j-series chillers kits and accessories product presentation

11
J-series Chillers KITS and ACCESSORIES Product Presentation

Upload: nora-fitzgerald

Post on 23-Dec-2015

229 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: J-series Chillers KITS and ACCESSORIES Product Presentation

J-series Chillers KITS and ACCESSORIES

Product Presentation

Page 2: J-series Chillers KITS and ACCESSORIES Product Presentation

2Apr 19, 2023

Public

New Chiller Accessories

Daikin Name EWAD..AJ EWYD..AJ EWAD..BJ EWAP..AJ EWWD..DJ EWWD..CJ EWWD..BJEKAC200J o o o o o o oEKACBAC o o o o o o oEKACLON o o o o o o oEKCON o o o o o o oEKCONUSB o o o o o o oEKMODEM o o o o o o oEKGSMOD o o o o o o oEKBMSBNJ - - o o o o oEKRUPCJ o o - - - - -EKRUPCK - - o o o o oEKCSCII o o o o o o oEKPV2J o o o o o o oEKBT500N o o o o o o oEKBTC10N o o o o o o oEKBT500C o o o o o o oEKBTC10C o o o o o o o

o = available option

Page 3: J-series Chillers KITS and ACCESSORIES Product Presentation

3Apr 19, 2023

Public

EKAC200J: RS485 Serial Address CardThree different connection possibilities exist: BMS: MODBUS needs an EKAC200J per connected chiller. No gateway. BMS: BACnet PTP (Point to Point) protocol requires an EKAC200J per connected

chiller and an EKBMSBNJ gateway. BACnet PTP is a low level Class 2 BACnet. RS485: All other communication or plant management accessories requiring RS485

or RS232 communication require an EKAC200J per connected chiller.

Unit 1

RS485 Supervisory Network

Unit 2 Unit 3 Unit ..

BACnet PTP (Class 2)

GatewayEKBMSBNJ

Supervisory systemEg: Chiller Sequencing Control EKCSCII

RS485: MODBUS Protocol

EKAC EKAC EKAC

EKAC

KEY

RS485 Serial Address Card EKAC200J

Unit 1

RS485 Supervisory Network

Unit 2 Unit 3 Unit ..

BACnet PTP (Class 2)

GatewayEKBMSBNJ

Supervisory systemEg: Chiller Sequencing Control EKCSCII

RS485: MODBUS Protocol

EKAC EKAC EKAC

EKAC

KEY

RS485 Serial Address Card EKAC200J

Page 4: J-series Chillers KITS and ACCESSORIES Product Presentation

4Apr 19, 2023

Public

EKACBAC

Ethernet Address Card for Class 4 BACnet communication with a BMS system. Each connected chiller requires an Ethernet card. No gateway is needed.

Unit 1 Unit 2 Unit 3 Unit ..

BACnet (Class 4)

EKAC EKAC EKAC

EKAC

KEY

Ethernet Address CardEKACBAC

Unit 1 Unit 2 Unit 3 Unit ..

BACnet (Class 4)

EKAC EKAC EKAC

EKAC

KEY

Ethernet Address CardEKACBAC

Page 5: J-series Chillers KITS and ACCESSORIES Product Presentation

5Apr 19, 2023

Public

EKACLON

LON FTT Address Card for LON communication with a BMS system. The card is supplied preloaded with the respective LON xif chiller profile.

Unit 1 Unit 2 Unit 3 Unit ..

LON Protocol

EKAC EKAC EKAC

EKAC

KEY

LON FTT Address CardEKACLON

Unit 1 Unit 2 Unit 3 Unit ..

LON Protocol

EKAC EKAC EKAC

EKAC

KEY

LON FTT Address CardEKACLON

Page 6: J-series Chillers KITS and ACCESSORIES Product Presentation

6Apr 19, 2023

Public

EKMODEM: Fixed Line Modem for remote monitoring of the chiller plant. A maximum of 32 chillers can be connected to a single modem. The modem communication protocol is RS232 and an EKAC200J and EKCON are necessary.

EKGSMOD: GSM Modem for remote monitoring of the chiller plant. A maximum of 32 chillers can be connected to a single modem. The modem communication protocol is RS232 and an EKAC200J and EKCON are necessary.

Tele-communication

Unit 1

RS232 Supervisory Network

Unit 2 Unit 3 Unit ..

GSM ModemEKGSMOD

Supervisory systemEg: Plant Visor EKPV2J

EKAC EKAC EKAC

EKAC

KEY

RS485 Serial Address Card EKAC200J

EKCON EKCON EKCON

Fixed ModemEKMODEM

EKCON RS485 to RS232 Converter EKCON

Unit 1

RS232 Supervisory Network

Unit 2 Unit 3 Unit ..

GSM ModemEKGSMOD

Supervisory systemEg: Plant Visor EKPV2J

EKAC EKAC EKAC

EKAC

KEY

RS485 Serial Address Card EKAC200J

EKCON EKCON EKCON

Fixed ModemEKMODEM

EKCON RS485 to RS232 Converter EKCON

Page 7: J-series Chillers KITS and ACCESSORIES Product Presentation

7Apr 19, 2023

Public

Remote User Interfaces EKRUPCJ: Remote control interface for EWAD~AJYNN. This interface can be

located upto 500m from the unit.

EKRUPCK: Remote control interface for other ranges. This interface can be located upto 500m from the unit.

Unit 1

pLAN

EKRUPCJ orEKRUPCK

Unit 1

pLAN

EKRUPCJ orEKRUPCK

Page 8: J-series Chillers KITS and ACCESSORIES Product Presentation

8Apr 19, 2023

Public

EKCSCII: Chiller Sequencing Control

Chiller sequencing (Max chillers = 5) Cooling towers sequencing control (Max Towers = 5 each with 2 steps) Chiller sequencing Primary pump control (Max Primary pumps = 1) Secondary pumps control (Max Secondary Pumps = 5, with upto 2 inverter driven) Secondary circuit bypass valve control Chilled water circuit bypass valve control Set point override Demand limit Double set point Unit turnover BMS connectivity (Carel, Modbus, LonWork, BACnet) Remote On/Off

Separate control panel to allow the sequencing of a group of chillers (max 5) as a single plant for optimised power management and energy flow balancing.

Note: See separate EKCSCII presentation

Page 9: J-series Chillers KITS and ACCESSORIES Product Presentation

9Apr 19, 2023

Public

EKPV2J: Plant Visor 2 For local monitoring (PC) of each chiller or remote monitoring via modem (EKMODEM or EKGSMOD) with the PlantVisorTM supervision program.

Compatible with Windows 2000 2nd Edition and Windows XP. Both local and remote monitoring is by RS232 communication.

The main monitoring and control features are: Unit status monitoring Circuit status monitoring Modification of setpoints Display of Alarms

Page 10: J-series Chillers KITS and ACCESSORIES Product Presentation

10Apr 19, 2023

Public

Hydraulic Kits: Buffer Tanks EKBT500N: 500l naked buffer tank on metal base frame. EKBTC10N: 1000l naked buffer tank on metal base frame. EKBT500C: 500l buffer tank with cabinet on metal base frame. EKBTC10C: 1000l buffer tank with cabinet on metal base frame.

Naked Buffer Tank on Base Frame

Plan View

EKBT***C

Buffer Tank with cabinet in RAL7032

EKBT***N

Page 11: J-series Chillers KITS and ACCESSORIES Product Presentation

11Apr 19, 2023

Public

Engineered for flexibility and performance.™