is 3381 (1965): specification for cast vertical bollards
TRANSCRIPT
Disclosure to Promote the Right To Information
Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public.
इंटरनेट मानक
“!ान $ एक न' भारत का +नम-ण”Satyanarayan Gangaram Pitroda
“Invent a New India Using Knowledge”
“प0रा1 को छोड न' 5 तरफ”Jawaharlal Nehru
“Step Out From the Old to the New”
“जान1 का अ+धकार, जी1 का अ+धकार”Mazdoor Kisan Shakti Sangathan
“The Right to Information, The Right to Live”
“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता है”Bhartṛhari—Nītiśatakam
“Knowledge is such a treasure which cannot be stolen”
“Invent a New India Using Knowledge”
है”ह”ह
IS 3381 (1965): Specification for Cast Vertical BollardsWith and Without Lugs [TED 19: Marine Engineering andSafety Aids]
18:3381-1965
Indian Stan!dard ( Reaflimed 1987 b
SPECIFICATION FOR CAST VERTICALS BOLLARDS WITH AND WITHOUT LUGS
( Second Reprint JUNE 1992 )
UDC 629.12.014.24
@ Copyrigirt 19 6 6
BUREAU OFINDIAN STANDARDS MANAK BHAVAN. 9 BAHADUR SIIAH ZAFAR MA.RG
NEW DELHI 1 loo02
March 1966
IS I 3381- 1965
Indian Standard
SPECIFICATION FOR CAST VERTICAL BOLLARDS WITH Al$D WITHOUT SLUGS
Marine Engineering and Shipbuilding Sectional Committee, EDC 56
chainnan Rapmsding
REAR-ADY T. B. BOSE Jayanti Shipping Co Ltd, Calcutta
Members
CAPT P. ALEXANDEB The Company of Master Mariners of India, Bombay CAP% P. S. VANCH~WAB ( Alhmata )
Directorate General of Technical Development ( Ministry of Industry & Supply)
Bonar Bros & Co, Calcutta
SEBI F. V. BADAMI
SHBI K. BANEBJEI? SHEI P. R. DAVE Drn~crros OF MABIN~ EN~INB
EBINf3
Alcock Ashdown dr Co Ltd, Bombay Indian Navy
Hindustan Shipyard Ltd. Visakhapatnam Scindia Workshop Ltd, Bombay
Directorate General of Shipping ( Ministry of Tram- port ), Bombay
Directorate General of Shipping ( Ministry of Trans- port ), Bombay
Lloyd% Register of Shipping, Calcutta
.Institution of Marine Technologists, Bombay SHIU K. N. G. MBNON ( Alkmuca )
SEEI KIBPAL SINoH The Indian National Steamship Owners’ Association, Bombay
SEBI S. Y. KOTWAL Siemens Engineering and Manufacturing Co of India Ltd. Bombay
D~srscrros of NAVAL CONS- TBUoTION ( Alternub )
S~sr M. J. GoDIWALA SHBI F. D. Golana
SEBI T. A. SHAIKFF ( &Wlftt6 ) SEBI B. K. &PTA
CA& GUBUBAN SIXOH
SBBIB.HILL SEIU G. C~DD ( Aikrnak )
SlmI s. KAsTxWI
SEBI J. L. A~AEWAL ( Alkmak) ;z t LtiA~“D”“, Kirloskar Oil Engines Ltd, Poona
s&x v.X& ( Alt6mat6) AFCO ~Ltd, Bombay
SHBI Suiw MOL~~BEOY SaarX. PAI~Z!EASABATEY
Ahmed S. Moloobhoy &Sons, Bombay Directorate General of Shipping ( Mintstry of Tram-
port ), Bombay Smax J. G. PATELL Garden Reach Workshops Ltd, &lcutta
SEEI EDWABD RAJAUTNAY ( Alum& ) SEBI S. K. PAUL The Commissioners for the Port of Calcutta
SHBI A. SING-H (- Alkrnak ) Smm V. S. S. RAMA RAO
SHPI J.X. Srr?vY ( &66nUr6) .Rivers St&am Navigation Co Ltd, Galccittr
(c&W6dOnpaPr2)
BUREAU OF INDIAN STANDARDS MANAK BHAVAN. 9 BAHAWR SHAH
NEW DELHI llooolz
ZAFAR MARG
c
IS : 3381- 1965
( Continuedfrom page 1 )
Members
SRR1T.M. SANQHAVI SHRI SYDNEY G. SCHAE~~RB SHRI D. S. SHETH SHRI B.S.SOOD
SHRI M. SASSOON (Alternate) SHRI i%VELU
Representing
The Institute of Marine Engineers, Bombay American Bureau of Shipping, Bombay Hindustan Shipyard Ltd, Visakhapatnam Bombay Port Trust, Bombay
Central Institute of Fisheries Technology, Ernakulam
&RI B.D. WADIA SHRI K. A. IRANI ( Alternate )
SHRIM.V.P~TA~~KA& Deputy Director ( Mech, Eng )
The Shipping Corporation of India Ltd, Bombay
Director, ISI ( Ex-ojicio Member )
SecretaY~
SHRI K. S. SUBRAMAR~AW
Officer on Special Duty ( Mech Eng), IS1
Hull Installation Subcommittee, EDC 56 : 3
Convener
SERI M. G. KITTY Hindustan Shipyard Ltd, Visakhapatnam
Members
SHRI F. V. BADAMI Directorate General of Technical Development ( Ministry of Industry & Supply)
DIRECTOB OF NAVAL CONSTRU(I- Indian Navy TION
SHRI B. HILL SHRI R. MCINTOSH (hternatc)
Lloyd’s Register of Shipping, Calcutta
CAPT R. D. KOHLI The Shipping Corporation of India Ltd, Bombay CAPT M. K. NAMBIAR ( Alternate )
CAPT M. P. G. MENON The Company of Master Mariners of India, Bombay PROF S. C. MITRA Indian Institute of Technology, Kharagpur SHRI K. PARTHASARATHY Directorate General of Shipping (-Ministry of Trans-
port), Bombay SRRI J. G. PATELL Institution of Marine Technologists, Bombay DR T. S. RAQHURAM Mazagon Dock Ltd, Bombay
SERI H. C. SETHNA (Alternate)
Panel for Anchors, Anchor Chains and Anchoring Equipment, EDC 56 : 3/P-I
Conuencr SHRI M. G. KUTTY Hindustan Shipyard Ltd, Visakhapatnam
Members
SHRI D. H. DATR SHRI B. HILL ~P~orr S. C. MITRA
PROP P. K. PAL ( Alternate ) SEBI K. PARTHASARATHY
Mukand Iron & Steel Works Ltd, Bombay Lloyd’s Register of Shipping, Calcutta Indian Institute of Technology, Kharagpur
Directorate General of Shipping ( Ministry of Trans- port ), Bombay
2
IS : 3381- 1965
Indian Standard
SPECIFICATION FOR CAST VERTICAL BOLLARDS WITH AND WITHOUT LUGS
0. FOREWORD
0.1 This Indian Standard was adopted by the Indian Standards Institution oh 18 December -1965, after the draft finalized by the Marine Engineering and Shipbuilding Sectional Committee had been approved by the Mechani-, cal Engineering Division Council.
0.2 Bollards form a part of the mooring outfit required on board ships. The nominal size of cast bollards for the-ship is based on the admissible breaking load of ropes specified by the competent authority under whose rules the vessel is constructed. Cast vertical bollards are required to be provided with lugs when they are fitted in certain positions on board ships. Bollards fitted in other positions may or may not be provided with lugs depending upon owner’s requirements.
0.3 This standard is based on ISO/R 38 ‘ Bollards ( vertical type ) with and without lugs ‘, issued by International Organization for Standardi- zation.
0.4 For the purpose of deciding ,whether a particular requirement of this standard is complied with, the final value, observed or calculated, expres- singthe result of a test, shall be rounded off in accordance with IS : 2-1960*. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.
1. SCOPE
1.1 Thii standard specifies the material and dimensions for cast vertical bollards with and without lugs.
2. TERMINOLOGY
2.0 For the purpose of this standard, the following definition shall apply.
2.1 Nominal Ditieter-1 The nominal diameter of bollards is the out- side diameter of the bollard bar@ in millimetres.
*Rules for rounding off numerical valua ( revised), :
3
-..-.____
.ISz33Sl-1963
3. MATERIAL
5.1 Cast bollards shall either be made of cast iron or cast steel. Iron castings shall conform to Grade 25 of IS : 210-1962* and steel castings shall conform to IS : 2985-1964t. When mater-i& other than these two are used, the thickness shall be changed accordingly.
4. DIMENSIONS
4.1 The shape and dimensions of cast iron and cast steel bollards shall be asgiveninFig. 1 (~csP6) and2 (seeP9) andTables 1 and2 (seGP7) respectively.
4.2 The radii of fillets not shown in the tables shall be as large as possible and shall inno case be less than the thickness of adjacent material.
5. TOLERANCES
3.1 The height Hr may exceed the value given in the tables by. 50 mm maximum, unless otherwise stated by the purchaser.
5.2 The. thickness of ‘the material ‘in no case shall be less than thk specified value.
5.3 The tolerances on all other dimensions shall be according to the coarse series as given in IS : 2102-1962$.
5.4 .The finished weight of the cast bollard shall be not. less than the d- culated weight shown in Tables 1 and 2.
6. FINISH
6.1 The surface of the, bollard shall be finished smooth.
7. DESIGNA%ION
7.f Cast vertical bollards .shall be designated by its name, nominal dia- meter, material and number of this standard;
Cast vertical bollards having a nominal diameter 150 mm, made of cast ‘iron shall be designated as:
Cast Vertical Bollards 150 CI IS : 3381
*Specification fo; grey iron castings ( fmisrd).
tSp&fkation for steel wtings for ahip’s structure.
tol~&cs. ecommendations for machi&g deviations for dimensions without specified
4
I!3:3381-1965 .
8. MARKING
8.1 Cast vertical bollards shall be marked with nominal diameter and manufacturer’s other identification marks.
8.2 The cast vertical bollar& may also be marked with the IS1 Certification Mark.
NOPE - The me of the IS1 Certifxation Mark is governed by the provisions of the Indian Standards Institution ( Ccrtitication Marks ) Act, and the Rules and Regulations made thereunder. Presume of this mark on products covered by an Indian Standard conveys the assurance that they have been produced to comply with the requirements of that standard, under a well-defined system of inspection, testing and quality control during production. This system, which is devised and supervised by IS1 and operated by the producer, has the further safeguard that the products as actually marketed are continuously checked by IS1 for conformity to the standard. Details of conditions, under which a licence for the use of the IS1 Certification Mark may be granted to manufac- turers or processors, may bc obtained-from the Indian Standards Institution.
5
--..- ----.-.. .
TABLE 1 DIMENSIONS FOR CAST IBON BOLLARDS ( Clauses 4.1,5.4, and Fig. 1 and 2 )
IS : 3341- 1965 965
All dimensions in millimetres.
I \ T (
-
-
+F tonnes
LUO CALOTJ- LATED NEIGHT : WITH-
OUT Lnas ) (kg)
::
12
138 200 250 335
510 645 820
1 115
1 365 1.720 2060 2 470
FI~INCJ ARRANGEMJZNT I
BABBEL
Hs fl
1 Min
MAL DIA
D
-
‘a
Min
40
Z8 60
z
;:
105 130 155 180
205 230 !55 !80
No. of
Bola
s
6”
f 8 8
8 10 10 10
12 12
::
Bolt Hole Dia Dia
- Ml4 Ml4 M20 M22 M24 M24 M27 M27 M33 M33 M36 M39 M3’,
16 16
::
z f 3”:
:5 39 42
42 ._
150 190 290 270
z 335 370 450 500 570 650
720 775 835 895 -
-
4
-- - - - - - -
170
195 210 230 250 265 280 290 300
-
I5
- - - - -
- -
ii
40 40
:;
45
5”: 50 -
4
275 350 430 500 550 600 680 750
1 go” 1 100 1206
1300 1 400 1 600 1 700
Min.
-
-
;20 2”: 2! 2 40 42
::
50 50 50 50 -
4
100 135 170 200 230 260 290 320 380
zz 560
620 690 770 850
4
500
zz 800
1 zz I 100 1200 1 450 1650 1850 2050
2250 2400 2 750 2900
- -
-
1 1
-
--
pa La
-
145 170 200 230
470 300 330 360 430 500 560 630
700 770 900 970 -
r4
Mill -
- - -
-
80
105 120 140 160 180 200 220 240
Y
I ,
-
::
:; 45 52 57 66
G 102 114
126 138 150 162
130 150 165 180
205 240 325 350
420 250 275 285
305 320 270 280
- - - - -
60 i8 90
100
1od l.!O
:;:
- :
-
-
: ‘
-
1: 125 150
175 200 225 250 300 350 400 450 500 !~60 6iO 700
3.5
85:; 12.0
16-O 20
;;
Z!
:
115
:g 260
170 220 275 330
375 420
2:
590 665 735 790
:g 955
1000
l Fis tbC maximum admissible brea ng load of the corresponding rope.
TABLE 2 DIMENSIONS FOR CAST STEEL BOLLARDS ( cIcrusas4.~, 5.4, and Fig. 1 and 2 )
All dimensions in millimetres.
NOMS ETAL DIA
D
BAB~EL BASE LUG I FIXING ARBANQEMENT l F tonnes
12.0
:1 40
2:
1;:
g
-~- 500 38 30
600 750 2: z 900 78 55
1000 1 100 1:;
60 65
1 200 114 70 1300 126 80
1400 138 90 1 600 150 100 1700 160 110
‘S
Min
-
t5
- -
20 25
z; 30 35
z 40
MiI8
20 24 28 32
4”: 45 50
: 65
-
-
h
90 2 36
::
4”;
50 53 55 -
Bolt Dia
4
7-
ii 360 430
500 560 630 700
770
$0” -
74
Min
-1 -
80 D
105
120 140 1 160 180
200 220 240
_
-
-
--
-
-
B, No. of
Bolts
Pl pr
270 180 330 240 370 350 450 420
500 250 570 275 650 285 720 305
775 320 835 270 895 280
fl :1 k
L - -
Fa 70
80 90
100 100
110
!?I -
- -
170 195 210 230 250 265
280 290 300
L
-
-
-
-
150
% 300
350 400
4$
560 630 700
-
ii 430 552 750 955
1 310 1 650 2080
200 260 320 380
G
1!!
690 770 850
330 420 510 590
665 735’ 790 840
880 955
I 000 \
20
;i
28
%: 35
z 42
:;
:i 22
:: .27
29 30 32
800
: 1 0
1 ! 1;’ 3
2 050 2 250 2 400 2 750 29qo
60 75 90
105
130 155 180 205
230 255 280
M22 M24 M27 M33
M33 M36 M39 M39
M45 M48 M52
- F is the maximum admissible breaking load of the corresponding rope;
7
As in the Original Standard, this Page is Intentionally Left Blank
IS t 33819 1965
kF=&p
ARRANZEMEN? FOR’6 BOCTS
ARRANGEMENT FOR 8 BOLTS
ARRANGEMENT ~FOR 10 BOLTS
~+_:__________ ___.,, +,/_ _.,, ~,~__:,Q,,~_____________;,
2)
___ .__- .__-
*-’
\ ~~~_________.__.~-~,_~I-~,_*:O~~_____________ I
s -!- S ARRANGEMENT FOR 12 IiOLTS
I------ ?;-----A- ARRANGEMENT. FOR K’BOLTS
FIG. 2 AB~ANQEWEWZ OP Bh~e BOB DIlFPjEmm Smlos op:Bslp PLATE
,9
\ p:’
BUREAU 0F“INDIAN STANDARDsS
Headquarters : Mar& Bhavan. 9 Bahadur Shah Zafar Marg, NEW DELHI 110002
Telephones : 331 01 31 Telegrams : Manaksanstha
331 13 75 (Common to all Offibs)
Regional Offices : Telephone
Central : Manak Bhavan, 9. Bahadur Shah Zafar Marg 331 01 31 NEW DELHI I 10002 331 13 75
’ Eastern : l/l4 C.I.T. Scheme VII M. V.I.P. Road, Maniktola. CALCUTTA 700054
Northern : SC0 445-446, Sector 35-C, CHANDIGARH 160036 Southern
t Western : C.I.T. Campus, IV Cross Road, MADRAS 6001 I3 : Manakalaya, E9 MIDC. Marol. Andheri (East),
BOMBAY 400093
Brench Offices :
‘Pushpak’, Nurmohamed Shaikh Marg, Khanpur, AHMADABAD 380001 t Peenya Industrial Area, I st Stage. Bangalore-Tumkur Road.
BANGALORE 560058 Gangotri Complex, 5th Floor, Bhadbhada Road, T.T. Nagar.
BHOPAL 462003
Plot No. 82/83, Lewis Road, BHUBANESHWAR 751002 Kalai Kathir Building, 6/48-A Avanasi Road, COIMBATORE 641037 Quality Marking Centre, N.H. IV, N.I,T.. FARIDABAD 121001 Savitri Complex, 116 G. T. Road, ~GHAZIABAD 201001 53/5 Ward No. 29, R.G. Barua Road. 5th By-lane,
GUWAHATI 781003 S-8-56C L.~N. Gupta Marg, ( Nampally Station Road )
HYDERABAD 500001 R14 Yudhister Marg, C Scheme, JAIPUR 302005
117/418 B Sarvodaya Nagar, KANPUR 208005
Plot No. A-9, House No. 561/63. Sindhu Nagar. Kanpur Roao. LUCKNOW 226005
Patliputra Industrial Estate, PATNA 800013
District Industries Centre Complex, Bagh-e-Alihaidan, SRINAGAR 190011
T. C. No. 14/1421, University P.~O., Palayam. THtRUVANANTHAPURAM 695034
fnspection Offices (With Sale Point) : Pushpanjali. First Floor, 205-A West High Court broad.
Shankar Naaar Souare. ~NAGPUR 440010 Institution of insinkers ‘(India) Building, 1332 Shiuaji Nagar.
PUNE 411006
‘Sales Off ice Calctitta is at 5 Chowringhee Approach, P. 0. Princep Street, CALCUTTA
t Sales Office is at Novelty Chambers, Grant Road. ~BOMBAY
iA&;LEz~ is at Unity Building, Narasimharaja Square,
37 86 62
21843 41 29 I6
6 32 92 95 \
2 63 48 39 49 55
55 40 21
5 36 27 2 67 05
-
8-71 19 96 3 31 77
23 10 83
63471 21 68 76
5 5507
6 23D5
“,-6\21 04
52 51 71
5 24 35
Reprography Unit, BIS, New Delhi, India
27 68 00
89 65 28 22 39 71
.