instruments earth resistance · pdf filetlb page no. 31 53 53 47 46 45 23 27 14 22 16 18 44...
TRANSCRIPT
INSTRUMENTS
DIGITAL MULTIMETERS
- Selection Guide ................................................................................................... 10-11
- Multimeters ......................................................................................................... 12-18
- Accessories ............................................................................................................... 19
CLAMP METERS
- Selection Guide ................................................................................................... 20-21
- Clamp Meters ...................................................................................................... 22-29
EARTH RESISTANCE TESTERS
- Selection Guide ........................................................................................................ 30
- Earth Resistance Testers ....................................................................................... 31-32
- Compliance Kits ........................................................................................................ 33
INSULATION TESTERS
- Selection Guide ................................................................................................... 34-35
- Insulation Testers ................................................................................................. 36-40
- PSC Loop Testers ....................................................................................................... 41
- ELCB/Polarity/Phase Rotation Testers .................................................................... 42-47
- Miscellaneous and Voltage Testers ....................................................................... 47-51
- Surge Protection ....................................................................................................... 48
COMPLIANCE TESTERS
- Selection Guide ........................................................................................................ 52
- Compliance Testers ................................................................................................... 53
POWER ANALYSERS
- Selection Guide ........................................................................................................ 54
- Power Analysers ....................................................................................................... 55
- Accessories ............................................................................................................... 56
PHOTOVOLTAIC INSTRUMENTS
- Selection Guide ................................................................................................... 57-58
- Solutions for Performance and Troubleshooting ........................................................ 58
- Selection Guide - Accessories ............................................................................... 59-60
- Photovoltaic Instruments ...................................................................................... 61-62
- Calibrators ................................................................................................................ 63
- Test Leads ............................................................................................................ 64-66
- Cable Avoidance Detectors ....................................................................................... 67
- Cable Route Tracers .................................................................................................. 68
- High Voltage Testers ............................................................................................ 69-72
- Automotive Testers .............................................................................................. 73-74
- Tachometer testers .................................................................................................... 75
- Digital Timers ....................................................................................................... 76-77
THERMOMETERS
- Selection Guide ........................................................................................................ 78
- Selection Guide - Temperature Probe (Type K) .......................................................... 78
- Thermometers ..................................................................................................... 79-82
- Environmental Testers ............................................................................................... 79
THERMAL IMAGERS
- Selection Guide ........................................................................................................ 83
- Thermal Imagers .................................................................................................. 84-85
Instruments 1.0
Certificate of Compliance Test Instruments Selection GuideInstruments1.0
+ Indication only
NOTE:
Testing of operation of earth leakage test button, no instrument is required.
The above is only a guide as many other instruments can be used.
INSTRUMENTMAC-ROG3
T1105 T1120 T1125 T1132 T1151 T1800 T1805 T1820 T1825 T1832 T1851 T2000
PAGE NO. 53 32 32 41 36 37 36 31 32 41 36 37 29
Continuity of bonding • • • • • •
Resistance of earth continuity conductor
• • • • • •
Continuity of ring circuits (if applicable)
• • • • • •
Earth loop impedance test: at main switch
• • •
Prospective short-circuit current at point of control (PSCC) for sub-distribution boards
• • •
Elevated voltage between incoming neutral and external earth
• •+ •+
Earth resistance at electrode (if required)
• • • • • •
Insulation resistance • • • • • •
Voltage at main distribution board with no load for each phase to neutral
•
Voltage at main distribution board with load (as calculated for full load) for each phase
•
Voltage at available load (worst condition as calculated for full load) for each phase to neutral
• • •
Operation of earth leakage units
•
Polarity of points of consumption
• •
Phase rotation at points of consumption for three-phase systems
•
All switching devices, make-and-break circuits
• • • • • •
1.0Certificate of Compliance Test Instruments Selection GuideInstruments
InstrumentMAC-ROG3
T1105 T1120 T1125 T1132 T1151 T1800 T1805 T1820 T1825 T1832 T1851 T2000 T416 T419 T60 T70 T860 T890TBM076
TBM079
TBM252
TBM 3030
TBM811
TBM878
TEL11 TEL28TEL 2SC
TEL1 TLB
Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44
Continuity of bonding • • • • • • • •
Resistance of earth continuity conductor • • • • • • • •
Continuity of ring circuits (if applicable) • • • • • • • • •
Earth loop impedance test:at main switch
• • • • •
Prospectiveshort-circuit current at pointof control (PSCC) for sub-distribution boards
• • • • •
Elevated voltage between incoming neutral and external earth • • • • • • • • • •+ •+ •+ •+
Earth resistanceat electrode(if required)
• • • • • • • •
Insulation resistance • • • • • • • •
Voltage at main distribution board with no load for each phase toneutral
• • • • • • • •
Voltage at main distribution board with load (as calculated for fullload) for each phase
• • • • • • • •
Voltage at available load (worst condition as calculated for full load)for each phase to neutral
• • • • • • • • •
Operation of earth leakage units • • • • • • •
Polarity of pointsof consumptio
• • • • • •
Phase rotation at points of consumption for three-phase systems • • • • • • •
All switching devices, make-and-break circuits • • • • • • • • • •
1.0
10
Digital Multimeters - Selection GuideInstruments
FEATURES T820 T835 T1300H T235H T48 TBM805 TBM807 TBM869 TBM252
PAGE 12 12 12 13 13 13 14 14 14
LCD Display (Counts) 1999 1999 1999 1999 1999 4000 4000 5000 000 6000
LCD Display (Digits) 31/2
31/2
31/2
31/2
31/2
33/4
35/6
54/5
35/6
TRUE RMS • • •
Transistor HFE • •
Logic • •
Max AC Voltage (V) 600 500 500 750 750 1000 1000 1000 1000
Max DC Voltage (V) 600 500 500 1000 1000 1000 1000 1000 1000
Max AC Current (A) 20 20 10 10 10 8
Max DC Current (A) 10 10 10 20 20 10 10 10 8
Max Resistance (Ω) 20M 20M 200M 200M 200M 40M 40M 60M 60M
Continuity Beeper • • • • • • • • •
Diode Test • • • • • • • • •
Auto Range • • • •
Frequency (Hz) 200K 1M 1M 1M 1M
Capacitance (F) 200µ 200µ 3000µ 3000µ 25m 3000µ
Temperature (ºC) 1000 1000 1000 300 1000 1000
Min/Max DISPLAY MAX MAX • •
Data Hold • • • • • • • • •
Crest (Peakhold) •
Backlight • • • • •
Splash and Dust Proof • • • •
Transient Proof (kV) 6.5 6.5 12 6.0
Relative Reference • • • •
Bargraph • •
Auto Power Off (APO) • • • • •
USB Interface • •
Data Logger
EF Detect •
Safety Category
Intrinsically Safe
Dual DISPLAY •
Fuse: mA Rating 250mA 250V 250mA 250V 250mA 250V 250mA 250V 250mA 250V 44mA 1000V 630mA 500V
Fuse Size (mm) 5 x 20 5 x 20 5 x 20 5 x 20 5 x 20 10 x 37 6 x 32
Fuse: A Rating 12A 250V 11A 1000V 10A 600V
Fuse: Size (mm) 5 x 20 6 x 25 6 x 25 10 x 37 10 x 37
Lifetime Warranty
CAT III 600V CAT III 600V CAT III 600V CAT IV 1000V CAT III 600V
CAT IV 300V
CAT II 1000VCAT II 1000V
CAT IV 600V
CAT II 1000V
CAT IV 600V
CAT II 1000V
CAT III 600V
CAT II 1000V
CAT III 600V
* LIFETIME WARRANTY
1.0
11
Digital Multimeters - Selection GuideInstruments
TBM239R TBM829* TBM525 TBM811* TBM812* TBM811XEX* TBM812XEX* TBM319 TBM878 T8209
15 15 15 16 16 17 17 18 18 18
6000 6000 10 000 6000 6000 6000 10 000 6000 6000 3999
35/6
39/10
39/10
39/10
39/10
39/10
39/10
35/6
35/6
3
• • • • • • •
• •
1000 1000 1000 1000 1000 1000 1000 1000 1000 750
1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
10 10 10 10 10 10 10 10 10 10
10 10 10 10 10 10 10 10 10 10
60M 60M 60M 60M 60M 60M 60M 60M 60M 40M
• • • • • • • • • •
• • • • • • • • • •
• • • • • • • • • •
50K 1M 1M 1M 1M 1M 1M 1k 5k 1k
2000µ 20m 25m 20m 20m 20m 20m 200µ 30m 100µ
400 1000 1000 1000 1000 1000
• • • • •
• • • • • • • • • •
• •
• • • •
• • • • • • • • • •
6.0 12 12 12 12 12 12 12 12
• • • • • • • • • •
• • • • • • • •
• • • • • • • • • •
• • • • • •
•
• • •
• • • • •
• • • • • • • •
44mA 1000V 44mA 1000V 1A 600V 1A 600V 44mA 1000V 44mA 1000V 630mA 500V 630mA 500V
10 x 37 10 x 37 10 x 35 10 x 35 10 x 37 10 x 37 6 x 32 6 x 32
11A 1000V 11A 1000V 11A 1000V 10A 600V 10A 600V 11A 1000V 11A 1000V 6.3A 500V 6.3A 500V 10A 600V
6 x 37 6 x 37 6 x 37 6 x 37 6 x 37 6 x 37 6 x 37 6 x 37 6 x 37 6 x 37
• • • • •
CAT III 600V
CAT IV 300V
CAT II 1000V
CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT II 1000V CAT III 1000V CAT III 600V
1.0
12
Digital MultimetersInstruments
Feature Parameter Accuracy
DC Voltage 200mV, 2, 20, 200, 600V ±0.5% + 4 Digit
AC Voltage 200, 500V ±1.2 % + 10 Digit
DC Current 200mA, 2mA, 20mA, 200mA,10A ±1.0 % + 2 Digit
Resistance 200, 2k, 20k, 200k, 20MΩ 0.8% + 10 Digit
Temperature 20°C to 1000°C ±1.0 % + 3 Digit
Counts 3 -1/2 Digits 1999 Counts
Technical Overview
Feature Parameter Accuracy
DC Voltage 200mV, 2, 20, 20, 500V ±0.5% + 2 Digit
AC Voltage 200, 500V ±1.2% + 10 Digit
DC Current 2mA, 20mA, 200mA,10A 2m-200mA ±1% +2 Digit
Resistance 200, 2k, 20k, 200k, 200MΩ ±1% + 5 Digit
Counts 3 -1/2 Digits 1999 Counts
Technical Overview
Feature Parameter Accuracy
DC Voltage 200mV, 2, 20, 200, 600V ±0.5% + 4 Digit
AC Voltage 200, 600V ±1.2 % + 10 Digit
DC Current 200µ, 2mA, 20mA, 200mA,10A ±1.5 % + 3 Digit
Resistance 200, 2k, 20k ,200k ,20MΩ ±1.2% + 4 Digit
Counts 3 -1/2 Digits 1999 Counts
Technical Overview
Power Source 1 x 9V Battery
Model Specification
Power Source 1 x 9V Battery
Standard Accessories Temp Probe TBMTEMPPROBE
Model Specification
Power Source 1 x 9V Battery
Model Specification
CAT III 600V
CAT III 600V
CAT III 600V
T820• DIY • Large LCD display• Continuity• Diode
T835• DIY• Continuity• Diode • Data hold
T1300H• Electronic• Backlit• Diode• Continuity• Data hold
1.0
13
Digital MultimetersInstruments
Feature Parameter Accuracy
DC Voltage 200mV, 2mV, 20, 200, 1000V ±0.5% + 4 Digit
AC Voltage 20V, 200, 750V ±1.2 % + 10 Digit
DC Current 20mA, 200mA ,20A ±1.5 % + 3 Digit
Resistance 200, 20k, 200k,20MΩ, 200MΩ ±1.2% + 4 Digit
Temperature -20°C to 1000°C ±0.8 % + 4 Digit
Capacitance 20nF, 2nF, 2000µF ±2.5 % + 20 Digit
Counts 3 -1/2 Digits 1999 Counts
Technical Overview
Feature Parameter Accuracy
DC Voltage 200mV, 2, 20, 200, 1000V ±0.5% + 3 Digit
AC Voltage 200mV, 2, 20, 200, 750V ±0.8% + 5 Digit
DC Current 20µ, 200µ, 20mA, 200mA, 2A, 20A ±0.8% + 3 Digit
AC Current 200mA, 20A ±1.0% + 5 Digit
Resistance 200, 2k, 200k, 2M, 20M, 2000MΩ ±0.8 % + 3 Digit
Frequency 2k, 200kHz ±0.5% + 4 Digit
Temperature -20°C to 1000°C ±1.0% + 4 Digit
Capacitance 20nF, 200nF, 2µF, 20µF, 200µF 20nF-20µf ±2.5% +20 Digit
Counts 3 -1/2 Digits 1999 Counts
Technical Overview
Power Source 1 x 9V Battery
Standard Accessories Temp Probe TBMTEMPPROBE
Model Specification
Power Source 1 x 9V Battery
Standard Accessories Temp Probe TBMTEMPPROBE
Model Specification
TRMS
Power Source 2 x 1.5V AAA Batteries
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
DC Voltage 400mV, 4, 40, 400, 1000V ±1.0%+4 Digit
AC Voltage 400mV, 4, 40, 400, 1000V 4 -400V ±1.5% + 5 Digit, 1000V ±4.0% + 5 Digit
DC Current 400µ, 4000µ, 40mA, 400mA, 4.10A ±1.2% + 3 Digit
AC Current 400µ, 4000µ, 40mA, 400mA, 4.10A ±1.8% + 4 Digit
Resistance 400, 4k, 40k, 400k, 4M, 40MΩ ±2.0% + 4 Digit
Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5% + 6 Digit
Frequency 50k, 500k, 5k, 50k, 500k, 1MHz ±0.5% + 4 Digit
Counts 3 -3/4 Digits 4000 Counts
Technical Overview
CAT III 600V
T235H • Electrician’s• Backlit• Data hold • Capacitance
T48• Electronic • Backlit• Capacitance• Inductance
TBM805• Electrician’s • Splash proof • Beep guard• Rugged construction
• Data hold• Min/Max• Relative zero
1.0
14
Digital MultimetersInstruments
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Temp Probe TBMTEMPPROBE
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
DC Voltage 400mV, 4, 40, 400, 1000V ±1.0%+4 Digit
AC Voltage 400mV, 4, 40, 400, 1000V 4 -400V ±1.5% + 5 Digit, 1000V ±4.0% + 5 Digit
DC Current 400µ, 4000µ, 40mA, 400mA, 4.10A ±1.2% + 3 Digit
AC Current 400µ, 4000µ, 40mA, 400mA, 4.10A ±1.8% + 4 Digit
Resistance 400, 4k, 40k, 400k, 4M, 40MΩ ±2.0% + 4 Digit
Temperature 20°C to 300°C ±2.0% + 3°C
Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5% + 6 Digit
Frequency 50k, 500k, 5k, 50k, 500k, 1MHz ±0.5% + 4 Digit
Counts 3 -3/4 Digits 4000 Counts
Technical Overview
• Electrician’s• Beep guard• Data hold
• Min/Max• Relative zero
CAT III 600V
TRMS
Feature Parameter Accuracy
DC Voltage 60mV, 600mV, 6, 60, 600, 1000V ±0.2% + 3 Digit
AC Voltage 60mV, 600mV, 6, 60, 600, 1000V ±0.2% + 3 Digit
DC Current 600µ, 6000µ, 60mA, 600mA, 6.8A ±0.5% + 3 Digit
AC Current 600µ, 6000µ, 60mA, 600mA, 6.8A ±1.0% + 3 Digit
Resistance 600, 6k, 60k, 600k, 6M, 60MΩ ±1.2% + 4 Digit
Temperature -50ºC to 1000ºC
Capacitance 60nF, 600nF, 6µ, 60µ,600µ,3000µF ±2.0% + 5 Digit
Frequency 5Hz - 1MHz ±0.003% + 2 Digit
Auto Check 1V - 1000 V AC/DC
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
TBM252• USB Interface• Non-contact EF detection
• Separate battery compartment
Power Source 1.5V AAA Battery
Standard Accessories Temp Probe TBMTEMPPROBE
Optional Accessories USB Cable and Software TBU20X SEE PG 19, USB Adaptor SEE PG 19,
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
DC Voltage 500mV, 5, 50, 500, 1000V 0.02% + 2 Digit
AC Voltage 500mV, 5, 50, 500, 1000V 1.2% + 40 Digit (20hz-45hz)
DC Current 500µ, 5000µ, 50mA, 500mA, 5.10A 0.15% + 20 Digit (0.5% + 50 Digit att 500µA)
AC Current 500µ, 5000µ, 50mA, 500mA, 5.10A 0.5% + 50 Digit
Resistance 500, 5k, 50k, 500k, 5m, 50mΩ 0.07% + 10 Digit
Temperature -50ºC to 1000ºC 0.3% + 1.5ºC
Capacitance 50nF, 500nF, 5µ, 500µ, 25mf 0.8% + 3 Digit
Frequency Line: Logic
10Hz to 3kHz 0.002% + 4 Digit
Counts 5 -4/5 Digits 500000 Counts
Technical Overview
TBM869• Probe input warning• Crest mode
• Duty cycle• Dual display
Power Source 1 x 9V Battery
Standard Accessories Temp Probe TBMTEMPPROBE
Optional Accessories USB Cable and Software TBU86X SEE PG 19
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
TBM807
CAT IV 1000V
TRMS
CAT III 600V
1.0
15
Digital MultimetersInstruments
CAT IV 300V
TRMS
Power Source 1 x 9V Battery
Standard Accessories Temp Probe TBMTEMPPROBE
Optional Accessories USB Cable and Software TBU86X SEE PG 19, Magnetic Hanger TBMH01
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
DC Voltage 60mV, 600mV, 6, 600, 1000V 0.08% + 2 Digit
AC Voltage 60mV, 600mV, 6, 600, 1000V 2.0% + 3 Digit
DC Current 600µ, 6000µ, 60mA, 600mA, 6A,10A 0.2% + 4 Digit
AC Current 600µ, 6000µ,60mA, 600mA, 6,10A 1.0% + 4 Digit
Resistance 0.1Ω - 60MΩ 1.5% + 5 Digit
Temperature -50ºC to 1000ºC 0.3% + 2ºC
Capacitance 60nF, 600nF, 6µ, 60µ, 600µ, 20mF 5.0% + 5 Digit
Frequency 5Hz - 1MHz 0.004% + 4 Digit
Counts 3 -9/10 Digits 6000 Counts
Technical Overview
TBM239R
TBM829• Splash/Drop proof• USB interface• Dual display
• Non-contact EF• Auto check• Crest (Peak-hold)
• Phase rotation• VFD V Hz• Hz of line level voltage
• Probe input warning• Non-contact EF detection
TBM525• Datalogger• 87 000 points single display mode• 43 000 points dual display mode
• USB interface• Non-contact EF detection
Feature Parameter Accuracy
DC Voltage 60mV, 600mV, 6, 600, 1000V 0.08% + 2 Digit
AC Voltage 60mV, 600mV, 6, 600, 1000V 0.08% + 2 Digit
DC Current 600µ, 6000µ, 60mA, 600mA, 6A,10A 0.8% + 6 Digit
AC Current 600µ, 6000µ, 60mA, 600m, 6,10A 0.8% + 6 Digit
Resistance 0.1Ω - 60MΩ 0.8% + 10 Digit
Temperature -50ºC to 1000ºC 0.3% + 2ºC
Capacitance 60nF, 600nF, 6µ, 60µ, 600µ, 25mF 5.0% + 5 Digit
Frequency 5Hz to 1MHz 0.004% + 4 Digit
Counts 3 -9/10 Digits 10000 Counts
Technical Overview
Power Source 1 x 9V Battery
Standard Accessories Temp Probe TBMTEMPPROBE
Optional Accessories USB Cable and Software TBU86X SEE PG 19, Magnetic Hanger TBMH01
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
CAT III 1000V
TRMS
CAT IV 1000V
TRMS
Power Source 2 x 1.5V AAA Batteries
Optional Accessories Magnetic Hanger TBMH01
Certificates EN6101-1/2-2-030/-2-033
Model Specification
Feature Parameter Accuracy
DC Voltage 60mV, 600mV, 6000V, 60V, 600V, 1000V 0.03% + 2 Digit
AC Voltage 6V, 60V, 600V, 1000V 0.7% + 3 Digit
DC Current 200µA, 2000µA, 6A, 10A 0.7% + 3 Digit
AC Current 200µA, 2000µA, 6A, 10A 1.0% + 3 Digit
Resistance 600Ω - 60MΩ 0.3% + 2 Digit
Temperature -40ºC to 400ºC 1.0% + 1ºC
Capacitance 2000nF, 20µF, 200µF, 2000µF 1.5% + 2 Digit
Frequency 100Hz - 50KHz 0.03% + 2 Digit
Counts 3-5/6 Digits 6000 Counts
VDF ACV 10Hz - 440Hz, 600V, 1000V 2.0% + 3 Digit
Technical Overview
Power Source 1 x 9V Battery
Optional AccessoriesUSB Cable and Software TBU86X, USB Adaptor SEE PG 19, Magnetic Hanger TBMH01
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
1.0
16
Digital MultimetersInstruments
Feature Parameter Accuracy Protection
DC Voltage 60mV, 600mV, 6600, 1000V 0.08% + 2 Digit 1050Vrms, 1450V peak
AC Voltage 60mV, 600mV, 6, 600, 1000V 2.0% + 3 Digit 1050Vrms, 1450V peak
DC Current 600µ, 6000µ, 60m, 600mA, 6.10A 0.2% + 4 Digit 0.44A/1000V Fuse (IR10kA)11A/1000V Fuse (IR20kA)
AC Current 600µ, 6000µ, 60mA, 600mA, 6.10A 1.0% + 4 Digit0.44A/1000V Fuse (IR10kA)11A/1000V Fuse (IR20kA)
Resistance 40.1Ω - 60MΩ 1.5% + 5 Digit 1.2V DC open circuit
Capacitance 60nF, 600nF, 6µ, 60µ, 600µ, 20mF 5.0% + 5 Digit
Frequency 5Hz - 1MHz ±0.5% + 4 Digit
Input Warning
Transient 12kV surge
Protection (1.2/50 µs) surge
Counts 3 -9/10 Digits 6000 Counts
Technical Overview - TBM811 and TBM811XEX
Power Source 1 x 9V Battery
Optional AccessoriesUSB Cable and Software TBU86X, USB Adaptor SEE PG 19, Magnetic Hanger TBMH01
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy Protection
DC Voltage 60mV, 600mV, 6, 600, 1000V 0.08% + 2 Digit 1050Vrms, 1450V peak
AC Voltage 60mV, 600mV, 6, 600, 1000V 2.0% + 3 Digit 1050Vrms, 1450V peak
DC Current 600µ, 6000µ, 60mA, 600mA, 6.10A 0.2% + 4 Digit 0.44A/1000V Fuse (IR10kA)11A/1000V Fuse (IR20kA)
AC Current 600µ, 6000µ, 60mA, 600mA, 6.10A 1.0% + 4 Digit0.44A/1000V Fuse (IR10kA)11A/1000V Fuse (IR20kA)
Resistance 40.1Ω - 60MΩ 1.5% + 5 Digit 1.2V DC open circuit
Capacitance 60nF, 600nF, 6µ, 60µ, 600µ, 20mF 5.0% + 5 Digit
Frequency 5Hz - 1MHz 0.004% + 4 Digit
Input Warning
Transient 12kV surge
Protection (1.2/50 µs) surge
Counts 3 -9/10 Digits 6000 Counts
Technical Overview - and TBM812XEX
LIFETIME WARRANTY
CAT IV 1000V
TRMS
LIFETIME WARRANTY
CAT IV 1000V
TBM811• General Purpose• Splash/Drop proof• 1000V AC/DC• USB interface• Dual display• Backlit
TBM812• General Purpose• Splash/Drop proof• 1000V AC/DC• USB interface• Dual display• Backlit
1.0
17
Digital MultimetersInstruments
TBM811XEX Intrinsically Safe
• 1A/1kV (IR10kA) for µA and mA (1000V HRC Fuse) • 11A/1kV (IR20kA) for A (1000V HRC Fuse)
These meters comply to IEC SANS 60079-0:2000 and IEC SANS 60079-11:1999. which is an electrical apparatus for explosive gas atmospheres. Part 0 (general requirements) and Part 1 (intrinsic). The approved explosive protection rating of this equipment is suitable for use in Zone 1 hazardous area. Group I (coal mines) underground and Group II (surface).
Markings on meter:
• Ex ib I Mb• Ex ib IIC Gb • SAEx MS/09-200X • Ex ib falls under Zone 1 which is an area where flammable gas can occur in
normal operating conditionsLIFETIME WARRANTY
CAT IV 1000V
TBM812XEX Intrinsically Safe
• 1A/1kV (IR10kA) for µA and mA (1000V HRC Fuse) • 11A/1kV (IR20kA) for A (1000V HRC Fuse)
These meters comply to IEC SANS 60079-0:2000 and IEC SANS 60079-11:1999. which is an electrical apparatus for explosive gas atmospheres. Part 0 (general requirements) and Part 1 (intrinsic). The approved explosive protection rating of this equipment is suitable for use in Zone 1 hazardous area. Group I (coal mines) underground and Group II (surface).
Markings on meter:
• Ex ib I Mb• Ex ib IIC Gb • SAEx MS/09-200X • Ex ib falls under Zone 1 which is an area where flammable gas can occur in
normal operating conditions
LIFETIME WARRANTY
CAT IV 1000V
TRMS
Technical Overview see TBM811
Technical Overview see TBM812
TBM811XEX• General Purpose• Splash/Drop proof• 1000V AC/DC• USB interface• Dual display• Backlit
TBM812XEX• General Purpose• Splash/Drop proof• 1000V AC/DC• USB interface• Dual display• Backlit
Power Source 4 x 1.5V AA Batteries
Standard AccessoriesTemp Probe TBMTEMPPROBE, Croc clips TBM878CLIP, Test Lead Adaptor TBM878TIPS, Test Lead TBM878LEAD, Industrial Test Probe TBM878PROBE
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
DC Voltage 60mV, 600mV, 6, 600, 1000V 0.09% + 3 Digit
AC Voltage 60mV, 600mV, 6, 600, 1000V 2.0% + 3 Digit
DC Current 60mA, 400mA 0.4% + 3 Digit
AC Current 60mA, 400mA 1.5% + 3 Digit
Resistance 600, 6k, 60k, 600k, 6M, 60MΩ 1.5% + 3 Digit
InsulationResistance
50V(3M-55MΩ),100V(3M-110MΩ), 250V(3M-275MΩ)550V(3M-550MΩ), 1000V (3M-25GΩ)
1.5% + 3 Digit
Temperature -50ºC to 1000ºC 9% + 2.0ºC
Capacitance 3µ,30µ,300µ,3000µF,30mF 10% + 5 Digit
Frequency 10Hz - 5KHz 0.02% + 4 Digit
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
1.0
18
Digital MultimetersInstruments
Feature Parameter Accuracy
DC Voltage 60mV, 600mV, 6, 600, 1000V 0.4% + 3 Digit
AC Voltage 60mV, 600mV, 6, 600, 1000V 2.0% + 5 Digit
DC Current 600µ, 6000µ, 60mA, 600mA, 6, 10A 0.7% + 3 Digit
AC Current 600µ, 6000µ, 60mA, 600mA, 6, 10A 2.2% + 5 Digit
Resistance 600, 6k, 60k, 600k, 6M, 60MΩ 0.5% + 5 Digit
Temperature -50ºC to 1000ºC 0.5% + 3 Digit
Capacitance 6µ, 60µ, 600µ, 2000µF 2.0% + 5 Digit
Frequency 10Hz - 1kHz 0.1% + 3 Digit
IP-RPM 240-20000RPM (Inductive)
IG-RPM 60-20000RPM (Contact)
DWELL 0.0º - 360º 1.2º/kRPM + 1 Digit
FUEL INJECTOR 0.05ms - 250.0ms 0.05ms + 1 Digit
Technical Overview
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Temp Probe TBMTEMPPROBE, Banana Plug BKP60, Inductive Pickup Clip BP300
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
DC Voltage 400mV, 4, 40, 400, 1000V ±0.7% + 2 Digit
AC Voltage 4, 40, 400, 750V ±1.0% + 3 Digit
DC Current 400µA, 400mA, 10A ±2.0% + 10 Digit
AC Current 400µA, 400mA, 10A ±3.0% + 10 Digit
Resistance 400, 4k, 40k, 400k, 40MΩ ±2.0% + 5 Digit
Temperature ±20°C to 1000°C ±3.0% + 5 Digit
Capacitance 4.40nF, 400nF, 4µ, 40, 100µF ±3.0% + 3 Digit
Frequency 10Hz - 1kHz ±2.0% + 5 Digit
Humidity 20~95% RH ±5.0% RH
Sound Level (dB) 40~100dB ±3.5% at 94dB
Illuminance 1~40000 Lux ±5.0% + 10 Digit
Duty Cycle 0.1~99.9% ±3.0%
Counts 3 Digits 3999 Counts
Technical Overview
Power Source 3 x 1.5V AAA Batteries
Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
CAT II 1000V
TRMS
CAT III 1000V
dB
%Rh
VΩA
CAT III 600V
TBM319 Automotive Tester• Splash/Drop proof• Selectable 4-stroke /2-stroke
• Sensitivity on RPM• Selectable 1 to 12 cylinders
TBM878 Insulation/Combination• Industrial test probe• Earth bond resistance
• VFD AC Voltage• Relative zero
T8209 Multipurpose 5-in-1• Test probe input warning lights • Diode test
Code TBRUSB TBM135 TBM157 TBM195 TBM197
Page No. 19 25 29 28 29
TBU13X
• • •
TBU19X
• •
Code TBRUSB TBM252 TBM811 TBM812 TBM525 TBM829 TBM869
Page No. 19 14 17 16 15 15 14
TBU20X
• •
TBU86X
• • • • •
Free Software updates available: www.brymen.com/product-html/software-download/
1.0
19
AccessoriesInstruments
TBRUSB (USB Adaptor) - Fits TBU20X, TBU13X, TBU19X
Digital Multimeters
Clamp Meters
TBU Software• Optical interface adaptor• USB Cable and software
1.0
20
Digital Clamp Meters - Selection GuideInstruments
FEATURES TBM3030 TM175D TBM072 TBM076 TBM086 T98 T260D TBM116 TBM118 TBM135 T77N
PAGE 22 22 22 23 23 23 24 24 24 25 25
MAX AC Current (A)
600 600 600 600 1000 1000 1000 1000 2000 1000 100
MAX DC Current (A)
2
MAX AC Voltage (V)
600 600 600 600 1000 750 750 600 600 600
MAX DC Voltage (V)
600 600 600 600 1000 1000 1000 600 600 600
MAX Resistance (Ω)
40M 6M 60k 60k 60k 2k 2M 40M 6M 1k
Jaw Size (mm)
26 30 30 30 51 42 60 45 45 45 40
Temperature(°C)
400 400 400
Continuity • • • • • • • • • •
Frequency (Hz)
100k 1000k 100k 100k 100k 30k 500
Capacitance(F)
3000µ 2500µ 2500µ 2500µ 2000µ 2000µ
Diode • • • • • • • • • •
Display (Counts)
4000 4000 6000 6000 6000 1999 1999 4000 6000 6000 6000
Blacklight • • • • • • • •
Auto Range • • • • • • • • •
Data Hold • • • • • • • • • • •
Min/MaxDisplay
• • • • • • • • •
AmptipTM • • • •
TRUE RMS • • • • • • • •
Data Logging
Safety Category
CAT III 300V CAT III 600VCAT IV 300V CAT III 1000VCAT III 600V CAT III 600V CAT III 600V CAT III 600V CAT III 600V CAT III 600V CAT III 300V
1.0
21
Digital Clamp Meters - Selection GuideInstruments
TF3000 T223 TBM061 TBM062 TBM079 T8056 TBM162 TBM089 T2608 TBM195 TBM197 TBM157
25 26 26 26 27 27 27 28 28 28 29 29
3000 100 400 400 600 1000 800 1000 1500 2000 2000 1000
100 400 400 600 1000 1000 1000 2000 2000 2000
600 600 600 600 700 600 1000 750 1000 1000 600
600 600 600 600 1000 600 1000 1000 1000 1000 600
10k 40M 40M 60k 40M 40M 60k 40M 40M 40M 999.9
110 12.5 30 30 35 42 50 51 57 55 55 45
400 750 400 1000
• • • • • • • • • • •
500 100k 100k 400 100k 1000k 400k 400k 400 400 500
3000µ 3000µ 2500µ 40µ 3000µ 2500µ 40µ 2000µ 2000µ
• • • • • • • • • •
3000 4 Digits 4000 4000 6000 4000 4000 6000 4000 6000 6000 6000
• • • • • • •
• • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • • • • • • •
• •
• • • • • • • •
• • •
CAT IV 600V CAT III 300V CAT III 600V CAT III 600V CAT III 600V CAT III 600V CAT III 600V CAT IV 600V CAT III 600VCAT IV 1000VCAT IV 1000VCAT III 1000V
1.0
22
Digital Clamp MetersInstruments
Feature Parameter Accuracy
AC Current 40, 600A ±1.9%+ 8 Digit
DC Current
AC Voltage 4, 40, 400, 600V 4.40, 400V ±1.5% + 5 Digit, 600V ±2.0% + 5 Digit
DC Voltage 400mV, 4, 40, 400, 600V ±1.0%+ 4 Digit
Resistance 400, 4k, 40k, 400k, 4M, 40MΩ4k, 40k, 400kΩ ±0.6%+4 Digit, 4MΩ ±1.0% + 4 Digit, 40MΩ ±2.0% + 4 Digit
Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5% + 6 Digit
Frequency 5Hz to 100kHz ±0.5% + 4 Digit
Counts 3 -3/4 Digits 4000 Counts
Technical Overview
Feature Parameter Accuracy
AC Current 40, 600A ±1.8%+ 5 Digit
DC Current
AC Voltage 4, 40, 400, 600V 4.40, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit
DC Voltage 400mV, 4, 40, 400, 600V ±1.0%+ 5 Digit
Resistance 600, 6kΩ, 60kΩ 1.0% + 5 Digit
Frequency 5Hz to 100kHz ±0.5% + 4 Digit
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
Power Source 1 x 3V Battery CR2032
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
CAT III 300V
TRMS
AmpTip™
CAT IV 300V
TBM3030 600A AC• Jaw size: 26mm• Large LCD display• Diode
• Continuity• Relative zero• Data hold
Feature Parameter Accuracy
AC Current 60-600A 1.5% + 5 Digit
DC Current 200mA, 2A 1.0% + 5 Digit
AC Voltage 4, 40, 400, 600V 1.0% + 5 Digit
DC Voltage 400mV, 4, 40, 400, 600V 1.0% + 5 Digit
Temperature -40º to 400º -40º - 100º 1.0% + 0.8º, 100º - 400º, 1% + 1º
Resistance 600Ω, 6MΩ600kΩ, 6kΩ, 60kΩ, 1.0% + 5 Digit, 600kΩ, 60MΩ 1.5% + 5 Digit
Capacitance 5200nF, 2500µF 2.0% + 4 Digit
Frequency 10Hz to 1000kHz 0.5% + 4 Digit
Counts 3 -3/4 Digits 4000 Counts
Technical Overview
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1. EMC EN61326-1:2013. Certificate of Conformance
Model Specification
TRMS
AmpTip™
CAT IV 300V
TBM175D 600A AC• Jaw size: 30mm• AmptipTM
• Rotary selector switch
• Dual display• Non-contact EF detection• VFD, V & Hz feature
TBM072 600A AC• Jaw size: 30mm• AmptipTM • Large LCD display • Rotary selector switch
• Continuity• Data hold• Non-contact EF detection
1.0
23
Digital Clamp MetersInstruments
Feature Parameter Accuracy
AC Current 40, 600A ±1.8%+ 5 Digit
DC Current
DC Voltage 400mV, 4, 40, 400, 600V ±1.0%+ 5 Digit
AC Voltage 4, 40, 400, 600V 440, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit
Resistance 600, 6kΩ, 60kΩ 600kΩ, 6kΩ, 60kΩ, ±1.0% + 5 Digit
Temperature -40°C to 400°C ± 1% - 0.8°C, 100°C - 400°C ±1.0% - 1°C
Frequency 5Hz to 100kHz ±0.5% + 4 Digit
Capacitance 200µ, 2500µF ± 2% + 4 Digit
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
Feature Parameter Accuracy
AC Voltage 600, 1000V ±1.8%+ 5 Digit
DC Voltage 600, 1000V
AC Current 60, 600, 1000A 4, 40, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit
DC Current ±1.0%+ 5 Digit
Resistance 600, 6kΩ, 60kΩ4k, 40k, 400kΩ ±0.6% +4 Digit, 4mΩ ±1.0% + 4 Digit, 40mΩ ±2.0% + 4 Digit
Temperature -40°C to 400°C ± 1% - 0.8°C, 100°C - 400°C ±1.0% - 1°C
Frequency 5Hz to 100kHz ±0.5% + 4 Digit
Capacitance 200µ, 2500µF ± 2% + 4 Digit
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
Feature Parameter Accuracy
AC Current 20, 200, 1000A ±2.0% + 5 Digit
DC Current
AC Voltage 750V ±1.0% + 5 Digit
DC Voltage 1000V ±1.0% + 2 Digit
Resistance 200, 2000Ω ±1.0% + 3 Digit
Temperature -40°C to 750°C ±1.0% + 5 Digit
Counts 3 -1/2 Digits 1999 Counts
Technical Overview
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 1 x 9V Battery
Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
TRMS
AmpTip™
CAT IV 300V
TRMS
AmpTip™
CAT III 1000V
CAT III 600V
TBM076 600A AC• Jaw size: 30mm• AmptipTM
• 3-Phase rotation for mains and motor• Non-contact EF detection
• Rotary selector switch• Continuity• Data Hold
TBM086 1000A AC• Jaw size: 51mm• AmptipTM
• 3-Phase rotation for mains and motor
• Non-contact EF detection• Rotary selector switch• Peak RMS 80ms in-rush current
T98 1000A AC• Jaw size: 42mm• Backlit• Continuity• Data hold
1.0
24
Digital Clamp MetersInstruments
Feature Parameter Accuracy
DC Current
AC Current 20, 200, 1000A ±2% + 5 Digit
DC Voltage 200mV, 20, 200, 1000V ±0.5% + 1 Digit
AC Voltage 200, 750V ±1.2% + 10 Digit
Resistance 200, 2k, 20k, 200k,2MΩ ±1.0% + 2 Digit
Counts 3 -1/2 Digits 1999 Counts
Technical Overview
Feature Parameter Accuracy
DC Current
AC Current 400, 2000A 1.5% + 5 Digit
DC Voltage 6, 60, 600V 2% + 5 Digit
AC Voltage 660, 600V 1.5% + 5 Digit
Resistance 6k, 60k, 600k, 6MΩ 1.2% + 4 Digit
Frequency 10 to 50kHz 0.5% + 4 Digit
Capacitance 100nF, 1000nF, 10µ, 100µ, 2000µF 3.5% + 5 Digit
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
Feature Parameter Accuracy
DC Current
AC Current 400, 1000A ±1.8%+ 5 Digit
DC Voltage 400mV, 4, 40, 600V ±1.0%+ 5 Digit
AC Voltage 4, 40, 400, 600V ±4, 40, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit
Resistance 400, 4k, 40k, 400k, 40MΩ4k, 40k, 400kΩ ±0.6% +4 Digit , 4mΩ ±1.0% + 4 Digit, 40mΩ ±2.0% + 4 Digit
Counts 3 -3/4 Digits 4000 Counts
Technical Overview
Power Source 1 x 9V Battery
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
CAT III 600V
TRMS
CAT III 600V
TRMS
CAT III 300V
T260D 1000A AC • Jaw size: 60mm• Combination Clamp• Diode• Continuity buzzer
TBM116 1000A AC • Jaw size: 45mm • Auto Check• Diode
• Continuity• Relative zero• Data hold
TBM118 2000A AC • Jaw size: 45mm• Auto Check• Emf detection• Diode
• Continuity• Relative zero• Data hold
1.0
25
Digital Clamp MetersInstruments
Feature Parameter Accuracy
DC Current
AC Current 40, 400, 1000A 2.0% + 5 Digit
DC Voltage 600V 0.5% + 5 Digit
AC Voltage 600V 1.5% + 5 Digit
Resistance 999.9Ω 1.0% + 6 Digit
Temperature -50 to 300°C
Frequency 5 to 500Hz ±0.5% + 4 Digit
Thd%-r 0.0%~99.9%Fundamental 1% + 6 Digit2~3 Harmonics 5% + 6 Digit4~51 St Harmonics 2%
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
Feature Parameter Accuracy
AC Current0.1mA, 6mA60A100A
6mA ±1.0% rdg + 8 Digit60A ±1.0% rdg + 8 Digit100A ±2.0% rdg + 10 Digit
Counts 4 Digits 6000 Counts
Technical Overview
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch, Type-K Thermocouple
Optional Accessories RS232 Cable and Software TBU13X, Adaptor SEE PG 19
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1
Model Specification
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
TRMS
CAT III 300V
TRMS
CAT III 300V
TRMS
CAT III 1000V
Feature Parameter Accuracy
AC Current0.1A, 30A300A3000A
30A ±3 % + 5 Digit300A ±3 % + 5 Digit3000A ±3 % + 5 Digit
Counts 4 Digits 3000 Counts
Technical Overview
TBM135 1000A• Jaw size: 45mm • AC Data Logger
• 5400 Point logging• Continuity
T77N AC• Earth Leakage • Data hold• Low pass filter with high stability 100Hz• Autorange• Bargraph• Auto backlit sensor• Frequency compare function
TF3000 3000A AC• Jaw size: 110mm• Flexible jaw (254mm length)• Sample rate (4 times/second)• Backlit• Data hold
1.0
26
Digital Clamp MetersInstruments
Feature Parameter Accuracy Protection
DC Current 1mA, 10mA, 10A, 100A ±2 % + 10 Digit 150A Rms
AC Current 1mA, 10mA, 10A, 100A ±2 % + 10 Digit 150A Rms
DC Voltage 0.1V, 600V 0.08% + 2 Digit 660Vrms
AC Voltage 0.1V, 600V 2.0% + 3 Digit 660Vrms
Resistance 1. 10kΩ ±1 % + 3 Digit
Technical Overview
Feature Parameter Accuracy
DC Current 0.01, 400A ±2.5% + 5 Digit
AC Current 0.01, 400A ±2.5% + 5 Digit
DC Voltage 400mV, 4, 40, 400, 600V ±1.0% + 4 Digit
AC Voltage 4, 40, 400, 600V 1.5% + 5 Digit
Resistance 400, 4k, 40k, 400k, 4M, 40MΩ4k, 40k, 400kΩ ±0.6%+4 Digit, 4MΩ ±1.0% + 4 Digit, 40MΩ ±2.0% + 4 Digit
Frequency 1kHz to 100kHz ±2.0% + 4 Digit
Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5% + 6 Digit
Counts 3 -3/4 Digits 4000 Counts
Technical Overview
Feature Parameter Accuracy
DC Current 0.01, 400A ±2.5% + 5 Digit
AC Current 40.01, 400A ±2.5% + 5 Digit
DC Voltage 400mV, 4, 40, 400, 600V ±1.0% + 4 Digit
AC Voltage 4, 40, 400, 600V 4, 40, 400V ±1.0% + 4 Digit, 600V ±2.0% + 4 Digit
Resistance 400, 4k, 40k, 400k, 40MΩ4k, 40k, 400kΩ ±0.6%+4 Digit, 4MΩ ±1.0% + 4 Digit, 40MΩ ±2.0% + 4 Digit
Frequency 1kHz to 100kHz ±2.0% + 4 Digit
Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5% + 6 Digit
Counts 3 -3/4 Digits 4000 Counts
Technical Overview
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch
Model Specification
Weight 218g
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Standard Accessories Carry Pouch
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
CAT III 300V
CAT III 600V
TRMS
CAT III 300V
T223 100A AC/DC • Jaw size: 12.5mm• Automotive• Concurrent reading• Resistance • Continuity
TBM061 400A AC/DC• Jaw size: 30mm• Diode• Continuity
• Relative zero• Auto power off
TBM062 400A AC/DC• Jaw size: 30mm• Diode• Continuity
• Relative zero• Auto power off• Backlit
1.0
27
Digital Clamp MetersInstruments
Feature Parameter Accuracy
DC Current 40, 600A
AC Current 40, 600A ±1.8%+ 5 Digit
DC Voltage 400mV, 4, 40, 400, 600V ±1.0%+ 5 Digit
AC Voltage 4, 40, 400, 600V 4, 40, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit
Resistance 600, 6k, 60kΩ4k, 40k, 400kΩ ±0.6% +4 Digit, 4mΩ ±1.0% + 4 Digit, 40mΩ ±2.0% + 4 Digit
Temperature -40°C to 400°C 4mΩ ±1.0% + 4 Digit
Frequency 50Hz to 400Hz 40mΩ ±2.0% + 4 Digit
Capacitance 200µ, 2500µF
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
TBM079 600A AC/DC• Jaw size: 35mm • AmptipTM
• 3-Phase rotation for mains and motors
• Non-contact EF detection• Rotary selector switch• Data hold
T8056 1000A AC/DC • Jaw size: 42mm• Duty cycle• Diode• Continuity
• Auto power off• Relative zero• Data hold
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 1 x 9V Battery
Standard Accessories Carry Case, Temp Probe TBMTEMPPROBE
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
DC Current 400, 1000A ±3.0% + 3 Digit
AC Current 400, 1000A ±3.0% + 3 Digit
DC Voltage 60mV, 600mV, 6, 600, 1000V ±0.8% + 3 Digit
AC Voltage 60mV, 600mV, 6, 600, 1000V ±1.0% + 10 Digit
Resistance 400, 4k, 40k, 400k, 4m, 40MΩ ±2.0% + 3 Digit
Temperature -40°C to 750°C ±1.0% + 6 Digit
Frequency 40, 400, 4k, 40k, 100kHz ±2.0% + 1 Digit
Capacitance 4nF, 40nF, 400nF, 4µ, 40µF ±4.0% + 10 Digit
Counts 3 -3/4 Digits 4000 Counts
Technical Overview
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
AC Current 400, 800A 400A, ±2.0% + 5 Digit, 800A, 5.0% + 30 Digit
DC Current 400, 1000A ±0.5 % + 3 Digit
AC Voltage 600V ±2 % + 5 Digit
DC Voltage 600V ±2 % + 5 Digit
Resistance 400, 4k, 4M, 40MΩ ±1.0 % + 4 Digit
Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5 % + 6 Digit
Frequency 15Hz- 1000Hz
Counts 3 -3/4 Digits 4000 Counts
Technical Overview
TRMS
CAT III 600V
TRMS
AmpTip™
CAT III 600V
CAT III 600V
TBM162 1000A AC/DC• Jaw size: 50mm• Large display• Max hold
• Continuity• Diode• Backlit
1.0
28
Digital Clamp MetersInstruments
Feature Parameter Accuracy
DC Current 100, 200, 500, 1000, 2000A ±2 % + 5 Digit
AC Current 100, 200, 500, 1000, 2000A ±2 % + 5 Digit
DC Voltage 6, 60, 600, 1000V ±1.2 % + 5 Digit
AC Voltage 6, 60, 600, 1000V ±1.2 % + 5 Digit
Resistance 600, 6k, 60k, 6M, 40MΩ ±0.5 % + 5 Digit
Capacitance 60nF, 6µ, 60µ, 600µ, 2000µF ±2.0 % + 5 Digit
Frequency 400Hz
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
Feature Parameter Accuracy
DC Current 400, 2000A ±1.5% rdg + 5 Digit
AC Current 400, 1500A ±1.5% rdg + 5 Digit
DC Voltage 400mV, 4, 40, 400, 1000V ±0.5% rdg + 1 Digit
AC Voltage 400mV, 4, 40, 400, 750V ±1.5% rdg + 4 Digit
Resistance 400, 4k, 40k, 400k, 4M, 40MΩ ±1.0% rdg + 4 Digit
Frequency 10, 1k, 10k, 100k, 400kHz ±0.1% rdg + 4 Digit
Capacitance 4nF, 40nF, 400nF, 4µ, 40µF ±1.0% rdg + 4 Digit
Counts 3 -3/4 Digits 4000 Counts
Technical Overview
Power Source 2 x 1.5V AA Batteries
Standard Accessories Carry Pouch
Optional Temp Probe TBMTEMPPROBE, TBU19X SEE PG 19
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 1 x 9V Battery
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 2 x 1.5V AA Batteries
Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
DC Current 60, 600, 1000A
AC Current 60, 600, 1000A ±1.8%+ 5 Digit
DC Voltage 600, 1000V ±1.0%+ 5 Digit
AC Voltage 600, 1000V 4, 40, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit
Resistance 600, 6k, 60kΩ4k, 40k, 400kΩ ±0.6% +4 Digit, 4mΩ ±1.0% + 4 Digit, 40mΩ ±2.0% + 4 Digit
Temperature -40°C to 400°C ±1.0% + 6 Digit
Frequency 5Hz to 400kHz ±0.5% + 4 Digit
Capacitance 2500µF
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
TRMS
AmpTip™
CAT IV 1000V
TRMS
CAT IV 1000V
TRMS
CAT III 1000V
TBM089 1000A AC/DC• 3-Phase rotation for mains and motors• AmptipTM
• Non-contact EF detection
• Rotary selector switch• Continuity• Flashlight
T2608 2000A DC/ 1500A AC• Jaw size: 57mm• Min/Max• Data hold/Peak hold• Auto power off
• Diode• Continuity• Bargraph
TBM195 2000A AC/DC• Jaw size: 55mm• Dual display• Non-contact EF detection• VFD (Variable frequency drives)
• Relative zero• Data logging• Autocheck• Diode
1.0
29
Digital Clamp MetersInstruments
Feature Parameter Accuracy
DC Current 100, 200, 500, 1000, 2000A ±2 % + 5 Digit
AC Current 100, 200, 500, 1000, 2000A ±2 % + 5 Digit
DC Voltage 6, 60, 600, 1000V ±1.4 % + 7 Digit
AC Voltage 6, 60, 600, 1000V ±1.4 % + 7 Digit
Resistance 600, 6k, 60k, 6M, 40MΩ ±0.5 % + 5 Digit
Frequency 400Hz
Temperature -50°C to 1000°C ±0.3 % + 4 Digit
Capacitance 60nF, 6µ, 60µ, 600µ, 2000µF ±2.0 % + 5 Digit
Counts 3 -5/6 Digits 6000 Counts
Technical Overview
Power Source 2 x 1.5V AA Batteries
Standard Accessories Carry Pouch
Optional Accessories Temp Probe TBMTEMPPROBE, TBU19X SEE PG 19
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 2 x 1.5V AAA Batteries
Standard Accessories Carry Case, Temp Probe TBMTEMPPROBE
Optional Accessories RS232 Cable and Software TBU13X, USB Adaptor SEE PG 19
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
AC Current 40, 400, 1000A 2.2% + 5 Digit
DC Voltage 600V 0.5% + 5 Digit
AC Voltage 600V 1.5% + 5 Digit
Resistance 999.9Ω 1.0% + 6 Digit
Frequency 5 ~ 500Hz 0.5% + 4 Digit
Power0.00 ~ 600kVA, 0.00 ~ 600kW 0.00 ~ 600kVAR
±4.0% + 10 Digit
Thd%-fTotal harmonic distortion
0.0% ~ 999.9%Fundamental 1.5%+6 Digit2~3 Harmonics 7%+6 Digit4~51 Harmonics 2%+6 Digit
Count 3 -5/6 Digits 6000 Counts
Technical Overview
T2000 Earth Resistance Clamp• Jaw size: 32mm • Direct earth probes measurement• Leakage current• Alarm thresholds
• Current noise• Data HOLD function • 99 measurement storage locations
Power Source 4 x 1.5V AAA Batteries
Standard Accessories Resistive Test Loop, Carry Case
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
Resistance
0.01Ω~0.999Ω0.10Ω~0.99Ω1Ω~49.9Ω50.0Ω~99.9Ω100Ω~199.9Ω200Ω~395Ω400Ω~590Ω600Ω~1000Ω
±(1.0%+0.01Ω)±(1.0%+0.01±(1.5%+0.1Ω)±(2.0%+0.3Ω)±(3.0%+1Ω)±(6.0%+5Ω)±(10%+10Ω)±(20%+20Ω)
AC Current
0.00A~80mA80~650mA650~999.5mA1.000~3.995mA4.00~20.00mA
±(2.5%+1mA)±(2.5%+2mA)±(2.5%+0.003A)±(2.5%+0.01A)±(2.5%+0.05A)
Technical Overview
TRMS
CAT III 600V
TRMS
CAT IV 1000V
CAT III 150V
TRMS
TBM197 2000A AC/DC• Jaw size: 55mm• Dual display• Non-contact EF detection
• VFD (Variable frequency drives)• Data logging• Diode
TBM157 1000A AC• Jaw size: 45mm• 3-Phase Power Clamp
• Total power factor• Data logging
1.0
30
Earth Resistance Testers - Selection GuideInstruments
FEATURES T416 T1805 T1105 T1820 T1120 T2000
PAGE 31 31 32 32 32 29
Earth Resistance Test (Ω) 50k 1k 1.2k 2k 2k 1k
Earth Resistance Test (V) 460 30 30 200 200
Micro Processor Controlled •
Long Test • • • • •
Auto Power Off (APO) • •
PC Connection •
Data Saving • •
On Display Help •
Backlight • •
Data Hold • • • •
Test Cables Resistance Compensation
• •
Ground Resisting 4 Wire •
Detection of Disturbances Currents
• •
Taut Band Movement • •
Battery Check • • • • •
Safety Category
*
*Optional accessory software TOPVIEW and USB Cable (T416)
CAT III 265V CAT III 150V CAT III 200V CAT III 150VCAT IV 30V CAT II 300V
1.0
31
Earth Resistance Testers Instruments
Feature Parameter Accuracy
Measuring Ranges
Resistance: 10, 100, 1.000Ω
Earth Voltage 30V AC (5kΩ/V)
Measuring System
Resistance: (Constantcurrent inverter 820Hzapprox, 2mA)Voltage: rectifier type0 - 30 VAC, 40~500 Hz
Withstand Voltage
1.500V AC (one minute) ±1.8% + 4 Digit
Resistance ±2.5% of full scale
Voltage ±1% of full scale
Technical Overview
Power Source 8 x 1.5V AA Batteries
Standard AccessoriesTest Leads (Lengths: Red - 1 Meter and 15 Meters, Yellow - 10 Meters, Green - 5 Meters) Earth Spikes, Shoulder Belt
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 6 x 1.5V AA Batteries
Standard AccessoriesCables and 4 rods, Carry case, English instruction manual, Test Leads (Lengths: Red - 13 Meters, Blue - 20 Meters, Green - 6 Meters, Green - 6 Meters
Optional Accessories Software and USB Cable TOPVIEW
Certificates UL, IEC61010-1. Calibration Certificate ISO9000.Certificate of Conformance
Model Specification
Earth Resistance Measurement
Range Re (Ω) 0.0 - 19.99 20.0 - 199.9 200 - 1999
Resolution (Ω) 0.01 0.1 1
Accuracy ±(2% Reading + 3 digits)
Measuring Frequency
125Hz / 75Hz/41.66Hz ±1Hz
Test Current ≤ 10mA
Open Circuit Voltage
≤ 30V
Wave form of test voltage
Sinusoidal
GROUND RESISTIVITY Measurement
Range p 0.6 - 19.99Ωm
0.125 - 1.256kΩm
1.25 - 19.99kΩm
20.0 - 199.9kΩm
Resolution 0.1Ωm 0.001kΩm 0.01kΩm 0.1kΩm
Accuracy ±(2% Reading + 3 digits)
Measuring Frequency
125Hz / 75Hz / 41.66Hz ±1Hz
Test Current ≤ 10mA
Open Circuit Voltage
≤ 30V
Wave form of test voltage
Sinusoidal
Measurement of DISTURBANCE voltage
Range (V) 500
Resolution (V) 1
Accuracy ±(2% Reading + 3 digits)
Technical Overview
CAT III 265V
CAT III 150V
T416• Earth Resistance Tester• 350 Memory locations• RS232 interface• Resistivity• 2 Wire earth resistance measurements
(2 WIRES)• Three wire earth resistance
measurements (3 WIRES)
• Calculation of earth resistance average value with both two and three wires (RAVG)
• Calculation of resistivity average value (ρAVG)
• 4 Wire method
T1805 • Analogue Earth Resistance Tester• Large display • Taut band movement• 2 and 3 Wire tester
1.0
32
Earth Resistance TestersInstruments
Feature Parameter Accuracy
Measuring Ranges
Resistance: 0-12Ω, 0-120Ω, 0-1200Ω
Earth Voltage 30V AC (5kΩ/V)
Measuring System
Earth resistance by Constant current inverter Hz approx, 2mA square signal
Resistance ±3% of full scale
Voltage ±2.5% of full scale
Technical Overview
Power Source 8 x 1.5V AA Batteries
Standard AccessoriesTest Leads (Lengths: Red - Meter and 15 Meters, Yellow - 10 Meters, Green - 5 Meters) Earth Spikes, Shoulder Belt
Model Specification
Feature Parameter Accuracy
Measuring Ranges
Resistance: 20, 200, 2kΩ
Earth Voltage 200V AC (40 - 500hz)
Measuring System
Earth resistance by constant current inverter, 820Hz, 2mA Approx
Over voltage indication
1 (MSD)
Resistance ±2% rdg + 2 Digit
Voltage ±1% rdg + 2 Digit
Counts 3 -1/2 Digits 2000 Counts
Technical Overview
Power Source 8 x 1.5V AA Batteries
Standard AccessoriesTest Leads (Lengths: Red - Meter and 15 Meters, Yellow - 10 Meters, Green - 5 Meters) Earth Spikes, Shoulder Belt
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
Measuring Ranges
Resistance: 20Ω, 200Ω, 2kΩ
Earth Voltage 0-200V AC
Measuring System
Earth resistance by Constant current inverter 820Hz approx, 2mA square signal
Withstand Voltage
1.500V AC (one minute)
Resistance ±2.0 % + 2 Digit
Voltage ±1.0 % + 2 Digit
Technical Overview
Power Source 8 x 1.5V AA Batteries
Standard AccessoriesTest Leads (Lengths: Red - Meter and 15 Meters, Yellow - 10 Meters, Green - 5 Meters) Earth Spikes, Shoulder Belt
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
CAT III 300V
CAT II 300V
CAT IV 300V
T1105 • Earth Resistance Tester• Analogue display• Safety voltage protection• Compact design
T1820• Digital Earth Resistance Tester• Earth voltage detection
• 2mA earth resistance to test • 2 and 3 Wire Testing
T1120• Digital Earth Resistance Tester• Safety voltage protection
• Compact design
1.0
33
Compliance TestersInstruments
Code Instrument Page Number
TCTCS Case
TCTCDTFM Foam
T1151 1000V Digital Insulation Tester 37
T1120 Digital Tester 32
TEL1TLB ELCB /Polarity Socket Tester 44
T1125 LOOP/PSC Tester 41
TBM3030 Digital Clamp Meter 22
T890 Phase Rotation Tester 45
Code Instrument Page Number
TCTCS Case
TCTCDKFM Foam
T1800 Insulation Tester 36
T1805 Analogue Earth Resistance Tester 31
TEL1TLB ELCB /Polarity Socket Tester 44
T1825 Loop/PSC Tester 41
TBM811 Digital Multimeter 16
T860 Phase Rotation and Motor Rotation 46
Code Instrument Page Number
TCTCS Case
TCTDTFM Foam
T1851 Digital Insulation Tester 37
T1820 Digital Earth Resistance Tester 32
TEL1TLB ELCB /Polarity Socket Tester 44
T1825 LOOP/PSC Tester 41
TBM3030 Digital Clamp Meter 22
T887 LCD Phase Rotation 46
TCTCDK Compact Digital Compliance Kit • Kit supplied in a sturdy case with foam cut out to secure each instrument• Refer to individual products for technical overview
TCTDT Digital Compliance Kit• Kit supplied in a sturdy case with foam cut out to secure each instrument• Refer to individual products for technical overview
TCTRP Analogue Compliance Kit• Kit supplied in a sturdy case with foam cut out to secure each instrument• Refer to individual products for technical overview
FEATURES T1132 T1800 T1832 T1851 T1151 T10020C T5050 TIN4D TIN5D TIN6D TIN6A TIN7D TIN8D
PAGE 36 36 36 37 37 38
Insulation Tester Voltage (V) 1000 1000 1000 1000 1000 1000 5kv 5kv 10kv 10kv 10kv 10kv
Insulation Resistance Ranges (Ω)
250V/100M
500V/200M
1000/400M
250V/100M
500V/200M
1000/400M
250V/100M
500V/200M
1000/400M
250V/200M
500V/200M
1000/200M
250V/2G
500V/4G
1000/200M
500
50M
500V/
50M
500V/25GΩ
1kV/500GΩ
2.5k/125Ω,
5k/250Ω
1kV/50G
2.5k/125Ω,
5k/250Ω
10kV/250Ω
500V/25GΩ
10kV/500Ω
1000/200MΩ
5kV/200GΩ
10kV/400Ω
800kΩ
500GΩ
500V/700GΩ
15kV/2TΩ
Micro Processor Controlled • • • • • • •
Bargraph • • • • • •
Counting Timer • • • • •
Long Test • • • • • • •
Auto Range • • • • • • •
Auto Power Off (APO) • • • • • •
Auto Discharge • • • • • • • • • • • •
External Voltage Warning Indication • • • • • • •
Live Circuit Warning • • • • • • • • •
PI Polarisation Index • • • • • •
Eeprom Calibration • • • • •
Backlight • •
Data Hold •
Relative
Auto Null •
Fuse Protection • • • • • • • • • •
B.S. 16TH Edition • • • •
Mirror Scale • •
Taut Band Movement • • • •
AC Measurement (V) 500 500 500 500 700 500 500
DC Measurement (V) 950 500 500
Hand Free Testing Locker • • •
Battery Check • • • • • • • • •
Continuity Test Range (Ω) 3/500 50 3/500 200/ 2000 1999 5k 5kΩ
DAR (Dialectical Absorption Ratio) • • •
Lifetime Warranty • • •
Safety CategoryCAT III (V)
300V
CAT III (V) 300V
CAT III (V) 300V
CAT III (V) 300V
1.0
34
Insulation Testers - Selection GuideInstruments
CAT III 500V CAT III 500V CAT III 500V CAT III 500V CAT III 600V
FEATURES T1132 T1800 T1832 T1851 T1151 T10020 T5050C TIN4D TIN5D TIN6D TIN6A TIN7D TIN8D
38 38 39 39 39 40 40
Insulation Tester Voltage 1000V 1000V 1000V 1000V 1000V 1000V 5kv 5kv 10kv 10kv 10kv 10kv 15k
Insulation Resistance Ranges
250V/100MΩ
500V/200MΩ
1000/400MΩ
250V/100MΩ
500V/200MΩ
1000/400MΩ
250V/100MΩ
500V/200MΩ
1000/400MΩ
250V/200MΩ
500V/200MΩ
1000/200MΩ
250V/2GΩ
500V/4GΩ
1000/200MΩ
500V/
50M
500V/
50M
500V/25G
1kV/500G
2.5k/125Ω, 5k/250
1kV/50G
2.5k/125,
5k/250
10kV/250
500V/25G
10kV/500
1000/200M
5kV/200G
10kV/400
800k
500G
500V/700G
15kV/2T
Micro Processor Controlled • • • • • • •
Bargraph • • • • • •
Counting Timer • • • • •
Long Test • • • • • • •
Auto Range • • • • • • •
Auto Power Off • • • • • •
Auto Discharge • • • • • • • • • • • •
External Voltage Warning Indication • • • • • • •
Live Circuit Warning • • • • • • • • •
PI Polarisation Index • •
Eeprom Calibration • • • • •
Backlight •
Data Hold •
Relative
Auto Null •
Fuse Protection • • • • • • • • • •
B.S. 16TH Tdition • • • •
Mirror Scale • •
Taut Band Movement • • • •
AC V Measurement (V) 500 500 500 500 700 500 500
DC V Measurement 950 500 500
Hand Free Testing Locker • • •
Battery Check • • • • • • • • •
Continuity Test Range (Ω) 3/500 50 3/500 200Ω/ 2000Ω 1999 5kΩ 5k
DAR (Dialectical Absorption Ratio) • • •
MOV (Metal Oxide Varistor)
Safety CategoryCAT III (V)
500V
CAT III (V) 500V
CAT III (V) 500V
CAT III (V) 500V
CAT III (V) 600V
1.0
35
Insulation Testers - Selection GuideInstruments
CAT III 300V CAT III 300V CAT III 300V CAT III 300V CAT III 300V CAT IV 600V
1.0
36
Insulation TestersInstruments
Feature Parameter Accuracy
Test Voltages and measuring range
250V 0-100MΩ, 500V 0-200MΩ, 1000V 0-400MΩ
Voltage ±2% of scale length
Short circuit terminal current 145mA DC Approx Insulation ±5% of Indicated value
Output Voltage on open circuit Rated test voltage + 10%
Short Circuit Current (Max) 2mA DC
Continuity Range 0 -50Ω
Open circuit terminal voltage 445mV DC Approx
Voltage Measurement 0 -500 VAC
Technical Overview
Power Source 8 x 1.5V AA Batteries
Standard AccessoriesTest Leads (Lengths: Red - Meter and 15 Meters, Yellow - 10 Meters, Green - 5 Meters) Earth Spikes, Shoulder Belt
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source 8 x 1.5V AA Batteries
Certificates Certificate of Conformance
Model Specification
Technical Overview
Insulation Test Voltage 250, 500, 1000V
Insulation Resistance 250V (100MΩ), 500V (200MΩ), 1000V (400MΩ)
AC Voltage 0 to 600V
Ohm meter 3 to 500Ω
Feature Parameter Accuracy
Test Voltages and measuring range
250V 0-100MΩ, 500V 0-200MΩ, 1000V 0-400MΩ
Voltage ±3% of scale lengt
Short circuit terminal current 210mA DC Approx Insulation ±5% of Indicated value
Output Voltage on open circuit Rated test voltage + 10%
Short Circuit Current (Max) 1.3mA
Continuity Range 0 -50Ω
Open circuit terminal voltage 445mV DC Approx
Voltage Measurement 0 -500 VAC
Technical Overview
Power Source 8 x 1.5V AA Batteries
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
LIFETIME WARRANTY
CAT III 500V
LIFETIME WARRANTY
CAT III 500V
CAT III 500V
T1132 1000V • Analogue Insulation Tester• Safety voltmeter protection• Live circuit indication• Auto discharge• AC voltage measurement• Zero adjustment knob
T1800 1000V• Analogue Insulation Tester• Heavy duty carry case• Taut band movement• Auto discharge
• Colour coded scale• Live circuit indication• AC Voltage measurement
T1832 1000V• Analogue Insulation Tester • Taut band movement• Live circuit indication• 200mA continuity short circuit current• Auto discharge
• AC voltage measurement• Rugged construction• Nulling of test leads • Continuity buzzer• Mirror scale
1.0
37
Insulation TestersInstruments
Feature Parameter Accuracy
Test Voltages and measuring range
250V 0-200MΩ, 500V 0-200MΩ, 1000V 0-2000MΩ
Voltage ±1.5 % + 3 Digit
Short circuit terminal current 210mA DC Approx Insulation ±1.5 % + 5 Digit
Output Voltage on open circuit Rated test voltage + 10%
Short Circuit Current (Max) 1mA
Continuity Range 0-2kΩ
Open circuit terminal voltage 445mV DC Approx
Voltage Measurement 0 -500 VAC
Counts 3 -1/2 Digits 2000 Counts
Technical Overview
Power Source 8 x 1.5V AA Batteries
Certificates UL, , IEC61010-1. Certificate of Conformance
Model Specification
Power Source 8 x 1.5V AA Batteries
Certificates Certificate of Conformance
Model Specification
Technical Overview
Insulation Test Voltage 250,500,1000V
Insulation Resistance 250V (2k-2GΩ), 500V (4k-4GΩ), 1000V (8k-8GΩ)
AC Voltage 0 to 700V
Ohm meter 0.01 to 1999Ω
Test Current >SH220mA
T1151 1000V and T11510LED Insulation Testers
• Digital Insulation Tester• Safety voltmeter protection• Live circuit indication• Auto discharge• AC voltage measurement• OLED Display (Organic light-emitting diode - T11510LED)
T1151 1000V and T11510LED
CAT III 500V
CAT III 500V
LIFETIME WARRANTY
LIFETIME WARRANTY
T1851 1000V• Digital Insulation Tester• Continuity buzzer • Live circuit warning• 210mA continuity short circuit current
• AC voltage measurement• Auto power off• Auto discharge• Live circuit indication
T1151
T115150LED
1.0
38
Insulation TestersInstruments
Power Source Mechanical winder
Standard Accessories Case, Leads
Model Specification
Technical Overview
Test Voltage 1000V
Insulation Resistance 5000MΩ
Power Source Mechanical winder
Standard Accessories Case, leads
Model Specification
Technical Overview
Rated Voltage 1000V
Insulated Resistance 200MΩ
Continuity Range 0 - 50kΩ
Accuracy±5 % Over First Effective Range±10 % Over 2nd Effective Range
Power Source 8 x 1.5V C Batteries Alkaline
Standard Accessories Carry Pouch
Certificates Certificate of Conformance
Model Specification
Insulation Test Voltage 500V 1000V 2500V 5000V
Insulation Resistance 0-30GΩ 0-60GΩ 0-125GΩ 0-250GΩ
Accuracy ±3% reading + 2 digit
Output Current Limit 50µA to 100µA
Live Warning >500 Volts
Operating Temperature 0 to 40°C
Operating Humidity 85% Max relative humidity
Technical Overview
T10020C 1000• Hand Crank• Sturdy movement suitable for stringent fieldwork• Built-in discharge facility for operator safety• Accurate and stable reading using knife-edge pointer• Improved AC brushless generator• Dust protected terminals
T5050C 500V• Hand Crank• Cross coil movement suitable for stringent fieldwork• Built-in discharge facility for operator safety• Accurate and stable reading using knife-edge pointer• Improved AC brushless generator• Guard terminal to minimise effect of surface leakage current
TIN4D 5KV• Displays insulation test time• Displays warning• Fully protected crow bar• Insulation test time interval up to 99 sec• Auro range• 4 Insulation test voltage
1.0
39
Insulation TestersInstruments
Power Source 8 x 1.5V C Batteries Alkaline
Standard Accessories Carry Pouch
Certificates EN61010-1. Certificate of Conformance
Model Specification
Insulation Test Voltage 1000V 2500V 5000V 10000V
Insulation Resistance 0-60GΩ 0-125GΩ 0-250GΩ 0-500GΩ
Accuracy ±3% reading + 2 digit
Output Current Limit 50µA to 100µA
Live Warning >500 Volts
Operating Temperature 0ºC to 40ºC
Operating Humidity 85
Technical Overview
Power Source 6 x 1.5V C Batteries
Certificates Certificate of Conformance
Model Specification
Feature Parameter Accuracy
Insulation Test Voltage 5kV 10kV
Insulation Resistance 0-200GΩ 0-400GΩ
Accuracy ±5% of scale length
Output Power Limit 50µA to 100µA
Live Warning >500 V AC
Operating Temperature 0ºC to 40ºC
Operating Humidity 85
Technical Overview
Power Source 8 x 1.5V C Batteries Alkaline
Standard Accessories Carry Pouch
Certificates EN61010-1. Certificate of Conformance
Model Specification
Feature Parameter
Insulation Test Voltage 500V - 10kV
Measuring Range (Autoranging)500V - 10kV,25GΩ - 500GΩ
Output Power Limit 1W
Short Circuit Current (Max) 1.25mA
Insulation Accuracy ±3% + 1 Digit
Technical Overview
CAT III 300V
TIN5D 10kV• Auto ranging on all ranges• Displays insulation test time• Displays warning• Fully protected crow bar• Insulation test time interval up to 99 sec• 4 Insulation test voltage
TIN6D 10kV• 20 Insulation test voltages
(500V - 10kV)• Heavy duty carry case• Silicone test leads• Anti skid/vibration absorbing enclosure• Live circuit warning
• Auto discharge• Insulation test time interval
up to 99 sec• Auto range• Auto off
TIN6A 5kV-10kV• Live circuit warning• Auto discharge• Battery life indication • Heavy duty carry case• Silicon test leads• 2 Test voltage: 5kV and 10kV
1.0
40
Insulation TestersInstruments
TIN7D 10kV and TIN7DOLED 10kV
TIN7D
TIN7DOLED
Power Source 8 x 1.5V C Batteries Alkaline
Certificates EN61010-1, EN61326-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
Insulation Test Voltage500V, 10kV (20 x 500V increments)
±5% + 1 Digit
Measuring Range 0-250GΩ, 800kΩ to 500gΩ
Output Power Limit 1W
Short Circuit Current (Max) 1.25mA
Dielectric Absorption Ratio Yes R @ 1 min
Polarisation Index Yes R @ 1 min
Technical Overview
TIN7D 10kV and TIN7DOLED 10kV Insulation Testers• Polarisation index*• Dielectric absorption ratio*• Live circuit warning• Auto discharge• Insulation test time interval up to 10 mins• 20 Insulation test voltage• Auto range• OLED Display (Organic light-emitting diode - TIN7DOLED)
CAT III 300V
CAT III 300V
Power Source Rechargeable Battery with AC charge
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
Insulation Test Voltage500V, 15kV (500V increments)
±5% + 5 Digit
Measuring Range70GΩ/0.5kV 70GΩ at 0.5kV - 2TΩ at 15kV
Short Circuit Current (Max) Up to 5mA
Dielectric Absorption Ratio Yes
Polarisation Index Yes
Technical Overview
CAT IV 600V
TIN8D 15kV• Insulation test voltage up to 15kV• Test insulation resistance up to 2 TΩ
(2000GΩ)• Short circuit current up to 5mA• Auto hold function to freeze
the reading• Overload protection• 30 insulation test voltages
• Adjustment for testing time (duration) : 1~30 minutes
• Software included• USB to RS-232 data transmission.• 200 Measurement results can be
saved and recalled on the display
* Polarisation and dielectric ratio are useful to schedule maintenance. The user can keep record of the PI and DAR results and analyse these over time. Maintenance can be done according to analysis and down time can be scheduled thus saving production time.
1.0
41
PSC Loop TestersInstruments
Power Source 8 x 1.5V AA Batteries
Standard Accessories Carry Case, Strap, Leads
Certificates UL, IEC61010-1. Certificate of Conformance IEC61326-1
Model Specification
Feature Parameter Accuracy
Measuring :Loop :PSC
0 ~ 2000Ω0 ~ 6kA @ 230V AC
± 5% ± 2 Digit
± 12% + 5 Digit
Operating Voltage (VAC) 230V ± 20V 50Hz ± 2%
TEST CURRENT - Loop/PSC/Load 11.76A
Neutral Wire Resistance 0.01 - 2000Ω
Live Wire Resistance 0.01 - 2000Ω
PSC Current (L-N) Max 6kA @ 230V AC
PSC Current (L-E) Max 6kA @ 230V AC
Operating Temperature -10˚C to 40˚C
Humidity 80% Max Relative humidity
Technical Overview
CAT III 300V
LIFETIME WARRANTY
Power Source 8 x 1.5V AA Batteries
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Measuring :Loop :PSC
0 ~ 2000Ω0 ~ 6ka @230v (L-n)
Operating Voltage (VAC) 50 ~275V AC 50 or 60Hz
TEST CURRENT - Loop/PSC/Load 12A (Load Voltage shown as @ 16A
Resolution (ohm) 0.01 (Loop)
Thermal Protection Electronic
Accuracy Voltages ±1% (210 ~ 250V)
Accuracy Loop ±2% (0.05 ~ 50Ω), ±3% (500Ω), ±15% (above 500Ω)
Operating Temperature 0 to 40˚C
Humidity 85%
Technical Overview
CAT III 300V
T1826 - PSC Loop Tester• Fault finding• Electrical network analyser• Earth resistance without peg
• Analyse to SANS 10142• Loop test for L-E, L-N and PSC
T1125• Load/No load tester• PSC (Prospective short circuit current)• Safety voltmeter protection• Micro processor controlled
• Test up to 100A (6kA) circuit breakers• Each phase tested separately on
a 3-Phase system• Designed to SANS 10142
Power Source 8 x 1.5V AA Batteries
Standard Accessories Carry Case, Strap, Leads
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Feature Parameter Accuracy
Measuring :Loop :PSC
0 ~ 2000Ω0 ~ 6kA @230V (L-n)
±2% (0.05 ~ 50Ω), ±3% (500Ω), ±15% (above 500Ω)
±12% + 5 Digit
Operating Voltage (VAC) 50 ~275V AC 50 or 60Hz 6KA @ 230V AC
TEST CURRENT - Loop/PSC/Load
12A (Load Voltage shown as @ 16A)
Resolution (ohm) 0.01 (Loop)
Thermal Protection Electronic
PSC Current 600kA @ 230V AC
(L-N) Max ±2% (0.05 ~ 50Ω), ±3% (500Ω), ±15% (above 500Ω)
Operating Temperature -10 to 40˚C
Humidity 85% Max relative humidity
Technical Overview
LIFETIME WARRANTY
CAT III 300V
T1825 - PSC Loop Tester• Load/No load tester• Prospective short circuit current• Volt drop test• Micro processor controlled
• Test up to 100A (6kA) circuit breakers• 3-Phase system test• Designed to SANS 10142
1.0
42
Loop, ELCB and Polarity TestersInstruments
Instruments listed below are to be used in conjunction with the TIMP57 in order to do high line loop tests up to 400kA
Power Source 8 x 1.5V C Batteries
Standard Accessories 2 Test Cables (3m length, with Alligator Clips), RS-232 Serial Cable, Carrying Bag
Certificates ISO9000 Calibration Certificate, Certificate of Conformance
Model Specification
Type of measurement P-N, P-P, P-PE Loop/Line impedance and short circuit current calculation
Resolution of ohms 0.1mΩ(Zloop) ; 1A (Ipsc)
Test current approx: 200A
Frequency range 50Hz ±5%
Short Circuit Current (Max) 1.25mA
Dielectric Absorption Ratio R @ 1 min
Polarisation Index R @ 10 min
Technical Overview
Power Source No batteries requiRed
Certificates Certificate of Conformance
Model Specification
Feature Parameter Accuracy
Operating Voltage 550 550Vac @ ±15%
ELCB current 10mA - 50mA30A ±3 % + 5 Digit 0.01A
Frequency of Operation 50/60Hz
Voltage (L-E) 1% (1mA)
Meter ±1% of full scale
Operator Temperature -5˚C to 45˚C
Fuse Protected 0.1A Fast Blow
Technical Overview
Power Source 8 x 1.5V AA Batteries Alkaline
Certificates Certificate of Conformance EN 0081-1. EN 50082-1
Model Specification
Feature Parameter Accuracy
Rated tripping current 0 to 1000mA ± 1mA
Resolution 1mA
Operating Voltage (L-E) 100 to 450V AC 50 - 50V AC 2% ± 1V 350 - 450V AC
Maximum Trip Time 100 secs (1mS resolution) 1mS ± 1mS 5% ± 1V
Operating Temperature -50ºC to 40ºC
Operating Humidity 80%
Phase Angle Setting 0 and 180º selectable
Technical Overview
LIFETIME WARRANTY
CAT III 450V
TIMP57Accessory for measuring and recording the efficiency of single-phase and 3-Phase multi-string systems
• Line Loop Adaptor• Test up to 400kA
TEL2SC• ELCB Tester/Polarity• Taut band movement• Wiring check• Robust• Two and three wire operation• Designed to SANS 10142
TEL28• Industrial ELCB• Micro-processor• Direct read out of time/current• Voltage measurement • Suitable for industrial, mining and
domestic environments
• Each phase tested separately on a 3-Phase system industrial, mining and domestic environments
• Designed to SANS 10142
MACROG3 T419 T60
1.0
43
ELCB and Polarity TestersInstruments
Feature Range Accuracy
Resistance Ranges
0 to 200Ω in steps of 100µΩ0 to 2000mΩ in steps of 1Ω0 to 20Ω in steps of 10Ω0 to 200Ω in steps of 100mΩ
±0.5% of reading ±2 digits
Test Current1mA = 2000Ω range 10mA = 200Ω range 100mA = 2000mΩ range
Maximum Output Voltage 380/550 volts
Test Current Accuracy ±0.1%
Technical Overview
Power Source 12V DC battery poweRed, 8 x 1.5V C Batteries Alkaline
Standard Accessories Test Leads, Shoulder Belt
Certificates Certificate of Conformance
Model Specification
Feature Parameter Accuracy
Rated Tripping Current 0-1000mA at 317 Volts ±1% reading ±2 digits
Lowest Resolution 1mA to 10ms
Operating Voltage 380, 550V 1% reading ±1 digit
Maximum Trip Time 99.99 secs
Operating Temperature 0ºC to 40ºC
Operating Humidity 80%
Technical Overview
Power Source 6 x 1.5V C Batteries Alkaline
Certificates Certificate of Conformance
Model Specification
LIFETIME WARRANTY
Power Source 8 x 1.5V AA Batteries Alkaline
Certificates Certificate of Conformance EN 61326-1
Model Specification
Feature Parameter Accuracy
Rated Tripping Current 3mA - 500mA 5% ± 1mA
Operating Voltage (L-E) 20V AC to 280V AC 2% ± 1V AC
Maximum Trip Time 3secs (1mS resolution) 2% ± 2mS
Operating Temperature -5ºC to 45ºC
Operating Humidity 80%
Phase Angle Setting 0º or 180º
Technical Overview
LIFETIME WARRANTY
CAT III 240V
T1812• Automatic data hold function• Zero crossing testing at 0º or 180º• Disconnection phase polarity• Polarity trip indicator (positive or
negative phase)
• Wiring polarity indicator• Measures voltage and frequency
between line and earth before testing
T4137• Digital Milliohm Meter• Four terminal measurement • Large LCD display• Robust lightweight case with
O-ring seal
• Bonding tests• Earth continuity testing• Designed to SANS 10142
TELE10L• Industrial ELCB• Micro processor• Fully programmable (Direct readout - time or current)• Voltage measured during test
1.0
44
ELCB and Polarity TestersInstruments
Feature Parameter
Current Settings 999mAac/50Hz
Phase-start-selection 0°C and 180°C
Operating Voltage (L-E) 60Vac to 317Vac (525V System)
Timer Resolution 1mS (Max Time = 99.99s)
Current Resolution 1mA
Voltmeter Resolution 1V
Earth Leakage Constant Current IAC 5 to 999 (mA) @50Hz
Ramping Current 5 to 999 (mA)
Sensitivity Disconnection Check 5 to 999 (mA)
Time Delay Disconnection Check(s) 0.001 - 99.999
Maximum Current Consumption 10mA
ELCB Voltage Measurement (L-E) (V AC) 10 to 330V
ELCB Tester Voltage Present (VELCB) LED
ELCB Fuse (Slow Blow) 1.5A
Technical Overview
Power Source 8 x 1.5V C Batteries Alkaline
Standard Accessories Test Leads x 2 (terminate own plug)
Certificates Certificate of Conformance
Model Specification
TEL11 ELCB/Phase Rotation Tester and TEL11OLED ELCB/Phase Rotation Tester
• 3-Phase presence• 3-Phase rotation• TEST for disconnection sensitivity• TEST for disconnection time• Select one of 3-Phase to test ELCB• Measure voltage phase to Earth• Over temperature protection• Phase polarity trip indicator
TEL11 and TEL11OLED
TEL11
TEL11OLED LIFETIME WARRANTY
LIFETIME WARRANTY
Rated Tripping Current 10, 15, 20, 25, 30, 35mA
Resolution 5mA
Operation Voltage 220V
Technical Overview
TEL1TLB• Socket• ELCB Tester/Polarity• Live on earth indication (LCD Display)• Identifies 6 wiring conditions• Earth tripping function• Floating earth detection• Ready-board compatible• LCD displays a floating earth when wiring is incorrect and brass knob is touched • Designed to SANS 10142
1.0
45
ELCB and Phase Rotation TestersInstruments
Standard Accessories Carry Pouch
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Operating Voltage 150 to 1000VAC
Operating Frequency 45 to 65Hz
Circuit Structure Electronic
Operating Temperature -10ºC to 50ºC
Humidity 80%
Power Source 4 x 1.5 AA Batteries
Current Consumption 15mA
Cable Length Approx 800mm
Technical Overview
CAT III 1000V
0-10kΩ
Pote
ntio
met
er to
te
st a
udio
& v
isua
l
Blue OFF RedPhase selection switch
Voltage output pointsfor multimeter
V+
V+
Earth
Line 1 Blue
Line 2Red
Earth Reference
Line 2 Red
Line 1Blue
Plug conFiguration
±115V
±230V
±115V
http://www.hellermanntyton.co.za/downloads.html
Application video
Standard Accessories Carry Pouch
Certificates Certificate of Conformance
Model Specification
Operating Voltage 90 - 600 VAC
Operating Frequency 50/60 Hz
Operating Temperature -10ºC to 40ºC at 80%
Humidity Max relative humidity
Cable Length 1.1m each of Red (R), White (S) and Blue (T)
Technical Overview
TIMT• Line Insulation Monitor Tester• Testing of IT supply systems from high impedance transformers• Test between earth reference and phase with output connections for a multimeter• Test Insulation monitoring alarm by adjusting the potentiometer to verify the audio
and visual indication
T890• 3-Phase Detector (Non-contact)• Clamps over wire insulation without contact on conductor• Non-contact sensor clips• Open phase and phase sequence• Magnets on back of unit to mount on metal surfaces
T855• 3-Phase Rotation Indicator• Fused test leads• Rotating disc• Colour coded Red/white/Blue• Large alligator clips• Real motor behaviour
1.0
46
Phase Rotation TestersInstruments
Standard Accessories Carry Pouch
Certificates Certificate of Conformance
Model Specification
Operating Voltage 100 to 600VAC
Operating Frequency 45 to 75Hz
Circuit Structure Electronic
Operating Temperature 0ºC to 50ºC at 90º
Humidity Max relative Humidity
Power Consumption (Correct)
±14mA for motor rotation field test±7mA for Phase rotation field indication
Technical Overview
LIFETIME WARRANTY
Standard Accessories Carry Pouch
Certificates Certificate of Conformance
Model Specification
Operating Voltage 40 - 700 VAC
Operating Frequency 50/60 Hz
Operating Temperature -1ºC to 55ºC
Humidity Not in full sunlight
Cable Length 60cm each of Red( R), White (S) and Blue (T)
Technical Overview
LIFETIME WARRANTY
T860• 3-Phase and Motor Rotation Indicator• Test rotation of unconnected motors• Heavy duty alligator clips • Open phase identification• Phase presence• Colour coded: Red/White/ Blue
T887• 3-Phase Rotation LCD Indicator• Phase rotation and phase presence• Colour coded Red/White/Blue• Large alligator clips
1.0
47
Miscellaneous, Voltage and Phase Rotation TestersInstruments
Operating Voltage 1000V to 1000V
Frequency 50/60 Hz
Certificate IEC/EN61010-1
Technical Overview
http://www.hellermanntyton.co.za/downloads.html
Application videoIncorrect phase sequence
Correct phase sequence
Power Source 4 x 1.5V LR44 Batteries
Model Specification
Technical Overview
Voltage Detection 5V ~1000V AC
Current Sensitivity >100mA
Frequency Range 50 to 500Hz
Operating Temperature -10°C to 50°C
Operating Humidity <80 %RH
CAT IV 1000V
Power Source TX: 1 x 9V Battery, RX: Mains
Certificates Certificate of Conformance
Model Specification
Operating Voltage 200 - 250 V AC
Frequency 47 - 63Hz
Duty Cycle 10µs
Transmitter Power Wall Socket
Receiver Power 1 x 9V Battery
Technical Overview
T70• Phase Sequence Indicator and Voltage Detector• Detection AC voltage• Phase sequence and conformity test with 1 wire method• With or without contact measurements• LED Red and buzzer indication• Practical pen clip• Clamp voltage detectors together
T475• Volt/Current Tracer• Detect current through shielded/armoured cable• Adjustable sensitivity• Non-contact• Visual and Audio
T534 • Circuit Breaker Identifier• Tracing plug sockets to circuit breakers• Battery check• Signal strength buzzer• Calibrate funtion by moving receiver across circuit breakers• Wiring indications
1.0
48
Voltage Testers and Surge ProtectionInstruments
Power Source Probe: 1 x 9V Battery, Tone: 1 x 9V Battery
Standard Accessories Carry Pouch
Certificate Certificate of Conformance
Model Specification
Tone Generator
Waveform Square Ware
Frequency ±1.13kHz
Amplitude 9V P-P
Over voltage Protection ±100V
Amplifier Probe
Frequency Detection 1-12kHz
Receiver distance 50-60cm
Sensitivity Control √
Technical Overview
100mm 65mm
Operating Voltage 120 - 250 V AC
Technical Overview
Code Size
T45200 100mm
T45000 65mm
TSP1A Surge Plug Top (Green)
TSP1AF Surge Plug Top (Red)
Flat PinRated Voltage 230V/50Hz
Max Continuous Operating Voltage
275V AC
Max Continuous Current 16A
Max Surge Current 8kA
Fusing Integrated 104ºC Thermal and 16A over current fuse
Temperature Range -10°C to 70°C
Technical Overview
Certificates SANS 164-0 Approval
Standards Compliance IEC 61643-1
Model Specification
T180 Tone and Probe Kit• With tone generator and amplifier probe• Sensitivity control• Alligator clips and RJ11 connector• Single or dual alternating tone• Use on de-energised circuits
Surge Plugs• High surge handling capability• Incorrect power socket wiring detection• Economical secondary protection• Thermal and over-current fusing• Visual fault indication• Differential and common mode protection• 2 Year warranty
T45200/T45000• Neon Screwdrivers
1.0
49
Voltage TestersInstruments
Operating Voltage 50V - 1000V AC
Frequency 50 - 500Hz
Technical Overview
Power Source 2 x AAA 1.5V Batteries
Certificates EN:61010-1, EN:61326-1
Model Specification
CAT III 600V
Operating Voltage 5V - 1000V AC
Frequency 50 - 500Hz
Technical Overview
Power Source 1 x AAA 1.5V Battery
Certificates CE EN:61010-1, EN:61326-1
Model Specification
CAT IV 1000V
Power Source 4 x 1.5V LR44 Batteries T515BATT
Model Specification
Operating Voltage 70 - 600V AC
Technical Overview
TS500 • Non-contact voltage detection• Audio/visual/vibration indication• Polarity check• Microwave leakage
TLVD15• Non-contact voltage detection• LED and tone indication• Flashlight
TLVD17• Non-contact voltage detection• Sensitivity adjustable • LED and tone indication• Identifies live and neutral
1.0
50
Voltage TestersInstruments
Power Source No Batteries
Certificates IP65, IEC61243-3, DIN/VDE 0682-401
Model Specification
Power Source No Batteries
Certificates IEC61010-1
Model Specification
Operating Voltage 110 - 750V AC/DC
Technical Overview
Voltage Range 110V, 230V, 380V, 690V, 1000V AC/DC
Technical Overview
Voltage Range 6V,12V, 24V, 50V, 120V, 230V, 400V, 690V, 1000V
Transient protection 8kV
Technical Overview
Power Source No Batteries
Optional Accessories Wibreneon (spare neon optional)
Model Specification
CAT IV 1000V
CAT III 1000V
WIBRETEST• Industrial Heavy Duty• AC/DC• Neon Indication (Green, Red)• Polarity• Oil resistant
WIBRE1000• Dust and waterproof• AC/DC• IP65• LED indicators• Polarity• Oil resistant
TBT69• Industrial• Polarity LED indicators• Electric field detection• LCD display• RCD (ELCB) tripping (30mA)• Continuity• Attached red probe with screw-on 4mm test tip
CAT IV 300V
1.0
51
Voltage TestersInstruments
Operating Voltage ACV 12 ~ 1000V, DCV 12 ~ 1000V
Technical Overview
Power Source No Batteries
Certificates IP65, 61243-3:2011-02
Model Specification
Operating Voltage ACV 12 ~ 1000V, DCV 12 ~ 1000V
Technical Overview
Power Source 2 x 1.5V AAA Batteries
Certificates IP65, 61243-3:2011-02
Model Specification
Operating Voltage 6V, 12V, 50V, 110V, 230V, 415V AC/DC
Technical Overview
Power Source 2 x 1.5V AAA Batteries
Certificates IP66, IEC61010-1 , 61243-3:2011-02
Model Specification
CAT III 1000V
CAT III 1000V
CAT III 600V
DUSPOLA• Analogue Plus• Dust and waterproof• Vibration• Phase sequence• LED indicators• Solenoid movement• Polarity test
DUSPOLE• Expert• Dust and waterproof• Vibration• Phase sequence• Continuity with buzzer• LED indicators• Measuring point illumination• Polarity test
TCV6• Voltage Tester• Dust and waterproof• Voltage indication with LED
1.0
52
Compliance Testers - Selection GuideInstruments
ELECTRIC SAFETY MEASUREMENTS MACROG3 T419 T60
PAGE 53 53 53
True RMS • • •
Insulation with voltage 50, 100, 250, 500, 1000V DC • • •
Continuity of protective conductors with 200mA / 10A • • •
Tripping time and current of RCDs type B, A, AC Standard, Selective and Delayed up to 1A
200mAOnly A, AC general and
selective200mA
Tripping time and current of earth leakage relaystype B, A, AC Standard, Selective and Delayed up to 10A
•*** •***
Non-trip earth resistance • • •
Earth resistance with rods • •
Earth resistance with stakeless testing method •** •**
Ground resistivity by 4-wire method • •
Loop/Line impedance, Phase-Phase, Phase-Neutral, Phase-PE • • •
Loop/Line impedance Phase-Phase, Phase-Neutral, Phase-PE with high resolution (0.1mΩ)
•* •* •*
Measurement of percentage voltage drop on the line • •
Contact Voltage • • •
Phase Sequence • • •
Leakage current with optional clamp meter • • •
POWER ANALYSIS
Measurement of Voltage, Current, Active, Reactive, Apparent Power (1) •
Measurement of Cosphi, Power Factor (1) •
Voltage and current harmonics up to the 49th with calculation of THD% 25th •
ADDITIONAL CHARACTERISTICS
Safety category CAT III 240V CAT III 240V CAT III 300V
Automatic test (Ra, RCD, Insulation) • •
Measurement of environmental parameters (°C, °CF, %RH, Lux) •* *+
Test with remote lead PR400 • • •
Help on screen display • • •
Internal memory for measured data saving • • •
Optical/USB serial port for PC connection • • •
Integrated WiFi connection and compatibility with HTANALYSIS App • •
Size (L x W x H) mm 222 x 16 2x 57 222 x 162 x 57 222 x 162 x 57
Weight (batteries included) Kg 1.2kg 1.2kg 1.2kg
Reference standard for safety IEC/EN61010-1 IEC/EN61010-1 IEC/EN61010-1
IP degree 50 50 50
* Optional accessory TIMP57** Optional accessory clamp T2100 *** Optional accessory RCDX10 (1) Single-phase or balanced three-phase system+ Optional accessory HT52/05
1.0
53
InstrumentsCompliance Testers
Power Source 6 x 1.2V type AA rechargeable batteries, 6 x 1.5V type AA alkaline batteries
Standard Accessories3 Terminal cable with SHUKO plug, Set of 4 cables + 4 alligator clips + 2 test leads, TEARTHKIT - Set of 4 cables + 4 metal earth probes, Carrying bag, Windows software + optical/USB cable, PR400 - Switch probe, External battery charger
Optional Accessories USB Cable T2100 Earth Clamp
Certificates Calibration certificate ISO9000, Certificate of Conformance
Model Specification
Power Source 6 x 1.5V batteries type AA
Standard Accessories Test leads, Carry case, English Instruction Manual
Optional Accessories TOPVIEW Software and USB Cable
CertificatesIEC/EN61010-1. IEC/EN61557-1-2-3-4-6-7, Calibration Certificate ISO9000, Certificate of Conformance
Model Specification
http://www.hellermanntyton.co.za/downloads.html
Application video
http://www.hellermanntyton.co.za/downloads.html
Application video
http://www.hellermanntyton.co.za/downloads.html
Application video
CAT III 240V
CAT III 240V
TRMS
CAT IV 300V
Power Source 6 x 1.2V (rechargeable) AA or 6 x 1.5V AA batteries or 10W power supply
Standard Accessories
HTFLEX33E 4pcs 3000A AC flexable clamps 174mm, C2033X - 3 Banana to shuko plug cable, UNIVERSALKITG3 - Set of 4 cables, KITTERRNE - 4 earth rods and cables in bag, PR400 - Remote switch , PR400 - Stylus, BORA2051 - Soft carry bag, TOPVIEW 2006 - PC softwre & optical-USB connection cable, Hands free kit
Certificates IP 40. EN61010-1, EN61326-1, EN61557-1-2-3-4-5-6-7-10, EN50160, EN60909-0
Model Specification
MACROG3 (23kA L-N) (40kA L-L)Advanced multifunction device for verification of electric safety of domestic and industrial electric systems (IEC/EN61557-1)
• Compliance Tester• Earth resistance by voltammetric method with 2 or 3 poles in TT, TN and IT systems,
non-trip earth resistance measurement and earth resistance with stakeless testing method with clamp meter T2100 (optional). Ground resistivity
• Measurement of electric parameters in single-phase installations (V, I, W, VAR, VA, PF)
• Test of RCDs type A, AC, B up to 1A, earth leakage relays with test current up to 10A (with optional accessory RCDX10)
• Measurement of insulation resistance• Touch-screen colour
T419 (23kA L-N) (40kA L-L) Multifunction device for tests on domestic and industrial systems
• Compliance Tester• Continuity of protective conductors with 200mA• Insulation with 50, 100, 250, 500, 1000VDC• Loop/Line impedance P-N, P-P, P-PE also with high resolution (0.1mΩ) with optional
accessory IMP57• Non-trip earth resistance• Phase sequence rotation• Memory storage of results• Optical/USB interface for PC connection• Global Earth Resistance
T60 Compliance/3-Phase Power Analyser• 362 Parameters over 2 months• Voltage anomalies (sags and swells)• Real-time display of wave forms • Earth resistance 2 or pole• 4 pole soil resistivity method • RCD type testing, A, AC, B up to 10A• Insulation resistance up to 1000V• Advanced loop testing of MCBs• WiFi connectivity• Power factor• THD (Total Harmonic Distortou) 49th Harmonic• Verification of phase sequence and leakage currents
TRMS
TRMS
54
1.0 Power Analyser - Selection GuideInstruments
*Through App HTANALYSIS **Adapter ACONBIN necessary
MAIN MEASUREMENTS T824 T78 TPQA820
PAGE 55 55 55
AC/DC voltage in single-phase/three-phase systems • • •
AC/DC current in single-phase/three-phase systems • • •
Cosphi, Power Factor • • •
Voltage unbalance (NEG%, ZERO%) • • •
Active, reactive, apparent power/energy and DC power • • •
Voltage and current harmonics up to the 49th with THD% • • •
Voltage anomalies (dips, peaks) with 10ms resolution (@ 50Hz) • • •
Voltage fast transients (spikes) with 5µs resolution •
Electric motor starting current (INRUSH) •
Voltage flickers (Pst, Plt) •
Phase sequence • • •
Neutral-Ground Voltage • •
Neutral current • • •
MEMORY AND RECORDING
Max number of simultaneously selectable parameters 251 251 383
Recording with selectable integration period 1s-60n 1s-60n 5s-60s
Indicative memory duration(in days @ PI=10min @ max number of parameters)
90 days 90 days 30 days
Indication of recording duration • • • *
Internal memory capacity 50MB 15MB 8MB
External compact flash card • •
Default and custom recording • •
Saving instant sampled value • • • *
REAL-TIME DISPLAY
Summary table of main electric parameters • • • *
Voltage/current waveforms • • • *
Tables or histograms of Harmonics and THD% • • • *
Voltage/current vector diagram • • • *
ADDITIONAL CHARACTERISTICS
Safety category
Measurement with use of external CT and VT (with optional accessory HT903 • • •**
Touchscreen colour display • •
Power supply and rechargeable battery recharging • •Auto power
supplied
Auto Power Off (APO) • • •
USB port for data download onto Pen Drive • • Only PC
Provided PC interface with software for Windows USB USB WiFi/USB
Context help active on each screen • •
Protection password on recording • •
Size (L x W x H) mm 235 x 165 x 75 235 x 165 x 75 255 x 200 x 115
Weight (batteries included) Kg 1 1 0.7
Reference standard for power quality EN50160 EN50160
Reference standard for safety IEC/EN61010-1 IEC/EN61010-1 IEC/EN61010-1
CAT IV 600V CAT IV 600V CAT IV 300V
55
1.0Power AnalysersInstruments
T78• 3-Phase Power Quality Analysers• 251 Simultaneous parameters on single-phase and 3-Phase 3-wire
and 4-wire systems• 5 Input channels for voltages and 4 input channels for currents• Numerical and graphic display (waveforms)• Recording of voltage anomalies (dips, peaks) with 10ms resolution• Up to 49 Harmonic power factor• Colour touch-screen
TPQA820• 3-Phase and single-phase power quality analysers• WiFi• Max 415 between inputs• AC TRMS voltage in single-/3-Phase systems• AC TRMS current in single-/3-Phase systems• Vibration• Calculation and recording of voltage/current THD%• iPad Mini
http://www.hellermanntyton.co.za/downloads.html
Application video
iPad Mini (Wi-Fi only supplied with product)
Power Source Rechargable Lithium-Ion battery
External Power Source 100 ÷ 415V, 50/60Hz
Operating Temperature 0 to 40°C
PC interface USB 2.0 and WiFi
Certificates IP65, IEC61010-1. Certificate of Conformance
Model Specification
http://www.hellermanntyton.co.za/downloads.html
Application video
Power Source1 x 3.7V rechargeable Lithium-Ion battery, with external adapter, duration >3h, auto power off after 5 minutes’ idling
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
Power Source1 x 3.7V rechargeable Lithium-Ion battery, with external adapter, duration >3h, auto power off after 5 minutes’ idling
Certificates UL, IEC61010-1. Certificate of Conformance
Model Specification
CAT III 600V
CAT III 600V
CAT IV 300V
T824 • 3-Phase Power Quality Analyser and Recorder• Simultaneous measurement of power parameters on single-phase
and 3-Phase 3-wire and 4-wire systems• 5 Input channels for voltages and 4 input channels for currents• Numerical and graphic display (waveforms)• Recording of voltage anomalies (dips, peaks) with 10ms resolution
TRMS
TRMS
TRMS
56
ACCESSORY T824 T78 TPQA820
PAGE 55 55 55
TOPVIEW2007 PC Windows software + USB cable
• • •
BORSA2051 Soft carrying bag for device/accessories
O O
A0055 External power supply AC/DC
• •
KITMPPACC Set of 4 alligator clips for AC voltage
•
KITMPPACW Set of 4 cables for AC voltage 2m
•
TKIT800 Set of 5 cables, black, Red, green, Blue and brown with alligator clips
• •
606-IECNConnector with magnetic terminal
O O •
ACONBIN Adapter for connection standard clamps
O
HTFLEX33E Flex 3000A AC clamp, max diameter of cable 174mm
• •
TFLEX33L Flex 1000A AC clamp, diameter 174mm
•
HTFLEX35Flex 3000A AC clamp, max diameter of cable 274mm
O O O**
HT96U Standard AC clamp 1-100-1000A/1V, diameter 54mm
O O O*
HP30D1 Standard DC clamp 1000A/1V, diameter 83mm
O O O*
HT4005K Standard AC 200A/1V clamp, diameter 40mm
O O O*
HT4005N Transducer AC 5A-100A/1V
O O O*
O Optional* Adapter ACONBIN necessary** Max measurement 1000A AC
1.0 Power Analyser Accessories- Selection GuideInstruments
57
ACCESSORY T824 T78 TPQA820
PAGE 55 55 55
TOPVIEW2007 PC Windows software + USB cable
• • •
BORSA2051 Soft carrying bag for device/accessories
O O
A0055 External power supply AC/DC
• •
KITMPPACC Set of 4 alligator clips for AC voltage
•
KITMPPACW Set of 4 cables for AC voltage 2m
•
TKIT800 Set of 5 cables, black, Red, green, Blue and brown with alligator clips
• •
606-IECNConnector with magnetic terminal
O O •
ACONBIN Adapter for connection standard clamps
O
HTFLEX33E Flex 3000A AC clamp, max diameter of cable 174mm
• •
TFLEX33L Flex 1000A AC clamp, diameter 174mm
•
HTFLEX35Flex 3000A AC clamp, max diameter of cable 274mm
O O O**
HT96U Standard AC clamp 1-100-1000A/1V, diameter 54mm
O O O*
HP30D1 Standard DC clamp 1000A/1V, diameter 83mm
O O O*
HT4005K Standard AC 200A/1V clamp, diameter 40mm
O O O*
HT4005N Transducer AC 5A-100A/1V
O O O*
1.0Photovoltaic Instrument - Selection GuideInstruments
MAINTENANCE AND EFFICIENCY OF THE PHOTOVOLTAIC SYSTEM
SOLARIV IV500 SOLAR300N PVCHECK
PAGE 61 61 62 62
Continuity of protective conductors with 200mA •
Insulation measurement with test voltage 250, 500, 1000V DC with no service interruption
•
I-V Curve measurement on single module or string •
VOC and ISC measurement on single module or string
• •
Single-Phase and Three-Phase efficiency measurement
1MPPT 1MPPT
DC side ef ciency of the photovoltaic field • •
Use of remote unit SOLAR02 with USB \ RF connection
RF USB RF
Measurement of irradiation with reference cell • • • •
Temperature measurement of cell and environment • • • •
POWER QUALITY ANALYSIS
AC/DC voltage in single-phase/three-phase systems • DC
AC/DC current in single-phase/three-phase systems • DC
Cosphi, Power Factor •
Voltage unbalance (NEG%, ZERO%) •
Power/Energy: Active P, Reactive Q, Apparent S Only active P • Only active P
Voltage and current harmonics up to the 49th with THD%
•
Voltage anomalies (dips, peaks) with 10ms resolution (@ 50Hz)
•
Voltage fast transients (spikes) with 5µs resolution (200kHz)
•
Electric motor starting current (INRUSH) •
Voltage flickers (Pst, Plt) •
Full analysis according to EN50160 •
Phase sequence •
Neutral-Ground Voltage •
Neutral current •
MEMORY AND RECORDING
Internal memory capacity249 curves I-V
8 days@ PI =10 min
249 curves I-V15MB
90 days@ PI =10 min
999Locations
Recording with selectable integration period 5s-60m 5s-60m 5s-60m
Indicative memory duration(in days @ PI=10min @ max number of parameters)
8 90
Indication of recording duration for power quality analysis
•
Internal memory extension with Compact Flash card •
Default and custom recordings •
REAL-TIME DISPLAY
Summary table of main electric parameters • • • •
Voltage/current waveforms •
Tables or histograms of Harmonics and THD% •
Voltage/current vector diagram •
1.0 Photovoltaic Instrument - Selection GuideInstruments
58
ADDITIONAL CHARACTERISTICS SOLARIV IV500 SOLAR300N PVCHECK
Measuring range of I-V Curve / IVCK1500V/ 10A1000V/ 15A
1500V/ 10A 1000V/ 15A
1000V/15Aonly VOC and ISC
Measuring range for efficiency measurement 1000V DC/ 265V AC1000V AC-DC
3000A
Safety category CAT III 300 CAT III 300 CAT IV 600 CAT III 300
Touchscreen colour display •
LCD display with backlight • • •
USB port for data download onto Pen Drive •
PC interface with software for Windows • • • •
Integrated WiFi interface • •
Custom management of internal PV module database
• • •
Power supply with rechargeable battery and battery charger
•
Auto Power Off (APO) • • • •
Indication of recording duration for efficiency measurement
• •
Reference standard for Power Quality Analysis EN50160
On display help • • • •
Size (L x W x H) mm 235 x 165 x 75 235 x 165 x 75 235 x 165 x 75 235 x 165 x 75
Weight (batteries included) kg 1.2 1.2 1 1.2
Reference standard for safety IEC/EN61010-1 IEC/EN61010-1 IEC/EN61010-1 IEC/EN61010-1
TroubleshootingIf system efficiency is lower than expected, it is necessary to detect the defective modules so that they can be replaced. This can be achieved by measuring the I-V curve with devices SOLARIV and IV500.
Solutions for Performance and TroubleshootingCommissioning TestsWhen operating a photovoltaic system, it is necessary to certify its safety according to IEC62446. The suitable device to carryout these verifications is PVCHECK.
PerformanceSystem performance monitoring it is possible to detect production loss quickly and efficiently. SOLAR300N and SOLARIV can record the energy production of a system and the inverter performance check over time thus preventing unneccessary maintenance.
ºC
W/m2
ACDC
KwhKwh
COMBINERBOX
SOLARIVIV500
SOLAR300NSOLARIV
Three-phaseSingle-phase
PVCHECK
MAINS
LOADSINVERTER
1.0Photovoltaic Instrument Accessories - Selection GuideInstruments
59
ACCESSORY SOLARIV IV500 SOLAR300N PVCHECK
PAGE 61 61 62 62
TOPVIEW2006TOPVIEW2007PC Windows software+ USB/ optical cable
TOPVIEW2006 TOPVIEW2007 TOPVIEW2006
PT300N PT1000 probefor PV module tempera-ture
• • O
SOLAR02Remote unit for Irradiationand Temperature
• O • O
KITGSC4 Set of 4 cables+ 4 alligator clips
• • •
KITPVMC3 - KITPCMC3Set of 2 adapterswith connectors MC3
KITPVMC3 KITPVMC3 KITPCMC3
KITPVMC4 - KITPCMC4Set of 2 adapters with connectors MC4
KITPVMC4 KITPVMC4 KITPVMC4
TKIT800 Set of 5 cables+ 5 alligator clips
•
A0055External power supply AC/DC battery charger 230V 50/60Hz
•
PT400Touch-screen pen
•
HT304NSensor for irradiation measurement
• • • O
M304Mechanical inclinometer
• • O
HT4004NStandard 10-100A DC clamp, diameter 32mm
• •
O Optional
ACCESSORY SOLARIV IV500 SOLAR300N PVCHECK
PAGE 61 61 62 62
HT4005KStandard 200A AC clamp,diameter 40mm
• •
C2007USB cable
•
BORSA2051Soft carrying bag
•
VA500Rigid carrying case
• • •
HT97UStandard clamp 10-100-1000AAC, diameter 54mm
O O
HTFLEX33EFlex 3000A AC clamp,diameter 174mm
O
HP30D1Standard 1000A DC clamp,diameter 83mm
O O
HP30C3Standard 3000A AC clamp,diameter 70mm
O
HP30C2Standard 200-2000A ACclamp, diameter 70mm
O
606IECNMagnetic connectorsfor voltage measurement
O O O
O Optional
60
1.0 Photovoltaic Instrument - Selection GuideInstruments
61
1.0Photovoltaic InstrumentsInstruments
Power Source 6 x 1.5V AA Alkaline batteries
Model Specification
Power Source 6 x 1.5V AA Alkaline batteries
Model Specification
Measuring of curve IV with environmental sensors Measuring single-phase efficiency with remote environmental sensors
* Measuring a IV curve via remote synchronisation of irradiation and temperature Measuring of curve IV with environmental sensors
CAT III 300V
CAT III 300V
SOLARIVDevice for tests and maintenance of single-phase installations
• Measurement of efficiency of a single-phase photovoltaic system• Measurement of I-V Curve of a module or of a string• Measurement of open-circuit voltage and of short-circuit current Voc/Isc• Database of 30 000 selectable photovoltaic modules• Measurement of PV module/string output voltage up to 1500V DC• Measurement of PV module/string current up to 10A DC• Measurement of resistance of series Rs of panels• DC/AC TRMS single-phase voltage• DC/AC TRMS single-phase current• * Measuring a IV curve via remote synchronisation of irradiation and temperature. Refer to IV500.
IV500Device for maintenance and troubleshooting
• Measurement of open-circuit voltage and of short-circuit Vos/Isc• Measurement of PV module/string output voltage up to 1500V DC• Measurement of PV module/string output current up to 10A DC• Direct comparison with reference conditions (STC - 1000Wm2 25°C) • Internal memory for data saving
ºC
PT300N
W/m2
SOLARIV
IV500
HT304NPT300N
ºC W/m2
IV500
RF Synchro
HT304NPT300N
SOLARIV
ºC W/m2
RF Synchro
SOLAR02
ºCW/m2
HT304NPT300N
LOADS
AC DCMAINS kWhkWh
SOLARIV
INVERTER
62
1.0 Photovoltaic InstrumentsInstruments
PVCHECKEarth
Connection diagram 3-Phase System
CAT III 600V
Power Source 6 x 1.5V AA Alkaline Batteries
Model Specification
HT304N
SOLAR02
CAT III 300V
“Whole photovoltaic field“ insulation measurement method Measuring efficiency of photovoltaic field
SOLAR300NDevice for vertification of single-phase and 3-Phase PV system efficiency and power quality analysis in compliance with standard EN50160
• Verification of the efficiency of photovoltaic system• Analysis of power quality and energy consumption• DC/AC TRMS voltage (single-phase and 3-Phase)• DC/AC current (single-phase and 3-Phase)• DC/AC active power (single-phase and 3-Phase)• Power factor cosj (single-phase and 3-Phase)• Solar radiation• Panel and environment temperature• Display of testing result (OK/NOT OK)• Remote unit SOLAR02 for measuring irradiation and temperature• Periodic recording of power parameters with programmable PI• Analysis of recordings• Voltage anomalies and spikes
PVCHECK and PVCHECK PRODevice for commissioning tests of electric safety and performance
Automatic test in a sequence of: • Measurement of insulation up to 1000VDC• Open-circuit voltage and short-circuit current Voc/Isc• Continuity of protection conductors with 200mA• Internal memory and USB output for PC Connection• Efficiency measurements of the photovoltaic system• Efficiency measurement of the photovoltaic field (DC side)
Code Description
SOLAR02 Remote unit to record irradiation and temperature
HT304NKit of 5 cables + alligator clips for voltage measurement Sensor for irradiation measurement
PT300N Probe PT1000 for panel temperature
PVCHECK PRO
SOLAR02
Synchronisedwith SOLAR300N
ºCW/m2
HT304NPT300N
AC DC
kWh kWh
SOLAR300N
INVERTERMAINS
LOADS
LOADS
MAINS kWhkWh
PVCHECK
INVERTER
SOLAR02
HT304N
ºCW/m2
RF Connection
PT300N
63
1.0CalibratorsInstruments
DC voltage (generated and measured)
Range 0.01mV ÷ 10V
Resolution 0.01mV ÷ 0.001V
Accuracy ±(0.02%rdg + 4dgt)
Protection 30VDC
DC current (generated and measured)
Range I0.001mA ÷ 24mA
Percentage -25% ÷ 125%
Resolution 0.001mA
Accuracy ±(0.02%rdg + 4dgt)
Protection 30mADC
DC voltage (generated and measured)
Slower linear ramp from 0% 100% 0% in 40s
Faster Linear ramp from 0% 100% 0% in 15s
Step ramp from 0% 100% 0% in steps of 25% with rampsof 5s each
Technical Overview
Standard AccessoriesTest Leads, Alligator Clips, Protection Rubber Holster, Lithium-Ion Rechargeable Battery, External Adapter, User Manual, Carrying Case
Model Specification
Output Measuring Range
Output Range Resolution Accuracy Remark
DCV
100mV1000mV10V
-10.000mV to 110.000mV-100mV to 1100mV-1.0000 to 11.0000V
1µV10µV0.1mV
0.02 + 0.010.02 + 0.010.02 + 0.01
Max ouput current: 0.5mA Max ouput cur-rent: 2mA Max ouput current: 5mA
DCA 20mA 0.000mA to 22.000mA 1µA 0.02 + 0.02 Max load 1kΩ at 20mA
Resitance400Ω4kΩ40kΩ
0.00Ω to 400.00Ω0.0000kΩ to 4.0000kΩ0.000kΩ to 40.000kΩ
0.01Ω0.1Ω1Ω
0.02 + 0.020.05 + 0.0250.1 + 0.1
Current 0.5 to 3mACurrent 0.05 to 0.3mACurrent 0.01mA
Temperature
RSBEKJTN
-0ºC to 1767ºC-0ºC to 1767ºC600ºC to 1820ºC-200ºC to 1000ºC-200ºC to 1372ºC-200ºC to 1200ºC-250ºC to 400ºC-200ºC to 1300ºC
1ºC1ºC1ºC0.1ºC0.1ºC0.1ºC0.1ºC0.1ºC
1.5ºC1.5ºC1.5ºC0.6ºC0.6ºC0.6ºC0.6ºC1.0ºC
ITS-90 temperature scale: The accuracy does not include the error of internal temperature compensation caused by a sensor
RTD
PT100-385PT200-385PT500-385PT1000-385
-200ºC to 800ºC-200ºC to 630ºC-200ºC to 630ºC-200ºC to 630ºC
0.1ºC0.1ºC0.1ºC0.1ºC
0.3ºC0.8ºC0.4ºC0.2ºC
Temperature scale ITS-90. Current varies from 0.5 to 3mA. Does not inculde lead resistance
Frequency
100Hz 1kHz10kHz100khz
1Hz to 110.00Hz0.100kHz to 1.10kHz1.0kHz to 11.0kHz10kHz to 110kHz
0.01Hz1Hz0.1kHz2kHz
2 count2 count2 count2 count
Output voltage 1 to 11Vp-pAmplitue accuracy 5% + 0.5VMax load > 100kΩDuty cycle 50%
Pulse100Hz1kHz10kHz
1 to 100000 cycles1 to 100000 cycles1 to 100000 cycles
1 cycle1 cycle1 cycle
2 count2 count2 count
Switch100Hz to 100kHz
1Hz to 110kHz 0.1Hz to 2kHz
5 count Max open/close voltage 28V and 50mA
Technical Overview
Power Source 1 x 9V Battery
Model Specification
T8051• Process Calibrator• Generation of output voltage signal with amplitude up to 10VDC• Voltage measurement up to 10VDC• Generation of output current signal with amplitude up to 24mADC• Current measurement up to 24mAVDC• Current measurement under percentage format (4-20mA)• Adjustment selector with high sensitivity• Up to 3 available automatic ramp selection
T123 • Process Calibrator• Only for sourcing and not for input voltages
64
1.0 Test LeadsInstruments
CAT IV 1000V
CAT IV 600V
CAT III 1000V
T02AS• Universal • Suitable for all testers with 4mm terminals• Budget test lead set with probe and crocodile clips• Silicon based
TAL24• Universal• Suitable for all DMM’s• 2mm Probe tip• PVC test leads• C/W crocodile clips• Screw on crocks
TALTBM• Silicone• IEC61010-1• Ideal for TBM SEE PG 13-18 meters
TAL25 • Universal• Suitable for all DMM’s• 4mm Probe tip• PVC test leads• C/W crocodile clips• Slide on crocks
TAL35RBK• Silicone• General Multimeter use• Double insulated Silicone wire (1m)• Spring-shrouded 4mm brass caged
banana probe tips• Shrouded right-angle connector• IEC1010
T8040LEAD• Universal • Suitable for all Toptronic and Fluke 70 series• Budget test leads
65
1.0Test LeadsInstruments
CAT III 1000V
TALTIN • Double insulated silicone wire (1.2m)• Used for TIN insulation testers
TIN4D - SEE PG 38 TIN5D - SEE PG 39 TIN6A - SEE PG 39 TIN6D - SEE PG 39 TIN7D- SEE PG 40
TAL30CRBK• Accessories• Wide grip crocodile clip with integral finger guard• Suitable for use with TAL35RBK test leads• Compatible with 4mm male leads
TAL30ARBK• Silicone• Double insulated silicone wire (1m)• Wide grip crocodile clips with integral finger guard• IEC1010• Straight shroud terminations
TAL1825• Accessories• Short length to reduce resistance
with loop test• Used for loop testers T1825 - SEE PG 41
TAL38CRBK• Accessories• Wide grip crocodile clips with integral finger guard• Suitable for all 4mm male leads• Suitable for use with TAL39RBK test leads
TAL39RBK• Silicone• Double insulated silicone wire (1.2m)• Straight shroud terminations both sides
1.0 Test LeadsInstruments
66
Colour Size
Red 15m
YELLOW 10m
BLACK 10m
GREEN 5m
Colour Size
Red 30m
YELLOW 20m
GREEN 5m
Accessories Earth bar, Alligator clip
TKPS54BK /TKPS54RD• Accessories• Flexible shaft with twin pointed gripping jaws
Colour: RD - Red BK - Black
• Compatible with 4mm male leads
TAL36• Wide grip alligator clips with 35mm spring mouth• PVC insulated wire
TELEWR50F• 4mm Brass banana plug• Soft PVC insulated wire• 50m braided copper wires
TEARTHKIT• Used for earthing testers
T416 - SEE PG 31 MACROG3- SEE PG 53 T60 - SEE PG 53
TAL36L• For 3-wire earth resistance test• Wide grip alligator clips with 35mm spring mouth• PVC insulated wire
1.0Cable Avoidance DetectorsInstruments
67
VSCAN• Compass (cable avoidance detector)• Self-test and calibration verification• Metal cover locating mode• Lithium ion rechargeable batteries• Internal or external GPS• Rotary control for sensitivity• Depth and current measurement (configurable)• Bluetooth• 1 Watt • 33kHz and 131kHz simultaneously applied by direct connection,
induction or optional induction clamp
VSCANM• Cable avoidance detector• Self-test and calibration verification• Metal cover locating mode• Lithium ion rechargeable batteries• Rotary control for sensitivity• Depth and current measurement (configurable)• 33kHz and 131kHz simultaneously applied by direct connection,
induction or optional induction clamp
LPC - Live Plug ConnectorThe LPC separation filter is used to inject and locate frequency into a live cable via a domestic power socket to trace the services from the building to the connection in the street. Between 100 V AC and 250 V AAC
68
1.0 Cable Route TracersInstruments
Sensitivity Max depth
Dynamic Range SL, DL, DLG, PL, PLG, TL and TLG
Depth in Power PL, PLG
Technical Overview
CAT4PLUS The C.A.T4 Avoidance ModeTM searches for power, radio and Genny4 signals, and pinpoint located utilities, in a single scan. The bargraph ‘tidemark’ enables the user to quickly spot and zero-in on a buried conductor.
• Cable And Pipe Locator• eCert™ – remote calibration validation to form part of an annual service regime• Avoidance instrument, not cable fault locator• Provides four functions, audio and visual indication and depth estimation in
genny mode• Signal strength indicator• Mode/clockface indicator
The Genny4 transmits a specialised small diameter Locate frequency which facilitates location of utilities such as telecoms and street lighting, including spurs. C.A.T4’s Dynamic Overload Protection feature automatically filters out high levels of interference, eg. electrically noisy areas such as substations and under high-voltage cables.
Avoidance ModeTM
Avoidance Mode speeds the process of pre-digital scanning by searching for power, radio and Genny signals simultaneously.
RD7100• Excavation of buried utilities easier and safer• Simultaneous depth and current readout• Dynamic overload protection• Power filtersTM
• TrudepthTM
• Guidance mode• Automatic usage-logging with GPS positioning• ECERTTM - Remote calibration without downtime• Ingress protection for tough environments (IP65)
VLOCPRO2• Rugged ABS and carbon fibre construction• IP54 rating for all weather use• Colour display• High speed dual core processor• Multiple location modes with compass orientation• Multiple frequencies (over 70 are pre-programmed)• Push button and continuous depth/current (feet or meters)• Rechargeable and alkaline battery packs• Combined GPS location with locate data (such as depth, current, etc.)
Power Source Alkaline, NiMH or Li-Ion
Standard Accessories TX-1, RX
Model Specification
69
1.0High Voltage TestersInstruments
Telescopic Hot Stick - Hastings
VTT25F • 6 Sections• 7.78m (25ft) Length when extended• Voltage range 1 to 132kV• Rubber hook latch• Base cap for better stability • Triangular design for easy operation
VTT30F• 7 Sections• Suitable for voltage ranging 1 to 132kV• Rubber hook latch• Base cap for better stability • Triangular design for easy operation
C4031601 (SH250)• Voltage range 1 to 132kV
CSH230 (SH230)• Voltage range 1 to 132kV
Length Extended 7.78m (25ft)
Standard Accessories Heavy Duty Carry Bag
Certificates
Certificate of ConformanceASTM F 1826-00 specification
Model Specification
Length Extended 7.62m (25ft)
Standard Accessories Heavy Duty Carry Bag
Certificates Calibration Certificate
Model Specification
Length Extended 9.18m (30ft)
Standard Accessories Heavy Duty Carry Bag
Certificates
Certificate of ConformanceASTM F 1826-00 specification
Model Specification
Length Extended 9m (30ft)
Standard Accessories Fuse Hook, Bag
Certificates Calibration Certificate
Model Specification
T99FD - Fuse disconnect included
Telescopic Hot Stick - Ritz
70
1.0 High Voltage TestersInstruments
THS25F• Triangular - shaped design keeps sections aligned during extension and retraction• Withstands voltage rating of 100kV from 30cm for 5min• Universal end fitting
THS30F• Triangular - shaped design keeps sections aligned during extension and retraction• Withstands voltage rating of 100kV from 30cm for 5min• Universal end fitting
Length Extended 7.78m
Standard AccessoriesDisconected hook and carry bag
Sections 6
Certificates IEC 62193
Model Specification
Length Extended 9.18m
Standard AccessoriesDisconected hookand carry bag
Sections 7
Certificates IEC 62193
Model Specification
TPCAA90 - 90º Angle bends for the TPC Series (Optional Accessory)
ELECTRICAL
Model TPC7K TPC11K* TPC22K TPC33K* TPC44K
System Voltage (kV) 6.6 11 22 33 44
Full Scale Voltage (kV) 8 12 24 36 48
Total Resistance (MΩ) 3.95 6.78 13.5 20.1 27
Response Time 1 Second
Neon Threshold 1.2 kV
MECHANICAL
Total Length (m) 1.105 1.105 1.225 1.375 1.525
Total Weight (kg) 1.2 1.2 1.3 1.4 1.5
Operating Temperature -25˚C to 55˚C
Operating Humidity 20 to 96% RH
Standard Accessories Carry Case, Instruction Manual, IEC Certificate
Optional Accessories 90˚ Bend TPCAA90
Certificates IEC61481:200, IECSPE8561481
Note: * - Standard stock items.
Technical Overview
Telescopic Hot Sticks
TPC7/11/22/33/44K• High Voltage Phase Comparators/Live
Line Tester/Voltage Detector• No user assembled parts• Dual colour coded scale (%, Vac)• Neon indicator lit when > 1200 Vac• Measure and test phase to earth
phase to phase• High quality fibreglass wound rod
• Self powered operation - no battery• Current is limited to Milliampere• Grounded or ungrounded systems• Lightweight, robust and compact• High immunity to interference fields• Silcone handles• Specified by town councils
71
1.0High Voltage TestersInstruments
Wireless Receiver
Wireless Transmitter
Technical Overview
System Voltage (kV) 11 to 33kV
Threshold Range (kV) 1.3kV
Response Time < 1 second
Spark ProtectionThe detector will not be damaged as a result of spark discharge while making contact with the conductor under test
Bridging ProtectionThe comparator and its accessories will not cause flashover between live parts of the installation or between live parts of the installation and earth/ground
Current Consumption 45 mA maximum
Range 30m in air
Visual Indicator Transmitter - 2 x Red LED’s / Receiver - 1 x Red LED + 1 x Green LED
Audible Indicator Buzzer present when IN Phase is indicated - > 65dB (5 metres)
MECHANICAL
Length(mm) Diameter (mm) Material
Y Electrode 35 40 Stainless steel
Hook 100 40 Stainless steel
Dimensions (mm) 180 (L) x 100mm (Dia.)
Weight 600g
Power Source 1 x 9V Battery
Standard Accessories Carry case, Cleaning Kit, 2 x Rose Connector, 2 x Y Contact, 1 x Hook
Certificates Certificate of Conformance IEC 61481
Model Specification
Technical Overview
MODEL T11338VD25E
System Voltage 11/33kV
Threshold Set within Range 1.65kV to 14.6kV
Response Time <1 Sec
Auto-OFF ±3 Min
Bridging Protection Yes
Spark Protection Yes
Battery Low <7V
Threshold 2.5kV
Battery Current <30mA
Green = Armed Yes
Red = V Detected Yes
WPC• Series High Voltage Wireless Transmitter Receiver Phasing Comparator
WPC1000 - 11kV-33kV Voltage range (As shown on this page)WPC3000 - 44kV-132kV Voltage range
• Wireless distance up to 200 metres• All weather use (indoor or outdoor)• Conductor is energised or de-energised to detect and indicate the correct phase
relationship between 2 enegised lines nominal voltage and frequency• IN phase or OUT of phase
T1133HVD25E• Designed for multi-voltage sites• Covers systems voltage from 11kV to 33kV
72
1.0 High Voltage TestersInstruments
Technical Overview
MODEL T213HVD T217HVD T218HVD T219HVD T220HVD T222HVD
System Voltage 11kV 11/33kV 6/22kV 44/132kV 6.6/132kV 11/44kV
Threshold Set within Range
1.65kV to 4.4kV
3.3kV to 4.95kV
1.8kV to 2.7kV
6.6kV to 19.8kV
1.65kV to 14.6kV
4.4kV to 5.0kV
Response Time <1 Sec <1 Sec <1 Sec <1 Sec <1 Sec <1 Sec
Auto-OFF ±3 Min ±3 Min ±3 Min ±3 Min ±3 Min ±3 Min
Bridging Protection Yes Yes Yes Yes Yes Yes
Spark Protection Yes Yes Yes Yes Yes Yes
Battery Low <7V <7V <7V <7V <7V <7V
Threshold 3.02kV 4.12kV 2.5kV 13.2kV 2.5kV 4.75kV
Battery Current <30mA <30mA <30mA <30mA <30mA <30mA
Green = Armed Yes Yes Yes Yes Yes Yes
Red = V Detected Yes Yes Yes Yes Yes YesLIFETIME WARRANTY
HVD• High Voltage Detector• Checks if HV system is alive or dead• All weather use (indoor or outdoor)
THVD • Contact Capacitive High Voltage Detector• Self starting and automatically activated when the High Voltage is applied to the
contact electrode• Use on sinusoidal (50 or 60Hz) High Voltage Systems• Models are available to cover systems voltage from 6.6kV to 132kV• IEC 61243-1 for voltages above 1kV 50/60Hz• Check system is dead or alive
Spark Protection The detector will not be damaged as a result of spark discharge
while making contact with the conductor under test
Bridging Protection The detector and its accessories will not cause flashover between live parts of the installation or between live parts of the installation and earth/ground
Current Consumption 30 mA maximum
Test Button Tests and arms the detector when pressed and released
Visual Indicator (2Hz) Red lamp (voltage present), green lamp (safe)
Audible Indicator Buzzer - 3.1 kHz tone modulated at 2 Hz - 70 dB (1.5 metres)
Mechanical
Length(mm) Diameter (mm) Material
Y Electrode 35 40 Stainless steel
Standard Accessories Carry bag, Cleaning kit, Rose Connector, Y Contact
Technical Overview
ELECTRICAL HVD13AC HVD32AC HVD33AC
System Voltage (kV) 6.6 to 132 11 to 33 44 to 132
Threshold Range (kV)
2.5kV 2.5kV 10kV
Non standard threshold voltages can be set outside the range to suit customers requirements
73
1.0High Voltage Testers and Automotive TestersInstruments
Ranges 240V, 3.3kV, 6.6kV, 11kV, 22kV, 33kV, 66kV, 132kV, 275kV
Detection Selection range is detected at approx. 25cm from the voltage
240V ±10cm, 33kV ±50cm
Self-Test Selection
Indicators Bright Red LED and buzzer
Technical Overview
Power Source 3 x 1.5V C Batteries
Standard Accessories Carry Pouch
Certificates Certificate of Conformance
Model Specification
VOLTAGE RANGE 6-50V
WARNINGNot for use on circuits exceeding 50 Volts
VOLTAGE RANGE 5A/50V
WARNINGNot for use on circuits exceeding 50 Volts.When using a multimeter, voltages from 0-50V can be measured. 5A MAX Rating.
T175HP (High-Prox)• Proximity Detector• Non-contact high voltage detector• Ten switch-selectable voltage sensitivity ranges• Lightweight• Audible and visual indication of live voltage• Rose adaptor • Check high frequency radiation
CBTL - Circuit Buddy 6 to 50• Volt Test Light• Automotive industry• Test for current on wiring, fuses etc • Safe and easy to use, especially when piercing wire• Use of LED’s instead of globes reduces the risk of damage to electronics
CBSPK - Circuit Buddy Safety Probe Kit(To be used with a digital multimeter)
• Automotive industry • Used with a standard multimeter• Easy and safe to pierce wires
74
1.0 Automotive TestersInstruments
Power Source 1 x 9V Battery
Standard Accessories RJ45 Cable, Case
Certificates Certificate of Conformance
Model Specification
T185• LAN Tester• LED Display• Network cable testing (RJ45)• Test any unenergised wire or cable• Auto and manual scan function• Lock status function• Verify cable continuity, open, short circuit and miss-wired• Buzzer sound warning for wire status
T5012• Carcheck• DC only• Polarity (LED display)• 3 - 48 Volts
75
1.0Tachometer TestersInstruments
Power Source 4 x 1.5V AA Batteries
Standard AccessoriesReflecting Tape Marks (600mm), RPM Adaptor (cone), RPM Adaptor (Funnel)Surface Speed Test Wheel
Model Specification
Power Source 4 x 1.5V AA Batteries
Standard AccessoriesCarry Case, Reflecting Tape Marks (600mm), RPM Adaptor (cone)RPM Adaptor (Funnel), Surface Speed Test Wheel
Model Specification
Power Source 4 x 1.5V AA Batteries
Standard Accessories Cables with plugs, Sensing Probe, Magnetic Base, Carrying Case, Vibration Probe
Certificate Certificate of Conformance
Model Specification
Technical Overview
Measurement and Range Photo: 2.5 to 999999 RPMContact: 0.5 to 19999 RPMSurface Speeda (m/min): 0.01 to 99.99 m/min
Resolution RPM M/Min
0.1 (0.5 to 999.9 RPM)0.01 (0.05 to 99.99 m/min)
Display 5 Digits, 18mm LCD
Accuracy ±(0.05% + 1 Digit)
Technical Overview
Measurement and Range Photo: 5 to 99.999 RPMContact: 0.5 to 19.999 RPMSurface Speed (m/min): m/min: 0.05 to 1999.9 m/min
Resolution RPM M/Min
0.1 (0.5 to 999.9 RPM)1 RPM (≥ 1000 m/min), 0.01 m/min (< 100 m/min.)
Display 5 Digits, 18mm LCD
Accuracy ±(0.05% + 1 Digit)
TAS35CSurface Speed Test Wheel
TMTL35AMetal Shaft of Cone
TAS35BRPM Adaptor (Funnel)
TA535ARPM Adaptor (Cone)
Feature Parameter Accuracy
Velocity 0.5 ~199.9mm/s ±5%+2 Digit @23 ±5°C
Acceleration 0.5 ~199.9m/s2
Frequency Range 10hz ~1khz
Min and Max Memory
Sampling Time Approx.1 Second
Operating Temperature 0°C to 50°C
Operation Humidity
Technical Overview
LIFETIME WARRANTY
T6236 • Digital Tachometer• Low cost• Photo/contact• Removable contact head• Backlit• Memory Last/Max/Min value
T2238• Digital Tachometer• Photo/contact• Microprocessor based• High accuracy• Variable LCD contrast• Holds last reading/recalls max and min
T8202• Vibration• Magnetic probe• Sensing probe
76
1.0 Digital TimersInstruments
Mounts on bothDin rail and mini rail
Mounts on bothDin rail and mini rail
Live In
LiveLoad Out
Live In Neutral
TIMERGeyser Circuit Breaker
Wiring diagram
Wiring diagram
Live InLive In
Live In (Volt Range: 1V to 250V AC)
Load Out (Max 20 Amps)Additional Contact (Max 20 Amps)
Neutral
Relay OutputN/C N/O COM
TIMER
Circuit Breaker
Inside Lid
Certificates IEC 60669-1, IEC 60669-2-2, IEC 60730-2-7, IEC 60730-1, RCC Certificate
Certificates IEC 60669-1, IEC 60669-2-2, IEC 60730-2-7, IEC 60730-1, RCC Certificate
Certificates IEC 60730-2-7, 60730-1; 60669-1, 60669-2-2 / RCC Certificate
TDDT7• 7 Day Digital Timer (Relay contacts)• Rated Voltage: 220 - 240V AC (50 - 60 Hz)• Relay contacts for various voltage ranges• Max 20A (3500 Watts) - resistive load (geysers, underfloor heating, lights)• Max 10A - inductive load (pool pump, aircon)• Day/Weekly 16 programmable settings• Din rail mounting• 3 Year backup battery• LCD displays real time hour/minute - on/auto/off
TDDGT• 7 Day Digital Geyser Timer (Internal relay)• Rated Voltage: 220 - 240V AC (50 - 60 Hz)• Max 20A (3500 Watts) - resistive load (geysers, underfloor heating, lights)• Max 10A - inductive load (pool pump, aircon)• Day/Weekly 16 programmable settings• Din rail mounting• 3 Year backup battery• LCD displays real time hour/minute - on/auto/off
TGTLC • Day Digital Geyser Timer (Internal relay)• Pre-programmed timer• Rated voltage 220 - 240V AC (50 - 60HZ) internal relay contact• Six preset times with peak demand lock out between
6:00 - 8:00AM and 18:00 - 20:00PM• Override option up to 2 hours on any program selection including peak
demand if required• 2 Program options out of peak demand• Time and date preset + 2Hr GMT (South Africa)• Weekend mode option• Max 20A (3500 Watts) (resistive loads geysers)• 1 Year backup battery • Time limit drift under 3 min/year• Din rail mounted • Mini rail adaptor (DINADAPT) • Electrostatic, Electromagnetic field immunity certification
77
1.0Digital TimersInstruments
Certificates IEC 60730
Certificates IEC 60730
TDT7• Digital 3 Pin Socket• Ideal for household use• Backup rechargeable battery • 8 Group programmable• 3500 Watt / 16 Amps
TMT2• 24 Hour Mechanical 3 Pin Socket• Ideal for household use• User friendly• 15 Minute increment adjustment• 3500 Watt / 16 Amps
TMDT2 • 24 Hour Mechanical Din Rail• 15 Day battery back-up• Ideal for household use in DBs• 15 Minute increment adjustment• 3500 Watt / 16 Amps
78
1.0 Thermometer - Selection GuideInstruments
FEATURE T3004 T8000 T500K T502KJ TIR9PEN T306 T151 T685
PAGE 79 80 80 81 81 81 82 82
Temperature Range-27°C to
60°C-100°C to 1300°C
-200°C to 1372°C
-200°C to 1370°C
-33°C to 500°C
-50°C to 700°C
-30°C to 650°C
-50°C to 1000°C
Probe/Sensor TypeSemi-
conductorK K K, J IR IR IR IR
Single/Dual Input Single Single Dual
Data Hold • • • • • • • •
Min/Max Display • • Max • • • • •
Resolution 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C
Backlight • • • • • •
High/Low Setting • • •
Auto Power Off (APO)
• • • • • • • •
Temperature Accuracy (°C)
±0.8°C 0.1°C±0.1% to
2°C±0.05% to
±0.7°C±2°C or
±2%±1.5°C to
±3°C ±1.5°C to
±2°C
±2°C to±3°C or
±2%
Range ºC -50 -20 0 100 200 300 900 1000 1100 1200 1300 1400
TP01
TP02A
TP03
TP04
TP04L
Temperature Probes (Type K) - Selection Guide
TP04 Surface contact probe
TP04L Surface contact probe
TP02A General purpose liquid probe
TP01 Bead probe
* Refer to Instruments for full technical data
79
1.0Environmental Testers and ThermometersInstruments
Weight 220g
Standard Accessories Carry Pouch
Certificates Certificate of Conformance
Model Specification
T325• Sound Level Tester• Type 2 sound level meter• Wide range• Sampling rate 2 seconds
• Bargraph• Min/Max hold• Frequency weighting A/C• Over range indications
T3004• Humidity/Temperature Meter• Data hold• Min/Max• REL function• Auto power off
Display 31/2 Digit LCD Display
Ranges 20, 200, 2000, 20000, 200000 Lux
Resolution 0.01 Lux
Overange OL display
Sampling Time 2.5 times/second
Sensor Material Silicon Photodiode
Accuracy ±3% rdg + 10dgts
Operating Temperature 0 to 50ºC
Operating Humidity < 70% RH
Technical Overview
Power Source 1 x 9V Battery
Standard Accessories Screw Driver, Instruction Manual, Carry Case, Wind Shield
Certificates Certificate of Conformance
Model Specification
Technical Overview
Display 3.5 Digit with Bar Graph
Function Fast (125mS)Slow (1000mS)
Measurement Ranges 30dB to 130dB
Level ranges Low 30dB to 80dB, Med 50dB to 100dB, Hi 80dB to 130dB
Display Update 2sec
Microphone 1/4inch (ECM)
Accuracy ±1.5dB @ 94dB of 1kHz
GENERAL
Output Impedance Approx 100Ω
Operation Humidity 90% RH
Operation Temperature 0˚ to 40˚C
Dimensions (mm) 240 (L) x 54 (W) x 34 (H)
Model Specification
Altitude Up to 2000meters
Temperature -20ºC to 60ºC
Humidity 0% RH ~ 100% RH
Resolution Temperature 0.1ºC / 0.1ºF
Resolution Humidity 0.1% RH
Response Time Humidity 180sec
Response Time Temperature 10sec
Operation Temperature 0ºC to 40ºC
Operation Humidity <80% RH
Sampling Rate 2.5 times per second
Calibration Internal calibration
RH Accuracy ±3% RH
Temp Accuracy ºC ±0.8ºC
Technical Overview
LIFETIME WARRANTY
T630• Digital Luxmeter• 0-200 000 Lux• Data hold• Max hold• Backlit
1.0 Environmental Testers and ThermometersInstruments
80
Power Source 1 x 9V Battery
Model Specification
Technical Overview
Measurement Range Resolution
m/s 0.4 – 30.0 0.1
km/h 1.4 – 108.0 0.1
Knots 0.8 – 58.3 0.1
Display 18mm LCD, 31/2 dgts
Accuracy ±(2% + 1 Digit) ≤ 25 m/s
Operating Temperature 0°C to 50°C
Dimensions Sensor Head: Round 72mm Dia.
Operating Humidity Max 90% RH, (0°C to 35°C)
Weight 160g
Model Specification
Technical Overview
AIR VELOCITY
Metres Per Second (m/s) 0.4 to 30.0 m/s
Kilometers Per Hour (Km/h) 1.4 to 108.0 km/h
Knots 0.8 to 58.3 Knots
Temperature -100 to 1300°C
Light Intensity 0.2, 200, 1800, 20000 Lux
Humidity 10 to 95%Rh
Metres Per Second (m/s) 0.1 m/s
Kilometers Per Hour (Km/h) 0.1 km/h
Knots 0.1 Knots
Temperature Accuracy 0.1°C/0.1°CF
LIGHT INTENSITY
0, 2, 200 Lux 1 Lux
1800 to 20.000 Lux 10 Lux
HUMIDITY
10 to 95%Rh 0.1%RH
Operating Temperature 0 to 50 °C
Operation Humidity 80%RH Max
Feature Parameter Accuracy
Temperature Range-200°C to 1372°C
-200°C to 1372°C, ±0.1% + 2°C -60°C to 1372°C, 0.1% + 1°C The accuracy specification does not include the probe accuracy.
Resolution 0.1°C/1°C
Technical Overview
Power Source 4 x 1.5V AAA Batteries
Standard Accessories Bead Probe
Model Specification
T4201• Anemometer• Low friction • Ball bearing design• Data hold• 4 Different speed units
T8000• Anemometer/Hygro/Lux/Temp• Display LCD• Auto power off
T500K• Professional Thermometer (Single Input)• K-type Thermocouple• 0.1 °C resolution• Hold function• Max hold• Backlit• Relative zero button
1.0ThermometersInstruments
81
Feature Parameter Accuracy
Temperature RangeType K: -200°C to1370°CType J: -200°C to 1050°C
-50°C to 1370°C, ± 0.05%, + 0.7°C-200°C to -50°C, 0.05% + 0.3°CThe accuracy specification does not include the probe accuracy.
Resolution 0.1°C/0.2°CF
Technical Overview
Power Source 4 x 1.5V AAA Batteries
Standard Accessories 2 x Bead Probe
Model Specification
Feature Parameter Accuracy
Temperature Range-50°C to 700°C / -58°CF to 1292°CF
0°C~700°C ±1.5°C-50°C to 0°C ±3°C
Resolution 0.1°C / 0.1°CF
Response Time 0.5 Second
Spectral Response 8 to 14µm Nominal
Emissivity Adj. 0.1 to 1
Relative Humidity 10~95%
Technical Overview
Feature Parameter Accuracy
Temperature Range -33°C to 500°C ±2% or 2°C
Resolution -9.99°C to 199.9°C 0.1°C
Response Time 1.0 Second
Wavelength 8 to 14µm
Technical Overview
Power Source 1 x 9V Battery
Standard Accessories 2 x Bead Probe
Model Specification
Power Source 1 x 1.5 AA Battery
Certification CE, RoHS
Model Specification
NOTE: Emissivity - is how infrared is emitted off a particular surface e.g. black is 1 and a very shiny surface like chrome, glass is around 0.3
T502KJ• Professional Thermometer (Dual Input)• K-type and J-type Thermocouple• Data hold • Programmable• Temp1/Temp2 dual display• High/low limit mode• Relative mode• Backlit
TIR9PEN• 9:1 Infrared• Hold Max - Min display• Circular laser• Compact size
T306• Non-contact Thermometer• Laser pointer• Emissivity adjustable• Distance and spot D:S (Field of view) 12:1• Max/Min/Average• High/Low temperature alarm setting
82
1.0 ThermometersInstruments
Feature Parameter Accuracy
Temperature Range -30°C to 650°C ≥-10°C to < 0°C ±2°C, ≥-0°C: ±1.5%
Resolution 0.1°C
Response Time < 300mS
Spectral Response 8 to 14 µm Nominal
Emissivity Adj. 0.1 to 1
Co-efficient ±0.1°C
Technical Overview
Power Source 3 x AA Batteries
Model Specification
Feature Parameter Accuracy
Temperature Range50°C to1000°C / 58°CF to 1832°CF
±3°C (±5°CF)from -50°C to -20°C±2°C (±3°CF)from -20°C to -100°C±2% from 100 to 1000ºC
Resolution 0.1°C / 0.1°CF
Response Time 0.5 Second
Repeatability ±1ºC or ±2ºF
Emissivity Adj. 0.1 to 1.0
Operating Temperature 0°C to 50°C 10-90% RH
Technical Overview
Power Source 1 x 9V Battery
Model Specification
NOTE: Emissivity - is how infrared is emitted off a particular surface e.g. black is 1 and a very shiny surface like chrome, glass is around 0.3
T151• 4-in-1 Non-contact IR Thermometer • UV refrigerant leak detector• Distance and spot size indicator • Coaxial laser in circle with scale indication of distance
and measured temperature area• D:S (Field of view) 15:1• High and low alarms for measurements outside the limit
T685• High Temperature / Non-Contact
Thermometer• Laser pointer • Dual display
• Emissivity adjustable• 10 Point memory• Distance and spot
D:S (Field of View) 30:1
1.0Thermal Images - Selection GuideInstruments
83
FEATURE THT45 TG301 THT60 TPK160
PAGE 84 84 85 85
CHARACTERISTICS OF IR IMAGE
IR Sensor Resolution (Pixels) 80 x 80 128 x 128 160 x 120 160 x 120
Temperature Range -20°C to 350°C -30°C to 650°C -20°C to 400°C -20°C to 350°C
Thermal Image Sensitivity < 0.1°C at 30°C 150mK (0.1°C ) ≤ 0.8°C at 30°C 0.8°C at 30°C
Spectrum Range 8 to 14µm 8 to 14µm 8 to 14µm
Type of IR Sensor UFPAIR-EXTM
(Integrated IR Array with CMOS Sensor)
UFPA
Frequency 50Hz 8Hz 50Hz
CHARACTERISTICS OF IR AND INTEGRATED OPTICS
Field of view 17° x 17° 33° x 33° 29.8° x 22.6° 24° x 32°
Focal length of standard lens 9mm 7.5mm Fixed
Interchangeable Optics •
FUNCTIONS
Laser • Circular •
Colour Palettes 4 Standard 3 Standard8 Standard,
10 Custom Colours6 Standard
Saved Image Format JPEG, MPEG4 Bitmap JPEG, MPEG4 JPG
Touch Screen • •
IP Rating IP50 IP50 IP65 IP54
Shock/Vibrations 25G/2G 50G/2.5G 25G/2G 25G/2G
Hot/Cold Spot Auto Auto
84
1.0 Thermal ImagersInstruments
Display 1.77” Colour TFT with 128 (H) x 160 (V) pixels
Temperature Range -30°C to 650°C
Accuracy (Calibration geometry with ambient temperature 23°C ±2°C)
≥0°C: ±1.5°C or ±1.5°C of reading, whichever is greater
Response Time (95%) <125ms (95% reading) (8Hz)
Spectral Response 8 to 14µm
Emissivity 0.10 to 1.00
Temperature Coefficient ±0.1°C/°C or ±0.1%
Measurement Resolution 0.1°C
Repeatability (% of reading) ±8% of reading or ±1.0°C, whichever is greater
Thermal Imaging detectorIR-EXTM Technology (Integrated IR Array Sensor with CMOS Sensor)
IR Resolution 16.384 pixels (128 x 128 pixels)
Field of View (H x W) 33° x 33°
Thermal Imaging Sensitivity 150mK
Colour Palettes 3 (Grey Scale, Hot Iron and Rainbow)
Save Image Format Bitmap (BMP) Image with Temperature and Emmissivity
Battery Life 12 hours with laser and backlight on
Technical Overview
TG301• 128 x 128 Pixels• Thermal IR camera• UV refrigerant detection• 30:1 distane to spot ratio• Bright flashlight• Circular laser• 1.2m Drop proof
http://www.hellermanntyton.co.za/downloads.html
Application video
Technical Overview
Temperature Range -20°C to 350°C
Thermal Sensitivity <0.1°C @ 30°C
Spectral Range 8 to 14µm
Image Frequency 50Hz
Digital Zoom 1x to 32x
IR Resolution 80 x 80 pixels
Colour Palettes 4 Standard
Integrated Photo Camera 1.3MP
Thermal Imaging Sensitivity 150mK
Thermal imaging Detector IR UFPA
Field Of View 17° x 17°
THT45• 80 x 80 Pixels• Thermal IR camera• PiP function• Automatic detection of hot and cold spots• Built-in laser pointer and illuminator• 3 Cursors: central, Min, Max• Data saved to JPEG and MPEG4
Power Source Lithium-Ion Rechargeable Battery, Battery Charger
Standard AccessoriesFocal lens 9mm,universal plugs, Micro SD card 8GB, USB cable, Video cable, Earphone set, Carry bag, Wrist strap, THTLink Windows software, Quick reference guide, User manual on CD-ROM
Certifiation ISO9000
Model Specification
Power Source 3 x AA IEC LR06 Batteries
Model Specification
THT60• 160 x 120 Pixels• Thermal infrared camera • Touch screen 3.5” TFT• Micro-SD card and USB interface to PC• 8 Standard + 10 custom colour palettes • Built in laser pointer and illuminator• PiP function• PAL/NTSC video out
1.0Thermal ImagersInstruments
85
Technical Overview
Field 0f View 24º x 32º
Spatial Resolution 3.05mrad
Thermal Sensitivity ≤ 0.08°C at 30°C
Detector Resolution 160 x 120° pixels
Temperature Range -20°C to 350°C
Focus Fixed
Image Mode IR , CCD
Visible Pixels High Definition CCD, 8 Mega Pixel
Colour Palettes 6 Standards (Iron INV, Rainbow, Feather, Grey and Grey INV))
Display 5.5” HD Capacitive touch screen LCD
File Format JPG
Measurement Functions4 moveable spots , Auto hot/cold spot identification, Isothermal analysis, circle analysis, rectangular analysis, line profile
Measurement Accuracy ±2ºC or ±2% of reading
IP Rating IP54
Shock/Vibrations 25G/2G
APPS Reporter Software Installed as Standard
TPK160• 160 x 120 Pixels• Thermal imager • Integrates tablet and thermal camera technology• Communicate in real time, live image and video transmission• WiFi/Bluetooth• GPS• Built in memory• 8MP CCD digital camera
Technical Overview
Temperature Range -20°C to 400°C
Thermal Sensitivity <0.08°C @ 30°C
Visual Range (FOV) 29.8° x 22.6° (lens 7.5mm)
Spectral Range 8 to 14µm
IR Resolution 160 x 120 pixels
Colour Palettes 8 Standard, 10 Custom Colours
Therman Image Sensitivity 80mK at 30°, 50Hz
Digital Zoom 1x to 20x
Save File Format JPEG, MPEG4
Integrated Photo Camera 60 x 480 pixels
Image Frequency 50Hz
Thermal Image Detector IR UFPA
Power Source 2 x 7.4V Lithium-Ion Rechargeable Batteries
Standard Accessories
7.5mm lens and protection cover, AC/DC adapter + universal plugs, Charger base, 4GB micro SD card and card reader, USB cable for PC connection, RCA video output cable, Rubber support for LCD hood, Rubber support for tripod, Earphone set, CD-ROM with THTLink software, User manual, Hard carry case
Optional Lenses RL1160-11mm, RL2260-22mm and RL3360-33mm
Certifiation ISO9000
Model Specification
Power Source Battery charger
Standard AccessoriesAC adaptor, USB cable, Headset, Wrist Strap, Software App (Installed on the unit), Hard Carrying Case, Operational Manual /Calibration Report
Model Specification