Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. इंटरनेट मानक !ान $ एक न’ भारत का +नम-णSatyanarayan Gangaram Pitroda “Invent a New India Using Knowledge” प0रा1 को छोड न’ 5 तरफJawaharlal Nehru “Step Out From the Old to the New” जान1 का अ+धकार, जी1 का अ+धकारMazdoor Kisan Shakti Sangathan “The Right to Information, The Right to Live” !ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता ह Bharthari—Nītiśatakam “Knowledge is such a treasure which cannot be stolen” IS 8897 (1978): Tables for Calibration and Method of Verification of Volumetric Glassware [CHD 10: Glassware]

Upload: others

Post on 18-Mar-2020

190 views

Category:

Documents


14 download

TRANSCRIPT

Page 1: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

Disclosure to Promote the Right To Information

Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public.

इंटरनेट मानक

“!ान $ एक न' भारत का +नम-ण”Satyanarayan Gangaram Pitroda

“Invent a New India Using Knowledge”

“प0रा1 को छोड न' 5 तरफ”Jawaharlal Nehru

“Step Out From the Old to the New”

“जान1 का अ+धकार, जी1 का अ+धकार”Mazdoor Kisan Shakti Sangathan

“The Right to Information, The Right to Live”

“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता है”Bhartṛhari—Nītiśatakam

“Knowledge is such a treasure which cannot be stolen”

“Invent a New India Using Knowledge”

है”ह”ह

IS 8897 (1978): Tables for Calibration and Method ofVerification of Volumetric Glassware [CHD 10: Glassware]

Page 2: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical
Page 3: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical
Page 4: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical
Page 5: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

Indian Standard TABLES FOR CALIBRATION AND METHOD OF VERIFICATION OF

VOLUMETRIC GLASSWARE

Laboratory Glassware and Related Apparatus Sectional Committee, CDC 33

Chairman

KUMARI A. M. MANI

Members

DR S. C. AGARWALA ASSISTANT DIRECTOR (MET INSPN-I),

Representing

India Meteorological Department, New Delhi

Central Drug Research Institute (CSIR), Lucknow Ministry of Railways

RDSO, CHI~ARANJAN ASSISTANT RESEARCH OPFICER-

(CM) I, RDSO, LUCKNOW (Alternate) DR G. S. BAJWA

DR BACHCHAN SINGH (Alternate) Ministry of Defence (R & D)

SHKI B. M. BANERJEE SHRI K. M. MONDAL (Alternate)

Ministry of Defence (DGI)

SHRI A. K. BHATTACHARYYA National Test House, Calcutta SHRI N. R. CHAKRAVERTY National Instruments Ltd, Calcutta

SHRI P. K. GHOSH (Alternate) SHRI M. K. CHITRE Development Commissioner (Small Scale

Industries), New Delhi GP CAPT H. N. DUTTA Ministry of Defence (DGAFMS) SHRI S. V. GULAVANE Bhabha Atomic Research Centre, Trombay SHRI S. R. KHANNA Directorate General of Technical Development,

New Delhi DR S. KUMAR Central Glass and Ceramic Research Institute

(CSIR), Calcutta SHRI MOHINDER NATH National Physical Laboratory (CSIR), New Delhi

SHRI B. G. MATHUR (Alternate) SHRI Y. S. NIMBKAR Haffkine Institute, Bombay SHRI H. K. PANDA The Utkal Equipment and Chemicals Ltd, Cuttack

SHRI S. K. BRAHMA (Alternate) DR V. RAMAKRISHNA Indian Institute of Technology, New Delhi SHRI SANTOKH SINGH National Chemical Industries, New Delhi

SHRI PRITHIPAL SINGH (Alternate)

(Continued on page 2)

Q Copyright 1980

INDIAN STANDARDS INSTITUTION

This publication is protected under the Indian Copyright Act (XIV of 1957) and reproduction in whole or in part by any means except with written permission of the publisher shall be deemed to be an infringement of copyright under the said Act.

Page 6: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

(Continued +om page 1)

Members Representing

SHRI SARUP SIRCAR SHRI N. G. SIRCAR (Alternate)

DR P. G. TULPULE SHRI S. C. VARSHNEI

SHRI P. P. CHANDRA (Alternate) SHRI J. K. WAD

SHRI P. R. RAO (Alternate) DR G. M. SAXENA,

Director (Chem)

The Scientific Indian Glass Co Ltd, Calcutta

Indian Council of Medical Research, New Delhi Seraikella Glass Works Private Ltd, Kandra

Borosil Glass Works Ltd, Bombay

Director General, IS1 (Ex-o#cio Member)

Secretary

SHRI G. P. SARASWAT Deputy Director (Chem), ISI

Volumetric Glassware Subcommittee, CDC 33 : 1

SHRI J. K. WAD

Members

Borosil Glass Works Ltd, Bombay

SHRI P. R. RAO (Alternate to Shri J. K. Wad)

SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate)

SHRI MOHINDER NATH National Physical Laboratory (CSIR), New Delhi SHRI RAMA KANT Hi-Tech Precision Glass Ltd, Dholpur DR B. C. SINHA Central Glass and Ceramic Research Institute

(CSIR), Calcutta SHRI A. SIRCAR The Scientific Indian Glass Co Ltd. Calcutta

Panel for Preparing Tables for Calibration of Volumetric Glassware, CDC 33:l:l

Member-Convener

SHRI MOHINDER NATH National Physical Laboratory (CSIR), New Delhi

2

Page 7: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

Indian Standard TABLES FOR CALIBRATION AND METHOD OF VERIFICATION OF

VOLUMETRIC GLASSWARE

0. FOREWORD

0.1 This Indian Standard was adopted by the Indian Standards Institution on 20 January 1978, after the draft finalized by the Laboratory Glassware and Related Apparatus Sectional Committee had been approved by the Chemical Division Council,

0.2 This standard has been prepared with a view to providing necessary guidance in the calibration and verification of volumetric glassware using 27°C as the Indian Standard reference temperature. In this standard tables have been compiled to express capacities in terms of cubic centimetres (ems) in keeping with the decisions taken at the Twelfth Conf&ence GCnCrale des Poids et Mesures held in October 1964. According to this decision the term ‘millilitre’ should not be used for expressing volumes to high preci- sion, and if at all this term is used, it should be treated only as a special name for cubic centimetre, that is, one millilitre is equal to one cubic centimetre exactly.

0.3 This standard contains information regarding factors affecting accuracy of volumetric glassware and the basis and data used in the compilation of tables. Procedures based on the use of both water and mercury have been given along with snitable examples showing use of tables and application of corrections for computing capacities at 27°C as reference temperature.

0.4 Separate tables have been provided for vessels made of glass having co- efficients of cubical thermal expansion 10 x 1 O-e/oC, 15 x 10-6/oC, 25 x IO-S/ “C and 30 x 10-6/“C respectively. Tables based on the use of water have been provided for capacities most commonly in use in respect ofwares made of glass having coefficients of cubical thermal expansion 10 x 10-s/oC and 30 x 10-6/oC. In respect of the remaining two, tables have been provided for capacity of 1 000 ems only.

0.5 In case of capacities not listed, appropriate values may have to be derived from the tables given in this standard (see 5.6). Similarly, in case the coefficient of cubical thermal expansion of the glass of a vessel is known to differ from those used in the tables over the temperature range of 5 to 40°C and the temperature of water is far removed from 27”C, it may be necessary to make an adjustment when working to the limit of accuracy and this may be done by interpolation (see 5.7).

3

Page 8: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

0.5.1 In case it is necessary to compute capacity of a vessel or volume delivered by it at the standard reference temperature of 2O”C, suitable correction has to be applied to the value obtained for 27°C (see 5.8).

0.6 In the preparation of this standard, assistance has been derived from the revised fifth draft IS0 proposal for ‘Method of verification and use of volumetric glassware’ issued by the Secretariat of ISO/TC48/SCl - Volu- metric Glassware of the International Organization for Standardization (ISO) ; BS 1797: 1968 ‘Tables for use in the calibration of volumetric glassware’, issued by the British Standards Institution; and data provided by the National Physical Laboratory (CSIR), New Delhi.

0.7 In reporting the results of a test made in accordance with this standard, if the final value, observed or calculated, is to be rounded off, it shall be done in accordance with IS : 2-1960*.

1. SCOPE

1.1 This standard prescribes tables for calibration and method of verification of volumetric glassware by gravimetrically determining capacities in cubic centimetres at the Indian Standard Reference Temperature 27”C, using distilled or deionized water or pure, dry mercury over the temperature range of 5 to 40°C.

2. TERMINOLOGY

2.1 For the purpose of this standard, definitions given in IS : 1382-1961t, in addition to the following, shall apply.

2.1.1 Verzjication - The process by which the conformity of the individual article with the appropriate standard is determined, culminating in the determination of its errors at one or more points.

3. FACT’ORS AFFECTING THE ACCURACY OF VOLUMETRIC GLASSWARE

3.0 General - The sources of error are common to both calibration and verification of volumetric glassware. Therefore, if in the former process every possible attempt is made to reduce these errors to the minimum, in the latter the care needed is dependent upon the degree of accuracy required; when the greatest accuracy is desired, the article should be used, as nearly as possible, in the manner in which it is verified.

3.1 Temperature 3.1.1 Temperature of VesseZ - The capacity of a glass vessel varies with

the change of temperature depending on the coefficient of cubical thermal expansion of glass of which it is made. The coefficient of cubical thermal expansion of glass generally used for the manufacture of volumetric glassware falls in the range approximately 10 x 10-6/oC and 30 x lo-61°C.

*Rules for rounding off numerical values (revised). fGlossary of terms relating to glass industry.

4

Page 9: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

NOTE- It follows that the standardization temperature is of little importance in the use of a vessel. A vessel made of glass having coefficient of cubical thermal expansion 30x lo-s/Y2 and calibrated at 27°C but used at ZO”C, would, at the temperature of use, show an extra error of only 0.02 percent which is much smaller than the tolerance that 1s prescribed on capacities of most volumetric glassware. But at the same time it is im- portant to specify a standard reference temperature in order to provide a sound basis of calibration or verification of a vessel.

3.1.2 Temperature of Liquid - The coefficient of cubical thermal expansion of the liquid, which is measured, is much greater than that of glass. The coefficient for water is about 2 x lo-a/%, in the temperature range covered, and that for organic liquids such as alcohol is about IO-s/%.

NOTE - It follows that for calibration and verification of volumetric glassware, the temperature of water, for example, should be measured, and appropriate corrections applied. It means that one should ensure that all solutions used in connection with one another are close to the same temperature (in relation to the accuracy required) at the time of measuring their volumes.

For example, if a pipette, calibrated at any reference temperature, is used to measure out two samples of the same aqueous solution at two temperatures differing by 7”C, the two samples will contain the masses of solute which will differ by about 0.12 percent; and this will show itself in the process of titration as an apparent difference in concentration.

3.2 Cleanliness of Glass Surface - The volume contained in or delivered by a glass vessel depends on the cleanliness of its internal surface. Lack of cleanliness can give rise to errors through a badly shaped meniscus involv- ing two defects, namely, incomplete wetting of glass surface; and a generally increased radius of curvature, due to contamination of the liquid surface reducing the surface tension.

3.2.1 In vessels used for delivering, lack of cleanliness can cause additional errors due to the film of liquid on the walls being irregularly distributed or incomplete.

NOTE - In use. as distinct from calibration or verification. chemical contamination can introduce an error even though it has no influence on the accuracy of volume measure- ment. Therefore, where vessels are fitted with ground stoppers, special care should be taken to cleaning the ground zone.

3.2.2 To ascertain whether a piece of glass apparatus is satisfactorily clean, it should be observed during filling. A delivery vessel should pre- ferably be filled from below the meniscus. The rising liquid meniscus should not change shape; that is, it should not crinkle at its edges. After over-filling and withdrawing a little liquid (through the jet in the case of a delivery vessel and by means of a drawn-down glass tube in the case of content vessel) the surface of the glass above should remain uniformly wetted and the meniscus should not crinkle at its edges. Additionally, an experienc- ed operator can recognize the shape of an uncontaminated meniscus, in relation to its diameter.

3.2.3 A suitable method of cleaning volumetric glassware is described in 5.1.1.

5

Page 10: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

3.3 Setting of Meniscus - In this standard two methods of setting the meniscus have been included. In one, the plane of the top edge of the graduation line and in the other the plane at the centre of the graduation line, is the reference plane. If the two methods are used indiscriminately an error will be made equivalent to the volume occupied by a cylinder having a height equal to half the thickness of the graduation line and a cross-section equal to that of the article at the graduation line. The error is not signifi- cant except for work of greatest accuracy; in the case of certain flasks, for example, it may amount to about one-half the Class A tolerance on capa- city if the graduation line is thick. Therefore, in the case of vessels such as volumetric flasks and one-mark pipettes where volume measurement is made by a single meniscus setting, the method of setting meniscus may be stated, and carried out in the way generally used in the country for which the article is meant, particularly for Class A volumetric glassware.

NOTE - In case of vessels such as burettes where the volume is measured, by difference no error is incurred provided that a consistent method of setting the meniscus is adopted.

3.3.1 To make an accurate setting of the meniscus, the lighting should be arranged so that the meniscus appears dark and distinct in outline. For this purpose it should be viewed against a white background and shaded from undesirable illumination. This can be achieved, for example, by securing a strip of black paper round the vessel, not more than 1 mm below the level of the setting, or by using a short section of thick black rubber tubing cut open at one side and of such a size as to clasp the tube firmly.

3.3.2 Parallax is avoided in both methods of setting the meniscus when the graduation lines are of sufficient length to be seen at the front and back of the vessel simultaneously. On apparatus provided with graduation lines on the front only, parallax can be made negligible when making a setting on the top edge of the line by using the black shading strip, taking care that the top edge of this is in a horizontal plane. In this case the eye should be placed so that the front and back portions of the top edge appear to be coincident.

3.4 Time of Delivery - For articles used for delivery of a liquid, the volume delivered is always less than the volume contained due to the film of liquid left on the walls of the vessel. The volume of this film depends on the time taken to deliver the liquid, and the volume delivered decreases with decreasing delivery time. Therefore, such a vessel can deliver a particular volume for only one value of the delivery time. The shorter the delivery time, the greater is the variation in the volume delivered due to the small variations in delivery time which inevitably occur. Provided that the delivery time is never less than a certain value, the volume of the residual film is sufficiently small to ensure that departures from the nominal delivery time which occur in practice have a negligible effect on the volume delivered and that drainage occurring after delivery is negligibly

6

Page 11: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

small. The same effect may be achieved by splitting time into a reasonably shorter delivery time and a definite waiting time.

3.4.1 It follows that the jet should not be interfered with. Any alteration of the jet in order to increase the speed ofdelivery will cause the scale readings to be in error as well as decrease the consistency of reading, Delivery time ranges should, therefore, be specified so that no reasonable differences in volume will appear if the actual delivery time varies in that range on account of, for example, traces of dust.

3.4.2 Nevertheless as a safeguard, the delivery time is often marked on, burettes and pipettes made to Class A tolerances to enable the user to check whether the jet has become blocked or damaged, by measuring the delivery time for himself and comparing his result with the marked delivery time. This inscription is required by legal metrology in some countries.

4. TABLES FOR CALIBRATION OF VOLUMETRIC GLASSWARE

4.0 General-These tables relate to vessels made of glass having coeffi- cients of cubical thermal expansion (a) as follows:

10 x 10-6/“C for Tables IA, 3A and 4A 15 x 10-6/“C for Tables lB, 3B and 4B 25 x 10-6/oC for Tables IC, 3C and 4C 30 x 10-G/“C for Tables lD, 3D and 4D

NOTE - These values have been adopted in accordance with the agreement reached in the eighth meeting of ISO/TC48 in October 1962 and the ninth meeting in June 1964.

4.1 Scope of Operations - Each set of these tables is appropriate to the following operations :

a) Conversion of the observed mass, in grams, in air of average density, of the pure water contained or delivered by a glass vessel at a known temperature to the capacity in ems of the vessel at 27°C (see Tables lA, lB, 1C and 1D).

b) Correction for the departure of the effective air density from the average air density assumed in Tables 1A to ID (see Table 2).

NOTE 1 -The correction from Table 2 need only be applied when high accuracy is desired. The values given shall apply to vessels made of any glass.

NOTE 2 -Table 2 has been formulated for use in conjunction with air pressure measurements made in terms of the commonly used conventional millimetres of mercury, mmHg (1 mmHg is the pressure exerted by a column of mercury 1 millimetre high where gravity is 979.138 7 cm/s”* and the mercury has a density of 13.595 1 g/cm3 at 0°C. Con- version to the SI unit of pressure, Newton per square metre (N/m2) or its multiple, the bar, involves the following relationship:

(1 mmHg=133~115N/m2=0*001 33 115 bar).

c) Conversion of the observed mass of mercury in grams, in air of average density, contained in or delivered by a glass vessel at a

*See IS1 Bul; Gl 18, No. 10, I? 461.

7

Page 12: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

known temperature to the capacity of the vessel in ems at 27°C (see Tables 3A, 3B, 3C and 3D).

d) Conversion of the nominal capacity of a glass vessel in cm3 at 27°C to the mass, in air of average density, of mercury contained or delivered by it at various temperatures (see Tables 4A, 4B, 4C and 4D).

4.2 Basis of Tables

4.2.0 General-The tables take into account the current density of the liquid, change of capacity of the vessel with temperature and the buoyancy of air during weighing. The full basis of the tables is given below.

4.2.1 Tables IA, lB, lC, ID and 2 -Calibration with Water -When weigh- ing a quantity of water at PC, equilibrium is expressed by

M- MU - = Vtpt- vt’ta

n

where M= a AZ

apparent mass in g of the water in air, density in g/cm3 of the air at the time of weighing, density in g/cm3 of the material of which the weights are made,

v, = volume in ems of the water, and pt = density in g/cm3 of the water.

If < = coefficient of cubical thermal expansion of the glass of the vessel (per degree Celsius), the capacity of the vessel at 27°C’ V2,, is given by

v,, = Vt/{l S.c(t-Wl

Hence if C is the correction to be added to M to obtain V..,,

C = V,,-M, or

c = +v,, [ 1 _ {I+< (t-271 (pt--a) n

n-0 1 . .

4.2.1.1 Tables IA, lB, IC and ID are based on expression (3) with the assumption of an average value of o (see below). When the air density is not D but ol , it can be seen from (3) that the small additional correction c required is:

c = v,, ( 1+ < (t-27)] n f*? - !3}

=&, i 1 + 4t - 278 (/_($(aPt) al) (ul -u)

8

Page 13: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

which without significant loss of accuracy, since c is very much smaller than C, reduces to

c= + v,, (l - +-) (01 -u) . .

4.2.2 Tables Sand 4 -Calibration with Mercury - From equation ( 1), where the liquid is now mercury,

vt =M (1 - 2) /(pt - u)

and therefore from equation (2))

Ir,,=M ( 1 - %) / h - 0) 11 + % (t - 2711

that is, as a very close approximation,

v,, = M Pt

l- -g,++--) 11 - o( (t - 27)l *a (5)

=MF

where

I-$+:) Pt 11 - *. (t - WI/P,.

4.2.2.1 Tables 3A, 3B, 3C and 3D give values ofF and Tables 4A, 4B, 4C and 4D reciprocals of F.

4.3 Numerical Data-The numerical data used in the preparation of these tables is as follows:

a) pt =

b)a I=

c) ur =

Density. In the case of water the values relate to distilled water and are based on Chappius’ data as recalculated by Tilton and Taylor (N.B.S. Research Paper RP 971, p 213, part of J. Res. N.B.S., 18, 1937). As the figures given by Tilton and Taylor are in terms of g/ml (taking the 1901 definition of the ‘litre’) they are divided by 1.000 028 to convert to g/ems. In the case of mercury, the values used are based on the mean value of 13.528 727 g/cm3 at 27°C determined by Cook (1961; Phil. Trans. Roy. Sot. A., 254, 125) and the expansion formula of Beatie et al (1941, Proc. Amer. Acad. Arts. Sci., 71, 37 1) ; 0.001 167 g/cm3 (that is, where p=760 and t=27 in the formula given below) ; (OXO~’ 290 75/+0~000 244Oh)/760 (I.000 028) (1+0.003 67t)

a;

9

Page 14: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

where

P=

h=

i;;metric pressure in mm of mercury (mmHg),

vapour pressure of water mm of mercury corres- ponding to the temperature t”C. The air is assumed to be semi-saturated with water vapour and to contain 0.04 percent COs by volume;

d) n = 8.4 g/cm3. This value applies to plain or plated brass weights and those of nickel-chromium (80 percent Ni, 20 percent C?). Stainless steel weights (8.0 g/cm3.) may be used without significant error; and

e) L = 10 x 10-6/0C for Tables IA, 3A and 4A 15 x 10-6/“C for Tables lB, 3B and 4B 25 x 10-6/“C for Tables lC, 3C and 4C ~OX~IO-~/~C for Tables ID, 3D and 4D.

5. VERIFICATION AND USE OF TABLES

5.0 General - Verification is carried out gravimetrically using distilled or deionized water (see IS : 1070-1977”) or pure dry mercury.

5.1 Procedure

5.1.1 Cleaning of Volumetric Glassware - Remove obviously loose con- tamination mechanically from the vessel by brushing, shaking with water

s($table solvdnts i necessary containing pieces of filter paper). Remove oil or grease by

Nearly fill the vessel with an aqueous solution of a soapless detergent, and shake vigorously. Then repeatedly rinse with tap water until traces of the detergent are removed. Finally rinse with distilled or deionized water. Verify in the way described in 3.2.2 that the walls of the vessel are clean.

5.1.1.1 If the walls are not satisfactorily clean after the above treatment fill the vessel with a mixture of equal parts by volume of saturated solution of potassium dichromate and concentrated sulphuric acid, and allow to stand for several hours. Take care that the acid does not come in contact with the outside of the vessel, unless it is known that the filling of the gradua- tion marks is resistant to it. Rinse the vessel again with tap water until traces of acid are removed. Finally rinse with distilled or deionized water and again verify that the walls are clean; if they are not, repeat the procedure.

5.1.1.2 After cleaning, rinse the vessel, adjusted to contain, with ethyl alcohol and dry with clean air at room temperature. Alternatively, if the vessel is not required for immediate use, it may be kept filled with distilled or deionized water. It is not necessary to dry a vessel marked ‘TO DELIVER’.

*Specification for water for general laboratory use (second revision).

10

Page 15: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

5.2 Procedure Based on the Use of Water - Accurately weigh the vessel to be verified, or a weighing bottle, if the vessel is intended for delivery, that is, to a precision better than 10 percent of the tolerance laid down.

5.2.1 Make sure that the vessel or weighing bottle and water are at room temperature and that the water is not contaminated by grease used in stopcocks, etc, or by a residue of the material used for cleaning and/or drying the walls of the vessel.

5.2.2 Fill the vessel, adjusted to contain, with distilled or deionized water, to a distance of a few millimetres above the graduation line to be tested, and make the final setting of the meniscus to the line by withdrawing the surplus water by means of a glass tube drawn-down to a jet or in the case of pipettes adjusted to contam, by means of filter paper. Alternatively, wet the walls of the vessel completely for a considerable distance above the ’ graduation line to be tested. Fill the vessel to a few millimetres below the graduation line by running water down the wetted wall of the neck. Observe two minutes drainage time and then make the final setting by discharging the required water against the wall about one centimetre above the graduation line and rotating the vessel to re-wet the wall uniformly.

5.2.3 Clamp the vessel, adjusted to deliver, in a vertical position and fill to a few millimetres above the graduation line to be tested; remove any liquid remaining on the outside of the jet. Then make the setting by running out the surplus water through the jet. Remove any drop of liquid adhering to the jet by bringing an inclined glass surface into contact with the tip of the jet. Deliver water into the tared weighing bottle with the flow unrestricted.

5.2.4 Weigh the filled vessel or the weighing bottle to the same accuracy as in 5.2 and measure the temperature of the water using a thermometer accurate to O*l”C’(see Schedule Mark 22 of IS : 4825-1968*) by inserting it in the filled vessel or the weighing bottle, after weighing.

5.3 Procedure Based on the Use of Mercury - Pure, dry mercury may be used for vessels of small capacity, following the procedure detailed in 5.2, and also keeping in view the physical properties of the two liquids.

5.4 Calculation

5.4.1 The difference between the results of the first (5.2) and the second (5.2.4) weighings is the mass of water contained in or delivered by the vessel under verification. In order to obtain the volume at the standard reference temperature 27°C from this mass of water take a figure, appro- priate to the measured temperature of water (5.2.4) and the coefficient of cubical thermal expansion of glass of which the vessel is made, from Tables lA, lB, IC or 1D as the case may be.

*Specification for laboratory and reference thermometers.

11

Page 16: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

5.4.1.1 Take an additional figure from Table 2, as appropriate, to allow for the departure of the actual density of air from the average (see 5.5.1).

5.4.2 In order to obtain the volume at the standard reference tempera- ture 27°C from the mass of mercury contained in or delivered by the vessel, multiply this value by the factor, appropriate to the measured temperature of mercury and the coefficient of cubical thermal expansion of glass of which the vessel is made, from Tables 3A, 3B, 3C or 3D as the case may be (see 5.5.2).

5.4.2.1 In order to verify a result obtained by using mercury, multiply the value by the factor, appropriate to the measured temperature of mercury and the coefficient of cubical thermal expansion of glass of which the vessel is made, from Tables 4A, 4B, 4C or 4D (see 5.5.3).

5.5 Examples for Use of Tables

5.5.1 Test fir a 1000 cm3 Vessel with Distilled or Deionized Water - Suppose the glass of the vessel is the coefficient of cubical thermal expansion of

10 x 10-s/OC; and

99644 (+)3*20 (Table lA/l 000)

( +)O.O 1 (Table 2/ 1 000)

1 000*05 cm3

Mass of water in grams Temperature of water = 21.5°C :. C 1 Ambient temperature = 21.5% Pressure, mmHg = 750 .‘. c =

. . . Capacity of vessel at 27°C zz

5.5.2 Test for a 10 cm3 Vessel with Mercury - Suppose the coefficient of cubical thermal expansion of the glass of the vessel is 30 x 10V6/“C; and

Mass of mercury in grams = 135.57 Temperature of mercury= 15°C So the multiplying factor at 15°C to

convert mass of mercury in air into capacity of vessel at 27°C = 0.073 779 (Table 3D)

* . . Capacity of vessel at 27°C = 10.002 2 cm3

5.5.3 Graduation of a 5 mm3 Vessel Using Mercury - Suppose the coefficient of cubical thermal expansion of the glass of the vessel is 10 x 1O-6/“C; and

Nominal capacity of the vessel at 27°C = 5 cm3 Multiplying factor to convert nominal

capacity at 27°C into required mass in air of the mercury at 15°C = 13.557 (Table 4A)

* . . Mass in air of mercury at 15°C = 67.785 g

12

Page 17: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

5.6 Correction for Capacities not Listed in the Tables - Values for vessels of capacities not listed in the tables may be derived by proportion from appropriate tables. For many capacities this may be done simply by moving the decimal point; for example, values for capacity 0.7 cm3 for a vessel made of glass having coefficient of cubical thermal expansion 10x lo-6/“C, may be derived from Tables lA/70 and 2/70 respectively by moving the decimal point to the left by one place.

5.7 Correction for Glass Having Intermediate Coefficient of Cubical Thermal Expansion - When the coefficient of cubical thermal expansion of the glass of the vessel over the temperature range of 5 to 40°C is known to differ from that used in the tables and the temperature of water is far removed from 27”C, it may be necessary, when working to the limit of accuracy, to make an adjustment. A comparison of the corresponding entries for the appropriate capacity and temperature in tables for various glasses will indicate the effect of the difference between the coefficients of cubical thermal expansion 10 x 10e6 and 30 x 10q6 per degree Celsius. If this shows that an adjustment would be significant, the correction appro- priate to the glass concerned may be obtained by linear interpolation between the two entries.

5.8 Correction for Standard Reference Temperature of 20°C - When it is necessary in cold countries to work at an ambient temperature con- siderably below 27”C, and these countries do not wish to use the standard reference temperature of 27X, it is recommended that they should adopt a temperature of 20°C.

5.8.1 The effect of lowering the temperature of a soda glass vessel from 27 to 20°C is to decrease its capacity by about 1 part in 5 000, and is negligible for most types of volumetric glassware. Where such effect is significant, the capacity of a vessel at 20°C may be obtained from its capacity at 27°C by subtracting the following depending upon the coefficient of cubical thermal expansion:

Coejkient of Cubical Correction Applicable per Thermal Expansion of Cubic Centimetre Volume of

Glass Vessel the Vessel

10 x lo-6/OC (-) 0.000 070 cm3 15 x IO-6/“C (-) 0.000 105 cm3 25 x 10-6/oC (-) 0.000 175 cm3 30 x 1 O-6/% (-) 0.000 210 cm3

Thus the correction for a 1 000 ems vessel made of glass having a coeffi- cient of cubical thermal expansion 10 x 10-6/“C is -0.07 ems. This correc- tion is, of course, applied after the capacity at 27°C has been obtained by the application of the corrections in the appropriate Tables 1A to ID and Table 2, or the factor given in Tables 3A to 3D.

13

Page 18: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

5.8.2 With regard to Tables 4A to 4D, the mass of the mercury contained or delivered at PC by a vessel of capacity 1 cm3 at 20°C may be obtained by adding to the tabulated mass of mercury the following values :

CoeJcient of Cubical Thermal Expansion of

Correction Applicable per

Glass Vessel Cubic Centimetre Volume of

the Vessel

10 x lo-6/“C 0.001 15

g x lo-6/OC 0.001 5

25 10-6/“C g

x 0.002 5 30 x lo-6/OC

g 0.003 g

14

Page 19: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE IA/5

NOMINAL CAPACITY 5 cma

(Coefficient of cubical thermal expansion of glass 10 x 10--B/oC) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C.

TEMPERATURE OF WATER

PC

5

6 7

t 10

1

0.001 3

0.001 3 0.001 3 0.001 4 0.001 4 0.001 5

0.001 6 0.001 7 0.001 8 0.001 9 0.002 0

0.002 2 0.002 4 0.002 5 0.002 7 0.002 9

0.003 1 0.003 3 0.003 5 0.003 8 0.004 0

0.004 3 0.004 5 0.004 8 0.005 1 0.005 3

0.005 6 0.005 9 0.006 3 0.006 6 0.006 9

o.od7 3 0.007 6 0.008 0 0.008 3 0.008 7

NOMINAL CAPACITY, cd

2

0.002 6 0.003 9 0.005 1 0.006 4

0.002 6 0.003 9 0.005 2 0.006 5 0.002 7 0,004 0 0,005 3 0.006 6 0.002 7 0.004 1 0.005 5 0.006 8 0.002 9 0.004 3 0.005 7 0.007 1 0.003 0 0.004 5 0.006 0 0.007 5

0,003 2 0.004 7 0,006 3 0.007 9 0.003 4 0.005 0 0.006 7 0.008 4 0.003 6 0.005 4 0.007 2 0.009 0 0.003 8 0.005 7 0.007 7 0.009 6 0.004 1 0.006 1 0.008 2 0.010 2

0,004 4 0.006 6 0,008 8 0,011 0 0.004 7 0.007 1 0.009 4 0.011 8 0.005 0 0.007 6 0.010 1 0.012 6 0.005 4 0,008 1 0.010 8 0.013 5 0.005 8 0,008 7 0.011 6 0,014 5

0.006 2 0.009 3 0.012 4 0.015 5 0.006 6 0.009 9 0.013 2 0.016 5 0,007 1 0.010 6 0.014 1 0.017 6 0.007 5 0,011 3 0.015 0 0,018 8 0.008 0 0.012 0 0.016 0 0.020 0

0.008 5 0.012 8 0.017 0 0.021 3 0.009 0 0.013 5 0.018 1 0.022 6 0,009 6 0.014 3 0.019 1 0.023 9 0.010 1 0.015 2 0.020 2 0.025 3 0.010 7 0.016 0 0.021 4 0.026 7

0.011 3 0.016 9 0.022 6 0.028 2 0.011 9 0.017 8 0.023 8 0.029 7 0.012 5 0.018 8 0.025 1 0.031 3 0.013 2 0.019 8 0.026 3 0.032 9 0.013 8 0.020 7 0.027 7 0.034 6

0.014 5 0.021 8 0.029 0 0.036 3 0.015 2 0.022 8 0.030 4 0.038 0 0.015 9 0.023 9 0.031 8 0.039 8 0.016 6 0.024 9 0.033 2 0.041 6 0.017 4 0.026 0 0.034 7 0.043 4

3 4 5

E~MPERATuRE OF WATER

tot

5

::

:9 15

16 17

:9” 20

;; 25

36 37

3: 40

15

Page 20: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE IA/6 NOMINAL CAPACITY 6 cm3

(Coefficient of cubical thermal expansion of glass 10 x 10-B/OC) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2 /6).

TEMPERATURE OF WATER

tot

5 0.008 0,008

f

: 10

0.008 0.008 0.008 0.008 0.008 0.008 0.009 0.009 0.009 0.009

:: 13

:“;

0.009 0.010 0.011 0.011 0.012

0.010 0.010 0.011 0.012 0.013

:f 18

:t

0.013 0.014 0.014 0.015 0,015 0.016 0.016 0,017 0.017 0,018

0.019 0.020

0.019 0.020

8-O 0’5

TEMPERATURE OF WATER

0,021 0.022 0.023 0.023 0.024 0,025

0,026 0,026 0.027 0.028 0.029 0.030 0.030 0.031 0.032 0,033

0.034 0.035 0.036 0,037 0.038 0.039 0.040 0.040 0.041 0.042

0.044 0.045 0.046 0.047 0.048 0.049 0.050 0.051 0.052 0.053

TABLE 2/6 NOMINAL CAPACITY 6 cm3

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

TEMPERATURE OF AIR, “C 730

5 0.000

10 0.000

15 0.000

20 0.000

25 0.000

30 0.000

35 0.000

40 -0~001

-

__

-

740 750 760 770 780 790

0.000 0~000 +0.001 t_O~OOl +0.001 +0.001

0~000 0~000 0.000 0~000 +0.001 +0.001

0.000 0~000 0.000 0.000 0.000 +0,001

0.000 0~000 0.000 0.000 0.000 0.000

0~000 0.000 0.000 0.000 0.000 0.000

0~000 0.000 0.000 0.000 0.000 0.000

0.000 0.000 0.000 0.000 0.000 0.000

0.000 0.000 0.000 0.000 0.000 0.000

PRESSURE OF AIR IN mmHg

16

Page 21: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/? NOMINAL CAPACITY 7 ems

(Coefficient of cubical thermal expansion of glass 10 x lo-s/‘C) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/7).

TEMPERATURE OF WATER T tot

5

f 8

1:

:: 13 14 15 16 17 18 19 20

z: -

8-O 0.5 _-. 0,009 0,009 0.009 0,009 0.009 0.009 0.010 0.010 0.010 0.010 0.010 0.011 0,011 0.011 0.012 0.012 0.013 0.013 0,013 0.014 0.014 0.015 0.015 0.016 0.016 0.017 0.018 0.018 0.019 0.020 0.020 0.021 0.022 0.022 0.023 0,024

TEMPERATURE OF AIR, “C

5

10

15

20

25

30

35

40

__

-7

-

-- . -

-

TEMPERATURE OF WATER -

O-0 05

0.025 0,025 0.026 0.027 0.028 0,029 0.030 0.031 0.032 0.033 0.033 0.034 0.035 0.036 0.037 0.038

0.040 0.041 0.042 0.043 0.044 0.045 0.046 0.047 0,048 0,050

0.051 0.052 0.053 0.054 0.056 0.057 0.058 0.059 0.061 0.062

TABLE 217 NOMINAL CAPACITY 7 cm3

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

-

730

0.000

0.000

0.000

0.000

0.000

0.000

0.000

-0~001

-

-7

-

740

0.000

0~000

0.000

0.000

0.000

0.000

0.000

-0~001

-

.-_

-

PRESSURE OF AIR IN mmHg

750

+0.001

0.000

0.000

0.000

0.000

0.000

0~000

0.000

17

-

--

-

760

$0.001

0~000

0.000

0.000

0.000

0.000

0.000

0.000

770

$-o~ool

+o~ool

0.000

0.000

0.000

0~000

0.000

0.000

-

-_

-

780

t_O~OOl

+0.001

+0.001

0.000

0.000

0.000

0.000

0.000

-

-_ 790

+-0.001

+0.001

+o~ool

0.000

0.000

0.000

0.000

0.000

Page 22: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE IA/8 NOMINAL CAPACITY 8 ems

(Coefficient of cubical thermal expansion of glass 10 x 10-s/%) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/8).

TEMPERATURE OF WATER

t”C 5

f

f 10

:: 13

:: 16 17 I8

:t

z:

0-O

0.010 0.010 0.011 0,011 0.011 0.012 0.013 0.013 0.014 0.015 0.016 0.018 0.019 0.020 0.022 0.023 0.025 0.026

0’5

0.010 0,010 0.011 0.011 0.012 0,012 0.013 0.014 0.015 0.016 0.017 0.018 0.019 0.021 0.022 0.024 0.026 0.027

TEMPERATURE OF WATER

tot 0.0

0.028 0.030 0.032 0.034 0.036 0,038 0.040 0.043

0.045 0.048 0.050 0.053 0.055 0.058 0,061 0.064 0.066 0,069

TABLE 2/g

NOMINAL CAPACITY 8 cm3

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

T 0.5

0.029 0.031 0.033 0.035 0,037 0.039 0.042 0.044

0.046 0.049 0.051 0,054 0.057

0.059 0.062 0,065 0.068 0.071

TEMPERATURE OF AIR, “C

5

10

15

20

25

30

35

40

730

0.000

0.000

0.000

0.000

0.000

0.000

-0~001

-0~001

PRESSURE OF AIR IN mmHg

740

0~000

0.000

0.000

0.000

0.000

0.000

0.000

-0~001

750 760

+0.001

0.000

0~000

0.000

0.000

0~000

0.000

-0~001

+o~ool

+0.001

0.000

0.000

0.000

0.000

0.000

0~000

18

770

+o~ool

+0.001

0.000

0.000

0~000

0.000

0.000

0.000

780

+0.001

+o~ool

+o~ool

0.000

0~000

0.000

0.000

0.000

790

+o~ool

+0,001

+0.001

+0,001

0~000

0~000

0~000

0~000

Page 23: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/9

NOMINALCAPACITY9cms

(Coefficient of cubical thermal expansion of glass 10 x 10-s/OC) Add to mass (grams) of pure water at t°C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/9).

TEMPERATURE OF WATER

0.0

0.012

0.012 0.012 0.012 0.013 0,013

0.014 0,015 0,016 0.017 0.018

0.020 0.021 0.023 0,024 0.026

0.028 0.030

TEMPERATURE OF AIR, “C

5

10 15

20

25

30

35

40

0.5

0,012

0:012 0.012 0,013 0.013 0.014

0.015 0.016 0.017 0.018 0,019

0.020 0.022 0.023 0.025 0.027

TEMPERATURE OF WATER

0.032 0,034 0.036

0.038 0.041 0.043 0.046 0.048

0.051 0.054 0.056 0.059 0.062

0.065 0.068 0,072 0.075 0.078

TABLE 219

NOMINAL CAPACITY 9 cma

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

0.0 0.5

o.oi3: ’ 0.035 0.037

0.039 0.042

8% 0.049

0.052 0.055

;:g; 0.064

0.067

8:;:; 0.076 0.080

T

730

0.000 0.000 0.000

0.000 0~000

0.000 -0~001 -0~001

740

+0.001

0.000

0.000

0.000

0.000

0.000

-0~001

-0~001

PRESSURE OF AIR IN mmHg

750

+0.001

0.000 0.000 0.000 0.000 0.000

0.000 -0~001

760

+0.001 +0.001

0.000

0.000

0.000

0.000

0.000

0.000

770

+0.001

+0.001

+0.001

0.000

0~000

0.000

0.000

0~000

780

3_0~001 +0.001 -t-o*001

0.000

0.000

0.000

0.000

0.000

790

30.001

+o~ool

+o~ool

+0.001

0.000

0.000

0.000

0.000

19

Page 24: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/lO

NOMINAL CAPACITY 10 cma

(Coefficient of cubical thermal expansion of glass 10 x lo-s/X) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table Z/IO).

TEMPERATURE OF W‘ 4TER

1°C --

5

0’0

5

10

15

20

25

30

35

40

0.013 0.013

0.013 0,013 0.014 0.014 0.015

00:;:; 0.014 0.015 0.015

0,016 0.016 0.017 0.017 0.018 0.019 0.019 0.020 0.020 0.021

0,022 0,023 0.024 0.024 0,025 0.026 0.027 0.028 0.029 0.030

0.031 0.032 0033 0.034

o-5

-i TEMPERATURE OF WATER

0.0 0.5

0,035 0.036 0.038 0.039 0.040 0.041

0,043 0.044 0.045 0.046 0,048 0.049 0.051 0.052 0.053 0,055

0.056 0.058 0,059 0.061 0.063 0.064 0.066 0.067 0.069 0.071

0.073 0.074 0.076 0.078 0.080 0.081 0.083 0.085 0.087 0.089

TABLE 2/10

NOMINAL CAPACITY 10 cm3

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

I PRESSURE OF AIR IN mmHg

730 740 750 760 770

0.000 +0.001 $0~001 +0.001 +o~ool

0.000 0.000 +0*001 +0.001 _tO.OOl

0.000 0.000 0.000 0.000 +0.001

0.000 0.000 0~000 0.000 0.000

0.000 0.000 0.000 0~000 0.000

-0~001 0.000 0.000 0.000 0.000

-0~001 -0~001 0.000 0.000 0.000

-0~001 -0~001 -0~001 -0~001 0.000

780

+0.001

+o~ool

+0.001

+0.001

0.000

0.000

0.000

0.000

790

+0.001

t_0,001

10.001

+0.001

0.000

0.000

0.000

0.000

Page 25: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/ll NOMINAL CAPACITY 11 cm3

(Coefficient of cubical thermal expansion of glass 10 x 10-s/%) Add to mass (grams) of pure water at t°C to obtain capacity of vessel at 27°C

(in conjunction with Table 2 /I 1).

TEMPERATURE OF WATER

tot 5

f

! 10 11 12 13

:s

:;

:t 20

::

TEMPERATURE OF AIR, “C

5

10

15

20

25

30

35

40

0’0

0.014 0.014 0.014 0.014 0.015 0,015 0.015 0.015 0.016 0.016 0.016 0.017 0.017 0.018 0.018 0.019 0.020 0.020 0,021 0.022 0.023 0.023 0.024 0.025 0.026 0.027 0.028 0.029 0.030 0.031 0.032 0.033 0.034 0.035 0.036 0.038

0.5

i TEMPERATURE OF WATER

O-0

0.039 0.040 0,041 0,043 0.044 0.045 0.047 0.048 0.050 0,051 0.053 0.054 0.056 0.057 0.059 0.060

0.062 0.064 0.065 0.067 0.069 0.071 0.072 0.074 0.076 0.078

0.080 0.082 0.084 0.086 0.087 0.089 0.091 0.093 0.095 0.098

TABLE 2/11

NOMINAL CAPACITY 11 cm3

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

T O-5

730

0.000

0~000

0.000

0.000

0.000

-0~001

-0~001

-0~001

PRESSURE OF AIR IN mmHg

740

+0.001

0.000

0.000

0.000

0.000

0.000

-0~001

-0~001

750

+0.001

+0.001

0.000

0.000

0.000

0.000

0.000

-0~001

21

760

+o~ool

+o~ool

+0.001

0.000

0.000

0.000

0.000

-0~001

770

+0.001

+0.001

$0.001

0.000

0.000

0.000

0.000

0.000

780

+0.001

$0~001

+0.001

+0.001

0.000

0.000

0.000

0.000

790

+0.001

+0.001

+0.001

+0.001

+0.001

0.000

0.000

0.000

Page 26: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/15

NOMINAL CAPACITY 15 ems

(Coefficient of cubical thermal expansion of glass 10x 10-s/“C) Add to mass (grams) ofpure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/ 15).

TEMPERATURE OF WATER

tot 5 6

x

1:

:: 13

it

if 18 19 20 21 22

8-O 0.5

0.019 0.019

0.019 0.020 0.020 0.020 0.021 0.021 0.021 0.022 0.022 0.023

0.024 0.024 0.025 0,026 0.027 0.028 0.029 0.030 0.031 0,032

0.033 0.035 0.038 0.041 0.043

0.046 0.050

0.034 0,037 0.039 0.042 0.045

0.048 0.051

T TEMPERATURE OF WATER

0-O 0.5

0.053 0,056 0.060 0.064 0.068 0,072 0.076 0,080

0.085 0,089 0.094 0,099 0.104

0,109 0.114 0.119 0,125 0.130

0.055 0.058 0.062

0.066 0.070 0.074 0.078 0.082

0.087 0.092

“,:y;;

0.106

0.111 0.117 0.122 0.127 0.133

22

Page 27: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TEMPERATURE OF AIR, “c

5

10

15

20

25

30

35

40

IS: 8897 - 1978

TABLE 2/15

NOMINAL CAPACITY 15 cd

.4llowance for temperature and pressure of air. *4dd (+) to mass or subtract (-) from it.

730

+0.001

0~000

0.000

0.000

-0~001

-0~001

-0~001

-0~001

PRESSURE OF AIR IN mmHg

740

+0,001

_tO~OOl

0.000

0.000

0.000

-0~001

-0~001

-0~001

-

_-

-

750

+o~ool

+0.001

0.000

0~000

0.000

0.000

-0~001

-0~001

760

+0.001

+0.001

+0,001

0.000

0.000

0.000

0.000

-0~001

770

+o~ooz

+0.001

+0.001

+o~ool

0.000

0.000

0.000

-0~001

780

+0.002

+o~ool

+0.001

+0.001

+0.001

0~000

0~000

0.000

790

+0.002

+0.002

+0.001

_tO~OOl

$0.001

0.000

0.000

0.000

23

Page 28: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE IA/20

NOMINAL CAPACITY 20 cm3

(Coefficient of cubical thermal expansion of glass 10 x 10-s/‘%) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table Z/20);

TEMP

WZER 02

0-O O-1

-

-_

I

,

,

,

,

/

,

O-8 o-9

3,026 0.026 0.026 0.026 0.026 0.026 0.026 0.026 0.026 0.026

DO26 0,026 0.026 0.026 0.026 0.026 0.026 0,026 0.027 0.027 0.027 0,027 0,027 0.027 0.027 0.027 D.027 0.027 0.028 0,028 0.028 0.028 0.028 0,028 D.029 0.029 0.029 0,029 0.029 0.029 0,029 0.03a 0.030 0.030 0.030 0,030 0.031 0.031 0.031 0.031

0.026 0,026 0.027 0.027 0.028 0.028 0.030 0.030 0,031 0,031

0.032 0,032 0.032 0.032 0.032 0.033 0.033 0.033 0.034 0.034 0,034 0,034 0.034 0.035 0.035 0,035 0.036 0.036 0.036 0,037 0.037 0.037 0.037 0.037 0.038 0.039 0.039 0.039 0,039 0.040 0.040 0,040 0.041 0.041 0.042 0.042 0.042 0.042 0.043 0.043

0.033 0,033 0.035 0,036 0.038 0.038 0.040 0.041 0.043 0,044

0.044 0.047 0.05c 0,054 0.05E

0.044 0.044 0.045 0.045 0.045 0.046 0.046 0.047 0.048 0.048 0.048 0.049 0.049 0.049 0.051 0,051 0.051 0.052 0.052 0.053 0.053 0.054 0.055 0.055 0.056 0.056 0.056 0.057 0.058 0.059 0.059 0,059 0.060 0.060 0.061

0,046 0.047 0,050 0.050 0.053 0.054 0,057 0.057 0,061 0.061

0.062 0.062 0.063 0.063 0.064 0.064 0.064 0.065 0.066 0.065 0.067 0.067 0,068 0.068 0.069 0.069 0.071 0.071 0.071 0.072 0.072 0.073 0.073 0,074 0.075 0.076 0.076 0.077 0,077 0.078 0.078 0.079 0.08C 0.081 0,081 0.082 0.082 0,083 0.083 0.084

0.065 0.066 0.070 0.070 0.074 0.075 0.079 0.080 0,084 0.085

0,085 0.090 D.096 D.lO1 D.107

0,086 0,086 0.087 0.087 0.088 0.088 0.089 0.091 0.091 0.092 0.092 0.093 0.093 0.094 0.096 0.097 0.097 0.098 0.098 0.099 0.100 0.102 0,102 0.103 0.104 0.104 0,105 0.105 0.108 0.108 0.109 0.109 0.110 0.111 0.111

0.089 0.090 0.095 0,095 0.100 0.101 0.106 0.106 0,112 0.112

3.113 0.114 0.114 0.115 0.115 0.116 0.117 0.117 0.118 0.118 3.119 0.120 0.120 0.121 0.121 0.122 0.123 0.123 0.124 0.125 I.125 0.126 0.127 0.127 0.128 0.128 0.129 0.130 0.130 0.131 I.132 0.132 0.133 0.134 0.134 0.135 0.136 0.136 0.137 0.138 I.138 0.139 0.140 0.140 0.141 0.142 0.142 0.143 0,144 0.144

I.145 0.146 0.146 0.147 0.148 D. 148 0.149 0.150 0.151 0.151 1.152 0.153 0,153 0.154 D.155 3.155 0.156 0.157 0.158 0,158 1.159 0.160 0.160 0.161 3.162 3,163 0.163 0.164 0,165 0.166 1.166 0.167 D.168 $168 3.169 1.170 0.171 0.171 0,172 0.173 1,174 D.174 3.175 3,176 3.177 I.177 0.178 0.179 0.180 0.180

24

-

Page 29: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TEMPERATURE OF AIR, “C

5

10

15

20

25

30

35

40

IS : 8897 - 1978

TABLE 2120

NOMINAL CAPACITY 20 cm3

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

-

I 730

+o~ool

0.000

0.000

0.000

-0~001

-0~001

-0~001

-0~002

740

+0.001

+0401

0.000

0.000

0.000

-0~001

-0~001

-0.002

PRESSURE OF AIR IN mmHg

750

--

+0.001

to.001

+0.001

0.000

0.000

-0~001

-0~001

-0~001

760

+0,002

+0401

+0.001

$0.001

0.000

0.000

-0~001

-0~001

-

_-

-

770

+0,002

+oao2

+0.001

+o~ool

0.000

0.000

0.000

-0~001

780

+0.002

+0,002

+0.001

$0~001

+0.001

0.000

0.000

0.000

790

+0,003

+0.002

+0.002

+0.001

+o~ool

+0.001

0~000

0.000

25

Page 30: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TEMP

WZR f°C

TABLE lA/25

NOMINAL CAPACITY 25 cd

(Coefficient of cubical thermal expansion of glass 10x 10-B/oC) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/25).

o-0 8-I o-2 0.3 o-4 o-5. O-6 0.7 O-8 o-9 TEMP

N%l t-2

0.032 0.032 0.032 3.032 3.032 I.032 I.032 0,032 0,032 0,032 5

0.032 0,032 0,033 0,033 3.033 3,033 I.033 0.033 0.033 0.033 0.033 0.033 0,033 0.033 3.034 3.034 I.034 0.034 0,034 0,034 0.034 0,034 0.034 0.035 3,035 3.035 I.035 0.035 0.035 0,036 0.036 0,036 0.036 0.036 3.036 1.037 I.037 0.037 0.037 0,037 0.037 0.038 0.038 0,038 0,038 3,038 I.039 0,039 0.039 0,039

!

t 10

0.040 0.040 0.040 0.040 D.040 3.041 3.041 0.041 0.041 0.042 0,042 0,042 0.043 0.043 0.043 D.043 3.044 0,044 0.044 0.044 0,045 0.045 0.045 0.046 0.046 0.046 3.047 0.047 0.047 0.048 0.048 0.048 0.048 0.049 0.049 0.049 3,050 0.050 0.050 0,051 0,051 0.052 0,052 0,052 0.053 0.053 3.053 0.054 0.054 0.054

:: 13

:s

0,055 0.055 0.056 0.056 0,056 0,057 3.057 0,058 0.058 0.058 0.059 0,059 0.060 0.060 0.060 0.061 D.061 0.062 0.062 0.063 0.063 0.063 0.064 0.064 0.065 0.065 3.066 0,066 0 067 0.067 0.068 0.068 0.068 0.069 0.069 0.070 3,070 0,071 0,071 0,072 0,072 0,073 0,073 0,074 0,074 0.075 0,075 0.076 0.076 0.077

16 17

:B 20

0.077 0.078 0.078 0.079 0.079 0,080 0.081 0.081 0.082 0.082 0.083 0.083 0.084 0.084 0.085 0.085 0.086 0,087 0.087 0.088 0.088 0.089 0.089 0.090 0.090 0.091 0.092 0,092 0.093 0.093 0.094 0.095 0.095 0.096 0.096 0.097 0.098 0.098 0.099 0.099 0.100 0.101 0.101 0.102 0,103 0.103 D. 104 0.104 0.105 0.106

0.106 0.107 0.108 0.108 0.109 0.110 0.110 0.111 0.112 0.112 0.113 0.113 0.114 0.115 0.115 0.116 0.117 0,118 0.118 0.119 0.120 0.120 0.121 0.122 0.122 0.123 0.124 0,124 0.125 0.126 0.127 0,127 0.128 0.129 0.129 0.130 0.131 0.132 0.132 0.133 0.134 0,134 0.135 0.136 0.137 0.137 0.138 0.139 0.140 0.140

0.141 0.142 0.143 0.143 0.144 0,145 0.14E 0.146 0.147 0.148 0.149 0.150 0.150 0,151 0.152 0.153 0.153 0.154 0.155 0.156 0.157 0.157 0.158 0.159 0.160 0.161 0.161 0.162 0.163 0.164 0.165 0.165 0.166 0.167 0.168 0.169 0.17c 0.17a 0.171 0.172 0,173 0.174 0,175 0.175 0.176 0.177 0.17E 0.179 0.180 0.180

z; 33 34 35

0.181 0.19c

;::E 0.217

0.182 0,183 0.191 0.192 0.200 0.201 0.209 0.210 0,218 0.219

0.184 0.193

;:;y; 0.220

0.185 0,186 0.18E 0.18i 0.188 0.189 0.193 0.194 0.19: 0.19E 0.197 0.198 0.202 0.203 0.204 0.20F 0.206 0.207 0.211 0.212 0,212 0.214 0.215 0.216 0.221 0.222 0.22: 0.224 0,229 0.225

z; 38 39 40

26

Page 31: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TEMPERATURE OF AIR, “C

5

10

15

20

25

30

35

40

IS : 8897 - 1978

TABLE 2125

NOMINAL CAPACI’IY 25 cm3

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

730

+o~ool

+0.001

0.000

0.000

-0~001

-0~001

-0~002

-0ao2

740

+0~001

+0.001

0.000

0.000

-0~001

-0~001

-0~001

-0.002

PRESSURE OF AIR IN mmHg

750

+0,002

+0.001

+0.001

0.000

0.000

-0~001

-0~001

-0.002

760

+0,002

+0.002

+0.001

+0.001

0.000

0.000

-0~001

-0~001

770

+0.003

+0.002

+0,002

+0.001

+0.001

0.000

0.000

-0~001

780

+0.003

+0.002

+0.002

+0.001

+0.001

0.000

0~000

-0~001

790

+0.003

+0.003

+rJ.o02

+0.002

$0~001

to,001

0~000

0.000

27

Page 32: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/30 NOMINAL CAPACITY 30 cm3

(Coeficient of cubical thermal expansion of glass 10x IO-s/‘C) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table Z/30).

TEMP

MJZ t-2

5

::

:: 15

Zf 28 29 30

;: 33 34 35

36

z 39 40

0.03!

0.03! 0.04( 0.04. 0.04: 0.04’

0.04; 0.05( 0.054 0.05; 0.061

0.06t 0.071 0.07t 0.081 0.087

0*09? 0,099 @lot 0.113 0.120

cl.128 cl.135 3.143 3.152 I.160

I.169 I.178 I.188 I.198 I.207

I.218 I.228 I.239 I.249 I.260

0,03!

0.03! 0.04( 0.04: 0.04: 0.041

0.04f 0.051 0.051 0.05E 0.06;

0.06t 0.071 0.07f 0.082 0.087

0.093 0. IOC 0.107 0.114 0.121

0.128 0.136 3.144 3.153 3,161

I.170 I.179 I.189 I.199 I.208

I.219 1.229 I.240 I.250 I.262

0,03!

0.03! 0.04(

8:;;: 0.04;

0.04f 0.051 0.051 0.051 0.06;

0,067 0.07; 0.07; 0.082 0.083

0,094 0. IOC 0.105 0,114 0.122

0.129 t-J.137 3.145 3.154 3.162

I.171 I.180 I.190 I.199 I.209

I.220 I.230 I.241 I.252 I.263

0.03!

0.03! 0.04( 0.04: 0.04: 0.04f

0.04f 0.051 0.05: 0.055 0.06:

0.067 0.072 0.077 0.083 0.089

0.095 0.101 0.108 0.115 0.122

3.130 3.138 I.146 I.154 I.163

I.172 I.181 I.191 I.200 I.210

I.22 1 I.231 j.242 j.253 I.264

0.03!

0.03! 0.04( 0.04: 0.04r 0.04f

0.04s 0.05; 0.05: 0.055 0.062

0.068 0.073 0.076 0.083 0.089

0,095 0.102 D.109 3.116 3.123

I.131 I.139 I.147 I.155 I.164

I.173 I.182 1.192 I.201 I.211

I.222 I.232 I.243 I.254 k265

0.03!

0.03s 0.04( 0.04: 0.04‘ 0.04t

0.041 0.05; 0.05f 0.055 0.064

0.068 0.073 0.073 0.084 0,090

0.096 D. 102 ID.109 3.116 1.124

I.131 I.139 I.148 I.156 I.165

j.174 I.183 I.193 I.202 I.212

I.223 I.233 I.244 I.255 b.266

-

O-6 o-7

0.03: 0.035

0.03: 0.041 0.04; 0.04 0.04f

0.03: 0.041 0.04; 0.044 0.047

0.04: 0.052 0.05t 0.06C 0.064

1 I i

I 1

0.04: 0.052 0.05E 0.06C 0.064

0.065 0.074 0.079 0.084 0.090

0.069 0.074 0.079 D.085 DO91

0.097 0.103 WI10 3.117 I.125

0,097 3.104 3.111 3.118 I.125

3.132 I.140 I.148 I.157 I.166

I.133 I.141 I.149 I.158 I.167

I.175 I.184 I.194 j.203 j.213

I.176 I.185 j.195 J.204 j.214

I.224 I.234 I.245 I.256 I.267

1 1 . , I (

I I I

I (

( (

I

I (

I

: (

:

E C

-

I.225 I.235 I.246 I.257 I.268

O-8 o-9

0.03s 0.03:

0.04( 0.041 0.04; 0,044 0.047

0.04.t 0.041 0.04E 0,045 0.047

0.05c 0.053 0.057 0.061 D.065

0.05a 0.053 0.057 D.061 0.065

D.070 0.075 0.080 3.086 3.092

0.070 0.075 0.080 3.086 3.092

3,098 3.104 1.111 I.119 I.126

3.099 I.105 I.112 I.119 I.127

I.134 I.142 1.150 I.159 PI68

I.135 I.143 I.151 I.160 I.168

I.177 ).I86 j.196 j.205 I.216

I.178 j.187 ). 197 I.206 I.217

I.226 I.236 I.247 I.258 I.269

1 1

1 1 ’ ,

I

, I

I I 1 I I I

I f

I (

I (

I

I (

:

: C

E

E a

-

I.227 I.237 I.248 I.259 I.271

-

28

Page 33: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TEMPERATURE OF AIR, “C

5

10

15

20

25

30

35

40

IS : 8897 - 1978

TABLE 2130

NOMINAL CAPACITY 30 cd

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

PRESSURE OF AIR IN mmHg

730

+o~ool

to.001

0.000

0.000

-0~001

-0~002

-0.002

-0.003

740

+0.002

+0.001

+0.001

0~000

-0~001

-0~001

-0.002

-0.002

750

+0,002

+0.002

+0.001

0.000

0.000

-0~001

-0~001

-0.002

760

+0,003

+0.002

+0.001

t_O.OOl

0~000

0.000

-0~001

-0.002

770

+0.003

$0.002

+0.002

+0.001

to.001

0~000

-0~001

-0~001

780

$0.003

+0.003

$0.002

+0.002

+0.001

0.000

0.000

-0~001

790

+0.004

$0.003

+0.003

+-0.002

+0.001

+0.001

0.000

0~000

29

Page 34: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/40

NOMINAL CAPACITY 40 cd

(Coefficient of cubical thermal expansion of glass 10 x 10-B/oC) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/40).

TEMP

W& tot

16

:I 19 20

0’0 0’1 o-2 O-3 o-4 o-5 0.6 o-7 0’8 o-9

0.051 0.051 0.051 0.051 0,052 0,052 0.052 0.052 0.052 0.052

0.052 0.052 0.052 0.052 0.052 0.052 0.053 0.053 0,053 0.053 0.053 0,053 0.053 0.054 0.054 0.054 0.054 0.054 0,054 0,055 0.055 0.055 0.055 0.055 0.056 0.056 0.056 0.056 0,057 0.057 0.057 0.057 0.058 0.058 0.058 0.058 0.059 0.059 0.059 0,060 0.060 0.060 0,061 0.061 0.061 0.062 0,062 0.062 0.063 0,063

0.063 0.064 0.064 0.064 0.065 0,065 0.066 0.066 0,066 0.067 0,067 0,068 0.068 0.068 0.069 0,069 0.070 0.070 0,071 0.071 0.072 0.072 0,073 0.073 0.074 0.074 0,074 0.075 0,075 0.076 0.077 0.077 0.078 0.078 0.079 0,079 0,080 0.080 0,081 0.081 0.082 0.082 0.083 0.084 0.084 0.085 0.085 0.086 0,087 0,087

0.088 0.088 0.089 0,090 0,090 0,091 0,092 0,092 0,093 0,093 0.094 0.095 0.095 0.096 0.097 0.097 0.098 0,099 0.099 0.100 0.101 0.102 0.102 0.103 0.104 0.104 0.105 0.106 0,107 0.107 0.108 0.109 0.110 0.110 0.111 0,112 0.113 0.113 0,114 0.115 0.116 0.116 0.117 0,118 0.119 0.120 0.120 0.121 0.122 0.123

0.124 0.125 0.125 0,126 0.127 0,128 0.129 0.130 0.131 0.131 0.132 0.133 0.134 0.135 0.136 0.137 0.138 0,138 0.139 0.140 0,141 0.142 0.143 0.144 0.145 0.146 0.147 0.148 0.149 0.149 0.156 0.151 0.152 0.153 0,154 0.155 0.156 0.157 0.158 0.159 0.160 0.161 0.162 0.163 0.164 0.165 0.166 0.167 0.168 D.169

0.170 0.171 0.172 0.173 0.174 0.175 0.176 0.177 0.178 II.179 0.181 0.182 0.183 0,184 0.185 0,186 0.187 0.188 0.189 3.190 0.191 0.192 0.194 0.195 0.196 0.197 0.198 0.199 0.200 3.201 0.202 0.204 0.205 0,206 0.207 0.208 0,209 0.210 D.212 3.213 0.214 0.215 0,216 0.217 0.219 0.220 0.221 0.222 0.223 3.225

0.226 0.227 0.228 0.229 0.231 0,232 0,233 0.234 0.236 3.237 0.238 0.239 0.240 0.242 0.243 0.244 0,245 0.247 0,248 3.249 0.251 0.252 0.253 0.254 0.256 0.257 0.258 0.259 0.261 3,262 0.263 0.265 0.266 0.267 0.269 0,270 0,271 0.273 3.274 3.275 0.277 0.278 0.279 0.281 0.282 0.283 0.285 0.286 3.287 I.289

o-290 0.291 0.293 0.294 0,296 0.297 0.304 0.305 0.307 0.308 0.310 0.311 0.318 0.319 0.321 0.322 0,324 0.325 0.332 0.334 0.335 0.337 0.338 0.340 0.347 0.349 0,350 0.352 0.353 0.355

0.298 cl.300 0.312 D.314 0.327 0.328 0.341 D.343 0.356 D.358

3.301 I.303 3,315 I.317 3,330 I.331 3.344 I.346 3.359 I.361

TEMP

AEER tot

30

Page 35: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TEMPERATURE OF AIR, “C

5

10

15

20

25

30

35

40

IS : 8897 - 1978

TABLE 2140

NOMINAL CAPACITY 40 cm3

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

PRESSURE OF AIR IN mmHg

730

+0,002

+0.001

0.000

-0~001

-0~001

-0.002

-0~003

-0.004

740

+o.ooz

+0.001

+o~ool

0.000

-0~001

-0.002

-0.002

-0~003

750

+0.003

+o~ooz

+0.001

0,001

0.000

-0~001

-0~002

-0.003

760

+0.003

+0.003

+0.002

+0.001

0.000

0.000

-0~001

-0.002

770

+0.004

+0,003

+0.002

+0.002

+o~ool

0.000

-0~001

-0~001

780

+0,005

+0.004

+0,003

i-O.002

+0.001

+o~ool

0.000

-0~001

-

~ _

-

790

+0.005

+0.004

+0.004

+0.003

+0.002

$0~001

0.000

0.000

31

Page 36: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/!M NOMINAL CAPACITY 50 cm3

(Coefficient of cubical thermal expansion of glass IO x IO-e/‘C) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/50)

TEMPE- RATURE

vJ::ER tot

5

;

t 10

:; 18

:t

z: 23 24 25

0-O

3.064

0.065 0.066 0.068 0.071 0.075

0,079 0.084 0.090 0.096 0.102

0.110 0.118

“0::;; 0.145

0.155 0.165 0.176 0.188 0.200

0.213

;I;$; 0.253 0.267

0.282 0.297 0.312 0.32: 0.34f

0.36: 0.38( 0.396 0.41( 0.434

-

.-

C

: C C (

: ( ( (

(

I I I

I I

, I

: I

1 I

I t

I 1

i I

’ I

, ’ /

,

) i

1 I

c -

0.1 0.2 0.3 0.4

I.064 3.064 I.064 I.064

I.065 0.065 3.065 I.065 PO67 3.067 3.067 I.067 j.069 3.069 3,069 I.070 I.072 D.072 3.072 I.073 j.075 0,076 0,076 3.077

I.080 0.080 D.081 3.081 j.085 0.085 0.086 3.086 j.090 0.091 0.091 3.092 j.096 0.097 0,098 0.098 I.103 0.104 0.105 0.105

I.110 0.111 0.112 0.113 I.118 0.119 0.120 0.121 I.127 0.128 0.129 0.13c I.136 0.137 0.138 0.135 I.146 0.147 0.148 0.145

3.156 0.157 0.158 0.155 3.166 0.167 0.169 0.17( 3.178 0.179 0.180 0.181 3.189 0.190 0.192 0.19: 3.201 0.203 0.204 0.20:

3.214 0.215 0.216 0.21{ 3.227 0,228 0.230 0.231 0.241 0,242 0.243 0.24: 0.254 0,256 0.257 0.251 0.269 0.270 0.272 0.271

0,284

EF c 0.33i 0.34;

0.285 0,287 0.28t 0.301 0.302 0.30< 0.31E 0.318 0.32( 0.332 0.334 0.33( 0.34: 0.351 0.35:

0.364 0.36E 0.368 0.36! 0,382 0.38: 0.38: 0.38’ 0.395 0.401 0.402 0.40. 0.41; 0.41: 0.42 1 0.42: 0.43E 0.43E 0.44c 0.44:

0’5

j.064

I.066 I.067 $070 I.073 3.077

I.081 3.087 3.093 D.099 D. 106

Il.114 0.122 0.131 0.14c 0.15c

0.16C 0.171 0.18; 0.194 0.2ot

0.215 0.23; 0,24f 0,26( 0.27:

0.29( 0.30: 0.32 0.33: 0,35‘

0.37 0.38! 0.40’ 0.421 0.44:

0.6

j.065 ( I.065

I.066 I.068 I.070 I.073 3.077

I.066 I.068 I.070 I.074 I.078

I.082 I I.082 3.087 I I.088 3.093 I 3,094 D.100 ) I 3.100 0.107 I 3.107

0.114 I D.115 0.123 ; I D. 123 0.131 I 0.132 0.141 , 0.142 0.151 , 0.152

0.161 / 0.162 0.172 , 0.173 0.18? I 0.184 0.19: i 0.196 0.20E I 0.205

0.22c 0.234 0.24; 0.26: 0.27(

0.291 0.30: 0.32: 0.33: 0.35(

0.222 0.23:

%’ 0.27:

0.291 0.3ot 0.32~ 0.341 0.35;

0.37: 0.39( 0.401 0.42’ 0.44!

0.37: 0.39: 0.41( 0.421 0.44:

-7

-

0.7 0.8

I.065

I.066 I.068 I.071 1.074 I.078

I.083 I.088 I.094 I.101 3.108

3.116

:: :f; D. 143 0.153

0.163 0.174 0.186 0.19e 0.21c

0,223 0.23f 0.25C 0.26: 0.27s

0.294 0.311 0.32( 0.34: 0.355

0.37t 0.391 0.41: 0.43( 0.44!

o-9

I.065 5

I.066 j.068 I.071 I.075 I.079

I.083 I.089 I.095 I.102 I.109

:: 13 14 15

3.117 3.125 3.134 3.144 3.154

16 17 18

:t

3.164 cl.175 D, 187 0.199 0.211

:: 23 24 25

0.224 0.238 0.252 0.26E 0.281

0.29E 0.31; 0.32E 0.344 0.361

0.37E 36 0.39t 37 0.414 38 0.43: 39 0.451 40

‘EMPE- AWRE

!JZER tot

32

Page 37: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TEMPERATURE OF AIR, “C

5

10

15

20

25

30

35

40

TABLE 2150

NOMINAL CAPACITY

IS : 8897 - 1978

50 cm3

.Uowance for temperature and pressure of air. Xdd (+) to mass or subtract (-) from it.

730 740

--

$0.002 -1-0.003

+0,001 +o.ooz

0.000 +0.001

-0~001 0.000

-0~002 -0~001

-0.003 -0.002

-0.004 -0.003

-0~004 -0.004

_

-

PRESSURE OF AIR IN mmHg

750

-1-0.004

+0.003

+0.002

+0,001

0~000

-0~001

-0~002

-0.003

760 770

PP

-j- 0,004 +0.005

+0.003 +0.004

+0x)02 +0.003

+0*001 +0.002

0.000 +0.001

-0~001 0.000

-0~002 -0~001

-0.003 -0.002

780

+0.006

to.005

+0.004

+0.003

+0.002

+o~ool

0.000

-0~001

790

-+0.007

$-0.005

+0.004

+0,003

-to.002

+0.001

0.000

-0~001

33

Page 38: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/60 NOMINAL CAPACXN 60 cm3

(Coefficient of cubical thermal expansion of glass 10 x 10-s/°C) apacity of vessel at 27°C Add to mass (grams) of pl

‘in we water at t”C to obtain ci conjunction with Table 2/61 07.

-

_

C

I : (

I ( ( (

I I

I I

I , ,

i / i

I 1

1 )

I ,

1 7

7

7

I

)

t

-

II.2

-

I.077

I.078 1.080 I.083 I.086 I.091

j.096 ). 102 1.10s ).llE Fl2E

3.131 1.14: 3.151 3.16‘ D.l7(

0.181 0.20 0.21‘ 0.221 0.24:

0.25: 0.27, 0.291 0.30 0.32,

0.34: 0.36 0.381 0.391 0,41!

0.43! 0.46( 0.48 D.50: 3.521

-

(

( ( ( I

I

I

,

,

1

1

1 1

,

1

1

I

-

TEMPE-

RATURE

GER

tot

0’0 61 0.5 0.6

I.077 j.077 LO77

I.078 j.079 I.081 j.081 I.083 I.084 I.087 I.088 3.092 I.092

I.079 j.081 J.084 I.088 I.093

D.097 3.098 I.098 D.103 3.104 I.105 0.110 D.111 I.112 0.118 0.119 3.120 0.126 0.127 3,128

0.135 0.136 0.137 0.145 0.146 0.147 0.156 0.157 0.158 0.167 0.168 0.169 0,178 0.180 0.181

0.191 0.192 0,19? 0.204 0,205 0.20( 0.217 0.219 0.22c 0.231 0.233 0.234 0.246 0.248 0.245

0.261 0.263 0.264 0,277 0.279 0.28( 0.294 0.29.5 0.29; 0.311 0.312 0.31” 0.328 0.330 0.33:

0.346 0.348 0.35( 0.364 0.366 0.36f 0.383 0.385 0.38: 0.403 0.405 0.40; 0,423 0,425 0.42;

0.443 0.445 0.44; 0.464 0.466 0.46: 0.486 0,488 0.49( 0.508 0.510 0.51: 0.530 0.532 0.534

0.7

I.078

I.079 I.081 j.084 j.089 I.093

I.099 I.105 I.112 I.120 I.129

I.138 3.148 D.159 0.170 0.182

0.194 0.208 0.221 0.236 0.251

0.26E 0.282 0,295 0.31t 0.33:

0.351 0.37( 0.385 0.40: 0.425

0.4x 0.471 0.492 0,514 0.537

0.8

1.078

I.079 1.082 1,085 1,089 b.094

I.100 ). 106 I.113 I.121 I.130

I.139 I.149 I.160 3,171 3.183

D.196 0.209 0.223 0.237 0.252

0,268 0.284 0.3oc 0.3li 0.33:

E’ 0.39; 0.411 0.431

0.451 0.47? 0.494 0.516 0.539

O-9

5 I.077

6 7 8

1:

j.078 b.080 I.082 I.086 I.090

I.095 I.101 I.107 I.115 I.123

16

:: 19 20

3,132 3.141 0.151 0.162 0.174

21

:3 24 25

0.18f 0.19E 0.21; 0.22c 0.24(

26 0.25: 27 0.271 28 0.28; 29 0.304 30 0.321

31

z: 34 35

0.335 0.35; 0.376 0.39: 0.41:

36

ii 39 40

0.435 0.456 0.477 0.499 0.521

I.077

I.078 I.080 I.082 I.086 j.090

I.095 I.101 I.108 I.116 I.124

I.133 3.142 3.152 0.163 0.175

0.18; 0.2oc 0.21? 0.225 0.24:

0.25; 0.27:

8% 0.32:

0.341 0.355 0.37E 0.39; 0.41;

0.437 0.45.E 0.479 0.501 0.523

I.077

I.078 I.080 3.083 3.087 D.091

0.097 0.103 O.llC 0.117 0.12:

0.134 0.14L 0.15‘ 0.16t 0.17:

0.18: 0.20: 0.21( 0.23( 0.241

0.26( 0.27( 0.29: 0*30! 0.32(

0.341 0.36: 0.38: 0.40 0.42

0.44 0.46: 0.48‘ 0.50: 0.521

I.078

I.079 I.082 3.083 3.089 D.094

D.100 0.107 0.114 0.122 0.131

0.14c 0.15( 0.161 0.17: 0.18’

0.19: 0,21( 0.221 0.23: 0.23

0.261 0.28: 0.30: 0.31! 0.33’

0.35! 0.37‘ 0.39: 0.41: 0.43:

0.45‘ 0.471 0.49’ 0.51! 0.54

34

Page 39: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

fs : 8897 - 1978

TABLE 2(6O

NOMINAL CAPACITY 60 cm3

~llonxxx for temperature and pressure of air. Add (-:-) to mass or subtract (-) from it.

TEMPE- PRESSURE OF AIR IN mmH~ RATUKE - OF A11r t”C 730 735 740 745 750 755 760 765 770 775 780~ 785 790

- --____ __ -~___

5 -1-‘003 +.003 -+.003 -j ,004 m.004 -(-.OOj im,005 -,-.007 ,007 _i ,007 +.008

6 -j-.002 +‘003 +.003 +,004 J-.004 +.005 +.OOs +.005 +.OOG +.()()(j -j-.007 t.007 _+.008 7 +.002 G.003 +.003 l-.003 1m.004 j-.004 -1.005 +.005 +.006 j-.006 -;-,006 _\+.007 ja.007 8 -1.002 -:-,002 -1.,003 +.003 --(-.004 +.004 -i-.004 9 10

J-.006 r ,-,006

+.005 1.,005 .) .OOG -) .OOfj t.007 ;.007 -+.002 -1.002 +.002 $.003 -J--003 +.004 -+.004 -t-.005 +.OO.? +.006 +.OO(j 1.006 +.007 -i-.001 ;-,002 +.002 +,003 +.003 +.004 mk.004 -1.,004 +.005 -1..005 i-.006 _;+.006 +.007

11 t.001 -1.002 t.002 +-'00“ t.003 -I-'003 t.004 -;+.004 -; ,005 i-.005 -!-,005 e(m.006 +_.006 12 +.OOl -i-.001 +.O@i -i-.002 -i-.003 j-,003 -i-.003 -i-.004 -i-.004 I ,005 -I_.005 _,_.'_06 f.006

:"4 +‘OOl -}-‘001 +--OF:! +‘002 -I-'002 +.003 +.003 i-.004 t.004 -:-'005 -+.005 +.005 +.006 0.000 +.001 +.001 -j-.002 .-.002 j-.003 +.003 -1_.003 +.004 +.004 -,..005 j-.005 +.006

15 0.000 +.OOl +.OOl j-.001 -1.,002 +.002 -1_.003 +.003 -+.004 -i-.004 +.004 +.005 +.OOJ

16 0’000 0’000 -t’OOl +‘OOl -i+‘OO2 +‘002 +‘003 +‘003 -i-.003 im.004 -I ‘004 +,005 4.005 17 0.000 0.000 t.001 -+.OOl i.001 t.002 t.002 +.003 t.003 ++004 m:-.o04 i.004 1.005 18 0.000 0.000 0.000 +.001 -fm.ool -i_,oo2 +.002 -;-,002 j-.003 -; ,003 -+.004 -+.004 1.005 19 -‘OOl 0’000 0.000 i-.001 +.OOl +.OOl +.002 +.002 -i ,003 ,003 -1 ,004 _I-.004 -+_.004 20 --001 0.000 0.000 0~000 i~.OOl +.OOl 1 ,002 +.ooo y-.002 ;+003 m,m.oo3 +.004 +.004

21 --001 -.OOl 0.000 0.000 -i--.001 +.001 -1.,001 +.002 +.002 +.003 ~~ ,003 4 ,003 +.004 22 --001 --001 --001 0.000 0.000 +.001 +.001 -i-.002 +.002 +.002 ,003 +.003 +.004 23 -‘002 -‘OOl -‘OOl 0’000 0’000 0’000 +.OOl +.OOl -i-.002 -i-.002 -!L,003 +.OQ3 1.003 if -.002 -,002 --001 -.002 -.OOl --001 -,OOl -.OOl 0.000 0.000 0.000 0.000 +.001 0.000 +.001 t.001 + +.001 ,001 +.002 +.002 -, ~, ,002 ,002 +.003 +.002 +.003

+.003

26 -‘002 -‘002 -‘OOl -‘OOl -‘OOl 0’000 0’000 +.OOl t.001 im.OO1 -m.002 t.002 t.003 27 -.002 -.002 -.002 --001 -.OOl 0.000 0.000 0.000 +.001 -1~ .OOl --,002 +.002 +.002 28 -.003 --002 -.002 -.OOl -.OOl -.OOl 0.000 0.000 +.001 +.OOl ,001 +.002 +.002 29 -.003 --003 -.002 --001 -.OOl 0.000 0.000 0.000 m-m.OO1 30 --003 --003’--002

--002 +.001 +.002 +.002 --002 -.002 --001 -.OOl 0.000 0.000 0.000 .001 +.OOl +.002

31 -.003 --003 -.003 --002 -.002 -.OOl -.OOl -.OOl 0.000 0.000 mi..OO1 t.001 +.001 32 --004 --003 -.003 -.002 -.002 --002 -.OOl -.OOl 0.000 0.000 0.000 -j-.001 +.001 33 --004 --003 -.003 -.003 -.002 --002 -.OOl --001 --001 0.000 0.000 +.001 +.OOl 34 -.004 -.004 -.003 -.003 --002 -,002 -so02 -.OOl -.OOl 0.000 0.000 0.000 +.001 35 --004 --004 -.003 -.003 -,003 --002 --002 -.OOl ~_.OOl --,001 0.000 0.000 +.001

36 --004 --004 -,004 -.003 -.003 -.002 --002 -.002 --,001 -.OOl __.OOl 0.000 0.000 37 -.005 -.004 --004 -.004 -.003 -.003 --002 -.002 -.002 -.OOl -.OOl 0.000 0.000 38 -,005 --005 -.004 -.004 -.003 -.003 -.003 -.002 -.002 -.OOl -.OOl _.OOl 0.000 39 -.005 --005 -.004 -.004 -.004 -.003 -.003 -.002 --,002 -.002 _.OOl _.OOl 0.000 40 --005 --005 -.005 -.004 --004 -.003 --003 -.003 -.002 -.002 __.OOl _.OOl -.OOl

35

Page 40: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

1s : 8897 - 1978

TABLE lA/7Q NOMlNAL CAPACITY 70 cm3

(Coefficient of cubical thermal expansion of glass 10 x lO-E/0C) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/70).

TEMPE- RATURE

G&R tot

5

f

t 10

2: 23

f4

26 27

z: 30

:: 33 34 35

36 37 38

z

0.0 O-1 O-2 o-3 o-4 o-5 O-6 O-7 0.8 o-9

0.090 0.090 0.090 cl.090 0.090 0.090 0.090 0,090 0,091 0.091

0.091 0.091 0.091 Lb091 0.092 0.092 0.092 0.092 0.092 0.093 0.093 0.093 0,093 3.094 0,094 0.094 0.095 0.095 0.095 0.096 0.096 0.096 0,097 0.097 0.097 0.098 0.098 0.099 0.099 0.099 0.100 0.100 0.101 0.101 0.102 0,102 0.103 0.103 0.104 0,104 0.105 0.105 0.106 D. 107 0.107 0.108 0.108 0.109 0.110 0.110

0.111 0.111 0.112 0.113 0.113 o-114 0.115 0.115 0.116 0.117 0.118 0,118 0.119 0.120 0.121 0.121 0.122 0.123 0.124 0.125 0.125 0.126 0.127 0.128 0.129 0.130 0.130 0.131 0. I 32 D.133 0.134 0.135 0.136 0.137 0.138 0.139 0.139 0.140 0.141 D. 142 0.143 0.144 0.145 D. 146 0.147 0.148 0.149 0.150 0.151 cl.153

0.154 0.155 0.156 0.157 0.158 0.159 0.160 0,161 0.162 0.164 0.165 0.166 0.167 II.168 0.169 0.170 0.172 0.173 0,174 0.175 0.176 0.178 0.179 0.180 0.181 0.183 0.184 0.185 0.187 3.188 0.189 0.190 0.192 0.193 0.194 0.196 0.197 0,198 0.200 3.201 0.202 0.204 0.205 0.207 0.208 0.209 0.211 0.212 0.214 3.215

0.217 0.218 0.220 0.221 0.222 0,224 0.225 0,227 0.228 0.230 0.231 0.233 0.234 0.236 0.238 0.239 0.241 0.242 0.244 D.245 Or247 0.249 0.250 0.252 0.253 0.255 0.257 0.258 0.260 3.262 0.263 0.265 0.267 0 268 0.270 0.272 0.273 0.275 0.277 0,278 0.280 0.282 0.284 0.285 0.287 0.289 0.291 0.292 0.294 0.296

0.298 0.299 0.301 0.303 0.305 0.307 0.309 0.310 0.312 0.314 0.316 0.318 0.320 0.321 0.323 0.325 0.327 0.329 0.331 0.333 0.335 0.337 0.339 0.341 0.343 0.344 0.346 0.348 0.350 0.352 0.354 0.356 0,358 0.360 0.362 0.364 0.366 0.368 0,370 0.372 0.374 0.376 0.379 0,381 0.383 0,385 0.387 0.389 0.391 0.393

0.395 0.397 0.399 0.401 0.404 0,406 0.408 0.410 0.412 0.414 0.416 0.419 0.421 0.423 0,425 0.427 0.430 0.432 0.434 0.436 0.438 0,441 0.443 0.445 0.447 0.450 0,452 0,454 0.456 0.559 0.461 0.463 0,465 0.468 0.470 0.472 0.475 0.477 0.479 0,482 0484 0.486 0.489 0.491 0 493 0.496 0.498 0.500 0.503 0.505

0.508 0.510 0,512 0.515 0.517 0.520 0.522 0.525 0.527 0,529 0.532 0.534 0.537 0.539 0.542 0.544 0.547 0.549 0.552 0.554 0.557 0.559 0.562 0.564 0.567 0.569 0.572 0.574 0.577 0.579 0.582 0.584 0.587 0.590 0.592 0.595 0,597 0.600 0.602 0.605 0.608 0,610 0.613 0.616 0.618 0.621 0.623 0,626 0.629 0.631

~EMPE- LATURE

NAOTFER tot

36

Page 41: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TEMPE- RATURE

OF ‘ZIR

tOc

IS : 8897 - 1978

TABLE 2170

NOMINAL CAPACITY 70 cd

A~~O\VZLIICX for temperature and pressure ofair. Add (A-) to mass or subtract (-1 from it,

PRESSURE OF AIR IS nmHg

’ 730 735 740 745 750 755 760 765 770 775 780 785 790

----__-_____~_,

t.003 t-.003 +.004 _1-,003 m+.005 m;-.006 +.006 m/+.007 +.OOj +.008 - .008 ~1m.009 -1..009

i-.003 -+.003 +.004 +.004 m'm.OO,j ~+.005 .OO(j m;m.OOC .( .OOj im.O(jj ~, ,008 +.008 +.009 1+.002 +,003 -1 ,003 -~,004 I ,004 + .005 im.005 m,.006 +.OOj .: .OOj t.008 -i-.008 t.009 +.002 mt.003 1+.003 t.004 1.004 1 ,005 +.005 :-.006 +.006 +.007 mu ,007 +.008 -1.,008 l-,002 -I-,00:! +.O03 +,003 ~ .004 +,004 m!+,00,5 m~+.00.5 1 ,006 1..OOCj +.OOj i-.007 +.008 t.002 -(m,002 +,003 -i-.003 :-,004 m1+.OO4 +~,OOL mt.00.5 t.006 -1 .006 1.007 +.007 +.008

I .OOl -: ,002 ;-.002 -! ,003 ! ,003 m: .004 m+.oo4 .O()i _; ,005 .()()ti -;- .006 +.007 {m.OOj +.OOl :~.002 -I-'002 t.003 -L.O03 -+.004 -i-.004 m'~.00.5 _t.()(),j ~1 ~006 +.OOfj +~007 -+.007 '~,OQl "001 im.002 +.002 ~.003 m'm.003 +.004 my.OO4 ) .()(I' +.00,5 .: .()O(j +.Ol)fj +-.OOj

/-,001 -i-.001 I-.002 -1.,002 -1. ,003 mlL.oo3 +.004 ,~.004 +.00:i ! ~00.5 -t.(K)6 -+.006 -t--.007 0.000 t~.OOl -(m.OOl +.002 +.002 -j .003 -1m.003 -:-.004 ;..004, t.OO.5 ~1 ,005 +.006 +.OOc,

0.000 0.000 +.001 lm.ool $.002 m/~.oo2 +.003 -' ,003 ,004 -:~ ,004 i .()05 m+.oo5 +.006 0.000 0.000 -'r,OOl +.OOl +.002 +.002 +,003 -, .003 / ,004 i-.004 4 .005 +.005 -i-.006 -.OOl 0,000 0.000 -i-.001 i-.001 1 ,002 -+.002 +.003 +.003 mt.004 +-,004 +.OQ5 +.OOj -.OOl 0~000 0.000 '.OOl m'm.OO1 -' ,002 +.002 m1+.oo3 i~.OO3 tm.004 I ,004 _i-.005 +.005 -.OOl -.OOl 0.000 0.000 +.001 _'~ ,001 ,~.002 i ,002 I ,003 -: ,003 + .004 +.004 -+.005

-.OOl -,OOlI 0.000 0.000 tm.OO1 -1 .OOl ~1 .002 -I-,002 t.003 I-,003 +.004 4 ,004 -i-.005 -.002 --,001 -.OOl 0.000 0~000 I ,001 -/ .OOl +.002 c.002 1.003 im.003 _;[email protected] +.004 __ .002 -.OOl -.OOl 0.000 0.000 +.001 {m.OO1 +.002 ~i_.OO2 +.002 -_+.003 +.003 +.004 ._ ,002 --002 -.OOl~ -.OOl 0.000 0.000 +.001 -+.001 I..002 -+.002 i.003 +.003 -1.,004 -.002 -,002 -,OOl -.OOl 0.000 0.000 -/ ,001 +.001 I.001 i~.OO:! $~.002 +.003 -i-.003

-.003 -,002 --002 -.OOI -.OOl 0~000 0.000 m,m.ool +.001 ;+.002 4.002 +.003 -I-,003 -.003 -.002 -.002 -.OOl -,OOl --,001 0.000 0.000 mLm.OO1 1.001 '..002 .b.O02 +.003 -.003 --,003 -.002 -.002 --.OOl -.OOl 0.000 0.000 i_.OOl +~ool -.002 +.002 +.003 -.on3 -.003 -.002 -.002 -.002 -.OOl -.OOl 0.000 0.000 +.001 G.001 +.I)02 +.002 -.004 -,003 -.003 --002 -.002 -.OOl -.OOl 0.000 0.000 +.001 !..OOl +.002 +.002

-.004, -.003 -.003 -.003 -.002 -.002 -.OOl -.OOl 0.000 0.000 _.OOl +.OOl -1.,002 -,004 p.004 -.003 -.003 -.002 -.002 -,OOl -.OOl 0.000 0.000 m-.OOl i-.001 +.001 -.004 --,004 -.004 -,003 -.003 -.002 --002 -.OOl -.OOl 0.000 0.000 t.001 -i-.001 -.ooi -.004 -.004 -.003 -.003 --002 --002 -.OOl -.OOl -.OOlm 0.000 0.000 +.001 -.005 p.004 -.004 --004 -.003 -.003 -.002 --,002 -.OO] -.OO] 0.000 0.000 +-,001

-.005 -,005 -.004 -.004 -.003 -.003 -.002 --002 -.002 -.OO] _-,001 0.000 0.000 -,005 -.005 --005 -.004 -.004 -.003 -.003 -.002 -.002 -.OOl -.OOl 0.000 0.000 -.006 -,005 -.005 -.004 -.004 -.003 -.003 --003 -.002 e-002 -.OOl _.OOl 0.000 -.006 -.006 -.005 -.005 -.004 -.004 -.003 -.003 e.002 p.002 -.OOl _.OOl 0.000 -.006 p.006 -.005 -.005 -.004 -.004 -.004 -.003 _.003 _.002 -.002 _.OOl _.OOl

37

Page 42: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TEMPE- RATURE

WOAER toe

5 0.096 0.096 0.096 D.096 3.097 I.097 0.097 0.097 0.097 0.097

f 8

18

0.097 0.097 0.098 0.098 De098 I.098 0.098 0.099 0.099 0.099 0.099 0.100 0.100 0.100 D.101 3.101 0.101 0,102 0.102 0,102 0.103 0.103 0.103 0.104 0.104 3.105 0.105 0.106 0.106 0.107 0.107 0.107 0.108 0.109 0.109 3.110 0.110 0.111 0.111 0.112 0.112 0.113 0.114 0.114 0.115 D.115 0.116 0.117 0.117 0.118

11 12

:“4 15

16 17

:t 20

0.119 0.119 0.120 0.121 0.121 0.122 0.123 0.124 0.124 0.125 0.126 0.127 0.128 0.128 0.129 0.130 0.131 0.132 0.133 0.133 0,134 0.135 0.136 0.137 0.138 0.139 0.140 0.141 0.142 0.143 0.143 0.144 0.145 0.146 0.147 0.148 0.149 0.150 0.151 0.153 0.154 0.155 0.156 0.157 0.158 0.159 0.160 0.161 0.162 0.163

0.165 0.166 0.167 0.168 0.169 D.170 0.172 0.173 0.174 0.175 0.176 0.178 0.179 0.180 0.181 0.183 0.184 0.185 0.186 0.188 0.189 0.190 0.192 0.193 0194 0.196 0.197 0.198 0.200 0.201 0.203 0.204 0.205 0.207 0208 0.210 0.211 0.213 0.214 0.215 0.217 0.218 0.220 0.221 O-223 0.224 0.22F 0.227 0.229 0.231

0.232 0.234 0.235 0.237 0.238 0.240 0.242 0.243 0.245 0.246 0.248 0.250 0.251 0.253 0.255 0.256 0.258 0.260 0.261 0.263 0.265 0.266 0.268 0.270 0.271 0.273 0.275 0.277 0.278 0.280 0.282 0.284 0.286 0.287 0.289 0.291 0.293 0.295 0.296 0,298 0.300 0.302 0.304 0,306 0.308 0.309 0.311 0.313 0.315 0.317

0.319 0.321 0.323 0.325 0.327 0.329 0,331 0.333 0.335 0,336 0.338 0.340 0.342 0.344 0.346 0.348 0.351 0.353 0.355 0.357 0.359 0.361 0.363 0.365 0.367 0.369 0.371 0.373 0.375 0.377 0.380 0.382 0.384 0.386 0.388 0.390 0.392 0.395 0.397 0.399 0.40 1 0.403 0.406 0.408 0.410 0.412 0.414 0.417 0.419 0,421

3:

5-i 35

0.423 0.426 0.428 0,430 0.432 0.435 0.43i 0.439 0.442 0.444 0446 0.449 0.451 0.453 0.456 0,458 0.46C 0.463 0,465 0.467 0.470 0.472 0.474 0.477 0.479 0.482 0.484 0.485 0.489 0.491 0.494 0.496 0.499 0.501 0.504 0.506 0.509 O..ill 0.514 0.516 0.519 0.521 0.524 0.526 0.529 0.531 0.534 0.53E 0.539 0.541

36

zi 39 40

0.544 0.546 0.549 0.552 0.554 0.557 0.570 0.572 0.575 0.578 0.580 0.583 0.596 0.599 0.602 0.604 0.607 0.610 0.623 0.626 0.629 0.632 0.634 0.637 0.651 0.654 0.657 0.659 0.662 0.665

;:$J: 0.612 0.64C 0.66E

0,562 0.565 0.567 0.58F 0.591 0.594 0.61: 0.618 0,621 0.642 0.645 0.648 0.671 0.674 0,676

TABLE lA/75 NOMINAL CAPACITY 75 cm3

(Coefficient of cubical thermal expansion of glass 10 x 10-8/0C) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/75).

0-O O-1 o-2 o-3 o-5 0’6 o-7 O-8

~EMPE- LAlVRE

kGER tot

38

Page 43: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 2175

NOMINAL CAPACITY 75 cd

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

TEMPE-

RATURE I

OF AIR “C

5 +.003 +.004 j-.004 -;.005 +.005 i-.006 +.007 +.007 +.008 +.008 +.009 j-.009 -t.OlO

6 7

i 10

11

:z 14 15

+.003 -1.003 j-.004 + .005 t.005 +.006 +.006 +.007 +.007 +.008 +.008 +.009 +.009 4..003 +.003 +.004 +.004 +.005 1.005 +.006 +.006 +.007 +.008 +.008 j-.009 +.009 1 ,002 +.003 +.003 +.004 +.004 +.005 +.006 +.006 +.007 1.007 +.008 +.008 +.009 T.002 +.003 j-.003 +.004 +.004 +.005 +.005 +.006 +.006 +.007 +.007 i.008 +.009 +.002 j-.002 +.003 +.003 +.004 +.004 +.005 +.006 +.006 +.007 +.007 +.008 +.008

t.001 +,002 +.003 +.003 +-.004 +.004 +.005 +.005 +.006 +.006 je.007 +.007 +.008 +.OOl +.002 +.ooz +.003 +.003 +.004 +.004 +.005 +.005 +.006 +.007 +.007 +.008 +.OOl +,OOl 1.002 +.002 +.003 +.004 +XNl4+.005 +.005 +.006 +.006 +.007 +.007 +.OOl +.OOl +.002 +.002 +.003 +.003 +.004 +.004 +.005 +.005 +.006 ;.006 +.007 0.000 j-.001 +.OOl +.002 +.002 +.003 +.003 +.004 +.005 +.005 +.006 +.006 +.007

0.000 +.OOl $.OOl +.002 +.002 +.003 +.003 +.004 +.004 +.005 h.005 j-.006 1.006 0.000 0.000 +.001 +.OOl +.002 +.002 +.003 +'003 +.004 +.004 +.005 +.006 +.006 JO01 0.000 0.000 +.001 +*002 +.002 +.003 +.003 +.004 +.004-l-.005 +.005 +.006 --001 0.000 0.000 +.001 +.001 +.002 +.002 +.003 +m3 +.004 +.004 +.005 +.005 -.OOl --001 0.000 0.000 +.001 +.001 +.002 +.003 +.003 +.004 +.004 +.005 +.005

26

zl 29 30

36 37

z: 40

--001 -.OOl 0~000 0.000 +.001 -i_.OOl j-.002 +.002 +.003 +.003 -f-.004 +.004 +.005 -.002 --001 -.OOl 0~000 0.000 $.OOl t.001 +.002 +.002 +.003 +.003 j-.004 +.005 -.002 --001 --001 0.000 0.000 -;.001 +.OOl +.002 1.002 +.003 +.003 +.004 +.004 --002 -.002 --:OOl -.OOl 0.000 0.000 +.001 +.001 +.002 +.002 +,003 +.003 +,004 -.003 --002 -.002 -,OOl 0.000 0.000 j-.001 +.OOl +.002 +.002 +.003 +.003 +.004

-.003 --002 --002 -.OOl -.OOl 0~000 0.000 +.001 +.001 t.002 -+.002 d-.003 +,003 -.003 -.003 -.002 --002 -.OOl -.OOl 0.000 0.000 +.001 +.002 +.002 +.003 +,003 -.003 -,003 -.002 -.002 -.OOl -,001 0~000 0~000 -1..OOl +.001 +,002 +.002 +,003 --004 -.003 -.003 -.002 --002 -.OOl --001 0.000 0.000 +.001 +.001 +.002 +.002 --004 --003 -.003 -*002 -.002 --001 -.OOl 0.000 0~000 +,001 $.OOl +.002 +.002

--004 --004 -.003 --003 -,002 --002 -.OOl -.OOl 0.000 0~000 +.001 +.001 +.ooz --004 -.004 -.003 -.003 --002 -.002 -.OOl -.OOl 0.000 0.000 -l-.001 +.001 +.002 --005 --004 -.004 -.003 -.003 --002 --002 -.OOl -.OOl 0.000 0.000 +.001 +,001 -.005 -.005 -.004 --004 -.003 --003 --002 -.002 -.OOl -.OOl 0.000 0.000 +,001 -.005 --005 -.004 -.004 -.003 --003 --002 -.002 -.OOl --001 0.000 0.000 +.001

-.006 -.005 -.005 --004 -.004 --003 -.003 -.002 -.002 --001 -,001 0.000 0.000 -.006 -.005 -.005 -.004 -.004 --003 -.003 -.002 --002 -.OOl -.OOl 0,000 0,000 --006 --006 -.005 -.005 -.004 --004 -.003 -.003 -.002 --002 --001 -,OOl 0.000 -.006 -.OOG -.005 -.005 -a004 -.004-,003 -.003 -.002 --002 -.002 -.OOl -,OOl -.007 -.006 -.006 -.005 -.005 -.004 -.004 -.003 -.003 --002 --002 --001 -.OOl

PRESSURE OF AIR IN mmHg

’ 730 735 740 745 750 755 760 765 770 775 780 785 790 __-__------____-_

39

Page 44: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/80 NOMINAL CAPACITY 80 cd

(Coefficient of cubical thermal expansion of glass 10 x lO-B/0C) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/80).

TEMPE- RATURE

W%R tot

5 I.103 I.103 I.103 0.103 0.103 0,103 3.103

6

I

1:

I.104 I.104 I.104 I.106 3.106 1.107 3.110 3.110 3,110 D.114 3115 3.115 0.120 0.120 3.121

X% 0.111 0.116 0.122

0.105 0.105 D. 105 3.105 0.107 0.108 0.108 3.108 0.111 0.112 0,112 3.113 0.116 0.117 0.117 3.118 0.122 0.123 0.124 3.124

11 12 13 14 15

0.127 0.127 D.128 0.129 0.130 0.130 0.131 0.132 0.134 0.135 D.136 0.137 0.138 0.139 0.140 D. 140 0.143 cl. 144 D, 145 0.146 0.147 0.148 0.149 0.150 0.153 II.154 D.155 0.156 0.157 0.158 0.159 0.160 0.164 0.165 D.166 0.167 0.168 0.170 0.171 0.172

16 17 18

::

0.176 0.177 0.178 0.179 0.180 0.182 0.183 0.184 0.188 0.189 0.191 0.192 0.193 0.195 0.196 O-198 0.202 0.203 0.205 0.206 0.207 0.209 0.210 0.212 0.216 0.218 0.219 0.221 0.222 0.224 0.225 0.227 0.231 0.233 0.235 0.236 0.238 0.239 0.241 0.243

21 22

;: 25

0.248 0.249 0.251 0.253 0.254 0.256 0.258 0.25s 0.264 0.266 0.268 0.270 0.271 0.273 0.275 0.277 0.282 O-284 0.286 0.288 0.290 0.291 0.293 0.29: 0.301 0.303 0.305 0,307 0.308 0.310 0.312 0.314 0.320 0.322 0.324 0.326 0,328 0.330 0.332 0.334

Zf 28 29 30

0.340 0.342 0.344 0.346 0.348 0.351 0.353 0,355 0.361 0.363 0.365 0.367 0.370 0.372 0.374 0.376 0.383 0.385 0.387 0.389 0.391 0.394 0.396 0.39P 0.405 0.407 0.409 0.412 0.414 0.416 0.419 0.42 1 0.428 0.430 0.433 0.435 0,437 0.440 0.442 0444

31 0.452 0.454 0.456 0.459 0.461 0.464 0.466 32 0.476 0.478 0.481 0.483 0.486 0.488 0.491 33 0.501 0,504 0.506 0.509 0.511 0.514 0.516 34 0.527 0.529 0.532 0.535 0.537 0.540 0.542 35 0.553 0.556 0.558 0.561 0.564 0.567 0.569

36 0.580 0.583 0.586 0.588 0.591 0,594 0.597 37 0.608 0.611 D.613 0.616 0.619 0.622 0.625 38 D.636 3.639 3.642 0.645 0.648 0.650 0.653 39 0.665 3.668 3.671 0.674 0.677 0.680 0.683 40 D.694 3.697 I.700 0.703 0.706 0.709 0.712

-

E:f

KP 0.57;

0.599 0.628 0.656 0.686 0.715

O-8 0.9

0.104

0.106 0.106 0,109 0.109 0.113 0.114 0,119 0.119 0.125 0.126

0,133 0.134 0.141 0.142 0.151 0.152 0,162 0.163 0.173 0.174

0.186 0.187 0.199 0,200 0,213 0.215 0.228 0.230 0.244 0.246

0.261 0.263 0.279 0,280 0.297 0.299 0.316 0.318 0.336 0.338

0.357 0.359 0.378 0.380 0.400 0.403 0.423 0.426 0.447 0.449

0.471 0.474 0.496 0.498 0.522 0.524 0.548 0.550 0.575 0.577

0.602 0.605 0.630 0.633 0.659 0.662 0.689 0.691 0,719 0.722

40

Page 45: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 2ja0

NOMINAL CAPACITY a0 Cm3

Allo~vance for temperature and pressure ofair. Add (+) to mass or subtract (-) from it.

TEXPE- PRESSURE OF ,4rn IN mmHg RATLJTKE OF‘41R

’ ’ "C 730 735 740 745 750 755 760 765 770 775 780 785 790

p--____ -__ ---___-

5 +.003 -1 .004 .005 pi +.O(Jj Im ,006 +.OOF ~ '007 im.008 +.008 +.009 ~m.009 ,010 m;-010

6 +.003 i-.004 +.004 L.OO.5 m! ,OO,? +.006 +.()07 tm.007 +.008 _+.008 +.009 ,010 A-.OlO 7 a

-i-.003 im.003 +,004 -t-.005 -+,005 -b.OOfj +.OO(j +.007 +.OOT :_.008 +.009 :_.OOg _!_.OlO t.002 i-.003 -l-.004 :-.004 +.005 -{+.005 i-.006 +.007 +.007 .+.008 _~.008 A~.009 t.009

1: i-.002 -; ,003 +.003 +.004 / .004 +-.005 +.OOfj +.006 -;_.007 +.()07 t.008 m+.OO$l ;_.009 ~I-'002 _.002 ,003 ~) i .004 -i~'OO, 1 ~I 1. 005 +.OO-, A.006 t.006 -;+.007 +.008 +.008 mi ,009

:: -!,-~002 +002 : ,003 m' ,003 -+.004 -1 ,004 +.005 -I-,001 +.002 _j_.OO2 -I--OO3 _+.004 _+.004 _+.00,5

-+.006 +.006 m/+.007 _1_.007 ,008 +.008 +.005 -;-,006 $-,006 _+.007 +.008 -t-.008

13

::

+.001 1-,001 }-.002 ~i.003 +.003 t.004 .+.004 -I-.OOj +.CJO~ _+.OO(i + ,007 T ,007 -r.008 +.001 .i~~OOl i-.002 i-.002 I .003 +.003 +-,004 -k.OO.j +.005 +.006 '~.0Ofj ~ ,007 i-.007 0.000 -:+.001 _+.001 \-.Oo'l +.003 _+.003 +.004 i .004 .'L.OO,? -+.ooTt -f-.006 +~007 +.007

:f 0.000 -,~.OOl +-.OOl +.002 -j .002 -:~.003 +.003 -;.004 +.005 +.OO.i +.OOfj _1~.0Ofj ;.OOi

ia O'OOO 0.000 +.OOl j-.001 -+.002 +.003 +-,003 -+.004 _I-.004 _+.00,5 +.OO,' -! .OO(j -]-~()O(j

:o"

-,OOl 0.000 ;m.OOl +.OOi +.002 j-.002 -j-.003 +.003 +.004 +.004 j-.()05 -,m.006 +.006 -'OOl 0.000 0.000 +.OOl m+.OOl +.002 +.002 +.003 t.004 +_.004 +.005 4 .005~+.006 -.OOl -,OOl 0.000 0~000 ,-.OOl +.002 j-.002 +.003 +.003 + ,004 _1_.004 -,_.OO:, i-.005

2: -.002 --002 -.OOl -,OOl 0.000 -.OOl

0.000 0.000 j-.001 0~000 i.001 t.001 j-.002 +.002 +.003 t-.003 ,003 +.004 -:-,005 -I-,002 +.002

23 j-.003 $ _1_.004

~+~00.5 ,004 -; -i-.005

2254

-'O"2 -'OOZ -'OOl 0'000 0'000 +.OOl -t_.OOl j-.002 -i+.OO2 -i-.003 _+.003 +.004 +.005 -'Oo2 --'002 -'OOl -'OOl 0'000 0'000 -I-'001 -+'OOl +.002 ~:+,003 _I~.003 m/ .004 j.004 -.003 -.002 -.002 ---001 -,OOl 0.000 +.001 t.001 +.002 j-.002 t.003 '~.003 _+.004

26 -.003 --002 --002 -.OOl -.OOl 0.000 0.000 -1..OOl _+.002 L.002 -003 +.004 27 -.003

_, ,001 -.003 --002 -.002 -.OOl --001 0.000 +.001 +.001 +.002

28 -.004 j-.002 $003 +.003

-.003 -.003 -.002 -.OOl -.OOl 0.000 0.000

3": -.004

L.001 -1.,001 ~+.002 ~/--002 +.003 --003 -.003 --002 --002 --001 -.OOl 0.000 0.000

-,004 .;_.001 IL.002 !L.(lO2 _+.003

-.004 -.003 -.003 -.002 -.OOl -.OOl 0.000 0.000 _+.001 _; ,001 -/ ,002 .:.002

:: -.004 --005 -.004 -.004-.004 --003 -.003 -.003 --002 -.003 -.002 --002 -.OOl 0.000 -.002

-.OOl -.OOl 0.000

0.000 0.000 _;..001 i-.001 +.002 +.001 -j-.002

33 -,005 +_.00]

-.005 -.004 -.003 -,003 ---002 -.002 -.OOl -.OOl 0.000 0.000 ~; ,001 q.001 34 -.005 --005 -.004 -.004 --003 -.003 --002 -.002 _~.OOl -.OOl 0.000 0.000 i-.001 35 -.006 -.005 -.00.5 -.004 -,004 -.003 -.002 -.002 _.OOl -.OOl 0.000 0.000 -;.001

36 -,006 --00s -.oo5 --004 -.004 -.003 --003 -.002 F-002 -.Ool --001 0.000 0.000 37 -,006 --006 -.005 -.005 -,004 -.004 --003 -.003 _.002 -.()02 -.OOl 0.000 0.000 38 -.007 -,006 -.006 -.005 -.004 --004 -.003 -.003 _.002 -.002 _.OOl -.OOl 0.000 39 -.007 -.006 --006 --005 -.005 --004 -.004 -.003 -.003 w-002 _.OO' -.OOl -.OOl 40 -,007 -,007 -.006 -.006 -.005 --005 -.004 -.003 -.003 -.002 -.002 -.OO] -.OOl

41

Page 46: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/90

NOMINAL CAPACITY 90 cm3

(Coefficient of cubical thermal expansion of glass 10 ;< lo-6/“C) Add to mass (grams) of pure water at t°C to obtain capacitv of vessel at 27°C

(in conjunction with Table 2/90).

0.0 O-1 O-2 o-3 o-4 o-5 O-6 o-7

0.116 0.116 0.116 O.llC, 0.116 0,116 0.116

0.117 0.117 0.117 0.117 0.118 0.118 0.118 0,119 0.120 0.120 0.12a 0.121 0.121 0.122 0.123 0.124 0.124 0,125 0.125 0.126 0.126 0.128 0.129 0.130 0.130 0.131 0.131 0.132 0.135 0.136 0.136 0.137 0.138 0.138 0.139

0.142 0.143 0.144 0.145 0.146 0.147 0.148 0.151 0 152 0.153 0.154 0.155 0.156 0.157 0.161 0.162 0.163 0.164 0.165 0.167 0.168 0.172 0.173 0.175 0.176 0.177 0.178 0.179 0.184 0,186 0.187 0.188 0.189 0.191 0.192

0.197 0.199 0.200 0.202 0.203 0.204 0.206 0,212 0.213 0.215 0.216 0.218 0.219 0.221 0.227 0.228 0.230 0,232 0.233 0.235 0.237 0 243 0.245 0.247 0,248 0.250 0,252 0.253 0.260 0.262 0.264 0.266 0.267 0.269 0.271

0.278 0.280 0.282 0.284 0,286 0,288 0.290 0.298 0.300 0.301 0.303 0.305 0,307 0,309 0.318 0.320 0.322 0.324 0.326 0.328 0.330 0.338 0.341 0.343 0.345 0.347 0.349 0.351 0.360 0.362 0,365 0.367 0.369 0.371 0,374

0.383 0.385 0.387 0,390 0.392 0.394 0,397 0.406 0.409 0.411 0.413 0.416 0.418 0.421 3.430 0.433 0.435 0,438 0.440 0.443 0.445 3.456 0,458 0.461 0.463 0.466 0.468 0.47 1 3.481 0.484 0.487 0.489 0.492 0.495 0.497

3.508 0.511 0.513 0.516 0.519 0,522 0.524 1,535 0.538 0.541 0,544 0.547 0.549 0.552 3.564 0.567 0.569 0.572 0.575 0.578 0.581 3.593 0.596 0.598 0.601 0.604 0.607 0.610 3.622 0.625 0.628 0.631 0.634 0.637 0.640

I.653 0.656 0.659 0,662 0.665 0.668 0.671 1.684 0.687 0.690 0.693 0.696 0.700 0,703 3.716 0.719 0.722 0,725 0.729 0.732 0.735 3.748 0.751 0.755 0.758 0.761 0.765 0.768 3.781 0.785 0.788 0.791 0.795 0.798 0.802

0.118 0.122 0.127 0.133 0.140

0.148 0.158 0.169 0.181 0.193

0.207 0.222 0.238 0.2.55 0.273

0.292 0.311 0.332 0.354 0.376

0.399 0.423 0.448 0.474 0.500

0,527 0,555 0.584 0.613 0.643

0,674 0.706 0.738 0.771 0.805

0.8

-

__

0.9

0.117

0.119 0.119 0,122 0,123 0.127 0.128 0.133 0.134 0,141 0,142

0.149 0.159 0.170 0.182 0.195

0.150 0.160 0,171 0.183 0.196

0,209 0.224 0.240 0.257 0.27.5

0.210 0.225 0.241 0.259 0.277

0.294 0.313 0 334 0,356 0.378

0.296 0.315 0.336 0.358 0.380

0.401 0.426 0 450 0.476 0,503

0.404 0,428 0.4.53 9.479 0.505

0.530 0.558 0.587 D.616 0,617

0,533 Il.561 0.590 0.619 D.650

0,677 0.709 0.742 0.775 0.808

3.681 0,712 0,745 0.778 D.812

TEMPE- RATURE

GER t”C

42

Page 47: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 2190

NOMINAL CAPACITY 90 cm3

Allowance for temperature and pressure of air. Add (+) .to mass or subtract (-) from it.

TEMP OF AIR

“C

;; 23 24 25

26

36 37

zi 40

PRESSURE OF AIR IN mmHg

730 735 740 745 750 755 760 765 770 775 780 785 790

-7------ ----_____

+.004 j-*004 -+.005 +.OO(i e.006 +.OOi $-.008 +.008 $-,009 +-.OlO j-.010 +.Oll +.012

+.003 +.004 +-,005 +,005 +*006 +.007 +.007 +.008 +.009 i-.009 1.010 -I-.011 +.OlI -I-,003 +.004+.004 +.005 +,006 +.006 +.007 +.008 +.008 ;.009 i.010 +.OlO +.Oll +.003 +.003 +.004 +,005 +.005 +.006 +.007 +.007 +.008 +.009 t.009 -+,OlO +.Oll +.002 +,003 +.004 +.004 +.005 i-.006 -i-.006 +.007 +.008 -i-.008 +.009 +.OlO +.OlO +.002 +.003 +.003 +.004 +.005 +.005 j-.006 t.007 t.007 +.008 i.009 -j-.009 +.OlO

+.002 j-.002 +.003 +.004 +*004 +.005 +.006 t.006 +.007 j-.008 +.008 j-.009 +.009 +.OOl +.002 +.003 +.003 +*004 +.005 +.005 +.006 +.007 +.007 +.008 -j-.008 +.009 +.001 +.002 +.002 +.003 +a004 +.004 +.005 +.006 +.006 +.007 +.007 j-.008 +.009 +.OOI +.OOl t.002 t.003 +.003 +.004 +.005 +.005 t.006 +.006 +..007-t.008 +.008 0.000 +.001 +.002 +.002 +.003 +,004 +.004 -+.005 +.005 +.006 +.007 -i-.007 +.008

0.000 +.001 +.001 +.002 +.003 ;.003 +.004 +.004 1.005 +.006 c.006 1.007 +.008 0.000 0.000 +.OOl +.002 +.002 +.003 +.003 +.004 +.005 +.005 +.006 +.007 +.007 -.OOl 0.000 +.OOl +.OOl +.002 +.002 +.003 +.004 +.004 +.005 +.006 jm.006 +.007 -a001 0.000 0.000 +.OOl +.OOl +.002 j-.003 +.003 +.004 +.005 +.005 _[_.006 +.007 -.OOl --001 0.000 +.OOl +.001 +.002 +.002 +*003 +.004 +.004 +.005 -i-.006 +.006

--002 -.OOl 0.000 0.000 t.001 t.001 t.002 +.003 +.003 _1-.004 +.005 +.005,+_.006 -.002 --001 --001 0.000 0.000 +.OOl +.002 +.002 +.003 +.004 +.004.+.005 +.005 -.002 -.002 -.OOl -.OOl 0.000 +.OOl +.001 +.002 +.003 +.003 +.004_+.004 +.005 -.003 -.002 A.001 -.OOl 0.000 0.000 +.001 +.002 +.002 +.003 +.003 A.004 +.005 -.003 --002 --002 --001 -.OOl 0.000 +.001 +.001 +.002 +.003-k.003 +_.004 +.004

-.003 -.003 --002 --002 -.OOl 0.000 0.000 +.001 +.002 .+.002 +.003 -f-.003 +.004 --004 -.003 --002 -.002 --001 -.OOl 0.000 +.001 +.001 +.002 j-.002 +.003 +.004 --004 -.003 -.003 --002 --002 -.OOl 0.000 0.000 +.001 +001 +.002 j-.003 +.003 --004 -.004 -.003 -.003 --002 -.OOl -.OOl 0.000 0.000 +.001 +.002 j-.002 +.003 --005 -.004 -.003 -.003 --002 --002 --001 0.000 0.000 +.001 +.001 +.002 +.003

--005 --004 -.004 -.003 -.003 --002 -.OOl -.OOl 0.000 0.000 i-.001 +.002 +.002 --005 -.005 -.004 -.004 -.003 --002 --002 -.OOl LOO1 0.000+.001 -f-.001 +.002 --006 -.005 --005 -.004 -.003 -.003 -.002 -.002 --001 0.000 0.000 j-.001 +,002 -.006 --005 -.005 -.004 -.004 -.003 -.002 -.002 A-001 --001 0.000 +.OOl +.OOl -.006 -.006 -.005 -.005 --004 -.003 -.003 --002 --002 --001 0.000 0.000 +.OOl

-.007 -.006 -.006 --005 -.004 -.004 -.003 -.003 --002 -.OOl -.OOl 0.000 0.000 -.007 --006 --006 -.005 -.005 --004 -.003 -.003 --002 --002 -.OOl -.OOl 0.000 -.007 -.007 --006 -.006 -.005 -.004 -.004 -.003 --003 -.002 --001 --001 0.000 --008,~-007 --007 -.006 -.005 -.005 -.004 -.004 --003 --002 -.002 -.OOl _.OOl -.008 --007 -.007 -.006 -.006 -.005 -.005 -.004 --003 -.003 --002 --002 -.OOl

43

Page 48: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/lOO NOMINAL CAPACITY 100 cm3

(Coeficient of cubical thermal expansion of glass 10 x 1 O--6/%) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/100). -

4_

I

i

i

1

- -

:- E

R

-.

/

/

I

I

I

I

(

(

I

I

(

:

(

:

-

-

O-0

-.

3 0.12: 0.121

0.13( 0.13: 0.13: 0.14: 0,15(

0.131 0.13: 0.13: 0.14: 0.15:

0.151 0.16E 0.17: 0.191 0.20:

0.155 0.16’ 0,18( 0.19: 0.2ot

0.211 I 0.221 0.23: i 0.23; 0.25: , 0.254 0.27( I 0.27; 0.28: I 0.291

0.30: 0.331 0.352 0.376 0.400

0.311 0.332 0.355 0.37E 0.403

Z: 3.478 I.506 I.535

3.428 3.454 3.481 I.509 I.538

I.564 I.595 I.626 I.658 I.691

I.568 I.598 I.629 I.662 I.695

j.725 I.760 j.795 I.831 I.868

I.729 j.763 ). 799 1.835 I.872

0.2 0’6 0’7

-

I.125

1.13: 1.13f I.141 ).14E ).15f

1.16: ).17f 1.1% I.201 j.21:

j.230 I.245 I.265 j.283 I.303

I.324 I.346 I.369 I.393 1.418

1.443 I.470 1,498 1.526 ,556

.586 ,617 .649 ,681 ,715

,749 ,784 ,820 .857 ,894

O-8

0.12<

0.13: 0.13( 0.141 0.14E 0,15(

0.166 0.175 0.185 0.202 0.216

0.232 0,249 D.266 0.285 0.305

3.326 1.348 I.371 3.395 I.420

I.446 I.473 I.500 I.529 I.558

I.589 I.620 I.652 j.685 I.718

1,753 I.788 I.824 b.861 I.898

o-9

--

0.12! 3 1 0.12!

0.131 0.13: 0.131 0. 14z 0.15

D.13( 0.131 3.131 3.14: 3.15:

0.16( 1 ( I.161 0.1x 1 ( I.171 0,181 I ( 1.18: 0.191 c ( 1.19; 0,20[ I ( 1,201

0.22;

~:~~F 0.274 0.29:

! ( I.224 ) ( k24C i ( 1.25; 1 ( ).27t I ( 1.29:

0.314 0.33: 0.357 0.381 0.405

k31E j.337 j.360 I.383 I.408

3.430 3.457 3.484 I.512 I.541

I.433 I.459 I.487 1.515 1.544

I.571 I.601 I.633 I.665 I.698

1.574 1.604 ,636 .668 ,701

I.732

I::: J.839 I.876

.735 ,770 ,806 ,842 ,879

--

1 (

! ( i (

( i ( j (

0.12:

0.13 0.132 0.13: 0.14: 0.151

0.16: 0.17; 0.18s 0.19; 0.21(

0.22c 0.24; 0.255 0.27& 0.295

0.318 0,339 0.362 0.386 D.410

3.436 3.462 1.489 I.518 I.547

I.577 I.607 I.639 I.672 I.705

I.739 j.774 j.809 I.846 J.883

0.121

0.13 0.13i 0.14( 0.14( 0.15‘

0.16: 0,171 0.18: 0.19E 0.21;

0.227 0.244 0.261 0.28C 0.295

0.320 0.342 0.364 0.388 3,413

3.438 3.465 I.492 I.520 I550

I.580 I.611 ), 642 I.675 I.708

I.742 j.777 j.813 I.850 I.887

0.12s

0.131 0.13: 0.14( 0.14; 0.15:

0.16~ 0.174 0.186 0.195 0.21:

0.22s 0.245 0.263 0.281 0.301

0.322 0.344 II.367 D.390 3.415

I.441 3.467 I.495 I.523 I.553

I.583 I.614 I.645 I.678 I.712

I.746 I.781 j.817 I.853 j.891

).13(

1.13; S13f 1.14: I.145 1.15;

1.167 1.17s kl9C I.203 j.218

I.234 I.250 I.268 I.287 I.307

1.328 1.351 1,374 1,398 1,423

I.449 1.476 I.503 ,532 ,561

‘592 ,623 .655 ,688 ,722

,756 ,792 ,828 ,864 ,902

44

Page 49: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE Z/100

NOMINAL CAPACITY 100 cm3

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

TEMP OF a4IR "C

13

:J

16 17

:“9 20

:i 23 24 25

26 27 28

3:

31

3332 34 35

36

z 39 40

PRESSURE OF AIRIN mmHg

730 735 740 745 750 755 760 765 770 775 780 785 790

--____-______

+.004 +.005 +.006 +.006 +.007 t.008 +.009 t.009 +.OlO j-.011 t.012 +.OlZ j-.013

+.004+.005 t.005 +.006 +,007 +.008 +,008 +.009 +.OlO +.OlO +.Oll j-.012 +.013 +.003 +,004 +.005 +.006 +.006 +.007 t.008 t.009 j-.009 t.010 +.011 +.Oll +.012 +.003 +.004 +.005 +.005 +.006 +.007 +.007 +.008 +.009 +.OlO +.OlO j-.011 +.012 C.003 +.003 +.004 +.005 +.006 +.006 +*007 +,008 +.008 +.009 +.OlO j-.011 +.Oll +.002 +.003 +.004+.004 +.005 +.006 +.007 +.007 +.008 t.009 +.OlO 1.010 +.Oll

+.002 +.003 +.003 +.004 +.005 +.005 +.006 +.007 +.008 +.008 +.009 +.OlO +.Oll +.002 +.002 +.003 t.004 +.004 +.005 +.006 +.007 +.007 +.008 j-.009 +.009 j-.010 +.OOl +.002 +.003 +.003 +.004 +.005 +.005 +.006 +.007 +.008 +.008 +.009 +.OlO +.OOl -PO01 +.002 +.003 +.004 +.004 +.005 +a006 +.006 +.007 +.008 +.009 +.009 0.000 +.OOl +.002 +.002 +.003 +.004 +.005 +.005 +.006 +.007 +.007 +.008 +.009

0.000 +.OOl +.OOl +.002 +.003 +.004 +.004 +.005 +*006 +.006 +.007 +.008 +.008 0.000 0.000 +.OOl +.002 +.002 +*003 +*004 +.005 j-.005 +.006 +.007 +.007 +.008 -*OOl 0.000 +.OOl +.OOl +.002 +*003 +*003 +*004 +*005 +.006 +.006 +.007 +.008 -.OOl 0.000 0.000 +.OOl +.002 +.002 +.003 +.004 d-.004 +.005 +.006 +.007 +.007 --002 --001 0.000 +.OOl +.OOl +.002 +.003 +.003 +.004 +.005 1.,005 -i-.006 +.007

--002 -.OOl -.OOl 0.000 +.OOl +*002 +.002 t.003 +.004 +.004 +.005 +.006 +.006 -.002 --002 --001 0.000 +.OOl +.OOl +*002 +.003 +.003 t.004 +.005 -!m.005 +.006 -.003 -.002 --001 -.OOl 0.000 +.OOl +.OOl +.002 +.003 +.004 1.004 +.005 +.006 -.003 -.002 i-002 -.OOl 0.000 0.000 +.001 +.002 +.002 +.003 +.004 +.005 +.005 -,003 -.003 -.002 --001 --001 0.000 +.001 +.001 +.002 +.003 j-.003 t.004 t.005

-.004 --003 -.002 7.002 -.OOl 0.000' 0000 +.001 +.002 +.002 +.003 +.004 +.004 -.004 -.003 -.003 --002 --001 -.OOl 0.000 +.001 +.001 +.002 +.003 +.003 +.004 -.004 -.004 -.003 -.002 --002 --001 0.000 0.000 +.001 +.002 +.002 j-.003 f.004 -,005 --004 -.004 -.003 --002 --001 -.OOl 0.000 +.001 +.001 +.002 i-.003 +,003 --005 -,005 --004 -,003 -.003 --002 --001 --001 0.000 $.OOl +.002 +.002 +.003

-.006 --005 --004 --004 -.003 -.002 --002 --001 0.000 0.000 +.OOl +.002 +.002 -.006-.005 -.005 -.004-,003 -.003 --002 -.oOl -.ool 0.000 +.OOl +.OOl +.002 -.006 -.006 --005 --004 --004 -.003 --002 -.OOZ -,001 0.000 0.000 +.OOl t.002 -.007 --006 -.005 -.005 --004 -.003 -.003 --002 -.OOl --001 0.000 +.Ool +.OOl -.007 -.006 -.006 -.005 --004 --004 --003 --002 -.002 -.OOl 0.000 0.000 j-.001

-.007 -.007 -.006 --005 --005 --004 --003 -.003 -.002 -.002 -.OOl 0.000 0.000 -.008 -.007 -.007 -.006 -.005 -.005 --004 --003 --003 -.002 --001 -.OOl 0.000 -,008 -.008 -.007 -,006 -.006 -.005 -.004 --004 -,003 --002 -,002 --001 0.000 -.009 -.008 --007 --007 -.006 --005 -.005 -.004 -.003 -.003 --002 -.OOl -.OOl -.009 --008 -.008 -.007 -.006 -.006 -.005 --004 -.004 -.003 -.002 -.002 --001

45

Page 50: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/200 NOMINAL CAPACITY 200 cm8

(Coefficient of cubical thermal expansion of glass 10 x 10-s/OC) Add to mass (grams) of pure water at 1°C to obtain capacity of vessel at 27°C

(in conjunction with Table Z/ZOO).

- - - -

0.26 0.26 0.26 0.X 0.26 0.26 0.26 0.26 0.26 0.26

0.26 0.26 0.2G 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.31 0.31 0.31 0.31 0.31 0.31

0.32 0.32 0.32 0.32 0.32 0.33 0.33 0.33 0.33 0.33 0.34 0.34 0.34 O-34 0.34 0.35 0.35 0.35 0.35 0.36 0.36 0.36 0.36 0.37 0.37 0.37 0.37 0.37 0.38 0.38 0.38 0.39 0.39 0.39 0.39 0.40 0.40 0.40 0.40 0.41 0.41 0.41 0.42 0.42 0.42 0.42 0.43 0.43 0.43 0.44

0.44 0.44 0.44 0,45 0.45 0.45 0.46 0.46 0.46 0.47 0.47 0.47 0.48 0.48 0.48 0.49 0.49 0.49 0.50 0.50 0.50 0.51 0.51 0.51 0.52 0.52 0.53 0.53 0.53 0.54 0.54 0.54 0.55 0.55 0.56 0.56 0.56 0.57 0.57 0.57 0.58 0.58 0.59 0.59 0.59 0.60 0.60 0.61 0.61 0.61

0.62 0.62 0.63 0.63 0.64 0.64 0.64 0.65 0.65 0.66 0.66 0.67 0.67 0.67 0.68 0.68 0.69 0.69 0.70 0.70 0.71 0.71 0.71 0.72 0.72 0.73 0.73 0.74 0.74 0.75 0.75 0.76 0.76 0.77 0.77 0.78 0.78 0.79 0.79 0.80 0.80 0.81 0.81 0.82 O-82 0.83 0.83 0.84 0.84 0.85

0.85 0.86 0 86 0.87 0.90 0.91 0.91 0.92 0.96 0.96 0.97 0.97 1.01 1.02 1.02 I.03 1.07 1.08 1.08 1.09

0.87 0.88 0.88 0.89 0.89 0.90 0.92 0.93 0.93 0.94 0.95 D.95 0,98 0.98 0.99 1.00 1.00 1.01 1.04 1.04 1.05 1.05 1.06 1.06 1.09 1.10 1.11 1.11 1.12 1.12

1.13 1.14 1.14 1.15 1.19 1.20 1.20 1.21 1.25 1.26 1.27 1.27 1.32 1.32 1.33 1.34 1.38 1.39 l-40 1.40

1.15 1.16 1.17 1.17 1.21 1.22 1.23 1.23 I.28 1.28 1.29 1.30 1.34 1.33 1.36 1.36 1.41 1.42 1.42 1.43

1.18 I.18 1.24 1.25 1.30 1.31 1.37 1.38 1.44 1.44

1.45 1.46 1.46 1.47 1.48 1.52 1.53 1.53 1.54 1,5.? 1.59 1.60 1.60 1.61 1.62 1.66 1.67 1.68 1.68 1.69 1.74 1.74 1.75 1.76 1.77

1.48 1.49 1.50 1.51 I.51 1.55 1.56 1.57 1.58 1.58 1.63 1.63 1.64 I.65 L.66 1.70 1.71 1.71 1.72 L.73 1.77 1.78 1.79 1.80 I.80

-

-

TEMPE- RATURE

W&t t”C

46

Page 51: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TEMPERATURE OF AIR

“C

5

t

f 10

:: 13 14 15

16 17

:: 20

z: 23 24 25

26 27

:: 30

31

E 34 35

36

ii 39 40

T -

7

--

TABLE 2/200

NOMINAL CAPACITY 200 cm3

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

PRESSURE OF AIR IN mmHg

30 735 740 745 750 755 760 765

I

770 775 780

_-y---P --_-

-.Ol +.01 +-01 +.01 +.01 +.02 +.02 +.02 +.02 +.02 +.02

-.Ol +.01 +.Ol i_‘Ol +.01 +.02 +.02 +.02 +.02 +*02 1’02 -.Ol +.01 +.01 +.Ol +.01 +.Ol +.02 +.02 +.02 +.02 +.02 -.Ol +.01 +*01 +.Ol +.Ol +.01 +.Ol +.02 i-.02 +.02 +.02 -.Ol +.01 +.01 +.Ol +.01 +.01 +.01 +.02 +.02 +.02 +.02 3.00 +.01 +.01 +.Ol +.01 +.Ol +.01 +.Ol +.02 +.02 +.02

3.00 +.01 +.01 +.Ol +.01 +.Ol +.Ol +.Ol +.02 +.02 +.02 D.00 0.00 +*01 +.Ol +.Ol +.Ol +.Ol +.Ol +.Ol +a02 +.02 0.00 0.00 +.Ol +.Ol +.Ol +.Ol +.Ol +.Ol +.Ol +.02 +.02 0.00 0.00 0.00 +.Ol +,01 +.Ol +*01 +.01 +.Ol +.01 +.02 D.00 0.00 0.00 0.00 +.Ol +.Ol +a01 +.Ol +.Ol +.Ol +.Ol

0.00 0.00 0.00 0.00 +.01 +.Ol +.01 +.Ol +.01 +.Ol +.01 0.00 0.00 0.00 0.00 0.00 +.Ol +.01 +.Ol +.Ol +.01 1.01 0.00 0.00 0.00 0.00 0.00 -1.01 +.01 i.01 +.01 +.01 +.Ol 0.00. 0.00 0.00 0.00 0.00 0.00 +.01 +.01 +.Ol +.Ol +.Ol 0.00 0.00 0.00 0.00 0.00 0.00 +.01 +,Ol +.Ol +.Ol t.01

0.00 0.00 0.00 0.00 0.00 0.00 0.00 +.01 +.01 +.01 +.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 +.01 -i_.Ol +*01 +.01 -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 0.00 +.01 +.Ol +.01 -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 +.01 1.01 -.Ol --01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 +.01 +.01

-.Ol -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 +.01 -.Ol -.Ol -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 0.00 +.01 -.Ol --01 -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 0.00 O.O( -.Ol -.Ol --01 -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 O.O( -.Ol -.Ol -.Ol -.Ol --01 0.00 0.00 0.00 0.00 0.00 O.O(

-.Ol --01 -.Ol -.Ol --01 0.00 0.00 0.00 0.00 0.00 O.O( -.Ol -.Ol --01 -.O] -.Ol -.Ol --01 -.Ol --01 --01 -.Ol -.Ol -.Ol -.Ol --01 -.Ol

--01 --01 -.Ol -.Ol -.02 --01 --01 --01 -.02 -.02 -.Ol -.Ol -.02 -.02 --01 --01 -.02 -.02 -.02 -.O]

-.Ol -.Ol --01 --01

--01 -*Ol -.Ol --01 -.Ol

-.Ol 0.00 0.00 0.00 0.00 O.O( -.Ol 0.00 0.00 0.00 0.00 O.O( -.Ol --01 0.00 0.00 0.00 O.O( -.Ol -.Ol 0.00 0.00 0.00 O.O(

-.Ol -.Ol -.Ol 0.00 0.00 O.O( -.Ol -.Ol --01 --01 0.00 O.O( -.Ol -.Ol -.Ol -.Ol 0.00 0.01 --01 --01 --01 -.Ol -.Ol 0.01 -.Ol --01 -.Ol --01 --01 0.01

785 790

--

j-.02 i-.03

t.02 +.03 t.02 +.02 t.02 +.02 t.02 +.02 t.02 t.02

t.02 +.02 t.02 +.02 t.02 +.02 t.02 +.02 t.02 +.02

t.02 +.02 t.01 +G? $-a01 +.02 +.01 t.01 t.01 -+,01

t.01 ;-.Ol t.01 +.01 t.01 -+.01 +.01 +.01 +.01 +.Ol

+.01 +.01 +.01 jF.01 +.01 +.01 +.01 +.01 0.00 +.01

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

47

Page 52: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/250 NOMINAL CAPACITY 250 cd

(Coefficient of cubical thermal expansion of glass 10 x 10-6/“C~ Add tb mass (grams) of pure water at t”C to obtain ca

(in conjunction with Table 2/25l pas city ofvessel it 27°C

TEMPE- RATURE

WZR tot

-i

0-O 0.1 o-2 o-3 o-4 o-5 O-6

-

--

o-7 O-8 0.9

5 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32

0.32 0.32 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.35 0.35 0.35 0.35 0.35 0.35 0.36 0.36 0.36 0.36 0.36 0.36 0.37 0.37 0.37 0.37 0.37 0.37 0.38 0.38 0.38 0.38 0.38 0.39 0.39 0.39 0.39

1’:

:i 15

0.40 0.40 0.40 0.40 0.40 0.41 0.41 0.41 0.41 0.42 0.42 0.42 0.43 0.43 0.43 0.43 0.44 0.44 0.44 0.44 0.45 0.45 0.45 0.46 0.46 0.46 0.47 0.47 0.47 0.48 0.48 0.48 0.48 0.49 0.49 0.49 0.50 0.50 0.50 0.51 0.51 0.52 0.52 0.52 0.53 0.53 0.53 0.54 0.54 0.54

16 17 18

:t

0.55 0.55 0.56 0.56 0.56 0.57 0.57 0.58 0.58 0.58 0.59 0.59 0.60 0.60 0.60 0.61 0.61 0.62 0.62 0.63 0.63 0.63 0.64 0.64 0.65 0.65 0.66 0.66 0.67 0.67 0.68 0.68 0.68 0.69 0.69 0.70 0.70 0.71 0.71 0.72 0.72 0.73 0.73 0.74 0.74 0.75 0.75 0.76 0.76 0.77

0.77 0.78 0.78 0.79 0.79 0.80 0.81 0.81 0.82 0.82 0.83 0.83 0.84 0.84 0.85 0.85 0.86 0.87 0.87 0.88 0.88 0.89 0.89 0 90 0.90 0.91 0.92 0.92 0.93 0.93 0.94 0.95 0.95 0.96 0.96 0.97 0.98 0.98 0.99 0.99 1.00 1.01 1.01 1.02 1.03 I.03 1.04. 1.04 1.05 1.06

1.06 1.07 1.08 1.08 1.09 I.10 1.10 I.11 1.12 1.12 1.13 1.13 1.14 1.15 1.15 I,16 1.17 1.18 1.18 1.19 1.20 1.20 1.21 1.22 1.22 1.23 1.24 1.24 1.25 1.26 1.27 1.27 1.28 1.29 1.29 1.30 1.31 1.32 1.32 1.33 1.34 1.34 1.35 1.36 1.37 1.37 1.38 1.39 1.40 1.40

31 32

E 35

1.41 1.42 I.43 I.43 1.44 I.45 I.46 1.4G 1.47 1.48 1.49 1.50 1.50 I.51 1.52 1.53 1.53 I.54 1.55 1.56 1.57 1.57 1.58 1.59 1.60 1.61 1.61 1.62 1.63 1.64 1.65 1.65 1.66 1.67 1.68 1.69 1.70 1.70 1.71 1.72 1.73 1.74 1.75 1.75 1.76 1.77 1.78 1.79 1.80 1.80

1.81 1.82 1.83 1.84 1.85 1.86 1.86 1.90 1.91 1.92 1.93 1.93 1.94 1.95 I.99 2.00 2.01 2.01 2.02 2.03 2.04 2.08 2.09 2.10 2.11 2.11 2.12 2.13 2.17 2.18 2.19 2.20 2.21 2.22 2.23

1.87 1.88 1.89 1.96 1.97 1.98 2.05 2.06 2.07 2.14 2.15 2.16 2.24 2.25 2.25 l -

JJ.

48

Page 53: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 21250

NOMINAL CAPACITY 250 cm3

Allowance for temperature and pressure of air. Add (-t_) to mass or subtract (-j from it.

TEMPERATURE PRESSURE OF AIR IN mmHg OF AIR

“C

5

::

:: 15

16 17 18

:t

;; 28 29 30

730 735 740 745 750 755 760 765 770 775 780 785 790

__------_--_-__

-+.01 +.01 +.01 +,02 +.02 +.02 +.02 +.02 +.03 +.03 +.03 +.03 +.03

+.01 +.01 +,01 +.02 +.02 +.02 +.02 +.02 +.02 +.03 i-.03 +.03 +,03 +.01 +.01 +.01 +.01 +.02 +.02 +.02 +.02 +.02 +.03 +.03 +.03 +.03 +.01 +.01 +.01 +.01 +.01 +.02 +.02 +,02 +.02 +,02 +.03 +.03 +.03 +.01 +.01 +.01 +.01 +.01 t.02 +.02 +.02 -l-.02 +.02 +.02 +.03 +,03 +.01 +.01 t.01 +.01 +.01 t.01 +,02 +.02 +.02 +,02 +.02 +,03 +.03

0.00 +.01 +.01 +.01 +.01 +.Ol +.02 +.02 +.02 -+.02 +.02 1.02 +,03 0.00 +.01 +.01 +.01 +.01 +.01 +.Ol +.02 -/-.02 +.02 +-.02 +.02 +.03 0.00 0.00 +,01 +.01 +.01 +.Ol +.Ol +,02 +.02 +,02 +.02 +.02 +.02 0.00 0.00 +.01 +.01 +.01 +.01 +.Ol +.01 +.02 i.02 +.02 1.02 +.02 0.00 0.00 0.00 +,01 +.01 +.01 +.01 t.01 +-.o.z +.02 +.02 +.02 +,02

0.00 0.00 0.00 +.01 +.01 +.Ol +.Ol +.01 +,01 1.02 +.02 +*02 +.02 0.00 0.00 0.00 0.00 +.01 +.01 +.01 +.01 +.01 +.01 +.02 $-GO2 +.02 0.00 0.00 0.00 0.00 +.01 +.01.+.01 +.01 +.01 1.01 +.02 +.02 +,02 0.00 0.00 0.00 0.00 0.00 i-.01 +.Ol +.01 +,01 d-.01 +.01 +.02 +.02 0.00 0.00 0.00 0.00 0.00 0.00 +.01 +,01 +.01 +.01 +.01 +.02 +.02

b 0.00 0.00 0.00 0.00 o,oo 0.00 +.Ol +.01 +.01 t.01 +.01 j-.01 +.02

-.Ol 0.00 0.00 0.00 0.00 0.00 0.00 +.Ol t.01 t_.Ol +,01 +.01 +.02 -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 +.Ol i-.01 +.01 +.01 +.01 +.01 -.Ol -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 t.01 +.01 -+,01 +.01 t.01 -.Ol -.Ol -.Ol 0.00 0.00 0.00 0.00 0.00 +.01 +.01 +.01 +.01 i-,01

-.Ol -.Ol -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 +.01 +.01 +.01 t.01 -.Ol -.Ol --01 -.Ol 0.00 0.00 0.00 0.00 0.00 +.01 +.01 +.01 +.01 -.Ol -.Ol -.Ol --01 0.00 0.00 0.00 0.00 0.00 0.00 +.01 +.01 +.01 -.Ol -.Ol -.Ol -.Ol --01 0.00 0.00 0.00 0.00 0.00 0.00 +.01 +.01 -.Ol -.Ol --01 -.Ol --01 0.00 0.00 0.00 0.00 0.00 0.00 +.01 +.01

-.Ol -.Ol --01 --01 -.Ol -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 +.01 -.Ol -.Ol -.Ol --01 --01 --01 0.00 0.00 0.00 0.00 0.00 0.00 +.01 -.02 -.Ol --01 -.Ol --01 --01 -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 --02 -.02 --01 -.Ol --01 -.Ol -.Ol -.Ol 0.00 0.00 0.00 0.00 0.00 --02 --02 -.Ol --01 -.Ol -.Ol -.Ol --01 0.00 0.00 0.00 0.00 0.00

-.02 --02 -.02 --01 --01 --01 --01 --01 -.Ol 0.00 0.00 0.00 0.00 -.02 --02 -.02 -.Ol --01 --01 --01 -.Ol -.Ol 0.00 0.00 0.00 0.00 --02 -.02 -.02 -.02 -.Ol -.Ol -.Ol --01 --01 -.Ol 0.00 0.00 0.00 --02 --02 -.02 -.02 --01 --01 -.Ol -.Ol --01 -.Ol -.Ol 0.00 0.00 --02 --02 -.02 -.02 -.02 --01 --01 -.Ol --01 --01 --01 0.00 0.00

49

Page 54: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE IA/500 NOMINAL CAPACITY 500 cm3

(Coefficient of cubical thermal expansion of glass 10 x 10-s/OC) Add to mass (grams) of pure water at t”C: to obtain capacity of vessel at 27°C

(in conjunction with Table Z/500).

TEMPE- RATURE

w&R L"C

5

t 8

*“o

11

:z

:5

16 17 18

::

;: 23 24 25

26 27

E 30

31 32

:: 35

Lb-0 0.1

- -

0.64 0.64

0.65 0.66 0.68 0.71 0.75

0.65 0.67

;:;; 0.75

0.79 0.80 0.84 0.85 0.90 0.90 0.96 0.96 1.02 1,03

1.10 1.18 1.26 1.35 1.45

I.10 1.18 1.27 1.36 1.46

1.55 I.56 1.65 1.66 1.7c 1.78 1.88 1.89 2.00 2.01

2.14

;:;I 2.54 2.6:

2.82 2.84 2.97 2.9s 3.1: 3.1: 3.25 3.31 3.4t 3.47

3.6? 3.64 3.8C 3.82 3.9E 3.9: 4.16 4.17 4.34 4.3E

9.2 P3

0.64 0.64

0.65 0.65 0.67 0.67 0.69 0.69 0.72 0.72 0.76 0.76

0.80 0.81 0.85 0.86 0.91 0.91 0.97 0.98 1.04 I.05

1.11 1.12 1.19 1.20 1.28 1.29 1.37 1.38 I.47 1.48

1.57 1.58 1.67 1.69 1.79 1.80 1.90 1.92 2.03 2.04

2.15 2.16 2.28 2.30 2.42 2.43 2.5E 2.57 2.7C 2.72

2.85 2.87 3.01 3.02 3,lE 3.1.E 3.32 3.34 3.45 3.51

3.6E 3.6P 3.82 3.85 4,Ol 4.03 4.1s 4.21 4.33 4.4c

3.4 Ll.5 I.6 P7 0.8 0’9

-

D.64

0.65 0.67 0.70 0.73 0.77

-

3.64 I.65 I.65 0.65 0.65

0.66 cl.66 3.66 0.66 0.66 0.67 0.68 3.68 0.68 0.68 0.70 0.70 D.70 0.71 0.71 0.73 0.73 D.74 0.74 0.75 0.77 0.77 0.78 0.78 0.79

0.81 0.81 0.82 0.82 0.83 0.83 0.86 0.87 0.87 0.88 0.88 0.89 0.92 0.93 0.93 0.94 0.94 0.95 0.98 0.99 1.00 1.00 1.01 1.02 1.05 1.06 1.07 1.07 1.08 1.09

1.13 1.14 1.14 1.15 1.16 1.17 1.21 1.22 1.23 1.23 1.24 1.25 1.30 1.31 1.31 1.32 1.33 1.34 1.39 1.40 1.41 1.42 1.43 1.44 1.49 1.50 1.51 I.52 1.53 1.54

1.59 1.60 1.61 1.62 1.63 1.64 1.70 1.71 1.72 1.73 1.74 1.75 1.81 1.82 1.83 1.84 1.86 1.87 1.93 1.94 1.95 1.96 1.98 1.99 2.05 2.06 2.08 2.09 2.10 2.11

2.18 2.31 2.45 2.59 2.73

2.19

;:;; 2.60 2.75

2.20 2.22 2.23 2.24 2.34 2.35 2.36 2.3E 2.47 2.49 2.50 2.52 2.62 2.63 2.65 2.6E 2.76 2.78 2.79 2.81

2.88 2.90 2.91 2.93 2.94 3.04 3.05 3.07 3.08 3.10 3.20 3.21 3.23 3.24 3.26 3.36 3.37 3.39 3.41 3.42 3.52 3.54 3.56 3.57 3.59

;::I

3.2; 3.44 3.61

3.69 3.71 3.73 3.75 3.76 3.7{ 3.87 3.89 3.90 3.92 3.94 3.9( 4.05 4.07 4.08 4.10 4.12 4.1’ 4:23 4.25 4.27 4.28 4.30 4.3: 4.42 4.43 4.45 4.47 4.49 4.51

-

rEMPE- ATURE

GER tot

5

:: 13

:f

16

:z

::

21 22

E 25

26

:I 29 30

;: 33 34 35

36 37

:t 40

50

Page 55: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 2/500

NOMINAL CAPACITY 500 cm3

Allowance for temperature and pressure of air. Add ($1 to mass or subtract (-) from it.

TEMPERATURE PRESSURE OF AIR IN mmHg OF AIR

“C 730 735 740 745 750 755 760 765 770 775 780 785 790

-- ---------__

5 +.02 +.02 +,03 +.03 +.04 +.04 +.04 +.05 +.05 +.05 +.06 $.06 +.07

6 +.02 +.02 +.03 +.03 +.03 +.04 +.04 +.04 +.05 t.05 +.06 f.06 +.06

z +.02 +.02 +.02 +.03 +.03 1.04 +*04 +.04 +.05 +.05 +.05 +.06 +.06 +.02 +.02 +.02 +.03 +.03 +.03 +.04 +.04 +.04 +.05 +.05 +.06 +.06

1: +.Ol +.02 +.02 +.02 +.03 +.03 +*04 +.04 +.04 +*05 +.05 +05 +.06 +.01 +.02 +.02 +.02 +.03 +.03 +*03 -+.04 +.04 +.04 +.05 +.05 +.05

:: +.01 +.01 +.02 +.02 +.02 +.03 +*03 +.03 +.04 +.04 q-.05 +.05 +.05 +.01 +.01 t.01 -PO2 +.02 +.03 +.03 +.03 +.04 +.04 +.04 +.05 +.05

13 +.01 +.01 +.01 +.02 +.02 +.02 +.03 +.03 +.03 +.04 +.04 $.04 +.05 14 0.00 +.01 +.01 +.01 +.02 +.02 +.03 +.03 +*03 +.04 +.04 j-.04 +.05 15 0.00 +.01 +.01 +.01 +a02 +*02 +.02 +.03 +.03 +.03 +.04 +.04 +.04

16 0.00 0.00 $.Ol +.01 +.Ol +.02 +*02 j-.02 +.03 +.03 +.04 +.04 +.04

:; 0.00 0.00 +.01 +.01 +.Ol +.02 +.02 +.02 +*03 +.03 +.03 +04 +.04 0.00 0.00 0.00 +.01 +.01 +.01 +.02 j-.02 +.02 +.03 +.03 +.03 +,04

:t --01 0.00 0.00 0.00 +.Ol +*01 +.02 +.02 +.02 +.03 +.03 +.03 +.04 -.Ol 0.00 0.00 0.00 +.Ol +.01 +.01 +.02 +.02 +,oz +,03 $.03 +.03

:: -.Ol --01 -,Ol -.Ol 0.00 0.00 0.00 0.00 0.00 0.00 +.01 +.01 +.01 +.01 +.Ol +.01 +.02 +.02 +.oz +.02 +.03 +.02 +.03 +.03 +.03 +.03 23 --01 -.Ol JOI 0.00 WOO 0.00 +-01 +.01 +.01 +.02 +.02 +.02 +.03 24 -.02 -.Ol --01 0.00 0.00 0.00 +.01 +.Ol +.01 +.02 +.02 +.02 +.03 25 -.02 -.Ol -.Ol -.Ol 0.00 0.00 0.00 +.Ol +.01 +.01 +.02 +.02 +.02

26 -.02 -Jo2 -.Ol --01 --01 o,oo 0.00 +.Ol +.01 +.01 -.02 +.02 +.02

f Z -.02 -.02 --02 -.02 --01 -.02 --01 -.Ol -.Ol -.01 --01 0.00 0.00 0.00 0.00 0.00 +.01 0.00 +.01 +.01 +.01 +.01 +.02 +.01 +.02 +.02

:: -.02 --03 --02 -.02 -.02 -.02 -.02 --01 -.Ol --01 -.Ol --01 --01 0.00 0.00 0.00 0.00 0.00 +.01 0.00 +.01 +.01 +.Ol +.01 +.02 +.01

31 --03 -,02 -.02 -.02 -.Ol --01 -.Ol 0.00 0.00 0.00 +.01 +.01 +.01

z -.03 -.03 -,03 -.03 -.02 -.03 -.02 -.02 -.02 -.02 --01 -.02 -*Ol --01 --01 -.Ol -.Ol 0.00 0.00 0.00 0.00 0.00 +.01 0.00 +.01 +.01 34 --03 -.03 --03 -.02 --02 -.02 --01 --01 -.Ol 0.00 0.00 0.00 +.01 35 -,04 -.03 -.03 --03 --02 -.02 -*02 -.Ol -.Ol --01 0.00 0.00 0.00

36 -.04 -.03 -.03 --03 --02 -.02 --02 -.Ol -.Ol --01 0.00 0.00 0.00

z: -*04 -.04 --04 -.04 --03 -.03 -.03 --03 -.03 -.03 -.02 -.02 --02 -.02 -.02 -.02 -.Ol -.Ol --01 -.Ol --01 -.Ol 0.00 0.00 0.00 0.00 39 -.04 -.04 --04 --03 -.03 --03 -.02 -.02 --02 JO1 -.Ol -.Ol 0.00 40 -.04 -.04 --04 -.03 -.03 -.03 --03 -.02 -.02 -.02 -.Ol -.Ol -.Ol

51

Page 56: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/l 000 NOMINAL CAPACITY 1000 cd

(Coefficient of cubical thermal expansion of glass 10 x IO-B/%) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/l 000).

TEMPE RATUR

WZL t”C

- - - - -

1.2E 1.29 1.29 1.29 1.29 1.29 1.29 1.29

1.3c 1.3c 1.3c 1.30 1.31 1.31 1.31 1.32 1.32 1.32 1.32 1.32 1.33 1.34 1.34 1.35 1.35 1.36 1.36 1.36 1.35 1.35 1.38 1.39 1.39 140 1.40 1.41 1.41 1.42 1.42 1.49 1.44 1.45 1.45 1.46 1.47 1.48 1.48 1.49 1.5c 1.51 1.51 1.52 1.53 1.54 1.55 1.56 1.56 1.57

1.58 1.59 1.60 1.61 1.62 1.63 1.64 1.65 1.66 1.67 1.68 1.69 I.70 1.71 1.72 1.73 1.74 I.76 1.77 1.78 1.75 1.8C 1.81 1.83 1.84 1.85 1.86 1.87 1.89 1.90 1.91 1.93 1.94 1.95 1.97 1.98 1.99 2.01 2.02 2.03 2.05 2.06 2.08 2.09 2.10 2.12 2.13 2.15 2.16 2.18

2.19 2.21 2.22 2.24 2.26 2.27 2.29 2.30 2.32 2.34 2.35 2.37 2.39 2.40 2.42 2.44 2.45 2.47 2.49 2.50 2.52 2.54 2.56 2.57 2.59 2.61 2.63 2.65 2.66 2.68 2.7a 2.72 2.74 2.76 2.78 2.80 2.81 2.83 2.85 2.87 2.89 2.91 2.93 2.95 2.97 2.99 3.01 3.03 3.05 3.07

3.09 3.11 3.14 3.16 3.18 3.20 3.22 3.24 3.26 3.28 3.31 3.33 3.35 3.37 3.39 3.42 3.44 3.46 3.48 3.51 3.53 3.55 3.57 3.60 3.62 3.64 3.67 3.69 3.71 3.74 3.76 3.78 3.81 3.83 3.86 3.88 3.90 3.93 3.95 3.98 4.00 4.03 4.05 4.08 4.10 4.13 4.15 4.18 4.20 4.23

4.25 4.28 4.30 4.33 4.36 4.38 4.41 4.43 4.46 4.49 4.51 4.54 4.57 4.59 4.62 4.65 4.67 4.70 4.73 4.76 4.78 4.81 4.84 4.87 4.89 4.92 4.95 4.98 5.00 5.03 5.06 5.09 5.12 5.15 5.18 5.20 5.23 5.26 5.29 5.32 5.35 5.38 5.41 5.44 5.47 5.50 5.53 5.56 5.58 5.61

5.64 5.68 5.71 5.74 5.77 5.80 5.83 5.86 5.89 5.92 5.95 5.98 6.01 6.04 6.07 6.11 6.14 6.17 6.20 6.23 6.26 6.29 6.33 6.36 6.39 6.42 6.45 6.49 6.52 6.55 6.58 6.62 6.65 6.68 6.72 ii.75 6.78 6.81 6.85 6.88 6.91 6.95 6.98 7.01 7.05 7.08 7.12 7.15 7.18 7.22

7.25 7.29 7.32 7.35 7.39 7.42 7.46 7.60 7.63 7.67 7.70 7.74 7.77 7.81 7.95 7.99 5.02 3.06 3.09 3.13 8.17 8.31 3.35 3.39 3.42 3.46 3.50 8.53 B. 68 3.72 3.76 3.79 3.83 3.87 8.91

7.49 7.84

;:;y 8.94

7.53 7.56 7.88 7.92 8.24 8.28 8.61 8.64 6.98 9.02

TIEMPE-

IATURE

W::ER tot

52

Page 57: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 2/1000

NOMINAL CAPACITY 1000 cd

Allowance for temperature and pressure of air. Add (+) to mass 01‘ subtract (-) from it.

TEMPERATURE PRESSURE OF AIR IN mmHg OF AIR "C

---_--_____-- III III 730 735 740 745 750 755 760 765 770 775 780 785 790

5 +.04 +,05 +.06 +,06 +.07 +.08 +.09 +.Og +,10 +.I] +.I2 +.I2 +.f3

! +.04 +.05 +.05 +,06 +.07 +.08 +.08 +.09 +.I0 _t. 10 +.11’+.12 -j-.13 +.03 +.04 +.05 j-.06 +.06 +.07 +.08 +.09 +.09 1.10 +.I1 +.I1 +.I2

t +.03 +.041+.05 $-.05 +,06’+.07 +.07 +.08 +.09 +.lO 1.10 +.ll +.I2 +,03 +.03 1.04 +.05 +.06 t.06 +.07 +.08 1.08 +.09 +.lO +.ll +.ll

10 +.02+.03-l-.04 +.04 -1.05 +.06 +.07 +.07 1.08 +.09 +.lO +.I0 j-.11

:: +.02 +.03 +.03 +.04 +.05 1.05 t.06 +.07 +.08 +.08 +.09 +.lO +.I1 +.02 f.02 +.03 +,04 +.04 +.05 +.06 +.07 +.07 +.08 +.09 $.09 +.lO

13 +.Ol +.02 -+.03 +.03 +.04 +.05 +.05 +.06 +.07 f.08 +.08 +.09 +.lO . 14 +.Ol +,Ol +.02 +.03 +,04 +.04 +.05 +.06 +.06 +.07 1.08 j-.09 +.09 15 0.00 +.Ol +.02 +,02 +.03 +.04 +.05 t.05 1.06 +.07 +.07 +.08 +.09

16 0.00 +.Ol i.01 +.02 +.03 +.04 +.04 +.05 +.06 $.06 +.07 +.08 +.08

:z 0.00 0.00 +.Ol +,02 +.02 +.03 -j-.04 +.05 +.05 +.06 +.07 +.07 +.08

--01 0.00 +.Ol i-,01 +.02 1.03 +.03 +.04 +.05 +.06 +.06 +.07 +.08 :; --01 0.00 0.00 +,Ol +.02 +.02 1.03 +.04 +.04 +.05 + 06 +.07 +.07

-.02 -.Ol 0.00 +.Ol t.01 +.02 +.03 t.03 +.04 +.05 +.05 +.06 +.07

g -.02 -.02 --03 --01 -.02 -.02 --01 --01 --01 --01 0.00 0.00 c.01 +.Ol 0.00 +.Ol +.02 +,Ol +.02 +.02 +.03 +.03 +.03 j-.04 +.04 +.04 +.05 +.05 +.06 +.05 +.05 1.06 +.06 +.06 +.Ol +.02 +.03 +.04 +.04

E -.03 -.0.3 -.02 -.03 -.02 --02 -.Ol -.Ol --01 0.00 0.00 0.00 +.01 +.02 +.02 +.03 1.04 +.04 +.05 +.05 +.05 +.01 +.01 +.02 +.03 +.03

Zf --04 --04 -.03 --03 ---02 --03 -.02 -.02 -.Ol --01 --01 0.00 0.00 0.00 +.01 +.02 +.02 +.03 +.03 +.04 +.04 +.04 +.01 +.01 +.02 +.03

St --05 --04 --04 --04 --04 -.03 -.02 --03 -.02 -.02 -.Ol -.OI -.Ol 0.00 0.00 0.00 +.01 +.02 +.02 1.03 +.03 +.03 +.04 +.01 +.Ol +.02

30 --05 --05 --04 -.03 -.03 -.02 --01 -.Ol 0.00 +.01 +.02 +.02 +.03

31 -.06 -.05 --04 --04 -.03 -.02 -.02 -.Ol 0.00 0.00 +.Ol +.02 +.02

iz --06 -.06 -.06 --05 -.05 --05 --04 --04 --03 --04 --03 --03 -.02 -.02 -.02 -.01 e-01 --01 0.00 0.00 +.Ol 0.00 +.Ol +.OI +.02 t.02 34 -.07 -.06 --05 --05 --04 -.03 --03 -.02 -.Ol -.01 0.00 +.Ol +.Ol 35 --07 --06 --06 --05 --04 --04 -.03 -.02 --02 --01 0.00 0.00 +.Ol

if -.07 --08 -.07 -.07 --06 -.07 -.05 -.06 --05 --05 --04 -.05 -.03 -.04--03 -.03 -.02 _.03 --02 m.02 -.01 v.01 _.Ol 0.00 0.00 0.00 ii --08 --09 --08 --08 --07 v-07 -.06 -.07 --06 -.06 --05 w.05 --04-.04--03 w.05 w-04 -.03 -.02 _.03 -.02 _.02 --01 _.Ol --01 0.00

40 -.09 --08 --08 --07 -.06 --06 d-05 e-04 B-04 _.03 w.02 _.02 ---01

53

Page 58: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TEMPE. RATURI

WZP t”C

TABLE lA/1500 NOMINAL CAPACITY 1500 cmS

(Coefficient of cubical thermal expansion of glass 10 x lO--B/uC) Add to mass (grams) ofpure water at t”C to obtain capacity ofvessel at 27%

(in conjunction with Table 2/ 1 500).

0-O

-

1.9: 1.93

1.9E 1.95

22:;; 2.25

1.9: 2.oc 2.06 2.15 2.2E

2.35 2.39 2.52 2.54 2.69 2.70 2.87 2.89 3.07 3.09

Z:Z 3.78 4.05 4.34

3.31 3.55 3.81 4.08 4.37

4.64 4.67 4.96 4.99 5.29 5.33 5.64 5.68 6.00 6.04

6.38 6.42 6.77 6.81 7.17 7.22 7.59 7.63 a.02 a.07

a.47 a.51 a.92 a.97 9.39 9.44 9.88 9.93 0.37 10.42

0.88 IO.93 1.40 11.45 1.93 Il.98 2.47 12.52 3.02 13.08

-

1.93 1.93 1.93 1.93 1.94 1.94 1.94 1.94

::;; 2.07 2.16 2.27

1.96 1.96 1.97 1.97 1.97 1.98 1.98 2.01 2.01 2.02 2.03 2.03 2.04 2.05 2.08 2.09 2.09 2.10 2.11 2.12 2.13 2.17 2. la 2-19 2.20 2.21 2.22 2.24 2.28 2.30 2.31 2.32 2.33 2.35 2.36

2.40 2.55 2.72 2.91 3.11

2.42 2.57

;:;; 3.14

2.43 2.44 2.46 2.47 2.49 2.50 2.58 2.60 2.62 2.63 2.65 2.67 2.76 2.78 2.79 2.81 2.83 2.85 2.95 2.97 2.99 3.01 3.03 3.05 3.16 3.18 3.20 3.22 3.25 3.27

3.34 3.36 3.38 3.41 3.43 3.46 3.48 3.50 3.58 3.60 3.63 3.65 3.68 3.70 3.73 3.76 3.83 3.86 3.89 3.92 3.94 3.97 4.00 4.02 4.11 4.14 4.17 4.19 4.22 4.25 4.28 4.31 4.40 4.43 4.46 4.49 4.52 4.55 4.58 4.61

4.70 4.74 4.77 4.80 4.83 4.86 4.89 4.93 5.02 5.06 5.09 5.12 5,16 5.19 5.22 5.26 5.36 5.39 5.43 5.46 5.50 5.53 5.57 5.60 5.71 5.75 5.78 5.82 5.86 5.89 5.93 5.97 6.08 6.11 6.15 6-19 6.23 6.26 6.30 6.34

6.46 6.49 6.53 6.57 6.61 6.65 6.69 6.73 6.85 6.89 6.93 6.97 7.01 7.05 7.09 7.13 7,26 7.30 7.34 7.38 7.42 7.46 7.51 7.55 7.68 7.72 7.76 7.81 7.85 7.89 7.94 7.98 8.11 a.15 a.20 8.24 8.29 8.33 8.38 a.42

8.56 8.60 8.65 8.69 8.74 8.79 8.83 8.88 9.02 9.06 9 11 9.16 9.20 9.25 9.30 9.35 9.49 9.54 9.59 9.63 9.68 9.73 9.78 9.83 9.97 IO.02 IO.07 IO.12 10.17 IO.22 10.27 10.32 0.47 IO.52 IO.57 10.62 10.67 IO.72 !0.78 IO.83

0.98 Il.03 Il.08 II.14 Il.19 II.24 ‘1.29 11.34 1.50 11.55 !1.61 .1.66 .I,71 .1.77 1.82 1l.a7 2.03 12.09 12.14 !2.20 12.25 2.30 2.36 ‘2.41 2.58 12.63 L2.69 b2.74 2.80 2.85 2.91 i2.97 3.13 13.19 !3.25 3.30 3.36 3.42 3.47 3.53

54

Page 59: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 2/l 500

NOMINAL CAPACITY I 500 cd

Allowance for temperature and pressure of air. Add (+) to mass or subtract (-) from it.

TEMPERATURE PRESSURE OF AIR IN mmHg OF AIR

“C

5 t.06 +.07 +.09 +.I0 +.ll +.12 +.13 +.I4 1.15 +.16 +.17 +.I9 +.20

;

t 10

+06 +.07 +.08 +.09 +.lO +.ll +.12 +.13 $-.I5 +.15 +.I7 +.I8 +.lg +.05 +.06 +.07 +.08 +.lO +.ll +.12 +.13 +.14 +.15 +.I6 +.17 +.18 +.05 +,06 +.07 +.08 +.09 +.lO +.ll +.12 +.13 +.14 +.16 +.17 +.18 +.04 +.05 +.06 +,07 +,08 +.09 +.ll +.I2 j-.13 +.I4 +.I5 +.I6 +.17 +.03 +05 +.06 +.07 +.08 +.09 +.I0 +.ll +.12 +.13 +.I4 +.15 +.16

::

:: 15

+.03 +.04 +.05 +,06 +.07 +.08 +.09 +.lO $-.I1 +.13 +.14 +.I5 +.16 +02 +.03 +.04 +.06 +.07 +.08 +.09 +.I0 +.I1 +.I2 +.13 +.I4 +.I5 +.02 +.03 +.04 +.05 +.06 +.07 +.08 +.09 +.lO +.ll +.12 +.13 +.15 +.Ol +.02 +.03 +.04 +.05 +.06 +.08 t.09 +,I0 +-.I1 $-.I2 +.13 +.14 +*Ol +.02 +.03 +.04 +.05 t.06 f.07 +.08 j-.09 +.I0 +.ll +.12 +.13

16 17

:t 20

0.00 +.Ol +.02 +.03 +a04 f.05 +.06 +.07 +.08 +.lO +.ll +.I2 +.13 --01 0.00 +.02 +.03 +.04 +.05 +,06 t.07 +.08 1.09 +.I0 +.ll +.12 --01 0.00 +.Ol +.02 +,03 +.04 +.05 +.06 +.07 +.08 +.09 +.lO +.ll -.02 --01 0.00 +.Ol +.02 f.04 t.05 +.06 +.07 +.08 +.09 +.lO +.ll -.02 -.Ol 0.00 +.Ol +.02 +.03 +.04 +.05 +.06 +.07 +.08 +.09 +.10

f : 23 24 25

26 27 28

:o”

--03 --02 -.Ol 0.00 i_.Ol +.02 +.03 +.04 +.05 +.07 +.08 +.09 +.10 -*03 -.02 -.Ol 0.00 +.Ol +.02 +.03 +.04 +.05 +.06 +.07 +.08 +.09 --04 -.03 -.02 --01 0.00 +.Ol +.02 +.03 +.04 +.05 +.06 +.07 +.08 --05 -.03 --02 --01 0.00 +.Ol +.02 +.03 t.04 +.05 +.06 +.07 +.08 --05 --04 -.03 -.02 --01 0.00 +.Ol +.02 +.03 +.04 +.05 +.06 +.07

-.06 --05 -.04 -.03 -.02 -.Ol +.Ol +.02 +.03 +.04 +.05 +.06 +.07 -.06 -.05 -.04 --03 -.02 --01 0.00 +.Ol +.02 +.03 +.04 +.05 +.06 --07 --06 -.05 --04 --03 -.02 -.ol 0.00 +.OI 1.02 +.03 +.04 +.05 -.07 -.06 -.05 --04 -.03 -.02 -.Ol 0.00 +.ol +.02 +.03 +.04 +.05 -.08 -.07 -.06 --05 --04 --03 --02 --01 0.00 t-01 +.02 +.03 +.04

-.08 -*07 -.06 --05 -.04 --03 --02 --01 0.00 1.01 +.02 +.03 t.04 -.09 --08 -.07 --06 --05 --04 -.03 -.02 --01 0.00 +.Ol +.02 +.03 -.I0 --09 -.08 -,07 --06 -.05 -.04 --03 -.02 -.Ol 0.00 +.Ol +.03 -.lO --09 -.08 -.07 --06 -.05 -.04 --03 -.02 -.Ol 0.00 +.Ol +.02 --II ---IO -.09 --08 -.07 --06 -.05 --04 --03 -.02 F.01 0.00 +.Ol

--II -.lO -.09 --08 -.07 --06 -.05 --04 --03 -.02 --01 0.00 +.Ol -.12 -.ll -.lO --09 --08 -.07 -.06 -.05 --04 --03 .-.02 --01 0.00 ‘-.I2 -.ll -.lO -.09 --08 -.07 -.06 --05 --04 A-03 -.02 --01 0.00 l-.13 --I2 --.I1

--12]--11 -.lO -.09 --08 -.07 -.06 -.05 e-04 -.03 v.02 -.Ol

-.I3 --lo -.09 -.09 -.08 -.07 -.06 -.05 --04 --03 -.02 I i

31 32 33 34 35

36

z 39 40

I

730 735 740 745 750 755 760 765 1 770 775 780 785 790

----_---_____,_

55

Page 60: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lA/2 000 NOMINAL CAPACITY 2 000 cm3

(Coefficient of cubical thermal expansion of glass 10 x 1O-B/oC) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/Z 000).

o-0 o-2 o-3 o-4 o-5 O-6 o-7

-

_

O-8 o-9

[IEMPE- LAT"RE. OF

VVATER t”C

5 2.57 2.57 2.57 2.57 2.58 2.58 2.58 2.58 2.59 2.59 5

f

x 10

2.60 2.60 2.60 2.61 2.61 2.62 2.63 2.63 2.64 2.65 2.65 2.66 2.67 2.68 2.68 2.69 2.70 2.71 2.72 2.73 2.74 2.75 2.76 2.77 2.78 2.79 2.80 2.82 2.83 2.84 2.85 2.87 2.88 2.89 2.91 2.92 2.94 2.95 2.97 2.98 3.00 3.01 3.03 3.04 3.06 3.08 3.09 3.11 3.13 3.15

6 7

: 10

11

:; 14 15

3.16 3.18 3.20 3.22 3.24 3.26 3.28 3.30 3:32 3.34 3.36 3.38 3.40 3.42 3.45 3.47 3.49 3.51 3.53 3.56 3.58 3.60 3-63 3.65 3.68 3.70 3.72 3.75 3.77 3.80 3.83 3.85 3.88 3.90 3.93 3.96 3.98 4.01 4.04 4.07 4.10 4.12 4.15 4.18 4.21 4.24 4.27 4.30 4.33 4.36

:: 13

if

:: 18

:t

4.39 4.42 4.45 4.48 4.51 4.54 4.58 4.61 4.70 4.74 4.77 4.80 4.84 4.87 4.90 4.94 5.04 5.08 5.11 5.15 5.18 5.22 5.26 5.29 5.40 5.44 5.48 5.52 5.55 5.59 5.63 5.67 5.79 5.82 5.86 5.90 5.94 5.98 6.02 6.07

4.64 4.67 4.97 5.01 5.33 5.37 5.71 5.75 F.11 6.15

16

:3 19 20

6.19 6.23 6.27 6.31 6.36 6.40 6.44 6.48 6.53 6.57 6.61 6.66 6.70 6.74 6.79 6.83 6.88 6 92 6.97 7.01 7.06 7.10 7.15 7.19 7.24 7,29 7.33 7.38 7.43 7.47 7.52 7.57 7.61 7.66 7.71 7.76 7.81 7.86 7.90 7.95 8.00 8.05 8.10 8.15 8.20 8.25 8.30 8.35 8.40 8.45

26 27

;i 30

8.50 8.56 8.61 8.66 8.71 8.76 8.82 8.87 9.03 9.08 9.13 9.19 9.24 9.29 9.35 9.40 9.57 9.62 9.68 9.73 9.79 9.84 9.90 9.95

LO.12 IO.18 IO.24 10.29 IO.35 10.41 IO.47 10.52 10.70 10.76 IO.81 IO.87 IO.93 10.99 11.05 11.11

8.92 8.97 9.46 9.51

10.01 10.07 10.58 10.64 11.17 11.23

I

I

,

I

,

-

11.29 11.35 Il.41 11.47 11.53 11.59 11.65 11.71 I I.90 Il.96 12.02 12.09 12.15 12.21 12.27 12.34 12.53 12.59 12.65 L2.72 12.78 12.85 12.91 12.97 13.17 13.23 13.30 13.36 13.43 13.50 13.56 13.63 13.83 13.90 13.96 14.03 14.10 14.16 14.23 14.30

11.78 11.84 12.40 12.46 13.04 13.10 13.69 13.76 14.37 14.44

36

;i 39 40

!4,50 14.57 14.64 14.71 14.78 14.85 14.92 14 99 15.19 15.27 15.34 15.41 15.48 15.55 15.62 15.69 15.90 15.97 16.05 !6.12 16.19 16.26 16.33 16.41 ‘6.62 16.70 16.77 ‘6.84 16.92 16.99 17.07 17.14 17.36 17.44 17.51 !7.59 17.66 17.74 17.81 17.89

15.06 15.13 36 15.76 15.83 37 16.48 16.55 38 17.21 17.29 39 17.96 18.04 40

56

Page 61: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 212000

NOMINAL CAPACITY 2 000 cd

Allowance for temperature and pressure of air, Add (+) to mass or subtract (-) from it,

TEMPERATURE OF AIR

“C

5

f 8 9

10

:: 13 14 15

16 17 i8

:t

2: 33 34 35

36 37 38 39 40

PRESSURE OF AIR IN mmHg

730 735 740 745 750 755 760 765 770 775 780 785 790

----__- _--_---

+.09 +.lO i.11 +.I3 +.I4 -t.16 +.I7 +.I9 1.20 +-22 +.23 3.25 +.26

+.08 +.09 +.I1 +.I2 +.14 +.I5 +.17 j-.18 +.19 +.21 +.22 +.24 +.25 +.07 +.08 +.lO +.ll +.13 +.14 +.16 +.17 1.19 +.20 +.22 +.23 +.24 +.06 i-.08 +.09 +.ll j-.12 t.13 +.15 +.16 +.18 +.lg +.21 +.22 +.24 +.05 +.07 +.08 +.lO +.I1 +.I3 +.14 +.16 +.17 +.I8 +.20 +.21 +.23 +.05 t-.06 +.07 +.09 +.lO +.12 +.I3 +.15 +.16 +.I8 +.19 1.20 +.22

+,04 +.05 +.07 +.08 +.I0 +.ll +.12 +.I4 +.I5 +.I7 +.18 +.20 -1.21 +.03 +.04 +.06 +,07 +.09 +.I0 +.12 +.13 +.I5 +.16 1.17 +.19 +.20 +.02 +.04 +.05 +.07 +.08 +.09 +.ll +.12 +.14 +.I5 +.17 t.18 +.19 +.02 i-.03 +.04 t.06 +.07 t.09 +.lO +.I1 +.13 +.14 +.I6 5.17 +.19 +.Ol 4.02 +.04 +.05 j-.06 +.08 +.Og +.ll +.12 +.I3 +.15 +.16 +.18

0.00 +.Ol +,03 +.04 +.06 +.07’+.08 +.I0 +.ll +.I3 +.I4 -1.16 +.17 -.01 +.Ol +.02 1.03 +.05 +.06 +.08 1.09 1.10 +.12 1.13 +.15 +.16 -.02 0.00 +.Ol +.03 t.04 +.05 +.07 +.08 +.lO +.ll +.12 +.14 +.15 -.02 --01 +,Ol +.02 +.03 +.05 +.06 +.08 +.09 +.I0 +.I2 +.13 +.14 -.03 -.02 0.00 4.01 +.03 -1.04 +.05 +.07 1.08 +.lO +.ll +.12 +.14

-.04 -.02 --01 0.00 +.02 +.03 +.05 +.06 +,07 +.09 +-.I0 +,I1 +.13 -.05 --03 --02 0.00 +,02 -.05

+.Ol +.04 +.05 t-.07 --04 --03

+.08 +.09 +.ll +.12 -.Ol 0.00 t.02

--:05 +.03 +.04 4.06 +.09 +.lO +.ll

-.06 --03 +.07 -.02 -.Ol +.Ol --07

f.02 +.04 +.05 -1.06 +.08 +.09 +.lO -.05 --04 -.03 -.Ol 0.00 j-.01 +.03 +.04 +.06 de.07 +.08 +.I0

-.08 -.06 --05 --03 -.02 -.Ol -.08

+.Ol +.02 +.03 +.06 +.08 +.09 -.07 --06 +.05 --04 -.03 --01 0.00

-.09 +.Ol +.03 +.04 1.05 +.07 +,08

-.08 --06 -.05 -.04 -.02 -.Ol -.lO

+.Ol -.08 -.07

+.02 +.03 +.05 +.06 +.07 -.06 --04 -.03 -.02 0.00

-.lO +..Ol +.04 +.05 +.06

-.09 --08 +.02

-.06 -.05 -,04 -.02 -.Ol 0.00 +.02 +.03 +.04 +,06

-.ll -,lO --09 -.07 --06 -.04 -.03 -.02 0.00 +,05 -.12

+.Ol 1.02 +.04 -.ll --09 -.08 -.07 -.05 A.04 -.03 -.Ol 0.00 +.Ol 5.03 +.04

-.13 -.I1 --IO --09 -.07 -.06 -.05 _.03 -.02 -.Ol +.02 +.03 -.13

+.Ol -.I2 -.I 1 -.09 -.08 --07 -.05 -.04 _.03 _.Ol 0.00 +.Ol +.03

--14 -.I3 --12 -.lO -.09 -.08 -.06 -.05 _.04 -.02 _.Ol 0.00 +.02

-.15 -.14 -.12 -.ll -.lO -.08 -.07 -.06 -.04 -.03 _.02 0.00 +.Ol -.16 -.14 -.13 -.12 A.10 -.09 _.08 -.06 _.05 _.04 -.02 -.Ol 0.00 -.16 -.15 --I4 -.I2 -.ll -.lO -.Og _.07 -.06 _.05 -.03 _-02 F-01 -.17 --.I6 -.I5 -.13 -.12 -.I1 -.Og _.08 -.07 _.05 -.04 -.03 w-01 -.I8 -.I7 --15 -.14 -.I3 -.ll _.lO -.09 _.07 _.06 -.05 -.04 _.02

57

Page 62: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lB/lOOO

NOMINAL CAPACITY 1000 cm3 (Coefficient of cubical thermal expansion of glass 15x IO-B/oC)

Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C (in conjunction with Table 2/ 1 000).

TEMPE- RATURE

WAFER tot

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9

rEMPE- ATURE

A&R tot

- -

-

I

-- - -

5 1.39 1.39 1.39 1.39 1.40 1.40 1.40 I.40 1.40 1.40 5

f 8

1:

1.40 1.40 1.41 1.41 1.41 1.41 1.41 1.42 1.42 1.42 1.43 1.43 1.43 1.44 1.44 1.44 1.45 1.45 1.46 1.46 1.46 1.47 1.47 1.48 1.48 1.49 1.49 1.50 1.51 1.51 1.52 1.52 1.53 1.54 1.54 1.55 1.55 1.56 1.57 1.58 1.58 1.59 1.60 1.61 1.61 1.62 1.63 I.64 I,65 1.65

6

5 9

10

11 12

:: 15

1.66 1.67 1.68 1.69 1.70 1.71 1.72 1.73 1.74 1.75 11 1.75 1.76 1.77 1.79 1.80 1.81 1.82 1.83 1.84 1.85 12 1.86 1.87 1.88 1.89 1.91 1.92 1.93 1.94 1.95 1.97 13 1.98 1.99 2.00 2.02 2.03 2.04 2.05 2.07 2.08 2.09 14 2.11 2.12 2.13 2.15 2.16 2.18 2.19 2.21 2.22 2.23 15

2.25 2.26 2.28 2.29 2.31 2.32 2.34 2.35 2.37 2.39 16 2.40 2.42 2.43 2.45 2.47 2.48 2.50 2.52 2.53 2.55 17 2.57 2.58 2.60 2.62 2.64 2.65 2.67 2.69 2.71 2.72 18 2.74 2.76 2.78 2.80 2.81 2.82 2.85 2.87 2.89 2.91 19 2.93 2.95 2.97 2.99 3.00 3.02 3.04 3.06 3.08 3.10 20

21 3.12 3.14 3.16 3.19 3.21 3.23 3.25 3.27 3.29 3.31 21 22 3.33 3.35 3.37 3.40 3.42 3.44 3.46 3.48 3.50 3.53 22 23 3.55 3.57 3.59 3.61 3.64 3.66 3.68 3.71 3.73 3.75 23 24 3.77 3.80 3.82 3.84 3.87 3.89 3.92 3.94 3.96 3.95 24 25 4.01 4.04 4.06 4.08 4.11 4.13 4.16 4.18 4.21 4.23 25

4.26 4.28 4.31 4.33 4.36 4.38 4.41 4.44 4.46 4.45 26 4.51 4,54 4.57 4.59 4.62 4.64 4 67 4.70 4.72 4.7: 27 4.78 4.80 4.83 4.86 4.89 4.91 4.94 4.97 5.00 5.02 28 5.05 5.08 5.11 5.14 5.16 5.19 5.22 5.25 5.28 5.31 29 5,33 5.36 5.39 5.42 5.45 5.48 5.51 5.54 5.57 5.6f 30

z: 33 34 35

5.63 5.65 5.68 5.71 5.74 5.77 5.92 5.96 5.99 6.02 6.05 6.08 6.23 6.26 6.30 6.33 6.36 6.39 6.55 6.58 6.61 6.65 6.68 6.71 6.87 6.91 6.94 6.95 7.01 7.04

5.80 5.83 5.86 5.8< 6.11 6.14 6.17 6.2f 6.42 6.45 6.49 6.5; 6-74 6.78 6.81 6.8’ 7.07 7.11 7.14 7.1;

ii 33 34 35

it 38 39 40

7.21 7.24 7.27 7.55 7.58 7.62 7.90 7.93 7.97 8.25 8.29 8.32 8.62 8.65 8.69

7.31

;:;; 8.3E 8.72

7.34 7.38 7.65 7.72 8.04 8.07 84C 8.43 8.7E 8.80

/

I

-

7.41 7.44 7.48 7.51 7.76 7.79 7.83 7.8t 8.11 8.15 8.18 8.2: 8.47 8.51 8.54 8.5f 8.84 8.88 8.91 8.9:

36 37

;z 40

58

Page 63: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE W/l 000 NOMINAL CAPACITY 1000 cm3

(Coefficient of cubical thermal expansion of glass 25x 10-6/“C) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/l 000).

TEMPE-

RATURE

GER

tot 0-O O-1 o-2 0.3 o-4 o-5 O-6 O-7

1.61 1.61 1.61 1.61 1.61 1.61 1.61 1.61 1.61 1.61

1.61 1.61 1.61 1.61 1.62 1.62 1.62 1.62 1.62 1.62 1.63 1.63 1.63 1.63 1.64 1.64 1.64 1.64 1.65 1.65 1.65 1.66 1.66 1.67 1.67 1.67 1.68 1.68 1.69 1.69 I.70 1.70 1.71 1.71 1.72 1.72 1.73 1.73 1.74 1.75 l-75 1.76 1.77 1.77 1.78 1.79 1.79 1.80 1.81 1.81

1.82 1.83 1.84 1.85 1.85 1.86 1.87 1.88 1.89 1.90 1.90 1.91 1.92 1.93 1.94 1.95 1.96 1.97 1.98 1.99 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.09 2.10 2.11 2.12 2.13 2.14 2.15 2.17 2.18 2.19 2.20 2.21 2.23 2.24 2.25 2.27 2.28 2.29 2.30 2.32 2.33 2.35

2.36 2.37 2.39 240 2.41 2.43 2.44 2.50 2.52 2.53 2.55 2.56 2.58 2.59 2.66 2.67 2.69 2.70 2.72 2.74 2.75 2.82 2.84 2.86 2.87 2.89 2.91 2.93 3.00 3.02 3.03 3.05 3.07 3.09 3.11

‘2’:: 2177 2.94 3.13

2.47 2.49 2.62 2.64 2.79 2.80 2.96 2.98 3.15 3.16

3.18 3.20 3.22 3.24 3.26 3.28 3.30 3.32 3.34 3.36 3.38 3.40 3.42 3.44 3.46 3.48 3.50 3.52 3.55 3.57 3.59 3,61 3.63 3.65 3.67 3.70 3.72 3.74 3.76 3.78 3.80 3.83 3.85 3.87 3.89 3.92 3.94 3.96 3.99 4.01 4.03 4.05 4.08 4.10 4.12 4.15 4.17 4.20 4.22 4.24

4.27 4.29 4.32 4.34 4.36 4.39 4.41 4.44 4.46 4.49 4.51 4.54 4.56 4.59 4.61 4.64 4.66 4.69 4.72 4.74 4.77 4.79 4.82 4.85 4.87 4.90 4.92 4.95 4.98 5.00 5.03 5.06 5.09 5.11 5.14 5.17 5.19 5.22 5.25 5.28 5.30 5.33 5.36 5.39 5.42 5.44 5.47 5.50 5.53 5.56

5.59 5.61 5.64 5.67 5.70 5.73 5.76 5.79 5.82 5.85 5.88 5.90 5.93 5.96 5.99 6.02 6.05 6.08 6.11 6.14 6.17 6.20 6.23 6.26 6.30 6.33 6.36 6.39 6.42 6.45 6.48 6.51 6.54 6.57 6.61 6.64 6.67 6.70 6.73 6.76 6.79 6.83 6.86 6.89 6.92 6.96 6.99 7.02 7.05 7.09

7.12 7.15 7.18 7.22 7.25 7.28 7.32 7.35 7.38 7.42 7.45 7.48 7.52 7.55 7.58 7.62 7.65 7.68 7.72 7.75 7.79 7.82 7.86 7.89 7.92 7.96 7.99 8.03 8.06 8.10 8.13 8.17 8.20 8.24 8.27 8.31 8.35 8.38 8.42 8.45 8.49 8.52 8.56 8.60 8.63 8.67 8.70 8.74 8.78 8.81

O-8 0’9

?EMPE-

ATURE

NZR

tot

5

:: 13 14 15

16 17

:: 20

36 37

z: 40

59

Page 64: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/l-5

NOMINAL CAPACITIES l-5 cm3

(Coefficient of cubical thermal expansion of glass 30 ,,< lO-B/“C)

Add to mass (grams) of pure water at t°C to obtain capacity of vessel at 27°C.

TEMPERATURE OF WATER

t”C

NOMINAL CAPACITY. cd

1 2 3 4 5

TEMPERATURE OF WATER

tT _ _L

5 0.001 7 0.003 4 0.005 2 0.006 9 0,008 6 5

f 8

1:

0.001 7 0.003 4 0.005 2 0.006 9 0.008 6 0.001 7 0.003 5 0.005 2 0,006 9 0.008 6 0.001 7 oXnI3 5 0.005 2 0,007 0 0,008 7 0.001 8 0.003 6 0.005 4 0.007 1 0.008 9 0.001 8 0.003 7 0.005 5 0.007 3 0.009 2

6 7

! 10

:: 13

0.001 9 0.003 8 0.005 7 0,007 6 0.009 5 0.002 0 0.004 0 0.005 9 0.007 9 0,009 9 0.002 1 0.004 1 0.006 2 0.008 3 0.010 3 0.002 2 0.004 3 0.006 5 0.008 7 0.010 9 0.002 3 0.004 6 0.006 9 0,009 1 0.011 4

:: 13

:; :s E :x 20

2: 23 24 25

26 27

z 30

31 32 33

S f

0,002 4 0.004 8 0.007 2 0.009 7 0.012 1 0.002 6 0,005 1 0.007 7 0.010 2 0.012 8 0.002 7 0.005 4 0.008 1 0.010 8 0.013 5 0.002 9 0.005 7 0.008 6 0.011 4 0.014 3 0.003 0 0.006 1 0.009 1 0.012 1 0.015 2

0.003 2 0.006 4 0.009 6 0,012 9 0,016 1 0.003 4 0.006 8 0.010 2 0.013 6 0.017 0 0.003 6 0.007 2 0.010 8 0.014 4 0.018 0 0.003 8 0.007 6 0.011 5 0.015 3 0.019 1 0.004 0 0.008 I 0~012 1 0,016 2 0.020 2

0.004 3 0.008 5 0,012 8 0.017 1 0.021 4 0.004 5 0.009 0 0.013 5 0.018 1 0.022 6 0.004 8 0.009 5 0.014 3 0.019 1 0.023 8 0.005 0 0.010 0 0.015 1 0.020 1 0.025 1 0~005 3 0.010 6 0,015 9 0.021 2 0.026 4

0.005 6 0.011 1 0.016 7 0,022 3 0,027 8 0.005 9 0.011 7 0.017 6 0.023 4 0.029 3 0.006 1 0.012 3 0.018 4 0.024 6 0,030 7 0.006 4 0.012 9 0.019 3 0.025 8 0.032 2 0.006 8 0,013 5 0.020 3 0.027 0 0.033 8

0.007 1 0.014 1 0.021 2 0.028 3 0.035 4 0.007 4 0.014 8 0.022 2 0.029 6 0.037 0 0.007 7 0.015 5 0.023 2 0,030 9 0.038 7 0.008 1 0.016 1 0.024 2 0.032 3 0.040 4 0.008 4 0.016 8 0,025 3 0,033 7 0.042 1

-

-

16

:i 19 20

21 22 23

ft

26

;i 29 30

36 37 38

60

Page 65: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TABLE lD/6 TABLE lD/7

NOMINAL CAPACITY 6 cm3 (Coefficient of cubical thermal expansion

of glass 30 x lo-s/‘C) Add to mass (grams) of pure water at t”C

to obtain capacity of vessel at 27°C (in conjunction with Table 2/6).

NOMINAL CAPACITY 7 cm3 (Coefficient of cubical thermal expansion of

glass 30 x IO-s/V) Add to mass (grams) of pure water at t”C to

obtain capacity of vessel at 27°C (in conjunction with Table 2/7).

TEMPERAXIRE OF WATER TEMPERATURE OF WATER

0.0 o-5

0.010 0.010

0.010 0.010 0.010 0.011 0.011

0.010 0,010 0.011 0.011 0.011

0.011 0.012 0.012 0.013 0.014

0.012 0.012 0.013 0.013 0.014

0.014 0.015 0.015 0.016 0.016 0.017 0.017 0.018 0.018 0.019

0.019 0.020 0.020 0.021 0.022 0.022 0.023 0,024 0.024 0.025

0.026 0.026 0.027 0,028 0.029 0.029 0.030 0.031 0.032 0.033

0.033 0.034 0.035 0.036 0.037 0.038 0.039 0.040 0.041 0.041

0.042 0.043 0.044 0,045 0.046 0.047 0.048 0,049 0.051 0.052

r

IS : 8897 - 1978

0.012 0,012

0.012 0.012 0.012 0.013 0.013

0.012 0,012 0,012 0.013 0.013

0,013 0.014 0.014 0.014 0.014 0.015 0.015 0.016 0.016 0.016

0.017 0.018 0.019 0.020 0.021

0.017 0.018 0.019 0.021 0.022

0.022 0.023 0,024 0,025 0.025 0.026 0.027 0.028 0.028 0.029

0.030 0.031 0.032 0.032 0.033 0.034 0.035 0.036 0.037 0.038

0.039 0,040 0.041 0.042 0.043 0,044 0.045 0.046 0.047 0,048

0.050 0.051 0.052 0.053 0.054 0.055 0.057 0.058 0.059 0.060

o-5

61

Page 66: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 10/t? TABLE lDj9 NOMINAL CAPACITY 8 cm3 NOMINAL CAPACITY 9 ems

(Coefficient of cubical thermal expansion of (Coefficient of cubical thermal expansion of glass 30 X lOW/oC) glass 30 x IO-s/%)

Add t,o mass (grams) of pure water at t”C to Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C obtain capacity of vessel at 27°C (in conjunction with Table 2/8). (in conjunction with Table 2/9).

TEMPERATURE OF WATER TEMPERATURE OF WATER

tot 0’0

5 0.014

f

t 10

0.014 0,014 0.014 0.014 0.015

:: 13 14 15

0.015 0.016 0.017 0.017 0.018

16 17 18

:t

0.019 0.020 0.022 0.023 0.024

21 22

z 25

0.026 0,027 0.029 0.031 0.032

0,034 0.036 0.038 0,040 0.042

31 0.045 32 0.047 33 0.049 34 0,052 35 0.054

36 0.057 37 0.059 38 0.062 39 0.065 40 0.067

0.5 tot

0.014

0.014 0.014 0.014 0.014 0.015

0.016 0.016 0.017 0.018 0.019

0,020 0,021 0~022 0.024 0.025

0.026 0.028 0.030 0.031 0.033

0.035 0.037 0.039 0.041 0.043

0.046 0,048

;:;;; o-055

0.058 0.061 0.063 0.066 0.069

5

11

:z

:s

16 17 i8 19 20

2j 24 25

31 32 33

-

-_ 0-O

O.OlF

0.015 0,016 0.016 0.016 0,017

0.017 0,018 0.019 0.020 0.021

0.022 0.023 0.024 0.026 0.027

0,029 0.031 0.032 0.034 0.036

0.038 0.041 0.043 0.045 0.048

0.050 0.053 0.055 0.058 0.061

0.064 0.067 0.070 0.073 0.076

o-5

0.015

0.015 0,016 0.016 0.016 0.017

0.017 0.018 0.019 0.020 0.02 1

! 0.022 0.024 0.025 0.027 0.028

0.030 0.032 0.033 0.035 0.037

0.040 0.042 0.044 0.046 0.049

0.051 0,054 0.057 0.059 0.062

0.065 0.068 0.071

62

Page 67: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TABLE lD/lO TABLE lD/ll

NOMINAL CAPACITY 10 cm3 NOMINALCAPACZTYllcm" (Coefficient of cubical thermal expansion of (Coefficient of cubical thermal expansion of

glass 30 X 1O--B/0G) glass 30 x IO-s/‘C) Add to mass (grams) of pure water at t”C to Add to mass (grams) of pure water at t”C to

obtain capacity of vesssel at 27°C obtain capacity of vessel at 27°C (in conjunction with Table 2110). (in con.junction with Table 2/l 1).

TEMPERATURE OF WATER TEMPERATURE OF WATER

t”C

5

:: 13 14 15

:s 18

::

26 27 28

zt

31 32 33

z

36

z: 39 40

0-O

0.017

0.017 0.017 0.017 0.018 0.018

0.019 0~020 0.021 0,022 0.023

0.024 0.025 0.026 0.026 0.027 0.028 0.029 0.029 0,030 0,031

0.032 0.033 0.034 0.035 0.036 0,037 0,038 0.039 0,040 0.042

0.043 0.044 0.045 0.046 0.048 0049 0050 0.052 0.053 0,054

0.056 0.057 0.059 0.060 0.061 0.063 0.064 0.066 0.068 0.069

0.071 0.072 0.074 0.076 0.077 0.079 0.081 0.082 0.084 0.086

05

IS : 8897 - 1978

tot

0.017

0,017 0.017 0.018 0.018 0.019

0.019 0.020 0.021 0.022 0.023

5

f

: 10

16 17

:t 20

21

xz 24 25

St 38 39 40

0-O

0.019

0.019 0.019 0.019 0,020 0.020

0.021 0,022 0,023 0.024 0.025

0.027 0.027 0.028 0.029 0,030 0.031 0.031 0.032 0.033 0.034

0.035 0,036 0.037 0.039 0.040 0.041 0.042 0.043 o-044 0.046

0.047 0.048 0.050 0.051 0.052 0.054 0.055 0.057 0.058 0.060

0.061 0.063 0.064 0.066 0.068 0.069 0.071 0.073 0.074 0.076

0.078 0.080 0.081 0.083 0.085 0.087 0.089 0.091 0.093 0,095

0.5

0.019

0.019 0,019 0.019 0.020 0,021

0.021 0,022 0.023 0,025 0,026

63

Page 68: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/15

NOMINAL CAPACITY 15 cm3

(Coefficient of cubical thermal expansion of glass 30x lO-E/C)

Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C (in conjunction with Table 2/15).

tot

TEMPERATURE OF WATER

14 15

16

:5 19 20

21

;z 24 25

0.0

0,026 0.026

0.026 0,026 0.026 0,026 0.026 0.026 0.027 0.027 0,028 0,028

0,029 0.029 0.030 0.030 0.031 0.032 0.033 0.033 0.034 0.035

0.036 0.037 0.038 0.039 0.041 0.042 0,043 0.044 0.045 0.047

0.048 0.050 0.051 0.053 0.054 0,056 0.057 0.059 0.061 0.062

0.064 0.066 0.068 0.070 0.071 0.073 0.075 0.077 0.079 0.081

0.083 0.086 0.088 0.090 0.092 0.094 0.097 0.099 0.101 0.104

0.106 0.109 0.111 0.113 0.116 0.119 0.121 0.124 0.126 0.129

64

o-5

Page 69: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/20 NOMINAL CAPACITY 20 cm3

(Coefliciellt of cu bical thermal expansion of glass 30 x lo-s/‘C) .qdd to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/:

r 0.9

0,031

0.034 0.03: 0.03: 0.03c 0.03E

0.03s 0.041 0.043 0.045 0.047

3.050 3.053 I.056 I.060 I.063

I.067 I.071 j.075 I.079 j.084

LO89 I.094 I.099 I.104 I.110

I.115 I.121 1.127 I.133 I.140

I.146 I.153 I.159 I.166 I.173

-

-I

4

' / , 1

I

( ( I ( (

(

I

i

C

:

:

:

: 0

-

-

-~

4

3 1 , c i

-

o-3 o-4 0.5 O-6

-.

0.03‘ 4 0.03‘

-_

1 0.032 0.03<

0.03‘ 0.03! 0.03! 0.03( 0.03:

0.03‘ 0.03: 0.03: 0.03t 0.03:

0.031 0.03: 0.03: 0.03f 0.03;

0.034 0.03: 0.03: 0.03t 0.03;

0.03t 0.04( 0.04; 0.044 0.04E

I , k i

0.03s 0.04( 0.04; 0.044 0,047

0.035 0.04( 0.041 0.04: 0.045

I ! i 1 ’ ,

0*03I 0.041 0.043 0.045 0.047

0.045 o-052 0.055 0.058 3.062

0.049 0.052 D.055 D.059 3,062

0.050 0.052 D.056 3.059 3.062

D.050 D.053 3.056 3.059 I.063

3.065 I.069 I.073 I.078 I.082

I 066 I.070 I.074 I.078 I.083

I.066 I.070 I.074 I.079 I.083

I.067 I.071 I.075 I.079 I.084

I.087 I.092 I.097 I.102 I.107

I.087 I.092 I.097 I.103 I.108

j.088 bO93 bO98 ).I03 I.109

j.088 bO93 I.098 b 104 I.109

).I13 I.119 ). 125 b.131 I.137

I.114 ).I19 ). 125 I.131 I.138

I.114 j.120 I.126 I.132 I.138

1,115 I.121 I.126 I.133 I.139

I.143 I.150 I.157 I.164 I.171

I.144 I.151 I.157 1.164 I.171

I.145 I.151 I.158 1,165 1.172

I.145 I.152 I.159 I.166 I.173

TEMPE- RATURE

u&t t”C

0-O O-1 o-2

0.03,

0.03‘ 0.03! 0.03! 0.03( 0.03:

0.03( O-04( 0.04; 0.044 0.04t

0.04s 0.052 0.055 0.058 3.061

3.065 3,069 3.073 I.077 3.082

I.086 I.091 I.096 I.101 I.107

). 112 j.118 l-124 I.130 t.136

I.143 I.149 I.156 1,163 I.170

0%

5 0.03,

0.03‘ 0.03: 0.03! 0.03( 0.03’

11 12

:: 15

0.031 0.04( 0.041 0.04: 0.04f

16 0.04t 17 0.051 18 0.054 19 0.057 20 D.061

:; 23 24 25

$064 1.068 3.oi2 I.076 3.081

26 1,085 27 I.090 28 1.09.5 29 ),lOO 30 I.106

31

332 34 35

I.111 ).I17 ). 123 I.129 I.135

36 I.141 37 I.148 38 I.155 39 I.161 40 1.168

0.03‘

0.03‘ 0.031 0.031 0.031 0.03’

0.031 0.04( 0.04; 0.044 0.04t

0.045 0.051 0.054 0.058 3.061

1.065 3,069 3.073 3.077 I.081

I.086 1091 I.096 I.101 I.106

).I12 j.118 b.123 ).I30 I.136

I.142 I.149 I.155 I.162 I.169

0.03, 0.03. 0.031 0.03' 0.031

D.O3! 0.04 D.04: 3.04: 3.04t

1.05( 1.05: 1.05; &06( I.064

1.067 j.071 ).07E kO8C I.085

I.089 I.094 I.099 I.105 I.110

I.116 I.122 1.128 I.134 I.140

I.147 I.153 1.160 1.167 ,174

0.03

0.03, 0.03. 0.031 0.03' 0.031

X:E 0.041 0.04t 0.04t

0.051 0.05L 0.05; 0.06( 0.064

0.06P 0.072 0.076 0.080 D.085

3.090 1095 I.100 I.105 I.111

I.116 I.122 I.128 I.134 I.141

I.147 I.154 I.161 I.168 I.175

65

Page 70: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/25 NOMINAL CAPACITY 25 cd

(Coefficient of cubical thermal expansion of glass 30 x IO-*/‘C) opacity of vessel at 27°C Add to mass (grams) of pure water at t”C to obtain ca

(in conjunction with Table 2/2i 5).

TEMPE- RATURE

WYZ~R tot

5

11 12

:: 15

16 17

:t 20

f : 23 24 25

26 27 28

ii

31

3: 34 35

39 38 39 40

O-0 0.1

I.043

3.043 I.043 3.043 I.043 3.044 I.044 3.045 3.045 D.046 3.046

0.048 D.048 0.049 0.050 0.052 D.052 D-054 D.055 0.057 0.057

0.060 D.061 0.064 0.064 0.068 0.068 0.072 0.072 0.076 0.07E

0.080 0.081 0.085 0.08C 0.090 0.091 0.095 0.09t 0.101 0.10:

0.107 o-10: o-113 0.11: 0.119 0.12( 0.126 0.12( 0.132 0.131

0.139 0.14( 0.146 0.14: 0.154 0.15‘ 0.161 0.16: 0.169 0.17(

0.177 0.17{ 0.185 0.18t 0.193 0.194 0.202 0.20: 0.211 0.211

I.043 J.043 j.043 0.043 D.043 I.043 I.043

-

( I.043

I.043 I.043 I.043 0.043 0.043 3.043 I.043 ( I.043 I.043 I.043 I.043 0.043 0.043 D-044 I.044 ( I.044 I.044 I.044 I.044 0.044 0,044 D.044 3.044 ( I.045 I.045 I.045 I.045 0.045 0.045 0.046 3.046 ( I.046 3.046 I.046 1.047 0.047 0.047 0.047 3.047 ( I.047

3,048 I.048 I.048 0.048 0.049 0.049 3.049 I 3.049 3.050 I.050 I.050 0.051 0.051 0.051 D.051 I 3.052 3.052 I.052 I.053 0.053 0.053 0.054 D.054 I 3.054 3.055 I.055 I.055 0.056 0.056 0.056 0.057 I 3.057 3.058 I.058 I.058 0.059 0.059 0,059 0.060 I I I.060

D.061 3.061 3,062 0.062 0.062 0.063 0.063 ; I 3.063 0.065 3.065 3.065 0.066 0.066 0.066 0.067 I 0.067 0.068 D.069 3.069 0.069 0.070 0.070 0.071 I 0.071 0.072 D.073 D.073 0.074 0.074 0.074 0.075 , I 0.075 0.077 0.077 D.078 0.078 0.078 0.079 0,079 I I 0.080

0.081 0.082 D.082 O-083 0.083 0,084 0.084 , 0.08.i 0.086 0.087 0.087 0.088 0.088 0.089 0.085 I 1 0.090 0.091 0.092 0.092 0.093 0.093 0.094 0.094 r 1 0.095 0.097 0.097 0.098 0.098 0.099 0.099 O.lOC I 0.100 0.102 0.103 0.103 0.104 0.104 0.105 O.lOE i 0.106

0.108 0.109 0.109 0,110 0.110 0.111 0.112 0.114 0.115 0.115 0.116 0.117 0.117 O.llE 0.120 0.121 0.122 0.122 0.123 0.124 0.124 0.127 0.128 0.128 0,129 0.130 0,130 0.131 0.134 0.134 0.135 0.136 0.136 0,137 0.13E

0.112 0.11e 0.12: 0.132 0.13E

0.141 0.141 0.142 0.143 0.143 0.144 0.14E 0.148 0.148 0.14s 0.15a 0.151 0.151 0.15: 0.155 0.156 0.155 0.157 0.158 0.159 0.16( 0.163 0.163 0.164 0.165 0.166 0.167 0.16; 0.170 0.171 0.172 0.173 0.174 0.174 0.17!

0.14f 0.15: 0.16C 0.16E 0.17C

0.178 0.179 0.18C 0.181 0.182 0,183 0.18: 0.187 0.187 0.18E 0.189 0.190 0.191 0.19: 0.195 0.196 0.197 0.198 0.198 0.199 0.20( 0.204 0.204 0.20: 0.206 0.207 0,208 0.205 0.212 0.213 0.214 0.215 0.216 0.217 0.21f

1

i

f

-

0.184 0.19; 0.201 0.21( 0.215

o-3 o-4 0’5 O-6 @7 0.8

-

O-9

'EMPE- ATURE

VAZR tot

5

if 18 19 20

26 27

z: 30

31

z: 34 35

36

zi 39 40

66

Page 71: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/30 NOMINAL CAPACITY 30 cm3

(Coefficient of cubical thermal expansion of glass 30 x 10-B/“C) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/30).

0.05:

0.05: 0.05: 0.05: 0~0~ 0.05!

0.05: 0.05: 0.06: 0.06! 0*06!

0.07: 0.07; 0.081 0.08t 0.091

0.09E 0.102 0.1oe 0.115 0.121

0.128 0.135 D. 143 3.151 3.159

I.167 3.176 3.184 1.193 I.203

I.212 I.222 I.232 I.242 I.253

O-1

0.05:

0.05: 0.05: 0.05: 0.05 0.05!

0.05: 0.06( 0.06: 0.06! 0.06s

0.07: 0.07; 0.081 0.08E 0.091

0.097 0.103 0.109 0.115 0.122

0.129 D.136 3.144 3.151 I.159

I.168 I.176 I.185 I*194 I.204

I.213 I.223 I.233 I.243 I.254

0.2

0.05:

0.05: 0.05: 0.05: 0.05‘ 0.05!

0.05: 0.06( 0.06: 0.06t 0.065

0.07: 0.07; 0.082 0.08i 0.092

0.098 0.103 0’109 0.116 0.123

0.130 3.137 1.144 I.152 I.160

I.169 I.177 I.186 I.195 I.205

I.214 I.224 I.234 I.244 I.255

-

2

0.3

0.05:

0.05: 0.05: 0.05: 0.05L 0.05(

0.05t 0.06( 0.06: 0.06( 0.07(

0.074 0.07E 0.082 0.08; 0.093

0.098 0.104 0.110 0.117 0,123

3.130 3.138 I.145 I.153 I.161

I.169 I.178 I.187 I.196 I.205

I.215 I.225 I.235 I.245 I.256

0.05:

0.05: 0.05: 0.05: 0.051 0.05t

0.05t 0.06( 0.06: 0.06; 0.07(

0.074 0.07E 0.083 0.088 0.093

D.099 D. 105 0.111 D.117 0.124

3.131 I.138 I.146 I.154 I.162

I.170 I.179 I.188 I.197 I.206

I.216 I.226 I.236 j-246 j.257

0.05:

0.05: 0.05: 0.05: 0.05‘ 0.05(

0.05t 0.061

“0% 0.071

0.074 0.07s 0.083 0.088 0.094

3.099 3.105 D.111 3.118 3.125

1,132 I.139 I.147 I.155 I.163

I.171 I.180 I.189 1.198 I.207

j-217

%: I.247 I.258

0.05:

0.05: 0.05: 0.051 0.05‘ 0.05t

0.05E 0.061 0.064 0*06i 0.071

0.075 0.079 0.084 D.089 D.094

3.100 1.106 3.112 I.119 I.125

I.132 I.140 1,148 I.155 I.164

I.172 I.181 I.190 I.199 I.208

I.218 I.228 t-238 I.248 I.259

0.05:

0.05: 0.05: 0.05: 0.05: 0.05f

0.055 0.061 0.064 0.06E 0.071

0.075 0.080 0.084 3.089 3.095

3.100 I.106 1.113 I.119 I.126

I.133 I.141 I.148 b.156 I.164

I.173 k 182 I.191 I.200 I.209

I.219 I.229 1.239 I.250 I.260

0.8

-

0.05

0.05 0.05 0.05 0.05 0.05

0.05! 0.06: 0.06! 0.061 0.07:

D.07( 3.08( 3.081 3.09( 1.09f

I.101 1.10; 1.11: ).12( 3.12;

I.134 ).I41 ).I49 I.157 I.165

I.174 I.183 I.192 I.201 I.210

I.220 1.230 I.240 1.251 8.261

o-9

-

0.05

0.05 0.05 0.05 0.05. 0.05’

0.05! 0.06: 0.061 0.061 0.07:

D.07(

:‘::j . c 1.09i 1.09t

1.10s FlOE I.114 I.121 I.127

I.135 I.142 I.150 I.158 I.166

I.175 I.183 I.192 I.202 .211

.221

.231

.241

.252 *262

67

Page 72: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/40

NOMINAL CAPACITY 40 ems (Coefficient of cubical thermal expansion of glass 30 x IO-*/%)

Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C (in conjunction with Table 2146).

TEMPE- RATURE

WZR

tT4

0-O O-1 o-2 o-3 o-4 o-5 O-6 o-7 0’8 0.9

- _

5 0.069 0.069 0.069 0.069 0.069 O.OG9 0.069 O.OF9 0.069 0,069

0.069 0.069 0.069 0,069 0.0&9 0,069 0.069 0.069 0.069 0,069 0,069 0.069 0.069 0.069 0.069 0.069 0.070 0.070 0,070 0.070 0.070 0.070 0.070 0.070 0.070 0.071 0.071 0,071 0,071 0.07 1 0,071 0.072 0.072 0.072 0.072 0.072 0.073 0.073 0.073 0.073 0.073 0.074 0.074 0,074 0.074 0.075 0.075 0,075 0.076 0.076

11 12

ii 15

0.076 0.076 0.077 0.077 0.077 0.078 0.078 0.078 0.079 0,079 0.079 0.080 0.080 0.080 0.081 0.081 0.081 0,082 0.082 0.082 0.083 0.083 0.084 0.084 0.084 0.085 0.085 0.086 0.086 0,086 0.087 0.087 0.088 0.088 0.089 0.089 0.090 0.090 0,091 0.091 0.091 0.092 0,092 0.093 0.093 0.094 0.094 0,095 0.095 0.096

16 17

:B 20

0.097 0.097 0.098 0.098 0.099 0,099 0.100 0,100 0.101 0.101 0.102 0.103 0.103 0.104 0.104 0.105 0.106 0,106 0.107 0.107 0.108 0,109 0.109 0.110 0.111 0,111 0.112 0.112 0.113 0.114 0.114 0.115 0.116 0,116 0.117 0.118 0,119 0.119 0.120 0.121 0.121 0.122 0.123 0.123 0,124 0.125 0.126 0.126 O-127 0,128

21 22 23

$2

0.129 0.129 0.130 0.131 0.132 0,132 0,133 0,134 0,135 0, 135 0: 136 0.137 0.138 0.139 0.139 0.140 0.141 0.142 0.143 0,143 0.144 0.145 0.146 0.147 0.148 0.148 0.149 0.150 0.151 0.152 0.153 0.154 0.155 0.155 0.156 0.157 0,158 0.159 0,160 0,161 0.162 0.163 0.163 0.164 0.165 0.166 0,167 0,168 0.169 0.170

0.171 0.172 0.173 0.174 0.175 0.176 0.177 0.178 0.179 0,180 0.181 0.182 0.182 0.183 0,184 O-185 0.186 0.187 0.188 0,189 0.191 0.192 0.193 0.194 0.195 0.196 0,197 0.198 0.199 0,200 0.201 0.202 0.203 0.204 0.205 0.206 0.207 0.208 0.209 0,210 0.212 O-213 0.214 0.215 0.216 0.217 0.218 0.219 0.220 0.221

31

:z 34 35

0.223 0.224 0.225 0.226 0.227 0.234 0,235 0.236 0,237 0,239 0.246 0.247 0.248 0.249 0,251 0.258 0.259 0.260 0,261 0.263 0.270 0,271 0.273 0,274 0.275

8:;:;

0.252 0.264 0.277

0.229 0.231 0.232 0.233 0.241 0.242 0.243 0.245 0.253 0.254 0.255 0.257 0.265 0.266 0.268 0.269 0.278 0.279 0.280 0,282

36 0.283 0,284 0.286 37 0,296 0.297 0.299 38 0.309 0.311 0,312 39 0.323 0.324 0.326 40 0.337 0.338 0.340

0.287 0.288 0,289 0.291 0,292 0.293 0.295 0.300 0.301 0.303 0.304 0.305 0.307 0.308 0.313 0.315 0.316 0.317 0.319 0.320 0.322 0.327 0.329 0,330 0.331 0.333 0.334 0,336 0.341 0.343 0.344 0.345 0.347 0.348 0.350

hMPE-

<ATURE

W%R

tOc

:: 15

16 17

:i 20

21

f3 24 25

E 28

E 31 32 33

68

Page 73: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/50 NOMINAL CAPACITY 50 cm3

(Coefficient of cubical thermal expansion of glass 30 x 10-B/oC) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/50).

TEMPE-

RATLJKE

W%R

t”C

-

-_ --

5 0.086 0.086 0.086 0.086 0.086 0.086 0.086 0,086 0.086 0.086 5

f 8

13

0.086 0.086 0.086 0.086 0,086 0.086 0.086 0.086 0.086 0.086 0.086 0.086 0.08G 0.087 0.087 0.087 0.087 0.087 0.087 0.087 0.087 0.088 0,088 0.088 0.088 0.088 0.088 0.089 0.089 0.089 0.089 0.090 0.090 0.090 0.090 0.091 0.091 0.091 0.091 0.092 0.092 0.092 0,092 0.093 0.093 0.093 0.094 0.094 0.094 0.095

:: 13

::

0.095 0.095 0.096 0.096 0.097 0.097 0.097 0.098 0,099 0.099 0.100 0.100 0.101 0.101 0.102 0.102 0.103 0.104 0.104 0.105 0.105 0.106 0.106 0.107 0.109 0.109 0.110 0.110 0.111 0.111 0.112 0.113 0.114 0.115 0.116 0.116 0,117 0.117 0,118 0.119

KZ 0.108 0.113 0.119

0.099 0.103 0.108 0.114 0.120

::

:: 15

16 17

:: 20

0.121 0.128 0.135 0,143 0.152

0.121 0.122 0.123 0.123 0.124 0.125 0.125 O.i26 0.127 0.128 0.129 0.130 0.131 0.131 0.132 0.133 0.134 0.134 0.136 0.137 0.137 0.138 0.139 0.140 0.141 0,141 0.142 D, 144 0.145 0.146 0.146 0.147 0.148 0.149 0.150 0.151 0.152 0.153 0.154 0 15.5 0.156 0.157 0.158 0.159 0.160

16

:: 19 20

0.161 0.170 0.180 0.191 0,202

0.162 0.163 0.164 0,164 0.165 0.166 0.167 0.168 0.169 21 0.171 0.172 0.173 0.174 0.175 0.176 0.177 0.178 0.179 22 0.181 0.182 0.184 0.185 0.186 0.187 0.188 0.189 0.190 23 D.192 0.193 0.194 0.195 0.196 0.198 0.199 0.200 0.201 24 0.203 0.204 0.205 0.207 0.208 0.209 0.210 0.211 0.212 25

0.214 0.226 D.238 0.251 0.264

0.215 0.216 0.217 0.218 0.220 0.221 0,222 0.227 0,228 0.229 0,231 0.232 0.233 0.234 0.239 D.241 0.242 0.243 0.245 0.246 0,247 0.252 0.254 0.255 0.256 0.258 0.259 0,260 3.266 3.267 D.269 D.270 0.271 0.273 0.274

0.223 0.236 0.248

8:;;;

0.224 0.237 0.250 0.263 0.277

31 32 33 34 35

0.278 3.293 0,307 0.322 3.338

D.280 3.281 0.282 D.284 0.285 0.287 0.288 0.290 0.291 3.294 3.295 3.297 0.298 0.300 0.301 0.303 0.304 0.306 3.309 3.310 3.312 D.313 0.315 0.316 0.318 0.319 0.321 3.324 3,325 3.327 D.328 0.330 0.332 0.333 0.335 0.336 3.339 3.341 3.342 3,344 0,346 0.347 0.349 0.350 0.352

z 33 34 35

/ / , , ,

I

,

I

I

I

I

I

I

I

I

I

I

I

I

I

D.354 3.370 3.387 3.404 D.421

/ I

,

,

I

,

I

I

I

I

I

I

I

I I I I

t

I I

t f

3.355 1,357 3.359 3.360 0.362 0.363 0.365 0.367 0.368 3.372 I.373 3.375 3.377 0.378 0.380 0.382 0.383 0.385 3.388 I.390 1.392 3.393 0.395 0.397 0.399 0.400 0.402 3.405 MQ7 I.409 3.411 0.412 0.414 0.416 0.418 0.419 3.423 3.425 3.426 3.428 0.430 0.432 0.434 0.435 0.437

36

z 39 40

0.0 O-1 0.2 0.3 0.4 o-5 O-6 o-7 O-8 o-9

GMPE-

XATURE

WSER

tot

69

Page 74: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE ID/60

NOMINAL CAPACITY 60 cm3 (Coefficient of cubical thermal expansion of glass 30 x 10-s/“C)

Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C (in conjunction with Table 2/60).

TEMPE- RATURE

WZER tot

0-O

I.103 I.103 I.103 I.103 I.103 I.103

.-

(

( ( ( ( t

I ( I

I

I

I

I

/

,

,

/

I.103 I.103

I-103 3.103 1,103 I.103 I.103 I.104 3.104 I.104 I.104 I.104 I.105 3.105 3.105 I.106 I.106 3.107 3.107 3.108 I.108 I.108 3.110 3.111 3.111 I.111 3.112

I.103 I.103 I.103 I.104 I.104 I.104 I.106 I.106 I.106 3.109 I.109 I.109 I.112 I.112 I.113

D.114 D.115 D.115 3.115 3.116 3.119 3.119 3.120 I.120 3.121 0.124 0.125 3.125 3.126 3.127 Cl.130 0.131 D.132 3.132 0.133 0.137 0.138 D.139 0.139 0.140

3.116 3.117 I.117 3.121 I.122 I.122 D.127 3.128 3.128 3.134 3.134 3.135 D.141 3.142 I.142

I.118 I.123 I.129 I.136 I.143

0.145 0.146 0.146 0.147 0.148 0.153 0.154 0.155 0.156 0.157 0.162 0.163 0.164 0.165 0.166 0.172 0.173 0.174 0.175 0.176 0.182 0.183 0.184 0.185 0.186

0.149 0.150 3.151 I.151 0.157 0.158 3.159 I.160 0,167 0.168 3.169 I.170 0.177 0.178 D.179 3.180 0.187 0.188 0.189 3.191

0.193 0.204

“0% 0.242

0.194 0,195 0.196 0.197 0,206 0.207 0.208 0.209 0.218 0.219 0.220 0.221 0.230 0.232 0.233 0.234 0.244 0.245 0.247 0.248

0.199 0.200 0.201 0.210 0.212 0.213 0.223 0.224 0.225 0.236 0.237 0.238 0.249 0.251 0.252

0.202 0,214 D.227 0.24a 0.254

0.256 0.258 0.259 0.261 0.262 0.263 0.265 0.26t 0.268 0.271 0.272 0.274 0.275 0.277 0.278 0,280 0.281 0.283 0.286 0.287 0.289 0.290 0.292 0.293 0.295 0.29; 0.298 0.301 0.303 0.304 0.306 0.308 0,309 0.311 0.311 0.314 0.317 0.319 0.321 0.322 0.324 0.326 0.327 0.325 0.331

0.334 0.336 0.337 0.339 0.341 0.342 0.344 0.34t 0.34f 0.351 0.353 0.354 0.356 0.358 0.360 0.362 0.36: 0.365 0.369 0.370 0.372 0.374 0.376 0.378 0.379 0.381 0.382 0.387 0.389 0.390 0.392 0.394 0.396 0.398 0.40( 0.401 0.405 0.407 o-409 0.411 0.413 0.415 0.417 0.41: 0.421

0.424 0.426 0.428 0.430 0.432 0.434 0,436 0.43t 0.44( 0.444 0.446 0.448 0.450 0,452 0.454 0,456 0,45t o&.x 0.464 0.466 0.468 0.470 0.472 0.474 0.476 0.47[ 0.48( 0.484 0.487 0.489 0.491 0.493 0.495 0.497 0.495 0,501 0.505 0.508 0.510 0.512 0.514 0.516 0.518 0.52( 0.52:

-

7 I(

I

~EMPE- !ATURE

GER tot

_-

1.103 5

j.103 I.105 ). 107 I.110 ). 114

I.118 I.124 I.130 I.137 I.144

::

1’: 15

I.152 16 I.161 17 I.171 18 I.181 19 3.192 20

3.203 3.215 3.228 3.241 0,255

2’: 23 24 25

0.269 0.284 0.3oa 0.316 0.332

26 27 28 29 30

I

z; 33 34 35

0.442 0.462 0.48; 0.502 0.52:

36 37 38 39 40

-

Page 75: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/70 NOMINAL CAPACITY 70 cm8

(Coefficient of cubical thermal expansion of glass 30 x 10-‘L/OC) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/70). -

--

a

E C C (

(

I I 1 I I ( (

( t t I

I

,

/

-

-

-- -- -- --

I.120 ‘.120 I.120 I.120 C I.120 3.120 3.120 I.120

I.120 I.121 I.123 b.126 j.129

I.120 I.120 1.121 1.121 I. 123 I.123 1.126 1.126 I.130 3.130

I.120 I.121 I.124 I.127 I.131

).I20 I.122 I.124 I.127 I.131

0.121 0.122 0.124 0.127 0.132

3.121 1.121 3.122 3.122 3.124 3.125 0.128 1.128 0.132 3.133

I.134 I.140 t.146 j.154 j.162

I.135 3.135 j.140 3.141 I.147 3.148 L154 3.155 I.163 0.164

I.136 1.142 I.148 3.156 3.164

I.136 I.142 I.149 I.157 1.165

0.137 0.143 0.150 0.158 0.166

0.137 0.144 0.151 0.158 0.167

3.138 0.144 0.151 0.159 0.168

I.171 I.181 I.191 I.203 I.215

I.172 0.173 I. 182 0.183 I. 192 0.193 I.204 0.205 I.216 0,217

3.174 0.184 0.195 0.206 0.219

3.175 3.185 3.196 3,207 0.220

0.176 0.177 o.i7a 0.186 0.187 0.18e 0.197 0.198 0.195 0.209 0.210 0,211 0.221 0.222 0.224

1,228 1,241 3.255 3,270 3.286

I.229 0.230 I.243 0.244 1.257 0.258 I.272 0.273 1.288 0.289

I I

1 I ; I

1 I

! I

I

; ,

i I

0.232 0.24: 0.26C 0.27: 0,291

0.233 0.247 0.261 0.277 0.293

0.234 0.236 0.23; 0.248 0.250 0.251 0.263 0,264 0.26t 0.278 0.280 0,281 0,294 0.296 0.29;

0.302 0.319 0.337 0.355 0,374

3.304 0.306 3.321 0.323 0.339 0.341 0.357 0.359 0.376 0.378

0.30; 0.325 0.34; 0.361 0.38(

1

i ,

i

0.30s 0.326 0.344 0.36: 0.382

0.311 0.328 0.346 0.36: 0.384

0.312 0.31’ 0.330 0.33: 0.348 0.35( 0.366 0.361 0.386 0.381

0.394 0.414 0.434 0.45: 0.47;

0,.50( 0.52: 0.54( 0.57( 0.59:

0,395 0.41E 0.43C 0.45E 0.47:

0.50: 0.52! 0.541 0.57: 0.59

0.397 0.418 0.438 0.46C 0.482

0,39! 0.42( 044 0.46: 0.48‘

0.401 0.42: 0.44: 0.46‘ 0.481

04QE 0,424 0.44: 0.46t 0.481

0.40: 0.40’ 0.42E 0.421 0.44; 0,441 0.46f 0.47 0.491 0.49

0.501 0.52: 0.55 0.57. 0.601

0.50’ 6 0.530 0.553 0.577 0.602 0.60

0.50’ 0.53 0.55 0.58

0.51 0.53, 0.55’ 0.58 0.60

0.51: 0.51 0.53’ 0.53 0.561 0.56 0.58 0.58

0.611 0.61

TEMPE-

RATURE

W:FER

tee

EYPE-

4TURE

VZER

tot

0.0

I.121

1.120 b.121 ).122 ). 125 I.129

I.133 I.139 I.145 I.152 I.160

I.169 I.179 I.189 I.200 1.212

1,225 3.238 3.253 3.267 0.283

0.299 0.316 0,333 0.351 0.37c

0.39c 0.41C 0.43( 0,451 0 47:

0.49i 0,511 0.54 0.56: 0.59(

0.1

5

11

::

:3

16 17 18

:I:

21

;z 24 25

26 27

2: 30

36 37 38

ii

I.121

I.120 j.121 I.123 b.125 ). 129

1.134 I.135 I. 146 ).15? I.161

I.17C I.18C I.19C I.201 1.21:

1.22f 3.24( 3.251 3.261 3.28‘

0.30 0.311 0.331 0.35: 0.37:

0.39: 0.41: 0.43 0.45 0.47

0.49 0.52 0.54 0.56 0.59

5

11

:; 14 15

:: 18

:8

:; 23 24

32 33 34 35

36 37 38

z

71

Page 76: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/75 NOMINAL CAPACITY 75 cm3

(Coefficient of cubical thermal expansion of glass 30 x 10-6/0C) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/75).

TEMPE.

RATURI

WZER

PC

5

::

:i 15

26 27

z: 30

36

ii 39 40

0-O 0.1

0.12s 0,129 0.129

0.125 0.125 0.131 0,134 0.13E

0.12s 0.13c 0.131 0.134 0.138

0.129 0.130 0.132 0.135 0.139

0.143 0.143 0.144 0.148 0.149 0.150 0.155 0.156 0.157 0.163 0.164 0.165 0.172 0.172 0.173

0.181 0.182 0.183 0.191 0.192 0.194 0.203 0.204 0.205 0.215 0.216 0.217 0.227 0,229 0.230

0.241 0.242 0.244 0.255 0.257 0.258 0.271 0.272 0.274 0,286 0.288 0.290 0.303 0.305 0.307

0.320 0.322 0.324 0.338 0.340 0.342 0.357 0.359 0.361 0,377 0.379 0.381 0.397 0.399 0.401

0.417 0.420 0.422 0.439 3.441 0,443 0.461 3.463 3.465 D.483 3.486 3.488 3.507 3.509 3.511

I.530 I.533 I.535 I.555 I.557 I.560 I.580 I.582 I.585 I.606 I.608 ,.Sil I.632 I.634 I.637

0.12!

0.12! 0.13( 0.13: 0.13: 0.135

0.14‘ 0.15( 0.15: 0.16: 0.17’

0.18L 0.19: 0.20( 0.21E 0,231

0.24: 0.26C 0.27: 0.291 0.30E

0.326 0.344 0.363 0.383 0.403

3.424 3.445 I.467 I.490 I.514

I.538 I.562 I.588 j.613 I.640

0.121

0.12! 0*13( 0.13: 0.13: 0.14(

0.14: 0.151 0.15E 0.16t 0.17:

0.18: 0.19t 0.20; 0.22C 0.232

0.24; 0.261 0.275 0.293 0.310

0.328 Cl.346 3.365 3.385 I.405

I.426 I.447 I.470 I.493 I.516

). 540 I.565 j.590 b.616 j.642

-

-_

I

i

1 i i

i

i 1

I 1

’ ,

,

I

; I

I I

( ( (

I (

: ( (

:

: C

-

0,125

0.12: 0.13( 0.13; 0.13( 0,14(

0.14: 0.15; 0,155 0.167 0.176

0.18E 0.197 0.208 0.221 0.234

0.248 0.263 0.278 D.295 D.312

1.329 3.348 3.367 I.387 I.407

I.428 I.450 I.472 I.495 I.518

b.543 j.567 I.593 I.619 I.645

-

--

0.9

0. l2S 0.125 0.12! 0.129

:: E 0,132 0.13E 0.141

;::;; 0.133 0.137 0.141

0*12! 0.13 0.13: 0.13: 0.14:

-

-.

/

, 0.129 0.131 0.134 0.137 0,142

0.14E 0.147 0.14: 0.148 0.152 0.153 0.15r 0.155 0.16C 0.161 0.16 0.162 0.168 0,169 0.17( 0.171 II.177 0.178 0.171 0.180

0,187 0.188 0.18: 0.190 0.198 0.199 0.20( 0,201 0,210 0.211 0.21: 0.213 0,222 0.223 0.22: 0.226 D.235 0~237 0.23E 0.240

3.250 0.251 0.25; 3.264 0.266 0.26; 3.280 0.282 0.28? I.296 0.298 0.3oc I.313 0.315 0.311

%Z 0.285 0.301 0.319

I.331 0.333 0.335 I.350 0.352 0.353 I.369 0.371 0.373 I.389 0.391 0.393 I.409 0,411 0.413

0.337 0.355 D.375 D.395 3.415

I.430 0.432 0.434 I.452 0.454 0.456 1,474 0,477 3.479 j.497 0.500 3.502 j.521 0.523 3.526

I.545 3,548 3.550 I.570 3.572 I.575 I.595 I.598 3.600 I.621 I.624 I.626 I.648 I.650 I.653

/

I

I

I

I

(

I

( ( ( (

(

I I

-

3.437 3,459 3.481 I.504 I.528

I.552 I.577 I.603 I.629 I.656

TMPE-

RATURE

GER

1°C

72

Page 77: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TEMPE

RATUR

v&I

t”C

5

:: 13 14 15

16 17

:"9 20

;: 23 24 25

31 32

ii 35

IS : 8897 - 1978

TABLE lDj80 NOMINAL CAPACITY 80 cd

(Coefficient of cubical thermal expansion of glass 30 x 10--B/OC) Add to mass (grams) of pure. water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table Z/80).

0.0

0.131

3.13’ 3.131 3.14( 3.14: 3.14:

3.15: 3.15[ 1.16f 3.171 1.18:

1.19: I.204 1.21t

E?S

I.255 I.272 j.289 I.306 I.323

I.342 1,361 I.381 I.402 I.423

I.445 I.468 1.491 1,516 I.540

,566

,619 .646 ,674

-

-.

3

0.1

0.131

0.13’ 0.13( 0.14( 0.14: 0.14:

0.15: 0.15: 0. I6( 0.17: 0.184

0.194 0.20: 0.21; 0.23C 0.244

0.259 0,274 0.29c 0.307 0.325

3.344 0.363 3.383 I.404 3.425

I.447 I.470 I.494 I.518 I.543

I.568 3,595 I.621 I.649 j.677

o-3

- -

0.2 o-4 O-5 O-6 o-7 O-8 @9

- -_

0,138 0.138 0,131 3 0.13; 7 0.13; 0.13; 0.137 0.137

0.137 0.137 0.13l 0.138 0.139 0.13s 0.140 0.141 0,141 0,144 0.144 0.141 0.148 0.148 0.14s

0.13t 0.13s 0.141 0.14: 0.145

0.131 0.13E 0.13& 0.138 0.135 0.135 0.13s 0.140 0.14; 0.142 0.142 0.143 0.14: 0.14t 0.146 0.147 0.15c 0.15c 0.151 0.152

0.153 0.154 0.160 0.160 0.167 0.168 0.176 0.176 0,185 0.186

o.lsz 0.16j 0.165 0.17; 0.187

i 0.15: i 0.15t 0.156 0,157 0.158 I 0.16; , 0.162 0.163 0.164 0.165 t 0.17C 1 0.17c 0‘171 O-172 0.173 f 0.17E I 1 0.179 0.180 0.181 0.182 ’ 0.181 I 1 0.189 0.190 0.191 0.192

0.19.5 0.196 0.197 0.206 0.208 0,209 0.219 0.220 0.221 0.232 0.233 0.234 0.245 0.247 0.248

0.198 D.210 0.222 0.236 0.250

’ /

I I

,

I

I I

I

1 I

I

I

(

(

(

t

(

(

I

(

(

:

(

:

-

0.2oa 0.201 0,202 0.203 3.211 0.212 0.214 0.215 3.224 0.225 0.226 0.228 3.237 0.238 0.240 0.241 0.251 0.253 0.254 0.256

0.260 0.262 D.263 0.276 0.277 D.279 0.292 0.294 0.295 0.309 0.31 I 0.313 0.327 D.329 3.331

3.265 3.280 3.297 3.314 3.332

3.266 0.268 0.269 0.271 3.282 0.284 0.285 0.287 3.299 0.300 0.302 0.304 3.316 0.318 0.320 0.321 1.334 0,336 0.338 0.340

0.346 0.347 3.349 0.365 D.367 3.369 0.385 D.387 3.389 3.406 3.408 I.410 1.427 I.430 I.432

I.351 3.371 I.391 I.412 I.434

I.353 0.355 0.357 0.359 I.373 0.375 0.377 0.379 I.393 0.395 0.398 0.400 I.414 0,417 0.419 0.421 I.436 0.439 0.441 0.443

I.450 3,452 I.473 1.475 I.496 I.499 I.521 I.523 I.545 I.548

I.454 I.477 I.501 I.525 I.551

I.457 I.480 I.503 I.528 I.553

I.459 0.461 0,463 0.466 I.482 0.484 0,487 0.489 I.506 0.508 0,511 0.513 I.530 0.533 0,535 0.538 I.556 0.558 0.561 0.563

I.571 I.574 I.576 I.597 I.600 I.603 1.624 1.627 I.629 I.651 I.654 I.657 I.680 I.682 j.685

I.579 j.605 X32 I.660 I.688

j.581 0.584 0.587 0.589 I.608 0.611 0.613 D.616 I.635 0.638 0.640 0,643 I.663 0.665 0.668 0.671 j.691 0.694 D.697 D.700

TEMPE-

RATURE

:: 20

;: 23 sa 25

26 27

:: 30

31 32

:9 35

38

:z

73

Page 78: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/90 NOMINAL CAPACITY 90 ems

(Coefficient of cubical thermal expansion of glass 30 x 10-s/“C) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/90).

TEMPE- RATURE

WZR t”C

5

6 7 8

It

11 12 13

if

16 17

:: 20

21

i: 24 25

P 31 32 33 34 35

36

ii 39 40

-

I

.-

0

ii

0

8

ii

:

c

:

I (

( ( f ( I

I

I

I

,

-

- - .-

0

- - .- - -

,155 0 ,155 , 0.155 I 0.155 ,155 ,155

.-

0, ,155 0 1.155

-

0. 155

-

0 8.155

.155

.155 ,157 8.161 1.165

.155

.155 ,158 ‘.161 I.166

.155 0 ,155 ,156 0 ,156 .158 0 ,158 ,162 0 ,162 .166 0 ,167

.155 ,156 ,159 ,162 .168

,155 ,156 ,159 .163 ,168

,155 ,156 ,159 ,163 ,169

1.155 0, ,155 I.157 0, ,157 k160 0 ,160 I.164 0 .164 1.169 0 ,170

I.155 I.157 I.160 I.165 I.171

I.171 1.178 1.186 I.196 j.206

1.172 0 1.172 I.179 0 1.180 I. 187 a I.188 I.196 C I.197 I.207 C I.208

I.173 1.180 1.189 I.199 I.209

,174 1.181 I.190 I.200 I.210

.175 1.182 1.191 I.201 I.211

.175 ( j.176

.183 ( I.184 I.192 ( I.193 I.202 ( I.203 1.213 ( I.214

,177 .185 ,194 ,204 8.215

1.217 C I.218 ( I.220 j.230 ( 1.231 ( 1.232 1.243 ( I.244 ( 1,246 I.257 ( j.259 ( I.261 1,273 ( I.274 ( 1.276

I.221 1.234 j.247 j.261 F27E

0

i

E :

I : I (

I ( ! (

I.222 I.235 ).24S I.264 1.27:

I.223 1.236 j.250 I.265 j.281

I.225 I.238 I.252 I.267 I.283

( I I

I 1 I

3.226 3.239 3.253 0.268 0.284

1 E c

1.227 I.240 I.255 I.270 l.28G

I.177 I.185

E 1.21:

).22{ 1.24: 1.25f

;:;;;

( ( ( (

, I

I.289 1,307 1.325 3.344 3.364

I.291 I.308 3.327 3,346 3.366

I.293 1,310 3.328 3,348 3.368

I.294 1.31: 1.33( 1.35( 3.37(

1.29t I.314 1.33: 1.35: 1.37:

I E I : 1 (

i (

! ( ! ( ! f

3 ( 5 ( 3 I 1 I

L ( i (

).29E 1.31: 1.334 I.354 I.374 1 (

1 ( 3 (

3 I

3 I

k29C j.317 I.336 ).35C ).37( I (

0.301 0.315 0.33E 0.35t 0.37E

C

! : I I

j.303 i I 0.30: ) 321 0.32: k34C I 0.34: ).36C 1 0.36: 1 38( 1 0.38:

3.385 3.406 D.429 0.452 0.476

D-387 D.408 0.431 0.454 0.47t

D.389 0.411 0.433 0,455 0.481

;:;;;

D.43i D.45! 0.48:

1.39: 3.41: 3.431 D.46 D.48(

3.39: 3.41: 3,44( D.46‘ 0,481

i f 7 ( 1 ( 1 (

3 I

1.39; 3.42( 3.44: X46( 0.49

0.40( 1 ( 1.40: 0.42: ! ( 1.42’ 0.441 i ( 1.44: 0.46! 3 I 1.47: 0.49: 3 ( 3.496

0.40 0.42 0.45 0.47 0.49

0.501 0.52; 0.551 0.58( 0.6Of

0.502 0.525 0.55f 0.58: 0.611

0.50t 0.53; 0.55[ 0,58( 0.611

i ,

I 5 c

0,501 0.53, 0.56 0.58, 0.61

0.51 0.53 0.56, 0.59 0.61

0.51, 0.541 0.561 0.59, 0.62

0.511 0.54: 0.56! 0.59 0.62

0.51! 0.54. 0.57: 0.601 0.621

0.52 0.541 0.57. 0.60: 0.63

0.52 0.55 0.57 0.60 0.63

0.63; 0.66( 0.69( 0.72: 0.75[

EZ ! 0.69! 0.73( 0.76

:

: I

-

0.64: 0.67: 0.70: 0.73: 0.76<

4

El 6

5

zJ

0.64 0.67 0.70 0.736 0.768

0.64 0.67 0.70 0.73 0.77

0.65 0.68 0.71 0.74 0.77

J 3 i 1

s 2

; 5

: 4 5 7

-

0.65 0.68 0.71 0.74 0.77

0.65 0.68 0.71 0.74 0.78

0.661 0.691 0.72 0.75 0.78

: 5 2 1

0

:

z

-

0.6E 0.65 0.72 0.7: 0.7f

-

-

-

-

-

-

-

-

T1 RP

M

.-

‘$ 7 15 ;4

i3 )3 !4 i5 17

-

5

6 7 8

1:

11

:: 14 15

16 17

:: 20

21 22

;: 25

26 27 28

it

74

Page 79: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TABLE lD/lOO NOMINAL CAPACITY 100 cm3

(Coefficient of cubical thermal expansion of glass 30 x lo*/%) .4dd to mass (grams) of pure water at t”C to obtain capacity of vessel at 27%

(in conjunction with Table 2/100). -

0’0 0’1 0.2

.- ,-

1.172 0 1.172 0 ‘.172

1.172 I.173 I.175 I.179 k184

1.172 I.173 I.175 I.179 I.184

1.172 I.173 1.176 I.180 I.185

). 190 ). 198 I.207 j.217 I.229

I.191 ). 199 I.208 i.218 j.230

). 192 I.200 I.209 j.219 j.231

I.241 I.255 I.270 I.286 I.303

I.243 I.257 I.272 I.288 I.305

I.244 j.258 I.273 I.289 I.307

I.321 ( I.323 ( I.325 I.341 I I.343 ( I.345 I.361 I 3.363 I I.365 3.382 I 3.384 t 3.386 3.404 I 3.406 1 t 3.409

0.427 I 0.430 1 I 0.432 0.451 I 0.454 I 0.456 0.47e i 1 0,479 1 , 0.481 0.502 ’ , 0.505

; /

1 I 0.505 0.529 0.532 ! ( 0.534

0.55; 0.58: 0.614 0.64E 0.67f

1

t

i

j

0.555 0.58f 0.61; 0.64t 0.675

I

I

;

I

0.562 0,591 0.62C 0.651 0.682

0.70; 0.74( 0.77: 0.80; 0.84:

I 1 7 P

-

0.711 0.74: 0.77; 0.811 0.84(

0.711 0.74; 0.78( 0.81~ 0.84s

-

-

-

(

I I I I

I

I

I

I

/

,

,

,

I

,

c

I : -

- -

.- .-

I.172 ( I.172 c I.172

j.172 j.174 I.177 I.182 I.187

I.172 I.174 I.177 I.182 I.188

j.172 j.174 I.178 I.183 I.189

3.195 I.203 3.213 3.224 0.236

I.195 I.204 I.214 3.225 D.237

( ( I

I.196 I.205 I.215 3.226 3.239 I

0.250 0.264 0.28C 0.29t 0.314

0.251 I D.252 0.266 i , 0.267 0.281 , 0.283 0,298 I 1 0.3oc 0.31E i 0.31E

0.33E 0.35: 0.37f 0.39; 0,42(

0.337 0.357 0.37f 0,40( 0.42:

0.44: ) 0.44‘ 0.46t 5 0.46: 0.49: 7 0.49‘ 0,511 3 0.52. 0.54! 5 0.541

0.44f 0.47 1 0.49: 0.52: 0.55:

0.57’ 0.60: 0.63: 0.661 0 69.

:

: 5

;

: 4

-

0.57( i O-57! 0.601 5 0.601 0.631 5 0.631 0.661 5 0.66! 0.691 s 0.70

0.72 0.761 0.79, 0.82’ 0.86,

0.731 0.76. 0.79 0.83: 0.86

;

: 7

-

0.73: 0.76’ 0.80 0.83. 0.87

TEMPE-

RATURE

W%R

f”C

‘EMPE-

4TURE

&R

toe

0.3 0’4

--

I.172 0 ,172

I.172 I.173 I.176 I.180 3.186

.172

.173 1.176 1.181 I.186

3.192 3.201 0.210 0.221 0.232

I.193 I.201 I.211 I.222 I.234

0.245

;:;; o-29; 0,305

j.24; j.261 ).27t j.292 ).31C

0.32; 0.34; 0.36; 0.38: 0,411

1 ( 7 (

I I

L (

&32I I.345 I.365 I.391 1.411

0.43‘ 0.45s 0.48‘ 0.51( 0.53’

& I

3 I

7 1

1.43;

;::;I 0.51: 0.541

0.56. 0.59, 0.62. 0.65, 0.68

/

:

3 4 5

0.561 0.59’ 0.621 0.65 0 681

0.71 0.75 0.78 0.81 0.85

0.721 0.75 0.78 0.82 0.85

--

0

i C

:

C (

: (

( (

I (

( I I I t

I I I ,

-

.172

.172

.174 I.177 1.181 19 187

I.194 I.202 I.212 b.223 j.235

3.24P j.262 ).27E 1.295 1.31;

I.331 I.351 I.371 1.39: 1.41f

1.43s 1.46< 3.48! D.511 D.54:

0.57 0.60( 0.62! 0,661 0.69

0.72, 0.751 0.791 0.82 0.86

I.172

I.172 j.175 I.178 I.183 I.189

I.197 I.206 3.216 3,228 3.240

0.254 0.269 0.284 0.301 0.32C

0.335 0.355 0.38C 0.40; 0.42:

0.44s 0.47’ 0.50( 0.52f 0.552

0.58: 0.61 0.64 0.67: 0.70‘

0.73’ 0.77( 0.80~ 0.83! 0.87,

f 8

1:

11 12 13 14 15

:; 18

:t

26 27 28 29 30

31 32 33

z:

36

E 39 40

Page 80: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/200 NOMINAL CAPACITY 200 ems

(Coefficient of cubical thermal expansion of glass 30 x lO+/‘C) :apacity of vessel at 27°C Add to mass (grams) of pure water at t”C to obtain c

(in conjunction with Table 2/2( )O)

O-7

TEMPE- RATURE

WZER tot

0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0 34

0.34 0.35

z; 0:3;

0.38 0.40 0.41 0.43 0.46

0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.34 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.36 0.36 0.36 0.36 0.36 0.36 0.36 0.36 0.36 0.37 0.37 0.37 0.37 0.37 0.37 0 37 0.37 0.38 0.38 0.38

0.38 0.38 0.38 0.39 0.39 0.39 0.39 0.39 0.39 0.40 0.40 0.40 0.40 0.40 0.41 0.41 0.41 0.41 0.42 0.42 0.42 0.42 0.42 0.43 0.43 0.43 0.43 0.44 0.44 0.44 0.44 0.45 0.45 0.45 0.45 0.46 0.46 0.46 0.46 0.47 0.47 0.47 0.47 0.48 0.48

0.48 0.49 0.49 0.49 0.49 0.50 0.50 0.50 0.50 0.51 0.51 0.51 0.52 0.52 0.52 0.52 0.53 0.53 0.53 0.54 0.54 0.54 0.55 0.55 0.55 0.56 0.56 0.56 0.57 0.57 0.57 0.58 0.58 0.58 0.59 0.59 0.59 0.60 0.60 0.60 0.61 0.61 0.61 0.62 0.62 0.62 0.63 0.63 0.64 0.64

0.64 0.65 0.65 0.65 0.66 0.66 0.67 0.67 0.67 0.68 0.68 0.69 0.69 0.69 0.70 0.70 0.71 0.71 0.71 o-72 0.72 0.73 0.73 0.73 0.74 0.74 0.75 0.75 0.76 0.76 0.76 0.77 0.77 0.78 0.78 0.79 0.79 0.79 0.80 0.80 0.81 0.81 0.82 0.82 0.83 0.83 0.84 0.84 0.85 0.85

0.85 0.86 O-86 0.87 0.87 0.88 0.88 0.89 0.89 0.90 0.90 0,91 0.91 0.92 0.92 0.93 0.93 0.94 0.94 0.95 0.95 0.96 0.96 0.97 0.97 0.98 0.98 0.99 0.99 1.00 1.00 1.01 1.01 1.02 1.03 1.03 1.04 1.04 1.05 1.05 1.06 1.06 1.07 1.07 1.08 1.09 1.09 1.10 1.10 1.11

1.11 1.12 1.12 1.13 1.14 1.14 1.15 1.15 1.16 1.16 1.17 1.18 1.18 1.19 I.19 1.20 1.21 I.21 1.22 1.22 1.23 1.23 1.24 1.25 1.25 1.26 1.26 1.27 1.28 1.28 1.29 1.30 1.30 1.31 1.31 1.32 1.33 1.33 1.34 1.34 1.35 1.36 1.36 1.37 1.38 1.38 1.39 1.40 1.40 1.41

1.41 1.42 1.43 1.48 1.49 l-49 1.55 1.55 1.56 1.61 1.62 1.63 1.68 1.69 l-70

1.43 1.50 1.57

1.44 l-45 1.45 1.46 1.47 1.47 1.51 1.51 1.52 I..53 1.53 1.54 1.57 1.58 1.59 1.59 1.60 1.61 1.64 1.65 1.66 1.66 1.67 1.68 1.71 1.72 1.73 1.73 1.74 1.75

O-8 o-9

~EMPE- 2ATUP.E

OF WATER

t”C

5

11

:s 14 15

16 17

:x 20

26 27 28

z:

ii 33 34 35

36 37

ii 40

76

Page 81: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TEYPE- RATURE

W%R

t”C

TABLE lD/250 NOMINAL CAPACITY 250 cm3

(Coefficient of cubical thermal expansion of glass 30 x 10-6/oC) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/250).

5

11

:: 14 15

16

:i 19 20

31

:: 34 35

36 37

98 40

0-O O-1 o-2 O-3 0’4 0.5 0.6 o-7 O-8 o-9

0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43

0.43 0.43

8:E 0.46

0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 o-44 0.44 0.44 0.114 0.44 0.44 0.44 0.44 0.44 0.44 0.44 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.46 0.46 0.46 0.46 0.46 0.46 0.47 0.47 0.47 0.47 0.47 0.47

0.48 0.48 0.48 0.48 0.48 0.48 0.49 0.49 0.49 0.49 0.49 0.50 0.50 0.50 0.50 0.51 o-51 0.51 0.51 0.52 0.52 0.52 0.52 0.52 0.53 0.53 0.53 0.54 0.54 0.54 0.54 0.55 0.55 0.55 0.55 0.56 0.56 0.56 0.57 0.57 0.57 0.57 0.58 0.58 0.58 0.59 0.59 0.59 0.60 0.60

0.60 0.61 0.61 0.61 0.62 0.62 0.62 0.63 0.63 0.63 0.64 0.64 0.65 0.65 0.65 0.66 0.66 0.66 0.67 0.67 0.68 0.68 0.68 0.69 0.69 0.69 0.70 0.70 0.71 0.71 0.72 0.72 0.72 0.73 0.73 0.74 0.74 0.74 0.75 0.75 0.76 0.76 0.77 0.77 0.78 0.78 0.78 0.79 0.79 0.80

0.80 0.81 0.81 0.82 0.82 0.83 0.83 0.84 0.84 0.85 0.85 0.86 0.86 0.87 0.87 0.88 0.88 0.89 0.89 0.90 0.90 0.91 0.91 0.92 0.92 0.93 0.93 0.94 0.94 0.95 0.95 0.96 0.97 0.97 0.98 0.98 0.99 0.99 1.00 1.00 1.01 1.02 1.02 1.03 1.03 1.04 1.04 1.05 I.06 1,OG

1.07 1.07 I.08 1.09 1.09 1.10 1.10 1.11 1.12 1.12 1.13 1.13 1.14 1.15 1.15 1.16 1.17 1.17 1.18 1.18 1.19 1.20 1.20 1.21 1.22 1.22 1.23 1.24 1.24 1.25 1.26 1.26 1.27 1.28 1.28 1.29 1.30 1.30 1.31 1.32 1.32 1.33 1.34 1.34 1.35 1.36 1.36 1.37 1.38 1.38

1.39 1.40 1.41 1.41 1.42 1.43 1.43 1.44 1.45 1.46 1.46 1.47 1.48 1.48 1.49 1.50 1.51 1.51 1.52 1.53 1.54 1.54 1.55 1.56 1.57 1.57 1.58 1.59 1.60 1.60 1.61 1.62 1.63 1.63 1.64 1.65 1.66 1.67 1.67 1.68 1.69 1.70 1.70 1.71 1.72 1.73 1.74 1.74 1.75 1.76

1.77 1.78 1.78 1.79 1.80 1.81 1.82 1.85 1.86 1.87 1.87 1.88 1.89 1.90 1.93 1.94 1.95 1.96 1:97 1.98 1.98 2.02 2.03 2.04 2.04 2.05 2.06 2.07 2.11 2.11 2.12 2.13 2.14 2.15 2.16

1.83 1.91 I.99

1.83 1.84 1.92 1.92 2.00 2.01 2.09 2.10 2.18 2.19

~EMPE-

L4TlJRE

Wzt

t”C

77

Page 82: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/500 NOMINAL CAPACITY 500 cd

(Coefficient of cubical thermal expansion of glass 30 x 1O-s/oC) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/500).

0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.86

0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.86 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.87 0.88 0.88 0.88 0.88 0.88 0.88 0.89 0.89 0.89 0.89 0.90 0.90 0.90 0.90 0.91 0.91 0.91 0.91 0.92 0.92 0.92 0.92 0.93 0.93 0.93 0.94 0.94 0.94 0.95

0.95 0.95 0.96 0.96 0.97 0.97 0.97 0.98 0.98 0.99 0.99 0.99 1.00 1.00 1.01 1.01 1.02 1.02 1.03 1.03 1.03 1.04 1.04 1.05 1.05 1.06 1.06 1.07 1.08 1.08 1.09 1.09 1.10 1.10 1.11 1.11 1.12 1.13 1.13 1.14 1.14 1.15 1.16 1.16 1.17 1.17 1.18 1.19 1.19 1.20

1.21 1.21 1.22 1.23 1.23 1.24 1.25 1.25 1.26 1.27 1.28 1.28 1.29 1.30 I.31 1.31 1.32 1.33 1.34 1.34 1.35 1.36 1.37 1.37 1.38 1.39 1.40 1.41 1.41 1.42 1.43 1.44 1.45 1.46 1.46 1.47 1.48 1.49 1.50 1.51 1.52 1.52 1.53 1.54 1.55 1.56 1.57 1.58 1.59 1.60

1.61 1.62 1.63 1.64 1.64 1.65 1.66 1.67 1.68 1.69 1.70 1.71 1.72 1.73 1.74 1.75 1.76 1.77 1.78 1.79 1.80 1.81 1.82 1.84 1.85 1.86 1.87 1.88 1.89 1.90 1.91 1.92 1.93 1.94 1.95 1.96 1.98 1.99 2.00 2.01 2.02 2.03 2.04 2.05 2.07 2.08 2.09 2.10 2.11 2.12

2.14 2.15 2.16 2.17 2.18 2.20 2.21 2.22 2.23 2.24 2.26 2.27 2.28 2.29 2.31 2.32 2.33 2.34 2.36 2.37 2.38 2.39 2-41 2.42 2.43 2.45 2.46 2.47 2.48 2.50 2.51 2.52 2.54 2.55 2.56 2.58 2.59 2.60 2.62 2.63 2.64 2.66 2.67 2.69 2.70 2.71 2.73 2.74 2.75 2.77

2.78 2.80 2.81 2.82 2.84 2.85 2.87 2.88 2.90 2.91 2.93 2.94 2.95 2.97 2.98 3.00 3.01 3.03 3.04 3.06 3.07 3.09 3.10 3.12 3.13 3.15 3.16 3.18 3.19 3.21 3.22 3.24 3.25 3.27 3.28 3.30 3.32 3.33 3.35 3.36 3.38 3.39 3.41 3.42 344 3.46 3.47 3.49 3.50 3.52

3.54 3.55 3.57 3.59 3.60 3.62 3.63 3.65 3.67 3.68 3.70 3.72 3.73 3.75 3.77 3.78 3.80 3.82 3.83 3.85 3.87 3.88 3.90 3.92 3-93 3.95 3.97 3.99 4.00 4.02 4.04 4.05 4.07 4.09 4.11 4.12 4.14 4.16 4.18 4.19 4.21 4.23 4.25 4.26 4.28 4.30 4.32 4.34 4.35 4.37

TEMPE-

RATURE

GER

t”C

78

Page 83: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/lOOO NOMINAL CAPACITY 1000 cm3

(Coefficient of cubical thermal expansion of glass 30 x 10-s/‘%) Add to mass (grams) of pure water at t°C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/ 1 000).

TEMPE-

RATURE

WZR

t°C

-

8-O 0’1 o-2 o-3 o-4 o-5 O-6 o-7 @8 8-9

1.72 1.72 1.72 1.72 1.72 1.72 1.72 1.72 1.72 1.72

1.72 1.72 1.72 1.72 1.72 1.72 1.72 1.72 1.72 1.72 1.73 1.73 1.73 1.73 1.73 1.74 1.74 1.74 1.74 1.75 1.75 1.75 1.76 1.76 1.76 1.77 1.77 1.77 1.78 1.78 1.79 1.79 1.80 1.80 1.81 1.81 1.82 1.82 1.83 1.83 1.84 1.84 1.85 1.86 1.86 1.87 1.87 1.88 1.89 1.89

1.90 1.91 1.92 1.92 1.93 1.94 1.95 1.95 1.96 1.97 1.98 1.99 2.00 2.01 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 2.21 2.22 2.23 2.24 2.25 2.26 2.28 2.29 2.30 2.31 2.32 2.34 2.35 2.36 2.37 2.39 240

2.41 2.43 2.44 2.45 2.47 2.48 2.50 2.51 2.52 2.54 2.55 2.57 2.58 2.60 2.61 2.62 2.64 2.66 2.67 2.69 2.70 2.72 2.73 2.75 2.76 2.78 2.80 2.81 2.83 2.84 2.86 2.88 2.89 2.91 2.93 2.95 2.96 2.98 3.00 3.01 3.03 3.05 3.07 3.09 3.10 3.12 3.14 3.16 3.18 3.20

3.21 3.23 3.25 3.27 3.29 3.31 3.33 3.35 3.37 3.39 3.41 3.43 3.45 3.47 3.49 3.51 3.53 3.55 3.57 3.59 3.61 3.63 3.65 3.67 3.69 3.71 3.73 3.76 3.78 3.80 3.82 3.84 3.86 3.89 3.91 3.93 3.95 3.97 4.00 4.02 4.04 4.06 4.09 4.11 4.13 4.16 4.18 4.20 4.23 4.25

4.27 4.30 4.32 4.34 4.37 4.39 4.42 4.44 4.46 4.49 4.51 4.54 4.56 4.59 4.61 4.64 4.66 4.69 4.71 4.74 4.76 4.79 4.81 4.84 4.87 4.89 4.92 4.94 4.97 5.00 5.02 5.05 5.07 5.10 5.13 5.15 5.18 5.21 5.23 5.26 5.29 5.32 5.34 5.37 5.40 5.43 5.45 5.48 5.51 5.54

5.57 5.59 5.62 5.65 5.68 5.71 5.74 5.76 5.79 5.82 5.85 5.88 5.91 5.94 5.97 6.00 6.03 6.05 6.08 6.11 6.14 6.17 6.20 6.23 6.26 6.29 6.32 6.35 6.38 6.41 6.45 6.48 6.51 6.54 6.57 6.60 6.63 6.66 6.69 6.72 6.76 6.79 6.82 6.85 6.88 6.91 6.95 6.98 7.01 7.04

7.07 7.11 7.14 7.17 7.20 7.24 7.27 7.30 7.33 7.37 7.40 7.43 7.47 7.50 7.53 7.56 7.60 7.63 7.67 7.70 7.73 7.77 7.80 7.83 7.87 7.90 7.94 7.97 8.01 8.04 8.07 8.11 8.14 8.18 8.21 8.25 8.28 8.32 8.35 8.39 8.42 8.46 8.49 8.53 8.57 8.60 8.64 8.67 8.71 8.74

~EMPE-

tATURIS

WZR tot

5

::

:: 15

Zf 28 29 30

36 37

E 40

79

Page 84: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TEMPE. RATURI

OF WATER

t”C

5

f :

:: 15

16

:8’

:f

21 22

z: 25

26 27 28

ft

31 32 33 34 35

:; 38

:z

TABLE lD/l500 NOMINAL CAPACITY 1500 cm3

(Coefficient of cubical thermal exuansion of alass 30 x 10-8/oC) Add t& mass (grams) of1 xu~ water at tad to obtain &pacity of vesskl ai 27%

(in conjunction with Table 2/ 1 500).

0.0

2.5!

2.51 2.51 2.6: 2.61 2.71

2.8! 2.9: 3.1( 3.2f 3.4:

3.6: 3.8: 4.01 4.2’ 4.51

4.8; 5.11 5.41 5.72 F.Ot

6.41 6.77 7.14 7.53 7.93

E% 9.22 9.67 0.13

0.61 I.10 1.60 2.11 2.63

o-1

2.51 2.51

2.51 2.5! 2.6: 2.6: 2.7t

2.51 2.5s 2.6: 2.6! 2.7:

2.8f 2.8; 2.9t 2.9: 3.1: 3.11 3.2; 3.25 3.4: 3.4;

3.6‘ 3.8: 4.0; 4.3; 4.5;

3.6( 3.8; 4.1c 4.34 4.6C

4.8: 5.14 5.44 5.7t 6.lC

4.8E 5.1; 5.47 5.7s 6.13

6.44 6.48 6.81 6.84 7.18 7.22 7.57 7.61 7.97 8.02

8.39 8.43 8.82 8.86 9.26 9.30 9.71 9.76 0.18 0.23

0.66 0.71 1.15 1.20 1.65 I.70 2.16 2.22 2.69 2.74

0.2 I ‘!

-- 3

3

: 3 7

I I ) 7

i i

t )

I /

0.3

-

2.51

2.51 Z-6( 2.6‘ 2.7( 2.7{

3.6E 3.85 4.12 4.37 4.62

4.91 5.2C 5.51 5.83 6.16

6.52 6.88 7.26 7.65 8.06

8.47 8.91 9.35 9.81 0.27

0.76 1.25 1.75 2.27 2.79

-_

3

:

: 3

3 I i

#

1 ) ,

I

1

1

1

: 1 1

0.4

2.3

2.5[ 2.6(

2:;; 2.7:

-_

3

:

: 3

1 , i 1 )

1 , , I ,

, ,

2.5t

2.5t 2.6( 2.6: 2.7: 2.8(

2,9( <

;:y; 3.3: 3.5c

--

3

3 1 i

i

i

1 1

I

2.51

2.5[ 2.61 2.6: 2.7: 2.81

2.91 3.0: 3.lE 3.34 3.52

2.9: 3.0: 3.15 3.3t 3.54

3.7c 3.91 4.15 4.35 4.6E

3.72 3.94 4.li 4.42 4.68

3.74 3.96 4.19 4.44 4.71

4.93 5.23 5.54 5.86 6.20

, 4.96 5.26 5.57 5.89 6.23

4.99 5.29 5.60 5.93 6.27

6.55 6.59 F.62 6.92 6.95 699 7.30 7.34 7.38 7.69 7.73 7.77 8.10 8.14 8.18

8.52 8.95 9.39 9.85 0.32

8.56 8.99 9.44 9.90 0.37

8.60 9.04 9.49 9.95 0.42

0.80 1.30 I.80 2.32 2.85

1

:

: 1

-

0.85 1.35 1.85 2.37 2.90

0.90

::z 2.42 2.95

-

0.5

-

-

2.5t 2.5E

2.5[ 2.5E 2.61 2.61 2.6( 2.65 2.72 2.74 2.82 2.83

2.92 2.94 3.0E 3.08 3.21 3.23 3.38 3.39 3.56 3.58

3.76 3.78 3.98 4.01 4.22 4.24 4.47 4.50 4.74 4.76

5.02 5.32 5.63 5.96 6.30

5.05 5.35 5.66 5.99 6.34

666 6.70 7.03 7.07 7.41 7.45 7.81 7.85 8,22 8.26

8.65 9-08 9.53 9.99 0.47

8.69 9.13 9.58 0.04 0.51

0.95 I.00 1.45 I.50 1.96 2.01 2.48 2.53 3.01 3.06

2.5E

2.5s 2.61 2.65 2.75 2.84

2.96 3.09 3.24 3.41 3.60

3.81 4.03 4.27 4.52 4.79

5.08 5.38 5.70 6.03 6.37

6.73 7.11 7.49 7.89 8.31

8.73 9.17 9.62 0.09 0.56

1.05 1.55 2.06 2.58 3.12

TEMPE- RATURE

WZR tot

5

6

3

1:

:: 13 14 15

:; 18 19 20

f f 28

32:

Page 85: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE lD/2 000 NOMINAL CAPACITY 2 000 cm3

(Coefficient of cubical thermal expansion of glass 30x lO-s/oC) Add to mass (grams) of pure water at t”C to obtain capacity of vessel at 27°C

(in conjunction with Table 2/2 000).

TEMPE- RATURE

WSIPTER t”C

0-O

3.45 3.44 3.44 3.44 3.44 3.44 3.44 3.44 3.43 3.43

3.43 3.43 3.44 3.44 3.44 3.44 3.44 3.44 3.45 3.45 3.45 3.46 3.46 3.46 3.47 3.47 3.48 3.48 3.49 3.49 3.50 3.50 3.51 3.52 3.52 3.53 3.54 3.55 3.56 3.56 3.57 3.58 3.59 3.60 3.61 3.62 3.63 3.64 3.65 3.66 3.67 3.69 3.70 3.71 3.72 3.74 3.75 3.76 3.78 3.79

3.80 3.82 3.83 3.85 3.86 3.88 3.89 3.91 3.93 3.94 3.96 3.98 3.99 4.01 4.03 4.05 4.06 4.08 ‘4.10 4.12 4.14 4.16 4.18 4.20 4.22 4.24 4.26 4.28 4.30 4.32 4.34 4.37 4.39 4.41 4.43 4.46 4.48 4.50 4.53 4.55 4.57 4.60 4.62 4.65 4.67 4.70 4.72 4.75 4.77 4.80

4.83 4.85 4.88 4.91 4.93 4.96 4.99 5.02 5.05 5.07 5.10 5.13 5.16 5.19 5.22 5.25 5.28 5.31 5.34 5.37 5.40 5.43 5.46 5.50 5.53 5.56 5.59 5.62 5.66 5.69 5.72 5.76 5.79 5.82 5.86 5.89 5.93 5.96 5.99 6.03 6.06 6.10 6.14 6.17 6.21 6.24 6.28 6.32 6.35 6.39

6.43 6.47 6.50 6.54 6.58 6.62 6.66 6.69 6.73 6.77 6.81 6.85 6.89 6.93 6.97 7.01 7.05 7.09 7.13 7.17 7.22 7.26 7.30 7.34 7.38 7.42 7.47 7.51 7.55 7.60 7.64 7.68 7.73 7.77 7.81 7.86 7.90 7.95 7.99 8.04 8.08 8.13 8.17 8.22 8.27 8.31 8-36 8.40 8.45 8.50

8.54 8.59 8.64 8.69 8.74 8.78 8.83 8.88 8.93 8.98 9.03 9.08 9.12 9.17 9.22 9.27 9.32 9.37 9.42 9.47 9.53 9.58 9.63 9.68 9.73 9.78 9.83 9.89 9.94 9.99

10.04 10.10 10.15 10.20 IO.25 10.31 10.36 10.42 IO.47 IO.52 10.58 10.63 IO.69 10.74 10.80 10.85 10.91 10.96 11.02 Il.07

11.13 11.19 11.24 Il.30 11.36 11.41 11.47 11.53 Il.59 Il.64 11.70 11.76 11.82 11.87 11.93 11.99 12.05 12.11 12.17 12.23 12.29 12.35 12.41 12.47 12.53 12.59 12.65 12.71 12.77 12.83 12.89 12.95 13.01 13.07 13.14 13.20 13.26 13.32 13.39 13.45 13.51 13.57 13.64 13.70 13.76 13.83 13.89 13.95 14.02 (4.08

14.15 14.21 14.28 14.34 14.41 14.47 14.54 14.60 14.67 14.73 14.80 14.86 14.93 15.00 15.06 15.13 15.20 15.26 15.33 15.40 15.47 15.53 15.60 15.67 15.74 15.81 15.87 15.94 16.01 16.08 16.15 16.22 16.29 16.36 16.43 16.5C 16.57 16.64 16.71 16.78 16.85 16.92 16.99 17.06 17.13 17.2C 17.27 17.34 17.42 17.49

0.1 0.2 o-3 o-4 o-5 o-7 O-8 o-9

I~MPE- z%TURE

w:Ll t-2

5

:: 13 14 15

16 17

:t 20

81

Page 86: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 3A FACTOR TO CONVERT MASS (GRAMS) OF

(Coefficient of cubical thermal

0-O

0.073 635 O-073636 0.073 637 0.073 639 0.073 640

0.073 648 0.073 649 0.073 650 0.073 651 0.073 660 0.073 661 0.073 663 0.073 664 0.073 673 O-073 674 0.073 675 0.073 677 0.073 685 0.073 687 0.073 688 0.073 689 0.073 698 0.073 699 0.073 701 0.073 702

0,073 653 0.073 665 0.073 678 0.073 690 0.073 703

0.073 711 O-073 712 0.073 723 0.073 725 0.073 736 0.073 737 0.073 749 0.073 750 0.073 761 0.073 762

0.073 713

8% ‘7:: 0.073 751 0.073 764

0.073 714 0.073 716 0.073 727 0.073 728 0.073 740 0.073 741 0.073 752 0.073 754 0,073 765 0,073 766

0.073 774 0.073 775 0.073786 0.073 788 0.073 799 o-073800 0,073 812 0.073813 0.073824 0.073826

0,073 776

8:G ;:; 0.073 814 0,073 827

0.073 778 0.073 779 0.073 790 0.073 791 0.073 803 0.073 804 0.073 815 0,073 817 0,073 828 0.073 829

0.073837 0.073838 O-073 839 0.073 841 0.073 850 0.073 851 0.073 852 0.073 853 0.073 862 0.073 863 0.073 865 0.073 866 0.073875 0.073 876 0.073 877 0.073 879 0.073 888 0.073 889 0.073 890 0.073 891

8% % 0:073 867 0.073 880 0.073 893

0*073900 0.073901 0.073 903 0.073 904 ,0.073913 0.073914 0.073 915 0.073 917 0.073925 0.073 927 0.073 928 0.073 929 0.073 938 0.073 939 0.073 941 0.073 942 o-073951 0.073952 0.073 953 0.073 954

0.073 905 0.073 918

:.::z ;:; 01073 956

0.073963 0.073965 0.073 966 0.073 967 0,073 968 0.073 976 0.073 977 0.073 979 0.073 980 0.073 981 0.073 989 0.073990 0.073 991 0.073 992 0.073 994 0~074001 0.074003 0.074 004 0.074 005 0.074 006 0.074014 0.074015 0.074 016 0.074 018 0.074 019

0.074027 0.074028 0.074 029 0.074 030 0.074 032 0.074039 0.074041 0.074 042 0.074 043 0.074 044 0.074052 0.074053 0.074 054 0.074 056 0.074 057 0.074065 0.074066 0.074 067 0.074 068 0.074 070 0.074077 0.074078 0.074 080 0.074 081 0.074 082

O-1 0.2 o-3 o-4

82

Page 87: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

MERCURY AT t"C TO CAPACITY (cm") OF VESSEL AT 27°C

expansion of glass 10X 10-E/"C)

o-5 O-6 o-7 O-8 0.9 t”C

0.073 641 0.073643 0.073 644 0.073 645 0.073 646 5

0.073 654 0.073 655 0.073 656 0.073 658 0.073 659 0.073 666 0.073 668 0.073 669 0,073 670 0.073 672 0.073 679 0.073680 0.073 682 0.073 683 0.073 684 0.073 692 0,073 693 0.073 694 0.073 696 0.073 697 0.073 704 0.073 706 0.073 707 0.073 708 0.073 709

f

x 10

0.073 717 0.073718 0.073 720 0.073 721 0.073 722 0.073 730 0.073 731 0.073 732 0.073 733 0.073 735 0.073 742 0.073 743 0.073 745 0.073 746 0.073 747 0.073 755 0.073 756 0.073 757 0.073 759 0.073 760 0.073 767 0.073 769 0.073 770 0.073 771 0.073 773

::

:z 15

0.073 780 0.073 781 0.073 783 0.073 784 0.073 785 0.073 793 0.073 794 o-073 795 0.073 797 0.073 798 0.073 805 0.073 807 0.073 808 0.073 809 0.073 810 0.073 818 0.073 819 0.073 821 0.073822 0.073823 0.073 831 0.073832 0.073 833 0.073834 0.073836

if

:“9 20

0.073 843 0.073 845 0.073 846 0.073 847 0.073848 0.073 856 0.073 857 0.073858 0.073 860 0.073861 0.073 869 0.073 870 0.073 871 0.073872 0.073874 0.073881 0.073882 0.073 884 0.073 885 0.073886 0.073894 0.073 895 0.073 896 0.073898 0.073899

0.073 906 0.073 908 0.073 909 0.073 910 0.073912 0.073 919 0.073 920 0.073 922 0.073 923 0.073 924 0.073932 0.073 933 0.073934 0.073 936 0.073937 0.073944 0.073 946 0.073 947 0.073 948 0.073949 0.073 957 0.073 958 0.073 960 0.073 961 0.073962

26 27

zx 30

0.073 970 0.073982 0.073 995 0.074008 0.074020

0.073971

X:E :E 0.074009 0.074022

0.073972 0.073 973 0.073975 0.073985 0.073 986 0.073 987 0.073997 0.073999 0~074000 0~074010 0.074011 0.074013 0.074023 0.074024 0.074025

3:

;: 35

0.074033 0.074034 0.074035 0.074037 0.074038 0.074046 0.074047 0.074048 0.074049 0*074051 0.074058 0.074059 0.074061 0.074062 0.074063 0.074 071 0.074072 0.074073 0.074 075 0.074076 0.074 084 0.074085 0.074086 0.074 087 0,074089

83

Page 88: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

tot

5 0.073 643 0.073 644 0.073 645 0.073 647 0.073648

6 7 8

13

0.073 655 0.073 668 0.073 680 0.073 692 0.073 704

0.073657 0.073669 0.073 681 0.073 693 0.073 706

0.073 658 0.073 670 0,073682 0.073 695 0.073 707

0.073659 0.073660 0.073 671 0.073672 0.073 683 0.073685 0.073 696 0.073697 0.073 708 0.073709

::

:: 15

0.073 717 0.073718 0.073719 0.073 729 0.073 730 0.073 731 0.073 741 0.073 742 0.073 744 0.073 753 0.073 755 0.073 756 0.073 766 0,073 767 0.073 768

16 17

:x 20

0.073 778 0.073 790 0.073 802

0.073 720 0.073 733 0.073 745 0.073 757 0.073 769

0.073 721 0.073 734 0.073 746 0.073 758 0.073 771

0.073 815 0.073 827

0.073 839 0,073 851 0.073 864 0.073 876 0.073 888

0.073 779 0.073 791 0.073804 0.073 816 0.073828

0.073 780 0.073 793 0.073805 0.073817 0.073829

0.073 782 0.073 783 0.073 794 0.073 795 0.073 806 0.073 807 0.073 818 O-073 820

0.073 840 0.073 853 0.073 865 0.073877 0.073 889

0.073842 0.073854 0.073 866 0.073 878

0.073831 0.073832

0.073 843 0.073 844 0.073 855 0.073856 0.073867 0,073 869 0.073880 0.073 881 0.073 892 0.073893

0.073 901 0.073 913 ,0.073 925 0.073 937

0.073 902 n.n73 914

0.073891

0.073 950

_ _~ _~~ 0.073 926 0.073 939 0,073 951

0.073903 0.073 915 0.073 928 0,073 940 0.073 952

0,073 904 0.073 916 0.073 929 0.073 941 0.073953

0.073 905 0,073 918 0.073930 0.073 942 0.073955

31 0.073 962 0.073963 0.073964 32 0.073 974 0.073975 0.073 977 33 0,073 986 0.073 988 0.073 989 34 0,073 999 0~074000 0~074001 35 0.074 011 0.074012 0.074013

0.073966 0.073978 0.073 990 0.074002 0.074015

0.073967 0.073979 0.073991 0.074004 0.074016

36 0.074 023 0.074024 0.074026 37 0.074 036 0.074037 0.074038 38 0.074 048 0.074049 0.074050 39 0,074 060 0.074061 0.074063 40 0.074 072 0.074074 0.074075

0.074027 0.074039 0.074052 0.074064 0.074076

0.074028 0.074040 0.074053 0.074065 0.074077

0-O

TABLE3B FACTOR TO CONVERT MASS(GRAMS)OF

(Coefficient of cubical thermal

O-1 0.2 0'3 o-4

84

Page 89: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

MERCURY AT PC TO CAPACITY (cm3) OF VESSEL AT 27°C

expansion of glass 15 X 10--B/OC)

o-5 O-6 o-7 wa @9 #“C

0.073 649 0.073 650 0.073 652 0.073 653 0,073 654 5

0.073 661 0.073 663 0.073 664 0.073 66.5 0.073 666 0.073 674 0.073 675 0.073 676 0.073 677 0.073 679 0.073 686 0.073 687 0.073 688 0,073 690 0.073 691 0.073 698 0.073 699 0.073 701 0.073 702 0.073 703 0.073 7 10 0.073 712 0.073 713 0.073 714 0.073 715

0.073 7.23 0.073 735 0.073 747

“0% :z

“0:::; :z 0.073 748 0.073 761 0.073 773

0.073 725 0.073 726 0.073 728 0.073 737 0.073 739 0.073 740 0.073 750 0.073 751 0.073 752 0.073 762 0.073 763 0.073 764 0.073 774 0.073 775 0.073 777

11

:z 14 15

0.073 784 0,073 796

z:: ::; 0.073 833

0.073 785 0.073 786 0.073 788 0,073 789 0.073 797 0.073 799 0,073 800 0.073 801 0.073 810 0.073 811 0.073 812 0.073 813 0,073 822 0,073 823 0.073 824 0.073 826 0.073 834 0.073 835 0.073 837 0,073 838

16 17

:89 20

0.073 845 0.073 858 0.073 870 0.073 882 0.073 894

0.073 847

% ::: 0.073 883 0,073 896

0.073 848 0.073 849 0.073 850 0.073 860 0.073 861 0,073 862 0.073 872 0.073 874 0,073 875 0.073 885 0,073 886 0.073 887 0.073 897 0.073 898 0.073 899

;: 23 24 25

%Z z:: 0.073 931 0.073 943 0.073 956

0.073 908 0.073 909 0.073 910 0.073 912 0.073 920 0.073 92 1 0.073 923 0.073 924 0.073.932 0.073 934 0.073 935 0.073 936 0.073 945 0.073 946 0.073 947 0.073 948 0.073 957 0.073 958 0.073 959 0.073 961

0.073 968 0.073 969 0.073 970 0,073 972 0.073 973 0.073 980 0.073 982 0.073 983 0.073 984 0.073 985 0.073 993 0.073 994 0.073 995 0,073 996 0.073 997 0.074 005 0.074 006 0.074 007 0.074 009 0.074 010 0.074 017 0.074 018 0.074 020 0.074 02 1 0.074 022

z2 33 34 35

0.074 029 0.074 031 0.074 032 0.074 033 0,074 034 0.074 042 0.074 043 0.074 044 0.074 045 0.074 047 0.074 054 0.074 055 0.074 056 0.074 058 0.074 059 0.074 066 0.074 067 0.074 069 0.074 070 0,074 071 0.074 079 0.074 080 0.074 081 0.074 082 0.074 083

36

3: 39 40

--

85

Page 90: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 3C FACTOR TO CONVERT MASS (GRAMS) OF

(Coefficient of cubical thermal

0.0

0.073 659 0.073 660 0.073 662 0.073 663 0.073 664

0.073 671 0.073 672 0,073 673 0.073 674 0.073 675 0.073 682 0.073 683 0.073 685 0.073 686 0.073 687 0.073 694 0.073 695 0.073 696 0.073 697 0.073 698 0.073 705 0.073 706 0.073 708 0.073 709 0.073 710 0.073 717 0.073 718 0.073 719 0.073 720 0.073 721

0.073 728 0.073 730 0.073 731 0.073 732 0.073 733 0.073 740 0.073 741 0.073 742 0.073 743 0.073 744 0.073 751 0.073 753 0.073 754 0.073 755 0.073 756 0.073 763 0.073 764 0.073 765 0.073 766 0.073 768 0.073 774 0.073 776 0.073 777 0.073 778 0.073 779

0.073 786 0.073 787 0.073 788 0.073 789 0.073 791 0,073 797 0.073 799 0.073 800 0.073 801 0.073 802 0.073 809 0.073 810 0.073 811 0.073 812 0.073 814 0.073 821 0.073 822 0.073 823 0.073 824 0.073 825 0,073 832 0.073 833 0.073 834 0.073 836 0.073 837

0.073 844 0.073 845 0.073 846 0.073 847 0.073 855 0.073 856 0.073 857 0.073 859 0.073 867 0.073 868 0.073 869 0.073 870 0.073 878 0.073 879 0.073 880 0.073 882 0.073 890 0.073 891 0.073 892 0.073 893

0.073 848 0,073 860 0.073 871 0.073 883 0.073 894

0.073 901 0.073 902 0,073 904 0.073 905 0.073 906 0.073 913 0.073 914 0.073 915 0.073 916 0.073 917 0.073 924 0.073 925 0.073 927 0.073 928 0.073 929 0.073 936 0.073 937 0.073 938 0.073 939 0.073 940 0.073 947 0.073 949 0.073 950 0.073 951 0.073 952

0.073 959 0.073 960 0.073 961 0.073 962 0.073 964 0.073 970 0.073 972 0.073 973 0.073 974 0.073 975 0.073 982 0.073 983 0.073 984 0.073 985 0.073 987 0.073 994 0.073 995 0.073 996 0.073 997 0.073 998 0.074 005 0.074 006 0.074 007 0.074 009 0.074 010

0.074 017 0.074 018 0.074 019 0.074 020 0.074 028 0,074 029 0.074 030 0.074 032 0.074 040 0.074 041 0.074 042 0.074 043 0.074 051 0.074 052 0.074 054 0.074 055 0.074 063 0.074 064 0.074 065 0.074 066

0.074 021 0.074 033 0.074 044 0.074 056 0.074 067

O-1 0.2 o-3 o-4

86

Page 91: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

MERCURY AT PC TO CAPACITY (cm*) OF VESSEL AT 27°C

expansion of glass 25 x IO-S/%)

0.5 O-6 @7 o-8 o-9 PC

0.073665 0.073 666 0.073 667 0.073668 0.073 670 5

0.073 677 0.073 678 0.073679 0.073 680 0.073 681 0.073 688 0.073 689 0.073 690 0.073691 0.073 693 0.073 700 0.073 701 0.073 702 0.073 703 0.073 704 0.073 711 O-073 712 0.073 713 0.073 715 0.073 716 0.073 723 0.073 724 0.073 725 0.073 726 0.073 727

i

f 10

0.073 734 0.073 735 0.073 736 0.073 738 0.073 739 0.073 746 0,073 747 0.073 748 0.073749 0.073 750 0.073 757 0.073 758 0.073 759 0.073 761 0.073 762 0.073 769 0.073 770 o-073 771 0.073 772 0.073773 O-073 780 0.073 781 0.073 783 0.073 784 0.073 785

::

:: 15

0.073 792 0.073 793 0.073 794 0.073 795 0.073 796 0.073803 0.073804 0.073806 0.073807 0.073808 0.073815 0.073 816 0.073 817 0.073818 0.073 819 0.073 826 0.073827 O-073829 0.073 830 0.073 831 0.073 838 0.073839 0.073840 0.073841 0.073 842

if 18

:t

O-073849 0.073 851 0.073 852 0.073853 0.073854 0.073861 0.073 862 0.073863 0.073 864 0.073 866 0.073 872 0.073874 0.073875 0.073876 0.073 877 0.073884 0.073 885 0.073 886 0.073887 0.073889 0.073 895 O-073 897 0.073898 0.073899 0.073 900

o-073 907 O-073 908 0.073909 0*073910 0.073 912 0.073919 0.073920 0.073921 0.073 922 0.073 923 0.073930 0.073931 0.073 932 0.073 934 0.073 935 0.073942 0.073 943 0.073 944 0.073 945 0.073946 0.073953 0.073954 0.073955 0.073 957 0.073 958

26

ii 29 30

0.073965 0.073 966 0.073 967 0.073968 0.073 969 0.073976 0.073 977 0.073979 0.073980 0.073 981 0.073 988 0.073989 o-073990 0.073 991 0.073 992 0.073 999 0*074000 0.074002 0.074003 0.074004 0~074011 0.074012 0.074013 0.074014 0~074015

0.074022 0.074024 0.074025 0.074026 0.074034 0.074035 0.074036 0.074037 0.074045 0.074047 0.074048 0.074049 0.074057 0.074058 0.074059 0.074060 0.074069 0.074070 0.074071 0.074072

0.074027 0.074039

K% 8;; 0.074073

36

:i 39 40

87

Page 92: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 3D FACTOR TO CONVERT MASS(GRAMS)OF

(Coefficient of cubical thermal

O-0

0.073 667 0.073 668 0.073 670 0.073671 0.073672

0.073 678 0.073 680 0.073 681 0.073 682 0.073 683 0.073 690 0.073 691 0,073 692 0.073693 0.073 694 0.073 701 0.073 702 0.073 703 0.073 704 0.073 705 0,073 712 0073 713 0.073 714 0.073 715 0.073 716 0.073 723 0.073 724 0.073 725 0.073 726 0.073 728

0.073 734 0.073 735 0.073 736 0.073 738 0.073 739 0.073 745 0.073 747 0.073 748 0.073 749 0.073 750 0,073 757 0.073 758 0.073 759 0.073 760 0.073 761 0,073 768 0,073 769 0.073 770 0.073 771 0.073 772 0.073 779 0.073 780 0.073 781 0.073 782 0,073 783

0.073 790 0.073 791 0.073 792 0.073 793 0.073801 0.073 802 0.073803 0.073805 0.073 812 0.073 813 0.073 815 0.073816 0.073 823 0.073 825 0.073 826 0.073 827 0.073835 0,073 836 0.073837 0.073838

0.073 794 0.073806 0.073 817 0.073 828 0.073 839

0.073 846 0.073 847 0.073848 0.073849 0,073 857 0.073858 0.073859 0.073 860 0.073 868 0.073 869 0.073870 0.073 871 0.073 879 0.073 880 0.073882 0.073 883 0.073 890 0,073 892 0.073 893 0.073 894

0.073 850 0.073 861 0.073 873 0.073 884 0.073895

0.073 902 0.073 903 0.073 904 0.073 905 0.073 913 0.073 914 0.073 915 0.073 916 ,0,073 924 0.073 925 0.073 926 0,073 927 0.073 935 0,073 936 0.073 937 0.073938 0.073946 0.073947 0.073948 0.073 950

0.073906 0.073 917 0.073 928 0.073940 0.073951

0.073 957 0.073 959 0.073 969 0.073 970 0.073 980 0.073 981 0.073 991 0.073 992 0.074002 0.074 003

::::: SF? 0.073982 0.073 993 0.074004

0.073 961 0.073 962 0.073 972 0.073 973 0.073 983 0,073 984 0.073 994 0.073 995 0.074005 0.074007

0.074013 0.074 014 0.074024 0.074026 0.074036 0,074 037 0.074047 0.074 048 0.074 058 0.074059

Kz",:: 0.074038 0.074049 0.074 060

0.074017 0.074018 0.074028 0.074029 0.074039 0.074040 0.074 050 0.074051 0.074061 0.074062

O-1 0.2 o-3

-

Page 93: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

MERCURY AT t”C TO CAPACITY

expansion of glass 30 X 10--B/OC)

IS : 8897 - 1978

(cm") OF VESSEL AT 27°C

0.5 0'6 0.7 0.8 o-9 tot --

0.073673 0.073674 0.073 675 0.073 676 0.073 677 5

0.073 684 0.073 685 0,073 686 0.073 687 0.073689 0.073 695 0.073 696 0.073 697 0.073 699 0.073 700 0.073 706 0.073 707 0,073 709 0.073 710 0.073 711 0.073 718 0.073 719 0,073 720 0.073 721 0.073 722 0.073 729 0.073 730 0.073 731 0.073 732 0,073 733

6

x

It

0.073 740 cl.073 751 0.073 762 0.073 773 0.073 784

0.073 741 0.073 742 0.073 743 0,073 744 0.073 752 0.073 753 0,073 754 0.073 755 0.073 763 0.073 764 0.073 765 0.073 767 0.073 774 0.073 776 0.073 777 0,073 778 0.073 786 0.073 787 0.073 788 0,073 789

0.073 796 0.073 797 0.073 798 0.073 799 0.073800 0.073807 0.073 808 0.073809 0.073 810 0.073 at1 0.073818 0.073819 0.073 a20 0.073 a21 0.073822 0.073829 0.073830 0.073 831 0.073832 0.073834 0.073 840 0.073 a41 0.073 842 0,073 844 0.073 845

0.073 851 0.073863 0.073 a74 0.073 885 0.073 896

0.073907 0.073 908 0.073909 0,073 911 0,073 912 0.073 918 0.073919 0.073 921 0.073 922 0,073 923 0.073930 0.073931 0.073932 0,073 933 0.073 934 0.073941 0.073 942 0.073 943 0.073 944 0.073 945 0.073 952 0.073 953 0.073 954 0.073 955 0,073 956

0.073 963 0.073964 0.073965 0.073 966 0.073 967 0.073 974 0.073 975 0.073 976 0.073 978 0.073979 0.073985 0.073986 0.073 988 0.073 989 0.073990 0.073 997 0.073 998 0.073 999 0~074000 0~074001 0.074008 0.074009 0~074010 0~074011 0.074012

0.074019 0.074020 0.074021 0.074022 0.074023 0.074030 0.074 031 0.074032 0.074033 0.074034 0.074041 0.074 042 0.074043 0.074045 0.074046 0.074052 0.074053 0.074055 0.074056 0.074057 0.074064 0.074065 0.074066 0.074067 0.074068

0.073853 0.073854 0.073 855 0.073 856 0.073 864 0.073865 0.073866 0,073 867 0.073875 0.073876 0.073877 0.073878 0.073886 0.073887 0.073888 0.073889 0.073897 0.073 898 0,073 899 0.073901

11 12 13

if

16

:i

:t

ii 33 34 35

36 37

it 40

89

Page 94: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

IS : 8897 - 1978

TABLE 4A

MASS (GRAMS) ‘OF MERCURY CONTAINED OR DELIVERED AT t”C

BY A VESSEL OF CAPACITY 1 cma AT 27°C

(Coefficient of cubical thermal expansion of glass 10 x 10-E/oC)

TABLE ‘4B *

MASS (GRAMS) OF ;JvtERCURY CONTAINED OR DELIVERED AT t°C

BY A VESSEL OF CAPACITY 1 cm3 AT 27°C

(Coefficient of cubical thermal expansion of glass 15 X 10-B/oC)

13.580 13.579 5 13.579 13.578

13.578 13.577 13.576 13.575 13.573 13.572 13.571 13.570 13.569 13.568

f

! 10

13.577 13.576 13.574 13.573 13.572 13.571 13.570 13.569 13.568 13.567

13.566 13,565 13.564 13.563 13.562 13.561 13.559 13.558 13.557 13.556

:: 13

:‘5

13.565 13.564 13.563 13.562 13.561 13.560 13.559 13.557 13.556 13.555

13.555 13.554 13.553 13.551 13.550 13.549 13.548 13.547 13.546 13.544

16 17

:t 20

13.554 13.553 13.552 13.551 13.550 13.548 13.547 13.546 13.545 13.544

13.543 13.542 13.541 13.540 13.539 13.537 13.536 13.535 13.534 13.533

21 22 23

;s

13.543 13.542 13.541 13.539 13.538 13.537 13.536 13.535 13,534 13.533

13.532 13.531 13.529 13.528 13.527 13.526 13.525 13.524 13.522 13.521

13.532 13.530 13.529 13.528 13.527 13.526 13.525 13.524 13.523 13.522

13.520 13.519 13.518 13.517 13.515 13.514 13.513 13.512 13.511 13.510

13.520 13.519 13.518 13.517 13.516 13.515 13.514 13.513 13.511 13.510

13.509 13.507 13.506 13.505 13.504 13.503 13.502 13.500 13.499 13.498

13.509 13.508 13.507 13.506 13.505 13.504 13.502 13.501 13.500 13.499

o-5 tot 8-O 0.5

90

Page 95: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

TABLE 4C

MASS (GRAMS) OF MERCURY CONTAINED OR DELIVERED AT t”C

BY A VESSEL OF CAPACITY 1 cd AT 27°C

(Coefficient of cubical thermal expansion of glass 25 x 10-s/‘%)

IS : 8897 - 1978

TABLE 4D

MASS (GRAMS) OF MERCURY CONTAINED OR DELIVERED AT t”C

BY A VESSEL OF CAPACITY 1 cd AT 27°C

(Coefficient of cubical thermal expansion of glass 30 x 10-s/OC)

0-O

13.576 13.575

13.574 13.573 13.572 13.571 13.570 13.569 13.567 13.566 13.565 13.564

13.563 13.562 13.561 13.560 13.559 13.558 13.557 13.556 13.555 13.554

13.553 13.552 13.551 13.549 13.548 13.547 13.546 13.545 13.544 13.543

13.542 13.541 13.540 13.539 13.538 13.537 13.5’36 13.535 13.534 13.533

13.531 13.530 13.529 13.528 13.527 13.526 13.525 13.524 13.523 13.522

13,521 13.520 13.519 13.518 13.517 13.516 13.515 13.514 13.512 13.511

13.510 13.509 13.508 13.507 13.506 13.505 13.504 13.503 13.502 13.501

0’5 0-O 05

13.574 13.573

13.572 13,571 13.570 13.569 13.568 13.567 13.566 13.565 13.564 13.563

13.562 13.561 13,560 13.559 13.558 13.557 13.556 13,555 13.554 13.553

13,552 13.551 13.550 13.549 13.548 13.547 13.546 13.545 13.544 13.543

13.542 13.541 13.540 13.539 13.538 13.537 13.535 13.534 13.533 13.532

13.531 13.530 13.529 13.528 13.527 13,526 13.525 13.524 13.523 13.522

13,521 13.520 13.519 13.518 13.517 13.516 13.515 13.514 13.513 13.512

13.511 13.510 13.509 13.508 13.507 13,506 13.505 13.504 13.503 13.502

91

Page 96: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

Printed at Sree Saraswaty Press Ltd. (Under W. B. Government’s Management), Calcutta 700 009

Page 97: IS 8897 (1978): Tables for Calibration and Method …SHRI HARI DATTA The Ganga Glass Works Private Ltd, Balawali SHRI GIRDHARI LAL DHAMMY (Alternate) SHRI MOHINDER NATH National Physical

AMENDMENT NO. 1 JANUARY 2006TO

IS 8897:1978 TABLES FOR CALIBRATIONAND METHOD OF VERIFICATION OF VOLUMETRIC

GLASSWARE

( Page 3, F“oreword, clause 0.4 ) — Insert the following at the end of the> clause:

‘The coefficient of cubical expansion is the increase in volume per unit volumefor I“C rise in temperature. For ordinary work it is assumed that the coefficientofcubical expansion is about three times the coefficient of linear expansion.’

(Oi1310)

Reprography Uni~ BIS, New Delhl, India