interlocking esd floor tiles - bondline · 2020. 10. 5. · en 13329-549 549kg/cm² en 140-8...
TRANSCRIPT
Technical Datasheet www.bondline.co.uk | Tel +44 (0) 1793 511000 | [email protected]
Interlocking ESD Floor Tiles
DescriptionThese electrostatic dissipative, interlocking ESD floortiles are ideal for both commercial and industrial use;including, production plants, electronics andtelecommunication factories, offices, data centres,healthcare environments, clean rooms and computerserver rooms. The tiles are a tough, flexible andmodern flooring solution. They create a safeconductive floor surface that can be used as yourprimary ground and offer a life-time guarantee thatwill help it retain its ESD performance.
FeaturesVery quick and easy to install - no adhesiverequired.Exceptional durability - Resistant to impact,vibration and abrasion.Excellent anti-slip properties.Environmentally friendly - 100% recyclable andzero VOC emissions.Manufactured using an injection-mouldingprocess during which thousands of tiny stainlesssteel fibres are added to the compound.Good chemical resistance - Resists mostchemicals and fluids.Reduces fatigue.Manufactured in the UK with ISO 9001Accreditation.BS EN 61340-5-1 and IEC 61340 compliant.
All our ESD Floor installations can be quoted as apackage tailor made to your ESD needs.
- Offices- Cleanrooms- Server Rooms
- Electronic Factories- Healthcare Environments- Data Centers
Light Grey & Dark GreyESD Logo Tile
Excellent to use in:
www.bondline.co.uk | Tel +44 (0) 1793 511000 | [email protected]
InstallationThe principal benefit of this system is the speed and ease of installation. The tiles can be laid over any hardsurface even if it is damp, uneven or contaminated. Installation can usually be fitted around your normalworking activities ensuring minimal disruption to production.
Surface Resistivity: 2.2 x 10⁴Ω to 3 x 10⁶ΩResistance to ground: 2.9 x 10⁴Ω to 5.7 x 10⁵ΩWalking Test: <100VStatic Decay at 15% humidity: 0.01sec
'Interlocking ESD Floor Tile' has been independentlytested.
The test results guarantee that the interlocking ESDfloor tiles complies with British Standard BS EN61340-5:2001 and IEC 61340.
Maintaining & Finishing
Recommended Cleaning Method
Technical Datasheet www.bondline.co.uk | Tel +44 (0) 1793 511000 | [email protected]
1) Leave a minimum of a 5mm gap between the tilesand any fixed point (walls and machinery).
2) Undercut wood doorjambs and slip the tilesunderneath.
3) With metal doorjambs – cut the flooring materialto within 5mm & then caulk around the jamb.
4) To keep your floor looking good give it a sweep ona regular basis and use a rotary scrubber dryer forroutine maintenance.
Failure to maintain interlocking ESD floor tiles inaccordance with recommended procedure can affectthe performance of the product. We recommendcleaning the tiles with our Killstat ESD Floor Cleaner.
1) Clean the tiles regularly and lightly.
2) Use the correct cleaning equipment, either a twocomponent bucket and mop system or rotaryscrubber dryer.
3) Do not use excessive amounts of water, this willmake your job more difficult; damp mopping is thebest solution.
4) To remove as much dirt and moisture as possible,use an entrance mat.
5) Heavily trafficked or highly visible areas need to becleaned more often than areas which are seldomused, or where appearance is less important.
6) Using excellent quality cleaning chemicals andequipment will ensure efficient maintenance.
Interlocking ESD Floor Tiles
www.bondline.co.uk | Tel +44 (0) 1793 511000 | [email protected]
Thickness 4.5mm +/- 0.3mm
DimensionsSpecifications
Anticipated Service Life
Material
500mm x 500mm
PVC
25 Years +Guarantee 10 Years
Joint Dovetail
Weight 5.44 kgs/m².
5mm 10mm500mm x 500mm6.8mm +/- 0.3mm8.86 kgs/m²10 Years25 Years +
PVC
Dovetail
Performance & Test Results
Important Notice: The information contained within this spec sheet is for guidance only. We make no warranties expressed orimplied and assume no liability regarding any use of this information. Interlocking ESD Floor Tiles, October 5th 2020.
www.bondline.co.uk | Tel +44 (0) 1793 511000 | [email protected]
Technical Datasheet www.bondline.co.uk | Tel +44 (0) 1793 511000 | [email protected]
SmoothSlip Resistance
Fire Performance
Stain Resistance
Abrasion Wear Resistance
EN 14041:2004 DIN 51130:2004
PassR10
GoodEN 423
EN 13845 EN 649
Mechanical Resistance
Resistance to Hot Objects/Solder
Thickness of Wear Layer
DIN 53516
EN 429
17N/mm²
Good
6 to 10mm
BS 476: Part 7 DIN 13501: 2004
Class 1 Spread of Flame Bfl-S1Does not support combustion
50K CyclesGroup T
Noise Reduction
Hardness ISO 868 89-92 Shore A
Impact Resistance
Thermal Insulation
EN 13329-549 549kg/cm²
EN 140-8 >46db
1.1 m²K/W
Determination of Length,Squareness & Straightness
EN 50105-BO21 5Colour Fastness
Chemical Resistance
BS EN 428:1993 <0.13% / 0.5mm max.
Good resistance to mostcommonly used chemicals.
Common acid oils & gas oil - Nodeterioration / Not Resistant to
prolonged contact
EN 13529
N/A
N/A
The maximum test voltage allowed for measuring ESD flooring that should beused for an ESD program complying with these standards is 100 volts.