ista 6 - amazon.com sioc - b received date: feb 27,2019 ... · lab test request {filled out by...
TRANSCRIPT
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 5/9/2018
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 1 of 11
Bureau Veritas Consumer Products Services Division (Shanghai) No.168, Guanghua Road, Zhuanqiao Town, Minhang, Shanghai, China, 201108 Tel: 86-21-24166888, Fax: 86-21-64891984 Email: [email protected] website:cps.bureauveritas.com
This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or
for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the
test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken
or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the
information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify
us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall
specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this
report, the tests conducted and the correctness of the report contents.
ITEM INFORMATION
Vendor/Seller Name: MOXY INVESTMENT LIMITED
ASIN: B07HGVFHYR
Item: /
UPC: /
Certification Passed: Pass: Tier 1- Frustration Free Packaging (FFP) Pass: Tier 2- Ships In Own Container (SIOC)
Fail: Tier 3- Enforced Over Box (EOB)
LAB INFORMATION
Testing Lab: BUREAU VERITAS CONSUMER PRODUCTS SERVISE SH CO., LTD
Location: SHANGHAI, CHINA
Date of Test: 3/1/2019
ISTA Member/ Lab Tech: ST-2325/ JARED JI
TEST RESULTS
Tested Item Summary
Number of Samples Tested Number of Samples Passed Number of Samples Failed
1 1 NO
Corrugate Board Strength BST: 385 lbs/in2 / ECT: 75.2 lbs/in
EPS DENSITY
Part Component Dimensions (in.) Weight Density (kg/m3)
/ / / / /
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 4/24/17
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 2 of 11
Post Test Comments:
Overview
THE SAMPLE WAS NO DAMAGE NOTED AFTER SIOC TYPE B TESTING
Product Condition
NO DAMAGE NOTED
Packaging Condition
NO DAMAGE NOTED
LAB TEST REQUEST {filled out by requestor}
Test Requestor /
Project Name /
Submission Date FEB 27,2019
Due Date MAR 04,2019
ASIN Manufacturer Description
B07HGVFHYR UE FURNITURE CO., LTD.
STACK CHAIR (MODEL: XDD1Q)
Package Dimension 81.5*56*68 cm / 32-3/8 x 22-1/4 x 27 in.
Package Weight 34.2 KG / 74.2 lbs.
Classification 1 SIOC
Classification 2 Parcel
Test Type ISTA 6 –Amazon.com SIOC - B
Value Add Packaging (VAP)
No
Value Add Packaging (VAP) Info
MASTER CARTON: Corrugated board, Polybag, Foam sheet, plastic bubble sheet, cable tie
Total Test Samples 1 MASTER CARTON
Additional Notes N/A
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 4/24/17
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 3 of 11
PRE-TEST INSPECTION {filled out by lab}
Product Condition Package was not opened before testing to review product.
Package Condition NO DAMAGE NOTED
Package Condition before testing
☒ ORIGINAL as arrived in the lab for testing
☐ NEW re-packaged with new materials before testing
Corrugated Info (Box Cert if available)
Double wall corrugated board
Dunnage Info NA
Additional Notes NA
PRE-TEST PICTURES
Six sides of the ASIN package should be numbered and photographed. If a box cert is present it should be taken and recorded.
Isometric picture views should be taken as called out below. Pictures of special call outs and or damage should have description
of location and detailed information in the text box below the picture.
Side 1 Side 2 Side 3
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 4/24/17
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 4 of 11
PRE-TEST PICTURES {continued}
Side 4 Side 5 Side 6
ISO #1 Side 1/2/5 ISO #2 Sides 3/4/6
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 4/24/17
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 5 of 11
TEST DETAIL
Items in black were completed and values updated. Items left in gray were not completed.
Test Value P/F P/F P/F P/F P/F OBSERVATIONS
BLOCK 1:Temp and Humidity 23ºC and 48% RH
P
Ambient Lab Temp 12+ hours
BLOCK 2: Drop 1-7 18 INCHES P NA NA NA NA NO DAMAGE NOTED
BLOCK 2: Drop 8 36 INCHES P NA NA NA NA NO DAMAGE NOTED
BLOCK 2: Drop 9 18 INCHES P NA NA NA NA NO DAMAGE NOTED
BLOCK 3: Tip/Tip Over NA NA NA NA NA NA NA
BLOCK 9: Compression
Face 3: 965 Lbs / 1 hour.
P NA NA NA NA
NO DAMAGE NOTED
BLOCK 10: Clamping Simulation
Face 5-6: 297 Lbs.
Face 2-4: 297 Lbs.
P NA NA NA NA
NO DAMAGE NOTED
BLOCK 12: Vib with Top Load Face 3 265 Lbs. P NA NA NA NA
NO DAMAGE NOTED
BLOCK 12: Vib with Top Load Face 4 205 Lbs. P NA NA NA NA
NO DAMAGE NOTED
BLOCK 12: Vib with Top Load Face 6 160 Lbs. P NA NA NA NA
NO DAMAGE NOTED
BLOCK 12: Vib Face 3 (Pick-Up Truck) 0 Lbs. P NA NA NA NA
NO DAMAGE NOTED
BLOCK 15: Drop 10-15 18 INCHES P NA NA NA NA NO DAMAGE NOTED
BLOCK 15: Drop 16 36 INCHES P NA NA NA NA NO DAMAGE NOTED
BLOCK 15: Drop 17 18 INCHES P NA NA NA NA NO DAMAGE NOTED
BLOCK 21: Rotational Edge Drop NA NA NA NA NA NA NA
BLOCK 22: Full Rotational Flat Drop NA NA NA NA NA NA NA
BLOCK 23: Bridge Impact NA NA NA NA NA NA NA
BLOCK 24: Concentrated Edge Impact NA NA NA NA NA NA NA
BLOCK 25: Leak Test NA NA NA NA NA NA NA
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 5/9/2018
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 6 of 11
TEST PICTURES
Pictures should be taken of each block test set up along with a post picture taken of the item at the end of each test block.
Additional pictures of damage should have locations noted, size of damages measured, and written in text box below them.
Block 2 Test Set Up Block 2 Post Test Item Picture
Block 2 Test Set Up Block 2 Post Test Item Picture
Block 2 Test Set Up Block 2 Post Test Item Picture
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 5/9/2018
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 7 of 11
TEST PICTURES {continued}
Block 9 Test Set Up Block 9 Post Test Item Picture
Block 10 Test Set Up Block 10 Post Test Item Picture
TEST PICTURES {continued}
Block 12 Face 3 Test Set up Block 12 Face 3 Post Test Item Picture Block 12 Face 3 Test Vibration Profile
Block 12 Face 4 Test Set up Block 12 Face 4 Post Test Item Picture Block 12 Face 4 Test Vibration Profile
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 5/9/2018
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 8 of 11
Block 12 Face 6 Test Set up Block 12 Face 6 Post Test Item Picture Block 12 Face 6 Test Vibration Profile
TEST PICTURES {continued}
Block 12 Face 3 (Pick-Up) Test Set up Block 12 Face 3 Post Test Item Picture Block 12 Face 3 Test Vibration Profile
Block 15 Test Set Up Block 15 Post Test Item Picture
Block 15 Test Set Up Block 15 Post Test Item Picture
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 5/9/2018
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 9 of 11
Block 15 Test Set Up Block 15 Post Test Item Picture
POST TEST PICTURES
Isometric views of the box should be taken as called out in first two picture spots. An exploded bill of materials (BOM) view
should be added to the third slot. Additional pictures of damage should have locations noted, size of damages measured, and
written in text box below them.
ISO #1 Side 1/2/5 ISO #2 Sides 3/4/6 Exploded BOM View
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 5/9/2018
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 10 of 11
POST TEST PICTURES {continued}
Packaging photo 1 Packaging photo 2 Packaging photo 3
Packaging photo 4 Packaging photo 5 Packaging photo 6
ISTA 6 - Amazon.com – SIOC - B Test Report_External
VERSION DATE: 5/9/2018
(6619)057-1063 Received Date: FEB 27,2019 Report Date: MAR 04,2019
Page 11 of 11
BVCPS (SHANGHAI) GENERAL CONTACT INFORMATION FOR THIS REPORT
TELEPHONE NO
E-MAIL:
86-21-24166888
BUREAU VERITAS
CONSUMER PRODUCTS SERVICE DIVISION (SHANGHAI)
Laboratory Test location: No. 368, Guangzhong Road, Zhuanqiao Town, Minhang,
Shanghai.
No. 168, Guanghua Road, Zhuanqiao Town, Minhang, Shanghai.
JARED JI
SUPERVISOR (HARDLINE DIVISION)
END OF REPORT