Rev. 9/2021 Installation & Operation Manual Willoughby Industries, Inc. 5105 West 78th Street Indianapolis, IN 46268 Toll Free: (800) 428-4065 Local: (317) 875-0830 Fax: (317) 875-0837 www.willoughby-ind.com MADE IN THE U.S.A. WAF-5403 Series WAF-5404 Series Aquafount ® 54" 180° Solid Surface Washfountain Electronic/Pneumatic Table of Contents Pre-Installation Information������������������������������������� 3 Physical Dimensions ���������������������������������������������� 4 Rough-In Dimensions ��������������������������������������������� 6 Required Installation Supplies �������������������������������� 9 Parts List��������������������������������������������������������������� 10 Exploded-view Drawing ���������������������������������������� 11 Hardware Identification Chart ������������������������������� 12 Installation Instructions ��������������������������������������������� Step 1: Pedestal Mounting������������������������������� 13 Step 2: Mounting Basin������������������������������������ 14 Step 3: Drain Assembly ����������������������������������� 15 Step 4A: Connections for Infrared/Piezo Actuators������������������������������������������� 16 Step 4B: Connections for Pneumatic Actuators ��������������������������������������������������������������������������17 Step 5: Final Assembly ������������������������������������ 18 JACO Fitting Instructions �������������������������������������� 19 Mixing Valve Instructions ��������������������������������������20 Infrared Sensor Installation Instructions ��������������� 21 Liquid Soap Specification and Maintenance��������� 22 Care and Maintenance ����������������������������������������� 23 Troubleshooting �������������������������������������������������������� Infrared Sensors ����������������������������������������������� 24 Electronic Valves ����������������������������������������������25 Pneumatic Valves ���������������������������������������������26 Replacement Part Numbers ��������������������������������� 27 Drawings������������������������������������������������������������������� General Dimensions ����������������������������������������� 28 Rough-in Dimensions ��������������������������������������� 30 Valve Details �����������������������������������������������������32 Miscellaneous Details ��������������������������������������� 41 Warranty ���������������������������������������������������������������45 * Wall mounted models only. Follow the applicable instructions in this manual to ensure installation complies with A.D.A. requirements. WAF-5404

Upload: others

Post on 17-Jul-2022

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Installation peration Manual - Willoughby Industries

Rev. 9/2021

Installation & Operation Manual

Willoughby Industries, Inc.5105 West 78th StreetIndianapolis, IN 46268Toll Free: (800) 428-4065Local: (317) 875-0830Fax: (317) 875-0837www.willoughby-ind.com MADE IN THE U.S.A.

WAF-5403 SeriesWAF-5404 Series

Aquafount® 54" 180° Solid Surface WashfountainElectronic/PneumaticTable of Contents

Pre-Installation Information �������������������������������������3Physical Dimensions ����������������������������������������������4Rough-In Dimensions ���������������������������������������������6Required Installation Supplies ��������������������������������9Parts List ���������������������������������������������������������������10Exploded-view Drawing ���������������������������������������� 11Hardware Identification Chart �������������������������������12Installation Instructions ���������������������������������������������

Step 1: Pedestal Mounting �������������������������������13Step 2: Mounting Basin ������������������������������������14Step 3: Drain Assembly �����������������������������������15Step 4A: Connections for Infrared/Piezo Actuators �������������������������������������������16Step 4B: Connections for Pneumatic Actuators ��������������������������������������������������������������������������17Step 5: Final Assembly ������������������������������������18

JACO Fitting Instructions ��������������������������������������19Mixing Valve Instructions ��������������������������������������20Infrared Sensor Installation Instructions ���������������21Liquid Soap Specification and Maintenance ���������22Care and Maintenance �����������������������������������������23Troubleshooting ��������������������������������������������������������

Infrared Sensors �����������������������������������������������24Electronic Valves ����������������������������������������������25Pneumatic Valves ���������������������������������������������26

Replacement Part Numbers ���������������������������������27Drawings �������������������������������������������������������������������

General Dimensions �����������������������������������������28Rough-in Dimensions ���������������������������������������30Valve Details �����������������������������������������������������32Miscellaneous Details ���������������������������������������41

Warranty ���������������������������������������������������������������45

* Wall mounted models only. Follow the applicable instructions in this manual to ensure installation complies with A.D.A. requirements.

WAF-5404

Page 2: Installation peration Manual - Willoughby Industries

Page 2Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

(Page intentionally left blank)

(Page intentionally left blank)

Page 3: Installation peration Manual - Willoughby Industries

Page 3Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Pre-Installation Information

When installing the Willoughby Industries' WAF-5403/5404 Series washfountain system:

Before Step 1 of the installation instructions, ensure that rough-ins are in the correct location�

The valve assembly, including the spray head, MUST NOT BE connected until afterall lines have been flushed to remove the small particles of debris that are inherentwith new construction projects and all chemicals that are used in flushing are purgedfrom the system�

Chemicals used in flushing plumbing systems can attack the internal components ofthe valve and spray head and severely damage them, so any flushing of the systemmust be followed by a full flushing with pure water to clear any harsh chemicalsremaining in the system� Debris in the system if allowed to enter the valve assemblyand spray head can cause poor performance or outright failure�

Again DO NOT attempt to connect the valve assembly and spray head until after allflushing is complete and pure water is the only media that will be passing through thesystem� Damage to the valve assembly or spray head caused by harsh chemicals ordebris will not be covered by the manufacturer's warranty�

INSTALLATION INSTRUCTIONS

Visit our website at http.//www.willoughby-ind.com2210 West Morris Street • P.O. Box 21217 • Indianapolis, IN 46221

(317) 638-2381 • Fax: (317) 638-6110 • (800) 428-4065© Rev. 11/2007 Page 3

Installation notice!Check Rough-in location and flush lines prior to hook up!

When installing the Willoughby Industries’ WAW, WAF, or WWF serieswashfountains or lavatory deck systems:

Before Step 1 of the installation instructions, ensure that rough-ins are in the correctlocation.

It is essential that the water supply lines be thoroughly flushed prior to making finalconnection to the hot and cold water supply lines. These lines must be flushedsufficiently to remove the small particles of debris that are inherent with newconstruction projects. If this debris is not removed, the valving in these units will bedamaged. Do not attempt to remove aerators to flush debris into the lavatory. Thedamage can only be fixed by replacing the valves. Damage to valves caused by debriswill not be covered by the manufacturers warranty.

Installation notice!Check Rough-in location and flush lines prior to hook up!

© Rev. 5/2010

INSTALLATION INSTRUCTIONS

Visit our website at http.//www.willoughby-ind.com2210 West Morris Street • P.O. Box 21217 • Indianapolis, IN 46221

(317) 638-2381 • Fax: (317) 638-6110 • (800) 428-4065© Rev. 11/2007 Page 3

Installation notice!Check Rough-in location and flush lines prior to hook up!

When installing the Willoughby Industries’ WAW, WAF, or WWF serieswashfountains or lavatory deck systems:

Before Step 1 of the installation instructions, ensure that rough-ins are in the correctlocation.

It is essential that the water supply lines be thoroughly flushed prior to making finalconnection to the hot and cold water supply lines. These lines must be flushedsufficiently to remove the small particles of debris that are inherent with newconstruction projects. If this debris is not removed, the valving in these units will bedamaged. Do not attempt to remove aerators to flush debris into the lavatory. Thedamage can only be fixed by replacing the valves. Damage to valves caused by debriswill not be covered by the manufacturers warranty.

Installation notice!Check Rough-in location and flush lines prior to hook up!

© Rev. 5/2010

Check Rough-In location PRIOR to installation

Flush lines thoroughly PRIOR to hook-up

Check Rough-In location PRIOR to installation

Flush lines thoroughly PRIOR to hook-up

Pre-Installation Information

Page 4: Installation peration Manual - Willoughby Industries

Page 4Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Physical Dimensions- Floor-mounted Unit *WAF-5403-FL unit shown; WAF-5404-FL will have same pedestal dimensions.

Physical Dimensions- Floor-mounted Unit

Page 5: Installation peration Manual - Willoughby Industries

Page 5Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Physical Dimensions- Wall-mounted Unit *WAF-5404 unit shown; WAF-5403 will have same pedestal dimensions.

Physical Dimensions- Wall-mounted Unit

Page 6: Installation peration Manual - Willoughby Industries

Page 6Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Rough-in Dimensions- Floor-mounted Unit *WAF-5403-FL unit shown; WAF-5404-FL will have same rough-in dimensions.

Rough-in Dimensions- Floor-mounted Unit

Page 7: Installation peration Manual - Willoughby Industries

Page 7Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

9-11/16"

17"

23-11/16" A.F.F.(FOR 34" A.D.A.

RIM HEIGHT)

NOTED

2 PLCS:

A5404-0026AS NOTED

1

Indianapolis, IndianaBEH

BEH 06-18-14

06-18-14AANGLE:

ASIZE:

54" SOLID SURFACE WASHFOUNTAIN - OFF FLOOR - 34" RIM HEIGHT

SHEET:REV.:

ORIG.:REVISION:

SCALE: 1:5FRACTIONS:EXCEPT AS

3 OF 3REF.:

TOLERANCES

TITLE / DESC.: WAF-5404 PART #:

MAT'L:3 PLCS:

0.030.0151/32"

Willoughby Industries, Inc.

STANDARD

RIM HEIGHT OF 34" AFF.

WATER SUPPLY

110V GFCI ELECTRICAL OUTLET

LOCATION OF THE 110 / 24 VAC

FINISHED FLOOR

CODES FOR THE MOUNTING CONSULT LOCAL ELECTRICAL

(EL1, IR ONLY)

FOR ALTERNATE RIM HEIGHT.ADJUST DIMENSIONS ACCORDINGLY

CLASS 2 TRANSFORMER

1/2" HOT AND COLD

NOTE:ROUGH-IN DIMENSIONS ARE FOR A

WALL MOUNTED ROUGH-IN SHOWN.FOR FLOOR MOUNTED ROUGH-IN, CONTACT FACTORY.

3-1/16"

5-9/16"

1-5/8"

12"

12-7/8"

7-13/16" 7-13/16"

26-1/2"

15-1/4"

4"

1-9/16"

4" 6" 11-1/4"

2-1/2"

20-3/8"

17X 5/16" THRU

7-3/4"

1-1/2" DRAIN 6-1/4"

15-3/8"

WILLOUGHBY

Rough-in Dimensions- Wall-mounted Unit *WAF-5404 unit shown; WAF-5403 will have same rough-in dimensions.

Rough-in Dimensions- Wall-mounted Unit

Page 8: Installation peration Manual - Willoughby Industries

Page 8Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

(Page intentionally left blank)

(Page intentionally left blank)

Page 9: Installation peration Manual - Willoughby Industries

Page 9Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Required Installation Supplies

• Proper mounting hardware

• Hardware for waste oulet connections

• Gasket for waste outlet connection

• Shims (for installation if necessary)

• Supply piping

• Silicone caulk

• Plumbers putty

WARNING: Willoughby Industries does not assume any responsibility for personal injury or damage to equipment due to an improperly installed WAF-5403/5404 Series washfountain.

Required Installation Supplies

Page 10: Installation peration Manual - Willoughby Industries

Page 10Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Parts List

*XX REPRESENTS THE WASH FOUNTAIN COLOR

WHITE GRANITE=WG SAND STONE=SS GRAY GRANITE=GG BLACK GRANITE=BG SEA GREEN=SG NOCTURNAL BLUE=NB GLACIER WHITE=GW BONE=B

ITEM #

DESCRIPTION PART NUMBER (P/N) - 3-STATION

PART NUMBER (P/N)- 4-STATION

1 54" HALF-ROUND BASIN - SOLID SURFACE 800540C-XX* 800540C-XX*

2PEDESTAL ASSEMBLY (WALL-MOUNT) WAF5404-WA WAF5404-WAPEDESTAL ASSEMBLY (FLOOR-MOUNT) WAF5404-FL WAF5404-FL

3

ACTUATOR HOUSING / VALVE HEAD KIT - INFRARED WAF5403-I WAF5404-IACTUATOR HOUSING / VALVE HEAD KIT - PIEZO WAF5403-E WAF5404-EACTUATOR HOUSING / VALVE HEAD KIT - PNEUMATIC WAF5403-P WAF5404-PACTUATOR HOUSING / VALVE HEAD KIT - BATTERY OPERATED WAF5403-B WAF5404-B

4STND� SPRAY HEAD ASSEMBLY- WAF(AERATOR SPRAY HEAD, 0.5 GPM- #320157A)(SPRAY HEAD BASE, 45*- #800001)

320157A-ASMB 320157A-ASMB

5 TOP COVER- SOLID SURFACE 800333LP-XX* 800441LP-XX*6 DRAIN ASSEMBLY (WAF) 380281 3802817 VALVE BRACKET ADAPTER (WAF) S600417 S600417

8ACCESS COVER (WALL-MOUNT) S600481 S600481ACCESS COVER (FLOOR-MOUNT) S600171 S600171

9-12 HARDWARE KIT 800258 800258

NO

T SH

OW

N

INFRARED SENSOR 700150 700150PIEZO PUSHBUTTON 701179-C 701179-CACTUATOR PUSHBUTTON 600307 600307ELECTRONIC VALVE ASSEMBLY 803105-3EL 803105-4ELPNEUMATIC VALVE ASSEMBLY 803105-3PW 803105-4PWBATTERY OPERATED VALVE ASSEMBLY 803150-3BW 803105-4BWCHECKSTOP ASSEMBLY 980183 980183STAINLESS STEEL FLEX HOSE (6") 980506 980506STAINLESS STEEL FLEX HOSE (20") 980520 980520POWERS HYDROGUARD T/P (LFe480) 700480ELF 700480ELFPOWER SUPPLY - INFRARED 800137B 800138BPOWER SUPPLY - PIEZO 800139A 800140APLUG-IN TRANSFORMER - INFRARED 701210 701210PLUG-IN TRANSFORMER - PIEZO 701210 701211PNEUTRONIC TIMER 330043 330043

Parts List

Page 11: Installation peration Manual - Willoughby Industries

Page 11Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Exploded-view Drawing

ITEM # PART # DESCRIPTION QTY.1 800540C-XX 54" HALF ROUND BASIN 12 S600476 PEDESTAL - WALL MOUNT - 34" RIM 13 S600196 4 STATION HEAD ASSEMBLY 1

4 320157A-ASMB STANDARD SPRAY HEAD ASS'Y FOR WASHFOUNTAINS, 0.5 GPM 4

5 800441LP-XX 4 STATION TOP COVER - SOLID SURFACE 16 380281 WASHFOUNTAIN DRAIN ASSEMBLY, 1-1/2" NPSM 17 S600417 VALVE BRACKET ADAPTER - WWF / WAF 18 S600481 ACCESS COVER 19 800144 1/4-20 X 1/2" PHILLIPS TRUSS HEAD SCREW 710 4500NSS 1/4-20 X 1/2" BUTTON HEAD SECURITY SCREW 1211 800127 1/4-20 X 1-1/2" FH SECURITY SCREW 212 800113 TINNERMAN NUT 1/4-20, S/S 6

NOTE:TO ORDER REPLACEMENT SOLID SURFACE PARTS, SPECIFY DESIRED COLOR BY REPLACING "XX" IN PART NUMBER WITH CORRESPONDING COLOR CODE:

B BONEBG BLACK GRANITEGG GREY GRANITEGW GLACIER WHITENB NOCTURNAL BLUERC RED CORALSG SEA GREENSS SANDSTONEWG WHITE GRANITE

1

3

12

12

4

11

5

10

8

2

7

6

9

10

2 PLCS: BEH

BEH 06-18-14

06-18-14A 2 OF 3

AS NOTED

A5404-0026Indianapolis, Indiana

1:14NOTED

ASIZE:

54" SOLID SURFACE WASHFOUNTAIN - OFF FLOOR - 34" RIM HEIGHT

SHEET:REV.:

ORIG.:REVISION:

SCALE: REF.:1

3 PLCS:

PART #:

MAT'L:

FRACTIONS:

TOLERANCES EXCEPT AS

WAF-5404TITLE / DESC.:

ANGLE:

0.030.0151/32"

Willoughby Industries, Inc.

STANDARD

WILLOUGHBY

*WAF-5404 (wall-mounted) unit shown

Exploded-view Drawing

Page 12: Installation peration Manual - Willoughby Industries

Page 12Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Hardware Identification ChartINSTALLATION INSTRUCTIONS

Visit our website at http.//www.willoughby-ind.com2210 West Morris Street • P.O. Box 21217 • Indianapolis, IN 46221

(317) 638-2381 • Fax: (317) 638-6110 • (800) 428-4065© Rev. 1/2007 Page 11

HARDWAREIdentification Chart

© Rev. 5/2010

Hardware Identification Chart

Page 13: Installation peration Manual - Willoughby Industries

Page 13Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Parts supplied:

• Complete Unit (Pre-assembled)

Note: Hardware for wall anchoring by others.

Note: Use anchors that are adequate for the type of wall: drywall, concrete, metal studs, wood studs, etc.

Note: Refer to rough-in drawing for backplate mounting hole locations to achieve 34" rim height.

1�) Measure and mark the vertical centerline of the washfountain on the wall. Mark a level line at the height prescribed by the rough-in drawing for the pedestal backplate center hole. Drill a hole for a wall anchor (supplied by others) at this height mark. Make sure that the intended anchor locations will provide adequate backing to support the installed washfountain. If adequate backing does not exist, install appropriate support backing or relocate unit before proceeding with installation (backing provided by others).

2�) Mount the pedestal on the wall using a wall anchor through the backplate center hole and the first drilled hole. DO NOT TIGHTEN THIS FIRST WALL ANCHOR ALL THE WAY, as you may need to adjust the pedestal to ensure it is level�

3�) Make sure the pedestal is level and plumb against the wall, then mark and drill holes for the rest of the wall anchors as specified by the rough-in drawing.

4�) Ensure once more the pedestal is level, then secure it to the wall using the remaining anchors (supplied by others). Make sure all wall anchors are tight and secure against the pedestal backplate.

Note: Be sure backplate is level and plumb against the wall so that water in basin will drain correctly once assembly is completed.

Installation Instructions

PEDESTAL BACKPLATE

PEDESTAL BACKPLATECENTER HOLE

VALVE MOUNTING TAB

WALL ANCHORS(SUPPLIED BY OTHERS)

NOTE: FOR CLARITY OF WALL ANCHOR MOUNTING LOCATIONS, ONLY THE BACKPLATE PORTION OF THE PEDESTAL IS SHOWN.

Step 1: Pedestal Mounting

Installation Instructions

Page 14: Installation peration Manual - Willoughby Industries

Page 14Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Installation Instructions (cont.)

SECURITY SCREWS

SHIPPING BOLTS

ACTUATOR HOUSING

BASIN

(SUPPLIED BY OTHERS)WALL ANCHORS

PEDESTAL

1/4-20 X 1/2" PHILLIPS TRUSS HEAD SCREWS

TOP LEDGE

Step 2: Mounting BasinParts supplied:

• Solid Surface Basin

• Actuator Housing

• Pedestal Backplate

Removing the top cover. Mounting the basin and actuator housing to the backplate and wall.

1�) Remove top cover from the valve head kit by loosening the security screws as shown in the above-left diagram� Set the top cover, screws, and nuts aside�

2�) With the help of an assistant, place basin on top ledge of the pedestal assembly�

3�) Carefully mark mounting holes on wall through the basin, then remove the basin and drill the mounting holes�

4�) Replace the basin and valve head kit as shown in the above-right diagram.

5�) Fasten wall anchors (supplied by others) through the basin and valve head kit holes securely, but DO NOT OVERTIGHTEN; this can damage the solid surface basin and valve head kit.

6�) Secure the basin to the pedestal by fastening the1/4-20 x 1/2" Philips truss head screws up through the pedestal basin mounting ring into the threaded inserts on the bottom of the basin�

Note: BE SURE to use the truss head screws included with the washfountain. Using longer screws than those provided can damage the solid surface basin.

Installation Instructions

Page 15: Installation peration Manual - Willoughby Industries

Page 15Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Installation Instructions (cont.)Step 3: Drain AssemblyParts/Materials supplied:

• Solid surface basin

• Drain assembly (see diagram)

• Plumbers putty (supplied by others)

1�) As shown on the diagram, apply a small (approx� 1/4" dia. 6" long) strand of plumbers putty on the underside of the drain basket lip (putty supplied by others)� 2.) Insert the drain basket down through the basin drain hole�

3.) Secure the drain basket in place by fitting the rubber and stainless steel washers onto the drain assembly from the underside of the basin� Tighten the locknut onto the drain basket assembly, sandwiching the washers between the basin and locknut.

Note: Over-tightening the locknut or security screw can damage the solid surface basin and/or drain assembly components.

4.) Secure the drain cover to the drain basket using the provided screw�

WASHERS

Installation Instructions

Page 16: Installation peration Manual - Willoughby Industries

Page 16Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Installation Instructions (cont.)

Parts supplied:

• Valve Assembly (pre-installed)

• 3/8" x 4' Multi-Colored Water Lines

• Small Diameter Multi-Colored Pneumatic Tubing

• 1/4-20 x 1/2" security screws

• 1/4-20 tinnerman nuts

Note: Use wire tie mounts and wire ties to route and secure wiring. Wires are long enough to accommodate various routing paths. Longer tubes may need to be bundled with wire ties so they do not come in contact with sharp corners.

INSTALLATION INSTRUCTIONS

Visit our website at http.//www.willoughby-ind.com2210 West Morris Street • P.O. Box 21217 • Indianapolis, IN 46221

(317) 638-2381 • Fax: (317) 638-6110 • (800) 428-4065© Rev. 1/2007 Page 6

Parts supplied:

· Valve AssemblyPlug-In TransformerTerminal Block Plate4’ x 3/8" multi-colored water lines

· ¼-20 x ½” security screws· ¼-20 tinnerman nuts· Wire ties· Wire tie mounts (adhesive backed)

1.) Locate terminal block plate and attach to pedestal using ¼-20 x ½” security screws and tinnerman nuts.

2.) Locate the group of loose colored wires coming from the terminal block plate labeled “UPPER”.3.) Feed two like-colored wires into each of the actuator housing assembles.

Note: Use wire tie mounts and wire ties to route and secure wiring. Wires are long enough toaccommodate various routing paths. Longer wires may need to be bundled with wire ties so thatthey do not come in contact with sharp corners.

4.) Plug both like-colored wires into the actuator as shown above (either wire will work on eachconnector).

5.) Locate the 3/8" x 4’ colored tubing water lines. Match up the color of tubing with the color of wireand run the tubing into each of the actuator housings. Loosen the plastic nut and firmly push thetubing into the elbow connector located in each spray head. Tighten nut securely. Repeat foreach spray head, being sure to match each of the colors together (wire and tubing).

6.) Connect each set of like-colored wires and tubing to each of the manifolded valves.

STEP FOUR-AConnections for Infrared / Piezo Actuators

Infrared

Piezo

© Rev. 5/2010

Piezo Push Button Actuator

INSTALLATION INSTRUCTIONS

Visit our website at http.//www.willoughby-ind.com2210 West Morris Street • P.O. Box 21217 • Indianapolis, IN 46221

(317) 638-2381 • Fax: (317) 638-6110 • (800) 428-4065© Rev. 1/2007 Page 6

Parts supplied:

· Valve AssemblyPlug-In TransformerTerminal Block Plate4’ x 3/8" multi-colored water lines

· ¼-20 x ½” security screws· ¼-20 tinnerman nuts· Wire ties· Wire tie mounts (adhesive backed)

1.) Locate terminal block plate and attach to pedestal using ¼-20 x ½” security screws and tinnerman nuts.

2.) Locate the group of loose colored wires coming from the terminal block plate labeled “UPPER”.3.) Feed two like-colored wires into each of the actuator housing assembles.

Note: Use wire tie mounts and wire ties to route and secure wiring. Wires are long enough toaccommodate various routing paths. Longer wires may need to be bundled with wire ties so thatthey do not come in contact with sharp corners.

4.) Plug both like-colored wires into the actuator as shown above (either wire will work on eachconnector).

5.) Locate the 3/8" x 4’ colored tubing water lines. Match up the color of tubing with the color of wireand run the tubing into each of the actuator housings. Loosen the plastic nut and firmly push thetubing into the elbow connector located in each spray head. Tighten nut securely. Repeat foreach spray head, being sure to match each of the colors together (wire and tubing).

6.) Connect each set of like-colored wires and tubing to each of the manifolded valves.

STEP FOUR-AConnections for Infrared / Piezo Actuators

Infrared

Piezo

© Rev. 5/2010

Infrared Sensor Actuator

1.) Locate the terminal block plate and attach to the pedestal using 1/4-20 x 1/2" security screws and tinnerman nuts�

2.) Locate the group of loose colored wires coming from the terminal block plate labeled "UPPER".

3.) Feed 2 like-colored wires into each of the actuator housing assemblies (either the Infrared or Piezo assemblies, whichever applies to the installation).

4.) Plug both like-colored wires into the actuator as shown above (either wire will work on each connector)�

5.) Locate the 3/8" multi-colored water lines. Match the color of each water line with the corresponding color of wiring� Run the end of each water line up through the basin to the head kit. Match the color of each water line to the spray head assembly below each actuator. On each corresponding spray head, loosen the plastic nut on the plastic connector and firmly push the water line through the plastic nut into the fitting. Tighten the plastic nut to secure the water line to the spray head. Repeat for each remaining water line. (**see JACO Fitting Instructions on Page 19 for further detail)� 6.) Once all water lines have been attached to their corresponding spray heads, on each corresponding manifolded valve assembly, loosen the plastic nut on the plastic connector and firmly push the water line through the plastic nut into the fitting. Tighten plastic nut to secure the water line to the valve assembly� Repeat for each water line�

7.) Connect each set of like-colored wires to each of the manifolded valves.

Step 4A: Connections for Infrared/Piezo Actuators

Installation Instructions

Page 17: Installation peration Manual - Willoughby Industries

Page 17Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Installation Instructions (cont.)Step 4B: Connections for Pneumatic ActuatorsParts supplied:

• Valve Assembly (pre-installed)

• 3/8” x 4’ Multi-Colored Water Lines

• Small Diameter Multi-Colored Pneumatic Tubing

• 1/4-20 x 1/2" security screws

• 1/4-20 tinnerman nuts

Note: Use wire tie mounts and wire ties to route and secure tubing. Longer tubes may need to be bundled with wire ties so that do not come in contact with sharp corners.

1�) Locate the small multi-colored pneumatic tubing� Feed each one into each of the actuator housing assemblies�

2.) Plug each tube onto the hose barb on the back of the push button.

3.) Locate the 3/8" multi-colored water lines. Match the color of each water line with the corresponding color of tubing� Run the end of each water line up through the basin to the head kit. Match the color of each water line to the spray head assembly below each push button actuator. On each corresponding spray head, loosen the plastic nut on the plastic connector and firmly push the water line through the plastic nut into the fitting. Tighten the plastic nut to secure the water line to the spray head. Repeat for each remaining water line. (**see JACO Fitting Instructions on Page 19 for further detail)� 4.) Once all water lines have been attached to their corresponding spray heads, on each corresponding manifolded valve assembly, loosen the plastic nut on the plastic connector and firmly push the water line through the plastic nut into the fitting. Tighten plastic nut to secure the water line to the valve assembly� Repeat for each water line�

5.) Connect each set of like-colored tubing to each of manifolded valves.

Pneumatic Push Button (Similar 3-station unit shown)

Installation Instructions

Page 18: Installation peration Manual - Willoughby Industries

Page 18Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Step 5: Final AssemblyParts supplied:

• Solid Surface Top Cover

• Access Cover

• 1/4-20 Tinnerman Nut

• 1/4-20 x 1" Security Screw

• 1/4-20 x 1-1/2" Flat Head Security Screws

1�) Make all final plumbing connections to valve inlets using supplied flex hoses (flex hoses have shut-off valves attached that should be connected to the supply inlets).

2�) Once all of the connections in the actuator housings are complete, locate the transformer. NOTE: PLUG-IN TRANSFORMER (IF NEEDED) MUST BE USED WITH A GROUND FAULT INTERRUPT (GFCI) RECEPTACLE TO HELP PREVENT POSSIBLE ELECTRICAL SHOCK.

3�) Test the system for leaks (both supply and waste).

4�) Using 1/4-20 x 1-1/2" flat head security screws, attach top cover to the actuator housing.

5�) Using 1/4-20 x 1" security screws, attach shroud to the backplate.

Installation Instructions (cont.)

TOP COVER

1/4-20 X 1-1/2" FLAT HEAD SECURITY SCREW

1/4-20 X 1/2" SECURITY SCREW

ACCESS COVER

Installation Instructions

Page 19: Installation peration Manual - Willoughby Industries

Page 19Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

INSTALLATION INSTRUCTIONS

Visit our website at http.//www.willoughby-ind.com2210 West Morris Street • P.O. Box 21217 • Indianapolis, IN 46221

(317) 638-2381 • Fax: (317) 638-6110 • (800) 428-4065© Rev. 11/2006

Note: It is not necessary to disassemble this fitting for application. Merely insert tubing to stop andtighten seal.

1. Cut tubing end squarely and remove the internal burrs.2. Insert the tubing through the back of the nut all the way through the nut assembly to the tube stopin the fitting body (see illustration). If the tubing does not enter the nut easily, loosen the nut one turnand reinsert the tubing all the way to the tube stop in the fitting body.3. Turn the nut hand tight.4. Wrench tighten the nut 1½ - 2 turns.5. All nuts must be retightened when the system reaches projected operating temperature.

Note: To ensure proper assembly, tubing MUST be fully inserted into the fitting body all the way tothe tube stop.Note: Squeaking sound when tightening nut is normal. For pipe threaded connections, Teflon tapemust be used.

JACO FittingInstructions

JACO Fitting Instructions

JACO Fitting Instructions

Page 20: Installation peration Manual - Willoughby Industries

Page 20Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Mixing Valve Instructions INSTALLATION INSTRUCTIONS

Visit our website at http.//www.willoughby-ind.com2210 West Morris Street • P.O. Box 21217 • Indianapolis, IN 46221

(317) 638-2381 • Fax: (317) 638-6110 • (800) 428-4065© Rev. 11/2007 Page 15

To Install

NOTE: Installation should be in accordance with accepted plumbing practices. Flush all piping thoroughly before installa-tion.1. Locate a suitable place for the tempering valve. Valve should

be accessible for service and adjustment and as close to the point-of-use as possible.

2. Connect hot and cold water to the supply valve using 1/2” NPT or 3/8” compression connections.

3. Connect outlet of tempering valve to fi xture(s) using 1/2”NPT or 3/8” compression connections.

4. Turn on hot and cold water supplies. If any leaks are observed, tighten connections as necessary to stop leaks before proceeding.

5. Turn on fi xture and allow water to fl ow for 2 minutes.Measure water temperature at outlet. If water is not at desired temperature, adjust as necessary.

Specifi cations

e480-00 .......................................................1/2" NPT (Rough Bronze)e480-01 .................................................... 1/2" NPT (Rough Chrome)e480-10 ...................................... 3/8"Compression (Rough Bronze)e480-11 ..................................... 3/8"Compression (Rough Chrome)Capacity: ................................................................. 4.0 gpm (15.0 l/m)Approach Temperature: ..........................5°F (2.8°C) above set pt.Max. Operating Pressure: ......................................125psi (862 kpa)Max. Static Pressure: .............................................125psi (862 kpa)Max. Hot Water Temperature: ....................................180°F (82°C)Temp. Adjustment Range: ............................................ ASSE Type T/P: 95 – 110°F (43-48°C) ................................................. ASSE Type T: 80 – 120°F (27-49°C)Minimum Flow: ........................................................ 0.5 gpm (2.2 l/m)Checks: ......................................................................................IntegralConstruction: ........................................................... Cast Brass BodyCertifi ed: ................................................................................CSA B125Listing .....................................................ASSE 1016-1996 (Type T/P) .............................................................................................ASSE 1070

To Adjust Temperature

1. Loosen locknut.2. Turn on fi xture and run water for at least two (2) minutes

to allow supply temperature to stabilize.3. Turn temperature stem counter-clockwise for hotter or

clockwise for colder outlet temperature.4. Tighten locknut to prevent accidental or unauthorized

temperature adjustment.5. Re-check outlet temperature.

Repair Kit

Motor Repair Kit ........................................................................480-270

HydroGuard® T/P Series e480Lavatory Combination Valve

Installation Instructions

IS-P-e480

Figure 1

Figure 2: Typical Installation

Outlet

Hot WaterInlet

Temperature Adjustment Stem

Locknut Cold WaterInlet

Advanced Thermal Activation

© Rev. 5/2010

Mixing Valve Instructions

Page 21: Installation peration Manual - Willoughby Industries

Page 21Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Infrared Sensor Installation Instructions

INSTALLATION ANDOPERATION MANUAL

TOLL FREE (800) 428-4065 / LOCAL (317) 875-0830 / FAX (317) 875-0837

PAGE 1© Rev. 9/2016 www.willoughby-ind.com

WILLOUGHBY Industries, Inc. 5105 WEST 78TH STREET / INDIANAPOLIS, IN 46268

WILLOUGHBY INDUSTRIESINFRARED LAVATORY SENSOR

DETECTION AND ACTIVATION• When the sensor detects a user, a slow

ashing red light appears in the sensor window.

• After 1 to 2 seconds of detection, the light ashes rapidly and the sensor immediately activates the solenoid valve to begin water ow.

• The solenoid valve remains open as long as the user is detected.

• The solenoid valve turns off when the user is no longer detected.

• The sensor is set to activate the solenoid for a maximum of 30 seconds before automati-cally shutting off.

• Note: sensor range is factory preset to 20".Optional range adjustment remote avail-able to adjust range from 1"min to 30"max.

INSTALLATION AND REPLACEMENT1. Disconnect 24V AC power at the transformer

or fuse box.2. Remove top cover to expose sensors.3. Install new sensor. Make sure sensor arrow is

pointing up. See Figure 1.4. Connect the red male power cable to the

red female connector on the sensor.See Figure 3.

5. Connect the black female solenoid cable to the black male connector on the sensor.See Figure 3.

6. Replace top cover removed in Step 2.7. Reconnect power.

PART#: 70015024V AC System IR Sensor

FIGURE 3- 24V AC SYSTEM IR ASSEMBLY

FIGURE 1- IR SENSOR

FIGURE 2- IR REMOTE

Infrared Sensor Installation Instructions

Page 22: Installation peration Manual - Willoughby Industries

Page 22Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

(For models with “LSD” option only)

Liquid soap viscosity is measured in “cps” (centipoise). The liquid soap chosen to be used with Willoughby’s Liquid Soap Dispenser should be between 100cp and 2500cp.The viscosity of the soap should be thin and free flowing.Some soap types are available in a concentrate and must be diluted with water.

The pH (acidity) level should be in the range of 6.5 to 8.5.Soap which is too acidic (pH less than 6.5) can corrode stainless steel and degrade rubber, plastic, or chrome-plated materials.Soap that is outside the range of 6.5 - 8.5 might be harsh on the hands or skin.

(Generally, any quality soap meeting the viscosity and pH guidelines should work well.)

Recommended Maintenance Schedule

To maintain proper function, Willoughby’s Liquid Soap Dispenser should be cleaned periodically to remove soap residue. The Liquid Soap Spout should be soaked in hot water for a period of 30 minutes when cleaning is being performed. The soap tray should also be cleaned with hot water.

Liquid Soap Specification and Maintenance

Liquid Soap Specification and Maintenance

Page 23: Installation peration Manual - Willoughby Industries

Page 23Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Care and MaintenanceSolid Surface Care

Aquasurf® surfaces may be easily cleaned using conventional cleaning agents such as an ammonia based liquid cleaner, (glass cleaner).

Dry stains on a matte finish can be removed with a 3M Scotch-Brite gray scouring pad or a mild abrasive cleaner.

Burns or scorches can be removed by sanding with coarse grit sandpaper followed by finer grit (220) sandpaper. Follow sanding with a 3M Scotch-Brite gray pad (or equivalent) to match finish of sanding area to surrounding area. A final buffing may be required on polished surfaces. Accidental nicks or chips can be repaired with special patch kits available in all Aquasurf® colors.

Avoid exposing Aquasurf® surfaces to strong chemicals such as acetone’s; paint removers and sulfuric acid or hydrochloric chemical cleaners. Exposure to strong chemicals may result in permanent damage to Aquasurf® surfaces.

Stainless Steel Care

Stainless Steels are basically alloys of iron and chromium and are corrosion resistant. Stainless steel has a bright surface that is easy to clean and is free from oxides. Therefore, cleaning of stainless steel is relatively simple and easy if done on a regular basis.

Frequency of cleaning should depend on the rate at which the fixture becomes dirty. Remember that fresh (soft) deposits of all kinds are relatively easy to remove, while removing older (hard) deposits are much more difficult. Establish a cleaning SCHEDULE.

Routine cleaning should involve ordinary soap or detergent and water, applied with a sponge, brush or cloth. Baking soda, borax or any of several non-abrasive commercial cleansing agents can help hasten the cleaning action. After scrubbing, rinse THOROUGHLY and wipe dry.

DO NOT use common steel wool, scouring pads, scrapers, wire brushes, files or other steel tools to clean stainless steel. Such items will scratch the surface or leave small particles of iron imbedded in the surface, which will eventually rust and stain the surface - even appearing as if the stainless itself was rusting.

Certain chemical compounds, if used on stainless steel, can give the appearance of rust and if allowed to stand for long periods of time, can pit the surface of even stainless. Products containing hydrochloric acid, muriatic acid or potassium hydrochloride can ruin the surface.

Care and Maintenance

Page 24: Installation peration Manual - Willoughby Industries

Page 24Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Troubleshooting - Infrared SensorsI� Faucet does not function (red light does not appear when user steps in front of sensor)

A� No power to sensor. Make certain that power is on. Check transformer leads and connections. Repair or replace as necessary�

B� Willoughby 700150 IR Sensor not operating� Replace Willoughby 700150 IR Sensor�

II� Faucet does not function (red light appears when user steps in front of sensor and solenoid does not click)A� Debris in solenoid; disassemble, clean, and flush�B� Solenoid not wired correctly; check solenoid connections.C. Solenoid problem; replace solenoid�

III� No water when activated (valve clicks)A� Make certain that water is turned on.B� Valve clogged. Clean or replace filter.

IV� Very low flow or slow dribbleA� Check supply stop(s); open if closed.B� Debris in filter; remove, clean, and reinstall�C. Debris in aerator or spray head; remove, clean and reinstall�D� Disassemble solenoid; clean and flush�

V� Continues to run (with power on and red light flashing)A� Non-permanent target in range after user leaves� Remove non-permanent target� If this

target is a new permanent target (i�e�, a new wall or partition), turn off 24 volt power forfifteen (15) seconds. Turn power back on and let the sensor complete start-up mode�

B� Sensor failure; replace sensor�

VI� Continues to run (even with power disconnected)A� Solenoid valve installed backwards.B� Debris in solenoid, won’t close properly; remove operator and clean� Reassemble in the

same manner� 

Troubleshooting - Infrared Sensors

Page 25: Installation peration Manual - Willoughby Industries

Page 25Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

The two most common reasons an electronic valve does not operate properly are: (1) lack of power or (2) lack of water pressure. The following steps should be used as a guide in identifying the problem of a malfunctioning electronic valve.

I. Lack of powerA. Verify that the 110V GFCI outlet has powerB. Check all connections to ensure they have been made correctly:

1. Cable connecting the valve coil and the timer or IR sensor2. Cable connecting the timer and the pushbutton (Piezo only)3. Cable connecting the timing device and the 24VAC transformer4. The 24VAC transformer and the 110V GFCI outlet

C. If the valve is wired correctly, the solenoid will make a “click” sound indicating that the valve has been actuated. The electronic valve is actuated by either the piezo pushbutton or the triggering of the infrared sensor (see the Start-Up Instructions for Infrared Sensors in this manual).

II. Lack of water pressureA. Check the supply to the rough-insB. Make sure the screwdriver stops are in the open positionC. Water pressure needs to be above 35psi to operate the valve

1. If the water supply pressure is above 35psi but not exiting the valve:a. Clean any debris from the screen on the inlet side of the solenoid valve bodyb. Remove the screws on the valve body and clean any debris from the diaphragm

After all of the above steps have been followed, if there is still no water coming out of the spray head, there may be a damaged or defective part (see installation notice in the beginning of this manual).

Troubleshooting - Electronic Valves

Troubleshooting - Electronic Valves

Page 26: Installation peration Manual - Willoughby Industries

Page 26Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

I. Valve will not open or deliver waterA. Check the plastic tubing that runs from the pushbutton actuator to the pneumatic valve for

air leaks.B. Make sure the checkstop on the supply to the valve is fully open. Do not partially close the

checkstop for any reason as it is not a throttling valve. The checkstop should be fully open (normal operation) or fully closed (when servicing the valve).

C. Close checkstop and then inspect the strainer in the supply line (installed after the checkstop) to make sure the strainer is not blocked or partially blocked, prohibiting water flow.

II. Valve will not shut offA. Separate valve motor from casting by removing the four (4) #8 screws.B. Inspect the water diaphragm assembly to see if bypass hole in diaphragm is blocked.

Remove any debris by blowing on diaphragm or using force of air. Do not use any tool (such as straight pin) to remove any debris. Enlarging the hole will shorten or make for erratic cycling.

C. Check the metering screw on the timer assembly to make sure the adjustment screw is not closed too tightly. To reset, back out adjustment screw (counterclockwise) about 1-1/2” turns, and adjust for the desired cycle.

III. Valve continues to trickle or partially deliver water after cycle is overA. Inspect seating area on valve base to make sure no debris, pitting, or scoring is present.B. Clean seat or replace seat as necessary.C. Inspect seating area of diaphragm for debris, clean as necessary. If debris has caused

permanent indentations in the rubber, it may have to be replaced.

After all of the above steps have been followed, if there is still no water coming out of the spray head, there may be a damaged or defective part (see installation notice in the beginning of this manual).

Troubleshooting - Pneumatic Valves

Troubleshooting - Pneumatic Valves

Page 27: Installation peration Manual - Willoughby Industries

Page 27Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

Replacement Part Numbers*XX REPRESENTS THE WASH FOUNTAIN COLOR

B = BONE BG = BLACK GRANITEGG = GREY GRANITEGW = GLACIER WHITENB = NOCTURNAL BLUERC = RED CORALSG = SEA GREENSS = SAND STONEWG = WHITE GRANITE

Table 1 – Replacement part numbers for general assembly:

PART #DESCRIPTION WAF-5403 WAF-5404

SOLID SURFACE BASIN 800540C-XX*SOLID SURFACE TOP COVER 800333LP-XX* 800441LP-XX*PEDESTAL ASSEMBLY - WALL MOUNT WAF5404-WAPEDESTAL ASSEMBLY - ON FLOOR WAF5404-FLHARDWARE KIT 800258STND� SPRAY HEAD ASSEMBLY- WAF(AERATOR SPRAY HEAD, 0.5 GPM- #320157A)(SPRAY HEAD BASE, 45*- #800001)

320157A-ASMB

Table 2 – Replacement part numbers for models with Infrared Actuation:

PART #DESCRIPTION WAF-5403 WAF-5404

VALVE HEAD KIT - INFRARED WAF5403-I WAF5404-IVALVE ASSEMBLY - ELECTRONIC 803105-3EW 803105-4EWPOWER SUPPLY 800137B 800138BPLUG-IN TRANSFORMER 701210INFRARED SENSOR 700150

Table 3 – Replacement part numbers for models with Piezo Actuation:

PART #DESCRIPTION WAF-5403 WAF-5404

VALVE HEAD KIT - PIEZO WAF5403-E WAF5404-EVALVE ASSEMBLY - ELECTRONIC 803105-3EW 803105-4EWPUSHBUTTON - PIEZO 701179-CPOWER SUPPLY 800139A 800140APLUG-IN TRANSFORMER 701210 701211PNEUTRONIC TIMER 330043

Table 4 – Replacement part numbers for models with Pneumatic Actuation:

PART #DESCRIPTION WAF-5403 WAF-5404

VALVE HEAD KIT - PNEUMATIC WAF5403-P WAF5404-PVALVE ASSEMBLY - PNEUMATIC 803105-3PW 803105-4PWPUSHBUTTON - PNEUMATIC 600307

Replacement Part Numbers

Page 28: Installation peration Manual - Willoughby Industries

Page 28Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

DR

AWIN

G:

Gen

eral

Dim

ensi

ons

Replacement Part Numbers

Page 29: Installation peration Manual - Willoughby Industries

Page 29Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

IN C

OM

PLI

AN

CE

WIT

H A

.D.A

. 201

0

54"

28-

5/8"

FIN

ISH

ED

FLO

OR

26-1

/2"

BO

WL

DE

PTH

9-1

1/16

"

8-1/

4"

16-

1/16

"

FIN

ISH

ED

FLO

OR

FOR

A.D

.A.

34"

MA

X A

.F.F

.

5-5

/8"

AS N

OTE

D

1

PA

RT

#:W

AF-

5404

BE

HE

XC

EP

T A

S

3 P

LCS

:

AN

GLE

:

A54

04-0

026

NO

TED

2 P

LCS

:

1 O

F 3

SC

ALE

:R

EF.

:

MA

T'L:

TITL

E / D

ESC

.:

TOLE

RAN

CES

FRAC

TIO

NS:

ASI

ZE:

1:16

REV

ISIO

N:

AB

EH

54" S

OLI

D S

UR

FAC

E W

AS

HFO

UN

TAIN

- O

FF F

LOO

R -

34" R

IM H

EIG

HT

OR

IG.:

REV

.:06

-18-

14

Indi

anap

olis

, Ind

iana

SH

EE

T:

06-1

8-14

0.03

0.01

51/

32"

Will

ough

by In

dust

ries

, Inc

.

STAN

DAR

D

WIL

LOU

GH

BY

DR

AWIN

G:

Gen

eral

Dim

ensi

ons

Replacement Part Numbers

Page 30: Installation peration Manual - Willoughby Industries

Page 30Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

DR

AWIN

G:

Rou

gh-in

Dim

ensi

ons

DET

AIL

: DW

G#

P139

008A

Replacement Part Numbers

Page 31: Installation peration Manual - Willoughby Industries

Page 31Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

9-1

1/16

"

17"

23-1

1/16

" A.F

.F.

(FO

R 3

4" A

.D.A

.R

IM H

EIG

HT)

NO

TED

2 P

LCS

:

A54

04-0

026

AS N

OTE

D

1

Indi

anap

olis

, Ind

iana

BE

H

BE

H06

-18-

14

06-1

8-14

AA

NG

LE:

ASI

ZE:

54" S

OLI

D S

UR

FAC

E W

AS

HFO

UN

TAIN

- O

FF F

LOO

R -

34" R

IM H

EIG

HT

SH

EE

T:R

EV.:

OR

IG.:

REV

ISIO

N:

SC

ALE

:1:

5FR

ACTI

ON

S:E

XC

EP

T A

S

3 O

F 3

RE

F.:

TOLE

RAN

CES

TITL

E / D

ESC

.:W

AF-

5404

PA

RT

#:

MA

T'L:

3 P

LCS

:0.

030.

015

1/32

"

Will

ough

by In

dust

ries

, Inc

.

STAN

DAR

D

RIM

HE

IGH

T O

F 34

" AFF

.

WA

TER

SU

PP

LY

110V

GFC

I ELE

CTR

ICA

L O

UTL

ET

LOC

ATI

ON

OF

THE

110

/ 24

VA

C

FIN

ISH

ED

FLO

OR

CO

DE

S F

OR

TH

E M

OU

NTI

NG

C

ON

SU

LT L

OC

AL

ELE

CTR

ICA

L (E

L1, I

R O

NLY

)

FOR

ALT

ER

NA

TE R

IM H

EIG

HT.

AD

JUS

T D

IME

NS

ION

S A

CC

OR

DIN

GLY

CLA

SS

2 T

RA

NS

FOR

ME

R

1/

2" H

OT

AN

D C

OLD

NO

TE:

RO

UG

H-IN

DIM

EN

SIO

NS

AR

E F

OR

A

WA

LL M

OU

NTE

D R

OU

GH

-IN S

HO

WN

.FO

R F

LOO

R M

OU

NTE

D R

OU

GH

-IN,

CO

NTA

CT

FAC

TOR

Y.

3-1

/16"

5-9

/16"

1-5

/8"

12"

12-

7/8"

7-1

3/16

" 7

-13/

16"

26-

1/2"

15-

1/4"

4"

1-9

/16"

4"

6"

11-

1/4"

2-1

/2"

20-

3/8"

17X

5

/16"

TH

RU

7-3

/4"

1-1/

2" D

RA

IN

6

-1/4

"

15-

3/8"

WIL

LOU

GH

BY

DR

AWIN

G:

Rou

gh-in

Dim

ensi

ons

Replacement Part Numbers

Page 32: Installation peration Manual - Willoughby Industries

Page 32Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

7

4

8

1

2

3

5

9

10

11

6

NO

TE:

PAR

T #1

2 FL

EXH

OSE

, 20"

NO

T SH

OW

N

2 Pl

aces

+/-

.03

3 Pl

aces

+/-

.015

Frac

tions

+/-

1/32

"

Will

ough

by In

dust

ries

Inc.

Indi

anap

olis

, Ind

iana

Tole

ranc

esEx

cept

as

Title

or P

art D

escr

iptio

n:

Mat

eria

l:D

raw

n By

:D

ate:

Rev

isio

n #:

Dra

win

g #: Ap

prov

ed B

y:

VALV

E AS

SY, W

ASH

FOU

NT

3-ST

ATIO

N (E

L)

TRB

11/7

/11

B

8031

05-3

EW

Job

Nam

e:Pa

rt N

umbe

r:N

/A

Scal

e:1:

8Q

ty:

Shee

t:1

Of 1

N/A

Not

edAn

gle

+/- 1

ITEM

NO

.PA

RT

#D

ESC

RIP

TIO

NQ

TY.

170

0480

E P

ower

s 48

0E M

ixin

g Va

lve

12

9805

06FL

EXH

OSE

, 6"

13

8001

33#1

0-16

SEL

F TA

P TY

PE B

HEX

HEA

D S

CR

EW8

498

0183

CH

ECKS

TOP

ASSE

MBL

Y1

598

0501

3PM

1-M

A3 V

alve

Bra

cket

- Pl

astic

16

9801

64O

-RIN

G, #

015

4

798

0408

E1L

VALV

E AS

SEM

BLY

2

898

0197

PLAS

TIC

VAL

VE C

OU

PLIN

G2

998

0600

AVA

LVE

FITT

ING

ASS

EMBL

Y, 3

/8" E

LBO

W3

1098

0140

SPR

ING

CLI

P8

1198

0408

PRE1

L VA

LVE

ASSE

MBL

Y, R

IGH

T - P

LUG

GED

PO

RT

112

9805

20FL

EXH

OSE

, 20"

(NO

T SH

OW

N)

2

WIL

LOU

GH

BY

DR

AWIN

G:

Elec

tron

ic V

alve

Det

ail

Replacement Part Numbers

Page 33: Installation peration Manual - Willoughby Industries

Page 33Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

2 Pl

aces

+/-

.03

3 Pl

aces

+/-

.015

Frac

tions

+/-

1/32

"

Will

ough

by In

dust

ries

Inc.

Indi

anap

olis

, Ind

iana

Tole

ranc

esEx

cept

as

Title

or P

art D

escr

iptio

n:

Mat

eria

l:D

raw

n By

:D

ate:

Rev

isio

n #:

Dra

win

g #: Ap

prov

ed B

y:

VAVL

E AS

SY, W

ASH

FOU

NT

4-ST

ATIO

N (E

L)

TRB

11/7

/11

B

8031

05-4

EW

Job

Nam

e:Pa

rt N

umbe

r:N

/A

Scal

e:1:

8Q

ty:

Shee

t:1

Of 1

N/A

Not

edAn

gle

+/- 1

ITEM

#PA

RT

#D

ESC

RIP

TIO

NQ

TY.

170

0480

E P

ower

s 48

0E M

ixin

g Va

lve

12

9805

06FL

EXH

OSE

, 6"

13

8001

33#1

0-16

SEL

F TA

P TY

PE B

HEX

HEA

D S

CR

EW10

498

0183

CH

ECKS

TOP

ASSE

MBL

Y1

598

0501

4PM

1-M

A4 V

alve

Bra

cket

- Pl

astic

16

9804

08E1

L VA

LVE

ASSE

MBL

Y3

798

0197

PLAS

TIC

VAL

VE C

OU

PLIN

G3

898

0164

O-R

ING

, #01

56

998

0600

AVA

LVE

FITT

ING

ASS

EMBL

Y, 3

/8" E

LBO

W4

1098

0140

SPR

ING

CLI

P11

1198

0408

PRE1

L VA

LVE

ASSE

MBL

Y, R

IGH

T - P

LUG

GED

PO

RT

112

9805

20FL

EXH

OSE

, 20"

(NO

T SH

OW

N)

2

11

3

4

6

PAR

T #1

2 - F

LEXH

OSE

, 20"

NO

T SH

OW

NN

OTE

:1

10

7

2

5

9

8

WIL

LOU

GH

BY

DR

AWIN

G:

Elec

tron

ic V

alve

Det

ail

Replacement Part Numbers

Page 34: Installation peration Manual - Willoughby Industries

Page 34Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

TOLE

RAN

CES

FRAC

TIO

NS:

ATR

B

TRB

03/1

5/11

09/2

3/09

E1

OF

1

STAN

DAR

D

9804

08

1:2

PAR

T #:

E1L

VALV

E AS

SEM

BLY

(ALL

PO

RTS

OPE

N)

SHEE

T:R

EV�:

OR

IG.:

REV

ISIO

N:

SCAL

E:R

EF�:

MAT

'L:

Indi

anap

olis

, Ind

iana

NO

TED

EXC

EPT

AS

ANG

LE:

TITL

E / D

ESC

.:

3 PL

CS:

Will

ough

by In

dust

ries

Inc.

2 PL

CS:

0�03

0�01

51/

32"

1

SIZE

:

PAR

TS L

ISTE

D IN

TH

E PV

K R

EPAI

R

KITS

AR

E N

OT

SOLD

IND

IVID

UAL

LY

NO

TE:

REP

AIR

KIT

OR

DER

ING

#'S

AR

E LI

STED

IN T

HE

EXPL

OD

ED V

IEW

.

NO

TE:

ITEM

#PA

RT

#D

ESC

RIP

TIO

NQ

TY.

198

0420

SIN

GLE

TEM

P BA

SE w

/INSE

RTS

(ALL

PO

RTS

OPE

N)

12

9803

05W

ATER

SID

E D

IAPH

RAG

M/A

DAP

TOR

ASS

Y.1

398

0565

ARM

ATU

RE

BUM

PER

ASS

EMBL

Y, E

L VA

LVE

14

9805

33SP

RIN

G, 5

/8 2

4v V

ALVE

15

9805

30AR

MAT

UR

E C

AP, 2

4v V

ALVE

16

9801

70A

#8-3

2 x

1/2

" SC

REW

47

9805

32C

OIL

, 24V

DC

18

9805

34N

YLO

N N

UT,

5/1

6-18

1

5

6

2

PVK-

3

(2-8

) PLU

S (*

) BEL

OW

* EVK

-4 K

IT IN

CLU

DES

3808

97 V

ALVE

SEA

T W

/ 0-R

ING

(NO

T SH

OW

N)

8

1

7

33

4

EVK-

4 KI

T

2

EXPL

OD

ED V

IEW

ASSE

MBL

ED V

IEW

WIL

LOU

GH

BY

DR

AWIN

G:

Elec

tron

ic V

alve

Det

ail

Replacement Part Numbers

Page 35: Installation peration Manual - Willoughby Industries

Page 35Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

PAR

T #1

2 FL

EXH

OSE

, 20"

NO

T SH

OW

NN

OTE

:

ITEM

NO

.PA

RT#

DES

CR

IPTI

ON

QTY

.1

7004

80E

Pow

ers

480E

Mix

ing

Valv

e1

298

0506

FLEX

HO

SE, 6

"1

380

0133

#10-

16 S

ELF

TAP

TYPE

B H

EX H

EAD

SC

REW

84

9805

013

PM1-

MA3

Val

ve B

rack

et -

Plas

tic1

598

0183

CH

ECKS

TOP

ASSE

MBL

Y1

698

0406

RPN

EUM

ATIC

VAL

VE A

SSEM

BLY

27

9801

97PL

ASTI

C V

ALVE

CO

UPL

ING

28

9801

64O

-RIN

G, #

015

49

9804

06PR

PNEU

MAT

IC V

ALVE

ASS

EMBL

Y, R

IGH

T - P

LUG

GED

PO

RT

110

9801

40SP

RIN

G C

LIP

811

9806

00A

VALV

E FI

TTIN

G A

SSEM

BLY,

3/8

" ELB

OW

312

9805

20FL

EXH

OSE

, 20"

(NO

T SH

OW

N)

2

10

9

6

7

1

2

5

3

4

11

8

2 Pl

aces

+/-

.03

3 Pl

aces

+/-

.015

Frac

tions

+/-

1/32

"

Will

ough

by In

dust

ries

Inc.

Indi

anap

olis

, Ind

iana

Tole

ranc

esEx

cept

as

Title

or P

art D

escr

iptio

n:

Mat

eria

l:D

raw

n By

:D

ate:

Rev

isio

n #:

Dra

win

g #: Ap

prov

ed B

y:

VALV

E AS

SY, W

ASH

FOU

NT

3-ST

ATIO

N (P

NEU

MAT

IC)

TRB

11/7

/11

B

8031

05-3

PW

Job

Nam

e:Pa

rt N

umbe

r:N

/A

Scal

e:1:

8Q

ty:

Shee

t:1

Of 1

N/A

Not

edAn

gle

+/- 1

WIL

LOU

GH

BY

DR

AWIN

G:

Pneu

mat

ic V

alve

Det

ail

Replacement Part Numbers

Page 36: Installation peration Manual - Willoughby Industries

Page 36Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

PAR

T #1

2 - F

LEXH

OSE

, 20"

NO

T SH

OW

NN

OTE

:

ITEM

NO

.PA

RT

#D

ESC

RIP

TIO

NQ

TY.

170

0480

E P

ower

s 48

0E M

ixin

g Va

lve

12

9805

06FL

EXH

OSE

, 6"

13

8001

33#1

0-16

SEL

F TA

P TY

PE B

HEX

HEA

D S

CR

EW10

498

0501

4PM

1-M

A4 V

alve

Bra

cket

- Pl

astic

15

9801

83C

HEC

KSTO

P AS

SEM

BLY

16

9804

06R

PNEU

MAT

IC V

ALVE

ASS

EMBL

Y3

798

0164

O-R

ING

, #01

56

898

0197

PLAS

TIC

VAL

VE C

OU

PLIN

G3

998

0600

AVA

LVE

FITT

ING

ASS

EMBL

Y, 3

/8" E

LBO

W4

1098

0140

SPR

ING

CLI

P11

1198

0406

PRPN

EUM

ATIC

VAL

VE A

SSEM

BLY,

RIG

HT

- PLU

GG

ED P

OR

T1

1298

0520

FLEX

HO

SE, 2

0" (N

OT

SHO

WN

)2

6

11

1

8

10

2

3

4

59

7

2 Pl

aces

+/-

.03

3 Pl

aces

+/-

.015

Frac

tions

+/-

1/32

"

Will

ough

by In

dust

ries

Inc.

Indi

anap

olis

, Ind

iana

Tole

ranc

esEx

cept

as

Title

or P

art D

escr

iptio

n:

Mat

eria

l:D

raw

n By

:D

ate:

Rev

isio

n #:

Dra

win

g #: Ap

prov

ed B

y:

VAVL

E AS

SY, W

ASH

FOU

NT

4-ST

ATIO

N (P

NEU

MAT

IC)

TRB

11/7

/11

B

8031

05-4

PW

Job

Nam

e:Pa

rt N

umbe

r:N

/A

Scal

e:1:

8Q

ty:

Shee

t:1

Of 1

N/A

Not

edAn

gle

+/- 1

WIL

LOU

GH

BY

DR

AWIN

G:

Pneu

mat

ic V

alve

Det

ail

Replacement Part Numbers

Page 37: Installation peration Manual - Willoughby Industries

Page 37Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

NOTE

:

PAR

TS L

ISTE

D IN

TH

E PV

K R

EPAI

R

KITS

AR

E N

OT

SOLD

IND

IVID

UAL

LYNOTE

:

REP

AIR

KIT

OR

DER

ING

#'S

AR

E LI

STED

IN T

HE

EXPL

OD

ED V

IEW

.

ITEM

#PA

RT

#D

ESC

RIP

TIO

NQ

TY.

198

0420

SIN

GLE

TEM

P BA

SE w

/INSE

RTS

(ALL

PO

RTS

OPE

N)

12

9803

05W

ATER

SID

E D

IAPH

RAG

M/A

DAP

TOR

ASS

Y.1

398

0310

WAT

ER S

IDE

DIS

K AS

SEM

BLY

14

9801

36SP

RIN

G, W

ATER

SID

E D

IAPH

RAG

M1

598

0126

BAR

RIE

R C

UP

16

9801

27O

-RIN

G M

1.5x

32 B

UN

A-70

17

9804

10M

ETER

ING

VAL

VE B

OD

Y AS

SEM

BLY

18

9801

35SP

RIN

G, A

IR S

IDE

MAG

NET

19

9804

05M

ETER

ING

VAL

VE M

AGN

ET/C

UP

ASSE

MBL

Y1

1098

0130

DIA

PHR

AGM

, AIR

SID

E, P

NEU

MAT

IC M

ETER

ING

VAL

VE1

1198

0134

AIR

SID

E SP

RIN

G1

1238

0801

MAI

R S

IDE

TOP

CO

VER

113

9800

01A

#8-3

2 x

1 1/

4" S

CR

EW4

PVK-

1M, P

VK-2

, & P

VK-3

PAR

TS A

RE

AVAI

LABL

E IN

KIT

FO

RM

ON

LY.

NOTE

:

TOLE

RAN

CES

FRAC

TIO

NS:

MW

AA

9804

06R

10/1

8/12

8/31

/16

TRB

STAN

DAR

D

1 O

F 1

1:2.

5

PAR

T #:

PNEU

MAT

IC M

ETER

ING

VAL

VE A

SSEM

BLY

- (R

IGH

T)

SHEE

T:R

EV.:

OR

IG.:

REV

ISIO

N:

SCAL

E:R

EF.:

MAT

'L:

Indi

anap

olis

, Ind

iana

NO

TED

EXC

EPT

AS

ANG

LE:

TITL

E / D

ESC

.:

3 PL

CS:

Will

ough

by In

dust

ries

Inc.

2 PL

CS:

0.03

0.01

51/

32"

1

SIZE

:

22

13

12

10

11

7

8

3

7 7

3

6

5

4

99

77

1

EXPL

OD

ED V

IEW

PVK-

2(P

ART#

: 2-4

)

PVK-

3(P

ART#

: 2)

PVK-

4M(IN

CLU

DES

KIT

SPV

K-1M

& P

VK-2

)

PVK-

1M(P

ART#

: 5-1

2)

THR

U

VIEW

FR

OM

BO

TTO

M O

F VA

LVE

INLE

T /

OU

TLET

INLE

T /

THR

U

ASSE

MBL

ED V

IEW

WIL

LOU

GH

BY

DR

AWIN

G:

Pneu

mat

ic V

alve

Det

ail

Replacement Part Numbers

Page 38: Installation peration Manual - Willoughby Industries

Page 38Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

D

RAW

ING

: 9V

Bat

tery

Ope

rate

d Va

lve

Det

ail

9

8

4

1

5

3

11

2

67

10

NO

TE:

PAR

T #9

8052

0 FL

EXH

OSE

, 20"

NO

T SH

OW

N

ITEM

NO

.PA

RT

#D

ESC

RIP

TIO

NQ

TY.

198

0501

3PM

1-M

A3 V

ALVE

BR

ACKE

T1

298

0183

CH

ECKS

TOP

ASSE

MBL

Y1

398

0140

SPR

ING

CLI

P, R

OU

ND

84

8001

33#1

0-16

SEL

F TA

P TY

PE B

HEX

HEA

D S

CR

EW8

598

0600

AVA

LVE

FITT

ING

ASS

EMBL

Y, 3

/8" E

LBO

W3

698

0197

PLAS

TIC

VAL

VE C

OU

PLIN

G2

798

0164

O-R

ING

, #01

54

898

0506

6" F

LEX

HO

SE, 1

/2 F

.I.P

CO

NN

ECTI

ON

19

7004

80E

POW

ERS

LFe4

80 M

IXIN

G V

ALVE

110

9804

16VA

LVE

ASSE

MBL

Y, B

ATTE

RY

OPE

RAT

ED2

1198

0416

PRVA

LVE

ASSY

, BAT

TER

Y O

PER

ATED

, RH

PLU

GG

ED P

OR

T1

1298

0520

20" F

LEX

HO

SE, 1

/2 F

.I.P

CO

NN

ECTI

ON

2

NAL

NAL

4/16

/21

4/16

/21

A1

OF

11:

3

SEE

BOM

PAR

T #:

VALV

E AS

SY, W

ASH

FOU

NT

3-ST

ATIO

N (B

O)

SHEE

T:R

EV.:

OR

IG.:

REV

ISIO

N:

SCAL

E:R

EF.:

MAT

'L:

TITL

E / D

ESC

.:

TOLE

RAN

CES

EX

CEP

T AS

N

OTE

D

2 PL

CS:

3 PL

CS:

FRAC

TIO

NS:

ANG

LE:

0.03

0.01

51/

4"1

ASI

ZE:

Will

ough

by In

dust

ries

, Inc

.In

dian

apol

is, I

ndia

naST

AND

ARD

8031

05-3

BW

Replacement Part Numbers

Page 39: Installation peration Manual - Willoughby Industries

Page 39Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

D

RAW

ING

: 9V

Bat

tery

Ope

rate

d Va

lve

Det

ail

11

10

4

1

6

3

9

2

7

8

5

NO

TE:

PAR

T #9

8052

0 FL

EXH

OSE

, 20"

NO

T SH

OW

N

ITEM

NO

.PA

RT

#D

ESC

RIP

TIO

NQ

TY.

198

0501

4PM

1-M

A4 V

ALVE

BR

ACKE

T1

298

0183

CH

ECKS

TOP

ASSE

MBL

Y1

398

0140

SPR

ING

CLI

P, R

OU

ND

114

8001

33#1

0-16

SEL

F TA

P TY

PE B

HEX

HEA

D S

CR

EW10

598

0416

VALV

E AS

SEM

BLY,

BAT

TER

Y O

PER

ATED

36

9806

00A

VALV

E FI

TTIN

G A

SSEM

BLY,

3/8

" ELB

OW

47

9801

97PL

ASTI

C V

ALVE

CO

UPL

ING

38

9801

64O

-RIN

G, #

015

69

9804

16PR

VALV

E AS

SY, B

ATTE

RY

OPE

RAT

ED, R

H P

LUG

GED

PO

RT

110

9805

066"

FLE

X H

OSE

, 1/2

F.I.

P C

ON

NEC

TIO

N1

1170

0480

EPO

WER

S LF

e480

MIX

ING

VAL

VE1

1298

0520

20" F

LEX

HO

SE, 1

/2 F

.I.P

CO

NN

ECTI

ON

2

NAL

NAL

4/16

/21

4/16

/21

A1

OF

11:

4

PAR

T #:

VALV

E AS

SY, W

ASH

FOU

NT

4-ST

ATIO

N (B

O)

SHEE

T:R

EV.:

OR

IG.:

REV

ISIO

N:

SCAL

E:R

EF.:

MAT

'L:

TITL

E / D

ESC

.:

TOLE

RAN

CES

EX

CEP

T AS

N

OTE

D

2 PL

CS:

3 PL

CS:

FRAC

TIO

NS:

ANG

LE:

0.03

0.01

51/

4"1

ASI

ZE:

Will

ough

by In

dust

ries

, Inc

.In

dian

apol

is, I

ndia

naST

AND

ARD

8031

05-4

BW

Replacement Part Numbers

Page 40: Installation peration Manual - Willoughby Industries

Page 40Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

4

3

2

1

6

5

7

PVK-

3 KI

T (IT

EM #

: 2)

BVK-

4

ITEM

#PA

RT

#D

ESC

RIP

TIO

NQ

TY.

198

0420

RSI

NG

LE T

EMP

BASE

w/IN

SER

TS -

PLU

GG

ED P

OR

T1

298

0305

WAT

ER S

IDE

DIA

PHR

AGM

/AD

APTO

R A

SSY.

13

9801

14C

OIL

AD

APTE

R, E

1L V

ALVE

14

9801

70A

#8-3

2 x

1/2

" SC

REW

W/S

EMS

SPLI

T L/

W4

598

0164

O-R

ING

, #01

51

670

0255

CO

IL A

SSEM

BLY,

9VD

C L

ATC

HIN

G, B

ATTE

RY

OPE

RAT

ED1

798

0680

WAS

HER

, NYL

ON

, 0.7

5"ID

, 1.0

0"O

D1

EEF

MW

10/1

2/16

11/3

0/15

A1

OF

11:

2

SEE

BOM

PAR

T #:

VALV

E AS

SY, B

ATTE

RY

OPE

RAT

ED, R

H P

LUG

GED

PO

RT

SHEE

T:R

EV.:

OR

IG.:

REV

ISIO

N:

SCAL

E:R

EF.:

MAT

'L:

TITL

E / D

ESC

.:

TOLE

RAN

CES

EX

CEP

T AS

N

OTE

D

2 PL

CS:

3 PL

CS:

FRAC

TIO

NS:

ANG

LE:

0.03

0.01

51/

32"

1

ASI

ZE:

Will

ough

by In

dust

ries

, Inc

.In

dian

apol

is, I

ndia

naST

AND

ARD

9804

16PR

D

RAW

ING

: 9V

Bat

tery

Ope

rate

d Va

lve

Det

ail

Replacement Part Numbers

Page 41: Installation peration Manual - Willoughby Industries

Page 41Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

PIEZ

O H

EAD

KIT

DET

AIL

DR

AWIN

G:

Push

butto

n D

etai

lReplacement Part Numbers

Page 42: Installation peration Manual - Willoughby Industries

Page 42Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

6

2

3

4

5

7

1

ITEM

#PA

RT

#D

ESC

RIP

TIO

NQ

TY.

160

0307

RK

REP

AIR

KIT

FO

R D

IAPH

RAG

M P

USH

BUTT

ON

PU

MP

12

380

840

FITT

ING

, HO

SE B

ARB,

PU

SH-IN

, 1/1

6" (B

RAS

S)1

3 3

8050

6MA

BOD

Y, P

USH

BU

TTO

N D

IAPH

RAG

M P

UM

P,M

OLD

ED1

4 6

0020

1D

IAPH

RAG

M, P

NEU

MAT

IC P

UM

P1

5 3

8050

4MA

CAP

, DIA

PHR

AGM

PU

MP,

MO

LDED

16

6000

57PU

SHBU

TTO

N, D

IAPH

RAG

M P

UM

P1

738

0124

SLEE

VE, D

IAPH

RAG

M P

UM

P PU

SHBU

TTO

N1

NO

TE: P

ARTS

2 A

ND

3 M

UST

BE

PUR

CH

ASED

TO

GET

HER

TOLE

RAN

CES

FRAC

TIO

NS:

AJB

U

MW

10/2

6/16

3/14

/00

A1

OF

1

STAN

DAR

D

6003

07

1:1

AS N

OTE

D, S

EE B

OM

PAR

T #:

(PPB

) PN

EUM

ATIC

PU

SHBU

TTO

N

SHEE

T:R

EV�:

OR

IG.:

REV

ISIO

N:

SCAL

E:R

EF�:

MAT

'L:

Indi

anap

olis

, Ind

iana

NO

TED

EXC

EPT

AS

ANG

LE:

TITL

E / D

ESC

.:

3 PL

CS:

Will

ough

by In

dust

ries

Inc.

2 PL

CS:

0�03

0�01

51/

32"

1

SIZE

:

WIL

LOU

GH

BY

DR

AWIN

G:

Push

But

ton

Det

ail

Replacement Part Numbers

Page 43: Installation peration Manual - Willoughby Industries

Page 43Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

DR

AWIN

G:

Spra

y H

ead

Det

ail

ITEM

#PA

RT

#D

ESC

RIP

TIO

NQ

TY.

180

0001

WAS

HFO

UN

TAIN

SPR

AYH

EAD

BAS

E, 4

5, S

.S.

12

3201

57A

SPR

AY H

EAD

, 0.5

GPM

, 13/

16"-

27 T

HR

EAD

1

ABE

H

BEH

08/0

5/14

08/0

5/14

A1

OF

1

STAN

DAR

D

3201

57A-

ASM

B

3:2

PAR

T #:

SPR

AY H

EAD

ASS

Y�, 0

�5 G

PM

SHEE

T:R

EV�:

OR

IG.:

REV

ISIO

N:

SCAL

E:R

EF�:

MAT

'L:

TITL

E / D

ESC

.:W

illou

ghby

Indu

stri

es In

c.In

dian

apol

is, I

ndia

na3

PLC

S:

NO

TED

EXC

EPT

AS

TOLE

RAN

CES

2 PL

CS:

FRAC

TIO

NS:

ANG

LE:

0�03

0�01

51/

32"

1

SIZE

:

1

2

WIL

LOU

GH

BY

Replacement Part Numbers

Page 44: Installation peration Manual - Willoughby Industries

Page 44Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

DR

AWIN

G:

Liqu

id S

oap

Dis

pens

er D

etai

lReplacement Part Numbers

Page 45: Installation peration Manual - Willoughby Industries

Page 45Rev. 9/2021 www.willoughby-ind.com

Installation & Operation ManualAquafount® 180° WashfountainWAF-5403 Series / WAF-5404 Series

Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837

WarrantyAquasurf® Solid Surface Products are a homogeneous blend of resins, mineral filler and colorant manufactured for panels, molded and/or shaped products and components. Aquasurf® Solid Surface products provide a luxurious appearance with the durability of stain proof, impact resistant, burn resistant material with ease of maintenance and cleaning.

Willoughby Industries, Inc. warrants to commercial and institutional purchasers only that each unit will be free from defects in workmanship and materials under normal use and service upon the following terms and conditions. The period during which Aquasurf® components are warranted as follows:

1. Aquasurf® solid surface components are warranted for 2 years from date of shipment.

2. All other components warranted for 1 year from date of shipment.

This warranty does not cover installation or any other labor charges and does not apply to any components damaged by accident, abuse, improper installation or improper maintenance. This warranty does not cover any installation that did not comply with national, state and local building, plumbing or electrical codes. The warranty is limited to replacing or repairing at Willoughbys option, transportation charges prepaid by the purchaser, any Aquasurf® component or part which upon our inspection shall be deemed as defective within the limitations of this warranty. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of the purchaser and the sole liability of Willoughby Industries, Inc. Willoughby Industries, Inc. shall not otherwise be liable under any indirect damages caused by defects in the repair or replacement thereof.

This warranty only extends to commercial and institutional purchasers and does not extend to any others, including consumer customers of commercial institutional purchasers. This warranty is in lieu of all other warranties, expressed or implied, including implied warranty of merchantability or fitness or a particular purpose or otherwise.

Warranty