INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the kitchen and bath. Switch must be placed at the entrance.

Upload: gladys-ryan

Post on 22-Dec-2015

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

INTD 59 intro to kitchen & bath design

bathroom electrical, lighting & Title 24

CODE: At least one wall-switch controlled light must be provided in the kitchen and bath. Switch must be placed at the entrance.

Page 2: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

California residential lighting—title 24bathrooms—zone 2

• must have:• high efficacy fixtures• OR vacancy sensors installed that

control the low efficacy fixturesdimmer option

• vacancy sensors• allows user to manually turn on the

light upon entering the room• when vacancy detected, turns lights

off

Page 3: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

electrical

when gathering project information on site, note location of the main electrical panel & its rated amperage capacity

CODE: Ground fault circuit interrupter (GFCI) outlet protection is required on all receptacles servicing countertop surfaces in the kitchen and bath

all power outlets in the bath can be controlled on one circuit interrupter—power can be easily reset using button on primary outlet

Page 4: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

well-designed lighting of the utmost importance in bathrooms

typical mistake—recessed downlight over sink•harsh light hitting top of head•long dark shadows appear under eyes, nose & chin

Page 5: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

typical mistake—one surface-mounted above mirror•illuminates top of face•bottom half falls into shadow•especially hard light by which to shave

Page 6: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

task lighting at sink

use two luminaires flanking mirror

Page 7: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

task lighting at sink

use two luminaires flanking mirror

Page 8: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

task lighting at sink

Page 9: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

task lighting at sink

Page 10: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

task lighting at sink

Page 11: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

task lighting at sink

Page 12: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

task lighting at sink

use two luminaires flanking mirror

Page 13: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

lighting for tubs and showers

need a good general light that is listed for wet locations

Page 14: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

lighting for tubs and showers

recessed luminaires•render the upper-third of shower or tub area a little dimmer•do a better job of reducing glare•allow the use of higher wattage bulbs

CODE: All light fixtures installed within tub and shower spaces should be rated and marked “suitable for damp/wet locations”.

Switches shall not be installed within wet locations in tub or shower spaces or within reach while standing in the tub or shower unless installed as part of the listed tub or shower assembly.

Page 15: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

CODE: Hanging fixtures [such as chandeliers over tubs] cannot be located within a zone of 3 feet horizontally and 8 feet vertically from the top of the bathtub rim or shower stall threshold.

Page 16: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the
Page 17: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

ambient lighting

indirect lighting adds a warm overall glow•wall sconces•cove lighting

can find both in fluorescent or led lamps to comply with title 24

if higher ceilings, pendant-hung units are also a consideration

Page 18: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

skylights

supplement/replace ambient lighting during day:•white opal acrylic•UV filters specified•if light-well is deep enough, low-maintenance fluorescent/led strip-lights can be used to keep skylight lit at night

Page 19: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

exhaust fans

not required if operable windowsnice to have to remove steam and odors

make sure to specify separate switching for light & fan—if allowed by code

Page 20: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

lighting analysis

Page 21: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

lighting analysis

Page 22: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

lighting analysis

Page 23: INTD 59 intro to kitchen & bath design bathroom electrical, lighting & Title 24 CODE: At least one wall-switch controlled light must be provided in the

lighting analysis