INTRODUCTIONThis interactive presentation aims to present viewers with sufficient knowledge about the revolutionary product for today’s fire fighting needs. Viewers will be equipped with knowledge regarding product characteristics, calculation, design, installations, approvals, feedback, etc., which is especially important for people who work in the technical field.
Viewers will be able to view videos, presentation, photos, specification, reports, links to websites, etc. just by clicking at the relevant icons/texts.
continue...
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
A revolution is taking place in Fire Suppression. Developed from solid rocket fuel technology,
Pyrogen is the world’s first commercially available Aerosol Fire Extinguishing System. Designed as a safe and practical alternative to
Halon, Pyrogen is available from stock in a wide range of canister sizes. The aerosol attacks the
fire chemically and physically, giving virtual instant extinguishment and preventing re-ignition.
For many applications, Pyrogen is the only practical alternative to Halon.
Click Logo to go to Pyrogen’s website
NextPrevious
SLIDE 1Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
Videos and Presentation
Movie Clip (AVI)
PyroRack Demo Video
Slides Presentation Pyrogen Pres
Click on the icons/texts below to view videos and presentation...
China Navy Demo Video
Product Presentation Video
NextPrevious
SLIDE 2Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Movie Clip (AVI)
Movie Clip (AVI)
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
Technical CharacteristicsCanister Characteristics
Canister Material : Marine Grade Aluminium Alloy (Mag-02 ~Mag-5) Industrial Grade Mild Steel (Mag-11 ~ Mag-17)
Surface Treatment : Enamel Coated (red)Max/Min Ambient : -50°C - +60°CShock : Tested at 10g for > 13,000 impactsVibration : 5g @ 50 - 250 HzCorrosion Resistance : Greater than UL 1058Impact Resistance : IP558Humidity : 96%
Electrical (Thermal ) Characteristics
Supervision/Monitoring Circuit : 1mAActivation (Electrical) : 400mA @6/12/24V for 10mSActivation (Thermal) : 175°CConnector : 4 pin Military Type 2PMDT
Analog MIL-C-5015
NextPrevious
SLIDE 3Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
Classifications
Classifications
Suitable for fire : Class A - Combustible Solids Class B - Flammable Liquids Class C - Flammable Gases Class E - Electrically Energised Fires
Handling & Transport : In accordance with UN 1325 & Dangerous Goods Class 4.1 Hazchem Code : 2[Y]E
Packaging Group : II
Click for Material Safety Data Sheet (MSDS)
NextPrevious
SLIDE 4Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
Design and SpecificationClick on the texts below to view Pyrogen System design requirements ...
Simplified design guide
Calculation
Typical layout drawing
Typical Input/Output Chart
Typical consultant specification
NextPrevious
SLIDE 5Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
Manuals
Industrial Design Manual V1.8For industrial applications
PyroRack ManualFor computer server applications
Fire Mermaid ManualFor marine applications
Click on the icons/texts below to view product manuals ...
PyroSense SP-1 ManualFor engine space and cnc machines applications
NextPrevious
SLIDE 6Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
Wide Ranges of ModelsFor small enclosure/in-cabinet...
MAG-1
400
60
0.6
mono
80
75
< 3
MAG-2
500
100
1
mono
95
75
< 5
MAG-3
700
200
2
mono
145
75
< 7
MAG-4
4,500
1,000
10
bi
350
95
< 10
MAG-5
1,830
500
5
mono
190
95
< 8
MAG-02
110
20
0.2
bi
120
25
< 2
Parameter
Mass of Generator g
Mass of AerosolForming Composition g
Max Protected Volume m3
@ 100 g/m3
Nozzle Outlet
Length mm
Diameter mm
Discharge Time sec
NextPrevious
SLIDE 7Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
Wide Ranges of ModelsFor big enclosure - wall/ceiling mounting...
MAG-12
14,500
2,200
17
mono
247
247
< 12
MAG-13
21,000
3,500
27
mono
235
306
< 15
MAG-14
28,000
6,000
46
mono
260
402
< 15
MAG-15
38,000
6,500
50
mono
175
492
< 15
MAG-11
12,000
1,500
12
mono
180
247
< 12
Parameter
Mass of Generator g
Mass of AerosolForming Composition g
Max Protected Volume m3
@ 100 g/m3
Nozzle Outlet
Length mm
Diameter mm
Discharge Time sec
NextPrevious
SLIDE 8Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
International Approvals
Bomba Malaysia
Pyrogen has gained acceptance worldwide. Click on the texts below to view Pyrogen’s approval from international bodies ...
NFPA 2010 - Standard For Fixed Aerosol Fire Extinguishing System
Scientific Services LaboratoryMaritime & CoastguardAgency
European Certification Bureau
Bureau Veritas
American Bureau of ShippingWork Cover Authority
Sydney Electricity
Royal Navy Lifeboat Institution (RNLI)
Waterways Authority
RINA Approval
And many more in our website ...
NextPrevious
SLIDE 9Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
Installation PhotosClick on the texts below for sample installation photos ...
General
In-cabinet
Vehicle system
Machinery
Pyrogen canisters are self contained, zero pressure units. As well as being light and safe to transport, they require no additional pipes, nozzles or distribution equipment. They cannot leak, burst or deteriorate.
Pyrogen canisters are electrically (or automatically thermally) activated. Simple wiring and plug-in connectors can reduce installation times to a third or less. If discharged, new canisters may be reinstalled in minutes affording minimal downtime and eliminate potentially hazardous periods of non-active fire suppression.
NextPrevious
SLIDE 10Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
BrochuresClick on the icons below to view product brochures ...
Pyrogen
PyroRackHandheld Unit
Pyrogen US
NextPrevious
SLIDE 11Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
Real Incident ReferencesClick on the texts below to view incident reports on fires, and how Pyrogen helped in minimising the damage ...
Singapore Police Coastguard
Finland Log Harvester
Finland Mercedes Bus
Anglo Gold South Africa
TauTona Anglo Gold South Africa
Port in Malaysia
NextPrevious
SLIDE 12Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
Test Reports
Brush Traction Report
Norway Bus System Test Report
Full Scale Air Craft EE Bay Test
Pyrogen has been independently tested by world distinguished bodies.Click on the texts below to view their test reports and evaluation ...
MCA Fire Test Report
Hong Kong Bus Fire Test Report
NextPrevious
SLIDE 13Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit
• Click to edit Master text styles– Second level
• Third level– Fourth level
» Fifth level
THANK YOU... FOR YOUR INTEREST IN ROCKET SCIENCE.
For even more information of our product, please contact our regional office nearest to you. Our contact details are: ASIAPYROGEN TECHNOLOGIES SDN. BHD.No. 2A, Jalan SS13/3D, Subang Jaya Industrial Estate, 47500 Subang Jaya, Selangor Darul Ehsan, Malaysia.Tel. : +603-5621 2211 Fax : +603-5621 5566 E-mail : [email protected]
EUROPEPYROGEN LTD.Gilnow Mill Business Centre, Spa Road,Bolton BL1 4LF, United Kingdom.Tel. : +44(0) 1204 373300 Fax : +44(0) 1204 373355 E-mail : [email protected]
AUSTRALIA/NEW ZEALANDPYROGEN PTY. LTD.18, Barry Avenue, Mortdale,NSW 2223, Australia.Tel. : +612-9586 3200 Fax : +612-9586 3211 E-mail : [email protected]
THE AMERICASFIREPAK OIL AND GAS INDUSTRIES IlC7171 Harwin Dr, Suite 316, Houston, Texas 77036Tel. : +713-952 1996 Fax : +713-952 1997E-mail : [email protected]
Back to TopPrevious
SLIDE 14Slides
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Go to
Exit