INTERNATIONAL PRODUCT & SERVICES CATALOG
34ELECTROPHYSIOLOGY
3
Table of Contents
Bard Electrophysiology Greeting 3
Ablation Catheters, Cables, and System 5-20 EASYCOOLTM Irrigated Tip Ablation Catheter 5-6
SCORPIONTM 2 Catheter 7-8
STINGERTM Catheter 9-15
BARD® HD Mesh Ablator System 17-18
BARD® RF Cardiac Ablation Generator 19-20
Diagnostic and Mapping Catheters and CablesAdvanced Mapping 21-24 BARD® HD MESH MAPPERTM Catheter 21-22
ORBITERTM PVTM Catheter 23-24
Steerable 25-32 RADIATM XT Catheter 27
EP•XTTM Catheter 28-29
DYNAMIC TIPTM Catheter 30
DYNAMIC XTTM Catheter 31-32
Fixed Curve 33-54 Woven Catheter 34-44
WOVENFLEXIETM Catheter 45
VIKINGTM Catheter 46-50
VIKING SOFT TIPTM Catheter 51-52
TANGOTM Catheter 53-54
Atrial Mapping 55-59 RADIATM Bidirectional Diagnostic Catheter 56
ORBITERTM STTM Catheter 57
ORBITERTM Catheter 58-59
Specials Program 61
Intracardiac Access Products 63-71DIREXTM Steerable Sheath 63-64
EZCROSSTM Introducer Kit 65-66
SAFESHEATH® Ultra Introducer 67-68
BARD® CHANNELTM Steerable Sheath 69-70
TSXTM Transseptal Needles 71
Temporary Pacing Electrodes 73 NBIHTM & GOETZTM Bipolar 74
NBIHTM & GOETZTM Soft Tip Bipolar 75
Semi-Floating & Special Care 76
Balloon Bipolar 77
ZUCKERTM & MYLERTM Lumen 78
CVP & GORLINTM 79
EP SystemsEP Recording System 81-86 LABSYSTEMTM PRO EP Recording System 81
LabLink Data Interface 81
EPLOGIXTM Mapping and Analysis Suite 82
CLEARSIGNTM Amplifier 82
EP Review Workstation 83
Report Generator 83
EPLINKTM H.I.S. Interface Software 83
Cardiac Stimulator 87-90 MicroPace STIMLABTM 87
STIMCORTM 87
MicroPace EPS320 87
MicroPace Touch Screen Interface 88
Equipment Protection 91-92 Warranty 91
Extended Service Portfolio 91
– Presidential
– Executive
– Partnership
Customer ServiceServices 93-95 Contact Information 93
Delivery 93
Limited Product Warranty 94
Return Goods Policy 94
Complaints 95
Disclaimer 95
Index 97-100
1
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Before use, consult product labels and inserts for any indications, contraindications, hazards, warnings, cautions and instruction for use.
2
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Bard Electrophysiology History/Intro
Dear Valued Customer,
Thank you for your business and continued support of Bard Electrophysiology products.
We are happy to provide you with this new product and services catalog and take pride
in being your trusted EP partner.
With a history of commitment to quality products and services and many years of experience
focusing on electrophysiology, we continue to develop products for users, by collaborating with
physicians around the world. From diagnostic and therapeutic catheters and accessories to
recording systems and cardiac stimulators, Bard Electrophysiology offers a full range of solutions.
We, at Bard Electrophysiology, are focused on delivering advanced health care solutions by
developing, manufacturing and marketing value-driven products for the customers and patients
we serve. In addition, we are dedicated to creating a global educational environment to enrich
the field of electrophysiology.
This catalog contains products and services developed with the quality, integrity, service, and
innovation you have come to count on with Bard Electrophysiology. You can expect consistent
support and service from our customer representatives here to help you everyday.
We look forward to working with you and providing you with new EP solutions.
Sincerely,
Kevin Kelly
Vice President and General Manager
C.R. Bard, Inc.
Bard Electrophysiology Division
3
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
4
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
5
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Ablation Catheters, Cables, and System
EASYCOOLTM Irrigated Tip Ablation Catheter
The EASYCOOL™ Irrigated Tip Ablation Catheter has a 360° push-pull ergonomic handle design for steering and comfort.
• Convective electrode cooling
• Gold tip ablation electrodes
• Two rings of six holes
Thermal Conductivity
AblationCatheters,Cables, and System
6
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Ablation Catheters, Cables, and System
• Effective catheter length: 100cm • Diameter of catheter: 7F (2.33mm) • Number of electrodes: 4
• Electrode spacing: 2/5/2mm • Electrode length: 2mm (ring); 4mm (tip) • Electrode material: Gold (G)
• Temperature sensor: Thermocouple • Recommended guiding-catheter: 8 F min (2.67mm min)
• Applicable power: Unipolare application: 75 Watt maximum • Resistance: < 5 Ohm
• Insulation material: PEBAX/PU • Operating temperature: 30-80°C • Accuracy: ± 2°C
• Connector: 9-polar REDEL connector • Irrigation connector: LUER female
EASYCOOLTM IRRIGATED TIP ABLATION CATHETER
EASYCOOLTM ABLATION CATHETER CONNECTOR CABLE
Catalog Flexible Distal Curve Number Length Type
105327 S (60mm) Small 105229 M (70mm) Medium 105247 L (80mm) Large 105265 XL (90mm) Extra-Large
Catalog Generator Number Description Compatibility
100016 EASYCOOLTM A Cable Atakr 100323 EASYCOOLTM B Cable Bard 100015 EASYCOOLTM E Cable EP-Shuttle 100014 EASYCOOLTM H Cable Hat 300 Osypka 100013 EASYCOOLTM I Cable IBI-1500T11
• Usable length: 250cm
• Packing: Box with 1 sterile
cable in Stericlin-pouch
EASYCOOLTM ABLATION CATHETER TUBING SETCatalog Number Description Pump
103050 EASYCOOLTM CR Tubing Set COOLFLOWTM
• Usable length: 280cm
• Packaging: Box with 1 sterile
tubing set in Stericlin-pouch
Ablation Catheters, Cables, and System
SCORPIONTM 2 ABLATION CATHETER FAMILYPerfect Curves for Endless Possibilities
The SCORPIONTM 2 ablation catheter offers a differentiated dual curve configuration with a bi-directional distal tip. Both the proximal and distal curves work in conjunction to enable rapid achievement of optimal tip orientation and tissue contact bringing ease and efficiency to theablation procedure.
Proximal and distal curve formation with a single hand enhances efficiency and precision.
Patented CURVELOCKTM technology automatically prevents unwanted curve movement to reduce fatigue.
Bi-directional tip expands curve radius, reducing need for catheter exchange and improving procedural efficiency.
Coverage of minimum curve radius of 24mm to a maximum reach of 69mm with only three curves – medium, large, and extra large – reduces inventory requirements.
Bi-directional distal tip facilitates optimal orientation, even in difficult anatomy.
Improved endocardial tissue contact provides the high fidelity mapping and precise RF energy delivery.
Single-handedDual Controls
UnparalleledCurve
Versatility
Optimal Tip Orientation
7
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
AblationCatheters,Cables, and System
• Packaged straight • Single use only • Items per
box: 1 • Supplied sterile • Number of electrodes:
quadpolar • Electrode spacing: 2, 5, 2mm
• Proximal electrodes: 1mm • Usable length: 105cm
• Available with Thermistor or Thermocouple Temperature Sensing
8F/7F
SCORPIONTM 2 ABLATION CATHETER FAMILY
SCORPIONTM 2 COMPATIBLE TEMPLINKTM CABLES
Ablation Catheters, Cables, and System
8
Contact Your Local Representative for Product Availability: 1-800-824-8724
Catalog Tip/Shaft Distal Temp Curve Curve Tip Maximum Number French Size Electrode Sensor Type Radius Length Reach
310001T 7F/7F 4mm TM Medium 35mm 68mm 54mm 310002T 7F/7F 4mm TM Large 40mm 78mm 64mm 310003T 7F/7F 4mm TM Extra Large 50mm 90mm 68mm 310010T 7F/7F 4mm TC Medium 35mm 68mm 54mm 310011T 7F/7F 4mm TC Large 40mm 78mm 64mm 310012T 7F/7F 4mm TC Extra Large 50mm 90mm 68mm
310004T 8F/7F 5mm TM Medium 35mm 69mm 55mm 310005T 8F/7F 5mm TM Large 40mm 79mm 65mm 310006T 8F/7F 5mm TM Extra Large 50mm 91mm 69mm 310013T 8F/7F 5mm TC Medium 35mm 69mm 55mm 310014T 8F/7F 5mm TC Large 40mm 79mm 65mm 310015T 8F/7F 5mm TC Extra Large 50mm 91mm 69mm310019T 8F/7F 8mm TM Medium 35mm 72mm 58mm310020T 8F/7F 8mm TM Large 40mm 82mm 68mm310021T 8F/7F 8mm TM Extra Large 50mm 94mm 72mm310023T 8F/7F 8mm TC Large 40mm 82mm 68mm310024T 8F/7F 8mm TC Extra Large 50mm 94mm 72mm
TM = Thermistor, TC = Thermocouple
Products Not Approved or Available in All Geographies.
Medium Large Extra Large
Reusable via 3X EO, 10X STERRADTM or AutoclaveCatalog RF Generator Connection to RF UsableNumber Compatibility Generator Systems Length
210055A BIOSENSEWEBSTER® Stockert 70W or 100W Direct Connection 300cm210057A Boston Scientific EPT-1000TC, EPT-1000XPTM (821/822T model) Direct Connection 300cm210078MA MEDTRONICTM Atakr Direct Connection 210cm210079A IBI RF Generator Series Direct Connection 300cm
Reusable via 3X EO210055 BIOSENSEWEBSTER® Stockert 70W or 100W Direct Connection 300cm210057 Boston Scientific EPT-1000TC, EPT-1000XPTM (821/822T model) Direct Connection 300cm210078M MEDTRONICTM Atakr Direct Connection 210cm
DistalElectrode A B
4mm 25mm 45mm 5mm 24mm 46mm
Medium Curve
DistalElectrode A B
4mm 30mm 50mm 5mm 29mm 51mm
Large Curve
DistalElectrode A B
4mm 40mm 60mm 5mm 39mm 61mm
Extra Large Curve
• All cables supplied sterile
• Items per box: 1
Ablation Catheters, Cables, and System
STINGERTM ABLATION CATHETER FAMILYEndocardial Ablation with Advanced Placement and Control
Available in 4mm, 5mm and 8mm distal tips, the STINGERTM ablation catheter is offered in four versions to meet different torque and compatibility needs. For precise positioning and control, the STINGERTM product line offers a unique blend of technology and ergonomics, allowing physicians to negotiate challenging anatomy with confidence and speed.
Shaft-to-tip dissociation and bidirectional curve actuation enable accurate and precise catheter placement. Patented CURVELOCKTM Mechanism locks the curve into place, preventing movement once the target is reached.
Many catheter electrodes have an adhesive overcoat on their edges that can distort or degrade signal quality. The STINGERTM ablation catheter has compression-fit electrodes, with no adhesive overcoat, which allows complete contact with the tissue.
To meet your particular needs and preferences, the STINGERTM ablation catheterfamily is available in a wide range of curves as well as two tip stiffnesses. Each of these two shaft styles is available in either Thermocouple or Thermistortemperature sensing compatibility.
Provides the highest levels of stability and precision, enabling faster proceduresand better patient outcomes.
Offers compatibility with the MEDTRONICTM Atakr RF Generator, and Thermocouple temperature sensing technology.
Provides greater lateral distal tip support in those anatomies where a firmer tipis required.
Provides both greater lateral distal tip support as well as compatibility with theMEDTRONICTM Atakr RF Generator.
Advanced Placement
Maximum Tissue
Contact
Range of Configurations
STINGERTM
Standard
STINGERTM M
STINGERTM S
STINGERTM SM
9
Contact Your Local Representative for Product Availability: 1-800-824-8724
AblationCatheters,Cables, and System
Products Not Approved or Available in All Geographies.
A Yellow B Red
• Packaged coiled • Single use only • Items per box: 1
• Supplied sterile • Number of electrodes: quadpolar
• Electrode spacing: 2,5,2mm • Usable length: 115cm
• Thermistor Temperature Sensor
8F/7F
STINGERTM ABLATION CATHETER(STABILITY AND PRECISION)
Ablation Catheters, Cables, and System
C Green D Blue E White F Orange G Grey
Catalog Tip/Shaft Distal Curve Number French Size Electrode Type Color
210001 7F 4mm A Yellow 210002 7F 4mm B Red 210003 7F 4mm C Green 210004 7F 4mm D Blue 210005 7F 4mm E White 210006 7F 4mm F Orange 210007 7F 4mm G Grey
210025 8F/7F 5mm C Green 210026 8F/7F 5mm D Blue 210027 8F/7F 5mm E White 210028 8F/7F 5mm F Orange 210029 8F/7F 5mm G Grey
210016 7F 8mm B Red 210018 7F 8mm D Blue 210019 7F 8mm E White 210020 7F 8mm F Orange 210030 7F 8mm G GreySee Cable Reference Section for detail
10
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Tip/Shaft Distal Curve Number French Size Electrode Type Color
210001M 7F 4mm A Yellow 210002M 7F 4mm B Red 210003M 7F 4mm C Green 210004M 7F 4mm D Blue 210005M 7F 4mm E White 210006M 7F 4mm F Orange 210007M 7F 4mm G Grey
210025M 8F/7F 5mm C Green 210026M 8F/7F 5mm D Blue 210027M 8F/7F 5mm E White 210028M 8F/7F 5mm F Orange 210029M 8F/7F 5mm G Grey
210016M 7F 8mm B Red 210018M 7F 8mm D Blue 210019M 7F 8mm E White 210020M 7F 8mm F Orange 210030M 7F 8mm G Grey See Cable Reference Section for detail
8F/7F
STINGERTM M ABLATION CATHETER(COMPATIBLE WITH MEDTRONICTM ATAKR GENERATOR)
Ablation Catheters, Cables, and System
AblationCatheters,Cables, and System
A Yellow B Red C Green D Blue E White F Orange G Grey
11
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
• Packaged coiled • Single use only • Items per box: 1
• Supplied sterile • Number of electrodes: quadpolar
• Electrode spacing: 2,5,2mm • Usable length: 115cm
• Thermocouple Temperature Sensor
Catalog Tip/Shaft Distal CurveNumber French Size Electrode Type Color
210001S 7F 4mm A Yellow 210002S 7F 4mm B Red 210003S 7F 4mm C Green 210004S 7F 4mm D Blue 210005S 7F 4mm E White 210006S 7F 4mm F Orange 210007S 7F 4mm G Grey
210025S 8F/7F 5mm C Green 210026S 8F/7F 5mm D Blue 210027S 8F/7F 5mm E White 210028S 8F/7F 5mm F Orange 210029S 8F/7F 5mm G Grey
210016S 7F 8mm B Red 210017S 7F 8mm C Green210018S 7F 8mm D Blue 210019S 7F 8mm E White 210020S 7F 8mm F Orange 210030S 7F 8mm G Grey
218501S 7F 4mm A Yellow218502S 7F 4mm B Red218503S 7F 4mm C Green218504S 7F 4mm D Blue218505S 7F 4mm E White218506S 7F 4mm F Orange218507S 7F 4mm G GreySee Cable Reference Section for detail
• Packaged coiled • Single use only • Items per box: 1
• Supplied sterile • Number of electrodes: quadpolar
• Electrode spacing: 2,5,2mm • Usable length: 115cm
and 85cm • Thermistor Temperature Sensor
8F/7F
STINGERTM S ABLATION CATHETER(FIRMER TIP SEGMENT)
Ablation Catheters, Cables, and System
12
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
A Yellow B Red C Green D Blue E White F Orange G Grey
Catalog Tip/Shaft Distal Curve Number French Size Electrode Type Color
210001SM 7F 4mm A Yellow 210002SM 7F 4mm B Red 210003SM 7F 4mm C Green 210004SM 7F 4mm D Blue 210005SM 7F 4mm E White 210006SM 7F 4mm F Orange 210007SM 7F 4mm G Grey
210025SM 8F/7F 5mm C Green 210026SM 8F/7F 5mm D Blue 210027SM 8F/7F 5mm E White 210028SM 8F/7F 5mm F Orange 210029SM 8F/7F 5mm G Grey
210016SM 7F 8mm B Red 210018SM 7F 8mm D Blue 210019SM 7F 8mm E White 210020SM 7F 8mm F Orange 210030SM 7F 8mm G Grey
218501SM 7F 4mm A Yellow218502SM 7F 4mm B Red218503SM 7F 4mm C Green218504SM 7F 4mm D Blue218505SM 7F 4mm E White218506SM 7F 4mm F Orange218507SM 7F 4mm G GreySee Cable Reference Section for detail
• Packaged coiled • Single use only • Items per box: 1
• Supplied sterile • Number of electrodes: quadpolar
• Electrode spacing: 2,5,2,mm • Usable length: 115cm
and 85cm • Thermocouple Temperature Sensor
8F/7F
STINGERTM SM ABLATION CATHETER(FIRMER TIP SEGMENT AND COMPATIBLE WITH MEDTRONICTM ATAKR GENERATOR)
Ablation Catheters, Cables, and System
AblationCatheters,Cables, and System
13
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
A Yellow B Red C Green D Blue E White F Orange G Grey
14
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Ablation Catheters, Cables, and System
TEMPLINKTM CABLES FOR STINGERTMABLATION CATHETERS • All cables supplied sterile • Items per box: 1
Reusable via 3X EO, 10X STERRADTM or AutoclaveCatalog RF Generator Connection to RF UsableNumber Compatibility Generator Systems Length
210055A BIOSENSEWEBSTER® Stockert 70W or 100W Direct Connection 300cm210057A Boston Scientific EPT-1000TC, EPT-1000XPTM (821/822T model) Direct Connection 300cm210078MA MEDTRONICTM Atakr Direct Connection 210cm210079A IBI RF Generator Series Direct Connection 300cm
Reusable via 3X EO210055 BIOSENSEWEBSTER® Stockert 70W or 100W Direct Connection 300cm210057 Boston Scientific EPT-1000TC, EPT-1000XPTM (821/822T model) Direct Connection 300cm210078M MEDTRONICTM Atakr Direct Connection 210cm
15
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Curve C
Curve F Curve G
Curve D
Curve B
Curve E
Curve A
STINGERTM ABLATION CATHETER FAMILY CURVE SELECTION CHART
Ablation Catheters, Cables, and System
AblationCatheters,Cables, and System
16
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Ablation Catheters, Cables, and System
BARD® HD MESH ABLATOR SYSTEMA New Way
The BARD® HD Mesh Ablator Catheter is built around proprietary mesh geometry that optimizes contact and signal quality without obstructing blood flow. The variable 3D geometry and 36 electrode designadapts to a multitude of anatomies and provides high density spacing and discriminating electrograms. Unlike conventionalablation catheters that deliver point-to-point lesions, theBARD® HD Mesh Ablator Catheter delivers energy simultaneously to multiple electrodes which may contribute to faster lesion creation†. The exclusive mesh disc is heparin coated.
†Data on file.
Optimal Contact Yields a Better Signal
17
Contact Your Local Representative for Product Availability: 1-800-824-8724
AblationCatheters,Cables, and System
Products Not Approved or Available in All Geographies.
BARD® CHANNELTM
Steerable Sheath
A Complete Procedural Solution
BARD® TSXTM
Transseptal NeedleBARD® HD Mesh Ablator Catheter
BARD® TEMPULSETM
Pulsed RF Controller
Catalog No. of Usable Number Electrodes Diameter Length
410002 36 30mm 112cm
Catalog Number Description
330051A Mesh Ablator Extension Cable Kit (Reusable 3X EO/10X STERRADTM/Autoclave)
Catalog Number Description
Tempulse Pulsed RF Controller340003 TEMPULSETM Controller
BARD® Tempulse Pulsed RF Controller Cables340013 TEMPULSETM Dual Patient Reference Cable330053 Stockert Generator Power Cable330056 Stockert Reference Cable330058 STAMPTM IECG Cable330059 CLEARSIGNTM IECG Cable330060 Universal IECG Cable330062 BARD® Generator Power Cable330063 BARD® Generator Reference Cable330061 NAVXTM Cable
Catalog Number Description
XD10775003 CHANNELTM Steerable Sheath (8F compatible)XD10775004 CHANNELTM Steerable Sheath (9F compatible)2001398 TSXTM Transseptal Needle (89cm, 18G)
• Packaged coiled • Single use only
• Items per box: 1 • Supplied sterile • Heparin coated 8F
BARD® HD MESH ABLATOR SYSTEM
Ablation Catheters, Cables, and System
18
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
HD MESH ABLATOR EXTENSION CABLE KIT
BARD® TEMPULSETM PULSED RF CONTROLLER AND CABLES
BARD® CHANNELTM STEERABLE SHEATHAND TSXTM TRANSSEPTAL NEEDLE
Ablation Catheters, Cables, and System
BARD® RF CARDIAC ABLATION GENERATOR
When it comes to ablation, rely on the BARD® RF Cardiac Ablation Generator—state-of-the-art electronics that synthesize power, efficiency and simplicity. With an intuitive panel that’s easy to understand, the generator is compatible with a host of ablation products, and offers 100-watt capacity where and when you need it.
• Simplicity: Intuitive display panel facilitates ease-of-use
• Compatibility: Compatible with Bard’s unique TEMPULSETM
Controller—as well as various RF ablation catheters
• Power: 100-watt capability enables user to optimize a variety of electrode designs and configurations
Power andEase:
RedefiningYourAblation Procedures
19
Contact Your Local Representative for Product Availability: 1-800-824-8724
AblationCatheters,Cables, and System
Products Not Approved or Available in All Geographies.
Ordering Contact your local BARD® Representative Information in the event that replacement items are needed.
BARD® RF CARDIAC ABLATION GENERATOR
Ablation Catheters, Cables, and System
20
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Number Description
Bard’s Standard RF Ablation Catheters and Cables
2001285 100W RF Cardiac Ablation Generator (includes Generator with foot switch, RF Filter, and IECG cable)Various STINGERTM* Ablation Catheter (4mm/5mm/8mm distal tip electrodes)Various SCORPIONTM 2* Ablation Catheter (4mm/5mm/8mm distal tip electrodes)2001291 100 Watt TEMPLINKTM Cable2001292 100 Watt TEMPLINKTM M Cable
Accessories for use with other RF ablation catheters
2001409 EPT BLAZERTM Adapter Cable2001408 BIOSENSEWEBSTER® CELSIUSTM Adapter Cable2001335 MEDTRONICTM CONDUCTRTM Adapter Cable2001958 B-W Thermocool Adaptor Cable
*Refer to pps 5-13 for STINGERTM/SCORPIONTM 2 items.
21
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Diagnostic and Mapping Cathetersand Cables
BARD® HD MESH MAPPERTM CATHETERMapping Redefined
Through advanced mapping, placement, and control, the BARD® HD MESH
MAPPERTM Catheter is helping to redefine cardiac mapping.
The unique nature of the mesh braid along with 32-electrode high density construction provides ultra-precise positioning. It’s ideal for close mapping of the PV ostium, accurate identification of pulmonary vein potentials and the elimination of far field signals. The exclusive mesh disc is heparin coated.
The ergonomic handle was engineered to fit comfortably in the hand. The exclusive slide control mechanism actuates the mesh disk with excellent precision enabling the catheter to smoothly deploy in a variable range from 11-25mm.
The ability to record 32 unipolar or bipolar electrograms with support for clockwise or counter-clockwise orientation may yield a faster and safer procedure.
Compatible with BARD® 8F CHANNELTM Steerable Sheath and most other 8F Transseptal Sheaths.
Precise Positioning with Mesh
Helix Technology
Ergonomicsand Control
Superior Signal Quality
Compatibility
Advanced Mapping
Catalog French No. of Usable Number Size Electrodes Diameter Length
330002 8F 32 11-25mm 125cm
8F
BARD® HD MESH MAPPERTM CATHETER
Diagnostic and Mapping Catheters and Cables
22
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Cable Number Description Length
330050 2x16-pin color-coded cable 210cm
HDMESH MAPPERTM
EXTENSION CABLE KIT
• Packaged coiled • Single use only • Items per box: 1
• Supplied sterile • Compatible with most 8F sheaths • Heparin coated
• Items per box: 2 • Supplied sterile • Reusable
via 3X EO, 10X STERRADTM or Autoclave
Diagnostic and Mapping Catheters and Cables
ORBITERTM PVTMVARIABLE LOOP MAPPING CATHETERWe’ve got contact!
When it comes to pulmonary vein isolation in the treatment of focal atrial fibrillation, the challenges can be numerous. The ORBITERTM PVTM (OPV)Variable Loop Mapping Catheter has been designed to overcome these challenges. We’ve created a catheter that keeps you in contact from mapping through ablation and confirmation of post-ablation conduction block.
It’s no secret that true ostial positioning is a key element in successful and lasting outcomes. The OPV Variable Loop Mapping catheter is the first circular mapping catheter to combine an adjustable loop with a deflectable shaft. The variable loop design allowsyou to adjust the catheter’s diameter to maximize contact with the pulmonary vein atits most proximal point.
The clear signal quality that you are accustomed to from Bard Electrophysiology is only enhanced by the ability to adjust loop size and maximize electrode-to-tissuecontact with outward radial pressure.
One of the greatest challenges faced by electrophysiologists today is establishing ostialposition and maintaining orientation throughout the procedure. The ORBITERTM PVTM
Variable Loop Mapping catheter is built around a pressure-based positioning feature that maximizes stability in the physician-preferred location.
Among individual patients, pulmonary vein anatomy varies widely. By incorporating the ability to adjust loop diameter from 14.5mm to 25mm, we reduce the need for multiple fixed-diameter mapping catheters and their associated exchanges.
Location isEverything
Optimal Signal Quality
Stability
Procedural Efficiency
23
Contact Your Local Representative for Product Availability: 1-800-824-8724
Advanced Mapping
Products Not Approved or Available in All Geographies.
Catalog French Loop No. of Electrode UsableNumber Size Diameter Electrodes Spacing Length
320100 7.5F 14.5mm 14 5mm 105cm (5F tip) to 25mm
• Packaged coiled • .75mm electrodes
• Single use only • Items per box: 1
• 8F sheath compatibility • Supplied sterile7.5F
Catalog Cable Number Description Length
390008P* Protected 14-pin ORBITERTM STTM Cable 185cm
*Reusable via 3x EO Only
ORBITERTM PVTMVARIABLE LOOP MAPPING CATHETER
CABLES FOR ORBITERTM PVTM CATHETER
Diagnostic and Mapping Catheters and Cables
24
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Diagnostic and Mapping Catheters and Cables
25
Contact Your Local Representative for Product Availability: 1-800-824-8724
Steerable
Products Not Approved or Available in All Geographies.
THE RADIATM XT STEERABLE CS CATHETER FOR ULTIMATE PRECISION
Ease of PlacementOutstanding steerability enables precise coronary sinus placement.
StabilityExcellent stability and contact for signal clarity throughout the procedure.
Handling Control Ergonomic handle facilitates tactile response and comfort.
Exclusive Ergonomic Handle Recognizing the commitment to comfort
and ease of placement, the handle is designed to minimize fatigueand maximize control during the longest and most complicated procedures. The unique color-coded, twist-activated mechanism is 360 degrees accessible and the anti-slip rubber-coated handle enables precise placement.
BARD® EP•XTTM STEERABLE CATHETERAccuracy and Control to Speed Up and Simplify Intracardiac Mapping
The reliable, easy-to-steer BARD® EP•XTTM catheter offers an exceptional blend of shaft stability and curve control for fast, accurate mapping. And Bard’s exclusive point-of-tip actuation control supplies exceptional levels of tip response and control.
• Thumbwheel handle with user friendly design provides exceptional control.
• Patented curving mechanism allows smooth, precise incremental movement.
Soft, durometerpolyurethane
markedly reducesdistal tip trauma.
Gentle curve shape enables you to meet individual anatomical challenges.
The spring-coilcore and
wire-braid outerjacket combine toprovide superiorcolumn strength.
MaximumReach45 mm
26
Contact Your Local Representative for Product Availability: 1-800-824-8724
Diagnostic and Mapping Catheters and Cables
Products Not Approved or Available in All Geographies.
BARD® DYNAMIC TIPTM STEERABLE CATHETERAdvanced Steerability Right at Your Fingertips
With steerability and precise, fingertip control, the BARD®
DYNAMIC TIPTM steerable catheter lets you instantly actuate the curve in one easy movement. During manipulations, it permits controlled catheter rotation and prevents unwantedtensioning. The push-pull handle features a passive lock mechanism which secures the tip in place to reduce repositioning and ensure reliable wall contact, while the electrodes provide exceptional signal quality.
• Push-pull handle with automatic curve shape control technology provides smooth curve actuation and stable tip position.
• Superb cannulation capabilities provide precise control, even at the tip’s most distal point.
BARD® DYNAMIC XTTM STEERABLE CATHETERAdvanced Steerability and Control for Unparalleled Mapping Accuracy
The DYNAMIC XTTM Steerable Catheter system provides excellent access for intracardiac mapping, including the coronary sinus. Bard’s exclusive point-of-tip actuation control enables the DYNAMIC XTTM Steerable Catheter to achieve exceptional levels of tip responsiveness and control. A smooth curve (over the full curve segment) eliminates unintentional secondary curves to ensure easy advancement and accurate placement.
• Push-pull handle with automatic curve shape control technology provides smooth curve actuation and stable tip position.
• The spring coil core and wire-braid outer jacket combine to provide superior column strength.
• Soft, durometer polyurethane markedly reduces distal tip trauma.
The wire-braid outerjacket provides superiortorque control and column strength.
Soft, durometerpolyurethane markedly reducesdistal tip trauma.
Gentle curve shape enables you to meet individual anatomical challenges.
Soft, durometerpolyurethane markedly reducesdistal tip trauma.
Gentle curve shape enables you to meet individualanatomical challenges.
The spring coil core andwire-braid outer jacketcombine to provide superior column strength.
Diagnostic and Mapping Catheters and Cables
Steerable
27
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog French Curve Electrode Tip ProximalNumber Size Style Spacing Poles Electrode Electrode Length
230769 6F Large 5mm Quadpolar 2mm 1mm 110cm230770 6F Large 2,5,2mm Quadpolar 2mm 1mm 110cm231116 6F Large 1mm Quadpolar 2mm 1mm 110cm230771 6F Large 1cm Hexapolar 2mm 1mm 110cm230772 6F Large 2,5,2mm Hexaploar 2mm 1mm 110cm231009 6F Large 5mm Hexapolar 2mm 1mm 110cm230794 6F Large 2,5,2mm Octapolar 2mm 1mm 110cm230795 6F Large 2mm Octapolar 2mm 1mm 110cm230796 6F Large 5mm Octapolar 2mm 1mm 110cm230797 6F Large 2,10,2mm Octapolar 2mm 1mm 110cm230798 6F Large 1mm Octapolar 2mm 1mm 110cm231007 6F Large 2,5,2mm Decapolar 2mm 1mm 110cm
6F
BARD® RADIATM XT CATHETERS
Catalog Cable Number Use Length Description
560001A Autoclave or STERRADTM 10x Reuse or ETO 3x Reuse 210cm Protected 10-Pin SURELINKTM
560002A Autoclave or STERRADTM 10x Reuse or ETO 3x Reuse 120cm Protected 4-Pin SURELINKTM
560003A Autoclave or STERRADTM 10x Reuse or ETO 3x Reuse 210cm Protected 4-Pin SURELINKTM
560004A Autoclave or STERRADTM 10x Reuse or ETO 3x Reuse 120cm Protected 10-Pin SURELINKTM
CABLES
Large
Diagnostic and Mapping Catheters and Cables
Catalog French No. of Curve Electrode UsableNumber Size Electrodes Style Spacing Length Comments
200769 6F 4 Large 4.0 5mm 110cm200770 6F 4 Large 4.0 2,5,2mm 110cm201116 6F 4 Large 4.0 1mm 110cm
Large 4.0
• Packaged straight • Rotary steering
• Single use only • Items per box: 1
• Supplied sterile6F
Catalog French No. of Curve Electrode UsableNumber Size Electrodes Style Spacing Length Comments
200772 6F 6 Large 4.0 2,5,2mm 110cm200771 6F 6 Large 4.0 1cm 110cm201009 6F 6 Large 4.0 5mm 110cm
Large 4.0
• Packaged straight • Rotary steering
• Single use only • Items per box: 1
• Supplied sterile6F
EP•XTTM QUADPOLAR STEERABLE CATHETERS 6 FRENCH
EP•XTTM HEXAPOLAR STEERABLE CATHETERS 6 FRENCH
Catalog Cable Number Description Length
200088P* Protected 4-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog CableNumber Description Length
200089P* Protected 6-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
28
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Diagnostic and Mapping Catheters and Cables
Catalog French No. of Curve Electrode UsableNumber Size Electrodes Style Spacing Length Comments
200794 6F 8 Large 4.0 2,5,2mm 110cm200795 6F 8 Large 4.0 2mm 110cm200796 6F 8 Large 4.0 5mm 110cm200797 6F 8 Large 4.0 2,10,2mm 110cm200798 6F 8 Large 4.0 1mm 110cm Electrode spacing between
pole 1 and pole 2 is 2mm
Large 4.0
• Packaged straight • Rotary steering
• Single use only • Items per box: 1
• Supplied sterile6F
EP•XTTM OCTAPOLAR STEERABLE CATHETERS6 FRENCH
Catalog Cable Number Description Length
200774P* Protected 8-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode UsableNumber Size Electrodes Style Spacing Length Comments
201007 6F 10 Large 4.0 2,5,2mm 110cm
Large 4.0
• Packaged straight • Rotary steering
• Single use only • Items per box: 1
• Supplied sterile6F
EP•XTTM DECAPOLAR STEERABLE CATHETERS6 FRENCH
Catalog Cable Number Description Length
560001A* Protected 10-pin SURELINKTM cable 210cm 560004A* Protected 10-pin SURELINKTM cable 120cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Steerable
29
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Diagnostic and Mapping Catheters and Cables
30
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog French No. of Curve Electrode UsableNumber Size Electrodes Style Spacing Length Comments
200131 6F 4 Large 4.0 10mm 110cm200344 6F 4 Large 4.0 5mm 110cm
Large 4.0
• Packaged straight • Push-pull steering handle
• Single use only • Items per box: 1
• Supplied sterile6F
DYNAMIC TIPTM QUADPOLAR STEERABLE CATHETERS 6 FRENCH
Catalog Cable Number Description Length
200088P* Protected 4-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode UsableNumber Size Electrodes Style Spacing Length Comments
6DYNTP001 6F 10 Large 4.0 2,5,2mm 110cm
Large 4.0
• Packaged straight • Push-pull steering handle
• Single use only • Items per box: 1
• Supplied sterile6F
DYNAMIC TIPTM DECAPOLAR STEERABLE CATHETERS 6 FRENCH
Catalog Cable Number Description Length
560001A* Protected 10-pin SURELINKTM Cable 210cm560004A* Protected 10-pin SURELINKTM Cable 120cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Steerable
31
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Diagnostic and Mapping Catheters and Cables
Catalog French No. of Curve Electrode UsableNumber Size Electrodes Style Spacing Length Comments
201103 6F 4 Large 4.0 2,5,2mm 110cm201104 6F 4 Large 4.0 5mm 110cm201110 6F 4 Large 4.0 10mm 110cm201112 6F 4 Large 4.0 2mm 110cm201115 6F 4 Large 4.0 1mm 110cm
Large 4.0
• Packaged straight • Push-pull steering handle
• Single use only • Items per box: 1
• Supplied sterile6F
DYNAMIC XTTM QUADPOLAR STEERABLE CATHETERS6 FRENCH
Catalog Cable Number Description Length
200088P* Protected 4-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
201109 6F 6 Large 4.0 10mm 110cm201113 6F 6 Large 4.0 5mm 110cm201114 6F 6 Large 4.0 1mm 110cm
Large 4.0
• Packaged straight • Push-pull steering handle
• Single use only • Items per box: 1
• Supplied sterile6F
DYNAMIC XTTM HEXAPOLAR STEERABLE CATHETERS6 FRENCH
Catalog Cable Number Description Length
200089P* Protected 6-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Diagnostic and Mapping Catheters and Cables
32
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
201105 6F 8 Large 4.0 2,5,2mm 110cm201106 6F 8 Large 4.0 2mm 110cm201107 6F 8 Large 4.0 5mm 110cm201108 6F 8 Large 4.0 2,10,2mm 110cm
Large 4.0
• Packaged straight • Push-pull steering handle
• Single use only • Items per box: 1
• Supplied sterile6F
DYNAMIC XTTM OCTAPOLAR STEERABLE CATHETERS6 FRENCH
Catalog Cable Number Description Length
200774P* Protected 8-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
201101 6F 10 Large 4.0 2,5,2mm 110cm201102 6F 10 Large 4.0 2,6,2mm 110cm
Large 4.0
• Packaged straight • Push-pull steering handle
• Single use only • Items per box: 1
• Supplied sterile6F
DYNAMIC XTTM DECAPOLAR STEERABLE CATHETERS6 FRENCH
Catalog Cable Number Description Length
560001A* Protected 10-pin SURELINKTM cable 210cm560004A* Protected 10-pin SURELINKTM cable 120cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
33
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Diagnostic and Mapping Catheters and Cables
BARD®WOVEN DIAGNOSTIC CATHETERDiagnostic Performance Without Compromises
After more than 30 years, the BARD®Woven diagnostic catheter is still setting the standard for reliability and performance.
• Biosoftening characteristic allows the catheter tip to conform to the endocardial wall for excellent tissue contact.
• Softening response prevents endocardial bounce, providing greater stability and better signal quality.
BARD® WOVENFLEXIETM DIAGNOSTIC CATHETERThe Softness You Want, the Stability You Need
Bard’s WOVENFLEXIETM diagnostic catheter has the same features and functions that have made BARD®Woven catheters a favorite among electrophysiologists for more than 30 years. The WOVENFLEXIETM
catheter was introduced in response to physician requests for a softer tip to complement its exceptional stability. The primary difference between Bard’s WOVENFLEXIETM catheter and the original Woven catheter is the variable durometer coating system, which increases tip flexibility by 17%.
BARD® VIKINGTM DIAGNOSTIC CATHETERFeaturing Proprietary STABILENETM Polymer
For increased tip stability and greater torque control, BARD®
developed the BARD® VIKINGTM diagnostic catheter—the first diagnostic catheter to feature our unique STABILENETM polymer. The unique high-dampening properties of the STABILENETM polymer effectively reduce endocardial bounce, assuring reliable, long-term wall contact and less repositioning, even at the H.I.S.
• The shaft’s unique double-stranded braid provides total torque control.
• Compression-fit electrodes ensure consistently superb signal quality.
BARD® VIKING SOFT TIPTM DIAGNOSTICCATHETER, TANGOTM DIAGNOSTIC CATHETERTo give physicians an even greater choice within our BARD® VIKINGTM
family of endocardial catheters, BARD® has introduced the BARD®
VIKING SOFT TIPTM catheter and TANGOTM diagnostic catheter lines. Developed as an alternative to the original BARD® VIKINGTM
diagnostic catheter, these softer-tipped models feature STABILENETM, a unique, high-dampening polymer which offers a high degree of softness, curve retention, stability and control.
Fixed Curve
Gradually softening the braid’s polymer layerincreases tip flexibility up to 17% over our
standard Woven catheter.
To produce woven bioflexibility, the woven core is impregnated with a proprietary polymer
in an environment of strictly-controlled temperature and pressure.
Single braid
Unique double-stranded braid of the BARD® VIKINGTM, VIKING SOFT TIPTM andTANGOTM diagnostic catheters offer moretorque control than other catheters.
Double-strandedbraid
STABILENETM polymer construction as-sures consistent, long-term wall contact with less repositioning.
Endocardial wallOther catheters bounce…
…the BARD®
VIKINGTM, VIKING SOFT TIPTM
and TANGOTM
diagnosticcatheters hugthe endocardium
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
191001 6F 2 COURNANDTM 10mm 125cm
COURNANDTM
• Packaged coiled • 2mm platinum electrodes at
specified intervals • Single use only
• Items per box: 1 • Supplied sterile6F
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
004019P 4F 3 Damato 10mm 105cm Tails Connector Only004020P 5F 3 Damato 10mm 105cm Tails Connector Only200573 6F 3 JOSEPHSONTM 10mm 110cm
Damato JOSEPHSONTM
• Packaged coiled • 2mm platinum electrodes at
specified intervals • Single use only
• Items per box: 1 • Supplied sterile4-6F
WOVEN BIPOLAR CATHETERS6 FRENCH
WOVEN TRIPOLAR CATHETERS4-6 FRENCH
Diagnostic and Mapping Catheters and Cables
34
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
008568P* Protected 4-pin cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog CableNumber Description Length
200088P* Protected 4-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200150 4F 4 COURNANDTM 2,5,2mm 80cm 200152 4F 4 COURNANDTM 1mm 80cm 200151 4F 4 JOSEPHSONTM 2,5,2mm 80cm 200153 4F 4 JOSEPHSONTM 1mm 80cm
COURNANDTM JOSEPHSONTM
• Packaged coiled • 1mm platinum electrodes at
specified intervals • Single use only • Items per box: 1
• Supplied sterile4F
WOVEN QUADPOLAR CATHETERS4 FRENCH
Diagnostic and Mapping Catheters and Cables
Fixed Curve
35
Contact Your Local Representative for Product Availability: 1-800-824-8724
• Packaged coiled • 2mm platinum electrodes at
specified intervals • Single use only
• Items per box: 1 • Supplied sterile
6-7F
Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
008568P* Protected 4-pin cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200070S 6F 3 Damato 10mm 110cm 002853S 7F 3 Damato 10mm 110cm
WOVEN TRIPOLAR CATHETERS6-7 FRENCH WITH SURELINKTM CONNECTORS
Damato
Catalog CableNumber Description Length
560002A* Protected 4-pin SURELINKTM cable 120cm560002BA* Protected 4-pin (Blue) SURELINKTM cable 120cm560002RA* Protected 4-pin (Red) SURELINKTM cable 120cm560002YA* Protected 4-pin (Yellow) SURELINKTM cable 120cm560003A* Protected 4-pin SURELINKTM cable 210cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
201400 5F 4 Damato 10mm 110cm 200056 5F 4 COURNANDTM 10mm 110cm 200580 5F 4 COURNANDTM 5mm 110cm 200587 5F 4 COURNANDTM 5mm 110cm 1mm proximal electrodes200581 5F 4 COURNANDTM 2,5,2mm 110cm 200588 5F 4 COURNANDTM 2,5,2mm 110cm 1mm proximal electrodes200058 5F 4 JOSEPHSONTM 10mm 110cm 200060 5F 4 JOSEPHSONTM 5mm 110cm 200577 5F 4 JOSEPHSONTM 5mm 120cm
COURNANDTM Damato JOSEPHSONTM
• Packaged coiled • 2mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile
5F
WOVEN QUADPOLAR CATHETERS5 FRENCH WITH PROTECTED 4-PIN CONNECTORS
Diagnostic and Mapping Catheters and Cables
36
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Cable Number Description Length
008568P* Protected 4-pin cable 125cm*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200056E 5F 4 COURNANDTM 10mm 110cm 200580E 5F 4 COURNANDTM 5mm 110cm 200587E 5F 4 COURNANDTM 5mm 110cm 1mm proximal electrodes200581E 5F 4 COURNANDTM 2,5,2mm 110cm 200588E 5F 4 COURNANDTM 2,5,2mm 110cm 1mm proximal electrodes200058E 5F 4 JOSEPHSONTM 10mm 110cm 200060E 5F 4 JOSEPHSONTM 5mm 110cm 200577E 5F 4 JOSEPHSONTM 5mm 120cm 200062E 5F 4 Straight 10mm 110cm
COURNANDTM JOSEPHSONTM Straight
• Packaged coiled • 2mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile
5F
WOVEN QUADPOLAR CATHETERS 5 FRENCH WITH PROTECTED 4-PIN EASY-MATETM CONNECTORS
Catalog Cable Number Description Length
200088P* Protected 4-pin EASY-MATETM cable 125cm*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200574 6F 4 COURNANDTM 5mm 125cm 200583 6F 4 COURNANDTM 2,5,2mm 125cm 200590 6F 4 COURNANDTM 2,5,2mm 125cm 1mm proximal electrodes2001123 6F 4 COURNANDTM 10mm 110cm200578 6F 4 Damato 5mm 110cm 200586 6F 4 Damato 2,5,2mm 125cm 200593 6F 4 Damato 2,5,2mm 125cm 1mm proximal electrodes200624E 6F 4 JOSEPHSONTM 5mm 120cm 1.5mm proximal electrodes200584 6F 4 JOSEPHSONTM 2,5,2mm 125cm 200591 6F 4 JOSEPHSONTM 2,5,2mm 125cm 1mm proximal electrodes
COURNANDTM Damato JOSEPHSONTM
• Packaged coiled • 2mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile
6F
Diagnostic and Mapping Catheters and Cables
Catalog Cable Number Description Length
200088P* Protected 4-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Fixed Curve
37
Contact Your Local Representative for Product Availability: 1-800-824-8724
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200055P 5F 4 COURNANDTM 10mm 110cm 200063P 5F 4 Damato 10mm 110cm 200057P 5F 4 JOSEPHSONTM 10mm 110cm 200059P 5F 4 JOSEPHSONTM 5mm 110cm 200064P 5F 4 JOSEPHSONTM 2,5,2mm 110cm 200061P 5F 4 Straight 10mm 110cm
COURNANDTM Damato JOSEPHSONTM Straight
• Packaged coiled • 2mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile
5F
WOVEN QUADPOLAR CATHETERS5 FRENCH WITH TAILS TYPE CONNECTORS
Products Not Approved or Available in All Geographies.
WOVEN QUADPOLAR CATHETERS6 FRENCH WITH PROTECTED 4-PIN EASY-MATETM CONNECTORS
Diagnostic and Mapping Catheters and Cables
38
Contact Your Local Representative for Product Availability: 1-800-824-8724
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200472 6F 4 COURNANDTM 2mm 115cm 1mm proximal electrodes200582 6F 4 COURNANDTM 2,5,2mm 110cm 200589 6F 4 COURNANDTM 2,5,2mm 110cm 1mm proximal electrodes200792 6F 4 Damato 5mm 110cm 200585 6F 4 Damato 2,5,2mm 125cm 200592 6F 4 Damato 2,5,2mm 125cm 1mm proximal electrodes200473 6F 4 JOSEPHSONTM 2mm 115cm 1mm proximal electrodes
COURNANDTM Damato JOSEPHSONTM
• Packaged coiled • 2mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile
6F
WOVEN QUADPOLAR CATHETERS6 FRENCH WITH PROTECTED 4-PIN CONNECTORS
Products Not Approved or Available in All Geographies.
Catalog Cable Number Description Length
008568P* Protected 4-pin cable 125cm
*Reusable via 5x EO Only
CABLES
Diagnostic and Mapping Catheters and Cables
Fixed Curve
39
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200571P 6F 4 COURNANDTM 5mm 125cm200570P 6F 4 COURNANDTM 2,5,2mm 125cm200572P 6F 4 Damato 5mm 125cm006792P 6F 4 JOSEPHSONTM 5mm 120cm Includes Protected 4-pin 125cm cable
COURNANDTM Damato JOSEPHSONTM
• Packaged coiled • 2mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile
6F
COURNANDTM Damato JOSEPHSONTM Straight
• Packaged coiled • 2mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile
6-7F
WOVEN QUADPOLAR CATHETERS6 FRENCH WITH TAILS TYPE CONNECTORS
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
002943S 6F 4 Straight 10mm 110cm006245S 6F 4 COURNANDTM 10mm 110cm200719S 6F 4 Damato 10mm 110cm006798P 6F 4 JOSEPHSONTM 5mm 120cm200624S 6F 4 JOSEPHSONTM 5mm 120cm 1.5mm proximal electrodes200728S 6F 4 Straight 5mm 120cm 1.5mm proximal electrodes200066S 6F 4 COURNANDTM 5mm 125cm 1.5mm proximal electrodes200201S 6F 4 JOSEPHSONTM 10mm 125cm002944S 7F 4 Straight 10mm 110cm 200203S 7F 4 Damato 10mm 125cm
WOVEN QUADPOLAR CATHETERS6-7 FRENCH WITH SURELINKTM CONNECTORS
Catalog CableNumber Description Length
560002A* Protected 4-pin SURELINKTM cable 120cm560002BA* Protected 4-pin (Blue) SURELINKTM cable 120cm560002RA* Protected 4-pin (Red) SURELINKTM cable 120cm560002YA* Protected 4-pin (Yellow) SURELINKTM cable 120cm560003A* Protected 4-pin SURELINKTM cable 210cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Diagnostic and Mapping Catheters and Cables
40
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
201401 6F 5 JOSEPHSONTM 5,5,5,282mm 120cm 200594 6F 5 JOSEPHSONTM 5,5,5,152mm 120cm
JOSEPHSONTM
• Packaged coiled • 2mm platinum distal electrode • 1mm platinum
proximal electrode 5th electrode placed 17cm or 28cm from
distal tip to allow for unipolar recording • Single use only
• Items per box: 1 • Supplied sterile
6F
WOVEN PENTAPOLAR CATHETERS6 FRENCH
Catalog Cable Number Description Length
200089P* Protected 6-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200793 7F 4 Damato 5mm 110cm
Damato
• Packaged coiled • 2mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile7F
WOVEN QUADPOLAR CATHETERS7 FRENCH
Catalog Cable Number Description Length
008568P* Protected 4-pin cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200205 5F 6 COURNANDTM 10mm 110cm 200204 5F 6 COURNANDTM 5mm 110cm 200206 6F 6 COURNANDTM 10mm 125cm 200208 6F 6 COURNANDTM 5mm 125cm 200207 6F 6 JOSEPHSONTM 2,5,2mm 125cm
COURNANDTM JOSEPHSONTM
• Packaged coiled • 2mm platinum distal electrode
• 1mm platinum proximal electrodes at specified intervals
• Single use only • Items per box: 1 • Supplied sterile
5-6F
WOVEN HEXAPOLAR CATHETERS5 AND 6 FRENCH WITH PROTECTED 10-PIN CONNECTORS
Diagnostic and Mapping Catheters and Cables
Fixed Curve
41
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Cable Number Description Length
006590P* Protected 10-pin cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200205E 5F 6 COURNANDTM 10mm 110cm 200204E 5F 6 COURNANDTM 5mm 110cm 200575 6F 6 Straight 2,11,2,83,2mm 110cm 2mm proximal electrodes200579P 5F 6 COURNANDTM 2,5,2mm 100cm Tails Connector Only200085P 6F 6 Straight 10,10,10,70,10mm 110cm Tails Connector Only004178P 7F 6 Straight 10,80,10,20,10mm 105cm Tails Connector Only, 2mm proximal electrodes
COURNANDTM Straight
• Packaged coiled • 2mm platinum distal electrode
• 1mm platinum proximal electrodes at specified intervals
• Single use only • Items per box: 1 • Supplied sterile
5-7F
WOVEN HEXAPOLAR CATHETERS5, 6 AND 7 FRENCH WITH PROTECTED 6-PIN EASY-MATETM CONNECTORS
Catalog Cable Number Description Length
200089P* Protected 6-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200210 6F 8 COURNANDTM 5mm 125cm 200209 6F 8 COURNANDTM 1mm 125cm 200354 6F 8 COURNANDTM 1,10,1mm 125cm
COURNANDTM
• Packaged coiled • 2mm distal electrode
• 1mm proximal electrodes at specified intervals
• Single use only • Items per box: 1 • Supplied sterile6F
WOVEN OCTAPOLAR CATHETERS6 FRENCH
Diagnostic and Mapping Catheters and Cables
42
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Cable Number Description Length
006590P* Protected 10-pin cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200355 6F 10 COURNANDTM 5mm 125cm 200211 6F 10 COURNANDTM 2,5,2mm 125cm 200212 6F 10 COURNANDTM 2mm 125cm 200576 6F 10 Damato 2,5,2mm 110cm 2mm proximal electrodes200595 6F 10 Small 60 2,5,2mm 110cm 2mm proximal electrodes200612P 6F 10 JOSEPHSONTM 5,5,5,57,10,10 125cm Tails Connector Only, 10,10,10mm 2mm proximal electrodes
COURNANDTM Damato Small 60 JOSEPHSONTM
• Packaged coiled • 2mm platinum distal
electrode • 1mm platinum proximal
electrodes at specified intervals • Single use
only • Items per box: 1 • Supplied sterile
6F
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200567 5F 10 CS 2,5,2mm 65cm 200568 5F 10 CS 2,8,2mm 65cm
CS
• Packaged coiled • 2mm platinum distal electrode
• 1mm platinum proximal electrodes at specified intervals
• Single use only • Items per box: 1 • Supplied sterile
5F
WOVEN DECAPOLAR CATHETERS6 FRENCH WITH PROTECTED 10-PIN CONNECTORS
WOVEN DECAPOLAR CATHETERS5 FRENCH WITH PROTECTED 10-PIN SURELINKTM CONNECTORS
Diagnostic and Mapping Catheters and Cables
Fixed Curve
43
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Cable Number Description Length
006590P* Protected 10-pin cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog CableNumber Description Length
560001A* Protected 10-pin SURELINKTM cable 210cm 560004A* Protected 10-pin SURELINKTM cable 120cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Catalog French No. of Curve Electrode Usable Maximum Number Size Electrodes Style Spacing Length Guide Wire Comments
200076P 6F 4 COURNANDTM 10mm 110cm .60mm (.025") 200077P 6F 4 JOSEPHSONTM 5mm 110cm .60mm (.025") 200078P 6F 4 Damato 10mm 110cm .60mm (.025")
COURNANDTM Damato JOSEPHSONTM
• Packaged coiled • 2mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile6F
OPEN LUMEN WOVEN CATHETERS6 FRENCHThe Open Lumen catheter features a through lumen with two distal side holes. The lumenallows catheter introduction over a guide wire, and can be used for blood sampling, pressuremonitoring, and infusion.
Diagnostic and Mapping Catheters and Cables
44
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
008568P* Protected 4-pin cable 125cm006590P* Protected 10-pin cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
6FMC00789 6F 20 K 5,5,5,5,5, 110cm High Torque Sheath 5,5,5,5,42, 5,5,5,5,5,5, 5,5,5mm
K
• Packaged coiled • 2mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile6F
WOVEN 20-POLE CATHETERS 6 FRENCH
Catalog CableNumber Description Length
560004A* Protected 10-pin SURELINKTM cable 120cm560001A* Protected 10-pin SURELINKTM cable 210cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200596 5F 4 COURNANDTM 5mm 120cm 200597 5F 4 JOSEPHSONTM 5mm 120cm 200598 5F 4 JOSEPHSONTM 2,5,2mm 120cm 1mm proximal electrode500201 6F 4 JOSEPHSONTM 2mm 120cm 1mm proximal electrode500202 6F 4 COURNANDTM 5mm 120cm 500203 6F 4 JOSEPHSONTM 5mm 120cm 500204 6F 4 COURNANDTM 2mm 120cm 1mm proximal electrode500205 6F 4 JOSEPHSONTM 2,5,2mm 120cm 1mm proximal electrode500207 6F 4 Damato 5m 120cm
COURNANDTM JOSEPHSONTM Damato
• Packaged coiled • 2mm platinum electrode
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile5-6F
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
200599 5F 6 JOSEPHSONTM 2,5,2mm 120cm 500206 6F 6 JOSEPHSONTM 2,5,2mm 120cm
JOSEPHSONTM
• Packaged coiled • 2mm platinum distal electrode
• 1mm platinum proximal electrodes at specified intervals
• Single use only • Items per box: 1 • Supplied sterile5-6F
WOVENFLEXIETM QUADPOLAR CATHETERS5 AND 6 FRENCH
WOVENFLEXIETM HEXAPOLAR CATHETERS5 AND 6 FRENCH
Diagnostic and Mapping Catheters and Cables
Fixed Curve
45
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Cable Number Description Length
200088P* Protected 4-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog Cable Number Description Length
200089P* Protected 6-pin EASY-MATETM cable 125cm
*Reusable via 5x EO Only
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
400039 5F 2 JOSEPHSONTM 10mm 115cm 400040 5F 2 COURNANDTM 10mm 115cm 400037 6F 2 JOSEPHSONTM 10mm 115cm 400038 6F 2 COURNANDTM 10mm 115cm 400092P 5F 2 COURNANDTM 10mm 115cm Tails Connector Type Only400093P 6F 2 COURNANDTM 10mm 115cm Tails Connector Type Only
COURNANDTM JOSEPHSONTM
• Packaged coiled • 1.5mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile5-6F
VIKINGTM BIPOLAR CATHETERS5 AND 6 FRENCH
Diagnostic and Mapping Catheters and Cables
46
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
560002A* Protected 4-pin SURELINKTM cable 120cm560002BA* Protected 4-pin (Blue) SURELINKTM cable 120cm560002RA* Protected 4-pin (Red) SURELINKTM cable 120cm560002YA* Protected 4-pin (Yellow) SURELINKTM cable 120cm560003A* Protected 4-pin SURELINKTM cable 210cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
400041 5F 4 JOSEPHSONTM 2mm 115cm 400042 5F 4 COURNANDTM 2mm 115cm 400044 5F 4 JOSEPHSONTM 5mm 115cm 400045 5F 4 COURNANDTM 5mm 115cm 400046 5F 4 Damato 5mm 115cm 400050 5F 4 JOSEPHSONTM 10mm 115cm 400051 5F 4 COURNANDTM 10mm 115cm 400047 5F 4 JOSEPHSONTM 2,5,2mm 115cm 400043 5F 4 Damato 2mm 115cm 400048 5F 4 COURNANDTM 2,5,2mm 115cm 400122 5F 4 Hisser 2mm 115cm 400123 5F 4 Hisser 2,5,2mm 115cm 400124 5F 4 Hisser 5mm 115cm 400001 6F 4 JOSEPHSONTM 2mm 115cm 400002 6F 4 COURNANDTM 2mm 115cm 400003 6F 4 Damato 2mm 115cm 400004 6F 4 JOSEPHSONTM 5mm 115cm 400005 6F 4 COURNANDTM 5mm 115cm 400006 6F 4 Damato 5mm 115cm 400007 6F 4 JOSEPHSONTM 2,5,2mm 115cm 400008 6F 4 COURNANDTM 2,5,2mm 115cm 400009 6F 4 Damato 2,5,2mm 115cm 400010 6F 4 JOSEPHSONTM 10mm 115cm 400011 6F 4 COURNANDTM 10mm 115cm 400012 6F 4 Damato 10mm 115cm 400091P 6F 4 JOSEPHSONTM 5mm 115cm Tails Connector Type Only400094P 6F 4 COURNANDTM 10mm 115cm Tails Connector Type Only400102 6F 4 Levine 5mm 115cm 400119 6F 4 Hisser 2mm 115cm 400120 6F 4 Hisser 2,5,2mm 115cm 400121 6F 4 Hisser 5mm 115cm
COURNANDTM Damato JOSEPHSONTM Levine Hisser
• Packaged coiled • 1.5mm platinum
electrodes at specified intervals
• Single use only • Items per
box: 1 • Supplied sterile
5-6F
VIKINGTM QUADPOLAR CATHETERS5 AND 6 FRENCH
Diagnostic and Mapping Catheters and Cables
Fixed Curve
47
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
560002A* Protected 4-pin SURELINKTM cable 120cm560002BA* Protected 4-pin (Blue) SURELINKTM cable 120cm560002RA* Protected 4-pin (Red) SURELINKTM cable 120cm560002YA* Protected 4-pin (Yellow) SURELINKTM cable 120cm560003A* Protected 4-pin SURELINKTM cable 210cm*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
400088 5F 5 Interian 10mm 115cm 400090 6F 5 Interian 10,5,5,5mm 115cm
5-6F
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
400056 5F 6 JOSEPHSONTM 5mm 115cm400057 5F 6 COURNANDTM 5mm 115cm 400013 6F 6 JOSEPHSONTM 2mm 115cm 400014 6F 6 COURNANDTM 2mm 115cm 400015 6F 6 Damato 2mm 115cm 400016 6F 6 JOSEPHSONTM 5mm 115cm 400017 6F 6 COURNANDTM 5mm 115cm 400018 6F 6 Damato 5mm 115cm 400019 6F 6 JOSEPHSONTM 2,5,2mm 115cm 400020 6F 6 COURNANDTM 2,5,2mm 115cm 400021 6F 6 Damato 2,5,2mm 115cm 400022 6F 6 COURNANDTM 10mm 115cm 400118 6F 6 ELMHURSTTM 2,15,2mm 65cm
COURNANDTM Damato JOSEPHSONTM ELMHURSTTM
• Packaged coiled • 1.5mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile
• Packaged coiled • 1.5mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile
5-6F
VIKINGTM PENTAPOLAR CATHETERS5 AND 6 FRENCH
VIKINGTM HEXAPOLAR CATHETERS5 AND 6 FRENCH
Diagnostic and Mapping Catheters and Cables
48
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
560004A* Protected 10-pin SURELINKTM cable 120cm560001A* Protected 10-pin SURELINKTM cable 210cm*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Catalog CableNumber Description Length
560004A* Protected 10-pin SURELINKTM cable 120cm560001A* Protected 10-pin SURELINKTM cable 210cm*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Interian
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
400023 6F 8 JOSEPHSONTM 2mm 115cm 400024 6F 8 COURNANDTM 2mm 115cm 400025 6F 8 Damato 2mm 115cm 400026 6F 8 COURNANDTM 5mm 115cm 400027 6F 8 JOSEPHSONTM 2,5,2mm 115cm 400028 6F 8 COURNANDTM 2,5,2mm 115cm 400029 6F 8 Damato 2,5,2mm 115cm
COURNANDTM Damato JOSEPHSONTM
• Packaged coiled • 1.5mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile6F
VIKINGTM OCTAPOLAR CATHETERS6 FRENCH
Diagnostic and Mapping Catheters and Cables
Fixed Curve
49
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
560004A* Protected 10-pin SURELINKTM cable 120cm560001A* Protected 10-pin SURELINKTM cable 210cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
400096 5F 10 CS 2,5,2mm 65cm 400097 5F 10 CS 2,8,2mm 65cm 400098 5F 10 CS 2mm 65cm 400070 5F 10 JOSEPHSONTM 2mm 115cm 400071 5F 10 COURNANDTM 2mm 115cm 400074 5F 10 JOSEPHSONTM 2,5,2mm 115cm 400075 5F 10 COURNANDTM 2,5,2mm 115cm 400103 5F 10 CS 2,8,2mm 115cm 400104 5F 10 JOSEPHSONTM 5,5,5,20,5, 115cm 5,5,5,5mm 400099 6F 10 CS 2,5,2mm 65cm 400100 6F 10 CS 2,8,2mm 65cm 400101 6F 10 CS 2mm 65cm 400030 6F 10 JOSEPHSONTM 2mm 115cm 400031 6F 10 COURNANDTM 2mm 115cm 400032 6F 10 Damato 2mm 115cm 400033 6F 10 COURNANDTM 5mm 115cm 400034 6F 10 JOSEPHSONTM 2,5,2mm 115cm 400035 6F 10 COURNANDTM 2,5,2mm 115cm 400036 6F 10 Damato 2,5,2mm 115cm 400107 6F 10 ELMHURSTTM 2,5,2mm 65cm
CS COURNANDTM Damato JOSEPHSONTM ELMHURSTTM5-6F
VIKINGTM DECAPOLAR CATHETERS5 AND 6 FRENCH
Diagnostic and Mapping Catheters and Cables
50
Contact Your Local Representative for Product Availability: 1-800-824-8724
• Packaged coiled • 1.5mm platinum
electrodes at specified intervals
• Single use only • Items per box: 1
• Supplied sterile
Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
560004A* Protected 10-pin SURELINKTM cable 120cm560001A* Protected 10-pin SURELINKTM cable 210cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
400537 6F 2 JOSEPHSONTM 10mm 110cm 400538 6F 2 COURNANDTM 10mm 110cm 400501 6F 4 JOSEPHSONTM 2mm 110cm 400502 6F 4 COURNANDTM 2mm 110cm 400504 6F 4 JOSEPHSONTM 5mm 110cm 400505 6F 4 COURNANDTM 5mm 110cm 400506 6F 4 Damato 5mm 110cm 400507 6F 4 JOSEPHSONTM 2,5,2mm 110cm 400508 6F 4 COURNANDTM 2,5,2mm 110cm 400509 6F 4 Damato 2,5,2mm 110cm 400510 6F 4 JOSEPHSONTM 10mm 110cm 400511 6F 4 COURNANDTM 10mm 110cm 400512 6F 4 Damato 10mm 110cm 405119 6F 4 Hisser 2mm 110cm 405120 6F 4 Hisser 2,5,2mm 110cm 405121 6F 4 Hisser 5mm 110cm
COURNANDTM Damato JOSEPHSONTM
• Packaged coiled • 1.5mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile6F
VIKING SOFT TIPTM BIPOLAR AND QUADPOLAR CATHETERS 6 FRENCH
Diagnostic and Mapping Catheters and Cables
Fixed Curve
51
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
560002A* Protected 4-pin SURELINKTM cable 120cm560002BA* Protected 4-pin (Blue) SURELINKTM cable 120cm560002RA* Protected 4-pin (Red) SURELINKTM cable 120cm560002YA* Protected 4-pin (Yellow) SURELINKTM cable 120cm560003A* Protected 4-pin SURELINKTM cable 210cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Hisser
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
400530 6F 10 JOSEPHSONTM 2mm 110cm 400531 6F 10 COURNANDTM 2mm 110cm
COURNANDTM JOSEPHSONTM
• Packaged coiled • 1.5mm platinum electrodes
at specified intervals • Single use only
• Items per box: 1 • Supplied sterile6F
VIKING SOFT TIPTM DECAPOLAR CATHETERS6 FRENCH
Diagnostic and Mapping Catheters and Cables
52
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
560004A* Protected 10-pin SURELINKTM cable 120cm560001A* Protected 10-pin SURELINKTM cable 210cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Catalog French No. of Curve Electrode UsableNumber Size Electrodes Style Spacing Length Comments
400540 5F 2 COURNANDTM 10mm 110cm400539 5F 2 JOSEPHSONTM 10mm 110cm400551 5F 4 COURNANDTM 10mm 110cm400553 5F 4 COURNANDTM 2,5,2mm 110cm400545 5F 4 COURNANDTM 5mm 110cm400542 5F 4 COURNANDTM 2mm 110cm400546 5F 4 Damato 5mm 110cm405123 5F 4 Hisser 2,5,2mm 110cm405122 5F 4 Hisser 2mm 110cm405124 5F 4 Hisser 5mm 110cm400550 5F 4 JOSEPHSONTM 10mm 110cm400552 5F 4 JOSEPHSONTM 2,5,2mm 110cm400541 5F 4 JOSEPHSONTM 2mm 110cm400544 5F 4 JOSEPHSONTM 5mm 110cm
COURNANDTM JOSEPHSONTM Damato
• Packaged coiled • 1.5mm platinum
electrodes at specified intervals
• Single use only • Items per box: 1
• Supplied sterile
5F
TANGOTM BIPOLAR AND QUADPOLAR CATHETERS5 FRENCH
Diagnostic and Mapping Catheters and Cables
Fixed Curve
53
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
560002A* 4-pin SURELINKTM 120cm560002BA* 4-pin SURELINKTM (Blue) 120cm560002RA* 4-pin SURELINKTM (Red) 120cm560002YA* 4-pin SURELINKTM (Yellow) 120cm560003A* 4-pin SURELINKTM 210cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Hisser
Catalog French No. of Curve Electrode Usable Number Size Electrodes Style Spacing Length Comments
400549 5F 5 Interian 10,5,5,5mm 110cm400557 5F 6 COURNANDTM 5mm 110cm400571 5F 10 COURNANDTM 2mm 110cm400575 5F 10 COURNANDTM 2,5,2mm 110cm400577 5F 10 CS 2,5,2mm 110cm400579 5F 10 CS 2,8,2mm 110cm400572 5F 10 CS 2mm 110cm400576 5F 10 ELMHURSTTM 2,5,2mm 110cm400570 5F 10 JOSEPHSONTM 2mm 110cm400574 5F 10 JOSEPHSONTM 2,5,2mm 110cm
COURNANDTM CS ELMHURSTTM JOSEPHSONTM
• Packaged coiled • 1.5mm
platinum electrodes at specified
intervals • Single use only
• Items per box: 1 • Supplied sterile
5F
TANGOTM MULTIPOLE CATHETERSPENTAPOLAR, HEXAPOLAR, DECAPOLAR5 FRENCH
Diagnostic and Mapping Catheters and Cables
54
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog CableNumber Description Length
560004A* 10-pin SURELINKTM 120cm560001A* 10-pin SURELINKTM 210cm
*Reusable via 3X ETO/10X STERRADTM/10X Autoclave
CABLES
Interian
Ease of Placement, Stability &
Clarity
Access
Stability
Functionality
Diagnostic and Mapping Catheters and Cables
55
Contact Your Local Representative for Product Availability: 1-800-824-8724
Atrial Mapping
Products Not Approved or Available in All Geographies.
MilwaukeeCurve
ORBITERTM-Small Curve
ORBITERTM-Large Curve
RADIA™ BIDIRECTIONAL DIAGNOSTIC CATHETERStability You Can Rely On. Clarity You Can Trust.
The RADIA™ Bidirectional Diagnostic Catheter optimizes tissue contact via a unique shaft construction, facilitating stability and signal clarity throughout the procedure. A new, ergonomic handle design enables 360° access for comfort and ease of placement. Asymmetrical curve options in one catheter meet your clinical needs and reduce inventory.
New ergonomic handle for 360° access and rapid, precise placement
Excellent stability and contact for signal clarity throughout the procedure
Asymmetric curve configurations for optimal versatility in one catheter
ORBITERTM STTM 20-POLE STEERABLE CATHETERFlexibility, Comfort and Control for More Accurate Atrial Flutter Diagnosis
The ergonomically designed, 20-pole ORBITERTM STTM steerable catheter offers the ultimate combination of features and functionality necessary for accurate atrial mapping. Inside the shaft, a spring core works in harmony with the wire-braided Pebax jacket to provide superior lateral flexibility and column strength. The lightweight handle allows convenient, one-hand control, while reducing fatigue during lengthy procedures.
• Bidirectional curve actuation allows easy positioningalong the septum, roof and lateral wall.
• Patented CURVELOCKTM Mechanism locks the tip in place and keeps it right on target.
• The ergonomic handle and thumb-slide actuator add comfort and convenient, one-hand control.
ORBITERTM ATRIAL MAPPING CATHETERS
The small and large ORBITERTM Atrial Mapping catheter fixed curves are ideal for recording along the septum, roof, lateral wall, and isthmus of the right atrium. The large curve is specially designed for added stability in an enlarged atrium. Hi-Torque catheters offer more body in the shaft for greater torque and ease of repositioning.
The easily steerable, 20-electrode array is ideally suited for your
most challenging cases.
The ORBITERTM STTM 20-PoleSteerable catheter
provides superior shaft performance, even in the most
challenging anatomies.
Bidirectional curve actuationallows easy positioning along
the septum, roof and lateral wall.
56
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Diagnostic and Mapping Catheters and Cables
Catalog French No. of Curve Electrode Usable TipNumber Size Electrodes Style Spacing Length Length
320011G 7F 10 D Type 2,5,2mm 95cm 62mm320012G 7F 20 Extra Large 2,14,2mm 95cm 187mm320013G 7F 20 Extra Large 2,10,2mm 95cm 157mm320014G 7F 20 Medium 2mm 95cm 140mm320015G 7F 20 Extra Large 5mm 95cm 187mm320016G 7F 20 Medium 2,7,2mm 95cm 130mm320017G 7F 20 Extra Large 2,5,2mm 95cm 157mm320018G 7F 20 Extra Large 2,20,2,2,2,2,2, 95cm 166mm 2,2,2,2,2,2,25, 2,25,2,25,2mm320019G 7F 20 Cristalis 1,3,1mm 95cm 67mm320020G 7F 20 Extra Large 2,8,2,8,2,8,2,8 95cm 187mm 2,60,2,8,2,8,2, 8,2,8,2mm
• Packaged Coiled • Single use only
• Items per box: 1 • Supplied sterile 7FMedium Extra Large CristalisD Type
Catalog CableNumber Description Length
390003P* Protected 24-pin ORBITERTM STTM cable 120cm390004P* Protected 24-pin ORBITERTM STTM cable 210cm
*Reusable via 3x EO Only
CABLES
RADIA™ BIDIRECTIONAL DIAGNOSTIC CATHETER7 FRENCH
Diagnostic and Mapping Catheters and Cables
57
Contact Your Local Representative for Product Availability: 1-800-824-8724
Atrial Mapping
Products Not Approved or Available in All Geographies.
Catalog French No. of Curve Electrode Recording Usable Number Size Electrodes Style Spacing Span Length Comments
320001 7F 20 Large 2,14,2mm 167mm 95cm320002 7F 20 Small 2,10,2mm 131mm 95cm320003 7F 10 D Type 2,5,2mm 41mm 95cm320004 7F 20 Small 2,2,2mm 59mm 95cm320005 7F 20 Small 5,5,5mm 116mm 95cm320006 7F 20 Small 2,7,2mm 104mm 95cm320007 7F 20 Small 2,5,2mm 86mm 95cm320008 7F 20 Small 2,20,2,2,2,2,2,2,2,2 146mm 95cm 2,2,2,25,2,25,2,25,2mm320009 7F 20 D Type 1,3,1mm 59mm 95cm
Small 2.0 Large 4.0 D Type
• Packaged coiled • 2mm platinum distal electrode
• 1mm platinum proximal electrode at specified
intervals • Slider handle • Single use only
• Items per box: 1 • Supplied sterile
7F
STEERABLE ORBITERTM STTM CATHETERS7 FRENCH
Catalog Cable Number Description Length
390003P* Protected 24-pin ORBITERTM STTM cable 120cm390004P* Protected 24-pin ORBITERTM STTM cable 210cm
*Reusable via 3x EO Only
CABLES
ORBITERTM-Small ORBITERTM-
Large
Damato Milwaukee Small 60
• Packaged coiled • 2mm platinum distal electrodes
• 1mm platinum proximal electrodes at specified
intervals • Single use only • Items per box: 1
• Supplied sterile
6F
FIXED CURVE ORBITERTM CATHETERS6 FRENCH
Catalog French No. of Curve Electrode Recording UsableNumber Size Electrodes Style Spacing Span Length Comments
242401 6F 24 Milwaukee 2,4,2mm 93mm 110cm242402 6F 24 ORBITERTM-Small 2,4,2mm 93mm 110cm242403 6F 24 ORBITERTM-Small 2,7,2mm 126mm 110cm242404 6F 24 ORBITERTM-Large 2,7,2mm 126mm 110cm242405 6F 24 ORBITERTM-Small 2,9,2mm 171mm 110cm 2mm proximal electrodes242406 6F 24 ORBITERTM-Large 2,9,2mm 171mm 110cm 2mm proximal electrodes
161601 6F 16 Small 60 1,5,1mm 60mm 110cm161602 6F 16 Small 60 1,5,1mm 60mm 80cm161603 6F 16 Damato 1,5,1mm 60mm 80cm
Catalog Cable Number Description Length
200774P* Protected 8-pin EASY-MATETM cable 125cm
24-Electrode Configuration: Requires (3) Protected 8-pin EASY-MATETM cables16-Electrode Configuration: Requires (2) Protected 8-pin EASY-MATETM cables
*Reusable via 5x EO Only
CABLES
Diagnostic and Mapping Catheters and Cables
58
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog French No. of Curve Electrode Recording UsableNumber Size Electrodes Style Spacing Span Length Comments
242411 6F 24 ORBITERTM-Small 2,4,2mm 93mm 110cm242412 6F 24 ORBITERTM-Small 2,7,2mm 126mm 110cm242414 6F 24 ORBITERTM-Small 2,9,2mm 171mm 110cm 2mm proximal electrodes242413 6F 24 ORBITERTM-Large 2,7,2mm 126mm 110cm242415 6F 24 ORBITERTM-Large 2,9,2mm 171mm 110cm 2mm proximal electrodes242416 6F 24 Milwaukee 2,4,2mm 93mm 110cm
ORBITERTM-Small ORBITERTM-
Large
Milwaukee
• High Torque Shaft packaged coiled • 2mm platinum
distal electrode • 1mm platinum proximal
electrodes at specified intervals • Single use only
• Items per box: 1 • Supplied sterile
6F
HIGH TORQUE FIXED CURVE ORBITERTM CATHETERS6 FRENCH
Catalog Cable Number Description Length
200774P* Protected 8-pin EASY-MATETM cable 125cm
24-Electrode Configuration: Requires (3) Protected 8-pin EASY-MATETM cables16-Electrode Configuration: Requires (2) Protected 8-pin EASY-MATETM cables
*Reusable via 5x EO Only
CABLES
Diagnostic and Mapping Catheters and Cables
Atrial Mapping
59
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
60
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Diagnostic and Mapping Catheters and Cables
61
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Specials Program
Ever imagine a
custom-tailored
catheter thatcould meet a unique
application?
Now, let imagination
become reality.
Bard Electrophysiology.
Products you can
count on.
SPECIAL ORDER PROGRAM
The Bard Electrophysiology Special Order Program demonstrates our commitment to developing products that suit virtually any requirement.
As a pioneer and leader in EP, it’s a commitment we’re proud of.
With choices for electrode spacing and configuration, curve type and connectortype, you get a product that is custom-designed to your preferences. The BARD®
Special Order Program uses the same high-performance materials and precisiontooling found in standard catalog items to produce a wide range of catheter options for both routine and demanding clinical applications. The Special OrderProgram includes the Woven, WOVENFLEXIETM, ORBITERTM, VIKINGTM, VIKINGSOFT TIPTM, TANGOTM, EP•XTTM, DYNAMIC TIPTM, DYNAMIC XTTM and ORBITERTM
STTM diagnostic and mapping catheters. Please refer to Specials Matrix for fullrange of options.
The BARD® Special Order Program is based on a unique, tri-level ordering system which optimizes efficiency and management of resources.
Custom Orders*
• Made to order, a 6-week lead time
As Needed Orders**
• Based on a signed usage volume agreement, inventory levels are maintained by BARD®, no lead time required
Featured Orders***
• Certain items only
• No agreement or minimum order required, no lead time required
* For outside US, please allow additional time for shipping.** Not available outside US.*** Not available in all geographies.
62
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
63
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Intracardiac Access Products
DiRexTMSteerable Sheath
DIREXTM STEERABLE SHEATHThe DIREXTM Steerable Sheath is a low profile, bidirectional steerable sheath.
Features
• Bidirectional steering
• Soft, atraumatic tip
• Braided shaft
• Hemostatic Valve
• Compatible with 0.038"/0.97mm guidewires
• Ergonomic handle
Curve Length Dialator and French Size
Locking Mechanism
64
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Intracardiac Access Products
DIREXTM STEERABLE SHEATH8.51012F
Catalog French Sheath Curve Number Size Length Style Dilator
DS8501750 8.5F 71cm Small (17mm) 50º CurveDS8502250 8.5F 71cm Medium (22mm) 50º CurveDS8505050 8.5F 71cm Large (50mm) 50º CurveDS8501700 8.5F 71cm Small (17mm) StraightDS8502200 8.5F 71cm Medium (22mm) StraightDS8505000 8.5F 71cm Large (50mm) StraightDS1002250 10F 67cm Medium (22mm) 50º CurveDS1002200 10F 67cm Medium (22mm) StraightDS1205050 12F 67cm Large (50mm) 50º CurveDS1205000 12F 67cm Large (50mm) Straight
Intracardiac Access Products
EZCrossTMIntroducer Kit
65
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
EZCROSSTM INTRODUCER KITThe BARD® EZCROSSTM Introducer Kit provides a smooth crossing profile and excellent torque response for successful transseptal catheterization procedures.
Features
• Braided shaft
• Locking dilator
• Five curve choices
• Smooth inner lumen
• Radiopaque marker
• Two-sided holes
• Tapered, soft distal tip
• Haemostatic valve
• 3-Way stopcock
• Cuved dilator
Locking Dilator 3-Way Stopcock Hemostatic Valve
Intracardiac Access Products
66
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
EZCROSSTM INTRODUCER KIT
Specifications
Item Measurement
French Size Compatibility 8.5 French
Sheath Inner Diameter (ID) 0.111" (8.5F)
Sheath Usable Length 60cm
Sheath Radiopaque Marker Platinum Band
Sheath Curves Sizes 30˚, 55˚, 120˚ Short, 120˚ Long, and 150˚i
Dilator Usable Length 65cm
Dilator Inner Diameter 0.038"
Guide Wire Max Outer Diameter 0.035"
Guide Wire Length 135cm
Catalog Sheath Sheath SheathNumber Size Curve Length
EZC030060 8.5F 30˚ Curve 60cmEZC055060 8.5F 55˚ Curve 60cmEZC120S060 8.5F 120˚ Short Curve 60cmEZC120L060 8.5F 120˚ Long Curve 60cmEZC150060 8.5F 150˚i Curve 60cm
67
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Intracardiac Access Products
SafeSheath®Ultra Introducer
SAFESHEATH® ULTRA INTRODUCERThe SAFESHEATH® Ultra Introducer combines a tear-away introducer and hemostatic valve to reduce back bleeding and the possibility of air embolism.
Features• Extruded score line peel-away sheath designed for clean, even peeling duringremoval.
• Hemostatic valve with low insertion and withdrawal forces permits multiplelead insertions without further interventions.
• Ergonomically designed, easy splitting break-away hub.
• Low profile luer activated side port for infusion and contrast injection.
• Positive locking dilator connector.
• Reduced risk of blood loss and air embolism.
SAFESHEATH®ULTRA INTRODUCER
SAFESHEATH® ULTRA INTRODUCER LONG
Low profile luer activated side portfor infusion and contrast injection
Extruded score line peel-awaysheath with easy splitting break-away hemostasis valve
Ergonomically designed hub withprinted French size
Silicone oil-freeconstruction
68
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Intracardiac Access Products
DilatorModel Description Length (cm)
SU6 6.0F x 13cm Tear-away valved sheath system w/side port 18SU7 7.0F x 13cm Tear-away valved sheath system w/side port 18SU8 8.0F x 13cm Tear-away valved sheath system w/side port 18SU9 9.0F x 13cm Tear-away valved sheath system w/side port 18SU95 9.5F x 13cm Tear-away valved sheath system w/side port 18SU10 10.0F x 13cm Tear-away valved sheath system w/side port 18SU105 10.5F x 13cm Tear-away valved sheath system w/side port 18SU11 11.0F x 13cm Tear-away valved sheath system w/side port 18
GuideWire for standard SAFESHEATH® is 50cm long with O.D. of .038"
SAFESHEATH® ULTRA INTRODUCER LONG
DilatorModel Description Length (cm)
SUL7 7.0F x 23cm Tear-away valved sheath system w/side port 28SUL8 8.0F x 23cm Tear-away valved sheath system w/side port 28SUL9 9.0F x 23cm Tear-away valved sheath system w/side port 28
GuideWire for SAFESHEATH® Long is 50cm long with O.D. of .038"
SAFESHEATH® ULTRA INTRODUCER
BARD® CHANNELTM STEERABLE SHEATHRight Place, Right Time, Right Sheath—Every Time
The pin-point control and stability of the BARD® CHANNELTM Steerable Sheath provide critical capabilities for all successful ablation cases.
The BARD® CHANNELTM Steerable Sheath features the CURVELOCKTM Mechanism,which enables the sheath to remain in position once set.
A range of motion allows for excellent maneuverability, while active straightening ensures precise control.
The shaft is braided for optimal torque and kink resistance, and has an innerPTFE liner for the smooth advancement of devices.
A radiopaque marker band at the tip of the sheath provides convenientvisualization and flush holes to allow for continuous heparin delivery.
Available in two french sizes: 8 french and 9 french
Accommodates an 89cm standard TSXTM
Transseptal needle.
CURVELOCKTM
Mechanism
Braided Shaft
RadiopaqueMarker Band
Intracardiac Access Products
Bard® ChannelTMSteerable Sheath
69
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
The BARD® CHANNELTM Steerable Sheath...Versatile, Consistent and Superior
0-180 DegreeSteerability
8-9F BARD® CHANNELTM STEERABLE SHEATH
8Fr BARD® CHANNELTM 9Fr BARD® CHANNELTM
Specifications Steerable Sheath Steerable Sheath
Catalog Number XD10775003 XD10775004
French Size Compatibility 8 French 9 French
Sheath Inner Diameter (ID) 8.3 French / 2.8mm 9.8 French / 3.3mm
Sheath Outer Diameter (OD) 11.4 French / 3.8mm 12.6 French / 4.2mm
Sheath Usable Length 67cm 67cm
Sheath Radiopaque Marker 0.25 inches / 0.25 inches / 6.35mm from tip 6.35mm from tip
Sheath Turning Range 0 to 180 degrees 0 to 180 degrees
Dilator Usable Length 86cm 86cm
Transseptal Needle Compatibility 89cm needle 89cm needle
Dilator ID Compatibility 0.038 inches / 1mm 0.038 inches / 1mm
Intracardiac Access Products
70
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
• Items per box: 1 • Supplied sterile • Single use only
71
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
TSXTM TRANSSEPTAL NEEDLES
• The ergonomic handle design and tapered tip transition offer EP physicians enhanced manipulation and control during transseptal crossing procedures.
• Tapered tip transition
• Made of stainless steel
Use the TSXTM Transseptal Needle with the BARD® CHANNELTM Sheath to access the control tip feature, which ensures a set needle deployment every time.
TSXTMTransseptalNeedles
Intracardiac Access Products
Catalog Curve Number Style Indication Size Length
2001298 Standard Adult 18 Gauge 71cm2001299 Large Adult 18 Gauge 71cm2001398 Standard Adult 18 Gauge 89cm2001498 Standard Adult 18 Gauge 98 cm2001499 Large Adult 18 Gauge 98 cm
• Packaged for single use • Latex free • Items per box: 1 • Supplied sterile
72
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Temporary Pacing Electrodes
TEMPORARY PACING ELECTRODE CATHETERS
The BARD® Temporary Pacing Electrode Catheters are designed and built with the quality that has been a BARD® trademark for more than 25 years. Their unique construction provides many clinical benefits as outlined below:
Reduces the need for repositioning, saving physician time and minimizing patient discomfort.
Enables the electrode to maintain contact with the endocardium, assuring consistent pacing and sensing.
Facilitates easy and accurate placement, even in difficult anatomies, which mayreduce procedure time.
Proprietary manufacturing process yields an ultra-smooth coating and polished surface.
BARD® offers a full line of electrodes for most temporary pacing needs. • The NBIHTM and GOETZTM catheter lines are ideal for use in the cath lab or
the critical care unit when fluoroscopy is available.
• The Balloon Flow-Assisted catheter line is suited for emergency cases andin critical care units where fluoroscopy is not readily available.
• The ZUCKERTM, MYLERTM, and GORLINTM catheters are open-lumen diagnostic pacing catheters useful during right heart procedures and critical care unit monitoring.
OutstandingStability
Tip Spring Construction
Excellent Torque Control
73
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
5-7F
4-6F
5-6F
Catalog French Overall Number Size Length
007150P 5F 100cm007151P 5F 125cm007152P 6F 100cm007153P 6F 125cm007406P 7F 125cm
• Woven construction • First electrode: distal tip
• Second electrode: 1cm proximal • Useful in the cath lab or critical care unit
• Single use only • Items per box: 5 • Supplied sterile • No latex
NBIHTM BIPOLAR PACING ELECTRODE CATHETERS5-7 FRENCH
Catalog French Overall Number Size Length
007417P 4F 125cm007250P 5F 100cm007253P 6F 125cm006395P 6F 115cm
• Single use only • Items per box: 5 • Supplied sterile
NBIHTM BIPOLAR PACING ELECTRODE CATHETERS 4-6 FRENCH WITH NEEDLE/CANNULA
Temporary Pacing Electrodes
74
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
NBIHTM Bipolar Electrode CatheterNote: Catheter has adapter for protected pin connection
Catalog French Overall Number Size Length
007154P 5F 100cm007155P 5F 125cm007156P 6F 100cm007157P 6F 125cm
• Woven construction • First electrode: distal tip
• Second electrode: 2.5cm proximal • Bridges infarcted tissue for pacing most myocardial
infarction patients • Single use only • Items per box: 5 • Supplied sterile • No latex
GOETZTM BIPOLAR PACING ELECTRODE CATHETERS5-6 FRENCH
GOETZTM Bipolar Electrode CatheterNote: Catheter has adapter for protected pin connection
NBIHTM Bipolar Electrode Catheter with Needle/CannulaNote: Catheter has adapter for protected pin connection
Catalog French Overall Number Size Length
057152P 6F 100cm057153P 6F 125cm057406P 7F 125cm
• Soft tip design enables atraumatic placement • Woven construction
• First electrode: distal tip • Second electrode: 1cm proximal • Useful in the cath lab or
critical care unit • Single use only • Items per box: 5 • Supplied sterile • No latex
6-7F
NBIHTM SOFT TIP BIPOLAR PACING ELECTRODE CATHETERS6-7 FRENCH
Temporary Pacing Electrodes
75
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
NBIHTM Soft Tip Bipolar Pacing Electrode CatheterNote: Catheter has adapter for protected pin connection
Catalog French Overall Number Size Length
057156P 6F 100cm057157P 6F 125cm
• Soft and flexible distal tip • Woven construction • First electrode: distal tip
• Second electrode: 2.5cm proximal • Bridges infarcted tissue for pacing most myocardial
infarction patients • Single use only • Items per box: 5 • Supplied sterile • No latex
6F
GOETZTM SOFT TIP BIPOLAR PACING ELECTRODE CATHETERS6 FRENCH
GOETZTM Soft Tip Bipolar Pacing Electrode CatheterNote: Catheter has adapter for protected pin connection
Catalog French Number Size Length
006221P� 4F 115cm Usable006225P� 5F 115cm Usable006241P 6F 125cm Overall006242P 7F 125cm Overall� 4F & 5F electrodes include depth markings
• Lightweight construction for easy flow-assisted placement into ventricular apex
• First electrode: distal tip • Second electrode: 1cm proximal
• 4F, 5F & 6F product packaged with ECG adapter and needle/cannula
• Single use only • Items per box: 5 • Supplied sterile • No latex
4-7F
SEMI-FLOATING BIPOLAR PACING ELECTRODE CATHETERS4-7 FRENCH
Temporary Pacing Electrodes
76
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Semi-Floating Bipolar Pacing Electrode CatheterNote: Catheter has adapter for protected pin connection
Catalog French Usable Number Size Length
008153P� 4F 115cm008154P� 5F 115cm� 4F & 5F electrodes include depth markings
• Useful when fluoroscopy is not available for patients requiring temporary pacing
• Heparin-bonded pacing electrode • Provides stability and reliable capture
in right ventricle • First electrode: distal tip • Second electrode: 1cm proximal
• 4F & 5F product packaged with ECG adapter and needle/cannula
• Single use only • Items per box: 5 • Supplied sterile • No latex
4-5F
SPECIAL CARE BIPOLAR PACING ELECTRODE CATHETERS4–5 FRENCH
Special Care Bipolar Pacing Electrode CatheterNote: Catheter has adapter for protected pin connection
• Useful when fluoroscopy is not available for patients requiring temporary pacing
• Full bodied shaft construction • First electrode: distal tip • Second electrode: 1cm
proximal • Packaged with ECG adapter, balloon inflation syringe and needle/cannula
• Single use only • Items per box: 5 • Supplied sterile • Latex
4-5F
BALLOON FLOW-ASSISTED BIPOLAR ELECTRODE CATHETERS4-5 FRENCH
Temporary Pacing Electrodes
77
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Balloon Flow Assisted Bipolar Pacing Electrode CatheterNote: Catheter has adapter for protected pin connection
Catalog French Usable Number Size Length
520004P 5F 110cm Heparin Bonded520007P 5F 110cm Non-Heparin Bonded
• Designed for quick, atraumatic insertion from femoral approach • Full bodied shaft for
excellent torque control and responsive handling • First electrode: distal tip
• Second electrode: 1cm proximal • Packaged with ECG adapter, balloon inflation syringe
and needle/cannula • Single use only • Items per box: 5 • Supplied sterile • Latex
5F
BALLOON PACING BIPOLAR ELECTRODE CATHETERS 5 FRENCH WITH RIGHT HEART CURVE
Balloon Pacing Bipolar Electrode Catheter with Right Heart CurveNote: Catheter has adapter for protected pin connection
Catalog French Usable Number Size Length
008635P� 4F 110cm Heparin Bonded008556P� 5F 110cm Heparin Bonded006172P 4F 110cm Non-Heparin Bonded006173P 5F 110cm Non-Heparin Bonded� 4F & 5F electrodes include depth markings
Catalog French Lumen Number Size Length
051510P 6F 100cm051511P 6F 125cm051512P 7F 100cm051513P 7F 125cm
• Ideal for right heart and bipolar pacing, intracardiac ECG, sampling, and infusion
• Woven open lumen construction with 2mm electrodes and distal side holes
• Soft tip • First electrode: distal tip • Second electrode: 1.5cm proximal
• Single use only • Items per box: 1 • Supplied sterile
6-7F
ZUCKERTM LUMEN ELECTRODE CATHETERS6-7 FRENCH
Temporary Pacing Electrodes
78
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
ZUCKERTM Lumen Electrode CatheterNote: Catheter has adapter for protected pin connection
Catalog French Lumen Number Size Length
054015P 7F 125cm
• Ideal for pulmonary artery pressure monitoring and sampling, while simultaneously pacing
the right ventricle • Woven open lumen construction with 2mm electrodes and distal side
holes • Soft tip • First electrode: 11cm from distal tip • Second electrode: 1cm proximal
from first electrode • Single use only • Items per box: 1 • Supplied sterile
7F
MYLERTM LUMEN ELECTRODE CATHETERS7 FRENCH
MYLERTM Lumen Electrode CatheterNote: Catheter has adapter for protected pin connection
Catalog French Lumen Number Size Length
001517P 7F 125cm�CVP = Central Venous Pressure
• Ideal for pressure monitoring and sampling from the vena cava or the right atrium while
simultaneously pacing the ventricular apex • Woven open lumen construction with 2mm
electrodes and side holes; Side holes are placed 10cm from tip • First electrode: distal tip
• Second electrode: 1cm proximal • Single use only • Items per box: 1 • Supplied sterile
7F
CVP�/PACING LUMEN ELECTRODE CATHETERS7 FRENCH
Catalog French Lumen Number Size Length
002921P 7F 125cm
• Ideal for coronary sinus sampling while simultaneously pacing the right atrium
• Woven open lumen construction with 2mm electrodes and distal side holes
• First electrode: 1.5cm from distal tip • Second electrode: 1cm proximal
from first electrode • Single use only • Items per box: 1 • Supplied sterile
7F
GORLINTM LUMEN ELECTRODE CATHETERS7 FRENCH
Temporary Pacing Electrodes
79
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
GORLINTM Lumen Electrode CatheterNote: Catheter has adapter for protected pin connection
CVP/Pacing Lumen Electrode CatheterNote: Catheter has adapter for protected pin connection
80
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
EP Systems
LABSYSTEMTM PRO EP RECORDING SYSTEMSophistication Made Simple
The LABSYSTEMTM PRO EP Recording System is an integrated, dual-monitor electrophysiologyrecording system. It enables the electrophysiologist to monitor, record, analyze, and print data gathered during an electrophysiology study.
Continued Excellence for Your Evolving EP Lab Needs
• Hardware and software upgrades for added flexibility on this platform
• Superior electrogram signal processing and analysis
• Customizable layout and procedure flow
• Waveform export in a variety of raw and image formats: ASCII, Binary, JPG, and BMP
• Enhancements to user interface for improved patient assessment
• Clinical EP expertise designed into every product and feature
• Exceptional warranty and service options available for peace of mind
• Dedicated clinical and technical specialists for support and training
LABLINK DATA INTERFACEOne connection...brings the entire story to life
The LabLink Data Interface synchronizes and integrates CARTO® 3 System 3D mapping capabilities with the power of the LABSYSTEMTM PRO EP Recording System. With a single connection, the LabLink Data Interface allows selection of stimulation channels from eitherthe recording or the mapping system. Patient demographics, 3D image snapshots and eventdata are all seamlessly merged to help improve lab productivity and enhance reporting capabili-ties.
Features
• Synchronization of mapping points and waveforms
• Share patient demographics between LABSYSTEMTM PRO EP Recording System andCARTO® 3 System
• Single repository for recording, mapping and stimulation information
• Select stimulation channels on either system
• Direct connect cables
• Service and support
81
Contact Your Local Representative for Product Availability: 1-800-824-8724
EP RecordingSystem
Products Not Approved or Available in All Geographies.
82
Contact Your Local Representative for Product Availability: 1-800-824-8724
EPLOGIXTM MAPPING AND ANALYSIS SUITESophisticated Mapping and Analysis From a New Point of View
Introducing the EPLOGIXTM Mapping and Analysis Suite—a unique toolset that can help demystify even the most puzzling cases. Based on the proven signal quality of our LABSYSTEMTM PRO EP Recording System, the Enhanced Module with ELECTROVIEWTM
3D Mapping software offers you a whole new approach to electrogram analysis with time and frequency domain algorithms and 3D visualization.
EPLOGIXTM Mapping and Analysis Suite with ELECTROVIEWTM 3D Mapping Software
• Features advanced analysis algorithms with no additional cost or set-up time
• Provides multiple mapping capabilities: activation timing, voltage thresholds, and dominant frequency
• Includes additional FFT analysis, AF cycle length, and VT template matching advanced algorithms
• Helps you capture and track information quickly and easily throughout procedures
• Captures quick, single-beat data from multi-pole catheters
• Complements current mapping techniques with electrogram-based analysis
• Works seamlessly with our new Enhanced Visualization and Fluoro Capture Option, to help track your catheter location during mapping procedures.
• Activated by a BARD® EP catheter
CLEARSIGNTM AMPLIFIER
Bard’s new CLEARSIGNTM Amplifier provides unmatched signal quality and intuitive design for improved efficiency and accuracy during your electrophysiology procedure.
• Superior signal clarity
• High-resolution 16-bit A/D converter
• Exceptional signal processing
• Intracardiac (IC) catheter, surface ECG, BP, and other instrumentation inputs
• RF blocking filters
• Unique adaptive noise filters
• Notch filters at both 50 & 60 Hz
• Available on any individual IC, ECG, or Stim channel
• Map larger areas in the endocardium
• Flexibility for future technology
• Easily program IC inputs, ranges, and filters on any channel
• Dedicated stimulus detection channels simplify configuration
• Ease of use and flexibility to benefit all lab staff
Best-in-classWaveform Output and
Display
UnparalleledNoise Rejection
Up to 160 BipolarIC Channels
Intuitive Configuration
and Setup
EP Systems
Products Not Approved or Available in All Geographies.
TECHNOLOGYCLEARSIGNTM
EP Systems
EP REVIEW WORKSTATION
The LABSYSTEMTM PRO Review Workstation is an extension to the LABSYSTEMTM PRO EPRecording System product line that allows review, analysis,and report generation of recorded patient data without beingphysically connected to the main clinical system. It may be used in remote locations outside of the lab such as the physician’s office, home, or during travel. Ask yourTerritory Manager about availability.
IMAGE CAPTURE (FLUORO)Image Capture option allows you to capture analog and VGA digital fluoroscopy images and cine loops for integration in your patient data report providing a better assessment for patient diagnosis.
REPORT GENERATOREnhanced Report Generator seamlessly creates a professional and informative patient record by automatically capturing user-defined study log information into a customizable template. Waveforms and fluoroscopy images can also be included to deliver the most complete picture of the patient’s diagnosis and treatment.
EPLINKTM HOSPITAL INFORMATION SYSTEM INTERFACE (H.I.S./HL7)The Hospital Information System Interface option allows bi-directional communications toHospital Information Systems and Cardiovascular Information Systems utilizing the HL7 protocol. This interface allows data such as patient demographic (ADT) and/or Orders data to be imported into the LABSYSTEMTM PRO EP Recording System, and study results to be exported to the hospital’s central information system. The final results will be in the form of a summary report in PDF, Doc, or HTML format.
REMOTE MONITORINGSelect from several remote monitor setups to meet your EP lab design needs.
RF GENERATOR INTERFACE CABLESDepending on your RF generator, the BARD® LABSYSTEMTM PRO EP Recording System interfaces effortlessly to provide ablation information during the study and in the study reports. Select which cable fits your model.
Additional Options for Your EP Lab
83
Contact Your Local Representative for Product Availability: 1-800-824-8724
EP RecordingSystem
Products Not Approved or Available in All Geographies.
Catalog Quantity Number Needed Description
LABSYSTEMTM PRO Base Components2001994 1 LS8900 Computer with LABSYSTEMTM PRO System Software V2.4A2001205 1 Isolation Transformer (U.S.)2001297 1 Isolation Transformer (International)2001240 1 Isolation Transformer (Japan)2001155 2 Blood Pressure Transducer Kit (5/bx)200467 2 Blood Pressure Cables200399 1 BNC Male to Phono Male Cable for connection to Stimulator2001001 1 ECG Leadwire Cable 10,36 IEC2001077 1 Power Cord200394 1 Shorting Pins for ECG cable (5/pk)2001214 1 DVD Storage Media (5/pk)2001230 1 RF Filter Module200690 1 Power Cord
Monitors2001977 2 21" LCD Flat Panel Monitor2001961 2 24" LCD Flat Panel Monitor
Printer2001942 1 HP LaserJet Black & White Printer200258 1 Printer Interface Cable
LabLink Data Interface 2002011 1 LABSYSTEMTM PRO EP Recording System Software v.2.6a*2002013 1 LABSYSTEMTM PRO EP Recording System Software v2.6a with 3m Cable**2002015 1 LABSYSTEMTM PRO EP Recording System Software v2.6a with 6m Cable**2002016 1 LABSYSTEMTM PRO EP Recording System Software v2.6a - LabLink Software License Key
CLEARSIGNTM Amplifier & Cables
CLEARSIGNTM Amplifier2001268 1 Channels 402001267 1 Channels 802001266 1 Channels 1202001232 1 Channels 160
Ethernet Interface Cable2001271 1 Length 10ft.2001274 1 Length 25ft.2001272 1 Length 50ft.2001273 1 Length 100ft.
Analog Output Cable2001263 1 Length 3M2001264 1 Length 6M2001265 1 Length 15M
Analog Input Cable2001259 1 Length 1M
LABSYSTEMTM PRO EP RECORDING SYSTEM COMPONENTS LIST
EP Systems
84
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
* Software only.** NOTE: Contains one IC cable, one ECG
cable, and one stim adapter cable.
Catalog Quantity Number Needed Description
Stimulator Input Cable2001253 1 Length 3M2001254 1 Length 6M2001255 1 Length 15M
CLEARSIGNTM Junction Box and Cable (One junction box per 40 channels of the CLEARSIGNTM Amplifier)2001250 1/Module Length 3M2001251 1/Module Length 6M2001252 1/Module Length 15M
Bed Rail Bracket2001413 1 For Seimens (and most other) Beds2001388 1 Junction Box Support Bracket
ECG Cable2001328 1 ECG CABLE, IEC, CLEARSIGNTM, 3 METERS2001329 1 ECG CABLE, IEC, CLEARSIGNTM, 6 METERS2001330 1 ECG CABLE, IEC, CLEARSIGNTM, 15 METERS
LABSYSTEMTM PRO EP RECORDING SYSTEM OPTIONAL COMPONENTS LIST
Catalog Quantity Number Needed Description
Image Capture Kit (FLUORO/VGA)2001953 1 Image Capture Kit
Report Generator2001400 1 Report Generator Software
RF Generator Interface CablesRS-232 Cable for Boston Scientific’s EPT, Medtronic’s Atakr and Atakr II, St. Jude MedicalTM IBI-1500 T9 and T11, and Osypka Generators2001177 1 Length 25ft.2001178 1 Length 50ft.2001179 1 Length 100ft.
Null Modem Cable for Biosense Webster’s Stockert Generator2001180 1 Length 25ft.2001181 1 Length 50ft.2001182 1 Length 100ft.
EPLOGIXTM Mapping and Analysis Suite2001960 1 Mapping and Analysis Suite with ELECTROVIEWTM 3D Mapping Software
IBI Ablation Generator2001984 1 IBI Ablation Generator Software
LABSYSTEMTM PRO EP RECORDING SYSTEM COMPONENTS LIST
EP Systems
EP RecordingSystem
85
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Quantity Number Needed Description
Remote Monitor OptionsLCD Remote Splitter Kit (Permits remote viewing of both screens in the lab)2001432 1 Video Splitter 120v- VGA 2001434 1 SVGA Cable, M-M, 50ft.2001435 1 SVGA Cable M-M 100ft.
Monitor 2001977 1 21" LCD Flat Panel Monitor2001961 1 24" LCD Flat Panel Monitor
ENSITETM NavX Interface Kit 2001404 1 Cable, Ext, CLEARSIGNTM 2.4m 2001405 1 Cable, Ext, ESI NavX A 1.2m2001406 1 Cable, Ext, ESI NavX B 1.2m 2001414 1 Cable, Ext, CLEARSIGNTM 6m2001407 1 CLEARSIGNTM to ENSITETM NavX Interconnection Port
System Cart200449 1 System Cart
EPLINKTM Hospital Information System Interface2001410 1 EPLINKTM H.I.S. Connectivity Software
EP Review Workstation2001327 1 EP Review Workstation Software
Miscellaneous Cables/Components2001217 1 BNC Male-to-Male 30Ft.2001077 1 Radiotranslucent ECG Leadwires2001183 2 Female to Female BNC Barrel Adaptors (5/pb)
LABSYSTEMTM PRO CLEARSIGNTM to CARTO® 3 Quick Connect Kits2001971 2 Quick Connect Cable Kit (3m)2001976 2 Quick Connect Cable Kit (6m)2001970 1 CLEARSIGNTM Amplifier to CARTO® 3 System Quick Connect Stimulator Adaptor Cable (Standard Length)2001975 1 CLEARSIGNTM Amplifier to CARTO® 3 System Quick Connect ECG Cable (6m)2001974 1 CLEARSIGNTM Amplifier to CARTO® 3 System Quick Connect IntraCardiac Cable (6m)2001968 1 CLEARSIGNTM Amplifier to CARTO® 3 System Quick Connect ECG Cable (3m)2001969 1 CLEARSIGNTM Amplifier to CARTO® 3 System Quick Connect IntraCardiac Cable (3m)
LABSYSTEMTM PRO EP RECORDING SYSTEM OPTIONAL COMPONENTS LIST
EP Systems
86
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
EP Systems
MICROPACE STIMLABTM DUAL TOUCH STIMULATION SYSTEM
Build on the comprehensive and intuitive EPS320 cardiac stimulator, the unique STIMLABTM Dual Touch Stimulation System puts control of stimulation inthe hands of the EP physician. No need to break sterility to activate stimulationprotocols or change stim settings. The bedside touch screen interface duplicatesall the controls of the desk-top monitor but puts them in easy reach of the patient bedside. Save time and minimize confusion by putting stimulator controlin the hands of the physician.
STIMCORTM THE INTEGRATE-ABLE EP STIMULATOR FOR TOMORROW’S EP LAB
• Allows for sleek, uncluttered workspace.• Option for bedside onscreen display.• Latest ‘cockpit’ style integrated design.• Pre-wired integrated cabling for easy install.• Easy touch screen and number pad control.• Customize to any sized EP laboratory.
MICROPACE EPS320 CARDIAC STIMULATOR WITH TOUCH SCREEN INTERFACE
Designed by a practicing electrophysiologist, this comprehensive, computer-basedcardiac stimulator meets all of your EP study requirements. It can be used forrefractory measurements, initiation and termination of tachyarrhythmias andmeasurements of electrical conduction properties of the heart. Pacing outputs,
rates and premature impulses can be adjusted for each EP case study.
The intuitive touch screen gives the user access to all measurements and cardiac stimulation controls quickly and easily. The screen provides a user-friendly interface that can shorten thelearning curve and build user confidence. Comprehensive on-line tutorials support user training.
The Control. The Power.
The Response.
87
Contact Your Local Representative for Product Availability: 1-800-824-8724
CardiacStimulator
Products Not Approved or Available in All Geographies.
88
Contact Your Local Representative for Product Availability: 1-800-824-8724
MICROPACE TOUCH SCREEN INTERFACE
The comprehensive, computer-based cardiac stimulator that meets all of your EP study requirements is now even easier to use. With its intuitive interface, theMicroPace EPS320 Cardiac Stimulator offers an array of improvements.
The Touch Screen puts full control of cardiac stimulation in the hands of the EP physician at the patient bedside, freeing up staff to run the recording systemand perform other tasks during the EP study.
Visual controls on the touch screen providea user-friendly interface that can shorten the learning curve and build user confidence. On-line diagrams support user training.
Proprietary software is upgradeable to keeppace with changing EP procedure needs.
A clinical understanding of EP requirements is built into every product.
PATIENT CONNECTION 4-CHANNEL STIMULUS MULTIPLEXER BOX
The 4-Channel Stimulus Multiplexer box is a state-of-the-art addition to the MicroPace family of products offered by BARD®. It provides additional outputchannels and intuitive programming for virtual 4-channel pacing operation. It is compatible with all 4 stim-channel amplifiers (including the CLEARSIGNTM
Amplifier) and offers a special bi-ventricular pacing protocol. Additionally, it offers improved filtering, safety, and automatic software recognition features.
Additional Options for
Your EP Lab
EP Systems
Products Not Approved or Available in All Geographies.
Bedside Stimulation
Easy to Learnand Use
Upgradeable
Designed by aPracticing EP
Catalog Quantity Number Needed Description
MicroPace STIMLABTM Bedside Cardiac Stimulator ControlAll Required Components200MP3171 1 STIMLABTM Computer Cabinet200MP3172 1 STIMLABTM Cardiac Stimulator SGU200MP3173 1 STIMLABTM Remote Touch Screen200MP3174 1 STIMLABTM Local Touch Screen200MP3183 1 Roll Stand Package
MicroPace STIMCORTM Compact Cardiac StimulatorAll Required Components200MP3343 1 STIMCORTM Computer Cabinet Package200MP3172 1 STIMCORTM Stimulus Generator Unit (SGU)200MP3113B 1 MicroPace Touch Screen Monitor
Optional STIMCORTM Component200MP3403 1 10 Meter Local Display Kit
MicroPace EPS320 Stimulator200MP3102 1 MicroPace EPS320 Cardiac Stimulator
Components Included 1 Stimulus Generator Unit (SGU) 1 Power Supply for SGU 1 Bona Lite PC 1 High Power Supply for Bona Lite 1 Isolation Transformer (U.S.) 1 Power Cable for Isolation Transformer 1 RS-232 Serial Cable, 3ft (includes RF Suppression) 1 Power Cable from Isolation transformer to SGU (U.S.) 2 Power Cable for Transformer Out to Power Boxes (U.S.) 2 Phono and Phono Cable 1 Patient Connection Stimulus Junction Box 2-Channel with RF Filters 1 Keyboard
MicroPace Touch Screen Monitor200MP3113B 1 MicroPace ELO Touch Screen Display Monitor Kit
Components Included 1 ELO Touch Screen Monitor 1 CF Card with proprietary software 1 RS-232 serial cable PC to Touch Screen, 2M 1 Power Cable 1 Speaker Cable, 2M 1 Video Cable, 2M
MICROPACE CARDIAC STIMULATOR COMPONENTS LIST
EP Systems
CardiacStimulator
89
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
90
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Quantity Number Needed Description
Patient Connection 4 Channel Stimulus Multiplexer Junction Box and Cable200MP3091 1 Patient Connection 4 Channel Stimulus Multiplexer Junction Box and Cable200MP3090 1 SmBox Extension Control Cable 15M (RS232)
Optional ComponentsMP307017 1 Stimulus Extension Cable 12M (for 2-channel) 2001177 1 RS-232 Cable Male to Female SGU to PC Length 25ft.2001178 1 RS-232 Cable Male to Female SGU to PC Length 50ft.2001179 1 RS-232 Cable Male to Female SGU to PC Length 100ft.200MP3393 1 Compact Numeric Keypad for Version 3.21 Software200MP3385 1 STIMLABTM Upgrade Kit for EPS320200MP3098 1 System Computer Bona Light PC200MP3074 1 Powerbox 15.0VDC 2.4A Power Supply of SGU200MP3089 1 SMBox Control Cable Standard200MP3016 1 EPS320 Keyboard MP3016
EP Systems
EP Systems
WARRANTYBARD® protects your equipment purchase for up to 12 months after purchase. After that time, your equipment can be covered by an extendedservice agreement. BARD® is prepared to provide the service and support you need to keep your lab running.
EXTENDED SERVICE PORTFOLIOBARD® is a company rich in history, with a tradition of commitment to quality products, service, and customers and patients we serve. While always working towards delivering advanced health care solutions, we will continue to pursue technological developments that embody quality,integrity, and service for superior clinical benefits while helping to loweroverall costs. The BARD® Service Portfolio provides a range of options to meet your ever-changing hospital needs. Based on your clinical and financial objectives, choose from one of the following catered solutions.
PresidentialThe Presidential option provides unparalleled response and coverage, along with the clinical support you need to effectively grow your lab bothtechnically and financially. The added value of this offer differentiates itfrom our other options by ensuring that you receive the highest level of service available.
ExecutiveThe Executive option allows you to maximize your technical potential while optimizing your long term investment. The plan provides technologyprotection with software and hardware updates, assurance of consistent and predictable rates, and extended coverage hours.
PartnershipThe Partnership option offers a reassuring collaboration for the cost-conscious customer. Working together to guarantee your equipment performance and reliability, you can feel confident that your patient care is never compromised.
With a rich history and many
years of experience focusing
on electrophysiology,
Bard Electrophysiology
continues to develop
products for users, by users.
From recording systems and
cardiac stimulators to
catheters and accessories,
Bard Electrophysiology
offers an array of solutions.
Please contact your BARD® EP
Territory Manager for more
information on our full line of
EP products and services:
(800) 282-1332.
91
Contact Your Local Representative for Product Availability: 1-800-824-8724
EquipmentProtection
Products Not Approved or Available in All Geographies.
Catalog Quantity Number Needed Description
Extended Service Agreements200330 1 Presidential200330 1 Executive200330 1 Partnership
Additional Training Per Day200540 1 Out of Warranty Service
Ask your Territory Manager about options for your specific service and support needs.
EQUIPMENT PROTECTION
EP Systems
92
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Customer Service
93
Contact Your Local Representative for Product Availability: 1-800-824-8724
Services
Products Not Approved or Available in All Geographies.
SERVICES
Bard Electrophysiology is located in suburban Lowell, Massachusetts,30 miles Northwest of Boston. For close to fifty years, our dedicated employees in Research and Development, Quality, Marketing, Human Resources, Finance, Regulatory/Clinical, Sales/Administration, and Customer Service, have all strived to work together to bring the finest quality electrophysiologyproducts and service to hospitals, electrophysiologists and patients worldwide.
Bard Electrophysiology DivisionC.R. Bard, Inc.55 Technology DriveLowell, MA 01854
Orders may be placed by telephone, fax, mail or EDI: Customer Service – Phone: 800-824-8724 Fax: 877-281-1492EDI (Electronic Data Interchange): [email protected]
Systems Hotline Support for US Customers: 800-872-3527 7:00AM – 9:00PM EST
Bard Electrophysiology DivisionC.R. Bard, Inc.PO Box 75767Charlotte, NC 28275
Prices: Subject to change without prior notice; all applicable taxes will becharged. Payments: Net 30 days – Freight FOB Origin
Unless otherwise specified, all orders are shipped via two day delivery. Although BARD® is not responsible for shipping damage to the product, BARD®
will extend assistance to settle claims with the carrier for product damaged in transit. All merchandise should be inspected upon arrival and any shippingdamage reported to the carrier. Proof of deliveries can be obtained up to 90 days from date of shipment.
Contact Information
About Us
Ordering Information
Remit Payment to
Technical Support
Delivery
Terms
Unless a product is covered by a separate warranty or a separate warranty is enclosed with the product, the following Limited Product Warranty will apply to the product:
The product is warranted to the original purchaser to be free from defects in material and workmanship for a period of one (1) year from the date of purchase. If the product proves to be defective, purchaser may return same to Bard Electrophysiology for repair or replacement, at Bard Electrophysiology’s option. The liability of Bard Electrophysiology under this limited warranty does not extend to any abuse or misuse of the product.
This limited product warranty is in lieu of all other warranties, whether expressed or implied, including any warranty of merchantability or fitness for a particular purpose.
Because the storage and use of any product are factors beyond the control of Bard Electrophysiology and may directly affect it and the results obtainedfrom it, the liability and remedy stated in this limited warranty will be the sole liability of Bard Electrophysiology and remedy available to purchaser for a product, whether in contract, tort (including negligence) or otherwise, and Bard Electrophysiology will not be liable to purchaser for incidental and consequential damages arising from its use.
Warranty and Service Agreements are provided for BARD® EP Systems components. See that section for more information.
To obtain Return Authorizations for the return of unused, saleable merchandise, other than capital equipment or a performance claim, contact Customer Service at (800) 824-8724.
To expedite the return process, please have on hand the following information:
• Purchase order number, Bard Electrophysiology invoice number and date of the invoice.
• Catalog number and quantity to be returned.
• Reason for return (e.g., duplicate order)
Returned products must be:
• Standard catalog items received by Bard Electrophysiology within 90 days of invoice date.
• Received in an unused and saleable condition.
• Previously authorized by Bard Electrophysiology.
Your customer account will be credited for acceptable returned products subjectto a restocking fee of 30%, minimum of $10. Merchandise processed in errorby Bard Electrophysiology will be credited 100%.
Return Goods Policy
94
Contact Your Local Representative for Product Availability: 1-800-824-8724
Warranty and Service Agreements
Limited ProductWarranty
Customer Service
Products Not Approved or Available in All Geographies.
Customer Service
95
Contact Your Local Representative for Product Availability: 1-800-824-8724
Services
Products Not Approved or Available in All Geographies.
Field Assurance will assist you with product related complaints. Contact Field Assurance at (800) 392-9201. Any product with a performance related problem may be returned to us. Please have on hand the following information to return product:
1. Purchase order number, BARD® invoice and date.
2. Catalog number and quantity to be returned.
3. Manufacturing lot number and sterile lot number.
4. Nature of problem.
Please clean and package used devices carefully. We appreciate your assistancein preparing products for examination by rinsing away blood and bodily fluidsand by disinfecting the product. When you request to return a product, we will assign you an authorization number and we will mail you the materialsneeded to return the product.
All products and specifications set forth in the current catalog are based on information available at the time of publication. BARD® reserves the right to discontinue any product, modify specifications, or change prices with or without prior notification.
Complaints
Disclaimer
96
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
001517P . . . . . . . . . . . . . . . .79002853S . . . . . . . . . . . . . . . . .35002921P . . . . . . . . . . . . . . . .79002943S . . . . . . . . . . . . . . . . .39002944S . . . . . . . . . . . . . . . . .39004019P . . . . . . . . . . . . . . . .34004020P . . . . . . . . . . . . . . . .34004178P . . . . . . . . . . . . . . . .41006172P . . . . . . . . . . . . . . . .77006173P . . . . . . . . . . . . . . . .77006221P . . . . . . . . . . . . . . . .76006225P . . . . . . . . . . . . . . . .76006241P . . . . . . . . . . . . . . . .76006242P . . . . . . . . . . . . . . . .76006245S . . . . . . . . . . . . . . . . .39006395P . . . . . . . . . . . . . . . .74006590P . . . . . . .41, 42, 43, 44006792P . . . . . . . . . . . . . . . .39006798P . . . . . . . . . . . . . . . .39007150P . . . . . . . . . . . . . . . .74007151P . . . . . . . . . . . . . . . .74007152P . . . . . . . . . . . . . . . .74007153P . . . . . . . . . . . . . . . .74007154P . . . . . . . . . . . . . . . .74007155P . . . . . . . . . . . . . . . .74007156P . . . . . . . . . . . . . . . .74007157P . . . . . . . . . . . . . . . .74007250P . . . . . . . . . . . . . . . .74007253P . . . . . . . . . . . . . . . .74007406P . . . . . . . . . . . . . . . .74007417P . . . . . . . . . . . . . . . .74008153P . . . . . . . . . . . . . . . .76008154P . . . . . . . . . . . . . . . .76008556P . . . . . . . . . . . . . . . .77008568P .34, 35, 36, 38, 40, 44008635P . . . . . . . . . . . . . . . .77051510P . . . . . . . . . . . . . . . .78051511P . . . . . . . . . . . . . . . .78051512P . . . . . . . . . . . . . . . .78051513P . . . . . . . . . . . . . . . .78054015P . . . . . . . . . . . . . . . .78057152P . . . . . . . . . . . . . . . .75057153P . . . . . . . . . . . . . . . .75057156P . . . . . . . . . . . . . . . .75057157P . . . . . . . . . . . . . . . .75057406P . . . . . . . . . . . . . . . .75100013 . . . . . . . . . . . . . . . . . . .6100014 . . . . . . . . . . . . . . . . . . .6100015 . . . . . . . . . . . . . . . . . . .6100016 . . . . . . . . . . . . . . . . . . .6100323 . . . . . . . . . . . . . . . . . . .6103050 . . . . . . . . . . . . . . . . . . .6
105229 . . . . . . . . . . . . . . . . . . .6105247 . . . . . . . . . . . . . . . . . . .6105265 . . . . . . . . . . . . . . . . . . .6105327 . . . . . . . . . . . . . . . . . . .6161601 . . . . . . . . . . . . . . . . . .58161602 . . . . . . . . . . . . . . . . . .58161603 . . . . . . . . . . . . . . . . . .58191001 . . . . . . . . . . . . . . . . . .34200055P . . . . . . . . . . . . . . . .37200056 . . . . . . . . . . . . . . . . . .36200056E . . . . . . . . . . . . . . . .36200057P . . . . . . . . . . . . . . . .37200058 . . . . . . . . . . . . . . . . . .36200058E . . . . . . . . . . . . . . . .36200059P . . . . . . . . . . . . . . . .37200060 . . . . . . . . . . . . . . . . . .36200060E . . . . . . . . . . . . . . . .36200061P . . . . . . . . . . . . . . . .37200062E . . . . . . . . . . . . . . . .36200063P . . . . . . . . . . . . . . . .37200064P . . . . . . . . . . . . . . . .37200066S . . . . . . . . . . . . . . . . .39200070S . . . . . . . . . . . . . . . . .35200076P . . . . . . . . . . . . . . . .44200077P . . . . . . . . . . . . . . . .44200078P . . . . . . . . . . . . . . . .44200085P . . . . . . . . . . . . . . . .41200088P . . . .28, 30, 31, 34, 36, . . . . . . . . . . . . . . . . . . . . . .37, 45200089P . . . .28, 31, 40, 41, 452001001 . . . . . . . . . . . . . . . . .842001077 . . . . . . . . . . . . . .84, 862001123 . . . . . . . . . . . . . . . . .372001155 . . . . . . . . . . . . . . . . .842001177 . . . . . . . . . . . . . .85, 902001178 . . . . . . . . . . . . . .85, 902001179 . . . . . . . . . . . . . .85, 902001180 . . . . . . . . . . . . . . . . .852001181 . . . . . . . . . . . . . . . . .852001182 . . . . . . . . . . . . . . . . .852001183 . . . . . . . . . . . . . . . . .862001205 . . . . . . . . . . . . . . . . .842001214 . . . . . . . . . . . . . . . . .842001217 . . . . . . . . . . . . . . . . .862001230 . . . . . . . . . . . . . . . . .842001232 . . . . . . . . . . . . . . . . .842001240 . . . . . . . . . . . . . . . . .842001250 . . . . . . . . . . . . . . . . .852001251 . . . . . . . . . . . . . . . . .852001252 . . . . . . . . . . . . . . . . .852001253 . . . . . . . . . . . . . . . . .852001254 . . . . . . . . . . . . . . . . .85
2001255 . . . . . . . . . . . . . . . . .852001259 . . . . . . . . . . . . . . . . .842001263 . . . . . . . . . . . . . . . . .842001264 . . . . . . . . . . . . . . . . .842001265 . . . . . . . . . . . . . . . . .842001266 . . . . . . . . . . . . . . . . .842001267 . . . . . . . . . . . . . . . . .842001268 . . . . . . . . . . . . . . . . .842001271 . . . . . . . . . . . . . . . . .842001272 . . . . . . . . . . . . . . . . .842001273 . . . . . . . . . . . . . . . . .842001274 . . . . . . . . . . . . . . . . .842001285 . . . . . . . . . . . . . . . . .202001291 . . . . . . . . . . . . . . . . .202001292 . . . . . . . . . . . . . . . . .202001297 . . . . . . . . . . . . . . . . .842001298 . . . . . . . . . . . . . . . . .712001299 . . . . . . . . . . . . . . . . .71200131 . . . . . . . . . . . . . . . . . .302001327 . . . . . . . . . . . . . . . . .862001328 . . . . . . . . . . . . . . . . .852001329 . . . . . . . . . . . . . . . . .852001330 . . . . . . . . . . . . . . . . .852001335 . . . . . . . . . . . . . . . . .202001388 . . . . . . . . . . . . . . . . .852001398 . . . . . . . . . . . . . .18, 712001400 . . . . . . . . . . . . . . . . .852001404 . . . . . . . . . . . . . . . . .862001405 . . . . . . . . . . . . . . . . .862001406 . . . . . . . . . . . . . . . . .862001407 . . . . . . . . . . . . . . . . .862001408 . . . . . . . . . . . . . . . . .202001409 . . . . . . . . . . . . . . . . .202001410 . . . . . . . . . . . . . . . . .862001413 . . . . . . . . . . . . . . . . .852001414 . . . . . . . . . . . . . . . . .862001432 . . . . . . . . . . . . . . . . .862001434 . . . . . . . . . . . . . . . . .862001435 . . . . . . . . . . . . . . . . .862001498 . . . . . . . . . . . . . . . . .712001499 . . . . . . . . . . . . . . . . .71200150 . . . . . . . . . . . . . . . . . .35200151 . . . . . . . . . . . . . . . . . .35200152 . . . . . . . . . . . . . . . . . .35200153 . . . . . . . . . . . . . . . . . .352001942 . . . . . . . . . . . . . . . . .842001953 . . . . . . . . . . . . . . . . .852001958 . . . . . . . . . . . . . . . . .202001960 . . . . . . . . . . . . . . . . .852001961 . . . . . . . . . . . . . .84, 862001968 . . . . . . . . . . . . . . . . .862001969 . . . . . . . . . . . . . . . . .86
Index
97
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Number Page Catalog Number Page Catalog Number Page
98
Contact Your Local Representative for Product Availability: 1-800-824-8724
Index
Products Not Approved or Available in All Geographies.
2001970 . . . . . . . . . . . . . . . . .862001971 . . . . . . . . . . . . . . . . .862001974 . . . . . . . . . . . . . . . . .862001975 . . . . . . . . . . . . . . . . .862001976 . . . . . . . . . . . . . . . . .862001977 . . . . . . . . . . . . . .84, 862001984 . . . . . . . . . . . . . . . . .852001994 . . . . . . . . . . . . . . . . .842002011 . . . . . . . . . . . . . . . . .842002013 . . . . . . . . . . . . . . . . .842002015 . . . . . . . . . . . . . . . . .842002016 . . . . . . . . . . . . . . . . .84200201S . . . . . . . . . . . . . . . . .39200203S . . . . . . . . . . . . . . . . .39200204 . . . . . . . . . . . . . . . . . .41200204E . . . . . . . . . . . . . . . .41200205 . . . . . . . . . . . . . . . . . .41200205E . . . . . . . . . . . . . . . .41200206 . . . . . . . . . . . . . . . . . .41200207 . . . . . . . . . . . . . . . . . .41200208 . . . . . . . . . . . . . . . . . .41200209 . . . . . . . . . . . . . . . . . .42200210 . . . . . . . . . . . . . . . . . .42200211 . . . . . . . . . . . . . . . . . .43200212 . . . . . . . . . . . . . . . . . .43200258 . . . . . . . . . . . . . . . . . .84200330 . . . . . . . . . . . . . . . . . .92200344 . . . . . . . . . . . . . . . . . .30200354 . . . . . . . . . . . . . . . . . .42200355 . . . . . . . . . . . . . . . . . .43200394 . . . . . . . . . . . . . . . . . .84200399 . . . . . . . . . . . . . . . . . .84200449 . . . . . . . . . . . . . . . . . .86200467 . . . . . . . . . . . . . . . . . .84200472 . . . . . . . . . . . . . . . . . .38200473 . . . . . . . . . . . . . . . . . .38200540 . . . . . . . . . . . . . . . . . .92200567 . . . . . . . . . . . . . . . . . .43200568 . . . . . . . . . . . . . . . . . .43200570P . . . . . . . . . . . . . . . .39200571P . . . . . . . . . . . . . . . .39200572P . . . . . . . . . . . . . . . .39200573 . . . . . . . . . . . . . . . . . .34200574 . . . . . . . . . . . . . . . . . .37200575 . . . . . . . . . . . . . . . . . .41200576 . . . . . . . . . . . . . . . . . .43200577 . . . . . . . . . . . . . . . . . .36200577E . . . . . . . . . . . . . . . .36200578 . . . . . . . . . . . . . . . . . .37200579P . . . . . . . . . . . . . . . .41200580 . . . . . . . . . . . . . . . . . .36200580E . . . . . . . . . . . . . . . .36
200581 . . . . . . . . . . . . . . . . . .36200581E . . . . . . . . . . . . . . . .36200582 . . . . . . . . . . . . . . . . . .38200583 . . . . . . . . . . . . . . . . . .37200584 . . . . . . . . . . . . . . . . . .37200585 . . . . . . . . . . . . . . . . . .38200586 . . . . . . . . . . . . . . . . . .37200587 . . . . . . . . . . . . . . . . . .36200587E . . . . . . . . . . . . . . . .36200588 . . . . . . . . . . . . . . . . . .36200588E . . . . . . . . . . . . . . . .36200589 . . . . . . . . . . . . . . . . . .38200590 . . . . . . . . . . . . . . . . . .37200591 . . . . . . . . . . . . . . . . . .37200592 . . . . . . . . . . . . . . . . . .38200593 . . . . . . . . . . . . . . . . . .37200594 . . . . . . . . . . . . . . . . . .40200595 . . . . . . . . . . . . . . . . . .43200596 . . . . . . . . . . . . . . . . . .45200597 . . . . . . . . . . . . . . . . . .45200598 . . . . . . . . . . . . . . . . . .45200599 . . . . . . . . . . . . . . . . . .45200612P . . . . . . . . . . . . . . . .43200624E . . . . . . . . . . . . . . . .37200624S . . . . . . . . . . . . . . . . .39200690 . . . . . . . . . . . . . . . . . .84200719S . . . . . . . . . . . . . . . . .39200728S . . . . . . . . . . . . . . . . .39200769 . . . . . . . . . . . . . . . . . .28200770 . . . . . . . . . . . . . . . . . .28200771 . . . . . . . . . . . . . . . . . .28200772 . . . . . . . . . . . . . . . . . .28200774P . . . . . . .29, 32, 58, 59200792 . . . . . . . . . . . . . . . . . .38200793 . . . . . . . . . . . . . . . . . .40200794 . . . . . . . . . . . . . . . . . .29200795 . . . . . . . . . . . . . . . . . .29200796 . . . . . . . . . . . . . . . . . .29200797 . . . . . . . . . . . . . . . . . .29200798 . . . . . . . . . . . . . . . . . .29200MP3016 . . . . . . . . . . . . . .90200MP3074 . . . . . . . . . . . . . .90200MP3089 . . . . . . . . . . . . . .90200MP3090 . . . . . . . . . . . . . .90200MP3091 . . . . . . . . . . . . . .90200MP3098 . . . . . . . . . . . . . .90200MP3102 . . . . . . . . . . . . . .89200MP3113B . . . . . . . . . . . . .89200MP3171 . . . . . . . . . . . . . .89200MP3172 . . . . . . . . . . . . . .89200MP3173 . . . . . . . . . . . . . .89200MP3174 . . . . . . . . . . . . . .89
200MP3183 . . . . . . . . . . . . . .89200MP3343 . . . . . . . . . . . . . .89200MP3385 . . . . . . . . . . . . . .90200MP3393 . . . . . . . . . . . . . .90200MP3403 . . . . . . . . . . . . . .89201007 . . . . . . . . . . . . . . . . . .29201009 . . . . . . . . . . . . . . . . . .28201101 . . . . . . . . . . . . . . . . . .32201102 . . . . . . . . . . . . . . . . . .32201103 . . . . . . . . . . . . . . . . . .31201104 . . . . . . . . . . . . . . . . . .31201105 . . . . . . . . . . . . . . . . . .32201106 . . . . . . . . . . . . . . . . . .32201107 . . . . . . . . . . . . . . . . . .32201108 . . . . . . . . . . . . . . . . . .32201109 . . . . . . . . . . . . . . . . . .31201110 . . . . . . . . . . . . . . . . . .31201112 . . . . . . . . . . . . . . . . . .31201113 . . . . . . . . . . . . . . . . . .31201114 . . . . . . . . . . . . . . . . . .31201115 . . . . . . . . . . . . . . . . . .31201116 . . . . . . . . . . . . . . . . . .28201400 . . . . . . . . . . . . . . . . . .36201401 . . . . . . . . . . . . . . . . . .40210001 . . . . . . . . . . . . . . . . . .10210001M . . . . . . . . . . . . . . . .11210001S . . . . . . . . . . . . . . . . .12210001SM . . . . . . . . . . . . . . .13210002 . . . . . . . . . . . . . . . . . .10210002M . . . . . . . . . . . . . . . .11210002S . . . . . . . . . . . . . . . . .12210002SM . . . . . . . . . . . . . . .13210003 . . . . . . . . . . . . . . . . . .10210003M . . . . . . . . . . . . . . . .11210003S . . . . . . . . . . . . . . . . .12210003SM . . . . . . . . . . . . . . .13210004 . . . . . . . . . . . . . . . . . .10210004M . . . . . . . . . . . . . . . .11210004S . . . . . . . . . . . . . . . . .12210004SM . . . . . . . . . . . . . . .13210005 . . . . . . . . . . . . . . . . . .10210005M . . . . . . . . . . . . . . . .11210005S . . . . . . . . . . . . . . . . .12210005SM . . . . . . . . . . . . . . .13210006 . . . . . . . . . . . . . . . . . .10210006M . . . . . . . . . . . . . . . .11210006S . . . . . . . . . . . . . . . . .12210006SM . . . . . . . . . . . . . . .13210007 . . . . . . . . . . . . . . . . . .10210007M . . . . . . . . . . . . . . . .11210007S . . . . . . . . . . . . . . . . .12210007SM . . . . . . . . . . . . . . .13
Catalog Number Page Catalog Number Page Catalog Number Page
210016 . . . . . . . . . . . . . . . . . .10210016M . . . . . . . . . . . . . . . .11210016S . . . . . . . . . . . . . . . . .12210016SM . . . . . . . . . . . . . . .13210017S . . . . . . . . . . . . . . . . .12210018 . . . . . . . . . . . . . . . . . .10210018M . . . . . . . . . . . . . . . .11210018S . . . . . . . . . . . . . . . . .12210018SM . . . . . . . . . . . . . . .13210019 . . . . . . . . . . . . . . . . . .10210019M . . . . . . . . . . . . . . . .11210019S . . . . . . . . . . . . . . . . .12210019SM . . . . . . . . . . . . . . .13210020 . . . . . . . . . . . . . . . . . .10210020M . . . . . . . . . . . . . . . . 11210020S . . . . . . . . . . . . . . . . .12210020SM . . . . . . . . . . . . . . .13210025 . . . . . . . . . . . . . . . . . .10210025M . . . . . . . . . . . . . . . .11210025S . . . . . . . . . . . . . . . . .12210025SM . . . . . . . . . . . . . . .13210026 . . . . . . . . . . . . . . . . . .10210026M . . . . . . . . . . . . . . . .11210026S . . . . . . . . . . . . . . . . .12210026SM . . . . . . . . . . . . . . .13210027 . . . . . . . . . . . . . . . . . .10210027M . . . . . . . . . . . . . . . .11210027S . . . . . . . . . . . . . . . . .12210027SM . . . . . . . . . . . . . . .13210028 . . . . . . . . . . . . . . . . . .10210028M . . . . . . . . . . . . . . . .11210028S . . . . . . . . . . . . . . . . .12210028SM . . . . . . . . . . . . . . .13210029 . . . . . . . . . . . . . . . . . .10210029M . . . . . . . . . . . . . . . .11210029S . . . . . . . . . . . . . . . . .12210029SM . . . . . . . . . . . . . . .13210030 . . . . . . . . . . . . . . . . . .10210030M . . . . . . . . . . . . . . . .11210030S . . . . . . . . . . . . . . . . .12210030SM . . . . . . . . . . . . . . .13210055 . . . . . . . . . . . . . . . .8, 14210055A . . . . . . . . . . . . . .8, 14210057 . . . . . . . . . . . . . . . .8, 14210057A . . . . . . . . . . . . . .8, 14210078M . . . . . . . . . . . . . .8, 14210078MA . . . . . . . . . . . . .8, 14210079A . . . . . . . . . . . . . .8, 14218501S . . . . . . . . . . . . . . . . .12218501SM . . . . . . . . . . . . . . .13218502S . . . . . . . . . . . . . . . . .12218502SM . . . . . . . . . . . . . . .13
218503S . . . . . . . . . . . . . . . . .12218503SM . . . . . . . . . . . . . . .13218504S . . . . . . . . . . . . . . . . .12218504SM . . . . . . . . . . . . . . .13218505S . . . . . . . . . . . . . . . . .12218505SM . . . . . . . . . . . . . . .13218506S . . . . . . . . . . . . . . . . .12218506SM . . . . . . . . . . . . . . .13218507S . . . . . . . . . . . . . . . . .12218507SM . . . . . . . . . . . . . . .13230769 . . . . . . . . . . . . . . . . . .27230770 . . . . . . . . . . . . . . . . . .27230771 . . . . . . . . . . . . . . . . . .27230772 . . . . . . . . . . . . . . . . . .27230794 . . . . . . . . . . . . . . . . . .27230795 . . . . . . . . . . . . . . . . . .27230796 . . . . . . . . . . . . . . . . . .27230797 . . . . . . . . . . . . . . . . . .27230798 . . . . . . . . . . . . . . . . . .27231007 . . . . . . . . . . . . . . . . . .27231009 . . . . . . . . . . . . . . . . . .27231116 . . . . . . . . . . . . . . . . . .27242401 . . . . . . . . . . . . . . . . . .58242402 . . . . . . . . . . . . . . . . . .58242403 . . . . . . . . . . . . . . . . . .58242404 . . . . . . . . . . . . . . . . . .58242405 . . . . . . . . . . . . . . . . . .58242406 . . . . . . . . . . . . . . . . . .58242411 . . . . . . . . . . . . . . . . . .59242412 . . . . . . . . . . . . . . . . . .59242413 . . . . . . . . . . . . . . . . . .59242414 . . . . . . . . . . . . . . . . . .59242415 . . . . . . . . . . . . . . . . . .59242416 . . . . . . . . . . . . . . . . . .59310001T . . . . . . . . . . . . . . . . . .8310002T . . . . . . . . . . . . . . . . . .8310003T . . . . . . . . . . . . . . . . . .8310004T . . . . . . . . . . . . . . . . . .8310005T . . . . . . . . . . . . . . . . . .8310006T . . . . . . . . . . . . . . . . . .8310010T . . . . . . . . . . . . . . . . . .8310011T . . . . . . . . . . . . . . . . . .8310012T . . . . . . . . . . . . . . . . . .8310013T . . . . . . . . . . . . . . . . . .8310014T . . . . . . . . . . . . . . . . . .8310015T . . . . . . . . . . . . . . . . . .8310019T . . . . . . . . . . . . . . . . . .8310020T . . . . . . . . . . . . . . . . . .8310021T . . . . . . . . . . . . . . . . . .8310023T . . . . . . . . . . . . . . . . . .8310024T . . . . . . . . . . . . . . . . . .8320001 . . . . . . . . . . . . . . . . . .57
320002 . . . . . . . . . . . . . . . . . .57320003 . . . . . . . . . . . . . . . . . .57320004 . . . . . . . . . . . . . . . . . .57320005 . . . . . . . . . . . . . . . . . .57320006 . . . . . . . . . . . . . . . . . .57320007 . . . . . . . . . . . . . . . . . .57320008 . . . . . . . . . . . . . . . . . .57320009 . . . . . . . . . . . . . . . . . .57320011G . . . . . . . . . . . . . . . .56320012G . . . . . . . . . . . . . . . .56320013G . . . . . . . . . . . . . . . .56320014G . . . . . . . . . . . . . . . .56320015G . . . . . . . . . . . . . . . .56320016G . . . . . . . . . . . . . . . .56320017G . . . . . . . . . . . . . . . .56320018G . . . . . . . . . . . . . . . .56320019G . . . . . . . . . . . . . . . .56320020G . . . . . . . . . . . . . . . .56320100 . . . . . . . . . . . . . . . . . .24330002 . . . . . . . . . . . . . . . . . .22330050 . . . . . . . . . . . . . . . . . .22330051A . . . . . . . . . . . . . . . .18330053 . . . . . . . . . . . . . . . . . .18330056 . . . . . . . . . . . . . . . . . .18330058 . . . . . . . . . . . . . . . . . .18330059 . . . . . . . . . . . . . . . . . .18330060 . . . . . . . . . . . . . . . . . .18330061 . . . . . . . . . . . . . . . . . .18330062 . . . . . . . . . . . . . . . . . .18330063 . . . . . . . . . . . . . . . . . .18340003 . . . . . . . . . . . . . . . . . .18340013 . . . . . . . . . . . . . . . . . .18390003P . . . . . . . . . . . . .56, 57390004P . . . . . . . . . . . . .56, 57390008P . . . . . . . . . . . . . . . .24400001 . . . . . . . . . . . . . . . . . .47400002 . . . . . . . . . . . . . . . . . .47400003 . . . . . . . . . . . . . . . . . .47400004 . . . . . . . . . . . . . . . . . .47400005 . . . . . . . . . . . . . . . . . .47400006 . . . . . . . . . . . . . . . . . .47400007 . . . . . . . . . . . . . . . . . .47400008 . . . . . . . . . . . . . . . . . .47400009 . . . . . . . . . . . . . . . . . .47400010 . . . . . . . . . . . . . . . . . .47400011 . . . . . . . . . . . . . . . . . .47400012 . . . . . . . . . . . . . . . . . .47400013 . . . . . . . . . . . . . . . . . .48400014 . . . . . . . . . . . . . . . . . .48400015 . . . . . . . . . . . . . . . . . .48400016 . . . . . . . . . . . . . . . . . .48400017 . . . . . . . . . . . . . . . . . .48
Index
99
Contact Your Local Representative for Product Availability: 1-800-824-8724Products Not Approved or Available in All Geographies.
Catalog Number Page Catalog Number Page Catalog Number Page
100
Contact Your Local Representative for Product Availability: 1-800-824-8724
Index
Products Not Approved or Available in All Geographies.
400018 . . . . . . . . . . . . . . . . . .48400019 . . . . . . . . . . . . . . . . . .48400020 . . . . . . . . . . . . . . . . . .48400021 . . . . . . . . . . . . . . . . . .48400022 . . . . . . . . . . . . . . . . . .48400023 . . . . . . . . . . . . . . . . . .49400024 . . . . . . . . . . . . . . . . . .49400025 . . . . . . . . . . . . . . . . . .49400026 . . . . . . . . . . . . . . . . . .49400027 . . . . . . . . . . . . . . . . . .49400028 . . . . . . . . . . . . . . . . . .49400029 . . . . . . . . . . . . . . . . . .49400030 . . . . . . . . . . . . . . . . . .50400031 . . . . . . . . . . . . . . . . . .50400032 . . . . . . . . . . . . . . . . . .50400033 . . . . . . . . . . . . . . . . . .50400034 . . . . . . . . . . . . . . . . . .50400035 . . . . . . . . . . . . . . . . . .50400036 . . . . . . . . . . . . . . . . . .50400037 . . . . . . . . . . . . . . . . . .46400038 . . . . . . . . . . . . . . . . . .46400039 . . . . . . . . . . . . . . . . . .46400040 . . . . . . . . . . . . . . . . . .46400041 . . . . . . . . . . . . . . . . . .47400042 . . . . . . . . . . . . . . . . . .47400043 . . . . . . . . . . . . . . . . . .47400044 . . . . . . . . . . . . . . . . . .47400045 . . . . . . . . . . . . . . . . . .47400046 . . . . . . . . . . . . . . . . . .47400047 . . . . . . . . . . . . . . . . . .47400048 . . . . . . . . . . . . . . . . . .47400050 . . . . . . . . . . . . . . . . . .47400051 . . . . . . . . . . . . . . . . . .47400056 . . . . . . . . . . . . . . . . . .48400057 . . . . . . . . . . . . . . . . . .48400070 . . . . . . . . . . . . . . . . . .50400071 . . . . . . . . . . . . . . . . . .50400074 . . . . . . . . . . . . . . . . . .50400075 . . . . . . . . . . . . . . . . . .50400088 . . . . . . . . . . . . . . . . . .48400090 . . . . . . . . . . . . . . . . . .48400091P . . . . . . . . . . . . . . . .47400092P . . . . . . . . . . . . . . . .46400093P . . . . . . . . . . . . . . . .46400094P . . . . . . . . . . . . . . . .47400096 . . . . . . . . . . . . . . . . . .50400097 . . . . . . . . . . . . . . . . . .50400098 . . . . . . . . . . . . . . . . . .50400099 . . . . . . . . . . . . . . . . . .50400100 . . . . . . . . . . . . . . . . . .50400101 . . . . . . . . . . . . . . . . . .50400102 . . . . . . . . . . . . . . . . . .47400103 . . . . . . . . . . . . . . . . . .50
400104 . . . . . . . . . . . . . . . . . .50400107 . . . . . . . . . . . . . . . . . .50400118 . . . . . . . . . . . . . . . . . .48400119 . . . . . . . . . . . . . . . . . .47400120 . . . . . . . . . . . . . . . . . .47400121 . . . . . . . . . . . . . . . . . .47400122 . . . . . . . . . . . . . . . . . .47400123 . . . . . . . . . . . . . . . . . .47400124 . . . . . . . . . . . . . . . . . .47400501 . . . . . . . . . . . . . . . . . .51400502 . . . . . . . . . . . . . . . . . .51400504 . . . . . . . . . . . . . . . . . .51400505 . . . . . . . . . . . . . . . . . .51400506 . . . . . . . . . . . . . . . . . .51400507 . . . . . . . . . . . . . . . . . .51400508 . . . . . . . . . . . . . . . . . .51400509 . . . . . . . . . . . . . . . . . .51400510 . . . . . . . . . . . . . . . . . .51400511 . . . . . . . . . . . . . . . . . .51400512 . . . . . . . . . . . . . . . . . .51400530 . . . . . . . . . . . . . . . . . .52400531 . . . . . . . . . . . . . . . . . .52400537 . . . . . . . . . . . . . . . . . .51400538 . . . . . . . . . . . . . . . . . .51400539 . . . . . . . . . . . . . . . . . .53400540 . . . . . . . . . . . . . . . . . .53400541 . . . . . . . . . . . . . . . . . .53400542 . . . . . . . . . . . . . . . . . .53400544 . . . . . . . . . . . . . . . . . .53400545 . . . . . . . . . . . . . . . . . .53400546 . . . . . . . . . . . . . . . . . .53400549 . . . . . . . . . . . . . . . . . .54400550 . . . . . . . . . . . . . . . . . .53400551 . . . . . . . . . . . . . . . . . .53400552 . . . . . . . . . . . . . . . . . .53400553 . . . . . . . . . . . . . . . . . .53400557 . . . . . . . . . . . . . . . . . .54400570 . . . . . . . . . . . . . . . . . .54400571 . . . . . . . . . . . . . . . . . .54400572 . . . . . . . . . . . . . . . . . .54400574 . . . . . . . . . . . . . . . . . .54400575 . . . . . . . . . . . . . . . . . .54400576 . . . . . . . . . . . . . . . . . .54400577 . . . . . . . . . . . . . . . . . .54400579 . . . . . . . . . . . . . . . . . .54405119 . . . . . . . . . . . . . . . . . .51405120 . . . . . . . . . . . . . . . . . .51405121 . . . . . . . . . . . . . . . . . .51405122 . . . . . . . . . . . . . . . . . .53405123 . . . . . . . . . . . . . . . . . .53405124 . . . . . . . . . . . . . . . . . .53410002 . . . . . . . . . . . . . . . . . .18500201 . . . . . . . . . . . . . . . . . .45
500202 . . . . . . . . . . . . . . . . . .45500203 . . . . . . . . . . . . . . . . . .45500204 . . . . . . . . . . . . . . . . . .45500205 . . . . . . . . . . . . . . . . . .45500206 . . . . . . . . . . . . . . . . . .45500207 . . . . . . . . . . . . . . . . . .45520004P . . . . . . . . . . . . . . . .77520007P . . . . . . . . . . . . . . . .77560001A . . . .27, 29, 30, 32, 43, . . . . . . . . . .44, 48, 49, 50, 52, 54560002A . . . .27, 35, 39, 46, 47, . . . . . . . . . . . . . . . . . . . . . .51, 53560002BA . . . . . .35, 39, 46, 47, . . . . . . . . . . . . . . . . . . . . . .51, 53560002RA . . . . . .35, 39, 46, 47, . . . . . . . . . . . . . . . . . . . . . .51, 53560002YA . . . . . .35, 39, 46, 47, . . . . . . . . . . . . . . . . . . . . . .51, 53560003A . . . .27, 35, 39, 46, 47, . . . . . . . . . . . . . . . . . . . . . .51, 53560004A . . . .27, 29, 30, 32, 43, . . . . . . . . . .44, 48, 49, 50, 52, 546DYNTP001 . . . . . . . . . . . . . .306FMC00789 . . . . . . . . . . . . . .44DS1002200 . . . . . . . . . . . . . .64DS1002250 . . . . . . . . . . . . . .64DS1205000 . . . . . . . . . . . . . .64DS1205050 . . . . . . . . . . . . . .64DS8501700 . . . . . . . . . . . . . .64DS8501750 . . . . . . . . . . . . . .64DS8502200 . . . . . . . . . . . . . .64DS8502250 . . . . . . . . . . . . . .64DS8505000 . . . . . . . . . . . . . .64DS8505050 . . . . . . . . . . . . . .64EZC030060 . . . . . . . . . . . . . .66EZC055060 . . . . . . . . . . . . . .66EZC120L060 . . . . . . . . . . . . .66EZC120S060 . . . . . . . . . . . . .66EZC150060 . . . . . . . . . . . . . .66MP307017 . . . . . . . . . . . . . . .90SU10 . . . . . . . . . . . . . . . . . . .68SU105 . . . . . . . . . . . . . . . . . .68SU11 . . . . . . . . . . . . . . . . . . .68SU6 . . . . . . . . . . . . . . . . . . . .68SU7 . . . . . . . . . . . . . . . . . . . .68SU8 . . . . . . . . . . . . . . . . . . . .68SU9 . . . . . . . . . . . . . . . . . . . .68SU95 . . . . . . . . . . . . . . . . . . .68SUL7 . . . . . . . . . . . . . . . . . . .68SUL8 . . . . . . . . . . . . . . . . . . .68SUL9 . . . . . . . . . . . . . . . . . . .68XD10775003 . . . . . . . . . .18, 70XD10775004 . . . . . . . . . .18, 70
Catalog Number Page Catalog Number Page Catalog Number Page
34ELECTROPHYSIOLOGY
3Bard Electrophysiology DivisionC. R. Bard, Inc.55 Technology DriveLowell, MA 01851 USATel: (978) 441-6202Fax: (978) 323-2222www.bardep.comwww.crbard.com
AUSTRALIABard Australia, Pty LtdTel 61-2-8875-4000Fax 61-2-8875-4050
AUSTRIABard Medica S.A.Tel 43-1-4949-130Fax 43-1-4949-13030
BELGIUMBard Benelux, N.V.Tel 32-14-286950Fax 32-14-286955
CANADABard Canada, Inc.Tel 289-291-8000Fax 800-632-2109
CHINABard International, Inc.Tel 86-10-6506-5252Fax 86-10-6551-2228
ENGLANDBard LimitedTel 44-1-293-527-888Fax 44-1-293-552-428
FRANCEBard France S.A.S.Tel 33-1-39-30-5858Fax 33-1-39-30-5859
GERMANYBard GmbH/Angiomed GTCTel 49-721-9445-0Fax 49-721-9445-111
GREECEBard Hellas SATel 30-210-969-0707Fax 30-210-962-8810
INDIABard South AsiaTel 91-22-2612-3783Fax 91-22-2612-3821
ITALYBard S.p.A.Tel 39-06-52-4931Fax 39-06-52-95852
PORTUGALC. R. Bard Portugal, LDATel 351-21-319-0330Fax 351-21-319-0339
SINGAPOREBard Singapore Pte. Ltd.Tel 65-6250-7311Fax 65-6353-7311
SPAINBard De Espana, SATel 34-93-253-7800Fax 34-93-253-7834
SWEDENBard Norden ABTel 46-42-386-000Fax 46-42-386-010
SWITZERLANDBard Medica, SATel 41-17-225-360Fax 41-17-225-370
TAIWANBard Pacific Healthcare Co.Tel 886-2274-07-893Fax 886-2277-75-576
USABard Electrophysiology DivisionTel 978-441-6202 Main800-824-8724 Customer ServiceFax 978-323-2222 Main877-281-1492 Customer Service
USA/ASIA PACIFICBard Asia Pacific DivisionTel 908-277-8000Fax 908-277-8090
USA/JAPANMedicon, Inc.Tel 908-277-8000Fax 908-277-8090
USA/LATIN AMERICABard Latin AmericaTel 908-277-8000Fax 908-277-8090
WEST MALAYSIABard Sdn BhdTel 6-04-480-1300Fax 6-04-489-1737
Before use, consult product labels and inserts for any indications, contraindications, hazards, warnings, cautions and instruction for use.Bard and the stylized heart design, Scorpion 2, Stinger, HD Mesh Mapper, Orbiter PV, EP•XT,Dynamic Tip, Dynamic XT, Radia, WovenFlexie, Viking, Viking Soft Tip, Tango, Oribter, Orbiter ST,Channel, TSX, NBIH, Goetz, Zucker, Myler, Gorlin, LabSystem, EPLogix, Clearsign, EPLink, SureLink,Tempulse, Templink, Easy-Mate, Josephson, Sterrad, Curvelock, EZCross, SafeSheath, DiRex andEasyCool are trademarks and/or registered trademarks of C. R. Bard, Inc. Cournand is a registered trademark licensed to C. R. Bard, Inc. All other trademarks are the property of theirrespective owners. © 2013 C. R. Bard, Inc. All rights reserved. LT04Z0024/Rev. 7/01-2013
Products are not available in all geographies. Check with your local Bard Representative for product availability.