invitation for bids cck-2484-20 addendum # 2 07/07/2020 · chemistry/physics building renovation...
TRANSCRIPT
University of Kentucky Purchasing Division 322 Peterson Service Building Lexington, KY 40506-0005
A n E q u a l O p p o r t u n i t y U n i v e r s i t y
INVITATION FOR BIDS
CCK-2484-20 ADDENDUM # 2
07/07/2020
ATTENTION: This is not an order. Read all instructions, terms and conditions carefully.
IMPORTANT: BID AND ADDENDUM MUST BE RECEIVED BY 07/14/2020 @ 3:00 P.M. LEXINGTON, KY TIME Bidder must acknowledge receipt of this and any addendum as stated in the Invitation for Bids. 1. Please refer to and incorporate within the offer, the attached documents for Addendum #2. 2. Important: In accordance with COVID-19 response, this solicitation will be opened publicly via Zoom only. Visit the Purchasing Division Bid and Opportunities website (http://www.uky.edu/Purchasing/bidlist.htm) to access the Zoom link. The Zoom link will be provided with the respective bid prior to the bid opening date and time.
OFFICIAL APPROVAL SIGNATURE UNIVERSITY OF KENTUCKY
________________________________________
______________________________________ ________________________________________
Procurement Manager / (859) 323-5405 Typed or Printed Name
Chemistry/Physics Building Renovation – Bid Package No. 2B UK Project No. 2446.1
University of Kentucky – Lexington, KY July 7, 2020
Addendum Number Two
Clarifications:
1. Scope Clarification – The scope of this bid package is only for the audiovisual components of this project as
defined in Form of Proposal: Trade Package #34 – Audiovisual. All other scopes of work for this project have
been bid in previous bid packages.
END OF ADDENDUM NO. 2
1 of 1
UK Chemistry-Physics Third Floor Renovation Bid Package 2B – Audiovisual
ADDENDUM #2 - AV July 7th, 2020
Item #1 Refer to the Audiovisual Specifications A. Revise Section 2.14.I to the following:
Basis of design: SHURE ULX-D (ULXD1 body pack, ULXD2 handheld, ULXD4 receiver), Sennheiser G4, AudioTechnica or equivalent
B. Revise Section 2.3 LCD Flat Panel Displays to the followingi. Panel Technology: S-IPSii. Viewable Image Size: 65” or as indicated.iii. Aspect Ratio: 16:9iv. Native Resolution: 3840x2160v. Supported Resolutions: UHD, 1080p at minimumvi. Brightness: 400 cd/m^2vii. Viewing Angle: 178 degree vertical, 178 degree horizontalviii. Refresh Rate 60Hzix. Operation: 24/7x. Warranty: 3 year parts & laborxi. Provide with tilting wall mount as specified.xii. Basis of Design: LG 65UT640S0UA (or size most close to those specified in this series of displays), NEC, Sharp or
equivalent.
END OF ADDENDA ITEMS
Written Questions and Answers – Page 1 of 5
Written Questions and Answers CCK-2484-20
#2446.1 Facilities Renewal, Modernization and Deferred Maintenance – Chemistry/Physics 3rd Floor Bid Package #2B – TP -34 Audiovisual
No. Question Answer
1.
WILL UK BE PROVIDING/INSTALLING A TWO GANG IN WALL JUNCTION BOX FOR ALL LOCATIONS (EXCEPT THE VIDEO WALL SYSTEM) OF THE EXTRON TLP PRO 725M TOUCH PANEL?
All rough ins are as shown on the plans. Refer to the Electrical Systems sheets along with the AV elevations for that information.
2. PAGE 2388 - 2,4,5 / T-2.0 INDICATES A SINGLE GANG ROUGH IN BOX (FOR THE EXTRON TLP PRO 725M TOUCH PANEL) TO BE INSTALLED. IS THIS AN ERROR?
The roughin is correct. The touchpanel will be mounted with the associated wall plate over the 1G roughin.
3.
PAGE 2388 – 2,3,4,5 / T-2.0 INDICATE THE ROUGH IN BOX (FOR THE EXTRON TLP PRO 725M TOUCH PANEL) TO BE PROVIDED BY AV INTEGRATOR. IS THIS AN ERROR?
The tag indicates that the single gang box is existing, the touchpanel is to be provided by the Integrator.
4.
PAGE 2389 – 4 / T-2.1 DRAWINGS IMPLY THE AUDIO FROM THE EXTRON SHARELINK PRO 500 TO BE PLAYED THROUGH THE MONITOR SPEAKERS. PLEASE CONFIRM.
Confirmed.
5.
PAGE 2389 – 4 / T-2.1 INDICATES A (UK PROVIDED) SMALL FORM FACTOR PC MOUNTED BEHIND DISPLAY. WHAT ARE THE ROUGH DIMENSIONS OF THIS DEVICE?
7.2” x 1.4” for the computer, plus the optiplex micro vesa mount.
6.
PAGE 2389 – 4 / T-2.1 INDICATES A (UK PROVIDED) SMALL FORM FACTOR PC MOUNTED BEHIND DISPLAY. WHAT TYPE OF FASTENING (PULL OUT SHELF, VELCRO DIRECT TO MONITOR CHASSIS, ETC.) IS REQUIRED?
This is means and methods and up to the installer.
7. PAGE 2385 1 / T-1.1c WHAT IS THE FINISHED CEILING HEIGHT OF THE VIDEO WALL SPACE THAT HOUSE THE CEILING SPEAKERS?
The finish ceiling elevation is 9’-0” aff.
8.
PAGE 230 (SECTION M) INDICATES MODEL ELO 5553L AND PAGE 2384 (A/V EQUIPMENT SCHEDULE) INDICATES MODEL ELO 5502L. WHICH MODEL DOES UK REQUIRE FOR THE SPACES UTILIZING THE ELO DISPLAYS?
Model 5553L is the basis of design, equipment schedule will be updated via addendum.
9. PAGE 236 (SECTION 2.14 – I ) INDICATES A SHURE GLX-D WIRELESS MIC SYSTEM AS A BASIS OF DESIGN.
Refer to addendum for clarification.
Written Questions and Answers – Page 2 of 5
THIS UNIT DOES NOT PROVIDE ANTENNA EXTENSION CAPABILITY. IS THIS AN ERROR?
10.
WHAT TYPE OF WIRELESS MIC CONFIGURATION IS REQUIRED FOR THE VIDEO WALL SYSTEM? (IE. COMBO, DUAL SYSTEM, ETC.) TO BE CLEAR, DO YOU WANT TO BE ABLE TO USE (2) MICROPHONES SIMULTANEOUSLY?
Yes, ability to use 2 microphones at once is required.
11.
PAGE 227 (SECTION C5) INDICATES A WIRELESS CONTROL INTERFACE (IPAD OR EQUIVALENT) REQUIRED BUT NO MENTION OF A WIRED TOUCH PANEL. IS THIS AN OMISSION?
Hardwired control panel is also required in addition to the wireless control. Hardwired touchpanel to be mounted at the rack location, this will be clarified in addendum.
12.
PAGE 227 (SECTION C5) INDICATES A WIRELESS CONTROL INTERFACE (IPAD OR EQUIVALENT) REQUIRED. IS UK PROVIDING THE IPAD OR EQUIVALENT? IF NOT, WHAT SIZE OF WIRELESS TABLET IS REQUIRED?
Integrator to provide this device and all licensing associated. Size is 9.7” minimum, 12” max.
13.
PAGE 227 (SECTION C5) INDICATES A WIRELESS CONTROL INTERFACE (IPAD OR EQUIVALENT) REQUIRED. IS THERE A SPECIFIC CHARGER OR DOCKING STATION REQUIRED?
No additional hardware is required for this wireless control interface. It will be kept in a location TBD by UK and utilize the charger that comes with it.
14.
PAGE 229 (SECTION 2.3 – N) INDICATES NEC C861Q (86”) AS THE BASIS OF DESIGN. PAGE 2384 INDICATES LG 65UT640S0UA (65”) IN THE A/V EQUIPMENT SCHEDULE. WHICH MONITOR SIZE IS REQUIRED?
65” displays are correct. Specification will be updated via addendum.
15. WILL YOU HAVE A NEED FOR HAZARDOUS MATERIALS SURVEY (ASBESTOS, LEAD, ETC.) AND/OR MONITORING ON THIS PROJECT?
No, this scope of work bid in a previous bid package.
16.
ON DRAWING T-2.1, THE MANUFACTURE IS NOT SPELLED OUT FOR THE VIDEO WALL OR ASSOCIATED SOUND EQUIPMENT OTHER THAN THE JBL COLUMN SPEAKERS. ARE THE REMAINING COMPONENTS DESIGN BUILD? IS THE TP-34 SPELLED OUT, OR ONLY ON THE SHOWN ON THE DRAWINGS?
Refer to specifications for basis of design manufacturers along with all of the remaining information requested here. The Trade Package #34 language is included in bid documents and can be found on pages 60-64 of the download.
17.
SINCE THIS IS A STATE BUILDING, WILL A LOW VOLTAGE PERMIT BE REQUIRED FOR TP-34 AUDIO-VISUAL PACKAGE?
Bidders are responsible for determining if a permit is required.
18. SPECIFICATION 272416 2.3 LCD FLAT PANEL CALL FOR NEC 86” DISPLAYS. DRAWING T1.0 CALL OUT LG 65” DISPLAYS. WILL YOU CLARIFY THIS CONFLICT?
65” displays are correct. Specification will be updated via addendum.
Written Questions and Answers – Page 3 of 5
19.
DRAWING T2.1 DETAIL # 2 INDICATES THAT THE KORBYT ARIES MEDIA PLAYER WILL BE OFCI. IT ALSO STATES UNDER THE DISPLAY’S PICTURE THAT THE MEDIA PLAYER W/ LICENSE WILL BE PROVIDED BY THE INTEGRATOR. WILL YOU CLARIFY THIS CONFLICT?
The player and license will be owner provided. Drawings will be updated to reflect this.
20.
SPECIFICATION 272416 3.2 EQUIPMENT RACKS: IS THE INTEGRATOR TO CHOOSE MFG., DATA RACK HEIGHT, OPEN DATA 2 OR 4 POST STYLE, ETC. TO HOUSE AUDIO VISUAL EQUIPMENT?
Refer to drawing T2.1, equipment is to be located in UK ITS rack, no rack is to be provided by AV Integrator.
21.
WILL U-K PROVIDE A NETWORK SWITCH FOR THE VIDEO WALL SYSTEM AV OVER IP VIDEO DISTRIBUTION ENCODERS & DECODERS?
No, switch is to be provided by integrator for a closed system to support video transport.
22.
SUBSTITUTION REQUEST: WE’D LIKE TO REQUEST THE FOLLOWING PRODUCTS BE CONSIDERED AS APPROVED EQUALS FOR THE LCD VIDEO WALL CONFIGURATION: CHRISTIE FHD EXTREME SERIES https://www.christiedigital.com/products/lcd-video-walls/extreme-series/
Approved.
23.
SUBSTITUTION REQUEST: FOR THE DIRECT VIEW LED ALTERNATE WE’D ALSO LIKE TO REQUEST AS APPROVED EQUALS: CHRISTIE CORE SERIES LED 135” DIAGONAL 1.5 MM https://www.christiedigital.com/products/led-video-walls/core-series/ MAX HUB 110” LM110M07 https://www.maxhub.com/en/led/
Approved. 110” MaxHub is not close enough to the dimensions, the Max Hub 138” is approved.
24.
SUBSTITUTION REQUEST: FOR THE DIGITAL SIGNAGE TOUCH DISPLAYS WE REQUEST: CHRISTIE ACCESS SERIES UHD551-L, 55" UHD, OPS SLOT, LANDSCAPE ONLY, 16/7, 400 NITS 9 TOUCH OVERLAY FOR 55" UHD551-L, 10-POINT TOUCH, USB CONNECTION https://www.christiedigital.com/products/lcd-panels/access-series/christie-uhd551-l/
Approved.
Written Questions and Answers – Page 4 of 5
25.
SUBSTITUTION REQUEST: FOR THE VIDEO WALL PROCESSOR: CHRISTIE TERRA https://www.christiedigital.com/products/switchers-av-distribution/terra-transmitter/overview
Approved.
26.
SUBSTITUTION REQUEST: FOR FLAT PANEL DISPLAYS CHRISTIE ACCESS SERIES UHD861-P WITH A TOUCH OVERLAY https://www.christiedigital.com/products/lcd-panels/access-series/christie-uhd861-p/overview
Approved.
27.
What is the basis of design for the All in One Video Teleconferencing System? Drawing T.2.1 Calls out Logitech Meet-Up System
Logitech Meet-Up is the basis of design.
28.
IN LIGHT OF COVID 19, WILL ONSITE ATTENDANCE BE REQUIRED AT COMMUNICATION PROGRESS MEETINGS OR WILL PROVISION BE MADE FOR VIDEO CONFERENCING?
On-site attendance will not be required for progress meetings and video conferencing will be made available.
29.
I WOULD LIKE TO ADD SHAFFNER HEANEY ASSOCIATES, SHAPE ACM PRODUCT AS AN APPROVED COMPOSITE METAL WALL PANEL FOR THIS PROJECT
There are no metal panel systems to bid in this trade package.
30.
TECHNICAL: PLEASE CONFIRM THE PATHWAYS AND CABLING ARE PROVIDED BY OTHERS. PLEASE CLARIFY WHICH MODEL SHOULD BE PROVIDED. THE SCHEDULE LISTS AN ELO 5502L AND THE SPECIFICATION LISTS AND ELO 5553L. WHICH IS CORRECT?
All cabling for the AV scope of work is to be provided by the AV contractor. There are pathways provided by others, but any additional pathways needed to complete the AV scope of work is to be provided by the AV contractor.
31.
ADMINISTRATIVE: RE: MBE/WBE PARTICIPATION: WE CONTACTED THE UK FACILITIES MANAGEMENT CONTRACTOR/SUPPLY CHAIN COORDINATOR FOR A LISTING OF THESE FIRMS; THEY ARE NOT AWARE OF A LISTING. DUE TO THE TRAINING REQUIREMENTS ON THESE TYPES OF SYSTEMS AND TECHNICAL NATURE OF THIS PROJECT, PLEASE CONFIRM THIS IS A REQUIREMENT.
MBE/WBE Participation Goals PART 4 - OBLIGATION OF BIDDER 4.1 The bidder shall make a Good Faith Effort to achieve the Participation Goal for MBE/WBE subcontractors/suppliers. The failure to meet the goal shall not necessarily be cause for disqualification of the bidder; however, bidders not meeting the goal are required to furnish with their bids written documentation of their Good Faith Efforts to do so.
Written Questions and Answers – Page 5 of 5
32.
DURING THE PRE-BID MEETING HELD ON JUNE 25, WEHR CONSTRUCTION STATED THAT WE WOULD RECEIVE A COPY OF THE CONSTRUCTION SCHEDULE. COULD THAT PLEASE BE PROVIDED?
The construction schedule is included in the bid documents. Please reference pages 213 – 222 in the download.
33.
PLEASE VERIFY IF THE S98 NOTE OUTSIDE ROOM 345 IS CORRECT. BASED ON THE DRAWING, IT APPEARS A COLLABORATION SYSTEM IS NEEDED OUTSIDE THE ROOM.
This note is accurate, the system is for the collaboration area outside Rm 345.
34.
PLEASE VERIFY IF INTEGRATORS SHOULD UTILIZE THE SPECIFICATIONS OR THE DRAWINGS FOR DISPLAY SIZES. THE SPECIFICATIONS LIST AN 86” NEC DISPLAY, BUT THE DRAWING NOTES A 65” LG DISPLAY.
65” displays are correct. Specification will be updated via addendum.
35.
IS THE INTEGRATOR RESPONSIBLE FOR PROVIDING BACKBOXES? IF SO, WHO IS RESPONSIBLE FOR INSTALLATION?
AV wall boxes are by the electrical contractor. They will be existing when av integrator installation occurs.
36. ON THE ELO INTERACTIVE DISPLAY, WHICH TOUCH TECHNOLOGY DO YOU WANT, IR OR PCAP?
Per specification section 2.4.B. – PCAP.
37. THE VIDEO WALL QSC CXD4.2-XX AMPLIFIER DOES NOT HAVE A 70V OUTPUT CHANNEL. WHAT IS YOUR SOLUTION FOR THE [4] QSC 70V CEILING SPEAKERS?
The speakers specified have 16 ohm bypass.
38. HOW MANY RACK HEIGHT UNIT SHOULD I ALLOW FOR THE TBD OWNER FURNISH VIDEO WALL SOURCE EQUIPMENT?
4RU
39.
EQUIPMENT RACK EXISTING OR BY AV CONTRACTOR? SECTION 3.2, ITEM C DISCUSSES INSTALLING EQUIPMENT FOR THE VIDEOWALL IN DATA RACKS. NEITHER THE AV SERIES DRAWINGS, NOR THE SPECIFICATIONS DETAIL OR QUANTIFY AN EQUIPMENT RACK. PLEASE CONFIRM THAT THE EQUIPMENT RACK IS NOT REQUIRED. IF THE EQUIPMENT RACK IS REQUIRED FOR THE AV SYSTEM, PLEASE PROVIDE ADDITIONAL INFORMATION SPECIFYING THE MANUFACTURER AND MODEL NUMBER.
Refer to drawing T2.1, equipment is to be located in UK ITS rack, no rack is to be provided by AV Integrator.
40.
WALL PLATES EXISTING OR BY AV CONTRACTOR? DRAWING T-2.1, DETAIL 2 SHOWS A WALL PLATE, BUT DOES NOT SPECIFY IF THIS PLATE IS EXISTING OR PROVIDED BY THE AV CONTRACTOR. IF THE WALL PLATE IS REQUIRED FOR THE AV SYSTEM, PLEASE PROVIDE ADDITIONAL INFORMATION REGARDING THE INTEGRATION OF THIS EQUIPMENT INTO THE AV SYSTEMS.
The UK data wall plate shown in 2/T-2.1 is an existing data drop in a wallbox for network connectivity to UK’s Digital Signage VLAN by UK ITS.
GENERAL AV NOTES:
1. SCOPE
A. AUDIOVISUAL SCOPE OF WORK SHALL INCLUDE:
A. INSTALLATION AND TESTING OF ALL AUDIOVISUAL CABLING AND EQUIPMENT, INCLUDING BUTNOT LIMITED TO MONITORS, AUDIO COMPONENTS, MATRIX SWITCHES, DISTRIBUTIONAMPLIFIERS, EQUALIZERS, CENTRAL CONTROLLERS, INTERFACES, EQUIPMENT RACKS, ANDHARDWARE. ANY ITEMS NOT CALLED OUT THAT ARE NECESSARY FOR A COMPLETE ANDFUNCTIONING AV SYSTEM PER DESIGN INTENT SHALL BE INCLUDED.
B. AUDIOVISUAL CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL CONTRACTOR FORPOWER AND CONDUIT REQUIREMENTS.
C. AUDIOVISUAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR FORINSTALLATION OF WALL MOUNTED PLYWOOD FOR DEVICES AND MOUNTING OF DISPLAYS.
D. AUDIOVISUAL CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL DRAWINGS FORMOUNTING OF MONITORS AND DISPLAYS.
E. AUDIOVISUAL CONTRACTOR SHALL PROVIDE AND INSTALL J-HOOKS OR SIMILAR CABLEMANAGEMENT IN AREAS THAT HAVE TILE CEILINGS.
B. GENERAL CONTRACTOR SCOPE OF WORK SHALL INCLUDE:
A. INSTALLATION OF ALL CONDUITS, BACK BOXES, CONDUIT STUB-UPS, GROUND BARS,GROUNDING EQUIPMENT, AND POWER FOR AUDIOVISUAL EQUIPMENT. COORDINATE WITHELECTRICAL DRAWINGS.
B. INSTALLATION OF FLOOR BOXES OR RACEWAY AS SHOWN ON DRAWINGS.
C. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL AUDIOVISUAL INSTALLATION ANDOVERSIGHT.
2. GENERAL CONDITIONS
A. ALL AUDIOVISUAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ANSI/TIA – 568C“COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD”, TIA - 569B “COMMERCIALBUILDING STANDARD FOR TELECOMMUNICATIONS PATHWAYS AND SPACES”, EIA/TIA - 606“ADMINISTRATION STANDARD FOR THE TELECOMMUNICATIONS INFRASTRUCTURE OF COMMERCIALBUILDINGS”, EIA/TIA - 607 “COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FORTELECOMMUNICATIONS”, TIA/EIA - 75 HORIZONTAL PATHWAYS, AND BICSI “TELECOMMUNICATIONSDISTRIBUTION MANUAL".
B. THE DRAWINGS, WHICH CONSTITUTE A PART OF THIS CONTRACT, INDICATE THE GENERALARRANGEMENT OF CABLING AND OUTLETS, LOCATIONS OF EQUIPMENT, AND OTHER WORK. ALLITEMS NOT SPECIFICALLY MENTIONED HEREIN, WHICH ARE NECESSARY FOR A COMPLETEAUDIOVISUAL SYSTEM SHALL BE INCLUDED AT NO ADDITIONAL COST.
C. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE ARCHITECTURAL,STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS TO BECOME FAMILIAR WITHALL ASPECTS OF THESE DESIGNS AFFECTING THIS WORK. THE AUDIOVISUAL CONTRACTOR ISRESPONSIBLE FOR COORDINATION WITH ALL OTHER TRADES AND IS REQUIRED TO ATTENDSCHEDULED WEEKLY MEETINGS.
D. ALL AUDIOVISUAL MATERIAL SHALL BE NEW, DEFECTIVE EQUIPMENT OR EQUIPMENT THAT ISDAMAGED IN THE COURSE OF INSULATION OR TESTING SHALL BE REPLACED OR REPAIRED IN AMANNER MEETING THE APPROVAL OF THE OWNER. WHERE APPLICABLE, ALL EQUIPMENT SHE’LL BEIN ACCORDANCE WITH NEMA AND UL STANDARDS.
E. ALL WORK SHALL BE SUBJECT TO APPROVAL OF THE OWNER OR THE OWNER’S AUTHORIZEDREPRESENTATIVE.
F. ALL WORK SHALL BE INSTALLED IN A NEED AND WORKMAN LIKE MANNER. ALL SPACES SHALL BELEFT CLEAN, SWEPT AND FREE OF ANY DEBRIS, SCRATCHES, OR MARKINGS.
G. WHERE CABLING AND OR CONDUIT PASSES THROUGH FIRE RATED PARTITIONS OR SLABS, INSTALLFIRE STOP MATERIALS RATED TO MEET OR EXCEED THE RATING OF THE STRUCTURE PENETRATED.FIRE STOP MATERIALS SHALL HAVE BEEN TESTED FOR UL 1479 AND ASTM E-814. FOR SLEEVES,INSTALL EITHER A MECHANICAL FIRE STOP, INTUMESCENT FIRE STOP PILLOWS OR A COMBINATIONOF INTUMESCENT PUTTY AND MINERAL WOOD/CERAMIC FIBER. FOR SLOTS OR LARGER OPENINGS,INSTALL EITHER A MECHANICAL FIRE STOP OR A RATED ASSEMBLY SUITABLE FOR THE TYPE OFOPENING TO BE PROTECTED.
3. PATHWAY REQUIREMENTS
A. INSTALL AUDIOVISUAL CABLES IN WALLS USING CONDUIT STUB UPS AS SHOWN ON DRAWINGS.
B. INSTALL AUDIOVISUAL CABLES IN CEILING USING CONDUIT AND/OR J-HOOKS AS SHOWN ONDRAWINGS.
C. ROUTE ALL CABLES INSIDE FURNITURE USING ACCESS AREAS PROVIDED BY THE MANUFACTURER.COORDINATE WITH FURNITURE INSTALLER.
D. OBTAIN WRITTEN PERMISSION FROM STRUCTURAL ENGINEER PRIOR TO PENETRATING SLABS ORLOAD BEARING WALLS.
4. INSTALLATION PRACTICES
A. MANUFACTURER AND TIAA 568B RECOMMENDATIONS FOR CABLING BEND RADIUS SHALL BEFOLLOWED AT ALL TIMES.
B. DO NOT EXCEED THE MAXIMUM PULLING TENSION SPECIFIED FOR COPPER CABLE BY ITSMANUFACTURER.
C. ALL TIE WRAPS SHALL BE PLENUM RATED VELCRO WRAPS. PLASTIC TIE WRAPS ARE NOTPERMITTED.
D. TIE WRAPS SHALL NOT INCREASE THE TENSION OF THE CABLE OR OF ANY INDIVIDUAL PAIRS WITHIN A CABLE. ANY TIE WRAPS CINCHED SO TIGHTLY AS TO CAUSE AN INDENTATION OR DECREASE INCABLE DIAMETER SHALL BE REMOVED. ALL TIE WRAPS SHALL BE LOOSE ENOUGH TO MOVE ORSLIDE WITHOUT MOVING THE CABLE. EACH TIE WRAP SHALL HAVE 1/4 - 1/2 INCH SLACK, SO AS TOALLOW A FINGER TO PASS UNDER IT. AMOUNT OF THE TIE WRAPS USED SHALL BE MINIMIZED ANDPLACED WITH VARYING SPACING. EVENLY SPACED TIE WRAPS CAN REDUCE CABLE PLANTPERFORMANCE.
E. MAINTAIN THE SHEATH OF EACH INDIVIDUAL CABLE UP TO THE POINT OF TERMINATION BYREMOVING ONLY AS MUCH CABLE SHEATH AS NECESSARY AND PRACTICAL TO TERMINATE THECABLES.
F. ALL AUDIOVISUAL CABLING INSTALLED IN CEILING SHALL BE PLENUM RATED.
G. SUPPORT CABLE OFF THE FLOOR UNTIL TERMINATION. CABLING THAT HAS BEEN WALKED ONSHALL BE REPLACED.
H. AUDIOVISUAL WORK SHALL BE SEQUENCED TO AVOID ANY WORK ABOVE INSTALLED CEILING TILESOR OVER INSTALLED FURNITURE/CASEWORK.
5. CABLING
A. SUPPORT ALL AV CABLES ON J HOOKS OR ROUTE IN CONDUIT AS SHOWN ON THE DRAWINGS.
B. AUDIOVISUAL CONTRACTOR SHALL PROVIDE ADEQUATE LENGTH OF CABLING AT EQUIPMENTLOCATIONS TO FACILITATE MOVEMENT OF EQUIPMENT FOR MAINTENANCE WITHOUT REMOVING
CABLES.
C. IN CONFERENCE AREAS, AUDIOVISUAL CONTRACTOR SHALL PROVIDE AND INSTALL CONNECTORSAND CABLES TO FLOOR BOXES, OUTLETS, AND POKE THRUS AS SHOWN ON DRAWINGS. PROVIDE
INSERTS AND COORDINATE WITH TELECOM INSTALLER.
D. COORDINATE ALL CABLE JACKET COLORS WITH THE OWNER AND OTHER TRADES.
E. STRUCTURED CABLING CONTRACTOR MUST COORDINATE BACK BOXES, CONDUIT, SLEEVES, ETC.
F. ALL DATA, VOICE AND CATV/SATV CABLING, FACE PLATES, CONNECTORS, JACKS AND PATCHCABLES REQUIRED FOR THE AUDIOVISUAL SYSTEM SHALL BE PROVIDED AND INSTALLED BY THE
STRUCTURED CABLING CONTRACTOR.
G. ALL CABLING SUPPORTS FOR THE DATA, VOICE AND CATV/SATV CABLING FOR AUDIOVISUAL SYSTEMS SHALL BE PROVIDED AND INSTALLED BY THE STRUCTURED CABLING CONTRACTOR.
6. CONDUIT
A. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL METALLIC CONDUIT WITH MY FLOORS AS SHOWN ON DRAWINGS.
B. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL PULL BOXES AS SHOWN ON DRAWINGS.
C. COORDINATE WITH THE INSTALLATION OF ELECTRICAL AND MECHANICAL CONDUITS AND HVAC DUCTWORK SHARING THE SAME CEILING AREA.
D. REMOVE ALL SHARP EDGES AND BURRS FROM END OF CONDUITS AND FIT WITH BUSHINGS.
7. GROUNDING
A. THE AUDIOVISUAL CONTRACTOR SHALL GROUND ALL EQUIPMENT RACKS TO ELECTRICALCONTRACTOR SUPPLIED GROUND BUS BAR.
B. ALL GROUND WIRES AND CABLES SHALL BE TERMINATED IN CONNECTORS PER EXCEPTED PRACTICES. UNDER NO CIRCUMSTANCES SHALL DRAIN WIRES BE CUT. ANY DIFFICULTIES DUE TO GROUND POTENTIAL DIFFERENCES ARE TO BE BROUGHT TO THE ATTENTION OF THE OWNER.
8. SYSTEM AND PROGRAMMING
A. THE AUDIOVISUAL CONTRACTOR SHALL PROVIDE COMPLETE SYSTEM PROGRAMMING FOR THE CONTROLLERS AND ALL DEVICES INSTALLED. PROGRAMMING SHALL BE ACCOMPLISHED IN COORDINATION WITH TENANTS. PROJECT SHOULD NOT BE DEEMED COMPLETE AND EXCEPTED WITHOUT TENANT APPROVAL OF THE PROGRAMMING AND INTERFACES.
B. THE AV CONTRACTOR SHALL PROVIDE ALL PROGRAMMING SOURCE CODE TO THE OWNER UPONCOMPLETION OF THE PROJECTION.
C. THE AV CONTRACTOR SHALL CREATE AND PROVIDE FIVE ELECTRONIC USB THUMB DRIVE COPIESOF USER MANUALS DESCRIBING THE OPERATION OF EACH TYPE OF SYSTEM.
D. THE AV CONTRACTOR SHALL PROVIDE TRAINING FOR AT LEAST FIVE REPRESENTATIVES OF THEOWNER FOR EACH TYPE OF SYSTEM. TRAINING SHALL BE A MINIMUM OF FOUR (4) HOURS PER PERSON.
E. OWNER WILL REQUIRE A FULL-FUNCTIONAL COMMISSIONING TEST DEMONSTRATING OPERATIONOF ALL DEVICES PRIOR TO SYSTEM ACCEPTANCE.
F. ALL PROJECTORS SHALL HAVE A SCHEDULED SHUT OFF PROGRAM TO PRESERVE LIFE.COORDINATE WITH TENANT FOR SHUT OFF SCHEDULE.
G. ALL NETWORK SWITCHES, ROUTERS, PATCHING AND CONFIGURATION OF THE OWNERS NETWORK(FOR THE AUDIOVISUAL SYSTEMS) SHALL BE PROVIDED, INSTALLED AND CONFIGURED BY THE OWNER.
H. ALL VOIP INTEGRATION AND CONFIGURATION WITH THE OWNERS VOIP SERVER/PBX AND THE AUDIOVISUAL CONFERENCING SIP ENDPOINTS SHALL BE PROVIDED BY THE OWNER.
I. THE OWNER SHALL PROVIDE A RANGE (QTY TBD) OF STATIC IP ADDRESSES WITH A DEDICATED AUDIOVISUAL VLANS (QTY TBD) FOR THE AUDIOVISUAL SYSTEMS.
9. SITE VISIT
A. PRIOR TO SUBMITTING BIDS, THE AUDIOVISUAL CONTRACTOR SHALL VISIT THE SITE ANDFAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. THE AUDIOVISUAL CONTRACTOR SHALLNOTIFY THE ARCHITECT AND/OR THE ENGINEER IN ADVANCE OF ANY CONDITION THAT EXISTS THATWOULD PREVENT THE WORK HEREIN SPECIFIED OR SHOWN ON THE DRAWINGS FROM BEINGPERFORMED. FAILURE TO SURVEY THE SITE PRIOR TO BID AND START OF CONSTRUCTION WILL NOTRELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO INSTALL DESIGN WITHIN THE CONFINES OFEXISTING CONDITIONS.
10. GUARANTEE
A. THE AUDIOVISUAL CONTRACTOR SHALL LEAVE THE ENTIRE AUDIOVISUAL SYSTEM INSTALLEDUNDER THIS CONTRACT IN PROPER WORKING ORDER AND SHALL, WITHOUT CHARGE, REPLACE ANYWORK OR MATERIALS WHICH DEVELOP DEFECTS, EXCEPT FROM ORDINARY WEAR AND TEAR,WITHIN ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE. BENEFICIAL USE SHALL NOT BE
CONSTRUED AS FINAL ACCEPTANCE.
B. THE AUDIOVISUAL CONTRACTOR SHALL, DURING THE ONE-YEAR GUARANTEE, BE RESPONSIBLEFOR THE PROPER REPAIR AND ADJUSTMENTS OF ALL AUDIOVISUAL SYSTEMS AND EQUIPMENT,APPARATUS, DEVICES, ETC., INSTALLED BY HIM, AND DO ALL WORK NECESSARY TO ENSUREEFFICIENT AND PROPER FUNCTIONING.
C. PRIOR TO THE EXPIRATION OF THE GUARANTEE, APPROXIMATELY 11 MONTHS AFTER FINALACCEPTANCE OF THIS PROJECT, A POST-CONSTRUCTION REVIEW OF THE PROJECT WILL BE MADE.THE CONTRACTOR SHALL FURNISH PERSONNEL TO ASSIST THE OWNER IN THIS REVIEW. ANYADJUSTMENTS, REPAIRS, OR REPLACEMENTS FOUND NECESSARY DURING REVIEW SHALL BE DONEBY THE CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER.
D. THE AUDIOVISUAL CONTRACTOR SHALL BE RESPONSIBLE FOR, AND SHALL INCUR FINANCIALRESPONSIBILITY FOR ANY DAMAGES CAUSED BY, OR RELATING FROM, DEFECTS IN HIS WORK.
11. RECORD DRAWINGS
A. THE A/V CONTRACTOR SHALL MAINTAIN AT THE SITE, FOR THE OWNER, ONE COPY OF ALLDRAWINGS, ADDENDA, APPROVED SHOP DRAWINGS, REVISIONS AND OTHER MODIFICATIONS, INGOOD ORDER AND MARKED TO RECORD ALL CHANGES MADE DURING CONSTRUCTION. ONE SET OFDRAWINGS AND ANY OTHER INFORMATION SHALL BE DELIVERED TO THE OWNER VIA USB THUMBDRIVE UPON COMPLETION OF WORK.
PL
AN
NO
RT
H
TRUE N
ORTH
AU
DIO
/VIS
UA
L:
CH
EM
IST
RY
-P
HY
SIC
S R
EN
OV
AT
ION
Th
is D
raw
ing a
nd th
e D
esig
n s
how
n
there
on
are
th
e p
rope
rty o
f O
mni
Arc
hitects
. T
he r
ep
rodu
ction
, cop
yin
g
or
oth
er
use
of
this
Dra
win
g o
r D
esig
n
with
out th
e w
ritten
con
sen
t o
f O
mn
i A
rch
itects
is p
rohib
ite
d.
Job N
um
ber:
Le
xin
gto
n,
Ke
ntu
cky
212
No
rth U
pp
er
Str
ee
tL
exin
gto
n,
Ke
ntu
cky
405
07-1
00
1p
85
9.2
52
.666
4w
ww
.om
nia
rchitects
.co
m
Revis
ion:
BID DOCUMENTS
BID
DO
CU
ME
NT
S
T-1.0
AU
DIO
/VIS
UA
L L
EG
EN
DX
KC
P17-0
1M
AY
18, 2020
AUDIO/VISUAL EQUIPMENT SCHEDULE
ROOM NAME
ROOM
NUMBER TAG DISPLAY TYPE MANUFACTURER MODEL MOUNT MODEL QUANTITY
ATRIUM 300A FPD-7 WALL MOUNTED COLLEGE DISPLAY LG 65UT640S0UA CHIEF LTM1U 1
CORRIDOR SOUTH 300B FPD-5 WALL MOUNTED INFORMATION DISPLAY ELO 5553L CHIEF MTM1U 1
CORRIDOR SOUTH 300B FPD-7 WALL MOUNTED COLLEGE DISPLAY LG 65UT640S0UA CHIEF LTM1U 1
CORRIDOR SOUTH 300B FPD-5 WALL MOUNTED INFORMATION DISPLAY ELO 5553L CHIEF MTM1U 1
CORRIDOR SOUTH 300B FPD-5 WALL MOUNTED INFORMATION DISPLAY ELO 5553L CHIEF MTM1U 1
COLLABORATION AREA 300B1 FPD-7 WALL MOUNTED COLLEGE DISPLAY LG 65UT640S0UA CHIEF LTM1U 1
COLLABORATION AREA 300B2 FPD-7 WALL MOUNTED COLLEGE DISPLAY LG 65UT640S0UA CHIEF LTM1U 1
COLLABORATION AREA 300C3 FPD-7 WALL MOUNTED COLLEGE DISPLAY LG 65UT640S0UA CHIEF LTM1U 1
COLLABORATION AREA 300E1 FPD-7 WALL MOUNTED COLLEGE DISPLAY LG 65UT640S0UA CHIEF LTM1U 1
CORRIDOR EAST 300F FPD-5 WALL MOUNTED INFORMATION DISPLAY ELO 5553L CHIEF MTM1U 1
CORRIDOR EAST 300F FPD-5 WALL MOUNTED INFORMATION DISPLAY ELO 5553L CHIEF MTM1U 1
COLLABORATION AREA 300F1 FPD-7 WALL MOUNTED COLLEGE DISPLAY LG 65UT640S0UA CHIEF LTM1U 1
COLLABORATION AREA 300F2 FPD-7 WALL MOUNTED COLLEGE DISPLAY LG 65UT640S0UA CHIEF LTM1U 1
SOUTH CAFE 301 FPD-6 WALL MOUNTED CONFERENCE DISPLAY LG 65UT640S0UA CHIEF TS318TU W/ CHIEF PSBUB 1
CONFERENCE 302 FPD-6 WALL MOUNTED CONFERENCE DISPLAY LG 65UT640S0UA CHIEF TS318TU W/ CHIEF PSBUB 1
CONFERENCE ROOM 303 FPD-6 WALL MOUNTED CONFERENCE DISPLAY LG 65UT640S0UA CHIEF TS318TU W/ CHIEF PSBUB 1
NORTH CAFE 337 FPD-7 WALL MOUNTED COLLEGE DISPLAY LG 65UT640S0UA CHIEF LTM1U 1
CONFERENCE 338 FPD-6 WALL MOUNTED CONFERENCE DISPLAY LG 65UT640S0UA CHIEF TS318TU W/ CHIEF PSBUB 1
COMPUTATIONAL LAB - KEKENES - HUSKY 341 FPD-7 WALL MOUNTED COLLEGE DISPLAY LG 65UT640S0UA CHIEF LTM1U 1
CONFERENCE 378A FPD-6 WALL MOUNTED CONFERENCE DISPLAY LG 65UT640S0UA CHIEF TS318TU W/ CHIEF PSBUB 1
CONFERENCE 378B FPD-6 WALL MOUNTED CONFERENCE DISPLAY LG 65UT640S0UA CHIEF TS318TU W/ CHIEF PSBUB 1
FACULTY LOUNGE 397 FPD-6 WALL MOUNTED CONFERENCE DISPLAY LG 65UT640S0UA CHIEF TS318TU W/ CHIEF PSBUB 1
2
2
2
Revision Schedule
No. Revision Date
2 Chemistry/Physics Bid Package #2B Addendum 2
2020-07-02
M
S
S
S
S
98
C
10 11
E
D
H
J
C
D
E
G
H
J
7 8 9 10 11
9a'
D.01
D1
D2
7a 8a 9a9'6' 7' 8' 10' 11'9b9b'9a''
C.6
K
12
E.2
10.2 11.4 12.1
D.5
D.9
S11
S68
S58
S58
S58
S89
CORR
100F
CLASSROOM
139
VAULT
125A
OFFICE SERVICE
125B
STORAGE
127B
OFFICE
127A
TOILET
129
OFFICE
127
SERVICE CLOSET
138
OFFICE
144
ENTRY
142A
MEN
142
STAIR-D
ST-D
VESTIBULE
100A1
EINSTEIN'S SERVICE
101A
EINSTEIN'S SUPPORT
102A
VESTIBULE
100A2
ELEC
100F
DW1
263JJ
CLASSROOM
153
WOMEN
130
OFFICE
150OFFICE
148D
OFFICE
148C
OFFICE
148B
OFFICE
148A
RESEARCH
148D1
RESEARCH
148A1
INSTRUMENT ROOM
146
X-RAY LAB
146A
COMMUNICATIONS
128
DEVELOPING ROOM
146A1
STORAGE
151
STORAGE
149OFFICE
135
PHYSICS LEARNING CENTER
133
ELEVATOR B
EL-B
ATRIUM
100A
CORR
100J
PATIO SEATING
P100
COLLABORATION
100F1
ATRIUM SEATING
100A4
C
D
E
F
H
J
7 8 9 10 11
9a'
D.01
D1
D2
7a 8a 9a9'6' 7' 8' 10' 11'9b9b'9a''
C.6
K
12
E.2
10.2 11.4 12.1
D.5
D.9
7
T-2.0
S102
MIC-1
SPK-1
SPK-1
SPK-1
SPK-1
S105
S104
S104
S104
S104
S103
SPK-2
SPK-2
S106
S106
PL
AN
NO
RT
H
TRUE N
ORTH
AU
DIO
/VIS
UA
L:
CH
EM
IST
RY
-P
HY
SIC
S R
EN
OV
AT
ION
Th
is D
raw
ing a
nd th
e D
esig
n s
how
n
there
on
are
th
e p
rope
rty o
f O
mni
Arc
hitects
. T
he r
ep
rodu
ction
, cop
yin
g
or
oth
er
use
of
this
Dra
win
g o
r D
esig
n
with
out th
e w
ritten
con
sen
t o
f O
mn
i A
rch
itects
is p
rohib
ite
d.
Job N
um
ber:
Le
xin
gto
n,
Ke
ntu
cky
212
No
rth U
pp
er
Str
ee
tL
exin
gto
n,
Ke
ntu
cky
405
07-1
00
1p
85
9.2
52
.666
4w
ww
.om
nia
rchitects
.co
m
Revis
ion:
BID DOCUMENTS
BID
DO
CU
ME
NT
S
T-1.1c
AU
DIO
/VIS
UA
L P
LA
N -
FIR
ST
FL
OO
RX
KC
P17-0
1M
AY
18, 2020TAGGED NOTES
S11 ROUTE FIBER UP THROUGH CHASE TO 1ST FLOOR.
S58 PROVIDE 2" CONDUIT ABOVE ACCESSIBLE CEILING SPACE,PROVIDE PULL BOXES AS REQUIRED. EXTEND 7-CAT6ACABLES FROM COMMUNICATIONS CLOSET 128 TO EXISTINGWIRELESS ACCESS POINTS IN CLASSROOMS AS REQUIRED.
S68 EXTEND A TEMPORARY FIBER SERVICE TO EXISTINGCOMMUNICATIONS CLOSET 128, ROUTE ON J-HOOKS ABOVEACCESSIBLE CEILINGS. PROVIDE PATCH PANEL ON WALL INEXISTING COMMUNICATIONS CLOSET 053. CABLING SHALLBE 6 STRANDS OF SINGLE MODE (FREEDOM CABLE) AND 6STRANDS OF OM1 MULTI MODE FIBER (FREEDOM CABLE ).
S89 EXTEND 1" CONDUIT SLEEVE THROUGH EXTERIOR WALL FOR5"X5"ANTENNA WITH ARTICULATING MOUNT (BY UK).
S102 VIDEO WALL EQUIPMENT FOR VIDEO WALL IN FIRST FLOORATRIUM TO BE LOCATED IN THIS ROOM. EQUIPMENT SHALLBE RACKED IN IT RACK IN CLOSE COORDINATION WITH UKITS.
S103 PROVIDE VIDEO WALL HERE, REFER TO DETAIL ON SHEETT-2.1.
S104 PROVIDE LOW PROFILE CEILING MOUNTED SPEAKER IN THISLOCATION. ROUTE SPEAKER CABLE TO VIDEO WALL RACK.
S105 PROVIDE XLR MICROPHONE INPUT WITH HDMI AND 3.5mmAUDIO WITH CABLING TO EQUIPMENT RACK.
S106 PROVIDE LINE ARRAY COLUMN LOUDSPEAKER (JBL CBT100LA-1) IN THIS LOCATION. ROUTE SPEAKER CABLE TOVIDEO WALL RACK. SEE SPECIFICATIONS FOR ADDITIONALINFORMATION.
T-1.1c 1/8" = 1'-0"
1 AUDIO/VISUAL - FIRST FLOOR - AREA C
Revision Schedule
No. Revision Date
4
C
A
21
E
B
D
A
1 2
B
C
D
E
3 4
A.90
D.01
A1
A2
D1
D2
4a1a 4b
C.6
3.9
D.5
D.9
4.8
FPD-5
FPD-6
FPD-7
COMPUTATIONAL LAB - KEKENES -HUSKY
341
SUPPLIES
376
CONFERENCE
378A
INSTRU LAB
350
LAB EQUIP
354
RESEARCH LAB - NEW HIRE #1
374
RESEARCH LAB - ODOM
370
RESEARCH LAB - GRAHAM
348
OFFICE
373
OFFICE
377
STUDENT WORKSTATIONS (12)
379
OFFICE
365
OFFICE
363
OFFICE
361
STUDENT WORKSTATIONS (4)
360
STUDENT WORKSTATIONS (10)
339
STAIR-B
ST-B
COLLABORATION AREA
300E1
COLLABORATION AREA
300C2
OFFICE
353
CUSTODIAL
340
TOILET
346
MEN
342
MDF
336B
WOMEN
344
TRASH/ RECYCLING
336
CONFERENCE
338
COLLABORATION AREA
300C3
OFFICE
375
OFFICE
359
OFFICE
357
MECHANICAL
369
ELEVATOR-A
EL-A
CHASE
PC4
CHASE
PC5
CONFERENCE
378B
RESEARCH LAB - KIM
372
STUDENT WORKSTATIONS (4)
371
ELECTRICAL
336A
STUDENT WORKSTATIONS (5)
345
STUDENT WORKSTATIONS (6)
347
OFFICE
349
CROSS CORRIDOR
300D
CORRIDOR NORTH
300E
STAIR-A
ST-A
CORRIDOR EAST
300F
CORRIDOR WEST
300C
STUDENT WORKSTATIONS (4)
355
OFFICE
351
COLLABORATION AREA
300F1
NORTH CAFE
337
FPD-7
FPD-7
FPD-5
FPD-6
FPD-6
FPD-7
FPD-7
FPD-7
A
1 2
B
C
D
E
3 4
A.90
D.01
A1
A2
D1
D2
4a1a 4b
C.6
3.9
D.5
D.9
4.8
S97
S97
S100
S100
S100
S99
S99
S98
S98
S98
S98
S98
S98
PL
AN
NO
RT
H
TRUE N
ORTH
AU
DIO
/VIS
UA
L:
CH
EM
IST
RY
-P
HY
SIC
S R
EN
OV
AT
ION
Th
is D
raw
ing a
nd th
e D
esig
n s
how
n
there
on
are
th
e p
rope
rty o
f O
mni
Arc
hitects
. T
he r
ep
rodu
ction
, cop
yin
g
or
oth
er
use
of
this
Dra
win
g o
r D
esig
n
with
out th
e w
ritten
con
sen
t o
f O
mn
i A
rch
itects
is p
rohib
ite
d.
Job N
um
ber:
Le
xin
gto
n,
Ke
ntu
cky
212
No
rth U
pp
er
Str
ee
tL
exin
gto
n,
Ke
ntu
cky
405
07-1
00
1p
85
9.2
52
.666
4w
ww
.om
nia
rchitects
.co
m
Revis
ion:
BID DOCUMENTS
BID
DO
CU
ME
NT
S
T-1.3a
AU
DIO
/VIS
UA
L P
LA
N -
TH
IRD
FL
OO
RX
KC
P17-0
1M
AY
18, 2020TAGGED NOTES
S97 IN THIS ROOM, PROVIDE INPUT LOCATION AT WALLOPPOSITE THE DISPLAY. REFER TO ELEVATIONS FORADDITIONAL INFORMATION.
S98 AUDIOVISUAL INTEGRATOR TO PROVIDE COLLABORATIONSYSTEM. REFER TO ELEVATION 2 ON SHEET T-2.0 ANDSCHEMATIC 1 ON SHEET T-2.1 FOR ADDITIONALINFORMATION.
S99 AUDIOVISUAL INTEGRATOR TO PROVIDE INTERACTIVEDIGITAL SIGNAGE DISPLAY. REFER TO ELEVATION 1 ONSHEET T-2.0 AND SCHEMATIC 2 ON SHEET T-2.1 FORADDITIONAL INFORMATION.
S100 AUDIOVISUAL INTEGRATOR TO PROVIDE CONFERENCEROOM PRESENTATION SYSTEM. REFER TO ELEVATION 5 ONSHEET T-2.0 AND SCHEMATIC 4 ON SHEET T-2.1 FORADDITIONAL INFORMATION.
T-1.3a 1/8" = 1'-0"
1 AUDIO/VISUAL - THIRD FLOOR - AREA A
Revision Schedule
No. Revision Date
9865
C
A
10 11
E
B
D
7
A
B
C
D
E
5 6 7 8 9 10 11
9a'
A.90
D.01
A1
A2
D1
D2
4b 5a 7a 8a 9a9'5' 6' 7' 8' 10' 11'9b9b' 10a
C.6
12
E.2
10.2 11.4 12.1
D.5
D.9
4.8 10.4
MECHANICAL
325
RESEARCH LAB - GUITON
380
RESEARCH LAB - NEW HIRE #2
334
RESEARCH LAB - NEW HIRE #3
332
SHARED BIOCHEM INSTR
388A
INSTRU
386
AUTOCLAVE
388B
RESEARCH LAB - HEIDARY
322RESEARCH LAB - GLAZER
318
RESEARCH LAB - WEI
390
RESEARCH LAB - AWUAH
310
TISSUE CULTURE
324B3
TISSUE CULTURE
324B1
TISSUE CULTURE PREPARATION
324B
RADIO-ISOTOPE LAB
324ACHEM PREP LAB
328
CYL ROOM
326
TISSUE CULTURE
324B2
STUDENT WORKSTATIONS (10)
381
OFFICE
383
OFFICE
385
OFFICE
387
STUDENT WORKSTATIONS (13)
389
OFFICE
391
OFFICE
393
STUDENT WORKSTATIONS (13)
395
FACULTY LOUNGE
397
STUDENT WORKSTATIONS (6)
305
OFFICE
307
OFFICE
309
OFFICE
313
OFFICE
315
STUDENT WORKSTATIONS (13)
319
STUDENT WORKSTATIONS (10)
333
SOUTH CAFE
301
COLLABORATION AREA
300F1
COLLABORATION AREA
300B1
COLLABORATION AREA
300B2
CONFERENCE
302
CUSTODIAL
398
LACTATION ROOM
392
WOMEN
394
MEN
396
OFFICE
331
OFFICE
327
CONFERENCE ROOM
303
EQUIPMENT CORRIDOR
388
COLLABORATION AREA
300C1
CHASE
PC3
CHASE
PC1
CHASE
PC2
CORRIDOR SOUTH
300B
OFFICE
321
OFFICE
323
COLLABORATION AREA
300F2
ELECTRICAL
306A
MDF
306B
OFFICE
311
NORTH CAFE
337
TRASH/ RECYCLE
306
RESEARCH LAB - RICHARDS
382C
RESEARCH LAB - RICHARDS
382B
RESEARCH LAB - RICHARDS
382A
RESEARCH LAB - RICHARDS
382
RESEARCH LAB - DEROUCHEY
384A
RESEARCH LAB - DEROUCHEY
384
OFFICE
329
RESEARCH LAB - WEI
390A
RESEARCH LAB - NEW HIRE #4
330
DW
DW1
SERVICE
399
EQUIPMENT CORRIDOR
324
STAIR-C
ST-C
SERVICE ELEVATOR
EL-C
STUDENT WORKSTATIONS (6)
317
ELEVATOR B
EL-B
TRASH/ RECYCLE
300C2
FPD-7
FPD-7
FPD-7
FPD-5
FPD-7
FPD-6
FPD-7
FPD-6
FPD-7
FPD-6
FPD-5
FPD-5
A
B
C
D
E
5 6 7 8 9 10 11
9a'
A.90
D.01
A1
A2
D1
D2
4b 5a 7a 8a 9a9'5' 6' 7' 8' 10' 11'9b9b' 10a
C.6
12
E.2
10.2 11.4 12.1
D.5
D.9
4.8 10.4
FPD-6
S98
S98
S98
S98
S98
S98
S99
S99
S99
S100
S100
S100
S101
PL
AN
NO
RT
H
TRUE N
ORTH
AU
DIO
/VIS
UA
L:
CH
EM
IST
RY
-P
HY
SIC
S R
EN
OV
AT
ION
Th
is D
raw
ing a
nd th
e D
esig
n s
how
n
there
on
are
th
e p
rope
rty o
f O
mni
Arc
hitects
. T
he r
ep
rodu
ction
, cop
yin
g
or
oth
er
use
of
this
Dra
win
g o
r D
esig
n
with
out th
e w
ritten
con
sen
t o
f O
mn
i A
rch
itects
is p
rohib
ite
d.
Job N
um
ber:
Le
xin
gto
n,
Ke
ntu
cky
212
No
rth U
pp
er
Str
ee
tL
exin
gto
n,
Ke
ntu
cky
405
07-1
00
1p
85
9.2
52
.666
4w
ww
.om
nia
rchitects
.co
m
Revis
ion:
BID DOCUMENTS
BID
DO
CU
ME
NT
S
T-1.3b
AU
DIO
/VIS
UA
L P
LA
N -
TH
IRD
FL
OO
RX
KC
P17-0
1M
AY
18, 2020
TAGGED NOTES
S98 AUDIOVISUAL INTEGRATOR TO PROVIDECOLLABORATION SYSTEM. REFER TOELEVATION 2 ON SHEET T-2.0 ANDSCHEMATIC 1 ON SHEET T-2.1 FORADDITIONAL INFORMATION.
S99 AUDIOVISUAL INTEGRATOR TO PROVIDEINTERACTIVE DIGITAL SIGNAGE DISPLAY.REFER TO ELEVATION 1 ON SHEET T-2.0 ANDSCHEMATIC 2 ON SHEET T-2.1 FORADDITIONAL INFORMATION.
S100 AUDIOVISUAL INTEGRATOR TO PROVIDECONFERENCE ROOM PRESENTATIONSYSTEM. REFER TO ELEVATION 5 ON SHEETT-2.0 AND SCHEMATIC 4 ON SHEET T-2.1 FORADDITIONAL INFORMATION.
S101 AUDIOVISUAL INTEGRATOR TO PROVIDECONFERENCE ROOM PRESENTATIONSYSTEM. REFER TO ELEVATION 3 ON SHEETT-2.0 FOR ADDITIONAL INFORMATION.
T-1.3b 1/8" = 1'-0"
1 AUDIO/VISUAL - THIRD FLOOR - AREA B
Revision Schedule
No. Revision Date
3' -
8"
FLOOR
FPD-55
3' -
11
"
9' -
0"
9'-0" CEILING
MONITOR MOUNT BY AV INTEGRATOR
CABLE ORGANIZATION
AND EQUIPMENT STORAGE BY AV
INTEGRATOR
AV WALL BOX BY OTHERS
5' -
2"
KORBYT DIGITAL SIGNAGE MEDIA
PLAYER TO BE INSTALLED ON
SLIDE-OUT SHELF
POWER AND DATA TO BE INSTALLED INSIDE THIS BOX
TOUCH SCREEN FLATPANEL DISPLAY - ELO
2
4' -
1 1
/4"
FLOOR
FPD-65
6' -
0"
4' -
3 1
/2"
9' -
0"
9'-0" CEILING
MONITOR MOUNT BY AV INTEGRATOR
CABLE ORGANIZATION AND EQUIPMENT STORAGE BY AV INTEGRATOR
AV WALL BOX BY OTHERS
HDMI INPUT ROUGHIN, EXISTING 6 X 6 X 3-1/2" BOX WITH SINGLE GANG EXTENSION RING
2" CONDUIT
1" CONDUIT
4' -
0"
1' -
6"
EXTRON SHARELINK PRO 500 TO BE INSTALLED ON SLIDE-OUT SHELF
POWER AND DATA TO BE INSTALLED INSIDE THIS BOX
7" CONTROL TOUCHPANEL BY AV INTEGRATOR, SINGLE GANG BOX ROUGH-IN IS EXISTING
2
2
4' -
1 1
/4"
FLOOR
FPD-65
6' -
0"
4' -
3 1
/2"
9' -
0"
9'-0" CEILING
AV WALL BOX BY OTHERS
2" CONDUIT
1" CONDUIT
4' -
0"
MONITOR MOUNT BY AV INTEGRATOR
CABLE ORGANIZATION AND EQUIPMENT STORAGE BY AV INTEGRATOR
HDMI INPUT ROUGHIN, EXISTING 6 X 6 X 3-1/2" BOX WITH SINGLE GANG EXTENSION RING
EXTRON SHARELINK PRO 500 TO BE INSTALLED ON SLIDE-OUT SHELF
POWER AND DATA TO BE INSTALLED INSIDE THIS BOX
LOCATION IS ACROSS THE ROOM. SEE FLOOR PLAN FOR ADDITIONAL INFORMATION.
7" CONTROL TOUCHPANEL BY AV INTEGRATOR, SINGLE GANG BOX ROUGH-IN IS EXISTING
2
2
5' -
0"
FLOOR
FPD-65
9'-0" CEILING
OFFSETTING AV WALL BOXES FOR BACK-TO-BACK DISPLAYS BY OTHERS
5' -
6"
9' -
0"
4' -
0"
1' -
6"
2" CONDUIT
1" CONDUIT7' -
0"
5' -
2"
MONITOR MOUNT BY AV INTEGRATOR
7" CONTROL TOUCHPANEL BY AV INTEGRATOR, SINGLE GANG BOX ROUGH-IN IS EXISTING
HDMI INPUT ROUGHIN, EXISTING 6 X 6 X 3-1/2" BOX WITH SINGLE GANG EXTENSION RING
EXTRON SHARELINK PRO 500 TO BE MOUNTED TO WALL BEHIND DISPLAY
POWER AND DATA TO BE INSTALLED INSIDE THIS BOX
2
2
2
5' -
0"
FLOOR
FPD-65
9' -
0"
9'-0" CEILING
AV WALL BOXBY OTHERS
5' -
6"
7' -
0"
5' -
2"
4' -
0"
1' -
6"
2" CONDUIT
1" CONDUIT
MONITOR MOUNT BY AV INTEGRATOR
HDMI INPUT ROUGHIN, EXISTING 6 X 6 X 3-1/2" BOX WITH SINGLE GANG EXTENSION RING
POWER AND DATA TO BE INSTALLED INSIDE THIS BOX
EXTRON SHARELINK PRO 500 TO BE MOUNTED TO WALL BEHIND DISPLAY
7" CONTROL TOUCHPANEL BY AV INTEGRATOR, SINGLE GANG BOX ROUGH-IN IS EXISTING
2
2
2
NOTES:1. J-BOX CENTERED AT LOCATION. SEE ELEVATIONS FOR EXACT DIMENSIONS.2. ALWAYS SPAN BETWEEN THREE STUDS.3. SEE PARTITION TYPES FOR STUD SIZE AND GAUGE.4. VERIFY LOCATIONS OF BACKING WITH PLANS & ROOM ELEVATIONS.5. FASTEN BACKING FLUSH WITH FACE OF STUDS.6. FLAT PANEL DISPLAYS AND MOUNTING BRACKETS BY AV CONTRACTOR.
METAL STUDS
BACKING SECTIONSSPAN AT LEAST 3 STUDS
TO SUPPORT 200 LBS+5X SAFETY FACTOR
(18"H X 48"W OVERALL MIN.)
CHIEF PAC525F WALL ENCLOSURE
POWER OUTLET
CUTOUT ANDWALL BOX
ASSEMBLY
CONCENTRIC (1/2", 1" AND 1-1/4") KNOCKOUTS
8' - 3 1/2"
4' -
5 7
/8"
9' - 11"
5' -
7"
PL
AN
NO
RT
H
TRUE N
ORTH
AU
DIO
/VIS
UA
L:
CH
EM
IST
RY
-P
HY
SIC
S R
EN
OV
AT
ION
Th
is D
raw
ing a
nd th
e D
esig
n s
how
n
there
on
are
th
e p
rope
rty o
f O
mni
Arc
hitects
. T
he r
ep
rodu
ction
, cop
yin
g
or
oth
er
use
of
this
Dra
win
g o
r D
esig
n
with
out th
e w
ritten
con
sen
t o
f O
mn
i A
rch
itects
is p
rohib
ite
d.
Job N
um
ber:
Le
xin
gto
n,
Ke
ntu
cky
212
No
rth U
pp
er
Str
ee
tL
exin
gto
n,
Ke
ntu
cky
405
07-1
00
1p
85
9.2
52
.666
4w
ww
.om
nia
rchitects
.co
m
Revis
ion:
BID DOCUMENTS
BID
DO
CU
ME
NT
S
T-2.0
AU
DIO
/VIS
UA
L D
ET
AIL
SX
KC
P17-0
1M
AY
18, 2020
T-2.0 NOT TO SCALE
1 AV DISPLAY ELEVATION FOR DIGITAL SIGNAGE/CORRIDORS
T-2.0 NOT TO SCALE
2 AV DISPLAY ELEVATION FOR COLLABORATION AREAS
T-2.0 NOT TO SCALE
3 AV DISPLAY ELEVATION FOR SOUTH CAFE ROOM 301
T-2.0 NOT TO SCALE
4 AV DISPLAY ELEVATION FOR BACK-TO-BACK CONFERENCE ROOMS
T-2.0 NOT TO SCALE
5 AV DISPLAY ELEVATION FOR NON BACK-TO-BACK CONFERENCE ROOMS
T-2.0 NOT TO SCALE
6 WALLBOX ROUGH-IN (CHIEF PAC525F)
FOR REFERENCE ONLY - PART OF EARLIER PACKAGE BY OTHERS
T-2.0 1/4" = 1'-0"
7 VIDEO WALL ELEVATION - BASE BID
T-2.0 1/4" = 1'-0"
8 VIDEO WALL ELEVATION - ALTERNATE
Revision Schedule
No. Revision Date
2 Chemistry/Physics Bid Package #2B Addendum 2
2020-07-02
HDMI
PASSIVE HDMI
TABLET
SMARTPHONE
LAPTOP
EXTRON SHARELINK PRO 500WIRED AND WIRELESSPRESENTATION GATEWAY
ETHERNET
PASSIVE HDMI/CEC
TCP/IPNETWORK
ROOM WIRELESS ACCESS POINT BY UK ITS
EXTRON WPD 110 APASS-THROUGH WALLPLATE
LAPTOP
LG UT640S0UA DISPLAY
EXTRON TLC PRO 726MTOUCHLINK PRO TOUCHPANELWITH BUILT IN CONTROLLER
INSTALL ON SLIDE-OUT SHELF BEHIND DISPLAY
RS232 TO DISPLAY
SHOWN FOR REFERENCE ONLY
COLLABORATION AREAS AND CAFE STATEMENT OF FUNCTIONALITY:
COLLABORATION AREAS SHALL BE CAPABLE OF WIRELESSLY SHARING CONTENT FROM ANY MOBILE DEVICE, WIRED AND WIRELESS SOURCES SHALL BE ABLE TO COLLABORATE SIMULTANEOUSLY, VIEW UP TO FOUR PIECES OF CONTENT SIMULTANEOUSLY.
WHEN SYSTEM IS NOT USED IT SHALL AUTOMATICALLY SWITCH TO DIGITAL SIGNAGE VIA RMG KORBYT ARIES PLAYER.
KORBYT ARIES MEDIA PLAYEROWNER FURNISHED, CONTRACTOR INSTALLED
HDMI
MOUNTED BEHIND DISPLAY
ETHERNET
3D IN WALLBOX(EXISTING)
PATCH CORD DATA DROP #2 IN WALLBOX
PATCH CORD TO DATA DROP #1 IN WALLBOX
PATCH CORD DATA DROP #3 IN WALLBOX
ELO 5553L 4K TOUCH SCREEN DISPLAY
KORBYT ARIES MEDIA PLAYEROWNER FURNISHED, CONTRACTOR INSTALLED
USB
HDMI
DATA DROP IN WALLBOX (EXISTING)
MOUNTED BEHIND DISPLAY
DIGITAL SIGNAGE STATEMENT OF FUNCTIONALITY:
DIGITAL SIGNAGE SYSTEM SHALL BE CABPABLE OF CONNECTION TO THE UNIVERSITY'S MANAGED SYSTEM (RMG KORBYT) VIA A STANDARD MEDIA PLAYER.
2
VIDEO WALL - 2X2 55"; 3840X2160; 0.88mm BEZEL TO BEZEL
CEILING MOUNTED LOUDSPEAKERS
AMPLIFIER
DSP
VIDEO WALL CONTROLLER AND PROCESSOR
ENCODER (QUANTITY 4)
EXTRON CONTROLLER
INPUT PLATE HDMI, XLR, 3.5mm AUDIO
VIDEO WALL AND ASSOCIATED AUDIO SYSTEM STATEMENT OF FUNCTIONALITY:
VIDEO WALL SYSTEM SHALL BE CAPABLE OF ONE IMAGE OR (4) IMAGES FROM (4) DIFFERENT SOURCES. VIDEO WALL CONTROLLER SHALL ACCOMODATE (4) SOURCES AND BE ABLE TO SCALE TO RESOLUTIONS NECESSARY.
AUDIO SUPPORT WILL CONSIST OF SPEAKERS IN THE SPACE WITH THE VIDEO WALL (REFER TO PLANS) INCLUDING WIRELESS MICROPHONE AND WIRED MICROPHONE CAPABILITY.
CONTROL SHALL CONSIST OF WIRELESS TOUCHPANEL ALONG WITH WIRED TOUCH PANEL LOCATED AT THE RACK. CONTROL SHALL BE BEHIND A PASSWORD PROTECTED INTERFACE.
95.52"
53.8
8"
EQUIPMENT TO BE LOCATED IN ITS RACK ROOM 128
LINE ARRAY SPEAKERS
DECODER (QUANTITY 4) ONE PER QUADRANT
WIRELESS MICROPHONE RECEIVER
TLP PRO 1025M MOUNTED ON RACK
2
HDMI
PASSIVE HDMI
TABLET
SMARTPHONE
LAPTOP
ETHERNET
EXTRON SHARELINK PRO 500WIRED AND WIRELESSPRESENTATION GATEWAY
ETHERNET
PASSIVE HDMI/CEC
TCP/IPNETWORK
ROOM WIRELESS ACCESS POINT BY UK ITS
EXTRON WPD 110 APASS-THROUGH WALLPLATE
LAPTOP
LG UT640S0UA DISPLAY
ETHERNET
3D IN WALLBOX(EXISTING)
PATCH CORD DATA DROP #2 IN WALLBOX
PATCH CORD TO DATA DROP #1 IN WALLBOX
INSTALL ON SLIDE-OUT SHELF BEHIND DISPLAY
HDMI
USB
LOGITECH MEETUP MOUNTED BELOW DISPLAY
OFE SMALL FORM FACTOR COMPUTER (BY UK ITS) MOUNTED BEHIND DISPLAY
EXTRON TLC PRO 726MTOUCHLINK PRO TOUCHPANELWITH BUILT IN CONTROLLER
RS232 TO DISPLAY
SHOWN FOR REFERENCE ONLY
CONFERENCE ROOM STATEMENT OF FUNCTIONALITY:
LOCAL CONTENT PRESENTATION MODE: THIS MODE WILL ALLOW THE ROOM TO BE CAPABLE OF WIRELESSLY SHARING CONTENT FROM ANY MOBILE DEVICE, WIRED AND WIRELESS SOURCES SHALL BE ABLE TO COLLABORATE SIMULTANEOUSLY, VIEW UP TO FOUR PIECES OF CONTENT SIMULTANEOUSLY.
OWNER FURNISHED COMPUTER MODE: THIS MODE WILL ALLOW THE USE OF THE UK ITS-ISSUED COMPUTER TO BE THE SOURCE FOR THE DISPLAY. THE COMPUTER WILL HAVE ACCESS TO THE ALL-IN-ONE CAMERA, MICROPHONE AND SPEAKER UNIT THAT IS TO BE MOUNTED BELOW THE DISPLAY.
PATCH CORD TO DATA DROP #3 IN WALLBOX
DIRECT VIEW LED VIDEO WALL - 1.58mm PIXEL PITCH, 1920X1080
AMPLIFIER
DSP
ENCODER (QUANTITY 4)
EXTRON CONTROLLER
DECODER (QUANTITY 4) ONE PER QUADRANT
VIDEO WALL AND ASSOCIATED AUDIO SYSTEM STATEMENT OF FUNCTIONALITY:
VIDEO WALL SYSTEM SHALL BE CAPABLE OF ONE IMAGE OR (4) IMAGES FROM (4) DIFFERENT SOURCES. VIDEO WALL CONTROLLER SHALL ACCOMODATE (4) SOURCES AND BE ABLE TO SCALE TO RESOLUTIONS NECESSARY.
AUDIO SUPPORT WILL CONSIST OF SPEAKERS IN THE SPACE WITH THE VIDEO WALL (REFER TO PLANS) INCLUDING WIRELESS MICROPHONE AND WIRED MICROPHONE CAPABILITY.
CONTROL SHALL CONSIST OF WIRELESS TOUCHPANEL ALONG WITH WIRED TOUCH PANEL LOCATED AT THE RACK. CONTROL SHALL BE BEHIND A PASSWORD PROTECTED INTERFACE.
119.04"
66.9
6"
EQUIPMENT TO BE LOCATED IN ITS RACK ROOM 128
CEILING MOUNTED LOUDSPEAKERS
LINE ARRAY SPEAKERS
VIDEO WALL CONTROLLER AND PROCESSOR
INPUT PLATE HDMI, XLR, 3.5mm AUDIO
WIRELESS MICROPHONE RECEIVER
TLP PRO 1025M MOUNTED ON RACK
2
PL
AN
NO
RT
H
TRUE N
ORTH
AU
DIO
/VIS
UA
L:
CH
EM
IST
RY
-P
HY
SIC
S R
EN
OV
AT
ION
Th
is D
raw
ing a
nd th
e D
esig
n s
how
n
there
on
are
th
e p
rope
rty o
f O
mni
Arc
hitects
. T
he r
ep
rodu
ction
, cop
yin
g
or
oth
er
use
of
this
Dra
win
g o
r D
esig
n
with
out th
e w
ritten
con
sen
t o
f O
mn
i A
rch
itects
is p
rohib
ite
d.
Job N
um
ber:
Le
xin
gto
n,
Ke
ntu
cky
212
No
rth U
pp
er
Str
ee
tL
exin
gto
n,
Ke
ntu
cky
405
07-1
00
1p
85
9.2
52
.666
4w
ww
.om
nia
rchitects
.co
m
Revis
ion:
BID DOCUMENTS
BID
DO
CU
ME
NT
S
T-2.1
AU
DIO
/VIS
UA
L S
CH
EM
AT
ICS
XK
CP
17-0
1M
AY
18, 2020
T-2.1 NOT TO SCALE
1 A/V SCHEMATIC FOR COLLABORATION AREAS AND CAFE
T-2.1 NOT TO SCALE
2 A/V SCHEMATIC FOR DIGITAL SIGNAGE
T-2.1 NOT TO SCALE
3 A/V SCHEMATIC FOR VIDEO WALL - BASE BID
T-2.1 NOT TO SCALE
4 A/V SCHEMATIC FOR CONFERENCE ROOMS
T-2.1 NOT TO SCALE
5 A/V SCHEMATIC FOR VIDEO WALL - ALTERNATE
Revision Schedule
No. Revision Date
2 Chemistry/Physics Bid Package #2B Addendum 2
2020-07-02