Insulthane a Division of Elastochem a
www.Elastochem-ca.com/insulthane
Sealant
Sealant
Sealant
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
CONDITIONEDSPACE
CONDITIONED SPACE
CONDITIONED SPACE
Rigid backing tosupport insulation
D1.1bDec. 5, 2011
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Conditioned Basement
Sealant
CONDITIONED SPACE
CONDITIONEDBASEMENT
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Note:Concrete must cure at least 28 days prior to spray foam application. Concrete must be free of oil/release agents prior to application of spray foam insulation. Surface may require priming.
Spray foam insulationoptional at grade
D1.2Dec. 5, 2011
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Non-Conditioned Basement
Sealant
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
NON-CONDITIONEDBASEMENT
CONDITIONED SPACE
D1.3Dec. 5, 2011
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Vented Crawl Space
VENTEDCRAWL SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
SealantRadiant
Floor
D1.4Dec. 5, 2011
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Sealed Crawl Space
SEALEDCRAWL SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
SealantRadiant
Floor
Spray foam insulationoptional at grade
D1.5Dec. 5, 2011
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Cantilevered FloorOption A
CONDITIONED SPACE
CONDITIONEDSPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
D1.6aDec. 5, 2011
Sealant
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Cantilevered FloorOption B
CONDITIONED SPACE
CONDITIONEDSPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
D1.6bDec. 5, 2011
Sealant
Provide rigid backingto support insulation
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Finished Basement
Sealant
CONDITIONED SPACE
CONDITIONEDBASEMENT
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Note:Concrete must cure at least 28 days prior to spray foam application. Concrete must be free of oil/release agents prior to application of spray foam insulation. Surface may require priming.
Spray foam insulationoptional at grade
D1.7Dec. 5, 2011
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Garage with ConditionedSpace Above and Adjoining
CONDITIONED SPACE
CONDITIONEDSPACE
NON-CONDITIONEDGARAGE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
D1.8Dec. 5, 2011
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Basement Exterior
D1.9Dec. 5, 2011
Sealant
CONDITIONED SPACE
CONDITIONEDBASEMENT
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Note:Concrete must cure at least 28 days prior to spray foam application. Concrete must be free of oil/release agents prior to application of spray foam insulation. Surface may require priming.
Spray foam insulationoptional at grade
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Garage with ConditionedSpace Adjoining
D1.10Dec. 5, 2011
Sealant
CONDITIONED SPACE
CONDITIONED SPACE
NON-CONDITIONEDGARAGE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Note:Concrete must cure at least 28 days prior to spray foam application. Concrete must be free of oil/release agents prior to application of spray foam insulation. Surface may require priming.
Spray foam insulationoptional at grade
Sealant
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Garage wall Connection
D1.11Dec. 5, 2011
Sealant
CONDITIONED SPACE
CONDITIONED SPACENON-CONDITIONEDGARAGE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Rigid backing tosupport insulation
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Window Unit
D1.12Dec. 5, 2011
CONDITIONED SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
Sealant
Low-expansionfoam insulation
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Typical Wood-FramedWall with Siding
D1.13Dec. 5, 2011
EXTERIORCONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Typical Wood-Framed Wall with Masonry Veneer
D1.14Dec. 5, 2011
EXTERIORCONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Unheated Atticwith Mechanical Chase
D1.15Dec. 5, 2011
SEMI-CONDITIONED SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Rigid backing tosupport insulation.
Seal all electrical and plumbingpenetrations through top andbottom plates.
Sealant
Duct work chase
Fire stoparound duct
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Cathedral Ceiling with Skylight
D1.16Dec. 5, 2011
NON-CONDITIONED SPACE
CONDITIONED SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
Wind baffle may be requiredto obtain full insulation depth
Rigid backing tosupport insulation
Sealant
Sealant
Sealant
Low-expansionfoam insulation
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Flat Roof with Deck
D1.17Dec. 5, 2011
CONDITIONED SPACE
ROOF DECK(EXTERIOR)
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Cantilevered Bay Window
D1.18Dec. 5, 2011
CONDITIONEDSPACE
CONDITIONED SPACE
A A
PLAN VIEW OF SECTION A-A
EXTERIOR
CONDITIONED SPACE
EXTERIORNote:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
SealantSealant
Sealant
Sealant
Rigid backing tosupport insulation
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Pole Framed-Structure
D1.19Dec. 5, 2011
A A
PLAN VIEW OF SECTION A-A
NON-CONDITIONED SPACE
CONDITIONED SPACE
CO
ND
ITIO
NED
SPA
CE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Sealant
Wind baffle may be requiredto obtain full insulation depth
Spray foam insulationoptional at grade
EXTERIOR
EXTE
RIO
R
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Sound-Attenuating Wall
D1.20Dec. 5, 2011
2”x4” framing at 24” O.C.
AcousticSealant
⁵⁄₈” gupsum board
Spray foam insulation atminimum depth of 3½”
Note:Wall cavity should be filled with spray foam insulation for maximum sound attenuation.
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Sealed Crawl Space with Termite Inspection Area
D1.21Dec. 5, 2011
Leave minimum 4” block exposedto allow inspection for termites
SEALEDCRAWL SPACE
CONDITIONED SPACE
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
SealantRadiant
Floor
Spray foam insulationoptional at grade
EXTERIOR
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Steel-Framed Constructionwith Heated Interior
D1.22Jan. 4, 2012
CONDITIONED SPACEEXTERIOR
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
Spray foam insulationoptional at grade
Appr
ox. 4
8”
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Finished Room AboveNon-Conditioned Garage
Sealant
SealantNote:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
CONDITIONED SPACE
NON-CONDITIONED SPACE
NON-CONDITIONED GARAGE
Rigid backing to support insulation
D1.23Dec. 5, 2011
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Masonry Structure
TransitionMembrane
ArchitecturalMasonry
Steel Structure
Concrete Block
Masonry Tie
CD1.1Jan. 4, 2012
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Masonry Lower
Caulking
Flashing Membrane
ArchitecturalMasonry
Weep Hole
Transition Membrane
Optional Waterproof Coating
Type 1 Vapour Barrier
Concrete Block
Masonry Tie
CD1.2Jan. 4, 2012
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Masonry Upper
ArchitecturalMasonry
Air Vent
TransitionMembrane
Concrete Block
Plate Cussion
Steel Structure
Waterproof Coating
Vapour Barrier
Fiber Board
Fiber Board
Roof Insulation
Masonry Tie
CD1.3Jan. 4, 2012
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Masonry Opening
ArchitecturalMasonry
Flashing Membrane
Concrete Block
Wood Blocking
Wood Blocking
Caulk
Caulk
Masonry Tie
CD1.4Jan. 4, 2012
Window
TransitionMembrane
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Gypsum Board Structure
ArchitecturalMasonry
Masonry Tie
ExteriorGypsum Board
Steel Structure
Transition Membrane
Insulation
Vapour Barrier
Gypsum Board
Metal Framing
Steel Structure
CD1.6Jan. 4, 2012
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Gypsum Board Lower
Metal Facing
Flashing
CementParging
Z Bar
Metal Liner
Steel Structure
Concrete Foundation
CD1.5Jan. 4, 2012
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Gypsum Board Floor/Wall
ArchitecturalMasonry
TransitionMembrane
Metal Framing
ExteriorGypsum Board
Gypsum Board
Type 1 Vapour Barrier
Insulation
Gypsum Board
Type 1 Vapour Barrier
Insulation
FireProofing
Steel Structure
CD1.7Jan. 8, 2012
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Gypsum Board Floor/Wall
ArchitecturalMasonry
TransitionMembrane
Metal Framing
ExteriorGypsum Board Gypsum Board
Caulk
Caulk
Type 1 Vapour Barrier
Insulation
Gypsum Board
Type 1 Vapour Barrier
Insulation
Concrete Structure
CD1.8Jan. 8, 2012
Insulthane a Division of Elastochem 37 Easton Rd Brantford, On N3P 1J4, Canada
www.Elastochem-ca.com/insulthane
Wall Section, Wood-Framed MasonryLower Section
ArchitecturalMasonry
Weephole
ConcreteFoundation
CementParging
Flashing
Masonry Tie
Gypsum Board
Insulation
Gypsum Board
Vapour Barrier
Furring
CD1.9Jan. 4, 2012
Insulthane a Division of Elastochem a
www.Elastochem-ca.com/insulthane
Note:Closed-cell spray foam insulation thickness to meet local code requirements.
Minimum thickness of 2" (50mm) required when installed as a vapor retarder.
CONDITIONEDSPACE
NON-CONDITIONED SPACE
CONDITIONED SPACE
CONDITIONED SPACE
Sealant
Wind baffle may be requiredto obtain full insulation depth
Sealant
Sealant
Sealant
Rigid backing tosupport insulation
Sealant
D1.1aDec. 5, 2011