IUCA- IMECOR CATO 2006

CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

Page 2: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

FUNCION CORAZON

•bombear sangre en el sistema circulatorio

SISTEMA CIRCULATORIO

* doble

* completo

* cerrado

IUCA- IMECOR CATO 2006

Page 3: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

TRATAMIENTO INSUFICIENCIA CARDIACA TERMINAL

(Clase funcional IV de la NYHA)

- Transplante Cardíaco

- Corazón Artificial

IUCA- IMECOR CATO 2006

Page 4: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

IUCA- IMECOR CATO 2006

Page 5: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

REQUISITOS DE COMPATIBILIDAD- Compatibilidad Anatómica:

* Respeto dimensiones cavidad pericárdica* Respeto y alineamiento puntos conexión anastomóticos - flujos

entrada y salida- Compatibilidad Hemodinámica:

* manejo volumen sangre cada latido y por minuto hacia circuitos pulmonar y sistémico

* manejo variación retorno “shunt pulmonar”- Compatibilidad Hematológica:

* trombosis* hemólisis* “stress” sanguíneo* sangrados* coagulopatías

- Compatibilidad Biológica: * piel cerrada* infecciones * tranquilidad física y síquica del paciente* biocompatibilidad de materiales

IUCA- IMECOR CATO 2006

Page 6: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

PROYECTO CATO

1. ETAPA DE DESARROLLO CIENTIFICO Y RESPALDO LEGAL Fase 1 – Invención: concepción médica y de ingeniería Fase 2 – Registro de las Patentes Fase 3 – Divulgación y Apoyo científico de la Invención Fase 4 – Formación del Instituto Uruguayo del Corazón Artificial, IUCA Fase 5 – Formación de IMECOR S.A.

2. ETAPA DE INVESTIGACION Y DESARROLLO EXPERIMENTAL. Fase 1 - “in vitro”: Prototipo de Laboratorio Fase 2 - “in vivo”: A - Implantación Animal “en agudo” B - Implantación Animal “en crónico”

3. ETAPA DE IMPLANTACION EN UN SER HUMANO

4. ETAPA DE PRODUCCION INDUSTRIAL

IUCA- IMECOR CATO 2006

Page 7: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

EQUIPO TÉCNICO CIENTÍFICO

Dr. Juan M. Giambruno Maroño, Cirujano Cardiaco Ing. Industrial Gonzalo Escobar Abal Ing. Electrónico Hugo ArticardiIng. Electrónico Ernesto AchkarIng. Electrónico Juan Piaggio MazzaraIng. Químico Jaime VilizzioIng. Químico Daniel Mosca AcostaDr. Prof. Héctor Estable, Cirujano CardiacoDr. Rafael Anzibar, Cirujano CardiacoDra. Mónica Giambruno, CardiólogaDr. Héctor Cardelino, Médico. Empresario Dr. Prof. Pedro Lorenzi, Médico VeterinarioDr. Alejandro Benech, Médico VeterinarioDr. José Antonio Villamil (Asesoramiento Patentes -

DNPI)Dra. María Paz Wilson Chans, AbogadaT.M. Daniel Capote

IUCA- IMECOR CATO 2006

Page 8: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

IUCA- IMECOR CATO 2006

Page 9: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

IUCA- IMECOR CATO 2006

Page 10: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

IUCA- IMECOR CATO 2006

Page 11: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO
Page 12: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO
Page 13: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

CATO - Respuesta autónoma

IUCA- IMECOR CATO 2006

Page 14: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

IUCA- IMECOR CATO 2006

Page 15: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

IUCA- IMECOR CATO 2006

Page 16: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

LABIU- Circuito Simulador Hemodinámico

IUCA- IMECOR CATO 2006

Page 17: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

IUCA- IMECOR CATO 2006

Page 18: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

NIVEL alfa V1 V2,V3 T1 f VES GC

3-0 500 5500 0 40 30 80 2.400

6 1000 6500 1500 45 60 80 4.800

7 1200 6500 2500 50 70 80 5.600

8 1500 6500 3000 50 80 80 6.400

9 2000 6900 3300 50 90 80 7.200

10 2600 7000 3300 50 100 80 8.000

11 3000 7200 3700 50 110 80 8.800

12 3000 7300 3900 50 120 80 9.600

Cúpula Ternero 12.2 (PARETO A)

CDV lámpara chica, PC14

BAS A 30/2 - 2 álabes

BL 35/64 K 1155

H2O destilada 600 ml aprox

Nicchio 7.21CD 80 XG

CI 150 M

4 Válvulas Hancock 29

Conectores rápidos, adaptados para tubo

Circuito en serie

PVC = 6  PAI =

9

PPD = 20   PAD = 80

CATO – Controlabilidad hemodinámica

IUCA- IMECOR CATO 2006

Page 19: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

CATO - SENSIBILIDAD A LA PRECARGA IZQUIERDA

PAI = 9 PAI = 18

NIVEL alfa V1 f VEI GC VEI GC

6 1000 6300 60 88 5.280 95 5.700

7 1200 6600 70 87 6.090 92 6.450

8 1500 6900 80 83 6.640 93 7.400

9 2200 7000 90 87 7.830 91 8.150

10 3000 7100 100 77 7.700 86 8.600

11 3000 7500 110 83 9.130 85 9.400

12 3000 7800 120 83 9.960 84 10.100

IUCA- IMECOR CATO 2006

Page 20: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

SENSIBILIDAD A LA PRECARGA IZQUIERDA

3.000

4.000

5.000

6.000

7.000

8.000

9.000

10.000

11.000

60 70 80 90 100 110 120

FRECUENCIA

GA

ST

O C

AM

AR

A IZ

Q. (

ml)

PAI = 18

PAI = 9

IUCA- IMECOR CATO 2006

Page 21: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

Experimentación “in vivo” - Protocolos de Implante

para prototipos de diferentes características

de diferente localización de implantación

de diferente procedimiento y método quirúrgico

de diferente manejo postoperatorio

IUCA- IMECOR CATO 2006

Page 22: IUCA- IMECOR CATO2006 CORAZÓN ARTIFICIAL TOTAL ORTOTÓPICO

IUCA- IMECOR CATO 2006