intel® raid controller rs25db080 · what you will need to begin • sas 2.0 or sata iii hard disk...

1
What you will need to begin SAS 2.0 or SATA III hard disk drives (backward compatible to support SAS 1.0 or SATA II hard disk drives) Intel ® RAID Controller RS25DB080 Server board with a x8 or x16 PCI Express* slot (this controller is designed to meet the x8 PCI Express* Generation 2 specification and is backward compatible with generation 1 slots) Intel ® RAID Controller RS25DB080 Resource CD Operating system installation media: Microsoft Windows Server 2003*, Microsoft Windows Server 2008*, Microsoft Windows 7*, Microsoft Windows Vista*, Red Hat* Enterprise Linux, or SUSE* Linux Enterprise Server, VMware* ESX Server 4, and Citrix* Xen. Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2011, Intel Corporation. All rights reserved. Warning Read all caution and safety statements in this document before performing any of the instructions. Also see the Intel ® Server Board and Server Chassis Safety Information document at: http://support.intel.com/support/ motherboards/server/sb/cs-010770 .htm for complete safety information. Warning Installation and service of this product should only be performed by qualified service personnel to avoid risk of injury from electrical shock or energy hazard. Caution Observe normal ESD [Electrostatic Discharge] procedures during system integration to avoid possible damage to server board and/or other components. Tools Required Anti-static wrist strap Phillips* screwdriver Audible Alarm Information For information about the audible alarm and how to silence or disable it, see the reverse side of this document. Building Value with Intel Server Products, Programs and Support Get the high-value server solutions you need by taking advantage of the outstanding value Intel provides to system integrators: For more information on Intel's added-value server offerings, visit the Intel ® ServerBuilder website at: www.intel.com/go/serverbuilder. Worldwide 24x7 technical support (AT&T Country Code + 866-655-6565) 1 World-class service, including a three-year limited warranty and Advanced Warranty Replacement 1 High-quality server building blocks Extensive breadth of server building blocks Solutions and tools to enable e-Business Product information, including product briefs and technical product specifications Sales tools, such as videos and presentations Training information, such as the Intel ® Online Learning Center Support Information and much more Intel ® ServerBuilder is your one-stop shop for information about all of Intel's Server Building Blocks such as: 1 Available only to Intel ® Channel Program Members, part of Intel ® e-Business Network. Choosing the Right RAID Level 0 D4 D2 D4 D6 D8 D is k 2 D4 D1 D3 D5 D7 D is k 1 1 D4 D1 D2 D3 D4 D is k 2 D4 D1 D2 D3 D4 D is k 1 5 D4 D2 P D5 D8 D is k 2 D4 P D4 D6 P D is k 3 D4 D1 D3 P D7 D is k 1 6 D4 D2 P1 P2 D7 D is k 2 D4 P1 P2 D5 D8 D is k 3 D4 P2 D4 D6 P1 D is k 4 D4 D1 D3 P1 P2 D is k 1 60 D4 D1 P1 P2 D14 D is k 2 D4 D2 D5 P1 P2 D is k 3 D4 P2 D6 D10 P1 D is k 4 D4 P1 P2 D9 D13 D is k 1 D4 D3 P1 P2 D16 D is k 6 D4 D4 D7 P1 P2 D is k 7 D4 P2 D8 D12 P1 D is k 8 D4 P1 P2 D11 D15 D is k 5 10 D4 D1 D3 D5 D7 D is k 2 D4 D2 D4 D6 D8 D is k 3 D4 D2 D4 D6 D8 D is k 4 D4 D1 D3 D5 D7 D is k 1 R1 R1 R0 50 R0 R6 R6 2 NONE Striping (speed) 100% Excellent Excellent High throughput workstation 2 1 Mirroring (redundancy) 50% Very good Good OS, apps entry level 3 1 Striping and distributed parity (fault tolerance) n-1 (67-94%) Very good Good Data, web/media server 3 2 Striping with dual distributed parity n-2 (50-88%) Good Good High fault tolerance 4 1 per mirror set Striping across mirrors 50% Very good Good 6 2 per R6 set Striping across R6 arrays n-4 (50-88%) Very good Good Critical data 6 1 per R5 set Striping across R5 arrays n-2 (67-94%) Excellent Very Good Database, file, mail servers Minimum Physical Drives RAID Fail PDs Allowed Method Capacity Read Speed Write Speed Good Usage D4 D2 P D5 D14 D4 P D6 D10 P D4 D1 D5 P D13 D4 D4 P D11 D16 D4 P D8 D12 P D4 D3 D7 P D15 D is k 1 D is k 2 D is k 3 D is k 4 D is k 5 D is k 6 Database, file, mail servers R5 R0 R5 For more information on the jumpers referenced in this diagram, refer to user guide located on the web at: http://support.intel.com/support/motherboards/server. G22852-001 This guide contains step-by-step instructions for installing the Intel® RAID Controller RS25DB080 and information on using the BIOS setup utility to configure a single logical drive array and install the driver into the operating system. These guides and other supporting documents (including a list of supported server boards) are also located on the web at: http://support.intel.com/support/motherboards/server. For more advanced RAID configurations, or to install with other operating systems, please refer to the Hardware User’s Guide. Read all cautions and warnings first before starting your RAID Controller integration. If you are not familiar with ESD (Electrostatic Discharge) procedures used during system integration, see your Hardware Guide for complete ESD procedures. For more details on Intel ® RAID controllers, see: www.intel.com/go/serverbuilder. Intel® RAID Controller RS25DB080 Quick Start User's Guide 1 Check the Bracket Height Determine whether the full-height bracket will fit in the server’s PCI back plate. A Your RAID controller ships with the full-height bracket. If the low-profile bracket is required, unscrew the two fasteners holding the green board to the silver bracket. B Line up the low-profile bracket with the board, making sure the two holes align. D Replace and tighten the two screws. E Remove the bracket. C Full-height Bracket Low-profile Bracket 2 Install the RAID Controller Power down the system and disconnect the power cord. A Remove the system cover and any other pieces to access the PCI Express* slot. B Firmly press the RAID Controller into an available x8 or x16 PCI Express* Slot. C Secure the RAID Controller bracket to the system back panel. D PCI Express* Slot (3.3 V) 3 Connect the RAID Controller Connect the wide end of the provided cable to the left silver connector (ports 0-3). A Push the cable into the silver connector until it makes a slight click. B If using more than four drives, connect the wide end of the second provided cable to the right silver connector (ports 4-7). C Connect the other ends of the cables to SATA drives or to the ports on a SATA or SAS backplane. Notes: Both non-expander backplanes (one cable per drive) and expander backplanes (one or two total cables) are supported. Drive power cables (not shown) are required. D Go to Step 4 on Side 2 Rear view of four SATA drives connected to ports 0-3 on the Intel ® RAID Controller RS25DB080. D Ports 4-7 Ports 0-3 C A B Intel® RAID Controller RS25DB080 Reference Diagram Front View Back View Memory Board Connector The Memory Board is installed on RAID controller baseboard by default Remote battery backup module or SuperCap module connector J2B1 Ports 0-3 J5B1 Memory Board Connector J5A1 J6A1 J2B2 Ports 4-7 Bracket Screw (2) Speaker J2B3 J2B4 x8 PCI Express* Interface Memory Board Mounting Holes (4) J1A7 J1A5 J1A4 J1A2 J1A1 J1A3

Upload: others

Post on 30-Oct-2019

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Intel® RAID Controller RS25DB080 · What you will need to begin • SAS 2.0 or SATA III hard disk drives (backward compatible to support SAS 1.0 or SATA II hard disk drives) •

What you will need to begin• SAS 2.0 or SATA III hard disk drives (backward compatible to support SAS 1.0 or SATA II hard disk drives) • Intel® RAID Controller RS25DB080• Server board with a x8 or x16 PCI Express* slot (this controller is designed to meet the x8 PCI Express* Generation 2 specification and is backward compatible with generation 1 slots)• Intel® RAID Controller RS25DB080 Resource CD• Operating system installation media: Microsoft Windows Server 2003*, Microsoft Windows Server 2008*, Microsoft Windows 7*, Microsoft Windows Vista*, Red Hat* Enterprise Linux, or SUSE* Linux Enterprise Server, VMware* ESX Server 4, and Citrix* Xen.

Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2011, Intel Corporation. All rights reserved.

Warning

Read all caution and safety statements in this document before performing any of the instructions. Also see the Intel® Server Board and Server Chassis Safety Information document at:http://support.intel.com/support/motherboards/server/sb/cs-010770.htm for complete safety information.

Warning

Installation and service of this product should only be performed by qualified service personnel to avoid risk of injury from electrical shock or energy hazard.

Caution

Observe normal ESD [Electrostatic Discharge] procedures during system integration to avoid possible damage to server board and/or other components.

Tools Required

Anti-staticwrist strap

Phillips*screwdriver

Audible Alarm InformationFor information about the audible alarm and how to silence or disable it, see the reverse side of this document.

Building Value with IntelServer Products, Programs and Support

Get the high-value server solutions you need by taking advantage of the outstanding value Intel provides to system integrators:

For more information on Intel's added-valueserver offerings, visit the Intel® ServerBuilderwebsite at: www.intel.com/go/serverbuilder.

• Worldwide 24x7 technical support (AT&T Country Code + 866-655-6565)1

• World-class service, including a three-year limited warranty and Advanced Warranty Replacement1

• High-quality server building blocks• Extensive breadth of server building blocks• Solutions and tools to enable e-Business

• Product information, including product briefs and technical product specifications• Sales tools, such as videos and presentations• Training information, such as the Intel® Online Learning Center• Support Information and much more

Intel® ServerBuilder is your one-stop shop for information about all of Intel's Server Building Blocks such as:

1Available only to Intel® Channel Program Members, part of Intel® e-Business Network.

Choosing the Right RAID Level

0 D4D2D4D6D8Disk 2

D4D1D3D5D7Disk 1

1 D4D1D2D3D4Disk 2

D4D1D2D3D4Disk 1

5 D4D2P

D5D8Disk 2

D4P

D4D6PDisk 3

D4D1D3P

D7Disk 1

6 D4D2P1P2D7Disk 2

D4P1P2D5D8Disk 3

D4P2D4D6P1Disk 4

D4D1D3P1P2Disk 1

60

D4D1P1P2

D14Disk 2

D4D2D5P1P2Disk 3

D4P2D6

D10P1Disk 4

D4P1P2D9

D13Disk 1

D4D3P1P2

D16Disk 6

D4D4D7P1P2Disk 7

D4P2D8

D12P1Disk 8

D4P1P2

D11D15Disk 5

10 D4D1D3D5D7Disk 2

D4D2D4D6D8Disk 3

D4D2D4D6D8Disk 4

D4D1D3D5D7Disk 1

R1 R1

R0

50

R0

R6

R6

2 NONE Striping (speed) 100% Excellent Excellent High throughputworkstation

2 1 Mirroring (redundancy)

50% Verygood

Good OS, appsentry level

3 1 Striping and distributedparity (fault tolerance)

n-1(67-94%)

Verygood

Good Data, web/mediaserver

3 2 Striping with dualdistributed parity

n-2(50-88%)

Good Good High faulttolerance

4 1 permirror set

Striping across mirrors

50% Verygood

Good

6 2 per R6set

Striping across R6arrays

n-4(50-88%)

Verygood

Good Critical data

6 1 per R5set

Striping across R5arrays

n-2(67-94%)

Excellent VeryGood

Database, file,mail servers

MinimumPhysicalDrivesRAID

Fail PDsAllowed Method Capacity

ReadSpeed

WriteSpeed Good Usage

D4D2P

D5D14

D4P

D6D10

P

D4D1D5P

D13

D4D4P

D11D16

D4P

D8D12

P

D4D3D7P

D15Disk 1 Disk 2 Disk 3 Disk 4 Disk 5 Disk 6

Database, file,mail servers

R5

R0

R5

For more information on the jumpers referenced in this diagram, refer to user guide located on the web at: http://support.intel.com/support/motherboards/server.

G22852-001

This guide contains step-by-step instructions for installing the Intel® RAID Controller RS25DB080 and information onusing the BIOS setup utility to configure a single logicaldrive array and install the driver into the operating system.

These guides and other supporting documents (including a list of supported server boards) are also located on the web at: http://support.intel.com/support/motherboards/server.

For more advanced RAID configurations, or to install with otheroperating systems, please refer to the Hardware User’s Guide.

Read all cautions and warnings first before starting your RAID Controller integration.

If you are not familiar with ESD (Electrostatic Discharge) procedures used during system integration, see your Hardware Guide for complete ESD procedures. For more details on Intel® RAID controllers, see: www.intel.com/go/serverbuilder.

Intel® RAID Controller RS25DB080Quick Start User's Guide

1 Check the Bracket Height

Determine whether the full-height bracket will fit in the server’s PCI back plate.

A

Your RAID controller ships with the full-height bracket. If the low-profile bracket is required, unscrew the two fasteners holding the green board to the silver bracket.

B

Line up the low-profile bracket with the board,making sure the two holes align.

D

Replace and tighten the two screws.

E

Remove the bracket.C

Full-heightBracket

Low-profileBracket

2 Install the RAID ControllerPower down the system and disconnect the power cord.

A

Remove the system cover and anyother pieces to access thePCI Express* slot.

B

Firmly press the RAID Controller into an available x8 or x16 PCI Express* Slot.

C

Secure the RAID Controller bracket to the system back panel.

D

PCI Express* Slot (3.3 V)

3 Connect the RAID ControllerConnect the wide end of the provided cable to the left silverconnector (ports 0-3).

A

Push the cable into the silver connector until it makes a slight click.BIf using more than four drives, connect the wide end of the secondprovided cable to the right silver connector (ports 4-7).

C

Connect the other ends of the cables to SATA drives or to the portson a SATA or SAS backplane.

Notes: Both non-expander backplanes (one cable per drive) and expander backplanes (one or two total cables) are supported. Drive power cables (not shown) are required.

D

Go to Step 4 on Side 2

Rear view of four SATA drives connected to ports 0-3on the Intel® RAID Controller RS25DB080.

D

Ports 4-7

Ports 0-3

CA

B

Intel® RAID Controller RS25DB080 Reference Diagram

Front View Back View

Memory BoardConnector

The Memory Board is installed on RAID

controller baseboard by default

Remote battery backup module or

SuperCap module connector

J2B1 Ports 0-3

J5B1Memory BoardConnector

J5A1

J6A1

J2B2 Ports 4-7

BracketScrew (2)

Speaker

J2B3

J2B4x8 PCI

Express*Interface

Memory BoardMountingHoles (4)

J1A7

J1A5

J1A4

J1A2

J1A1

J1A3