Page 1: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

INSULATED METAL PANELSISOLEREN

Page 2: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

• Exterior Profi le: Isoleren RL

• Interior Profi le: Isoleren ML

• Rib Type: 2.375” tall, tee-shaped rib with separate batten

• Attachment: Mechanically seamed rib with clip

• Exterior Gauge: 26, 24, 22

• Interior Gauge: 26, 24, 22

• Substrate: Galvalume®, G90 Galvanized and Stainless Steel

• Exterior Finish: Kynar 500® PVDF or Hylar 5000® PVDF, standard gloss

• Interior Finish: Polyester, standard gloss (USDA White)

• Coverage Width (B): 42-inch

• Thickness (A): 2.5, 3, 4 and 5-inch

• Exterior Texture: Smooth

• Interior Texture: Embossed and Smooth

• Core: Continuously poured-in-place, polyisocyanurate, insulating foam

• K-factor: 0.138 Btu-in/hr-ft2-F° @ 75° F mean temperature (R-7.25)

0.129 Btu-in/hr-ft2-F° @ 35° F mean temperature (R-7.75)

• Weight, Insulation: 2.50 pounds per cubic foot (nominal)

• Weight, Steel: 2.00 pounds per square foot (nominal)

• Standard Lengths: 12’-0” to 53’-0”

• Minimum Slope: 1/2:12

• Note: All information subject to change without notice. Please reference website for

most current data.

Isoleren RLIN

SU

LA

TE

D M

ETA

L R

OO

F P

AN

ELS

TEC

HN

ICA

L D

ATA

SH

EE

T

TESTING

• Exterior Profi le: Isoleren RL

PANEL CROSS-SECTION

PANEL SIDELAP

6612 Snowdrift Rd.

Allentown, PA 18106

www.atas.com

800.468.1441

TYPE TEST PROTOCOL DESCRIPTION

ENVIRONMENTAL PERFORMANCE

ASTM C518 Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

ASTM E1680 Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specifi ed Pressure Difference Across the Specimen

ASTM E1646 Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure

FOAM CORECHARACTERISTICS

ASTM C273 Shear Properties of Sandwich Core Metals

ASTM D1621 Compressive Properties of Rigid Cellular Plastics

ASTM D1622 Apparent Density of Rigid Cellular Plastics

ASTM D1623 Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

ASTM D6226 Open Cell Content of Rigid Cellular Plastics

FIRE RESISTANCE ASTM E84 Surface Burning Characteristics of Building Materials

ENGINEERNGPROPERTIES

ASTM E1592 Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

ASTM E72 Strength Tests of Panels for Building Construction

Page 3: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

TESTING

Isoleren IN

• Exterior Profi le: Isoleren IN

• Interior Profi le: Isoleren ML

• Available Reveal: 1.25-inch

• Exterior Gauge: 22

• Interior Gauge: 26, 24, 22

• Substrate: Galvalume®, G90 Galvanized and Stainless Steel

• Exterior Finish: Kynar 500® PVDF or Hylar 5000® PVDF, low gloss

• Interior Finish: Polyester, standard gloss (USDA white)

• Coverage Width (B): 36 and 30-inch

• Thickness (A): 2, 2.5, 3 and 4-inch

• Exterior Texture: Smooth

• Interior Texture: Embossed and Smooth

• Core: Continuously poured-in-place, polyisocyanurate, insulating foam

• K-factor: 0.138 Btu-in/hr-ft2-F° @ 75° F mean temperature (R-7.25)

0.129 Btu-in/hr-ft2-F° @ 35° F mean temperature (R-7.75)

• Weight, Insulation: 2.50 pounds per cubic foot (nominal)

• Weight, Steel: 2.00 pounds per square foot (nominal)

• Standard Lengths: 8’-0” to 32’-0”

• Note: All information subject to change without notice. Please reference website for

most current data.

PANEL CROSS-SECTION

PANEL SIDELAP

INS

ULA

TE

D M

ETA

L W

ALL P

AN

ELS

TEC

HN

ICA

L D

ATA

SH

EE

T

6612 Snowdrift Rd.

Allentown, PA 18106

www.atas.com

800.468.1441

TYPE TEST PROTOCOL DESCRIPTION

ENVIRONMENTAL PERFORMANCE

ASTM C518 Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

ASTM E283 Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specifi ed Pressure Difference Across the Specimen

ASTM E331 Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

FOAM CORECHARACTERISTICS

ASTM C273 Shear Properties of Sandwich Core Metals

ASTM D1621 Compressive Properties of Rigid Cellular Plastics

ASTM D1622 Apparent Density of Rigid Cellular Plastics

ASTM D1623 Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

ASTM D6226 Open Cell Content of Rigid Cellular Plastics

FIRE RESISTANCE

ASTM E84 Surface Burning Characteristics of Building Materials

FM 4880Factory Mutual Approval Standard for Class 1 Fire Rating of Insu-lated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings and Exterior Wall Systems

ENGINEERNGPROPERTIES

ASTM E1592 Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

ASTM E72 Strength Tests of Panels for Building Construction

Page 4: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

Isoleren ST

TESTING

• Exterior Profi le: Isoleren ST

• Interior Profi le: Isoleren ML

• Available Reveal: 1.25-inch

• Exterior Gauge: 22

• Interior Gauge: 26, 24 or 22

• Substrate: Galvalume®, G90 Galvanized and Stainless Steel

• Exterior Finish: Kynar 500® PVDF or Hylar 5000® PVDF, low gloss

• Interior Finish: Polyester, standard gloss (USDA white)

• Coverage Width (B): 36 and 30-inch

• Thickness (A): 2, 2.5, 3 and 4-inch

• Exterior Texture: Embossed

• Interior Texture: Embossed and Smooth

• Core: Continuously poured-in-place, polyisocyanurate, insulating foam

• K-factor: 0.138 Btu-in/hr-ft2-F° @ 75° F mean temperature (R-7.25)

0.129 Btu-in/hr-ft2-F° @ 35° F mean temperature (R-7.75)

• Weight, Insulation: 2.50 pounds per cubic foot (nominal)

• Weight, Steel: 2.00 pounds per square foot (nominal)

• Standard Lengths: 8’-0” to 32’-0”

• Note: All information subject to change without notice. Please reference website for most current data.

PANEL CROSS-SECTION

PANEL SIDELAP

INS

ULA

TE

D M

ETA

L W

ALL P

AN

ELS

TEC

HN

ICA

L D

ATA

SH

EE

T

6612 Snowdrift Rd.

Allentown, PA 18106

www.atas.com

800.468.1441

TYPE TEST PROTOCOL DESCRIPTION

ENVIRONMENTAL PERFORMANCE

ASTM C518 Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

ASTM E283 Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specifi ed Pressure Difference Across the Specimen

ASTM E331 Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

FOAM CORECHARACTERISTICS

ASTM C273 Shear Properties of Sandwich Core Metals

ASTM D1621 Compressive Properties of Rigid Cellular Plastics

ASTM D1622 Apparent Density of Rigid Cellular Plastics

ASTM D1623 Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

ASTM D6226 Open Cell Content of Rigid Cellular Plastics

FIRE RESISTANCE

ASTM E84 Surface Burning Characteristics of Building Materials

FM 4880Factory Mutual Approval Standard for Class 1 Fire Rating of Insu-lated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings and Exterior Wall Systems

ENGINEERNGPROPERTIES

ASTM E1592 Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

ASTM E72 Strength Tests of Panels for Building Construction

Page 5: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

Isoleren IM

TESTING

• Exterior Profi le: Isoleren IM

• Interior Profi le: Isoleren ML

• Exterior Gauge: 26, 24

• Interior Gauge: 26, 24, 22

• Substrate: Galvalume®, G90 Galvanized and Stainless Steel

• Exterior Finish: Kynar 500® PVDF or Hylar 5000® PVDF, low gloss

• Interior Finish: Polyester, standard gloss (USDA white)

• Coverage Width (B): 42, 36, and 30-inch

• Thickness (A): 2, 2.5, 3 or 4-inch

• Exterior Texture: Heavy Embossed

• Interior Texture: Embossed and Smooth

• Core: Continuously poured-in-place, polyisocyanurate, insulating foam

• K-factor: 0.138 Btu-in/hr-ft2-F° @ 75° F mean temperature (R-7.25)

0.129 Btu-in/hr-ft2-F° @ 35° F mean temperature (R-7.75)

• Weight, Insulation: 2.50 pounds per cubic foot (nominal)

• Weight, Steel: 2.00 pounds per square foot (nominal)

• Standard Lengths: 8’-0” to 40’-0”

• Note: All information subject to change without notice. Please reference website for most current data.

PANEL CROSS-SECTION

PANEL SIDELAP INS

ULA

TE

D M

ETA

L W

ALL P

AN

ELS

TEC

HN

ICA

L D

ATA

SH

EE

T

6612 Snowdrift Rd.

Allentown, PA 18106

www.atas.com

800.468.1441

TYPE TEST PROTOCOL DESCRIPTION

ENVIRONMENTAL PERFORMANCE

ASTM C518 Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

ASTM E283 Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specifi ed Pressure Difference Across the Specimen

ASTM E331 Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

FOAM CORECHARACTERISTICS

ASTM C273 Shear Properties of Sandwich Core Metals

ASTM D1621 Compressive Properties of Rigid Cellular Plastics

ASTM D1622 Apparent Density of Rigid Cellular Plastics

ASTM D1623 Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

ASTM D6226 Open Cell Content of Rigid Cellular Plastics

FIRE RESISTANCE

ASTM E84 Surface Burning Characteristics of Building Materials

FM 4880Factory Mutual Approval Standard for Class 1 Fire Rating of Insu-lated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings and Exterior Wall Systems

ENGINEERNGPROPERTIES

ASTM E1592 Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

ASTM E72 Strength Tests of Panels for Building Construction

Page 6: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

Isoleren ML

TESTING

• Exterior Profi le: Isoleren ML

• Interior Profi le: Isoleren ML

• Exterior Gauge: 26, 24, 22

• Interior Gauge: 26, 24, 22

• Substrate: Galvalume®, G90 Galvanized and Stainless Steel

• Exterior Finish: Kynar 500® PVDF or Hylar 5000® PVDF, low gloss

• Interior Finish: Polyester, standard gloss (USDA white)

• Coverage Width (B): 42 and 36-inch

• Thickness (A): 2, 2.5, 3, 4, 5 and 6-inch

• Exterior Texture: Embossed and Smooth

• Interior Texture: Embossed and Smooth

• Core: Continuously poured-in-place, polyisocyanurate, insulating foam

• K-factor: 0.138 Btu-in/hr-ft2-F° @ 75° F mean temperature (R-7.25)

0.129 Btu-in/hr-ft2-F° @ 35° F mean temperature (R-7.75)

• Weight, Insulation: 2.50 pounds per cubic foot (nominal)

• Weight, Steel: 2.00 pounds per square foot (nominal)

• Standard Lengths: 8’-0” to 53’-0”

• Note: All information subject to change without notice. Please reference website for most current data.

PANEL CROSS-SECTION

PANEL SIDELAP

INS

ULA

TE

D M

ETA

L W

ALL P

AN

ELS

TEC

HN

ICA

L D

ATA

SH

EE

T

6612 Snowdrift Rd.

Allentown, PA 18106

www.atas.com

800.468.1441

TYPE TEST PROTOCOL DESCRIPTION

ENVIRONMENTAL PERFORMANCE

ASTM C518 Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

ASTM E283 Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specifi ed Pressure Difference Across the Specimen

ASTM E331 Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

FOAM CORECHARACTERISTICS

ASTM C273 Shear Properties of Sandwich Core Metals

ASTM D1621 Compressive Properties of Rigid Cellular Plastics

ASTM D1622 Apparent Density of Rigid Cellular Plastics

ASTM D1623 Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

ASTM D6226 Open Cell Content of Rigid Cellular Plastics

FIRE RESISTANCE

ASTM E84 Surface Burning Characteristics of Building Materials

FM 4880Factory Mutual Approval Standard for Class 1 Fire Rating of Insu-lated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings and Exterior Wall Systems

ENGINEERNGPROPERTIES

ASTM E1592 Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

ASTM E72 Strength Tests of Panels for Building Construction

Page 7: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

Isoleren VL

TESTING

• Exterior Profi le: Isoleren VL

• Interior Profi le: Isoleren ML

• Exterior Gauge: 26, 24, 22

• Interior Gauge: 26, 24, 22

• Substrate: Galvalume®, G90 Galvanized and Stainless Steel

• Exterior Finish: Kynar 500® PVDF or Hylar 5000® PVDF, low gloss

• Interior Finish: Polyester, standard gloss (USDA white)

• Coverage Width (B): 42 and 36-inch

• Thickness (A): 2, 2.5, 3, 4, 5 and 6-inch

• Exterior Texture: Embossed and Smooth

• Interior Texture: Embossed and Smooth

• Core: Continuously poured-in-place, polyisocyanurate, insulating foam

• K-factor: 0.138 Btu-in/hr-ft2-F° @ 75° F mean temperature (R-7.25)

0.129 Btu-in/hr-ft2-F° @ 35° F mean temperature (R-7.75)

• Weight, Insulation: 2.50 pounds per cubic foot (nominal)

• Weight, Steel: 2.00 pounds per square foot (nominal)

• Standard Lengths: 8’-0” to 53’-0”

• Note: All information subject to change without notice. Please reference website for most current data.

PANEL CROSS-SECTION

PANEL SIDELAP INS

ULA

TE

D M

ETA

L W

ALL P

AN

ELS

TEC

HN

ICA

L D

ATA

SH

EE

T

6612 Snowdrift Rd.

Allentown, PA 18106

www.atas.com

800.468.1441

TYPE TEST PROTOCOL DESCRIPTION

ENVIRONMENTAL PERFORMANCE

ASTM C518 Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

ASTM E283 Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specifi ed Pressure Difference Across the Specimen

ASTM E331 Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

FOAM CORECHARACTERISTICS

ASTM C273 Shear Properties of Sandwich Core Metals

ASTM D1621 Compressive Properties of Rigid Cellular Plastics

ASTM D1622 Apparent Density of Rigid Cellular Plastics

ASTM D1623 Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

ASTM D6226 Open Cell Content of Rigid Cellular Plastics

FIRE RESISTANCE

ASTM E84 Surface Burning Characteristics of Building Materials

FM 4880Factory Mutual Approval Standard for Class 1 Fire Rating of Insu-lated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings and Exterior Wall Systems

ENGINEERNGPROPERTIES

ASTM E1592 Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

ASTM E72 Strength Tests of Panels for Building Construction

Page 8: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

Isoleren WL

TESTING

• Exterior Profi le: Isoleren WL

• Interior Profi le: Isoleren ML

• Exterior Gauge: 24, 22

• Interior Gauge: 26, 24, 22

• Substrate: Galvalume®, G90 Galvanized and Stainless Steel

• Exterior Finish: Kynar 500® PVDF or Hylar 5000® PVDF, low gloss

• Interior Finish: Polyester, standard gloss (USDA white)

• Coverage Width (B): 42, 36, and 30-inch

• Thickness (A): 2, 2.5, 3 and 4-inch

• Exterior Texture: Embossed and Smooth

• Interior Texture: Embossed and Smooth

• Core: Continuously poured-in-place, polyisocyanurate, insulating foam

• K-factor: 0.138 Btu-in/hr-ft2-F° @ 75° F mean temperature (R-7.25)

0.129 Btu-in/hr-ft2-F° @ 35° F mean temperature (R-7.75)

• Weight, Insulation: 2.50 pounds per cubic foot (nominal)

• Weight, Steel: 2.00 pounds per square foot (nominal)

• Standard Lengths: 8’-0” to 40’-0”

• Note: All information subject to change without notice. Please reference website for most current data.

PANEL CROSS-SECTION

PANEL SIDELAP INS

ULA

TE

D M

ETA

L W

ALL P

AN

ELS

TEC

HN

ICA

L D

ATA

SH

EE

T

6612 Snowdrift Rd.

Allentown, PA 18106

www.atas.com

800.468.1441

TYPE TEST PROTOCOL DESCRIPTION

ENVIRONMENTAL PERFORMANCE

ASTM C518 Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

ASTM E283 Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specifi ed Pressure Difference Across the Specimen

ASTM E331 Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

FOAM CORECHARACTERISTICS

ASTM C273 Shear Properties of Sandwich Core Metals

ASTM D1621 Compressive Properties of Rigid Cellular Plastics

ASTM D1622 Apparent Density of Rigid Cellular Plastics

ASTM D1623 Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

ASTM D6226 Open Cell Content of Rigid Cellular Plastics

FIRE RESISTANCE

ASTM E84 Surface Burning Characteristics of Building Materials

FM 4880Factory Mutual Approval Standard for Class 1 Fire Rating of Insu-lated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings and Exterior Wall Systems

ENGINEERNGPROPERTIES

ASTM E1592 Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

ASTM E72 Strength Tests of Panels for Building Construction

Page 9: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

Isoleren SL

TESTING

• Exterior Profi le: Isoleren SL

• Interior Profi le: Isoleren ML

• Exterior Gauge: 26, 24, 22

• Interior Gauge: 26, 24, 22

• Substrate: Galvalume®, G90 Galvanized and Stainless Steel

• Exterior Finish: Kynar 500® PVDF or Hylar 5000® PVDF, low gloss

• Interior Finish: Polyester, standard gloss (USDA white)

• Coverage Width (B): 42-inch

• Thickness (A): 2, 2.5, 3, 4, 5 and 6-inch

• Exterior Texture: Embossed and Smooth

• Interior Texture: Embossed and Smooth

• Core: Continuously poured-in-place, polyisocyanurate, insulating foam

• K-factor: 0.138 Btu-in/hr-ft2-F° @ 75° F mean temperature (R-7.25)

0.129 Btu-in/hr-ft2-F° @ 35° F mean temperature (R-7.75)

• Weight, Insulation: 2.50 pounds per cubic foot (nominal)

• Weight, Steel: 2.00 pounds per square foot (nominal)

• Standard Lengths: 8’-0” to 53’-0”

• Note: All information subject to change without notice. Please reference website for most current data.

PANEL CROSS-SECTION

PANEL SIDELAP INS

ULA

TE

D M

ETA

L W

ALL P

AN

ELS

TEC

HN

ICA

L D

ATA

SH

EE

T

6612 Snowdrift Rd.

Allentown, PA 18106

www.atas.com

800.468.1441

TYPE TEST PROTOCOL DESCRIPTION

ENVIRONMENTAL PERFORMANCE

ASTM C518 Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

ASTM E283 Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specifi ed Pressure Difference Across the Specimen

ASTM E331 Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

FOAM CORECHARACTERISTICS

ASTM C273 Shear Properties of Sandwich Core Metals

ASTM D1621 Compressive Properties of Rigid Cellular Plastics

ASTM D1622 Apparent Density of Rigid Cellular Plastics

ASTM D1623 Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

ASTM D6226 Open Cell Content of Rigid Cellular Plastics

FIRE RESISTANCE

ASTM E84 Surface Burning Characteristics of Building Materials

FM 4880Factory Mutual Approval Standard for Class 1 Fire Rating of Insu-lated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings and Exterior Wall Systems

ENGINEERNGPROPERTIES

ASTM E1592 Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

ASTM E72 Strength Tests of Panels for Building Construction

Page 10: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

IsolerenFIRE RATED PANEL

0315

PERFORMANCE

• Exterior Profi le: Isoleren MF, VF, SF

• Interior Profi le: Isoleren ML

• Exterior Gauge: 26 (0.020”), 24 (0.023”)

• Interior Gauge: 26 (0.020”)

• Substrate: Galvalume®, G90 Galvanized (Grade 33) and Stainless Steel (Type 304)

• Exterior Finish: 1.0 mil thick Kynar 500®

• Interior Finish: Siliconized Polyester (USDA white), Plastisol available

• Coverage Width (B): 47.375-inch

• Thickness (A): 4, 5, 6, 8, 10 and 12-inch

• Exterior Texture: Embossed

• Interior Texture: Embossed

• Core: ROXUL® ConRock L structural mineral wool

• K-factor: 0.277 Btu-in/hr-ft2-F° @ 40° F mean temperature (R-3.61)

• Splines: Fiber-reinforced cement board (½” x 2-¾” x 8’ long)

• Available Lengths: Minimum 8’-0” to maximum 30’-0”; over 30’-0”, please inquire

• Note: All information subject to change without notice. Please reference website for most current data.

Panel Thickness Fire Rating Weight Thermal U-factor R-factor

(in.) (hr.) (psf) (BTU / hr • ft2 • F°) (hr • ft2 • F° / BTU)

4 1 4.6 0.069 14.49

5 2 5.3 0.055 18.18

6 3 6.0 0.046 21.74

8 3 7.5 0.035 28.57

10 3 8.9 0.028 35.71

12 3 10.3 0.023 43.48

Panel Thickness Uniform Load (psf)

(in.) 5 10 15 20 25 30 40

4 22.2 15.7 12.8 11.1 9.9 8.2 6.2

5 24.8 17.5 14.2 12.4 10.6 9.1 6.8

6 27.3 19.3 15.7 13.6 12.1 10.1 7.6

8 31.5 22.3 18.2 15.8 14.0 11.6 8.7

10 35.2 24.9 20.3 17.6 15.6 13.0 9.8

12 38.6 27.3 22.3 19.3 17.1 14.2 10.7

PANEL CROSS-SECTION

PANEL SIDELAP

INS

ULA

TE

D M

ETA

L W

ALL P

AN

ELS

TEC

HN

ICA

L D

ATA

SH

EE

T

6612 Snowdrift Rd.

Allentown, PA 18106

www.atas.com

800.468.1441

Page 11: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

Standard Siliconized Polyester Roof and Wall Colors In-stock, Standard Gloss Standard Polyester Interior Only

REGAL WHITE IISR:0.61 E:0.88 SRI: 73

LIGHT STONESR:0.50 E:0.86 SRI: 57

GRAY STONESR:0.41 E:0.86 SRI: 45

REGAL WHITE I

SURREY BEIGELow gloss: SR:0.48 E:0.87 SRI: 55

ROMAN BLUELow gloss: SR:0.26 E:0.87 SRI: 25

Notes:Kynar 500® is a registered trademark of Arkema, Inc.Hylar 5000® is a registered trademark of Solvay Solexis.All coatings have a min/max thickness, average thickness is shown.

Flurothane® IV

0.75 mil color coat1 mil primer1 mil primer1 mil primer

substrate

Fluropon Classic® IIMica Sparkle

1.15 mil color coat0.25 mil primer

substrate

Fluropon Premiere

0.45 mil clear coat0.75 mil color coat

0.25 mil primersubstrate

Valshield®Thick Film Plastisol

2.0-10.0 mil color coat0.10 mil primer

substrate

Flurothane® II

0.75 mil color coat1 mil primer

substrate

Fluropon Classic®Metallic Sparkle

0.45 mil clear coat0.90 mil color coat

0.25 mil primersubstrate

Fluropon®, WeatherX® & Dynapon®

0.75 mil color coat0.25 mil primer

substrate

Standard Fluropon PVDF Wall and Roof Colors In-stock, Low Gloss (wall applications), In-stock, Standard Gloss (roof applications)

PATINA GREENLow gloss: SR:0.38 E:0.87 SRI: 41Std gloss: SR:0.46 E:0.85 SRI: 51

SANDSTONELow gloss: SR:0.59 E:0.87 SRI: 70Std gloss: SR:0.54 E:0.86 SRI: 63

REGAL WHITE IIILow gloss: SR:0.66 E:0.87 SRI: 80Std gloss: SR:0.68 E:0.86 SRI: 82

ALMONDLow gloss: SR:0.62 E:0.87 SRI: 74Std gloss: SR:0.60 E:0.84 SRI: 70

ASH GRAYLow gloss: SR:0.48 E:0.87 SRI: 55Std gloss: SR:0.39 E:0.84 SRI: 41

Premium Metallics Special Colors, Not in-stock, Additional Costs Will Apply

TEXAS SILVERSR:0.58 E:0.78 SRI: 66

LEADCOATSR:0.37 E:0.82 SRI: 38

WEATHERED GALVALUMESR:0.30 E:0.79 SRI: 27

CHAMPAGNESR:0.38 E:0.80 SRI: 38

COPPER PENNYSR:0.49 E:0.85 SRI: 55

Notes:The colors above are representative and may vary slightly from actual colors. Prior to making fi nal selections, please request actual color chip samples. All information is subject to change without notice.

Available Coating Products

Page 12: ISOLEREN INSULATED METAL PANELS - atas. · PDF fileIsoleren ML TESTING • Exterior Profi le: Isoleren ML • Interior Profi le: Isoleren ML • Exterior Gauge: 26, 24, 22 • Interior

ATAS International, Inc.ATAS International, Inc.Allentown, PA Mesa, AZ Maryville, TN

800.468.1441 | www.atas.com | [email protected]

Contact ATAS for more information. ATAS reserves the right to modify, eliminate and/or change its products without prior notification.

© 2015 ATAS International, Inc. LRD1115 LAT118

ATAS’ s professional sta� is able to assist in the design or provide shop drawings for your project. Final choice of materials and installation is the responsibility of the owner, architect and/or the owner’s agent. ATAS International, Inc. cannot be held responsible for the ultimate selection or the installation of those materials. Due to slight stress in metal materials and substrates to which metal panels are applied, installed panels may exhibit a perceived waviness in the � at areas of the panel. Commonly the period and amplitude of the waviness is dependent upon the continuous � at width of the panel. This condition is beyond the control of ATAS and consequently this perceived waviness or “oil canning” of the product is not a valid reason for rejection of materials. (Refer to ASTM E 1514, ASTM E 1637 and Metal Construction Association Technical Bulletin 1060 for further clari� cation). ATAS reserves the right to modify, eliminate and/or change its products without prior noti� cation. ATAS cannot be held responsible for errors in line drawings and typesetting. Inquire for availability.

Visit us online

Get product info

Browse photos

View tech data

Download CAD Details

Try our product visualizer

Advanta® Shingle

Dutch Seam®

Eco-Seam™ Field-Lok™

Granutile™

Grand C

Grand V

Monarch™ Batten Seam PC™ System

Rumba Shake™ ScanRoof™ Standing Seam Shingle™

Techo Tile®

Permashake™ Permashake™ II

Arc Panels Belvedere™ CastleTop®

Corra-Lok™ Corrugated Design Wall™

Gaten Series™

InSpire® Metafor™

Multi-Purpose™ Opaline™

Rigid Wall™ Rigid Wall II™

Span Wall™

SterraCore Versa-Lok™ Versa-Seam™

YOUR SINGLE SOURCE FOR METAL WALLS, ROOFS, CEILINGS, ACCESSORIES & MORE.