integrated deluge skid - naffco fzco · place the skid at the desired location on the proper...

4
130 www.shieldglobal.com INSTALLATION 1. Place the skid at the desired location on the proper foundation and secure it with the anchoring bolts. 2. Connect the water inlet and system piping. 3. Connect the common drain connection to an open drain. 4. Do not restrict or reduce the drain piping. 5. Connect the detection network piping 6. Complete the field wiring of junction box. 7. Refer to appropriate deluge valve catalogue for valve commissioning, installation and throubleshooting instructions. DESCRIPTION Models SD-DPACK and SD-DSK are integrated deluge skid systems. SD-DSK is pre-assembled open skid mounted on frame, while SD-DPACK is cabinet mounted. The entire package is pre wired and all water connections have flanged ends to provide minimal installation time. The package includes inlet, outlet, bypass valves, pressure switches, solenoid valve, common drain and flanged connection for detection network. FEATURES 1. Professionally pre-assembled and factory tested 2. UL Listed modular package 3. Quick and convenient installation 4. Internally wired 5. Cost effective and reduced installation time 6. Compact, asthetically pleasing appearance Note: Support the external piping firmly to prevent strain and stresses on the piping of the skid/cabinet and its components. INTEGRATED DELUGE SKID MODEL: SD-DSK-AD, SD-DSK-AW SD-DPACK-AD, SD-DPACK-AW SD-DVCH2, SD-DVCH3 TECHNICAL DATA NORMAL SIZE 200,150,100, 80, 50 NB ACTUATION Electric, Dry Pilot or Wet Pilot and Manual Release TRIM Galvanized steel with brass valves as standard supply. Optional Stainless Steel FINISH RAL 3000 Painted ORDERING Size, Deluge valve model, INFORMATION Trim Type Mounting (Vertical or Horizontal) Model of Skid Deluge Valve Model Skid Type Pressure Rating PSI Actuation Type Dry Pilot Wet Pilot Electric Manual Release SD-DSK-AD SD-DVA Open Skid 175 - SD-DSK-AW SD-DVA Open Skid 175 - SD-DPACK-AD SD-DVA Cabinet 175 - SD-DPACK-AW SD-DVA Cabinet 175 - SD-DVCH2 SD-DVH2 Cabinet 250 SD-DVCH3 SD-DVH3 Cabinet 250

Upload: others

Post on 18-Sep-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTEGRATED DELUGE SKID - NAFFCO FZCO · Place the skid at the desired location on the proper foundation and secure it with the anchoring bolts. 2. Connect the water inlet and system

130 www.shieldglobal.com

INSTALLATION

1. Place the skid at the desired location on the proper foundation and secure it with the anchoring bolts.2. Connect the water inlet and system piping.3. Connect the common drain connection to an open drain.4. Do not restrict or reduce the drain piping.5. Connect the detection network piping6. Complete the field wiring of junction box. 7. Refer to appropriate deluge valve catalogue for valve commissioning, installation and throubleshooting instructions.

DESCRIPTIONModels SD-DPACK and SD-DSK are integrated deluge skid systems. SD-DSK is pre-assembled open skid mounted on frame, while SD-DPACK is cabinet mounted. The entire package is pre wired and all water connections have flanged ends to provide minimal installation time. The package includes inlet, outlet, bypass valves, pressure switches, solenoid valve, common drain and flanged connection for detection network.

FEATURES

1. Professionally pre-assembled and factory tested2. UL Listed modular package3. Quick and convenient installation4. Internally wired5. Cost effective and reduced installation time6. Compact, asthetically pleasing appearance

Note: Support the external piping firmly to prevent strainand stresses on the piping of the skid/cabinet and its components.

INTEGRATED DELUGE SKID

MODEL: SD-DSK-AD, SD-DSK-AW SD-DPACK-AD, SD-DPACK-AW SD-DVCH2, SD-DVCH3

TECHNICAL DATANORMAL SIZE 200,150,100, 80, 50 NB

ACTUATION Electric, Dry Pilot or Wet Pilot and Manual Release

TRIM Galvanized steel with brass valves as standard supply. Optional Stainless Steel

FINISH RAL 3000 Painted

ORDERING Size, Deluge valve model, INFORMATION Trim Type Mounting (Vertical or Horizontal)

Model of Skid

Deluge Valve Model

Skid TypePressure

Rating PSI

Actuation Type

Dry Pilot Wet Pilot ElectricManual Release

SD-DSK-AD SD-DVA Open Skid 175 -

SD-DSK-AW SD-DVA Open Skid 175 -

SD-DPACK-AD SD-DVA Cabinet 175 -

SD-DPACK-AW SD-DVA Cabinet 175 -

SD-DVCH2 SD-DVH2 Cabinet 250

SD-DVCH3 SD-DVH3 Cabinet 250

Page 2: INTEGRATED DELUGE SKID - NAFFCO FZCO · Place the skid at the desired location on the proper foundation and secure it with the anchoring bolts. 2. Connect the water inlet and system

131www.shieldglobal.com

DELUGE VALVE SKID MODEL SD-DSK-AD WITH DRY PILOT &ELECTRIC ACTUATION TRIM

DELUGE VALVE SKID MODEL SD-DSK-AW WITH WET PILOT &ELECTRIC ACTUATION TRIM

DETECTION LINE

SPRINKLER ALARM (GONG)

DETECTION LINE

WATER INLETWATER OUTLET

SPRINKLER ALARM (GONG)

DETECTION LINE

WATER INLETWATER OUTLET

Page 3: INTEGRATED DELUGE SKID - NAFFCO FZCO · Place the skid at the desired location on the proper foundation and secure it with the anchoring bolts. 2. Connect the water inlet and system

132 www.shieldglobal.com

DELUGE VALVE SKID MODEL SD-DPACK-AD WITH DRY PILOT &ELECTRIC ACTUATION TRIM

DELUGE VALVE SKID MODEL SD-DPACK-AW WITH WET PILOT &ELECTRIC ACTUATION TRIM

DETECTION LINE

WATER INLETWATER OUTLET

SPRINKLER ALARM (GONG)

DETECTION LINE

WATER INLETWATER OUTLET

SPRINKLER ALARM (GONG)

DETECTION LINE

Page 4: INTEGRATED DELUGE SKID - NAFFCO FZCO · Place the skid at the desired location on the proper foundation and secure it with the anchoring bolts. 2. Connect the water inlet and system

133www.shieldglobal.com

DELUGE VALVE SKID MODEL SD-DVCH2 & SD-DVCH3 WITH DRY PILOT &ELECTRIC ACTUATION TRIM

DELUGE VALVE SKID MODEL SD-DVCH2 & SD-DVCH3 WITH WET PILOT &ELECTRIC ACTUATION TRIM

SPRINKLER ALARM(GONG)

WATER INLET

DETECTION LINE

WATER OUTLET

SPRINKLER ALARM(GONG)

WATER INLET

DETECTION LINE

WATER OUTLET