installation & operating manual trident boilers: sf160, sf260,...
TRANSCRIPT
-
Installation & Operating Manual
Trident Boilers: SF160, SF260, SF360
SAFETY NOTICEPLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND/OR USE YOUR NEW BOIL-ER. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
IF THIS HARMAN BOILER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PER-MIT. Cette guide d’utilisation est disponible en francais. Chez votre concessionnaire de Harman Stove Company.
SAVE THESE INSTRUCTIONS
R3
-
�
-
�
Congratulations, Youhavejustpurchasedthefinestwood/coalboileravailable.HarmanTridentboilersareconstructedofhighqualitymaterialsandaremanufacturedbyahighlyskilledteamofassemblymen.Eachboilerisinspectedandpressuretestedforqualityassurance.
Thismanualisdesignedtoprovideallofthebasicinformationneededforasafeandproperinstallation.However,therearemanyskillsneededthatcannotbelearnedbyreadingthismanual.HarmanStoveCompanyrecommendsthattheinstallationbeperformedbyaplumbingandheatingexpert.
TheHarmanTridentBoilersaredesignedtooperatesafe,easyandautomatically.Youmayhowever,needtolearnafewbasicskillstomaintainafire.Especiallyifthisisyourfirstventureintosolidfuelburning.Ifyouhaveanyproblems,re-readtheseinstructions.Ifyoucannotresolvetheissue(s),ContactyourHarmanStovedealer.
TABLE OF CONTENTS
PackingList
Installation Aquastat Wiring Venting Plumbing
Operating Instructions Starting a Wood Fire Starting a Coal Fire Loading Fuel ShakingAshes
Safety Tips
Maintenance
Specifications
Warranty
4
56778
1010111111
12
13
13
14
-
�
PackingList
TheFollowingitemsaresuppliedwithyourHarmanTridentBoiler:
PleasenotifyyourHarmanDealerifyouaremissinganyitems.
--ShakerHandle--JohnsonControlsAquastat-(3)pieces;A350Controllerw/Sensorwire S350 Stage Module Y350PowerSupply--ImmersionWell--DinRailand(2)EndClamps--TerminalBox--TerminalBlockand(2)#8-32nuts--Pressure Relief Valve (30 psi.)--Temperature/PressureGauge--AutomaticDraftControlAssembly--(1pc.)FlexConduitw/(2)90°Fittingsw/nuts,and(3)ChaseNipplesw/nuts--(2)ManualDraftControlKnobAssembly--(3) Brass Coil Spring Handle--Ash Pan--WarrantyRegistrationForm
Notice:The Aquastat controls supplied with the Trident Boiler are designed only to maintain water temperature within
the boiler. The actual heating sys-tem is controlled separately by your
thermostat(s) opening zone valves or energizing circulation pump(s).
Do not attach a thermostat to the sup-plied controls.
-
�
InstallationGetting Started Thesheetmetalsidesandtopareeasilyremovedtoreducethechanceofdentsand/orscratchesinthefinish.Simplyliftthetopoff,andthatwillallowthesidestobepulledawayandup,forremoval.Tore-install,slidethechannel,atthebottomofeachsidepiece,overthelipatthebot-tomoftheboiler,andholddownwardwhilemov-ing the side panel into place. Then slide the top downoverthesides.
NOTE:Thesheetmetaltopholdsthesidesinplace,thus,noboltsorscrewsareneeded.
Caution: Boiler should not Be installed Closer than 36 inChes (915 mm) to any ComBustiBle ma-terial
Locating Boiler Placetheboilerasclosetothechimneyaspossible,whilestillmaintainingtheabovemen-tionedclearances.Bolttheshakerhandleontotheblockonthesideoftheboiler,usingthe(2)5/16X3/4in.boltsandlock-washers.Assembly InstalltheTemperature/PressureGaugeintothepipestubinthecenteroftheroundplateonthefrontoftheboiler(FIG.1) InstalltheA350sensorwireallthewayintotheimmersionwellandscrewthewellintooneofthetopholesonthefaceoftheboiler. Turnthepressurereliefvalveintothestubontopoftheboiler,nexttothesupplyoutletfit-ting.NOTE: Use teflon tape to seal the threads on all fittings. Any unused fittings must be plugged. Boltthetwomanualdraftcontrolsthrough the holes in the top load door. (FIG.2) Thedraftcontrolknobshouldspinfreelyandopentoadistanceofapproximately3/8in.fromthedoorsurface,whilebeingabletocloseagainstthe door surface.
FIG.�
�/8to1/�in.
ImmersionWell
Temp/PressureGauge
OptionalElectricBack-upElements
AutomaticDraftControl
PressureReliefValve
FIG.1
JohnsonControlsAquastatand
TerminalBlock
ShakerHandle
DomesticHotWaterCoilOption
-
�
BolttheAutomaticDraftControlthroughthe1/2in.holeinthecenterofthebottomdoor.BesuretoholdtheDraftControlstraightwhiletightening.Feedthetwowiresfromthedraftmo-torthroughtheflexibleconduitanda90˚fitting.Securethefittingtothedraftmotorandthatendoftheconduitatthistime.ChecktheflapperdoorontheAutomaticDraftControlassuringthatitmovesfreely. Installthe(3)brasscoilspringhandlesontothedoorlatchesandtheshakerhandle.Startthespringhandleontotheshaftandtwistitcoun-ter-clockwisewhilepushing.
Aquastat Installation (See optional items, page 7) Lay the din rail onaflatsurface,withtheflatsidedown.Secureoneendclamp,ontheleftside.SlidetheA350controllerontotherailfromrighttoleftuntilitisagainsttheendclamp.SlidetheY350ontotherail and guide the plug-in connector, joining it to the A350. Next, install the S350, again, guiding the plug-in connector carefully. Install the other endclamptotherightsideofthedinrail.Removethecoversfromallthreecontrolsbylooseningfourscrewseach.Installtheterminalboxtothecontrolsusing(3)chasenipplesandlocknuts,suppliedwiththekit.Usingthefourholesintheterminalbox,mounttheterminalboxandcontrolstotheboilersheetmetalsideasshowninFig.1.Using(2)#8-32nuts,installtheterminalblockontothestudslocatedinsidetheterminalbox.
Wiring Diagram
Installation
FIG.�
-
�
Wiring and Electrical Followingthewiringdiagram,runallwirestotheirdesignatedconnections.Savethemainpowerforthelasthook-up,andleavethebreakerintheoffposition.ThesensorwiresattachtotheA350Controllerontheterminalsmarked“sen”and“com”.Makesurethesensorissubmergedfullyintothewellandsecuredwiththeset-screws.Setting The Aquastat InsidetheA350control,youwillseeasquarejumper,andadifferentialdial.Besurethejumperisinthe“Heating”position.Thedifferen-tialdialissettodeterminehowlow,belowthetemperaturesetpoint,youwantthewatertem-peraturetogobeforetheAutomaticDraftControlopens.Agoodinitialsettingforthisdialis5°.Besurethe120Vwiresareattachedtothecommonandthenormallyopenterminals,andreplacethecover.Theexternaldialissetforthewatertem-peratureyouwishtomaintain,agoodsettingis180°. Inside the Y350 control, ensure that your wiresareconnectedtothe120VACterminals,and replace the cover. InsidetheS350control,whichisusedasoverheatprotection,you’llseetwodials;offset,anddifferential.Thereisalsoajumperwhich,inthiscase,getsplacedinthe“cooling”position.TheoffsetdialsetsthenumberofdegreesabovetheA350setpointthatyouwanttheoverheatdumptoactivate.Agoodsetpointwouldbe20°.Thatwouldmeanthatifthewaterreaches200°,usingtheA350setpointof180°,theS350wouldclose it’s contacts and energize the overheat dumpzone.Thedifferentialdialsetsthepointthattheoverheatdumpwouldstop.Withthedifferen-tialsetat15°,usingthetemperaturesabove,thecircuitwouldre-open,stoppingtheoverheatdumpatawatertemperatureof185°.The120Vwiringisattachedonthenormallyopenandthecommonposition.Thenormallyclosedpositionisnotused. Re-install the covers onto the three Con-trols.
Optional Items Thereisadomestichotwatercoilavailablefor your Trident Boiler. The coil installs in the front oftheboiler,andallowsyourdomesticwatertobeheatedbytheheatingsystemwater.Installthecoilnow,byremovingtheroundplateandreplac-ingitwiththecoilandit’sroundplate.Besuretotightentheboltsevenly,toensureagoodseal. Ifelectricback-upisdesired,installnow.Therewillbetwoadditionalcontrolboxestoaddtoyouraquastat,whichwillrequiretheuseofalongerdinrail.ThetwoheatingelementswillinstallintothefrontoftheboilerasshowninFig.1
FIG.�
Venting TheHarmanTridentBoilermustbein-stalledintoachimneyapprovedforsolidfuelburningappliances.IntheU.S.,theboilermustbeconnectedto;(1)aprefabricatedchimneycomply-ingwiththerequirementsforTypeHTchimneysintheStandardforChimneys,FactoryBuilt,Resi-dential Type and Building Heating Appliances, UL 103.Or;(2)acodeapprovedmasonrychimneywithaflueliner.InCanada,withprefabricatedchimneysystemstestedandlistedtotheHighTemperatureChimneyStandardULCS-629,orwithacodeapprovedmasonrychimney.Theminimumrecommendedheightforanychimneyis16ft.(4.8m)abovethefluecollar.Donotre-ducefluediameter.Nominalsizeflueis8X8in.or equivalent, up to 8 X 12 in. Codes also require thatthechimneymustextendaminimumof
Installation
-
8
3feet(0.9m)abovethepointatwhichtheyexitfromtheroof,itmustalsoextend2feet(0.6m)abovethehighestpointwithina10ft.(3m)radius.
DO NOT CONNECT THIS uNIT TO A CHImNEy fLuE THAT IS SErVING ANOTHEr AppLIANCE.
Limitconnectorpipeto8ft.orless,withnomorethantwoelbows.Allhorizontalsectionsshouldhave1/4in.riseperfoot.Thechimneymustbecapableofprovidingadraftreadingofatleast.06in.ofwatercolumn.Abarometricdampercanbeinstalledtopreventexcessiveanderraticdraft.Allconnectorpipeshouldbesecuredwithsheetmetalscrewsateachjoint.
Installationplumbing TheHarmanTridentBoilercanbeusedasa“StandAlone”boilerorasanadd-ontoanexist-inghotwaterheatingsystem. Thediagramsinthismanualaremeanttoshowthenecessaryequipmentandpiping.Yoursystemmaylookverydifferent.However,ifconfig-uredproperly,thesameresultswillbeachieved. Fig.6showsatypicalplumbingdiagramfortyingintoanexistingsystem.Thismethodprovideswatercirculationbetweenthetwoboilerswithacirculatingpump.Inthissetup,thedomes-ticwatercoilintheexistingboilerwillbeheated,makingitunnecessarytoinstallawatercoilintheTrident Boiler. Tying-intoanexistingboilermustbedoneinthereturnlinebetweenthecirculatorandtheexistingboiler.Runapipefromtheretoasmallcirculator,andthenintothe1-1/4in.fittingontherearoftheTridentBoiler.Nextrunapipefromthe1-1/4in.fittingonthetopoftheTridentBoilertoaTeefittinginthesupplylineoftheexistingboiler.ThisTeefittingmustbeinstalledbetweentheex-istingboilerandtheFlowControlValve,asshowninFig.6.Anairvalveshouldbeinstalledonthisline also.
FIG.�
FIG.�
AirValve
Notice:The Aquastat controls supplied with the Trident Boiler are designed only to maintain water temperature within
the boiler. The actual heating sys-tem is controlled separately by your
thermostat(s) opening zone valves or energizing circulation pump(s).
Do not attach a thermostat to the sup-plied controls.
-
�
Thecirculatorinstalledbetweenthetwoboilersmaybehookeduptoruncontinuouslyduringtheheatingseasonor,anadditionalS350control(notsupplied)couldbeinstalledtoturnitonandoffautomatically.Thiscontrolmustbeusedasa“closeonriseoftemperature”(jumperincoolingposi-tion). HarmanStoveCompanyrecommendsthat1-1/4in.pipebeusedbetweenthetwoboilers.AlsorecommendedisthatthefirstsectionofpipeoffofthetopoftheTridentBoilerbethreadedgalvanizedorthreadedblack-steelpipe. TheHarmanTridentBoilerissuppliedwithadualfunctionaquastat.TheA350isusedtocontroltheautomaticdraftcontrolwhetheropen,toincreaseheat,orclosed,todecreaseheat.TheS350isusedasoverheatprotection.Sinceawoodorcoalfireisstillproducingheatwhenthedraftisclosed,thisoverheatprotectionisrequired.YoucouldhavetheS350energizeacirculatingpumporazonevalveseparatefromtheheatingsystem,oritcouldbehookedupsothatitflowstheheatedwaterthroughoutthesystem.Eitherway,itmustbeabletoflowawayfromtheboiler. Figure7showsatypicalschematicoftheTridentboilerasa“standalone”system.Note;thecrossoverpipe(#12)isnottotallynecessarybutisrecommendedtoprovidecirculationwithintheboilerwhiletheheatingsystemissatisfied.Thiswillensureaneventemperaturewithintheboiler.Thetemperingvalveshown(#10)istopreventexcessivetemperatureofthedomesticwater.
FIG.�
Installation
-
10
OperationAutomatic Draft Control Theheatoutputisregulatedbytheauto-maticdraftcontrolonthebottomdoor.Theelectricmotor(A)opensandclosestheflapperdoor(B).Openingandclosingtheflapperdoorregulatestheairflowintothefirebox. Themaximumairflowcanbeadjustedbyturningtheadjustingbolt(C).Turncounter-clockwiseformoreair,andclockwiseforlessair.Adjustthisboltonlywhiletheflapperdoorisintheclosedposition.Otherwise,motordamagecouldoccur. Theidleairadjuster(D)controlsthemini-mumamountofairthatentersthefirebox.Adjust-mentismadebyturningtheadjusterverticalforzeroidleair,orhorizontalformaximumidleair.ItisbesttostartoutwithamediumsettingasshowninFigure9.
FIG.8
FIG.�
Starting a Wood fire Makesuretheboilerandallpipingisfullofwaterandthatallairhasbeenpurgedfromthesystem.Never start a fire without water in the system. An explosion will occur. Turnonelectricalpowertotheboiler.Thisshouldcausetheautomaticdraftcontroltoopen.Opentheashpandoortoallowfreeairmove-ment.Withthefireboxdooropen,crumbleap-proximately8sheetsofnewspaperandplaceonthegrates.Laysomesmallkindlingontopofthenewspaper.Besurethiskindlingisdryandnomorethan3/4in.indiameter.Layerthekindlinginacriss-crosstypepattern,toallowmaximumairflow.Nextlaysomelargerpiecesofwoodontopofthekindling(approximately2in.diameter).Usingamatchorlighter,lightthepaperjustinsidethedoor.Closeandlatchthefireboxdoorandal-lowthefiretoburnafewminutes.Afteraboutfiveminutes,closetheashpandoorandre-openthefireboxdooraninchortwo,toallowthesmoketoclear.Add4or5largerlogs(about4in.diameter)tothewellestablishedfireandclosethefireboxdoor.Leavetheashpandooropenforaboutfiveminutesonly.Nowopenthefireboxdoorusingthesamemethodasbefore,alwaysclosingtheashpandoorbeforeopeningthefireboxdoor.Nowyoucanloadthefireboxtothedesiredlevel.Youmayloadwoodtothetopofthefirebox.Closeandlatchthedoor.Theashpandoormayagainbeopenedtospeedtheignitionprocess.Do not leave the boiler unattended with any door open. Afterthewoodisburningwell,closetheashpandoor.Theautomaticdraftcontrolwillnowregulatethefire,basedontemperaturedemand. Theidleairadjustermustbetunedtowherethefiredoesn’tgooutduringlongperiodswithnodemand.Experiencewilldictatethebestsettingforyourinstallation.Normally,thetwomanualdraftcontrolsonthefireboxdoorarekeptclosedwhileburningwood.
-
11
OperationStarting a Coal fire Makesuretheboilerandallpipingisfullofwaterandthatallairhasbeenpurgedfromthesystem.Never start a fire without water in the system. An explosion will occur. Turnonelectricalpowertotheboiler.Thisshouldcausetheautomaticdraftcontroltoopen.Opentheashpandoortoallowfreeairmove-ment.Usethesameprocedureasstartingawoodfireexcept,donotloadthelargerdiameterwoodUsewoodabout2in.diametermaximum.Thissizewillformaveryhotcharcoalbedinlesstime.Again,theashpandoormaybeopenedperiodi-cally to speed the ignition process. DO NOT LEAVE THE BOILEr uNATTENDED WITH ANy DOOr OpEN. Whenyouhaveaccumulatedasubstantialcharcoalbed,startaddingathinlayerofcoal.PeaorNutsizedcoalisbetterforstartingthanStovecoal. Whenthefirstlayerisburningwithsomeblueflame,continuetoaddthinlayersofcoaluntilthereisasolidbedofburningcoal.Leteachlayerburnablueflamebeforeaddinganotherlayer.Ad-ditionalcoalcanbelayeredinuntilthebedisap-proximately10inchesdeep.Bynow,youshouldhavetheashpandoorclosed,andtheautomaticdraftcontrolwillcontinuetoregulatethefire. Theidleairadjustermayneedtobesetforslightlylessairforcoalthanwood.Hereagain,experiencewilldictatethebestsetting.Themaxi-mumairboltcanbeturnedalltheway“counter-clockwise”toallowforaquickerrecovery.Neveradjustthisboltwiththeflapperopen. Thetwomanualdraftcontrols,onthefireboxdoor,areusedtoallowsecondaryairtopassoverthefirewhenburningcoal.Thishelpstoburnthegassesthatareemittedfromthecoalas it is heated. Your setting for these draft controls shouldbebetween1/2and1completeturnfromclosed.Adjustbothcontrolsequally.
Loading Coalshouldneverbeaddedunlessthereisareasonablyhotfire.Thecoalbedshouldbebrightandvigorous.Ifyouhaveanactivecoalbed,fullloadscanbeaddedatanytime.Ifnot,addnewcoalinlayers,asdescribedinstartingacoalfire.Shaking the Grates Shakingshouldbedoneonlywhenthereisawell-establishedfire.Thefrequencyofshak-ingwilldependonthedegreeofburning.Twiceadayshakingisrecommended.Thebestresultsareachievedwithshort,choppystrokesasop-posedtolong,evenstrokes.Fullrockingofthegratesmayallowburningcoaltofallintotheashpan.Theamountofshakingiscritical,toomuchcandisruptthefirebed,andtoolittlewillrestrictair-flow.Theproperamountofshakingisnormallyachievedwhenhotredcoalsfirststarttodropthrough the grates into the ash pan. Everyeffortshouldbemadetonotletacoalfireburndowntoolow.Thiswillcausethereloadingprocesstobemuchlonger,witharealgoodchanceoflosingthefirealtogether. Donotshakeorstirwithalowfire.Opentheashpandoortogetmaximumairflowingintothefirebox.Onceburningisrestored,closetheashpandoorandaddalayerofcoaltothefirebed.FollowtheinstructionsunderStartingaCoalFire.Whenthenewcoalisthoroughlyignited,andthereisasubstantialbedofhotcoals,thegratesmaythenbeshaken.Ashes and Ash removal Ashesshouldneverbeallowedtoaccu-mulateabovethetopoftheashpan.Ashesincontactwiththebottomofthegratesactasinsu-lation,whichintensifiestheheatonthegratesandcausesthemtosagorwarp.Also,toomuchashaccumulationwillrestrictair-flowwhichwillmakefiremaintenancemoredifficult.Placeashesinasealedmetalcontainer,outside,untiltheyarecooledenoughforfinaldisposal.Coalproducesconsiderablymoreashthanwood,sotheintervalsbetweenemptyingaremuchshorter.
-
1�
Safety Tips Whenopeningthefireboxdoor,itshouldbecracked,slightlyopen,forafewsecondstoallowairintoburnanygaseswhichmaybepresent.Thiswillalsoallowsmoketobedrawnawayfromthedoor.Whenevertheashpandoorisopen,itshouldbeclosedbeforeopeningthefireboxdoor.
Thefireboxshouldneverbefilledwithexcessivecoaltowheretheflueexitisblockedorimpededinanyway.
Burning coal produces Carbon monoxide. If the flue exit is blocked, the Carbon Monoxide can be forced out of the boiler, into the room, with possible fATAL consequences. With the exception of start-up or freshening ofthefire,orperformingashremoval,theashpandoorshouldbekeptclosed.
NeverinstallaHarmanTridentBoilerintoachimneywithahistoryofdown-drafts.
Keep Children Away-- may Cause Seri-ous Burns.
CAuTION: All surfaces of the boiler are hot. Do not touch. Keep children away. Serious burns will result if touched. This is a heat producing appliance.
DANGEr: fire Hazard, Do not use chemicals or flammable liquids to start or “freshen-up” a fire. Severe burns or a house fire may result. Do not burn Garbage, Gasoline, Thinners, Oil, Kero-sene Etc. An explosion, a house fire or serious personal injury could result. Keep all such liquids well away from this boiler.
Duringthefirstfewhoursofburning,abluesmokemaybeobservedrisingfromtheboiler.This is the paint going through the curing process. Itisadvisabletoincreasetheamountoffreshairintheroomduringthisbreakinperiod.Thiscanbeachievedbyopeningdoorsandwindows.Don’tbealarmed,thisisnormalandwillonlylastashortwhile.Chimney problems Not Enough Draft-Chimneyistoolow.Thegeneralruleforchimneysis16feettall,andtwofeethigherthananythingtenfeetaroundit.
Airmaybeleakinginaroundaloosefittingclean-out door.
Toomanyelbowsinconnectorpipe,orseamsandjoints of connector pipe are not secured properly.
Improperlysizedchimneyorstovepipe.
Chimneymaybeblockedwithcreosoteorbirdnestsorsimilarobstructions.
Crackedordefectivechimneyflueorliner.
Down Drafts- Trees or other topographi-calbarriersmayimpedeonchimneyperformancecausingaircurrentstobepusheddownwardintotheflue.Thiscanalsobecausedbyneighboringbuildingsorotherchimneys.
Creosote and condensation- If creo-soteorcondensationrunsoutofthechimneyorstovepipe,checkthefollowing;Chimneycaporlinermaybedefective,Boilermaybepositionedtoofarawayfromthechimneywhichwouldnotallowthechimneytowarm,Woodbeingburnedmaybegreenorwet,Boilermaybeover-sizedfortheresidencecausingittobeburnedonlowtoooften.
Excessive Draft-Thiscanbecontrolledwithabarometricdamperinthestovepipe.
Operation
-
1�
Maintenancemaintenance Thespiralchamberisbasicallyself-cleaning.However,ifthereisadraftproblemandyouhavebeenburningwoodforalongtimewithlittledemand,thespiralchamberwillneedtobecleaned.Tocleanthespiralchamber,removethestovepipeandscrapeanycreosoteordebrisfromthetopandfrontofthechamber.Therearofthechambershouldnothavemuchaccumulation.Ifitdoes,cleanitout.
NOTE:1/4”to1/2”ofcreosoteinthespiralchamberisnormal.
Thepipesinsidethefireboxwillaccumulatecreosoteifthedemandforheatistoolow,whenburningwood.1/8”to1/4”ofcreosoteisnormalonthepipesandfireboxwalls.Ifmorecreosotehasaccumulated,itshouldbescrapedoffofthesesurfaces.
NOTE:Creosoteinthefireboxcanbeburnedoffbyburningcoalforafewdays.
Thefirebricksmaybecomecrackedduringthecourseofnormaloperation.Acrackedbrickthatisstillinplace,isstilldoingitsjob,andneednotbereplacedimmediately.Ifabrickisbroken,andhasfallenoutofplace,itshouldbereplacedbeforeanyfurtherburningoccurs.ThefirebricksusedintheTridentBoilerareavailableforreplacementfromyourHarmandealer. Gasketsonthedoorsaretheretoregulateairtothefirebox.Ifagasketisfailing,you’llnoticedifficultyincontrollingthefire.Inspectthegasketsregularly,andreplacewithHarmansuppliedmate-rial only.
Specifications Sf-160 Sf-260 Sf-360Heating Capacity (Square Feet) 2200 Max. 3200 Max. 4500 Max.
ApproximateBTUperhour(woodorcoal) 90,000 130,000 180,000
AMP Rating 40 40 40
Water Capacity (US Gallon) 25 32 42
Weight 640Lbs 780Lbs 925Lbs
Hydro-Pressure Tested Yes Yes Yes
FireboxDimensions(inches) 16Wx22Lx19H 18W x 26L x 20H 18W x 30L x 25H
RecommendedLogLength(inches) 19 23 27
Door Opening Size (inches) 11 x 13 13 x 13 13 x 13
OverallDimensions(inches) 23W x 23.5L x 45H 26W x 27.5L x 45.5H 26W x 31.5L x 51.5H
FlueSize(diameter) 6 inch 7 inch 7 inch
FlueHeight(topofflue) 37.5 inches 38.75 inches 44 inches
NumberOfGrates(10Lbs.Each) 4 5 6
Type Of Fuel Coal / Wood Coal / Wood Coal / Wood
Water Inlet and Outlet Size 1.25 NPT 1.25 NPT 1.25 NPT
AutomaticDraftControl Yes Yes Yes
Aquastat Yes Yes Yes
Temperature/PressureGauge Yes Yes Yes
ASME Pressure Relief Valve Yes Yes Yes
Ash Pan With Handle Yes Yes Yes
DomesticHotWaterCoil(optional) 4 GPM 4 GPM 4 GPM
ApproximateBTUperhour(electricoption) 30,000 30,000 30,000
KilowattRating(electricoption) 9 9 9
-
1�
Warranty
1 year Limited Warranty (commercial)5 year Limited Warranty (residential)
Warrantyisnottransferable.HarmanStoveCompanywarrantsitsproductstobefreefromdefectsinmaterialandworkmanship,innormaluseandservice,forfive(5)yearsfromthedateofpurchase. Ifdefectiveinmaterialorworkmanship,andifremovedbytheownerwithin60monthsofthedateofinstallation,HarmanStoveCompanywill,atitsoption,repairorreplacetheproductasdescribedbelow. ThewarrantyaboveconstitutestheentirewarrantywithrespecttoHarmanStoveCompanyproduct.HARMAN STOVE COMPANY MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY, OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. No employee,agent,dealer,orotherpersonisauthorizedtogiveanywarrantyonbehalfofHarmanStoveCom-pany.Thiswarrantydoesnotapplyiftheproducthasbeenalteredinanywayafterleavingthefactory.HarmanStoveCompanyassumesnoliabilityfor“resultantdamagesofanykind”arisingfromtheuseofitsproducts.Inaddition,themanufacturershallbeheldfreeandharmlessfromliabilityfordamagetopropertyrelatedtotheoperation,properorimproper,oftheproduct.THEREARENOOTHERWARRANTIESWHICHEXTENDBE-YOND THE DESCRIPTION ON THE FACE HEREOF. THESEWARRANTIESAPPLYonlyifthedeviceisinstalledandoperatedasrecommendedinthemanu-al. THESEWARRANTIESWILLNOTAPPLYifdamageiscausedbyabuse,accident,improperinstallation,negligence,orusebeyondtheratedcapacity. LABORRESPONSIBILITY-Infurnishingreplacementparts,HarmanStoveCompanyassumesnore-sponsibilityforlaborexpensesforservice,removal,orre-installation. MAKINGACLAIM-Anyclaimunderthiswarrantyshallbemadetothedealerfromwhomthisappliancewaspurchased.Then,contactismadewiththemanufacturer,givingthemodel,serialnumber,dateofpur-chase,dealer’snameandaddress,plusasimpleexplanationofthenatureofthedefect. SHIPPINGCOSTS-Thetransportationchargesareasfollows: (1)CustomerPre-paysfreighttoHarmanStoveCompany (2)HarmanStoveCompanyPre-payschargesfortherepairedorreplacementunit.NOTE:Priorapproval,byphoneorinwriting,shallbemadebeforeshippingtheappliancetomanufacturer. THIS WARRANTY IS LIMITED TO DEFECTIVE PARTS-REPAIR AND/OR REPLACEMENT AT HARMAN OPTION AND EXCLUDES ANY INCIDENTAL AND CONSEQUENTIAL DAMAGES CONNECTED THERE-WITH. WARRANTYEXCLUSIONS:(1)Labor(2)Firebricks(3)DoorPacking(4)Paint(5)ActsofGod PLEASE READ THE LITTERATURE BY THE MANUFACTURER FOR THE VARIOUS ACCESSORY DEVICES.THESEDEVICESARE“WARRANTEDBYTHEMANUFACTURER”NOTBYHARMANSTOVECOMPANY. FURTHERMORE, THEESE ACCESSORY DEVICES MUST BE INSTALLED AND USED ACCORD-ING TO THE RECOMMENDATIONS OF THE MANUFACTURER. Somestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,sotheabovelimitationorexclusionmaynotapplyinyourstate. Thiswarrantygivesyouspecificlegalrights.Youmayalsohaveotherrights,whichvaryfromstatetostate,whichmaybeenforceableinacourtoflaw. REMEDIES-Theremediessetforthhereinareexclusive,andtheliabilityofsellerwithrespecttoanycontractofsaleorthingsdoneinconnectiontherewith,whetherincontract,intort,underanywarranty,oroth-erwise,shallnot,exceptashereinexpresslyprovided,exceedthepriceoftheequipmentorpartofwhichsuchliabilityisbased. CLARIFY-TheaboverepresentsthecompletewarantygiveninconnectionwithboilersmanufacturedbyHarmanStoveCompany.Noothercommitments,verbalorotherwise,shallapply,exceptbyawrittenadden-dumtothiswarranty.