integrated smoke control solutions

10
INTEGRATED SMOKE CONTROL SOLUTIONS FOR CAR PARKS, STAIRCASES, FIRE-FIGHTING LOBBIES AND ESCAPE ROUTES EN-12101-3 Powered smoke and heat exhaust ventilators for use in Construction Works

Upload: others

Post on 03-Jul-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTEGRATED SMOKE CONTROL SOLUTIONS

INTEGRATED SMOKE CONTROL SOLUTIONS

FOR CAR PARKS, STAIRCASES, FIRE-FIGHTING LOBBIES AND ESCAPE ROUTES

EN-12101-3Powered smoke and heat exhaust ventilators for use in Construction Works

Page 2: INTEGRATED SMOKE CONTROL SOLUTIONS

SODECA has focused its business activity on the manufacture of industrial fans, ventilation systems and smoke extract fans for fire protection since it was formed in 1983.

With the help of comprehensive research and development methods SODECA fans are installed extensively around Europe and many other parts of the world. SODECA has a commanding position as one of the best and most widely recognised fan manufacturers in Europe thanks to stringent quality control procedures to ISO 9001:2015.

The “human factor” is extremely important in achieving our objectives and we are proud to have highly professional people working at SODECA. People who can offer ventilation solutions as well as equipment for our customer’s needs. Our customers can visit our 16,000m² production facility near Sant Quirze de Besora, where we manufacture ventilation equipment of the highest quality to ISO and AMCA standards.

This catalogue contains just a few of the options we can offer. Please contact us and our experienced staff will be at your disposal.

Page 3: INTEGRATED SMOKE CONTROL SOLUTIONS

EXPERTS IN SMOKE CONTROL

SODECA has wide experience in the design and fabrication of equipment for ventilation and smoke exhaust in car parks.

Our projects department distinguishes itself from other companies by offering project design services and best-practise advice. It has specialist technicians who can deliver a comprehensive technical study, including sizing of equipment and required plant space.

In addition, SODECA offers the option of testing installations using real (hot) smoke tests.

They are experienced users of advanced Computational Fluid Dynamics (CFD) software, which they use to validate design parameters and simulate values such as smoke behaviour, temperature, visibility, air velocities and CO concentration.

SODECA adapts to the needs of each client, offering comprehensive ventilation and smoke control solutions:

CAR PARK VENTILATION.

VENTILATION FOR STAIRCASES AND ESCAPE ROUTES.

SMOKE EXTRACT CONTROL SYSTEMS.

COMPREHENSIVE SOLUTIONS—

Page 4: INTEGRATED SMOKE CONTROL SOLUTIONS

In modern buildings, car parks are now anoth-er feature of the building architecture. In many cases, they are the first space visitors enter in buildings such as shopping centres, entertain-ment complexes, offices and passenger trans-port hubs.

Correct car park ventilation plays an important role in the first impressions of a visitor. For this reason, they must be designed to satisfy the highest environmental quality standards. In other words, the lowest possible concentra-tions of contaminant gases must be achieved, whilst at the same time, eliminating foul odours.

But these are not the only factors. A high de-gree of safety must be guaranteed in the event of fire and car park ventilation is essential for providing adequate conditions for evacu-ation of occupants and to aid fire-fighting operations.

CAR PARK VENTILATION—

VISIBILITY

Improved visibility in the fire zone

AIR

Supply of fresh air to reduce smoke toxicity

TEMPERATURE

Reduction of air temperature in the fire zone

Page 5: INTEGRATED SMOKE CONTROL SOLUTIONS

JET FAN SMOKE CONTROL SYSTEM

Jet fan smoke control systems are considered the most suitable ventilation solution for large, unobstructed spaces such as car parks and tunnels.

Installing this type of fan reduces the need to install air sup-ply and extract ducts, improving visibility in car parks and in-creasing available clearance height. In the event of fire, the jet fans generate an air current that pushes smoke toward extract points.

Applications

Ventilation for contaminant gas control.Ventilation in the event

of fire.

Ventilation for contaminant gas control.Ventilation in the event

of fire.

Ventilation for contaminant gas control.Ventilation in the event

of fire.

Ventilation for contaminant gas control.Ventilation in the event

of fire.

Installation

Indoor. Below ceiling Indoor. Below ceiling Indoor, in ventilation shafts or plant room. On the roof

Safety switch

Included in L and O versions.

C version on request.Included On request Included

2-speed fan

Yes Yes 1 or 2-speed versions 1 or 2-speed versions

Temperature classification based on EN 12101-3

F300 / F400120 F300 / F400120 F300 / F400120 F300 / F400120

Version without temperature classification

HCT/IMP CI-CO HCT/HGT -

Reversible fan version

Yes No Yes Yes

THT/IMP CI THT THT/HATCH

Page 6: INTEGRATED SMOKE CONTROL SOLUTIONS

VISIBILITY

Visibility is ensured

EVACUATION

Safe evacuation of occupants

SAFETY

Easy access for firefighters

Pressurisation control systems prevent smoke from entering escape routes by pressurising those spaces. When the system is running, if doors are opened or in the event of air leakage, the system reacts by increasing the airflow rate. This guarantees that escape routes are always free of smoke in an emergency situation.

Escape routes include corridors, staircases, lifts and lobbies.

When selecting and classifying a system for a specific project, it is necessary to con-sider the building use, size and evacua-tion instructions in the event of fire. These criteria will help determine the necessary flow rate delivered by the pressurisation equipment.

The choice of system is very important as, this will also determine flow rates depend-ing on the class.

VENTILATION FOR STAIRCASES AND ESCAPE ROUTES—

Page 7: INTEGRATED SMOKE CONTROL SOLUTIONS

PRESSURISATION SYSTEMS FOR ESCAPE ROUTES IN THE EVENT OF A FIRESODECA has the following solutions for smoke extract in staircases, fire-fighting lobbies and escape routes:

Applications

Staircases, corridors, lifts, lobbies

Staircases, corridors, lifts, lobbies

Staircases, corridors, lifts, lobbies Lobbies

Installation

On the roof, indoor

On the roof, indoor On the roof Only lobbies

Inlet hatches management

- Yes Yes -

Inlet leak detection

- Yes Yes -

Smoke detection

- Yes Yes -

Compatible with fire cabinets

Yes Yes Yes -

Self-calibration

- Yes Yes -

Connection to BMS systems

Yes Yes Yes Yes

KIT SOBREPRESIÓN KIT BOXPDS HATCH PDS PRESSKIT

Page 8: INTEGRATED SMOKE CONTROL SOLUTIONS

For air supply and smoke extract systems in fires, with or without jet fans, SODECA has the BOXPARK control panels, which facilitate the integration of the ventilation system with CO and fire detection alarms.

The BOXPARK control panels are adapted to common ventilation system needs in fires, and can also be customised for large projects with the possibility of adding modules to the system.

We also supply fire-fighting and maintenance control panels.

SMOKE EXTRACT CONTROL SYSTEMS—

Direct communication with CO and FIRE stations

Fan control: air extract, supply and jet fans

Hatch control: air extract and supply

CONTROL SYSTEMBOXPARK CONTROL MASTER

Page 9: INTEGRATED SMOKE CONTROL SOLUTIONS

SMOKE EXTRACT AND COCONTROL SYSTEMSFor automated operation of ventilation systems, depending on the specific needs of the car park.

This equipment controls the ventilation system operation, depending on the CO concentration or through the activation from a fire detection station. It also allows day-to-day programming of the car park ventila-tion system.

Applications

Automated or manual ventilation control CO concentration control

Installation

In plant room In plant room

Automated operating modes

By fire detection.By CO detection.

Standard automation.Advanced automation with power savings.

Manual operation Programmable activation levels

Speed selection (high/low).Fan selection.

Three levels with digital outputs.Analogue output for variable frequency drive.

Time programming Programmable activation levels

Ventilation system (high/low).Operating periods.

1, 2 or 3 zones with up to 32 sensors per zone.Independent zone management.

Connection to

MODBUS, RTU and CAN open systems MODBUS

Ventilation control

By contactors.Variable frequency control.

1, 2 or 3 progressive stages.Proportional control.

BOXPARK CENTRAL CO

Page 10: INTEGRATED SMOKE CONTROL SOLUTIONS

www.sodeca.com

HEADQUARTERSodeca S.L.U.Ctra. de Berga, km 0,7E-08580 SANT QUIRZE DE BESORABarcelona, SPAINTel. +34 93 852 91 11Fax +34 93 852 90 42General sales: [email protected] sales: [email protected]

CHILESodeca Ventiladores, Ltda.Sr. Frederic CousquerSanta Bernardita 12.005(Esquina con Puerta Sur)Bodegas 24 a 26, San Bernado, Santiago, CHILETel. +56 22 840 [email protected]

COLOMBIASodeca Latam, S.A.S.Sra. Luisa Stella PrietoCalle7 No. 13 A-44Manzana 4 Lote1, MontanaMosquera, CundinamarcaBogotá, COLOMBIATel. +57 1 756 [email protected]

PERÚSodeca Perú, S.A.C.Sr. Jose Luis JiménezC/ Mariscal Jose Luis de Orbegoso 331. Urb. El pino. 15022 , San Luis. Lima, PERÚTel. +51 1 326 24 24Cel. +51 [email protected]

RUSSIASodeca, L.L.C.Mr. Stanislav AlifanovMyasischeva str, 1, room 603Business Сenter “Chaika”140180 ZhukovskiyMoscow region, RUSSIATel. +7 495 955 90 [email protected]

AMERICA

RUSSIA

FINLANDSodeca Finland, OyMr. Kai Yli-SipiläMetsälinnankatu 30, PL2FI-32700 Huittinen FINLANDTel. + 358 400 320 [email protected]

UNITED KINGDOMSodeca Fans UK, Ltd.Mr. Mark NewcombeTamworth Enterprise CentrePhilip Dix House, Corporation Street, Tamworth , B79 7DNUNITED KINGDOMTel. +44 (0) 1827 216 [email protected]

PORTORua Veloso Salgado 1120/1138 4450-801 Leça de PalmeiraTel. +351 229 991 [email protected]

LISBOAPq. Emp. da Granja Pav. 8 2625-607 Vialonga Tel. +351 219 748 [email protected]

ALGARVERua da Alegria S/N8200-557 CortesõesTel. +351 289 092 [email protected]

EUROPE

PORTUGALSodeca Portugal, Unip. Lda.

CARIBBEAN ZONESodeca CubaResidencial MiramarApto. Nº 108, Ave. 7ma Nº 1805 entre 18 y 20, Miramar Playa, La Habana, CUBATel. +537 20 [email protected]