Insulated Flooring Below Beam
Benefits■■ Thermal insulation has a lifelong efficiency■■ Dimensionally stable■■ No nutritional value for insects and vermin■■ Non-toxic, non-irritant■■ 100% recyclable and Zero Ozone Depletion Potential■■ EPS insulated suspended floors have an A+ BRE Green Guide rating
■■ Euroclass B fire performance classification
Panel Details
The insulation used to produce the panels has a thermal resistance up to five times greater than lightweight thermal blocks, thus eliminating the need for additional insulation. The shape of the panels has been carefully developed to minimize thermal bridging at the T Beams; when installed, the panels form an unbroken wall to wall layer of insulation below the floor beams. The system is quick and easy to install and produces a floor with an excellent thermal insulation value achieving as low as 0.1W/m2K.
Certification
The product is manufactured to the requirements of BS EN 13163 2001 and under a quality management system. BS EN ISO 9001:2000 and is Agrément Approved.
This system comprises of 3 EPS components:
■ Full insulation unit
■ Half insulation unit
■ Starter insulation unit
Longley Concrete’s insulated below beam flooring system comprises of a rigid insulation panel manufactured from lightweight, closed cell EPS, pre-stressed concrete T Beams and a structural concrete topping. The floor serves as a temporary framework to lay the structural topping and also acts as the main insulant for the finished floor.
Insulated Flooring – Below Beam
Typical Full Unit
All units can be cut with a fine-tooth saw or hot wire cutter on site if needed.
Typical Starter Unit
Typical Half Unit
London 0203 553 8044 Yorkshire 01924 464283
Product Information Indicative U-values of suspended below beam insulated floors
Fire Performance
Euroclass B classification can be expected.
Building Regulations
Changes to Approved Document L (ADL) were implemented in April 2006. Houses designed to the previous regulations will require radical changes in order to meet the required carbon dioxide emission reductions. A minimum reduction of 20% in CO2 emissions is required for the whole building.
The limiting U-value for the ground floor is 0.25 W/m2K. However, U-values as low as 0.10 W/K can be achieved with increased EPS panel thickness.
Underfloor Heating
Underfloor heating may be used in conjunction with the below beam insulated system. However, a minimum of 60 mm concrete topping is required above the top of the underfloor heating pipe.
Toppings
Extensive testing has been carried out on the composite action of this flooring system incorporating steel reinforced concrete and fibre reinforced concrete.
The finished topping specification is flexible to accommodate a wide variety of floor loadings to suit the application.
Visit www.longley.uk.com for details.
Property Full Unit
Half Unit
Starter Unit
Thermal Conductivity (W/m2K): White Panel 0.038 0.038 0.038
Thermal Conductivity (W/m2K): Platinum Panel 0.030 0.030 0.030
Panel Thickness (mm): Total Panel 235 235 235
Panel Length (mm): Total Panel 1200 1200 1200
Panel Width (mm): Top 540 270 300 (max)
Panel Width (mm): Standard Bottom 705 435 465
Perimeter: Area Ratio P/A
298 mm Platinum Panel
394 mm Platinum Panel
0.5 0.14 0.10
0.6 0.14 0.10
0.7 0.14 0.10
0.8 0.14 0.10
0.9 0.15 0.10
www.longley.uk.com [email protected]
Handling and Storage
Packs are delivered to site wrapped in polythene. Store panels in original packaging, under cover and protected from direct sunlight. Keep boards above ground level and out of contact with solvents and materials containing volatile organic compounds such as coal tar, pitch or creosote. Do not expose to naked flame or other ignition sources during storage or installation.
Services
Do not use Longley’s insulated flooring in direct contact with PVC – sheathed electrical cables, hot water or pipes. Electrical cables should be enclosed in suitable conduit.
Health and Safety
The units are not designed for foot traffic and where access is required timber boards should be used. The product is chemically inert and requires no special treatment
Using the insulated flooring product in a suspended ground floor is an effective alternative to a Beam & Block construction.