james gardner rt(r), ba. what is quality improvement? it is the combined and unceasing efforts of...

47
What is Quality Improvement? James Gardner RT(R), BA

Upload: kevon-skipton

Post on 14-Dec-2015

215 views

Category:

Documents


1 download

TRANSCRIPT

  • Slide 1

James Gardner RT(R), BA Slide 2 What is Quality Improvement? It is the combined and unceasing efforts of everyonehealthcare professionals, patients and their families, researchers, payers, planners and educatorsto make the changes that will lead to better patient outcomes, better system performance and better professional development.. healthcare will not realize its full potential unless change making becomes an intrinsic part of everyone's job, every day, in all parts of the system. Qual Saf Health Care. 2007 February; 16(1): 23. doi: 10.1136/qshc.2006.022046 Slide 3 Shady Grove defines quality as: State and Federal Reporting Management of Accreditation(Joint Commission & CMS) Quality of Care Complaints Core Measures Patient Safety Performance Improvement Proactive Risk Analysis (FMEA) Reactive Risk Analysis (RCA) Hospital Committee Facilitation Peer Review for Medical Staff Quality Department Core Operations Quality is Everyones Responsibility! Slide 4 Core Measures Are metrics that monitor the use of recommended treatments that scientific evidence shows produce the best results. Heart Failure, Pneumonia, Venous Thromboembolism (VTE), AMI, Surgical Care Improvement Project (SCIP), Immunization and ED throughput Slide 5 Slide 6 Process Improvement Plan the improvement Do the improvement Check the results of our PI actions Act to maintain the improvement (*or if the improvement did not have the desired effect, modify it and try again) Slide 7 F ailure M ode & E ffect A nalysis ( FMEA ) & R oot C ause A nalysis ( RCA ) You may be asked to participate in Process Improvement: FMEA Systematic Proactive Team Approach Process Driven RCA Systematic Reactive Team Approach Process Driven Slide 8 Slide 9 How can I impact quality improvement? Ask Questions Advocate for Patients Be Thorough Document EVERYTHING Dont take Shortcuts Follow HIPAA Always follow the Golden Rule of Patient Care Slide 10 The Golden Rule of Patient Care Do the right thing, the right way, the first time, every time! Slide 11 Slide 12 Scope of Practice What you are legally permitted to do as a licensed and registered Technologist. Varies per State AND per Institution Based off of Practice Standards established by the ASRT Reinforced and supported by institutional policies, processes and procedures. Slide 13 Slide 14 National Patient Safety Goals: Patient Identification Critical Results Communication Hand Off Communication Health Care Associated Infections (HAI) Universal Protocol: Time Out Alarms Slide 15 Joint Commission Survey Readiness Contrast MUST be distributed through the pharmacy. MRI rooms MUST have 2 barriers between hallway and MRI unit. Dont make your policies to restrictive or hard to comply withless is more. Perform and Document a timeout prior to every invasive procedure. Informed Consent Doctor informs, anyone can sign, MUST be prior to procedure. NEVER store anything in the hallways. Does your facility do Prostate Seeding? What is you process for communicating critical results. Staff does Job specific competencies. Slide 16 MUST be a Consent to Treat. MUST time/date/sign all entries in the medical record. MUST document patient education & pregnancy consent. MUST document sequentially. MUST observe infection control guidelines/policies (Hand washing, contact precautions, etc). MUST follow oxygen storage guidelines (12 total cylinders seperated by full or partial/empty). MUST keep code carts up to date. NEVER store anything within 18 of a sprinkler head. Joint Commission Survey Readiness Slide 17 New Radiology Standards and EPs EC.02.01.01 The hospital manages safety and security risks. EP 14: For hospitals that provide magnetic resonance imaging (MRI) services: The hospital manages safety risks in the MRI environment associated with the following: Patients who may experience claustrophobia, anxiety, or emotional distress Patients who may require urgent or emergent medical care Metallic implants and devices Ferrous objects entering the MRI environment Slide 18 EC.02.01.01 EP 16: For hospitals that provide magnetic resonance imaging (MRI) services: The hospital manages safety risks by doing the following: Restricting access of everyone not trained screened by staff to an area that immediately precedes the entrance to the MRI scanner room. Making sure that this area is controlled by and under the direct supervision MRI trained staff Posting signage at the entrance to the MRI scanner room that conveys that the magnet is always on Slide 19 EC.02.02.01 The hospital manages risks related to hazardous materials and waste. EP 17: For hospitals that provide computed tomography (CT), positron emission tomography (PET), or nuclear medicine (NM) services: The hospital monitors radiation exposure levels for all staff and licensed independent practitioners who routinely work in CT, PET, and NM areas. Note: This is typically done through the use of exposure meters, such as personal dosimetry badges. Slide 20 EC.02.04.01 The hospital manages medical equipment risks. EP 7: The hospital identifies activities and frequencies to maintain the image quality of the diagnostic images produced. The content and frequency of these activities are in accordance with state regulatory requirements, manufacturers guidelines, and the recommendations of a medical physicist. Slide 21 EC.02.04.03 The hospital inspects, tests, and maintains medical equipment. EP 15: The hospital maintains the image quality of the diagnostic images produced. EP 17: For hospitals that provide computed tomography (CT) services: When utilizing standard adult brain, adult abdomen, and pediatric brain protocols, a qualified medical physicist measures the actual radiation dose produced by each diagnostic CT imaging system at least annually and verifies that the radiation dose displayed on the system is within 20 percent of the actual amount of radiation dose delivered. The dates of these verifications are documented. Slide 22 EC.02.04.03 EP 17: Note: This element of performance is applicable only for systems capable of calculating and displaying radiation doses. EP 19: For hospitals that provide computed tomography (CT) services: If the hospital does not utilize standard adult brain, adult abdomen, or pediatric brain protocols, the hospital uses a qualified medical physicist to measure the actual radiation dose produced by each diagnostic CT imaging system at least annually and verify that the radiation dose displayed on the system is within 20 percent of the actual amount of radiation dose delivered for the three most common CT protocols used by the hospital. The dates of these verifications are documented. Slide 23 EC.02.04.03 EP 20: For hospitals that provide computed tomography (CT) services: At least annually, a medical physicist conducts a performance evaluation of all CT imaging equipment. The evaluation results, along with recommendations for correcting any problems identified, are documented. The evaluations include the use of phantoms to assess the following imaging metrics: - Image uniformity - Slice thickness accuracy - Slice position accuracy - High-contrast resolution - Low-contrast resolution - Geometric or distance accuracy - CT number accuracy and uniformity - Artifact evaluation Slide 24 EC.02.04.03 EP 21: For hospitals that provide magnetic resonance imaging (MRI) services: At least annually, a medical physicist or MRI scientist conducts a performance evaluation of all MRI imaging equipment. The evaluation results, along with recommendations for correcting any problems identified, are documented. The evaluations include the use of phantoms to assess the following imaging metrics: - Image uniformity - Slice thickness accuracy - Slice position accuracy - High-contrast resolution - Low-contrast resolution (or contrast- to-noise ratio) - Geometric or distance accuracy - Magnetic field homogeneity (for MRI) - Artifact evaluation Slide 25 EC.02.04.03 EP 22: For hospitals that provide positron emission tomography (PET) or nuclear medicine (NM) services: At least annually, a medical physicist conducts a performance evaluation of all imaging equipment. The evaluation results, along with recommendations for correcting any problems identified, are documented. The evaluations include the use of phantoms to assess the following imaging metrics: - Image uniformity - Extrinsic or system uniformity - Intrinsic or system spatial resolution - Low-contrast resolution - Sensitivity - Energy resolution - Count-rate performance - Artifact evaluation Slide 26 EC.02.06.05 The hospital manages its environment during demolition, renovation, or new construction to reduce risk to those in the organization. EP 4: For hospitals that provide computed tomography (CT), positron emission tomography (PET), or nuclear medicine (NM) services: The hospital conducts a shielding integrity survey of rooms where ionizing radiation will be emitted or radioactive materials will be used or stored (for example, scan rooms, injection rooms, hot lab). Note: For additional guidance on structural shielding design, see National Council on Radiation Protection and Measurements Report No. 147 (NCRP-147). Slide 27 HR.01.02.05 The hospital verifies staff qualifications. EP 19: For hospitals that provide computed tomography (CT) services: The hospital verifies and documents that a radiologic technologist who performs CT exams has the following qualifications: Registered by the American Registry of Radiologic Technologists (ARRT) Certified by the ARRT in radiography and/or computed tomography Trained and experienced in operating CT equipment Slide 28 HR.01.02.05 EP 20: For hospitals that provide computed tomography (CT) services: Diagnostic medical physicists that support CT services are board certified in diagnostic radiological physics or radiological physics by the American Board of Radiology, the American Board of Medical Physics, or an equivalent source. If the diagnostic medical physicist is not board certified, then he or she has completed the following: A graduate degree in medical physics, radiologic physics, physics, or another relevant physical science or engineering discipline. Formal coursework in the biological sciences with at least one course in biology or radiation biology, and one course in anatomy, physiology, or a similar topic related to the practice of medical physics Three years of documented experience in a clinical CT environment Slide 29 HR.01.05.03 Staff participate in ongoing education and training. EP 14: For hospitals that provide computed tomography (CT) services: The hospital verifies and documents that radiologic technologists who perform CT examinations participate in ongoing education. Ongoing education must include annual training on radiation dose reduction awareness and techniques following As Low As Reasonably Achievable (ALARA), Image Gently, and Image Wisely concepts. Slide 30 HR.01.05.03 EP 25: Staff providing magnetic resonance imaging (MRI) services participate in education and training on safe practices in the MRI environment including the following: - Patient screening criteria for ferrous-based items - Proper patient positioning activities to avoid burns - Equipment and supplies that have been determined to be safe for use in MRI areas - MRI safety response procedures for patients who require urgent or emergent medical care - MRI equipment emergency shutdown procedures Slide 31 LD.04.04.01 (New Standard) The hospital uses clinical practice guidelines when providing the following diagnostic imaging services: computed tomography, magnetic resonance imaging, positron emission tomography, and nuclear medicine. For Hospitals that use CT, MRI, PET and NM. EP 1: The hospital uses evidence-based guidelines and considers the patients age and previous imaging exams when deciding on the most appropriate type of imaging exam. EP 2: The hospital establishes imaging protocols based on current standards of practice, which address key criteria including, clinical indication, patient age, patient positioning, scan times, radiation dose limits, and contrast administration. Slide 32 LD.04.04.01 EP 3: Imaging protocols are kept current and adjusted with input from an interpreting radiologist, medical physicist, and chief imaging technologist. Imaging protocols are adjusted based on individual patient needs and on changes to standards of practice. Slide 33 MM.06.01.01 The hospital safely administers medications. EP 13: Before administering a radioactive isotope, staff verify that the dose to be administered is within 20% of the prescribed dose, or, if the dose is prescribed as a range, staff verify that the dose to be administered is within the prescribed range. Slide 34 PC.01.02.15 The hospital provides for diagnostic testing. EP 5: The hospital documents in the patients record the radiation dose on every study produced during a CT examination. Note 1: This element of performance is applicable only for systems capable of calculating and displaying radiation doses. Note 2: This element of performance does not apply to systems used for therapeutic radiation treatment planning or delivery, or for calculating attenuation coefficients for nuclear medicine studies. Slide 35 PC.01.02.15 EP 6: For hospitals that provide computed tomography (CT) services: The interpretive report of a diagnostic CT study includes the radiation dose. The dose is either recorded in the patient's interpretive report or included on the protocol page, which is then attached to the interpretive report. (used to apply only to California). EP 7: For hospitals that provide computed tomography (CT) services: The hospital electronically sends each CT study and protocol page that lists the radiation dose and related technical factors to the hospitals electronic picture archiving and communications system (PACS). Slide 36 PC.01.02.15 EP 7: Note: This element of performance is only applicable for systems capable of calculating and displaying radiation doses. EP 10: For hospitals that provide computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), or nuclear medicine (NM) services: Prior to conducting a diagnostic imaging study, the hospital verifies the following: - Correct patient, patient positioning & imaging site - For CT only: Correct imaging protocol - For CT only: Correct scanner parameters Slide 37 PC.01.02.15 EP 11: For hospitals that provide computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), or nuclear medicine (NM) services: The hospital makes certain that imaging studies are based on an order from a licensed independent practitioner or other qualified practitioner in accordance with law and regulation. Slide 38 PI.01.01.01 The hospital collects data to monitor its performance. EP 46: For hospitals that provide computed tomography (CT) services: The hospital collects data on incidents where radiation dose limits identified in imaging protocols have been exceeded. EP 47: For hospitals that provide magnetic resonance imaging (MRI) services: The hospital collects data on patient burns that occur during MRI exams. Slide 39 PI.01.01.01 EP 48: For hospitals that provide magnetic resonance imaging (MRI) services: The hospital collects data on the following: - Incidents when ferrous-based items entered the MRI scanner room. - Injuries resulting from the presence of ferrous-based items in the MRI scanner room. Slide 40 PI.02.01.01 The hospital compiles and analyzes data. EP 6: For hospitals that provide computed tomography (CT) services: The hospital analyzes data on CT radiation doses and compares it with external benchmarks, when available. Slide 41 Some Staggering Statistics.. Slide 42 Slide 43 Slide 44 Slide 45 The Wrong Way to Perform Quality Control See clip from the TV series I Love Lucy Slide 46 Incident Reporting Who: Reports can be filed on patients, physicians, visitors or staff. What: Any incident that compromises or has the potential to compromise safety, including equipment failure can be reported and tracked. When: Reports can be filed anytime 24/7 Where: Reports cover any location on hospital grounds How: Reports can be filed from any available computer terminal in the hospital. *** Reports can be anonymous*** Action : Read by Quality, Risk Management, Director of Area, and can be reviewed by leadership, and appropriate MD leadership Slide 47