OF THE GATE UP TO LEVEL OR A "SMILE" BY TIGHTENING THE FRONT TURNBUCKLES
TIGHTEN THESE TURNBUCKLESNOTE: YOU CAN EITHER TIGHTEN FROM THE NOSETO THE CENTER OR FROM THE CENTER OUT.
DO NOT ADJUST(NOTE: THESE CABLES WILL BECOME SLACK ASTHE OPPOSING CABLE IS TIGHTENED. DO NOT TAKE THE SLACK OUT OF THESE CABLES..
ON THE FRONT SIDEOF THE GATE, CABLES
ORIENTED IN THIS DIRECTION WILL PULL
THE GATE UP
ADJUST FRONTHALF OF GATE FIRST
IF GATE HAS EXTENSIVE "SAG",YOU MAY CHOOSE TO USE A "HOUSE JACK" OR BLOCK &
PRY-BAR TO ELEVATE THE FRONTHALF OF THE GATE. THIS WILL
REDUCE THE AMOUNT OF TENSIONON THE TRUSS CABLE, MAKING IT
EASIER TO ADJUST
LIFT TO LEVEL ORPLACE IN SLIGHT "SMILE"
THEN CHECK WITH LEVEL TO ENSURE GATE MAINTAINS LEVEL OR HAS SLIGHT SMILE.
LATCHPOST
MAKE WHATEVER ADJUSTMENTSNECESSARY TO BRING GATE INTO
PROPER POSITION
LEVEL
GATE OPENING
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
FRONT HALF OF GATE
EXTEND GATE TO FULLY CLOSED POSITION
GATE OPENING
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
FRONT HALF OF GATE
PG 10 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
THE REST OF THE GATE OPENING AND
LATCH POSTNOT SHOWN
FOR ILLUSTRATIONPURPOSES
STEP 17: FINAL ADJUSTMENT OF TRUSS CABLES (GATE EXTENDED IN OPEN POSITION)
VISUALIZE DIVIDING LINE AT BACK CANTILEVER GATE POST.
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
AS DONE IN STEP 15, ADJUST THE BACK HALF OF THE GATE UP TO LEVEL OR A "SMILE" BY TIGHTENING THE BACK TURNBUCKLES
TIGHTEN THESE TURNBUCKLESNOTE: YOU CAN EITHER TIGHTEN FROM THE NOSETO THE CENTER OR FROM THE CENTER OUT.
DO NOT ADJUST(NOTE: THESE CABLES WILL BECOME SLACK ASTHE OPPOSING CABLE IS TIGHTENED. DO NOT TAKE THE SLACK OUT OF THESE CABLES..
ON THE BACK SIDEOF THE GATE, CABLES
ORIENTED IN THIS DIRECTION WILL PULL
THE GATE UP
ADJUST BACKHALF OF GATE
IF GATE HAS EXTENSIVE "SAG",YOU MAY CHOOSE TO USE A "HOUSE JACK" OR BLOCK &
PRY-BAR TO ELEVATE THE FRONTHALF OF THE GATE. THIS WILL
REDUCE THE AMOUNT OF TENSIONON THE TRUSS CABLE, MAKING IT
EASIER TO ADJUST
LIFT TO LEVEL ORPLACE IN SLIGHT "SMILE"
THEN CHECK WITH LEVEL TO ENSURE GATE MAINTAINS LEVEL OR HAS SLIGHT SMILE.
MAKE WHATEVER ADJUSTMENTSNECESSARY TO BRING GATE INTO
PROPER POSITION LEVEL
NOW EXTEND GATE TO FULLY OPEN POSITION
GATE OPENINGGATE IN FULLY
OPEN POSTITION
THE REST OF THE GATE OPENING AND
LATCH POSTNOT SHOWN
FOR ILLUSTRATIONPURPOSES
BACKCANTILEVER
POST
FRONTCANTILEVER
POST
ADJUST BACKHALF OF GATE
GATE OPENINGGATE IN FULLY
OPEN POSTITION
THE REST OF THE GATE OPENING AND
LATCH POSTNOT SHOWN
FOR ILLUSTRATIONPURPOSES
BACKHALF
OF GATE
GATE OPENINGGATE IN FULLY
OPEN POSTITION
PG 11 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
STEP 18: MOUNT COLLECTOR ON LATCH POST
STEP 19: MOUNT SAFETY FILLER PLATES ON BOTH CANTILEVER POSTS USING APPROPRIATE TENSION OR BRACE BANDS.
SAFETYFILLERPLATE
48" MINABOVE GRADE.
LATCH POST & CAP
COLLECTOR
U-BOLT
42" TO 48" ABOVE GRADE(TYPICAL)
ROUND LATCH POST
TENSIONBANDS
PER ASTM F2200-02 SPECIFICATIONS,"... ALL OPENINGS SHALL BE DESIGNED, GUARDED OR SCREENED FROM THE BOTTOM OF THE GATE TO A MINIMUM OF 48" ABOVE GRADE TO PREVENT A 2-14" DIAMETER SPHERE FROM PASSING
THROUGH THE OPENINGS ANYWHERE IN THE GATE, AND IN THAT PORTION OF THE ADJACENT FENCE THAT THE GATE COVERS IN
THE OPEN POSITION..."
PG 12 OF 12
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
MAINTENANCE GUIDELINES
Jamieson gate systems are relatively maintenance free. However, it is suggested that the following be reviewed semi-annually to ensure trouble free
gate operation: o Check attachment, alignment and proper working order of all trucks, brackets
& hardware. o Check vertical alignment of posts. Ensure integrity of the footing and crown. o Check alignment of gate to collector and lower guides Ensure gate is level and
true. o Operate gates in both directions checking for sagging, binding or grinding
noises. Adjust truss cable tension as necessary, but do not over-tighten. o Ensure the enclosed TrusTrac™ is free of debris o Visually inspect truck assemblies to clean dirt/debris and ensure integrity.
Note that the trucks use sealed bearing and require no grease or periodic maintenance.
o Visually check all safety devises (protective guides, safety loops, etc.). Replace or correct as required.
For all automated gates, refer to the manufacturer’s Operator Manual for recommended maintenance and safety practices. For any questions or technical assistance, please contact your nearest Jamieson representative.
1 YEAR LIMITED WARRANTY Jamieson Manufacturing Co. (“Jamieson”) warrants only that its gates will be free from defects in material and workmanship under normal use for a period of one (1) year from date of shipment if, but only if, the gate has been properly installed and operated. Jamieson’s obligation under this warranty is limited to, at Jamieson’s option, the repair or exchange of any part appearing to its satisfaction to be defective in material or workmanship or the refund of the purchase price if Jamieson is unable, by repair or replacement, to make the gate operate in a normal manner under normal use. This limited warranty does not obligate Jamieson to bear any transportation, shipping, removal, installation or other expenses in connection with such gate or the inspection, repair or replacement of any defective parts. To obtain warranty service, purchaser must deliver the gate or defective part to Jamieson’s facility or other point designated by Jamieson. THIS LIMITED WARRANTY IS PURCHASER’S EXCLUSIVE REMEDY. It is extended only to the original purchaser and is non-transferable and non-assignable to any other purchaser or subsequent owner. THIS LIMITED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL OR IMPLIED (INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR USE AND THOSE ARISING FROM COURSE OF PERFORMANCE, DEALING OR USAGE) AND OF ALL OTHER OBLIGATIONS OR LIABILITIES OF JAMIESON. JAMIESON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS GATE. THIS LIMITED WARRANTY SHALL NOT APPLY TO THIS GATE OR ANY PART THEREOF WHICH HAS BEEN SUBJECT TO (1) ACCIDENT, NEGLECT, ALTERATION, ABUSE, MISUSE, OR IMPROPER INSTALLATION, OPERATION OR SERVICE; (2) DAMAGE BY FLOOD, FIRE, OTHER CASUALTY, ACTS OF GOD, RIOTS, INSURRECTIONS, WAR OR TERRORISM; OR (3) USE IN HARSH INDUSTRIAL, COASTAL OR MARINE ENVIRONMENTS. SOME STATES DO NOT ALLOW LIMITATIONS ON IMPLIED WARRANTIES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. JAMIESON MAKES NO WARRANTY WHATSOEVER IN RESPECT TO ACCESSORIES, COMPONENT PARTS OR ATTACHMENTS NOT MANUFACTURED OR SUPPLIED BY JAMIESON, INCLUDING BUT NOT LIMITED TO, ACCESS CONTROL GATE OPERATORS AND RELATED HYDRAULIC AND ELECTRONIC SYSTEMS. ALL SUCH ITEMS ARE SOLD TO PURCHASER ON AN “AS-IS” BASIS, EXCEPT TO THE EXTENT OF ANY WARRANTY GIVEN TO JAMIESON BY THE ACTUAL MANUFACTURER. THIS LIMITED WARRANTY EXCLUDES ALL COSTS ARISING FROM ROUTINE MAINTENANCE, INCLUDING REPLACEMENT PARTS REQUIRED FOR ROUTINE MAINTENANCE. Jamieson reserves the right to modify, alter or improve its gates, or parts thereof, at any time without incurring any obligation to modify, alter, improve or replace the gate or any parts thereof, previously sold. Jamieson shall not be liable for normal manufacturing defects, customary variations from specifications, or defects arising from designs or other specifications supplied by Purchaser. IT IS UNDERSTOOD AND AGREED THAT JAMIESON’S LIABILITY AND PURCHASER’S SOLE REMEDY, WHETHER IN CONTRACT, UNDER ANY WARRANTY, IN TORT (INCLUDING NEGLIGENCE), IN STRICT LIABILITY OR OTHERWISE SHALL NOT EXCEED THE RETURN OF THE AMOUNT OF THE PURCHASE PRICE PAID BY PURCHASER, AND UNDER NO CIRCUMSTANCES SHALL JAMIESON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, PERSONAL INJURY, PROPERTY DAMAGE, DAMAGE TO OR LOSS OF EQUIPMENT, LOST PROFITS OR REVENUE, AND OTHER ADDITIONAL EXPENSES, EVEN IF JAMIESON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE PRICE STATED FOR THE GATE IS A CONSIDERATION IN LIMITING JAMIESON’S LIABILITY. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. JAMIESON WILL NOT BE LIABLE FOR ANY DAMAGES, LOSSES, OR EXPENSES AS A RESULT OF PURCHASER’S NEGLIGENCE, WHETHER DEEMED ACTIVE OR PASSIVE AND WHETHER OR NOT ANY SUCH NEGLIGENCE IS THE SOLE CAUSE OF ANY SUCH DAMAGE, LOSS OR EXPENSE. NO WAIVER, ALTERATION, OR MODIFICATION OF THE FOREGOING CONDITIONS SHALL BE VALID UNLESS MADE IN WRITING AND SIGNED BY AN EXECUTIVE OFFICER OF JAMIESON. THIS WARRANTY SHALL APPLY ONLY WITHIN THE BOUNDARIES OF THE CONTINENTAL UNITED STATES AND CANADA. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. Advice of Jamieson’s technical staff may be available to the trade, but Jamieson, not controlling or supervising the subsequent installation of itsproducts or their use after sale, does not warrant or guarantee such advice. SPECIAL ORDERS: If any material shall be manufactured and/or sold by Jamieson to meet Purchaser’s particular specifications or requirements, Purchaser shall defend, protect, and save harmless Jamieson against all suits at law or in equity and from all damages, claims, and demands for actual or alleged infringement of any United States or foreign patent and shall defend any suit or actions which may be brought against Jamieson for any alleged infringement because of the manufacture and/or sale of the material covered thereby.
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
JAMIESON HISTORY
(TYP INSIDE BACK COVER)
INSIDE BACK COVER
JAMIESON MANUFACTURING CO.
TRUSTRAC™ INSTALLATION GUIDE
www.jamiesonfence.com
BRANCH MAP
(TYP BACK COVER)
BACK COVER