isometric view - hse utilities · 2019-03-12 · isometric view top view ... 6" plain end pipe...

1
SECTION "A-A" OUTLET END VIEW ISOMETRIC VIEW TOP VIEW SCHIER MODEL NUMBER SV24-O6 A A TOP VIEW ISOMETRIC VIEW OUTLET END VIEW SECTION "A-A" FLOW SCHIER MODEL NUMBER GB-250 INLET A A C L TOP VIEW

Upload: others

Post on 13-Mar-2020

15 views

Category:

Documents


0 download

TRANSCRIPT

SECTION "A-A" OUTLET END VIEW

ISOMETRIC VIEW

TOP VIEW

SCHIER MODEL NUMBER SV24-O6

AA

TOP VIEW ISOMETRIC VIEW

OUTLET END VIEW

SECTION "A-A"

FLOW

SCHIER MODEL NUMBER GB-250

INLET

AA

C

L

TOP VIEW

AutoCAD SHX Text
REVISED 3/7/2019
AutoCAD SHX Text
CHANGED 4" to 6" ON SPEC NOTE 1. FOR 100 GPM POLYETHELNE GREASE INTERCEPTOR DETAIL
AutoCAD SHX Text
3/7/2019
AutoCAD SHX Text
2
AutoCAD SHX Text
WHF
AutoCAD SHX Text
TK
AutoCAD SHX Text
UPDATED EXTERIOR INTERCEPTOR/SEPARATOR DETAIL FROM McCREARY
AutoCAD SHX Text
DISCLAIMER
AutoCAD SHX Text
HSE'S GRINDER PUMP DETAILS, GREASE INTERCEPTOR AND SMALL DIAMETER
AutoCAD SHX Text
FORCE MAIN SPECIFICATIONS ARE COMPLEMENTARY IN NATURE AND SHOULD NOT
AutoCAD SHX Text
BE INTERPRETED INDIVIDUALLY WITHOUT REFERENCE TO THE OTHER SHEETS.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
CONTRACTOR SHALL CONTACT ENGINEER
AutoCAD SHX Text
THIS PROJECT TO VERIFY PROPER INTERPRETATION
AutoCAD SHX Text
OF SPECIFICATIONS AND CONSTRUCTION PLANS.
AutoCAD SHX Text
11905 LAKESIDE DRIVE
AutoCAD SHX Text
FISHERS, INDIANA 46038
AutoCAD SHX Text
ENGINEER%%U
AutoCAD SHX Text
PRIOR TO PURCHASING ANY EQUIPMENT FOR
AutoCAD SHX Text
(317) 577-1150
AutoCAD SHX Text
SAMCO
AutoCAD SHX Text
c
AutoCAD SHX Text
THESE DRAWINGS AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SANITARY MANAGEMENT & ENGINEERING COMPANY, INC. AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF SANITARY MANAGEMENT & ENGINEERING COMPANY, INC.
AutoCAD SHX Text
2019 BY SANITARY MANAGEMENT & ENGINEERING COMPANY, INC.
AutoCAD SHX Text
GREASE INTERCEPTOR SANITARY SEWER DETAILS
AutoCAD SHX Text
N/A
AutoCAD SHX Text
-
AutoCAD SHX Text
Hamilton Southeastern Utilities, INC.
AutoCAD SHX Text
-
AutoCAD SHX Text
UPDATED FOR 2017
AutoCAD SHX Text
12/15/2017
AutoCAD SHX Text
317-577-1150 Fax 317-577-3642
AutoCAD SHX Text
FISHERS, INDIANA 46038
AutoCAD SHX Text
11905 Lakeside Drive
AutoCAD SHX Text
CERTIFIED
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
TITLE
AutoCAD SHX Text
PREPARED FOR
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
NO.
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
CHECK
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
Sanitary Management &
AutoCAD SHX Text
Engineering Company, Inc.
AutoCAD SHX Text
1
AutoCAD SHX Text
WHF
AutoCAD SHX Text
TK
AutoCAD SHX Text
SPECIFICATIONS
AutoCAD SHX Text
4" INLET/OUTLET SCH. 40. PLAIN END (NO-HUB)
AutoCAD SHX Text
1.
AutoCAD SHX Text
MAX FLOW RATE: 100 GPM
AutoCAD SHX Text
2.
AutoCAD SHX Text
LIQUID CAPACITY: 275 GALLONS
AutoCAD SHX Text
3.
AutoCAD SHX Text
MAX GREASE CAPACITY: 1,076 LBS. (147.4 GALLONS)
AutoCAD SHX Text
4.
AutoCAD SHX Text
MAX SOLIDS/SEDIMENT CAPACITY: 105 GALLONS
AutoCAD SHX Text
5.
AutoCAD SHX Text
UNIT WEIGHT W/STD. COVERS: 230 LBS.
AutoCAD SHX Text
6.
AutoCAD SHX Text
MAXIMUM OPERATING TEMPERATURE 190° CONTINUOUS.
AutoCAD SHX Text
7.
AutoCAD SHX Text
HIGHWAY RATED COVER: 16,000 LB. CAPACITY (STANDARD)
AutoCAD SHX Text
8.
AutoCAD SHX Text
SEAMLESS MOLDED POLYETHYLENE TANK.
AutoCAD SHX Text
9.
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
LISTED BY IAPMO TO ASME GREASE INTERCEPTOR
AutoCAD SHX Text
1.
AutoCAD SHX Text
STANDARD #A112.14.3 AND CSA B481.1
AutoCAD SHX Text
FACTORY INSTALLED BUILT-IN FLOW CONTROL.
AutoCAD SHX Text
2.
AutoCAD SHX Text
FOR GRAVITY DRAINAGE APPLICATIONS ONLY.
AutoCAD SHX Text
3.
AutoCAD SHX Text
DO NOT USE FOR PRESSURE APPLICATIONS.
AutoCAD SHX Text
SEAMLESS HIGH DENSITY POLYETHYLENE TANK.
AutoCAD SHX Text
4.
AutoCAD SHX Text
UNIT SUPPLIED WITH BUILT-IN ADAPTER(S) FOR UP TO 6" OF
AutoCAD SHX Text
5.
AutoCAD SHX Text
ADJUSTABILITY. ADDITIONAL RISER(S) AVAILABLE FOR DEEPER
AutoCAD SHX Text
BURIAL DEPTH.
AutoCAD SHX Text
COVER PLACEMENT ALLOWS FULL ACCESS TO TANK
AutoCAD SHX Text
6.
AutoCAD SHX Text
FOR PROPER MAINTENANCE.
AutoCAD SHX Text
VENT NOT REQUIRED UNLESS PER LOCAL CODE.
AutoCAD SHX Text
7.
AutoCAD SHX Text
NARROW FOOTPRINT ALLOWS CLEARANCE THROUGH DOORWAYS
AutoCAD SHX Text
8.
AutoCAD SHX Text
AND DOWN STAIRWELLS.
AutoCAD SHX Text
ENGINEERED INLET AND OUTLET DIFFUSERS ARE REMOVABLE TO
AutoCAD SHX Text
9.
AutoCAD SHX Text
INSPECT/CLEAN PIPING.
AutoCAD SHX Text
FOR ON-THE-FLOOR OR BURIED APPLICATIONS.
AutoCAD SHX Text
10.
AutoCAD SHX Text
INTEGRAL AIR RELIEF / ANTI-SIPHON / SAMPLING ACCESS.
AutoCAD SHX Text
11.
AutoCAD SHX Text
THREE OUTLET OPTIONS FOR EASY ROUGH IN. UNIT SHIPPED WITH
AutoCAD SHX Text
12.
AutoCAD SHX Text
OUTLET DIFFUSER IN OUTLET "B".
AutoCAD SHX Text
DIFFUSION FLOW TECHNOLOGY
AutoCAD SHX Text
THE INLET DIFFUSER SPLITS INCOMING EFFLUENT INTO TWO PATHS
AutoCAD SHX Text
THAT UTILIZE THE ENTIRE LIQUID VOLUME OF THE TANK FOR EFFICIENT
AutoCAD SHX Text
GREASE SEPARATION. THE CALIBRATED OPENINGS GREATLY REDUCE
AutoCAD SHX Text
EFFLUENT TURBULENCE. THE EFFLUENT ENTERS THE MAIN CHAMBER
AutoCAD SHX Text
WITHOUT DISTURBING THE EXISTING GREASE OR SEDIMENT LAYERS.
AutoCAD SHX Text
THE INTEGRAL AIR RELIEF / ANTI-SIPHON IN THE TOP OF THE OUTLET DIFFUSER
AutoCAD SHX Text
ALLOWS PRESSURE STABILIZATION WITHIN THE UNIT DURING OPERATION.
AutoCAD SHX Text
THE BOTTOM OF THE OUTLET DIFFUSER ALLOWS ONLY EFFLUENT WHICH IS FREE OF
AutoCAD SHX Text
GREASE TO EXIT THE TANK. IT CAN EASILY BE ATTACHED TO ANY
AutoCAD SHX Text
OF THE THREE OUTLETS PROVIDED TO EASE JOBSITE PIPING LAYOUTS.
AutoCAD SHX Text
OPTIONS:
AutoCAD SHX Text
H20 RATED CAST IRON COVER: 20,000LB CAPACITY
AutoCAD SHX Text
PEDESTRIAN RATED COVER: 2,000 LB. CAPACITY
AutoCAD SHX Text
TELEGLIDE FIELD ADJUSTABLE RISERS FOR EXTENDING COVERS TO GRADE
AutoCAD SHX Text
MALE PIPE THREAD CONNECTIONS
AutoCAD SHX Text
6" PLAIN END PIPE CONNECTIONS (INLET/OUTLET "B" ONLY)
AutoCAD SHX Text
HIGH WATER ANCHOR KIT
AutoCAD SHX Text
CLAMPING COLLAR KIT
AutoCAD SHX Text
ENGINEER SPECIFICATION GUIDE
AutoCAD SHX Text
SCHIER GREAT BASIN GREASE INTERCEPTOR MODEL # GB-250 SHALL GREASE INTERCEPTOR MODEL # GB-250 SHALL
AutoCAD SHX Text
BE LIFETIME GUARANTEED AND MADE IN USA OF SEAMLESS, ROTATIONALLY-
AutoCAD SHX Text
MOLDED HIGH DENSITY POLYETHYLENE. INTERCEPTOR SHALL BE FURNISHED FOR
AutoCAD SHX Text
ABOVE OR BELOW GRADE INSTALLATION. INTERCEPTOR SHALL BE CERTIFIED TO
AutoCAD SHX Text
ASME A112.14.3 (TYPE C) AND CSA B481.1, WITH FIELD ADJUSTABLE
AutoCAD SHX Text
RISER SYSTEM, BUILT-IN FLOW CONTROL, BUILT-IN TEST CAPS AND THREE OUTLET
AutoCAD SHX Text
OPTIONS. INTERCEPTOR FLOW RATE SHALL BE 100 GPM. INTERCEPTOR GREASE
AutoCAD SHX Text
CAPACITY SHALL BE 1,076 LBS. COVER SHALL PROVIDE WATER/GAS-TIGHT SEAL
AutoCAD SHX Text
AND HAVE MINIMUM 2,000 LBS. LOAD CAPACITY.
AutoCAD SHX Text
ADJUSTABLE ADAPTER
AutoCAD SHX Text
12"
AutoCAD SHX Text
1'-4"
AutoCAD SHX Text
2'-4"
AutoCAD SHX Text
1'-8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
1'-7"
AutoCAD SHX Text
2'-1"
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
%%USPECIFICATIONS
AutoCAD SHX Text
6" INLET/OUTLET SCH. 40. PLAIN END (NO-HUB)
AutoCAD SHX Text
1.
AutoCAD SHX Text
MAX FLOW RATE: 100 GPM
AutoCAD SHX Text
2.
AutoCAD SHX Text
LIQUID CAPACITY: 275 GALLONS
AutoCAD SHX Text
3.
AutoCAD SHX Text
MAX GREASE CAPACITY: 1,076 LBS. (147.4 GALLONS)
AutoCAD SHX Text
4.
AutoCAD SHX Text
MAX SOLIDS/SEDIMENT CAPACITY: 105 GALLONS
AutoCAD SHX Text
5.
AutoCAD SHX Text
UNIT WEIGHT W/STD. COVERS: 230 LBS.
AutoCAD SHX Text
6.
AutoCAD SHX Text
MAXIMUM OPERATING TEMPERATURE 190° F CONTINUOUS.
AutoCAD SHX Text
°
AutoCAD SHX Text
7.
AutoCAD SHX Text
HIGHWAY RATED COVER: 16,000 LB. CAPACITY (STANDARD)
AutoCAD SHX Text
8.
AutoCAD SHX Text
SEAMLESS MOLDED POLYETHYLENE TANK.
AutoCAD SHX Text
9.
AutoCAD SHX Text
%%UNOTES
AutoCAD SHX Text
LISTED BY IAPMO TO ASME GREASE INTERCEPTOR
AutoCAD SHX Text
1.
AutoCAD SHX Text
STANDARD #A112.14.3 AND CSA B481.1
AutoCAD SHX Text
FACTORY INSTALLED BUILT-IN FLOW CONTROL.
AutoCAD SHX Text
2.
AutoCAD SHX Text
FOR GRAVITY DRAINAGE APPLICATIONS ONLY.
AutoCAD SHX Text
3.
AutoCAD SHX Text
DO NOT USE FOR PRESSURE APPLICATIONS.
AutoCAD SHX Text
SEAMLESS HIGH DENSITY POLYETHYLENE TANK.
AutoCAD SHX Text
4.
AutoCAD SHX Text
UNIT SUPPLIED WITH BUILT-IN ADAPTER(S) FOR UP TO 6" OF
AutoCAD SHX Text
5.
AutoCAD SHX Text
ADJUSTABILITY. ADDITIONAL RISER(S) AVAILABLE FOR DEEPER
AutoCAD SHX Text
BURIAL DEPTH.
AutoCAD SHX Text
COVER PLACEMENT ALLOWS FULL ACCESS TO TANK
AutoCAD SHX Text
6.
AutoCAD SHX Text
FOR PROPER MAINTENANCE.
AutoCAD SHX Text
VENT NOT REQUIRED UNLESS PER LOCAL CODE.
AutoCAD SHX Text
7.
AutoCAD SHX Text
NARROW FOOTPRINT ALLOWS CLEARANCE THROUGH DOORWAYS
AutoCAD SHX Text
8.
AutoCAD SHX Text
AND DOWN STAIRWELLS.
AutoCAD SHX Text
ENGINEERED INLET AND OUTLET DIFFUSERS ARE REMOVABLE TO
AutoCAD SHX Text
9.
AutoCAD SHX Text
INSPECT/CLEAN PIPING.
AutoCAD SHX Text
FOR ON-THE-FLOOR OR BURIED APPLICATIONS.
AutoCAD SHX Text
10.
AutoCAD SHX Text
INTEGRAL AIR RELIEF / ANTI-SIPHON / SAMPLING ACCESS.
AutoCAD SHX Text
11.
AutoCAD SHX Text
THREE OUTLET OPTIONS FOR EASY ROUGH IN. UNIT SHIPPED WITH
AutoCAD SHX Text
12.
AutoCAD SHX Text
OUTLET DIFFUSER IN OUTLET "B".
AutoCAD SHX Text
%%UDIFFUSION FLOW TECHNOLOGY
AutoCAD SHX Text
THE INLET DIFFUSER SPLITS INCOMING EFFLUENT INTO TWO PATHS
AutoCAD SHX Text
THAT UTILIZE THE ENTIRE LIQUID VOLUME OF THE TANK FOR EFFICIENT
AutoCAD SHX Text
GREASE SEPARATION. THE CALIBRATED OPENINGS GREATLY REDUCE
AutoCAD SHX Text
EFFLUENT TURBULENCE. THE EFFLUENT ENTERS THE MAIN CHAMBER
AutoCAD SHX Text
WITHOUT DISTURBING THE EXISTING GREASE OR SEDIMENT LAYERS.
AutoCAD SHX Text
THE INTEGRAL AIR RELIEF / ANTI-SIPHON IN THE TOP OF THE OUTLET DIFFUSER
AutoCAD SHX Text
ALLOWS PRESSURE STABILIZATION WITHIN THE UNIT DURING OPERATION.
AutoCAD SHX Text
THE BOTTOM OF THE OUTLET DIFFUSER ALLOWS ONLY EFFLUENT WHICH IS FREE OF
AutoCAD SHX Text
GREASE TO EXIT THE TANK. IT CAN EASILY BE ATTACHED TO ANY
AutoCAD SHX Text
OF THE THREE OUTLETS PROVIDED TO EASE JOBSITE PIPING LAYOUTS.
AutoCAD SHX Text
%%UOPTIONS:
AutoCAD SHX Text
H20 RATED CAST IRON COVER: 20,000LB CAPACITY
AutoCAD SHX Text
PEDESTRIAN RATED COVER: 2,000 LB. CAPACITY
AutoCAD SHX Text
TELEGLIDE FIELD ADJUSTABLE RISERS FOR EXTENDING COVERS TO GRADE
AutoCAD SHX Text
MALE PIPE THREAD CONNECTIONS
AutoCAD SHX Text
6" PLAIN END PIPE CONNECTIONS (INLET/OUTLET "B" ONLY)
AutoCAD SHX Text
HIGH WATER ANCHOR KIT
AutoCAD SHX Text
CLAMPING COLLAR KIT
AutoCAD SHX Text
%%UENGINEER SPECIFICATION GUIDE
AutoCAD SHX Text
SCHIER GREAT BASIN
AutoCAD SHX Text
GREASE INTERCEPTOR MODEL # GB-250 SHALL
AutoCAD SHX Text
BE LIFETIME GUARANTEED AND MADE IN USA OF SEAMLESS, ROTATIONALLY-
AutoCAD SHX Text
MOLDED HIGH DENSITY POLYETHYLENE. INTERCEPTOR SHALL BE FURNISHED FOR
AutoCAD SHX Text
ABOVE OR BELOW GRADE INSTALLATION. INTERCEPTOR SHALL BE CERTIFIED TO
AutoCAD SHX Text
ASME A112.14.3 (TYPE C) AND CSA B481.1, WITH FIELD ADJUSTABLE
AutoCAD SHX Text
RISER SYSTEM, BUILT-IN FLOW CONTROL, BUILT-IN TEST CAPS AND THREE OUTLET
AutoCAD SHX Text
OPTIONS. INTERCEPTOR FLOW RATE SHALL BE 100 GPM. INTERCEPTOR GREASE
AutoCAD SHX Text
CAPACITY SHALL BE 1,076 LBS. COVER SHALL PROVIDE WATER/GAS-TIGHT SEAL
AutoCAD SHX Text
AND HAVE MINIMUM 2,000 LBS. LOAD CAPACITY.
AutoCAD SHX Text
ADJUSTABLE
AutoCAD SHX Text
ADAPTER
AutoCAD SHX Text
100 GPM POLYETHYLENE GREASE INTERCEPTOR
AutoCAD SHX Text
68"
AutoCAD SHX Text
16"
AutoCAD SHX Text
33"
AutoCAD SHX Text
OUTLET "B"
AutoCAD SHX Text
(STANDARD)
AutoCAD SHX Text
OUTLET "A"
AutoCAD SHX Text
(OPTIONAL)
AutoCAD SHX Text
OUTLET "C"
AutoCAD SHX Text
(OPTIONAL)
AutoCAD SHX Text
TIE-DOWN POINT
AutoCAD SHX Text
FOR ANCHOR KIT.
AutoCAD SHX Text
33"
AutoCAD SHX Text
51 "12"
AutoCAD SHX Text
24"TYP
AutoCAD SHX Text
38"
AutoCAD SHX Text
13 "12"
AutoCAD SHX Text
35
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
"
AutoCAD SHX Text
INVERT
AutoCAD SHX Text
SEE NOTE #11
AutoCAD SHX Text
OF INLET
AutoCAD SHX Text
& OUTLET
AutoCAD SHX Text
ENGINEERED INLET AND
AutoCAD SHX Text
OUTLET DIFFUSER
AutoCAD SHX Text
(SEE DESCRIPTION)
AutoCAD SHX Text
SEWER VIEWER POLYETHYLENE WASTEWATER SAMPLING PORT
AutoCAD SHX Text
OUTLET AND INLET
AutoCAD SHX Text
DIFFUSER W/
AutoCAD SHX Text
INSPECTION PORT
AutoCAD SHX Text
STATIC WATER
AutoCAD SHX Text
LINE
AutoCAD SHX Text
T
AutoCAD SHX Text
M
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
OF ANY PAVED OR CONCRETE SURFACES.
AutoCAD SHX Text
HAMILTON SOUTHEASTERN UTILITIES, INC.
AutoCAD SHX Text
HEAVY DUTY SOLID
AutoCAD SHX Text
MANHOLE CASTING TABLE
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
OWNERSHIP
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
(4) 3/8" x 3" STAINLESS STEEL
AutoCAD SHX Text
(SLOPE AWAY FROM CASTING)
AutoCAD SHX Text
COMPOSITE FRAME AND COVER
AutoCAD SHX Text
LETTERING
AutoCAD SHX Text
(SEE MANHOLE CASTING
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
PRIVATE
AutoCAD SHX Text
TABLE FOR DETAILS)
AutoCAD SHX Text
ANCHOR BOLTS (TYPICAL)
AutoCAD SHX Text
(TYPICAL)
AutoCAD SHX Text
2'-0" DIAMETER
AutoCAD SHX Text
BE WITHIN ONE (1) FOOT HORIZONTAL DISTANCE
AutoCAD SHX Text
UNLESS APPROVED BY HSE, CASTINGS MUST NOT
AutoCAD SHX Text
0.20 FEET MINIMUM ABOVE FINISHED GRADE.
AutoCAD SHX Text
TOP OF CASTING SHALL EXTEND
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
GASKET PLUS 1/2" OR 3/4" HAMILTON SOUTHEASTERN UTILITIES, INC. APPROVED
AutoCAD SHX Text
TYPICAL CONCRETE WASTEWATER SAMPLING STRUCTURE
AutoCAD SHX Text
INFLUENT
AutoCAD SHX Text
"SANITARY SEWER - HSE"
AutoCAD SHX Text
RUBBER SLEEVE OF INFI-SHEILD GATOR WRAP AS MANUFACTURED
AutoCAD SHX Text
COMPOSITION AND THICKNESS OF MATERIAL SHALL BE DEPENDENT ON SEASON OF
AutoCAD SHX Text
FLEXIBLE BUTYL RESIN CONCRETE SEALANT (ROPE) CONFORMING TO ASTM C 990.
AutoCAD SHX Text
EACH MANHOLE SECTION SHALL BE SEALED WITH AN EXTERNAL
AutoCAD SHX Text
HEAVY DUTY SOLID
AutoCAD SHX Text
INSTALLATION AND AS DIRECTED BY ENGINEER. CONTRACTOR SHALL GROUT ALL
AutoCAD SHX Text
18" INCHES OR MORE ABOVE
AutoCAD SHX Text
EFFLUENT
AutoCAD SHX Text
100 YEAR FLOOD ELEVATION
AutoCAD SHX Text
OF ALL WATERWAYS
AutoCAD SHX Text
LESS THAN 18" ABOVE 100
AutoCAD SHX Text
YEAR FLOOD ELEVATION
AutoCAD SHX Text
BY SEALING SYSTEMS, INC. NINE (9) INCH WIDTH
AutoCAD SHX Text
6" MINIMUM INDOT WASHED #8 STONE MAT FOR LEVELING AND SUPPORT
AutoCAD SHX Text
EAST JORDAN COMPOSITE
AutoCAD SHX Text
OF ALL WATERWAYS
AutoCAD SHX Text
EAST JORDAN COMPOSITE
AutoCAD SHX Text
LID
AutoCAD SHX Text
ALL CASTINGS TO BE SUPPLIED WITH FOUR (4) ANCHOR BOLT HOLES
AutoCAD SHX Text
COVER
AutoCAD SHX Text
55"
AutoCAD SHX Text
"CLEAN" SAND BACKFILL TO INFLUENT AND
AutoCAD SHX Text
"SANITARY SEWER"
AutoCAD SHX Text
TO UNDISTURBED EARTH (12" MINIMUM)
AutoCAD SHX Text
3" MIN
AutoCAD SHX Text
LID AND CASTING
AutoCAD SHX Text
LID AND CASTING
AutoCAD SHX Text
JOINTS BETWEEN ALL RISER AND ALL SECTIONS SHALL BE SEALED BY AN O-RING
AutoCAD SHX Text
8" MIN
AutoCAD SHX Text
INTERNAL MANHOLE JOINTS WITH NON-SHRINK GROUT.
AutoCAD SHX Text
EFFLUENT PIPES.
AutoCAD SHX Text
36"
AutoCAD SHX Text
36"
AutoCAD SHX Text
4"
AutoCAD SHX Text
4"
AutoCAD SHX Text
OPENING REQUIRED TO HAVE
AutoCAD SHX Text
A RESILIENT CONNECTOR
AutoCAD SHX Text
OR CAST IN PLACE A-LOC OR
AutoCAD SHX Text
HSE APPROVED EQUAL.
AutoCAD SHX Text
(TYPICAL ALL PIPE PENETRATIONS)
AutoCAD SHX Text
6" MIN
AutoCAD SHX Text
4" MIN
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
CONCRETE FILL AND GROUT
AutoCAD SHX Text
TO MEET SLOPE REQUIREMENT
AutoCAD SHX Text
H
AutoCAD SHX Text
S
AutoCAD SHX Text
E
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
Y
AutoCAD SHX Text
R
AutoCAD SHX Text
T
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
R
AutoCAD SHX Text
W
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
ANCHORED INTO FLAT TOP
AutoCAD SHX Text
18"
AutoCAD SHX Text
54" MINIMUM
AutoCAD SHX Text
INFLUENT
AutoCAD SHX Text
EFFLUENT
AutoCAD SHX Text
HAMILTON SOUTHEASTERN UTILITIES, INC.
AutoCAD SHX Text
"SANITARY SEWER - HSE"
AutoCAD SHX Text
(4) 3/8" x 3" STAINLESS STEEL
AutoCAD SHX Text
HEAVY DUTY SOLID
AutoCAD SHX Text
(SLOPE AWAY FROM CASTING)
AutoCAD SHX Text
HEAVY DUTY SOLID
AutoCAD SHX Text
MANHOLE CASTING TABLE
AutoCAD SHX Text
100 YEAR FLOOD ELEVATION
AutoCAD SHX Text
18" INCHES OR MORE ABOVE
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
LESS THAN 18" ABOVE 100
AutoCAD SHX Text
YEAR FLOOD ELEVATION
AutoCAD SHX Text
OF ALL WATERWAYS
AutoCAD SHX Text
OWNERSHIP
AutoCAD SHX Text
OF ALL WATERWAYS
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
EAST JORDAN 1050-Z1
AutoCAD SHX Text
EAST JORDAN 1050-Z1WT
AutoCAD SHX Text
LID
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
LETTERING
AutoCAD SHX Text
COVER
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
(SEE MANHOLE CASTING
AutoCAD SHX Text
FRAME AND COVER
AutoCAD SHX Text
TABLE FOR DETAILS) (TYPICAL)
AutoCAD SHX Text
CORE DRILLED OPENING
AutoCAD SHX Text
WITH RESILIENT CONNECTOR
AutoCAD SHX Text
OR CAST IN PLACE A-LOC OR
AutoCAD SHX Text
HSE APPROVED EQUAL.
AutoCAD SHX Text
(TYPICAL ALL PIPE PENETRATIONS)
AutoCAD SHX Text
ANCHOR BOLTS (TYPICAL)
AutoCAD SHX Text
LIQUID DEPTH
AutoCAD SHX Text
30" MINIMUM TO
AutoCAD SHX Text
78" MAXIMUM
AutoCAD SHX Text
**
AutoCAD SHX Text
1) INTERCEPTOR/SEPARATOR SHALL CONFORM
AutoCAD SHX Text
TO ASTM C 478 UTILIZING 4,000 PSI
AutoCAD SHX Text
CONCRETE. CONTRACTOR MAY SUPPLY
AutoCAD SHX Text
INTERCEPTOR/SEPARATORS AS
AutoCAD SHX Text
MANUFACTURED BY SCHIER PRODUCTS (www.schierproducts.com)
AutoCAD SHX Text
MODEL NUMBER GB-250 GREAT BASIN GREASE INTERCEPTOR.
AutoCAD SHX Text
2) EXTERIOR INSTALLATION MUST BE CONCRETE OR CAST IRON.
AutoCAD SHX Text
STEEL INTERCEPTORS/SEPARATORS SHALL ONLY BE INSTALLED INSIDE
AutoCAD SHX Text
A BUILDING.
AutoCAD SHX Text
DISTANCE MAY BE INCREASED
AutoCAD SHX Text
BASED ON THE CONSTITUENTS
AutoCAD SHX Text
OF THE WASTE WATER FLOWS.
AutoCAD SHX Text
CONSULT HSE PRIOR TO SHOP
AutoCAD SHX Text
DRAWING SUBMITTAL.
AutoCAD SHX Text
MINIMUM LIQUID DEPTH MAY BE
AutoCAD SHX Text
REDUCED ON A CASE-BY-CASE
AutoCAD SHX Text
BASIS AS APPROVED BY HSE.
AutoCAD SHX Text
*
AutoCAD SHX Text
**
AutoCAD SHX Text
JOINT DETAIL
AutoCAD SHX Text
STAINLESS STEEL SUPPORT PROVIDED
AutoCAD SHX Text
24" RCP RISER
AutoCAD SHX Text
*
AutoCAD SHX Text
#2 STONE AS REQUIRED BY HSE FOR
AutoCAD SHX Text
TO UNDISTURBED EARTH (12" MINIMUM)
AutoCAD SHX Text
OF INTERNAL OR EXTERNAL JOINTS.
AutoCAD SHX Text
OUTSIDE DIAMETER + 1' FOR PRE-CAST
AutoCAD SHX Text
STABLE GROUND PER HSE.
AutoCAD SHX Text
UNSTABLE SOIL CONDITIONS - DEPTH TO
AutoCAD SHX Text
EFFLUENT PIPES.
AutoCAD SHX Text
"CLEAN" SAND BACKFILL TO INFLUENT AND
AutoCAD SHX Text
(TYPICAL)
AutoCAD SHX Text
2'-0"%%C
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
1) SIZE AS PER CODE OR LOCAL REQUIREMENTS. THE SIZING
AutoCAD SHX Text
METHOD FOR ALL STRUCTURES MUST BE APPROVED BY HSE.
AutoCAD SHX Text
2) THE BAFFLE ORIENTATION WILL BE DEPENDENT UPON THE
AutoCAD SHX Text
APPLICATION.
AutoCAD SHX Text
3) SHOP DRAWINGS MUST BE SUBMITTED TO HSE FOR REVIEW
AutoCAD SHX Text
AND APPROVAL.
AutoCAD SHX Text
NO CORE WILL BE PERMITTED WITHIN 6"
AutoCAD SHX Text
KENT SEAL No2 PREMIUM
AutoCAD SHX Text
M
AutoCAD SHX Text
GRADE BUTYL RUBBER SEALANT
AutoCAD SHX Text
T
AutoCAD SHX Text
or FLEXIBLE BUTYL RESIN CONCRETE
AutoCAD SHX Text
SEALANT (ROPE) CONFORMING TO
AutoCAD SHX Text
ASTM C990
AutoCAD SHX Text
SEE JOINT DETAIL
AutoCAD SHX Text
OR FLANGE OF
AutoCAD SHX Text
ADJUSTING RING
AutoCAD SHX Text
CASTING
AutoCAD SHX Text
PRECAST CONCRETE
AutoCAD SHX Text
JOINTS BETWEEN ALL RISER AND ALL SECTIONS SHALL BE SEALED BY A
AutoCAD SHX Text
FLEXIBLE BUTYL RESIN CONCRETE SEALANT (ROPE) CONFORMING TO ASTM C 990.
AutoCAD SHX Text
COMPOSITION AND THICKNESS OF MATERIAL SHALL BE DEPENDENT ON SEASON OF
AutoCAD SHX Text
INSTALLATION AND AS DIRECTED BY ENGINEER. CONTRACTOR SHALL GROUT ALL
AutoCAD SHX Text
INTERNAL MANHOLE JOINTS WITH NON-SHRINK GROUT.
AutoCAD SHX Text
EACH MANHOLE SECTION SHALL BE SEALED WITH AN EXTERNAL
AutoCAD SHX Text
RUBBER SLEEVE OF INFI-SHEILD GATOR WRAP AS MANUFACTURED
AutoCAD SHX Text
BY SEALING SYSTEMS, INC. NINE (9) INCH WIDTH
AutoCAD SHX Text
36"
AutoCAD SHX Text
6"
AutoCAD SHX Text
72"
AutoCAD SHX Text
12" MINIMUM INDOT WASHED #8 STONE MAT FOR LEVELING AND SUPPORT
AutoCAD SHX Text
COMPARTMENT
AutoCAD SHX Text
SEDIMENT HOLDING
AutoCAD SHX Text
ALL CASTINGS TO BE SUPPLIED WITH FOUR (4) ANCHOR BOLT HOLES
AutoCAD SHX Text
PRIVATE
AutoCAD SHX Text
"SANITARY SEWER"
AutoCAD SHX Text
FROST LINE
AutoCAD SHX Text
MODEL NUMBER SV24-06 BELOW GRADE SAMPLING PORT.
AutoCAD SHX Text
53"
AutoCAD SHX Text
55"
AutoCAD SHX Text
20"
AutoCAD SHX Text
TEE
AutoCAD SHX Text
1'-5" MIN.
AutoCAD SHX Text
24" RCP RISER
AutoCAD SHX Text
12"
AutoCAD SHX Text
12"
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
TEE
AutoCAD SHX Text
SEE DETAIL
AutoCAD SHX Text
WYE
AutoCAD SHX Text
8"
AutoCAD SHX Text
6"
AutoCAD SHX Text
LIQUID LEVEL
AutoCAD SHX Text
EXTERIOR INTERCEPTOR/SEPARATOR DETAIL
AutoCAD SHX Text
30"
AutoCAD SHX Text
74"
AutoCAD SHX Text
36"
AutoCAD SHX Text
FIELD INSTALLED BY OTHERS (TYP)
AutoCAD SHX Text
FOR 6" PVC PIPE
AutoCAD SHX Text
16"
AutoCAD SHX Text
10"
AutoCAD SHX Text
CONTAINMENT
AutoCAD SHX Text
MONOLITHIC
AutoCAD SHX Text
BAFFLE
AutoCAD SHX Text
34"
AutoCAD SHX Text
(TYPICAL)
AutoCAD SHX Text
2'-0" %%C
AutoCAD SHX Text
19"
AutoCAD SHX Text
19"
AutoCAD SHX Text
72"
AutoCAD SHX Text
36"
AutoCAD SHX Text
SINGLE ROW OF CENTERED KENT SEAL No2 PREMIUM
AutoCAD SHX Text
TOP SLAB 5700 lbs
AutoCAD SHX Text
STRUCTURE TO BE SEALED IN THE FIELD WITH A
AutoCAD SHX Text
APPROXIMATE WEIGHTS:
AutoCAD SHX Text
CONFORMING TO ASTM 990
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
M
AutoCAD SHX Text
T
AutoCAD SHX Text
114"
AutoCAD SHX Text
McCREARY CONCRETE PRODUCTS, INC
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
or FLEXIBLE BUTYL RESIN CONCRETE SEALANT (ROPE)
AutoCAD SHX Text
BASE SECTION 9375 lbs
AutoCAD SHX Text
OF ANY PAVED OR CONCRETE SURFACES.
AutoCAD SHX Text
STRUCTURE WEIGHT TOTAL 22725 lbs
AutoCAD SHX Text
3'-0" MAXIMUM
AutoCAD SHX Text
RISER SECTION 7650 lbs
AutoCAD SHX Text
2'-0" %%C
AutoCAD SHX Text
UNLESS APPROVED BY HSE, CASTINGS MUST NOT
AutoCAD SHX Text
(FOR CONCRETE STRUCTURES)
AutoCAD SHX Text
2'-0" MINIMUM
AutoCAD SHX Text
TOP OF CASTING SHALL EXTEND
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
0.20 FEET MINIMUM ABOVE FINISHED GRADE.
AutoCAD SHX Text
BE WITHIN ONE (1) FOOT HORIZONTAL DISTANCE
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
MINIMUM (1) (TYPICAL)
AutoCAD SHX Text
CRE-TEX ADJUSTING RING
AutoCAD SHX Text
STAINLESS STEEL SUPPORT PROVIDED
AutoCAD SHX Text
FIELD INSTALLED BY OTHERS (TYP)
AutoCAD SHX Text
FOR 6" PVC PIPE