intrepid control systems, inc. neo vi blue · pdf fileintrepid control systems, inc. ......

2
INTREPID CONTROL SYSTEMS, INC. Intrepid Control Systems, Inc. 31601 Research Park Drive Madison Heights, MI 48071 USA (ph) +1-586-731-7950 (fax) +1-586-731-2274 www.intrepidcs.com Rev.08052011 The Multi-Purpose Hardware Tool for Vehicle Networks Intrepid Control Systems introduces neoVI, the new vehicle interface for your PC that fits in your pocket. The neoVI vehicle to PC interface is designed to be easy to install and use. Receiving and transmitting data on your network is hassle free. Unprecedented Software Support Software support for the neoVI is outstanding. You can build your own applications or use off-the-shelf software to get started immediately. The Vehicle Spy and Vehiclescape products provide a turn-key solution. The free RAW API and WIN32 DLLs allow fast development in languages such as Visual Basic, Visual C++, C# .NET and LabVIEW. Network Protocols of Today and Tomorrow - Simultaneously neoVI can perform simultaneous reception and transmission on six different networks. This includes two dual wire CAN networks, one single wire CAN network, a Class 2 compatible J1850 VPW network, a Ford SCP compatible J1850 PWM network, and a ISO9141/Keyword 2000 network. Each network message is time stamped to a 100 μs clock. Also, neoVI is compatible with the GMLAN messaging strategy, OBD-II, LIN, and the J1939 truck and bus messaging strategy. Flexible Interfaces to the PC with Two Choices neoVI is an external device which can be used on both laptops and desktops -unlike competitive solutions with PCMCIA and PCI interfaces. It implements a RS232 interface for simple connection with low speed protocols and a high speed USB connection for both low and high speed protocols. neo VI BLUE Multi-Protocol Vehicle Interface

Upload: hakhuong

Post on 23-Feb-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

INTREPID CONTROL SYSTEMS, INC.

Intrepid Control Systems, Inc.31601 Research Park Drive Madison Heights, MI 48071 USA (ph) +1-586-731-7950 (fax) +1-586-731-2274

www.intrepidcs.comRev.08052011

The Multi-Purpose Hardware Tool for Vehicle Networks

Intrepid Control Systems introduces neoVI, the new vehicle interface for your PC that fits in your pocket. The neoVI vehicle to PC interface is designed to be easy to install and use. Receiving and transmitting data on your network is hassle free.

Unprecedented Software Support

Software support for the neoVI is outstanding. You can build your own applications or use off-the-shelf software to get started immediately. The Vehicle Spy and Vehiclescape products provide a turn-key solution. The free RAW API and WIN32 DLLs allow fast development in languages such as Visual Basic, Visual C++, C# .NET and LabVIEW.

Network Protocols of Today and Tomorrow - Simultaneously

neoVI can perform simultaneous reception and transmission on six different networks. This includes two dual wire CAN networks, one single wire CAN network, a Class 2 compatible J1850 VPW network, a Ford SCP compatible J1850 PWM network, and a ISO9141/Keyword 2000 network. Each network message is time stamped to a 100 µs clock. Also, neoVI is compatible with the GMLAN messaging strategy, OBD-II, LIN, and the J1939 truck and bus messaging strategy.

Flexible Interfaces to the PC with Two Choices

neoVI is an external device which can be used on both laptops and desktops -unlike competitive solutions with PCMCIA and PCI interfaces. It implements a RS232 interface for simple connection with low speed protocols and a high speed USB connection for both low and high speed protocols.

neo VI BLUE

Multi-ProtocolVehicle

Interface

Intrepid Control Systems, Inc.31601 Research Park Drive Madison Heights, MI 48071 USA (ph) +1-586-731-7950 (fax) +1-586-731-2274

www.intrepidcs.comRev.08052011

neo VI BLUE neoVI is Designed for Automated Test neoVI has built-in support for automated test. It is equipped with generic IO that can be configured to trigger a digital scope or data acquisition system. neoVI implements a DAQ clock feature which generates a start scan and scan clock for a data acquisition card. This allows correlation of network messages and DAQ card data to 100 µs. Finally, the firmware can be updated via the RS232 or USB port, even during a test script! This allows specialized real-time firmware to be temporarily loaded into the device and executed.

neoVI is a Smart Interface for a Data Logger Built for industrial temperature range, neoVI is perfect as a front-end for a flight recorder or data logger. Each sub circuit on neoVI implements micro-amp power down modes. The device can wake up on activity of any network, connection of USB, and connection/signaling on RS232.Device Specifications* Power Consumption (typical) : 120mA @ 14.4 VDC * Power Supply: vehicle compatible 4.5-32.0 VDC* Physical Dimensions : 120 x 70 x 25 mm ( 4.8 " x 2.8 " x 1.0" )* Weight: 113 g ( 4 oz )* Non USB Temperature Range: -40 to 85 C* USB Temperature Range: 0 to 70 C * Vehicle Connector : 25 Pin male D-SUB* Standard PC/Host Connectors: USB downstream, RS232 9PIN D-SUB Female* RS232 port capable of 115.2 kb, 57.6 kb, 38.4 kb, 28.8 kb, 19.2 kb, 9600 bps, and 4800 bps baud rates. Control lines include hardware handshaking

(RTS/CTS).* Warranty: One year limited warranty* Firmware: Field upgradeable design (flash EEPROM)* On board Processing: 16 MIPS RISC based multi-controller design* Bicolor user notification LED (red-green) is user configurable or can change on network activity, trigger or IO pin.* General Purpose IO: Six IO configurable as input or output. Four configurable as 10 bit analog inputs. One configurable for external wakeup. ISO

K and L Lines available as general purpose outputs. K Line available is general purpose input. * General Purpose IO rate report interval 1-100 ms or based on digital change. Analog input sampling rate is 1 ms per channel.

Networks - General* Time stamping to accuracy of 100uS on CAN networks, J1708 network, and Ford SCP network. 250 µs on Class 2 / J1850 VPW and ISO/KW2K.

Timestamp rollover is greater than 1 year.* Simultaneous operations on all networks with aggregate bandwidth performance of 2 mega baud over USB.* Transmit message double-buffering on all networks allows back to back message transmission.* Multiple hardware triggers allow bit-wise filter specifications on entire message (first 12 bytes for block type messages)* Generation of scan clock with correlated start message timestamp for synchronization of external data acquisition equipment

High Speed CAN* ISO11898 Dual Wire CAN Physical Layer (TJA1050)* CAN 2.0B active* MCP2510 CAN controller with support for loop-back and listen-only operation.* Optimized Rx and Tx circuitry* Up to 1 M-Bit software selectable baud rate* Graphical Bit Time/Baud Rate Calculator Medium Speed CAN* ISO11898 Dual Wire CAN Physical Layer (TJA1050)* CAN 2.0B active* MCP2510 CAN controller with support for loop-back and listen-only operation.* Up to 1 M-Bit software selectable baud rate* Graphical Bit Time/Baud Rate Calculator Low Speed Fault Tolerant CAN* ISO11519 Low Speed Fault Tolerant CAN Physical Layer (TJA1054)* CAN 2.0B active* MCP2510 CAN controller with support for loop-back and listen-only operation.* Software selectable baud rate/bit timing up to limitations of physical layer.* Graphical Bit Time/Baud Rate Calculator* Termination resistor in sockets for customization of network impedance Single Wire CAN* Single Wire CAN physical layer GMW3089/ SAE J2411 (MC33897D)* CAN 2.0B active* MCP2510 CAN controller with support for loop-back and listen-only operation.* High Speed Mode and High Voltage Wakeup support* Software selectable baud rate/bit timing up to limitations of physical layer.* Graphical Bit Time/Baud Rate Calculator

GM Class 2/ SAE J1850 VPW* VPW Physical Layer capable of Tx and Rx operations in high speed modes (MC33390)* Software controlled peripheral based VPW generation* Software modifiable bit timing acceptance parameters* Software modifiable bit timing generation parameters* Trigger generation based on network error or lost arbitration event* Reception of IFR data during rx and tx UART/ISO9141/Keyword 2000 (ISO14230)/ LIN Bus (Local Interconnect Network)* K and L lines implemented

* Initialization waveforms including Fast Init, Five Baud, CARB and Custom* Programmable timing parameters including inter-byte, TX inter-frame, RX inter-frame and initialization waveforms (0.5 ms resolution)* Software selectable baud rate* Socket selectable pull up resistor on both K and L lines* Jumper selectable pull up voltage either 5V or Battery* K and L have software controlled transmit enable lines allowing many different variants of UART or ISO9141 communications including: Tx on L Rx on K (full duplex); Tx and Rx on K (half duplex); Tx on K and L and Rx on K* LIN Bus Monitor Mode identifies errors : Sync Break Error State and Length, Sync Wave Error, Message ID parity, TFrameMax/Slave Not Responding, Checksum Error and Transmit Bit Errors.* LIN Bus Master Mode operates at same time as LIN Bus monitor Ford SCP/ SAE J1850 PWM (setup image)* Software setup of LBCC including the Node Address, Lookup Table 1 and 2, and the Network Driver and Receive Control Register* Software selectable SCP bit rate of 41.6 kbps or 83.3 kbps SAE J1708* SAE J1708 Physical Layer* Software setup of SAE J1708 parameters* Receive Only Support