Page 1: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

INSTALLATION / OPERATING MANUAL

26X / 36X ZOOM DAY & NIGHTRUGGED IR PTZ CAMERA

Distributed by

Before attempting to connect or operate this product,please read these instructions carefully and save this manual for future use.

P/N : 388062420 PRINTED IN KOREA

Page 2: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

02

RUGG

ED IR

PTZ

CAM

ERA

03

RUGG

ED IR

PTZ

CAM

ERA

TABLE OF CONTENTS 1. INFORMATION FOR USER

The lightning flash with an arrowhead symbol, within an equilateral triangle isintended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitutea risk of electric shock to persons.

TO REDUCE THE RISK OF ELECTRIC SHOCK,DO NOT REMOVE COVER (OR BACK).NO USER SERVICEABLE PARTS INSIDE.REFER SERVICING TO QUALIFIEDSERVICE PERSONNEL.

The exclamation point within an equilateral triangle is intended to alert the user tothe presence of important operating and maintenance (servicing) instructions in theliterature accompanying the appliance.

1. 3 FCC COMPLIANCE STATEMENT

1. 2 EXPLANATION OF GRAPHICAL SYMBOLS

CAUTION - Changes or modifications not expressly approved by the manufacturer could void the user'sauthority to operate the equipment.

**This installation should be made by a qualified service person and should conform to all local codes.

1. 1 WARNINGTO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT.

CAUTIONRISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION :

FCC INFORMATION - This equipment has been tested and found to comply with limits for a Class Adigital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonableprotection against harmful interference when the equipment is operated in a commercial environment.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and usedin accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which casethe user will be required to correct the interference a this own expense.

1. 4 CE COMPLIANCE STATEMENTWARNING - This is a CLASS A product. In a domestic environment this product may cause radiointerference in which case the user may be required to take adequate measures.

3p.3p.3p.3p.3p.

4p.

5p.

6p.6p.7p.9p.10p.13p.

14p.14p.14p.15p.32p.36p.46p.48p.48p.49p.49p.49p.

50p.

53p.53p.54p.

55p.

1. INFOMATION FOR USER ................................................. 1. 1 WARNING ..................................................................... 1. 2 EXPLANATION OF GRAPHICAL SYMBOLS ..................................... 1. 3 FCC COMPLIANCE STATEMENT ............................................... 1. 4 CE COMPLIANCE STATEMENT ................................................

2. PRECAUTIONS ...............................................................

3. FEATURES .....................................................................

4. SETTING & INSTALLATION ............................................. 4. 1 Unpacking ..................................................................... 4. 2 DIP Switch Setting ............................................................. 4. 3 Cable Connection .............................................................. 4. 4 Installation ..................................................................... 4. 5 Bagic Configuration of the Systerm ............................................

5. MAIN SETUP MENU ....................................................... 5. 1 Calling up the OSD Menu ...................................................... 5. 2 Main Menu .................................................................... 5. 3 Motion Setting ................................................................. 5. 4 Dome Setting .................................................................. 5. 5 Camera Setting (36x) .......................................................... 5. 6 Camera Setting (26x)........................................................... 5. 7 Light Mode .................................................................... 5. 8 Clear Data ..................................................................... 5. 9 Vector Initialize ................................................................ 5. 10 Compulsory Fan&Heater operation............................................ 5. 11 Other Quick Operating Guide ..................................................

6. SPECIFICATIONS ............................................................

7. DIMENSIONS ................................................................. 7. 1 Standard Model ................................................................ 7. 2 Optional Bracket (Vihechle bracket).............................................

8. TROUBLE SHOOTING .....................................................

Page 3: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

04

RUGG

ED IR

PTZ

CAM

ERA

05

RUGG

ED IR

PTZ

CAM

ERA

3. FEATURES

This stable and reliable design makes ideal for carapplication such as traffic monitoring,car surveillance, because it has IP66 grade, Aluminum die-casting body and Image Stabilizerfunction (only 26X zoom Series).

S pecially useful for Police car and other special application

The built-in 36X/26X optical zoom lens with auto-focus is combined with a 12X digital zoom,providing a maximum of 432X/312X zoom.

A uto-focus 36X/26X Optical Zoom

The IR cut filter is on when the camera is operatingas a color camera for precise color reproduction.With ICR, the filter is removed which allows formuch greater light sensitivity in monochrome mode.

T rue Day & Night (ICR Filter Change)

Preset : Up to 63 programmable Presets.Tour : Up to 8 programmable Tours consisting ofpresets with individual dwell time.Scan : Repeatedly pan & tilt operating betweentwo positions. (Max.4)Pattern : Up to 2 programmable Patterns memorized the PTZ movement.Alarm : Move the camera to programmed Presetposition with Alarm trigger.(Max.2)Area : Up to 2 programmable Areas display set.

Wide Range Auto functions

B uilt-in Fan & Heater

3 60˚ Endless Pan Rotation (15˚ to 270˚ Tilt Angle)

The camera IDs, camera preset numbers, presetnames, area names and camera operation statusare displayed on the monitor, allowing set up ofvarious camera functions through the OSD menuscreen.

O SD (On Screen Display)

M echanical Auto Flip

It’s builin 12 Pcs IR LED, So it provides visible distance up to 120m in dark.

L ight Function

C ompact Size

Even though this camera has built-in

26X/36X optical zoom and LED, it’s size is very compact (Refer to the 42~43 pages). So it does’t spoil beauty of city.

In manual mode, sophisticated operating ispossible at zoom in state by speed correctingfunction.

V ariable speed Pan/Tilt control

The Camera delivers clear, high quality pictureseven in backlight, by increasing exposure in darkareas while decreasing it in bright areas a corrected image with clear details results(only 36X Zoom Series).

WDR (Wide dynamic range)

2. PRECAUTIONS

Do use the camera under conditions where temperatures are within -20°C to 50°C(in continuous operation). Under high temperatures, ensure proper ventilation.

Do not install the camera in extreme temperature conditions.

Do not install or use the camera in an environment where the humidity is high.

Do not install the camera under unstable lighting conditions.

It can cause the image quality to be poor.

Severe lighting change or flicker can cause the camera to work improperly.

Never use the camera close to a gas or oil leak.

Do not disassemble the camera.

It can cause malfunctions to occur.

There are no user-serviceable parts inside it.

Do not drop the camera or subject them to physical shocks.It can cause malfunctions to occur.

Do not allow direct sunlight into the camera.It can damage CCD.

Do not expose the camera to rain or spill beverages on it.

Note

If it gets wet, wipe it dry immediately. Liquids can contain minerals that corrodethe electronic components.

If the camera is exposed to spotlight or object reflecting the strong light,smear or blooming may occur.Please check the power whether it satisfies the normal specification beforeconnecting the camera.

To prevent electric shock and risk of fire hazards.

Do not use power sources other than that specified.

Page 4: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

Before start up the camera, set the protocol, camera address and details with dip-switches referringto the follows.

Each camera must have a unique address(ID). Identacal IDs on the same line may damage the controlcurcuit caused by an electronic short.

06

RUGG

ED IR

PTZ

CAM

ERA

07

RUGG

ED IR

PTZ

CAM

ERA

4. SETTING & INSTALLATION

4. 1 Unpacking

Manual

Main Cable

Screws

Alarm Cable

1. BH 3 x 6 (Screw for base plate with camera)2. TH 3 x 6 (Screw for safety cable)

8 x 38 (Screw to fix the base plate bracket)

4PIN Plugable Terminal BlockBase plate bracket

1. 2.

4. 2 DIP Switch Setting

Open the left side of cover and set the camera

Camera ID (ADDRESS)

Ex) S/W101=0, S/W102=0, S/W103=1

Address=001

S/W103 : 1 digit of IDS/W102 : 10 digit of IDS/W101 : 100 digit of ID

S/W101 S/W102 S/W103

S/W105

FirmwareUpgradeTerminal

S/W101S/W102

S/W103

S/W106

Page 5: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

08

RUGG

ED IR

PTZ

CAM

ERA

09

RUGG

ED IR

PTZ

CAM

ERA

Data Communication

Alarm

Power Input

Video Out

4. 3. 1 Basic Diagram of Cable Connection

4. 3. 2 Video Output Connection Connect the video out (BNC) connector to the monitor or video input of DVR.

4. 3. 3 RS-485 / RS-422 Communication Connection Rugged IR PTZ camera can be remotely controlled by an external device or control system, such as a control keyboard or DVR, using RS-485 half-duplex, RS-422 duplex or simplex serial data communi -cation signals. After inserting 4pin plugable terminal block of accessory package to green port of main cable, then connect marked RX+, RX- to TX+, TX- of the RS-485 control system. If control system is RS-422, connect TX+,TX- of controller to RX+, RX- of the camera. And also connect the TX+, TX- of camera to RX+, RX- of the control device respectively. Total length of the cable for commu -nication should not exceed 1.2Km.

4. 3. 4 Alarm Connection Rugged IR PTZ camera can operate specific motion receiving external Alarm Device(Sensor)’s signal (Max 2 Alarm.) Connect the alarm cable to external Alarm Device referring to below. - Brown color line : Ground / Black & Red color lines : Alarm 1 & 2.

4. 3. 5 Power Connection - After connecting above 3 connections(Video/Data Communication/Alarm), connect the power cable finally. - Connect the power of DC 12V, 1.5A to this camera. - Use certified Class 2 power supply transformer only.

PROTOCOL

BAUDRATE

BAUDRATE

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

S/W105-3 S/W105-4

2400bps4800bps9600bps

19200bpsON

ON

ON

OFF

OFF

ON

OFF

ON

OFF

ON

S/W106-1

OFF

ON

OFF

38400bps57600bps

115200bps

Vertical FLIP

OFF

ON

S/W106-2

TOP

BOTTOM

OFF

ON

S/W106-3

NTSC

PAL

VIDEO Type

ON

OFF

S/W106-4

RS485

RS422

Data Communication

DIP switch

1. Baud rate2. Select the Video mode (Top/Bottom: Vertical FLIP)3. Select Video Type4. Data Communication (RS422/RS485)

S/W106

ONON 1. Protocol2. Protocol3. Baud rate4. Baud rate

S/W105

4. 3 Cable Connection

PROTOCOL

OFF

OFF

ONON

OFF

ON

OFFON

S/W105-1 S/W105-2

WTXWPD1.0 (PELCO-D V1.0)WPP (PELCO-P)WPD5.0 (PELCO-D V5.0)

Page 6: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

10

RUGG

ED IR

PTZ

CAM

ERA

11

RUGG

ED IR

PTZ

CAM

ERA

4. 4 Installation- The following steps of installation and connection work should be done by qualified service personnel or system installers and should confirm to all local codes.- Be sure to switch the camera off before installation is completed.- Do not install the camera near the air outlet of an air conditioner.- Before installation, set camera system with Dip-switches on the 7~8 pages.

5

Pull out the cablewhere the camera will be installed.

Connect the safety wire to the camerabase and base plate using enclosedscrews(TH 3x6).

Fix the baseplate after make holes on the ceiling.

Fix the screw(BH 3x6) after fix the camera on the ceiling.

1

1

3

2

4

5

Attached the camera base plateto the bracket base plate by using M4x8 SUS screws.

Pull out the cable from the hole of bracket base plate and connect with camera.(<--- See picture No.3)

Connect the safty wire of camera base plate to the bottom of cameraby using TH3x6 screws.(Screws are enclosed in the accessory pack)

Fix the serew(PH3x6) with the camera body and camera base plate.(Screws are enclosed in the accessory pack)

Attach the guide plate to the bracketbase by using M4x8 screws.

2

3

4. 4. 2 Installation for vehicle application To install Rugged IR PTZ Camera to Vehicle, Bracket must be needed. This bracket is provided optionally.

4. 4. 1 Typical Installation

4

Connect the maincables.

Page 7: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

12

RUGG

ED IR

PTZ

CAM

ERA

13

RUGG

ED IR

PTZ

CAM

ERA

4. 5 Basic Configuration of the System4. 4. 3 Installation for vehicle application To install Rugged IR PTZ Camera to Vehicle, Bracket must be needed. This bracket is provided optionally.

Controller

Pull out the cable from the hole of bracket base plate and connect with camra.( <--- See picture no.3)

Connect the safty wire of camera base plate to the bottom of camera by using TH3X6 screws.(Screws are enclosed in the accessory pack)

Fix the screw (PH 3x6) with the camera body and camera base plate.(Screws are enclosed in the accessory pack)

Attach the guide plate to the bracket base by using screws.( M4x8 TH / M4 SPRING W/S )

Attached the camera base plate to the bracket base plate by using M4x8 SUS screws.

2.

4.

3.

1.

5.(PH M3x6 SUS 1EA)

(TH M3x6 SUS 1EA)

(M4x8 TH SUS 7EA)

Page 8: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

5. MAIN SETUP MENU

5. 1 Calling up the OSD MenuTo get the OSD Menu, press keypad “1” and hold the “Menu” Key for approximately 3 seconds or “Press 95 + Preset” through the OSD Menu screen. It’s available to check the camera operationstatus and set up various camera functions.

5. 2 Main Menu

1 + or 95 +

Main Menu window will appear, once OSD Menu is called up.

** Move the joystick up and down to navigate through the menu items.

Push the NEAR key or move joystick to the right to select a menu item. or

MENU PRESET Quick Operating Guide

Flip : 90 +

Auto Flip ON : 93 + 3sec.

Auto Flip OFF : 94 + 3sec.

Move Center position : 93 +

Menu Start : 95 +

PRESET

PRESET

PRESET

PRESET

PRESET

MAIN MENU

< NEAR / RIGHT → SUB MENU >

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE IR LED

VECTOR INITEXIT

MOTION MENU

< NEAR / RIGHT → SUB MENU >

PRESET TOUR SCAN PATTERN ALARM AREA BACKEXIT

DOME MENU

< SEL → NEAR / RIGHT >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF SPEED BY ZOOM ONFACTORY SET BACKEXIT

FOCUS MODE AUTONEAR LIMIT AF SETTING WB SETTING AE SETTING SPECIAL

BACKCAMERA RESET

EXIT

CAMERA MENU

< NEAR / RIGHT → FOCUS MENU >

DATA CLEAR

< SEL → NEAR / RIGHT >

PRESETTOURAREAALARMSCANPATTERNBACKEXIT

NEAR

14

RUGG

ED IR

PTZ

CAM

ERA

15

RUGG

ED IR

PTZ

CAM

ERA

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INITEXIT

5. 3 Motion Setting

The Preset function is that the camera memorizes positions of the pan/tilt and zoom. This function is representative function of speed dome which can find memorized preset position just by selecting preset No. Maximum 63 Preset positions are toured in order.

5. 3. 1 Preset

Preset Quick Operating Guide

Set Preset : #1~63 + 3sec.

Go to Preset : #1~63 +

PRESET

PRESET

PRESET MENU

< NEAR / RIGHT → PRESET NO >

PRESET NO : 01 DEFINELABEL : PRESET 01POSITION : 352.0, 090.0CLEARSAVEBACKEXIT

PRESET SELECT

< SEL → NEAR / MOVE → JOYSTICK >

P01 P02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

(1) Select the Preset number P01 : Defined Preset number / 01 : Undefined Preset number

Move : Select : NEAR

MAIN MENU

< NEAR / RIGHT → SUB MENU >

MOTION MENU

< NEAR / RIGHT → SUB MENU >

PRESET TOUR SCAN PATTERN ALARM AREA BACKEXIT

Page 9: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

(4) Delete the Preset position data

PRESET MENU

< NEAR / RIGHT → DATA CLEAR >

PRESET NO : 01 DEFINELABEL : PRESET 01POSITION : 352.0, 090.0CLEARSAVEBACKEXIT

PRESET MENU

< SEL → NEAR LEFT / RIGHT >

PRESET NO : 01 DEFINELABEL : PRESET 01POSITION : 352.0, 090.0CLEAR YES NOSAVEBACKEXIT

PRESET MENU

< MOVE → NEAR / JOYSTICK >

PRESET NO : 01 DEFINELABEL : PRESET 01POSITION : 352.0, 090.0CLEARSAVEBACKEXIT

PRESET POSITION

< EXIT → FOCUS NEAR > ■ POSITION : 000.0, 000.0

(3) Define the Preset position ① Move to the set-up window

orNEAR

② Move and set the position ③ Set & Back

NEAR

PRESET MENU

< NEAR / RIGHT → LABEL EDIT >

PRESET NO : 01 DEFINELABEL : PRESET 01POSITION : 352.0, 090.0CLEARSAVEBACKEXIT

PRESET LABEL EDIT ( 01 )

< DELETE → WIDE< STORE → TELE

BACK → NEAR >MOVE → JOYSTICK >

LABEL : PRESET 01

(2) Set the Preset Label

Move : Select : or or Delete : orTELE

JOYSTICK

WIDE

JOYSTICK

It’s available to set the desired label, displayed on the executing screen of Preset.

After the label set, push NEAR button to go out.

(5) Save above setting Preset data to the memory

(6) “BACK” means it goes back one level before

(7) “EXIT” means it goes out of MENU

PRESET MENU

< NEAR / RIGHT → DATA SAVE >

PRESET NO : 01 DEFINELABEL : PRESET 01POSITION : 352.0, 090.0CLEARSAVEBACKEXIT

PRESET MENU

< NEAR / RIGHT → BACK MENU >

PRESET NO : 01 DEFINELABEL : PRESET 01POSITION : 352.0, 090.0CLEARSAVEBACKEXIT

PRESET MENU

< NEAR / RIGHT → EXIT MENU >

PRESET NO : 01 DEFINELABEL : PRESET 01POSITION : 352.0, 090.0CLEARSAVEBACKEXIT

16

RUGG

ED IR

PTZ

CAM

ERA

17

RUGG

ED IR

PTZ

CAM

ERA

Page 10: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INITEXIT

TOUR MENU

< NEAR / RIGHT → TOUR NO >

TOUR NO : 01 DEFINELABEL : TOUR 01TOUR EDITCLEARSAVEBACKEXIT

TOUR SELECT

< SEL → NEAR / MOVE → JOYSTICK >

T01 T02 03 04 05 06 07 08

(1) Select the Tour number T01 : Defined Tour number / 01 : Undefined Tour number

Move : Select : NEAR

The Tour function consists of several presets run by turn. It is also adjustable the moving speed(1~63 step) and dwell time (1~99sec). Maximum 8 Tour functions are toured in order.

5. 3. 2 Tour

Tour Quick Operating Guide

Programming : #71~78 + 3sec.

Operating : #71~78 +

PRESET

PRESET

MAIN MENU

< NEAR / RIGHT → SUB MENU >

MOTION MENU

< NEAR / RIGHT → SUB MENU >

PRESET TOUR SCAN PATTERN ALARM AREA BACKEXIT

18

RUGG

ED IR

PTZ

CAM

ERA

19

RUGG

ED IR

PTZ

CAM

ERA

(4) Delete the programmed Tour data

TOUR MENU

< NEAR / RIGHT → DATA CLEAR >

TOUR NO : 01 DEFINELABEL : TOUR 01TOUR EDITCLEARSAVEBACKEXIT

TOUR MENU

< SEL → NEAR LEFT / RIGHT >

TOUR NO : 01 DEFINELABEL : TOUR 01TOUR EDITCLEAR YES NOSAVEBACKEXIT

(3) Define the Preset position ① Move to the set-up window

orNEAR

② Move and set the position ③ Set & Back

NEAR

TOUR MENU

< NEAR / RIGHT → LABEL EDIT >

TOUR NO : 01 DEFINELABEL : TOUR 01TOUR EDITCLEARSAVEBACKEXIT

PRESET SELECT

< SEL → NEAR / MOVE → JOYSTICK >

P01 P02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

TOUR LABEL EDIT ( 01 )

< DEL → WIDE< STORE → TELE

BACK → NEAR > MOVE → JOY >

TOUR MENU

< NEAR / RIGHT → TOUR EDIT >

TOUR NO : 01 DEFINELABEL : TOUR 01TOUR EDITCLEARSAVEBACKEXIT

TOUR EDIT (01)

NO PRESET SPEED DWELL 01 ◀ 01 63 01 02 ◁ 02 63 01 03 ◁ XX XX XX 04 ◁ XX XX XX 05 ◁ XX XX XX 06 ◁ XX XX XX 07 ◁ XX XX XX 08 ◁ XX XX XX

< SEL → NEAR PRESET → LEFT >

LABEL : TOUR 01

(2) Set the Tour Label

Move : Select : or or Delete : orTELE

JOYSTICK

WIDE

JOYSTICK

It’s available to set the desired label, displayed on the executing screen of Tour.

After the label set, push NEAR button to go out.

Page 11: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

(5) Save above setting Tour data to the memory

(6) “BACK” means it goes back one level before

(7) “EXIT” means it goes out of MENU

TOUR MENU

< NEAR / RIGHT → DATA SAVE >

TOUR NO : 01 DEFINELABEL : TOUR 01TOUR EDITCLEARSAVEBACKEXIT

TOUR MENU

< NEAR / RIGHT → BACK MENU >

TOUR NO : 01 DEFINELABEL : TOUR 01TOUR EDITCLEARSAVEBACKEXIT

TOUR MENU

< NEAR / RIGHT → EXIT MENU >

TOUR NO : 01 DEFINELABEL : TOUR 01TOUR EDITCLEARSAVEBACKEXIT

20

RUGG

ED IR

PTZ

CAM

ERA

21

RUGG

ED IR

PTZ

CAM

ERA

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INITEXIT

SCAN MENU

< NEAR / RIGHT → SCAN NO >

SCAN NO : 01 DEFINELABEL : SCAN 01START PAN POSITION : XXX.XEND PAN POSITION : XXX.XMOVE SPEED : 50CLEARSAVEBACKEXIT

SCAN SELECT

< SEL → NEAR / MOVE → JOYSTICK >

S01 S02 03 04

(1) Select the Scan number S01 : Defined Scan number / 01 : Undefined Scan number

Move : Select : NEAR

The Scan function is that the camera keeps panning between programmed two pan positions. And it is also adjustable moving speed(1~63 step). Maximum 4 Scan functions are toured in order.

5. 3. 3 Scan

Scan Quick Operating Guide

Programming : #81~84 + 3sec.

Operating : #81~84 +

PRESET

PRESET

MAIN MENU

< NEAR / RIGHT → SUB MENU >

MOTION MENU

< NEAR / RIGHT → SUB MENU >

PRESET TOUR SCAN PATTERN ALARM AREA BACKEXIT

Page 12: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

22

RUGG

ED IR

PTZ

CAM

ERA

23

RUGG

ED IR

PTZ

CAM

ERA

(6) Delete the programmed Scan data

(7) Save above setting Scan data to the memory

(8) “BACK” means it goes back one level before

(9) “EXIT” means it goes out of MENU

SCAN MENU

< NEAR / FAR → TELE / WIDE >

SCAN NO : 01 UNDEFINELABEL : SCAN 01START PAN POSITION : 073.8END PAN POSITION : 111.4MOVE SPEED : 63CLEARSAVEBACKEXIT

SCANMENU

< NEAR / RIGHT → DATA CLEAR >

SCAN NO : 01 UNDEFINELABEL : SCAN 01START PAN POSITION : 073.8END PAN POSITION : 111.4MOVE SPEED : 63CLEARSAVEBACKEXIT

SCANMENU

< SEL → NEAR LEFT / RIGHT >

SCAN NO : 01 UNDEFINELABEL : SCAN 01START PAN POSITION : 073.8END PAN POSITION : 111.4MOVE SPEED : 63CLEAR YES NOSAVEBACKEXIT

SCAN MENU

< NEAR / RIGHT → DATA SAVE >

SCAN NO : 01 UNDEFINELABEL : SCAN 01START PAN POSITION : 073.8END PAN POSITION : 111.4MOVE SPEED : 63CLEARSAVEBACKEXIT

SCAN MENU

< NEAR / RIGHT → BACK MENU >

SCAN NO : 01 UNDEFINELABEL : SCAN 01START PAN POSITION : 073.8END PAN POSITION : 111.4MOVE SPEED : 63CLEARSAVEBACKEXIT

SCAN MENU

< NEAR / RIGHT → EXIT MENU >

SCAN NO : 01 UNDEFINELABEL : SCAN 01START PAN POSITION : 073.8END PAN POSITION : 111.4MOVE SPEED : 63CLEARSAVEBACKEXIT

(5) Set the Scan speed

Increase : or

Decrease : or

TELE

JOYSTICK

WIDE

JOYSTICK

SCAN MENU

< MOVE → NEAR / JOYSTICK >

SCAN LABEL EDIT (01)

< EXIT → FOCUS NEAR > ■ POSITION : 000.0, 000.0

(3) Define the Start pan position ① Move to the set-up window

orNEAR

② Move and set the position ③ Go back

NEAR

SCAN MENU

< NEAR / RIGHT → LABEL EDIT >

SCAN NO : 01 DEFINELABEL : SCAN 01START PAN POSITION : XXX.XEND PAN POSITION : XXX.XMOVE SPEED : 50CLEARSAVEBACKEXIT

SCAN NO : 01 DEFINELABEL : SCAN 01START PAN POSITION : 073.8END PAN POSITION : XXX.XMOVE SPEED : 50CLEARSAVEBACKEXIT

SCAN LABEL EDIT ( 01 )

< DEL → WIDE< STORE → TELE

BACK → NEAR > MOVE → JOY >

LABEL : SCAN 01

(2) Set the Scan Label

Move : Select : or or Delete : orTELE

JOYSTICK

WIDE

JOYSTICK

(4) Define the End pan position ① Move to the set-up window

orNEAR

② Move and set the position ③ Go back

NEAR

SCAN MENU

< MOVE → NEAR / JOYSTICK > ■ POSITION : 000.0, 000.0

SCAN END PAN POSITION

SCAN NO : 01 UNDEFINELABEL : SCAN 01START PAN POSITION : 073.8END PAN POSITION : 000.0MOVE SPEED : 50CLEARSAVEBACKEXIT

< EXIT → FOCUS NEAR >

It’s available to set the desired label, displayed on the executing screen of Scan.

After the label set, push NEAR button to go out.

Page 13: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INITEXIT

PATTERN MENU

< NEAR / RIGHT → PATTERN NO >

PATTERN NO : 01 DEFINELABEL : PATTERN 01RECORD 070.8, 044.3PLAY 070.8, 044.3CLEARBACKEXIT

PATTERN SELECT

< SEL → NEAR / MOVE → JOYSTICK >

PAT01 02

(1) Select the Pattern number PAT01 : Defined Pattern number / 01 : Undefined Pattern number

Move : Select : NEAR

The Pattern function memorizes User’s random moving path and zoom ratio. Total recording timelimit is 90sec and maximum 2 Pattern functions are toured in order.

5. 3. 4 Pattern

Tour Quick Operating Guide

Programming : #91~92 + 3sec.

Operating : #91~92 +

PRESET

PRESET

MAIN MENU

< NEAR / RIGHT → SUB MENU >

MOTION MENU

< NEAR / RIGHT → SUB MENU >

PRESET TOUR SCAN PATTERN ALARM AREA BACKEXIT

24

RUGG

ED IR

PTZ

CAM

ERA

25

RUGG

ED IR

PTZ

CAM

ERA

(4) Play back the recorded Pattern data

PATTERN MENU

< NEAR / RIGHT → PATTERN PLAY >

EXIT

PATTERN NO : 01 DEFINELABEL : PATTERN 01RECORD 070.8, 044.3PLAY 070.8, 044.3CLEARBACKEXIT

■ PATTERN PLAY : 000.0, 000.0 12/90

PATTERN RECORD SAVE

< EXIT → FOCUS NEAR >

(3) Record and Save the User’s random Pattern data ① Select the “Record save”

orNEAR

② Move and record the pattern ③ Set & Back

NEAR

PATTERN MENU

< NEAR / RIGHT → LABEL EDIT >

PATTERN NO : 01 DEFINELABEL : PATTERN 01RECORD 070.8, 044.3PLAY 070.8, 044.3CLEARBACKEXIT

PATTERN LABEL EDIT ( 01 )

< DEL → WIDE< STORE → TELE

BACK → NEAR > MOVE → JOY >

LABEL : PATTERN 01

PATTERN MENU

< NEAR / RIGHT → PATTERN REC >

PATTERN NO : 01 DEFINELABEL : PATTERN 01RECORD 070.8, 044.3PLAY 070.8, 044.3CLEARBACKEXIT

■ REC : 000.0, 000.0 12/90

PATTERN RECORD SAVE

< EXIT → FOCUS NEAR >

(2) Set the Pattern Label

Move : Select : or or Delete : orTELE

JOYSTICK

WIDE

JOYSTICK

It’s available to set the desired label, displayed on the executing screen of Pattern.

After the label set, push NEAR button to go out.

Page 14: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

(5) Delete the programmed Pattern data

(6) “BACK” means it goes back one level before

(7) “EXIT” means it goes out of MENU

PATTERN MENU

< NEAR / RIGHT → DATA CLEAR >

PATTERN MENU

< NEAR / RIGHT → BACK MENU >

PATTERN MENU

< NEAR / RIGHT → EXIT MENU >

PATTERN NO : 01 DEFINELABEL : PATTERN 01RECORD 070.8, 044.3PLAY 070.8, 044.3CLEARBACKEXIT

PATTERN NO : 01 DEFINELABEL : PATTERN 01RECORD 070.8, 044.3PLAY 070.8, 044.3CLEARBACKEXIT

PATTERN NO : 01 DEFINELABEL : PATTERN 01RECORD 070.8, 044.3PLAY 070.8, 044.3CLEARBACKEXIT

26

RUGG

ED IR

PTZ

CAM

ERA

27

RUGG

ED IR

PTZ

CAM

ERA

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INITEXIT

ALARM MENU

< NEAR / RIGHT → LABEL EDIT >

ALARM MENU

< NEAR / RIGHT → ALARM NO >

ALARM NO : 01 DEFINELABEL : PRESET NO : XXCLEARSAVEBACKEXIT

ALARM NO : 01 DEFINELABEL : PRESET NO : XXCLEARSAVEBACKEXIT

ALARM SELECT

< SEL → NEAR / MOVE → JOYSTICK >

ALARM 01 02

(1) Select the Alarm number Alarm 01 : Defined Alarm number / 01 : Undefined Alarm number

Move : Select : NEAR

ALARM LABEL EDIT ( 01 )

< DELETE → WIDE< STORE → TELE

BACK → NEAR >MOVE → JOYSTICK >

LABEL :

(2) Set the Alarm Label

Move : Select : or or Delete : orTELE

JOYSTICK

WIDE

JOYSTICK

Alarm function is that the camera move to the programmed Preset position by Alarm trigger.Maximum 2 Alarm functions are toured in order.

5. 3. 5 Alarm

MAIN MENU

< NEAR / RIGHT → SUB MENU >

MOTION MENU

< NEAR / RIGHT → SUB MENU >

PRESET TOUR SCAN PATTERN ALARM AREA BACKEXIT

It’s available to set the desired label, displayed on the executing screen of Alarm.

After the label set, push NEAR button to go out.

Page 15: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

PRESET SELECT

< SEL → NEAR / MOVE → JOYSTICK >

P01 P02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

ALARM MENU

(3) Define the Preset position with Alarm trigger ① Select the “Preset No”

orNEAR

② Move and set the position ③ Set & Back

NEAR

(4) Delete the Preset position data

(5) Save above programmed Alarm position data to the memory

(6) “BACK” means it goes back one level before (7) “EXIT” means it goes out of MENU

< NEAR / RIGHT → PRESET NO >

ALARM MENU

< NEAR / RIGHT → DATA CLEAR >

ALARM MENU

< NEAR / RIGHT → BACK MENU >

ALARM MENU

< NEAR / RIGHT → EXIT MENU >

ALARM NO : 01 DEFINELABEL : PRESET NO : 01CLEARSAVEBACKEXIT

ALARM NO : 01 DEFINELABEL : PRESET NO : 01CLEARSAVEBACKEXIT

ALARM NO : 01 DEFINELABEL : PRESET NO : 01CLEARSAVEBACKEXIT

ALARM MENU

< NEAR / RIGHT → DATA CLEAR >

ALARM NO : 01 DEFINELABEL : PRESET NO : 01CLEARSAVEBACKEXIT

ALARM MENU

< SEL → NEAL LEFT / RIGHT >

ALARM NO : 01 DEFINELABEL : PRESET NO : 01CLEAR YES NOSAVEBACKEXIT

ALARM NO : 01 DEFINELABEL : PRESET NO : 01CLEARSAVEBACKEXIT

28

RUGG

ED IR

PTZ

CAM

ERA

29

RUGG

ED IR

PTZ

CAM

ERA

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INITEXIT

AREA MENU

< NEAR / RIGHT → LABEL EDIT >

AREA MENU

< NEAR / RIGHT → AREA NO >

AREA NO : 01 UNDEFINELABEL : START PAN POS : XXX.XSTOP PAN POS : XXX.XCLEARSAVEBACKEXIT

AREA NO : 01 UNDEFINELABEL : START PAN POS : XXX.XSTOP PAN POS : XXX.XCLEARSAVEBACKEXIT

AREA SELECT

< SEL → NEAR / MOVE → JOYSTICK >

AR 01 02 03 04

(1) Select the Area number AR 01 : Defined Area number / 01 : Undefined Area number

Move : Select : NEAR

AREA LABEL EDIT ( 01 )

< DELETE → WIDE< STORE → TELE

BACK → NEAR >MOVE → JOYSTICK >

LABEL :

(2) Set the Area Label

Move : Select : or or Delete : orTELE

JOYSTICK

WIDE

JOYSTICK

The Area function is that display the Area name between two programmed pan positions. Maximum 4 Area functions are toured in order.

5. 3. 6 Area

MAIN MENU

< NEAR / RIGHT → SUB MENU >

MOTION MENU

< NEAR / RIGHT → SUB MENU >

PRESET TOUR SCAN PATTERN ALARM AREA BACKEXIT

It’s available to set the desired label, displayed on the executing screen of Area.

After the label set, push NEAR button to go out.

Page 16: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

AREA START PAN POSITION

< EXIT → FOCUS NEAR > ■ POSITION : 000.0

AREA STOP PAN POSITION

< EXIT → FOCUS NEAR > ■ POSITION : 000.0

(3) Define the Start pan position ① Select the “Start Pan Position”

orNEAR

② Move and set the position ③ Set & Back

NEAR

(4) Define the Stop pan position ① Select the “Start Pan Position”

orNEAR

② Move and set the position ③ Set & Back

NEAR

(5) Delete the programmed Area display data

** Only pan position is adjustable, becaue tilt position is fixed when “Start Pan Position” is set.

AREA MENU

AREA NO : 01 UNDEFINELABEL : START PAN POS : XXX.XSTOP PAN POS : XXX.XCLEARSAVEBACKEXIT

< MOVE → NEAL / JOYSTICK >

AREA NO : 01 UNDEFINELABEL : START PAN POS : XXX.XSTOP PAN POS : XXX.XCLEARSAVEBACKEXIT

< NEAR / RIGHT → DATA CLEAR >

AREA NO : 01 UNDEFINELABEL : START PAN POS : XXX.XSTOP PAN POS : XXX.XCLEAR YES NOSAVEBACKEXIT

< SEL → NEAL LEFT / RIGHT >

AREA MENU

AREA NO : 01 UNDEFINELABEL : START PAN POS : XXX.XSTOP PAN POS : XXX.XCLEARSAVEBACKEXIT

AREA MENU

< MOVE → NEAL / JOYSTICK >

30

RUGG

ED IR

PTZ

CAM

ERA

31

RUGG

ED IR

PTZ

CAM

ERA

(6) Save above setting Area display data to the memory

(7) “BACK” means it goes back one level before

(8) “EXIT” means it goes out of MENU

AREA NO : 01 UNDEFINELABEL : START PAN POS : XXX.XSTOP PAN POS : XXX.XCLEARSAVEBACKEXIT

AREA MENU

< NEAR / RIGHT → DATA SAVE >

AREA NO : 01 UNDEFINELABEL : START PAN POS : XXX.XSTOP PAN POS : XXX.XCLEARSAVEBACKEXIT

AREA MENU

< NEAR / RIGHT → BACK MENU >

AREA NO : 01 UNDEFINELABEL : START PAN POS : XXX.XSTOP PAN POS : XXX.XCLEARSAVEBACKEXIT

AREA MENU

< NEAR / RIGHT → BACK MENU >

Page 17: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

32

RUGG

ED IR

PTZ

CAM

ERA

33

RUGG

ED IR

PTZ

CAM

ERA

PRESET SELECT

< SEL → NEAR / MOVE → JOYSTICK >

P01 P02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

DOME MENU

< SEL → NEAR / RIGHT >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF

FACTORY SET BACKEXIT

DOME MENU

< SEL → NEAR / RIGHT >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF

FACTORY SET BACKEXIT

SPEED BY ZOOM ON SPEED BY ZOOM ON

PARK MENU

< NEAR / RIGHT → PRESET NO >

PRESET NUMBER : 01PARK TIME (MIN) 01CLEARSAVEBACK

PARK MENU

< SELECT → NEAR / RIGHT >

PRESET NUMBER : 01PARK TIME (MIN) 01CLEARSAVEBACK

DOME MENU

< NEAR / RIGHT → SUB MENU >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF

FACTORY SET BACKEXIT

SPEED BY ZOOM ON

5. 4. 4 PARK ACTION The camera move back to the programmed Preset position after the set time.

or NEAR

5. 4. 3 Power Up Action ON/OFF Set When this function is ON, the camera memorize the latest action and restore it from sudden power failure.

After the label set, push NEAR button to go out.

(1) Set the Preset number

(2) Park Time Set (OFF, 01~99min)

select : or Set ON : Set OFF :NEAR NEAR

5. 4 Dome Setting

DOME MENU

< SEL → NEAR / RIGHT >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF SPEED BY ZOOM ONFACTORY SET BACKEXIT

DOME MENU

< SEL → NEAR / RIGHT >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF SPEED BY ZOOM ONFACTORY SET BACKEXIT

DOME MENU

< SEL → NEAR UP / DOWN >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF SPEED BY ZOOM ONFACTORY SET BACKEXIT

5. 4. 2 Auto Filp ON/OFF Set The tilt angle is extended to 90˚ when this function is ON.

select : or Set ON : Set OFF :NEAR

TITLE EDIT

< DEL → WIDE< STORE → TELE

BACK → NEAR > MOVE → JOY >

LABEL :

5. 4. 1 Set the Dome camera title

Move : Select : or or Delete : orTELE

JOYSTICK

WIDE

JOYSTICK

MAIN MENU

< NEAR / RIGHT → SUB MENU >

CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INITEXIT

MOTION SETTING DOME SETTING

It’s available to set the desired camera title.

After the label set, push NEAR button to go out.

Pan, Tilt, Zoom motion is adjustable in the “Dome Setting” Menu.

Page 18: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

DOME MENU

< NEAR / RIGHT → SUB MENU >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF

FACTORY SET BACKEXIT

DISPLAY ON/OFF MENU

< SEL → NEAR / RIGHT >

TITLE : ONPRESET : ONTOUR : ONAREA : ONALARM : ON

PATTERN : ONPOSITION : ONBACK

SPEED BY ZOOM ON SCAN : ON

5. 4. 5 Display ON/OFF Set When this function is ON, the camera memorize the latest action and restore it from sudden power shut-down.

After the label set, push NEAR button to go out.

select : or Set ON : Set OFF :NEAR NEAR

PARK MENU

< NEAR / RIGHT → DATA CLEAR >

PRESET NUMBER : 01PARK TIME (MIN) 01CLEARSAVEBACK

PARK MENU

< SEL → NEAR LEFT / RIGHT >

PRESET NUMBER : 01PARK TIME (MIN) 01CLEAR YES , NOSAVEBACK

PARK MENU

< NEAR / RIGHT → DATA SAVE >

PRESET NUMBER : 01PARK TIME (MIN) 01CLEARSAVEBACK

(3) Delete the programmed Park Action data

(4) Save above Park Action data to the memory

PARK MENU

< NEAR / RIGHT → BACK MENU >

PRESET NUMBER : 01PARK TIME (MIN) 01CLEARSAVEBACK

(5) “BACK” means it goes back one level before

34

RUGG

ED IR

PTZ

CAM

ERA

35

RUGG

ED IR

PTZ

CAM

ERA

DOME MENU

< SEL → NEAR / RIGHT >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF

FACTORY SET BACKEXIT

SPEED BY ZOOM ON

5. 4. 6 Speed By Zoom ON/OFF Set When this function is ON, the pan/tilt speed is inversely adjusted to the zoom ratio.

After the label set, push NEAR button to go out.

select : or Set ON : Set OFF :NEAR NEAR

DOME MENU

< NEAL / RIGHT → SUB MENU >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF

FACTORY SET BACKEXIT

DOME MENU

< SEL → NEAR LEFT / RIGHT >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF

FACTORY SET BACKEXIT

SPEED BY ZOOM ON SPEED BY ZOOM ON

DOME MENU

< NEAR / RIGHT BACK MENU >

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF

FACTORY SET BACKEXIT

DOME MENU

TITLE SET : AUTO FLIP ONPOWER UP ACTION ONPARK ACTION DISPLAY ON/OFF

FACTORY SET BACKEXIT

SPEED BY ZOOM ON

SPEED BY ZOOM ON

5. 4. 7 Factory Set Restore all of setting value to the factory default.

All of existing setting value would be erased.

5. 4. 8 “BACK” means it goes back one level before

< NEAL / RIGHT → EXIT MENU >

5. 4. 9 “EXIT” means it goes out of MENU

Page 19: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

select : or Set ON : Set OFF :NEAR NEAR

36

RUGG

ED IR

PTZ

CAM

ERA

37

RUGG

ED IR

PTZ

CAM

ERA

5. 5 Camera Setting (36x)

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Set the auto focuse mode

Set the sensitivity of focus

1) FOCUS MODE SETTING

2) WHITE BALANCE SETTING

AUTO: The camera adjusts the focus automatically while monitoring the screen continuously in the auto mode. In the auto focusing mode, zoom key operation is not recognized as the input of the focus key.One Push: It will be focused in about 5 seconds after zooming, panning, and return to MANUAL mode automatically. This is for focusing accurately after zooming.Manual: In the manual mode, users can adjust the camera focus manually.

Infinity: infinity focus is the state where a lens forms an image of an object an infinite distance away. This corresponds to the point of focus for parallel rays.

White balance setting is a function revising color temperature to resolve the problem that screen’s colors change by the color temperature’s difference according to time.

RED GAIN: Adjust red color level from 0~255. (Standard level is 025)BLUE GAIN: Adjust blue color level from 0~255. (Standard level is 025)

WB MODE: Set the color depend on white balacne.

WB MODE : Select AUTO, INDOOR, OUTDOOR ONEPUSH, ATW and MANUAL

EXIT

MAIN MENU

< NEAR / RIGHT → SUB MENU >

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INIT

CAMERA MENU

< NEAL / RIGHT → FOCUS MODE >

- FOCUS MODE

FOCUS MODEAF MODEAF SENSITIVITYBACK

: AUTO: NORMAL: NORMAL

CAMERA MENU

< NEAL / RIGHT → AFMODE SEL >

- AF MODE

FOCUS MODEAF MODEAF SENSITIVITYBACK

: AUTO: NORMAL: NORMAL

CAMERA MENU

< NEAL / RIGHT → AFSEN SEL >

- SENSITIVITY

FOCUS MODEAF MODEAF SENSITIVITYBACK

: AUTO: NORMAL: NORMAL▷

CAMERA MENU

< NEAL / RIGHT → WHITE BAR >

FOCUS MODE WB SETTINGAE SETTINGICR MODETEMP MODESPECIALCAMERA RESETBACKEXIT

CAMERA MENU

< NEAL / RIGHT → WBMODE SEL >

WB MODE : ATWRED GAIN : xxxBLUE GAIN: xxxBACK

- WB MODE

CAMERA MENU

< NEAL / RIGHT → R GAIN SEL >

WB MODE : MANUALRED GAIN : 025BLUE GAIN : 025BACK

- RED, BLUE MODE

CAMERA MENU

< NEAL / RIGHT → B GAIN SEL >

WB MODE : MANUALRED GAIN : 025BLUE GAIN : 025BACK

Camera menu is subject to be changed without prior notice to upgrade and quality increase. We may use slip sheet for the change. Please check the camera version and the slip sheet if the camera menu and this manual menu is not matched.

Page 20: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

38

RUGG

ED IR

PTZ

CAM

ERA

39

RUGG

ED IR

PTZ

CAM

ERA

3) AE SETTING

AE setting is a function adjusting shutter speed according to subject’s brightness to get standard amount of exposed light.

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select AUTO,MANUAL,SHUTTER and IRIS .

If you set ON in the EXPO MODE, you can control this level. ( -10.5dB ~ 10.5dB, changed by 1.5dB)

CAMERA MENU

< NEAL / RIGHT → AEMODE SEL >

AE MODE : AUTO EXPOSURE : 0dBSLOW SHUTTER : AUTOSHUTER : AUTOIRIS LEVEL : AUTOGAIN : XXBACK

CAMERA MENU

< NEAL / RIGHT → AEMODE SEL>

FOCUS MODE WB SETTINGAE SETTINGICR MODETEMP MODESPECIALCAMERA RESETBACKEXIT

- AE MODE

CAMERA MENU

< NEAL / RIGHT → EXP SEL >

AE MODE : AUTO EXPOSURE : 0dBSLOW SHUTTER : AUTOSHUTER : AUTOIRIS LEVEL : AUTOGAIN : XXBACK

- EXPOSURE

CAMERA MENU

< NEAL / RIGHT → SLOWSHUTTER >

AE MODE : AUTO EXPOSURE : 0dBSLOW SHUTTER : AUTOSHUTER : AUTOIRIS LEVEL : AUTOGAIN : 01BACK

- SLOW SHUTTER

AUTO,MANUAL Setting

CAMERA MENU

< NEAL / RIGHT → SHUTTER SEL >

AE MODE : AUTO EXPOSURE : 0dBSLOW SHUTTER : AUTOSHUTER : AUTOIRIS LEVEL : AUTOGAIN : XXBACK

- SHUTTER

CAMERA MENU

< NEAL / RIGHT → IRIS LEVEL >

AE MODE : AUTO EXPOSURE : 0dBSLOW SHUTTER : AUTOSHUTER : AUTOIRIS LEVEL : F1.6GAIN : 01BACK

- IRIS LEVEL

CAMERA MENU

< NEAL / RIGHT → GAIN SEL >

AE MODE : AUTO EXPOSURE : 0dBSLOW SHUTTER : AUTOSHUTER : 1/60IRIS LEVEL : AUTOGAIN : 01BACK

- GAIN

If you set IRIS in the AE MODE, you can set the IRIS level.

If you set MANUAL, IRIS and SHUTTER in the AE MODE, you can set the GAIN for brighter image from 00~14dB.

If you set SHUTTER in the AE MODE, you can control image brightness by adjusting shutter speed.NTSC: x8, x16, x32, x64, x128, x512, 1/100000, 1/50000,1/20000, 1/10000, 1/5000, 1/2000, 1/1500, 1/1000, 1/500,1/250, 1/180, 1/100, 1/90, 1/60, 1/30, 1/15PAL: x512, x128, x64, x32, x16, x8, x4, x2, 1/50, 1/801/120, 1/150, 1/250, 1/500, 1/1000, 1/1500, 1/2000,1/5000, 1/10000, 1/20000, 1/50000, 1/100000

Page 21: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

40

RUGG

ED IR

PTZ

CAM

ERA

41

RUGG

ED IR

PTZ

CAM

ERA

Set ICR Mode

Set the standard of brightness by setting DAY/NIGHTDAY: IR OFF NIGHT: IR ON

Set the brightness level. (from 00 to 16 steps)

Set the lux to change DAY/NIGHT.

Set the lux to change NIGHT/DAY.

4) ICR MODE SETTING

CAMERA MENU

< NEAL / RIGHT → ICR MODE>

FOCUS MODE WB SETTINGAE SETTINGICR MODETEMP MODESPECIALCAMERA RESETBACKEXIT

-DAY/NIGHT

- DAY/LIGHT LEVEL

- LIGHT/DAY LEVEL

-THRESHOLD

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

CAMERA MENU

< NEAL / RIGHT → DAY/NIGHT >

DAY/NIGHT : DAYTHRESHOLD : 10DAY NIGHT LVL : 2.0LUXNIGHT DAY LVL : 4.0LUXBACK

CAMERA MENU

< NEAL / RIGHT → THRESHOLD >

DAY/NIGHT : DAYTHRESHOLD : 10DAY NIGHT LVL : 2.0LUXNIGHT DAY LVL : 4.0LUXBACK

CAMERA MENU

< NEAL / RIGHT → D▷N LEVEL >

DAY/NIGHT : DAYTHRESHOLD : 10DAY NIGHT LVL : 2.0LUXNIGHT DAY LVL : 4.0LUXBACK

CAMERA MENU

< NEAL / RIGHT → N▷D LEVEL >

DAY/NIGHT : DAYTHRESHOLD : 10DAY NIGHT LVL : 2.0LUXNIGHT DAY LVL : 4.0LUXBACK

Page 22: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

42

RUGG

ED IR

PTZ

CAM

ERA

43

RUGG

ED IR

PTZ

CAM

ERA

- HEATER ON TEMP

- HEATER ON TIME

- HEATER OFF TEMP

CAMERA MENU

< NEAL / RIGHT → TEMP MODE>

FOCUS MODE WB SETTINGAE SETTINGICR MODETEMP MODESPECIALCAMERA RESETBACKEXIT

CAMERA MENU

< NEAL / RIGHT → HEATER ON >

HEATER ON TEMP : 15cHEATER ON TIME : 30MINHEATER OFF TIME : 20cBACK

CURRENT TEMP : 32.8c

CAMERA MENU

< NEAL / RIGHT → ON TIME >

HEATER ON TEMP : 15cHEATER ON TIME : 30MINHEATER OFF TIME : 20cBACK

CURRENT TEMP : 32.8c

CAMERA MENU

< NEAL / RIGHT → HEATER OFF >

HEATER ON TEMP : 15cHEATER ON TIME : 30MINHEATER OFF TIME : 20cBACK

CURRENT TEMP : 32.8c

5) TEMP MODE SETTING

Set the operating temperature of the heater.

Set the operating time of the heater.

Set the temerature of heater OFF.

It shows you the current temperature and you can also set the value manually. The compulsory Fan & Heater operation is a useful function to remove humidity.(Select the operating time of Heater from 10 to 60 min.)

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

6) SPECIAL SETTING

- D-ZOOM

CAMERA MENU

< NEAL / RIGHT → SPECIAL SEL>

FOCUS MODE WB SETTINGAE SETTINGICR MODETEMP MODESPECIALCAMERA RESETBACKEXIT

CAMERA MENU

< NEAL / RIGHT → DZOOM SEL>

D-ZOOMAPERTURE GAIN MIRROR MODE PRESET FREEZE BACK LIGHT WDR ON /OFF STABILIZERDNR LEVEL BACK

: OFF: 07: OFF: OFF: OFF: OFF: OFF: AUTO

Decide using of digital zoom function.D-ZOOM: ON/ OFF

- APERTURE GAIN

CAMERA MENU

< NEAL / RIGHT → APERTURE>

D-ZOOMAPERTURE GAIN MIRROR MODE PRESET FREEZE BACK LIGHT WDR ON /OFF STABILIZERDNR LEVEL BACK

: ON: 07: OFF: OFF: OFF: OFF: OFF: AUTO

Select aperture gain.(00 ~ 14)

- MIRROR MODE

CAMERA MENU

< NEAL / RIGHT → MIRROR MODE >

D-ZOOMAPERTURE GAIN MIRROR MODE PRESET FREEZE BACK LIGHT WDR ON /OFF STABILIZERDNR LEVEL BACK

: ON: 07: OFF: OFF: OFF: OFF: OFF: AUTO

OSD reverse function (ON/OFF)

In the Special menu, it’s available to set special functionof the camera

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Page 23: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

44

RUGG

ED IR

PTZ

CAM

ERA

45

RUGG

ED IR

PTZ

CAM

ERA

- PRESET FREEZE

CAMERA MENU

< NEAL / RIGHT → PSET FREEZE >

D-ZOOMAPERTURE GAIN MIRROR MODE PRESET FREEZE BACK LIGHT WDR ON /OFF STABILIZERDNR LEVEL BACK

: ON: 07: OFF: OFF: OFF: OFF: OFF: AUTO

The screen is stopped while the camera is operating presetfuntion.

- BACK LIGHT

CAMERA MENU

< NEAL / RIGHT → BACK LIGHT >

D-ZOOMAPERTURE GAIN MIRROR MODE PRESET FREEZE BACK LIGHT WDR ON /OFF STABILIZERDNR LEVEL BACK

: ON: 07: OFF: OFF: OFF: OFF: OFF: AUTO

Select ON/OFF in the BACK LIGHT function.

- WDR ON /OFF

CAMERA MENU

< NEAL / RIGHT → WDR ON /OFF >

D-ZOOMAPERTURE GAIN MIRROR MODE PRESET FREEZE BACK LIGHT WDR ON /OFF STABILIZERDNR LEVEL BACK

: ON: 07: OFF: OFF: OFF: OFF: OFF: AUTO

Select ON or OFF

- STABILIZER

CAMERA MENU

< NEAL / RIGHT → STABILIZER >

D-ZOOMAPERTURE GAIN MIRROR MODE PRESET FREEZE BACK LIGHT WDR ON /OFF STABILIZERDNR LEVEL BACK

: ON: 07: OFF: OFF: OFF: OFF: OFF: AUTO

Select ON or OFF

- DNR LEVEL

CAMERA MENU

< NEAL / RIGHT → DNR LEVEL >

D-ZOOMAPERTURE GAIN MIRROR MODE PRESET FREEZE BACK LIGHT WDR ON /OFF STABILIZERDNR LEVEL BACK

: ON: 07: OFF: OFF: OFF: OFF: OFF: AUTO

Select the DNR level from AUTO, 1~10 and OFF.

Make initialize the setting value which is set in CAMERA MENU.Select YES or NO

CAMERA MENU

< NEAL / RIGHT → INITIALIZE>

FOCUS MODE WB SETTINGAE SETTINGICR MODETEMP MODESPECIALCAMERA RESETBACKEXIT

7) CAMERA RESET

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Select : or Set ON :

Set OFF :

NEAR

NEAR

Page 24: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

46

RUGG

ED IR

PTZ

CAM

ERA

47

RUGG

ED IR

PTZ

CAM

ERA

5. 6 Camera Setting (26x)

CAMERA MENU

< NEAL / RIGHT → FOCUS MODE >

FOCUS MODE AUTONEAR LIMIT AF SETTING WB SETTING AE SETTING SPECIAL CAMERA RESET BACKEXIT

CAMERA MENU

< NEAL / RIGHT → NEAL LIMIT >

FOCUS MODE NEAR LIMIT 9.5cmAF SETTING WB SETTING AE SETTING SPECIAL CAMERA RESET BACKEXIT

CAMERA MENU

< NEAL / RIGHT → AF SETTING >

FOCUS MODE NEAR LIMIT AF SETTING WB SETTING AE SETTING SPECIAL CAMERA RESET BACKEXIT

CAMERA MENU

< NEAL / RIGHT → AF MODE >

AF MODE : NORMALAF SENSITIVITY : NORMALBACK

5. 6. 2 Near Limit This function is available to fix shortest distance for Auto Focus. (Min : 1cm, Max : 20m/over)

5. 6. 1 Focus Mode Set the camera focus mode (Auto, Push Auto, Manual, Auto manual, One-Push)

5. 6. 3 AF(Auto Focus) Setting This function is available for AF Mode and AF Sensitivity.

MAIN MENU

< NEAR / RIGHT → SUB MENU >

CLEAT DATA LIGHT MODE

VECTOR INITEXIT

MOTION SETTING DOME SETTING CAMERA SETTING

or

PRESET95 +

MENU1 +

5. 6. 4 WB(White Balance) Setting White balance setting is a function revising color temperature to resolve the problem that screen’s colors change by the color temperature’s difference arrcording to time.There’re Auto, Push Auto, Manual WB modes, and in manual mode. RED(0~255) and BLUE(0~255) level adjustment is available only in Manual mode.

CAMERA MENU

< NEAL / RIGHT → WHITE BAL >

FOCUS MODE NEAR LIMIT AF SETTING WB SETTING AE SETTING SPECIAL CAMERA RESET BACKEXIT

CAMERA MENU

< NEAL / RIGHT >

WB MODE : AUTORED GAIN : XXXBLUE GAIN : XXXBACK

5. 6. 5 AE(Automatic Exposure) Setting AE Setting is a fumction adusting shutter speed according to subject’s brightness to get standard amout of exposed light. it’s availble to Set the Exposure mode(Auto, Manual) and shutter, lris, Bright level.

CAMERA MENU

< NEAL / RIGHT → SHARPNESS SETTING >

FOCUS MODE NEAR LIMIT AF SETTING WB SETTING AE SETTING SPECIAL CAMERA RESET BACKEXIT

CAMERA MENU

< NEAL / RIGHT → WHITE BALANCE SETTING >

AE MODE : FULL AUTOEXPOSURE : -4.5dbSLOW SHUTTER : AUTOSHUTTER : AUTOIRIS LEVEL : AUTOBRIGHT LEVEL : XXGAI : XXBACK

5. 6. 6 Special This function is for Digital Zoom, Preset Freese, BACK LIGHT, ICR MODE, TEMP MODE, MIRROR and STABILIZER.

** “*STABILIZER” : This fuction is changed according to cameras. (26X zoom camera includes image stabilzer, and 36X zoom camera includes WDR Funtion.)

CAMERA MENU

< NEAL / RIGHT → SPECIAL SET >

FOCUS MODE NEAR LIMIT AF SETTING WB SETTING AE SETTING SPECIAL CAMERA RESET BACKEXIT

CAMERA MENU

< NEAL / RIGHT → DZOOM ON/OFF >

DZOOM ON/OFF : ONPRESET PREEZE : ONBACK LIGHT : ON

TEMP MODE : ICR MODE : ON

STABILIZER : ONBACK

MIRROR : OFF

5. 6. 7 “Camera Reset” is to restore the camera setting value as factory default

5. 6. 8 “BACK” is to go back one level before 5. 5. 9 “EXIT” is to go out of MENU

CAMERA MENU

< NEAL / RIGHT → INITIALIZE >

FOCUS MODE NEAR LIMIT AF SETTING WB SETTING AE SETTING SPECIAL CAMERA RESET YES NOBACKEXIT

CAMERA MENU

FOCUS MODE NEAR LIMIT AF SETTING WB SETTING AE SETTING SPECIAL CAMERA RESET BACKEXIT

CAMERA MENU

FOCUS MODE NEAR LIMIT AF SETTING WB SETTING AE SETTING SPECIAL CAMERA RESET BACKEXIT

< NEAR / RIGHT → BACK MENU > < NEAR / RIGHT → EXIT MENU >

Page 25: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

48

RUGG

ED IR

PTZ

CAM

ERA

49

RUGG

ED IR

PTZ

CAM

ERA

5. 7 Light Mode

5. 8 Clear DataClear the memorized motion data in the PTZ camera - Preset, Tour, Area, Alarm, Scan, Pattern

MAIN MENU

< NEAR / RIGHT → SUB MENU >

PATTERN

MAIN MENU

< SEL → NEAR / RIGHT >

PRESETTOUR

AREAALARM

SCAN

EXITBACK

Set the LIGHT MODE (IR LED, WHITE LED)

5. 7. 1 IR LED Model

EXIT

MAIN MENU

< NEAR / RIGHT → SUB MENU >

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INIT

MAIN MENU

< SEL → NEAR / RIGHT >

IR LEDWHITE LED

EXIT

MAIN MENU

< NEAR / RIGHT → SUB MENU >

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INIT

EXIT

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INIT

MAIN MENU

< SEL → NEAR / RIGHT >

IR LEDWHITE LED

5. 7. 2 WHITE LED Model *Only White LED case

5. 9 Vector InitializeMake initialize the PTZ position value. With this function the camera keep the accuracy of the PTZ position value.

MAIN MENU

< NEAR / RIGHT → VECTOR INIT >

EXIT

MAIN MENU

< SEL → NEAR LEFT / RIGHT >

MOTION SETTING DOME SETTING CAMERA SETTING CLEAT DATA VECTOR INIT YES NO

5. 11 Other Quick Opercating Guide

5. 10 Compulsory Heater Operation

245 + Preset(3sec) : DAY MODE246 + Preset(3sec) : NIGHT MODE247 + Preset(3sec) : AUTO MODE248 + Preset(3sec) : WHITE LED ON (Only WHITE LED)249 + Preset(3sec) : WHITE LED OFF (Only WHITE LED)250 + Preset(3sec) : Camera Reset251 + Preset(3sec) : Focus the Lens

240 + Preset(3sec) : Heater operating for 5 min and turned OFF automatically.241 + Preset(3sec) : Turn OFF the compulsory Heater operation.255 + Preset(3sec) : Display Setting Value ( Ex : Address, Protocol, Camera, Video Mode And Temperture )

Inside of housing vapor condensed into the water on the dome cover because of temperature difference in the air between inside and outside of housing, user should compulsory operate heater.

EXIT

MOTION SETTING DOME SETTING CAMERA SETTING

CLEAT DATA LIGHT MODE

VECTOR INIT

Page 26: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

6. SPECIFICATIONS

50

RUGG

ED IR

PTZ

CAM

ERA

51

RUGG

ED IR

PTZ

CAM

ERA

6. 1 Mechanical Specifications

Model 26x NTSC / 26x PAL

Image Sensor

Effective Pixels

Lens

Digital Zoom

Angle Field of View

Scanning System

Synchronization

Frequency

Resolution

Min. Illumination

S/N (Y signal)

Video Output

Focus

IRIS Control

Camera Title

Day & Night

Gain Control

White Balance

Image Stabilizer

Electronic Shutter Speed

Control Output

Flip

Size

1/4" Super HAD CCD

NTSC: 680K / PAL: 800K Pixels

Optical 26x, Digital 12x

f=3.5 to 91mm(F1.6 to 3.8)

ON/OFF(Max. 12x)

H : 42˚(wide) to 1.6˚(tele)

Interlace

Internal

NTSC: 15.734 Khz(H), 59.94 Hz(V)

PAL: 15.625 Khz(H), 50.00 Hz(V)

470 TV Lines

0 Lux (IR ON)

50 dB

CVBS : 1.0Vp-p/75Ω

Auto / Manual / One-Push / Push auto / Auto manual

Auto / Manual

ON/OFF

ON/OFF (IR Cut Filter Removable)

Low, Middle, High, Manual, Off

1,800K ~ 10,500 K

ON/OFF

22 steps 1/1 to 1/10,000

2400, 4800, 9600, 19200, 38400 ,57600, 115200 bps

Mechanical Auto flip ON/OFF

138(Ø) X 212 (H)

6. 2 Camera Specifications

PanPan Preset SpeedTiltTilt Preset SpeedWeight

Construction

Ingress ProtectionColorOperating TempStorage TempHumidity

Preset Tour Pattern ScanDisplayAlarmFlipAddressData Communication ControlProtocolBaud rate

Power

ConsumptionFan & Heater

: 360° Continuous Pan, 0.1° to 100°/sec.: 110°/sec, 0.3° Accuracy: TOP 15°~270° , BOTTOM 345°~90° tilt angle , Proportional to zoom: 60°/sec, 0.3° Accuracy: Standard Model : Approx. 2.7kg / Packing 3.2kg: Additional LED Model : Approx. 3.5kg / Packing 4kg

: Die-casing Aluminum : All internal parts are corrosion protected epoxy powder coating: IP66 Outdoor Application: Ivory and Black: -20°C to 50°C (In continuous operation with Fan & Heater): -20°C to 50°C: 0% to 90%

: 63 points: 8 programmable: 2 patterns for Max. 90 second.: 4 programmable speed and diagonal scan: 2 Area Title: 2 alarm: Mechanical Auto Flip On/Off (Rotate: TOP 270˚ BOTTOM 90° at bottom of tilt): Up to 255 selectable ID ( setting with Dip-switches): RS-485/ RS-422: Multiple Protocol (WTX, PELCO-D V1, PELCO-P, PELCO-D V5): 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps selectable

: DC12V, 40W, 3.3A / AC24V, 50W, 2.1A Power adaptor not included: DC12V 0.9A(11W) / AC24V 0.6A(15W): DC12V IR: 1.9A(23W) AC24V IR: 0.9A(22W)

6. 1. 1 MECHANICAL

6. 1. 2 ENVIRONMENTAL

6. 1. 3 FUNCTIONS

6. 1. 4 ELECTRICAL

· 12VDC model is designed for vehicle application. Ground for both power and video is just one and therefore the power is not isolated and may damaged by surge input if it is installed in general circumstance not in Vehicle. · 24VAC is available for CCTV application

· 12VDC model is designed for vehicle application. Ground for both power and video is just one and therefore the power is not isolated and may damaged by surge input if it is installed in general circumstance not in Vehicle.

Page 27: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

52

RUGG

ED IR

PTZ

CAM

ERA

53

RUGG

ED IR

PTZ

CAM

ERA

7. 1 Standard Model

7. DIMENSIONS(mm)Image Sensor

Total Pixels

Scanning system

Scanning Frequency

Sync. System

Resolution

Min. illumination

Video Output

S/N Ratio

Lens type

Zoom Ratio

Focal Length

Aperture Ratio

Focus

Focus Distance

E. Zoom

Exposure

Gain Control

Shutter Speed

Digital Shutter Speed

Flickerless

Brightness

WDR

Day&Night

White Balance

Size

6. 3 LED Specifications

RUGG

ED IR

PTZ

CAM

ERA

Model 36x NTSC / 36x PAL

Infra Red LED Light Distance 120m manual focusing

12pcs of 18ø IR Lens LED

138

212

177

55

Ø90

Ø80

Ø60

145

Ø138

· 12VDC model is designed for vehicle application. Ground for both power and video is just one and therefore the power is not isolated and may damaged by surge input if it is installed in general circumstance not in Vehicle. · 24VAC is available for CCTV application

1/4" SONY Super HADⅡ(Double Scan) CCD

1028(H) × 508(V) , 1028(H) x 596(V)

2:1 Interlace

15.734KHz(H),59.94Hz(V) , 15.625KHz(H),50Hz(V)

Internal / External (V-Lock)

MAX 700 TV lines (COLOR) , 750 TV lines (BW)

Color : 0.5 lux , BW : 0.2 lux , Color DSS : 0.001 lux

BW DSS : 0.0004 lux

1.0 Vp-p (75 ohm, composite)

More than 50dB (AGC off)

36x Day & Night Zoom Lens

Optical 36x, Digital 32x Zoom

f = 3.4 mm ~ 122.4 mm

F1.6 (wide) ~ F4.5 (tele)

Auto / One Push / Manual

0.1 / 1.3 / 1.8 / 3.0 / 5.0 m

Off / Max 2x~32x

Auto / Shutter PRI / Iris PRI / Manual

Off / On (Auo Max 30dB)

1/60 ~ 1/100,000 sec , 1/50 ~ 1/100,000 sec

Off / Max 8x~512x

Off / On

1 ~15 steps

Off / On

Day / Night / Auto / Ext

ATW / One-Push / Indoor / Outdoor / Manual / Auto

138(Ø) X 212 (H)

Page 28: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

7. 2 Optional Bracket (Vihechle bracket)

54

RUGG

ED IR

PTZ

CAM

ERA

55

RUGG

ED IR

PTZ

CAM

ERA

8. FROUBLE SHOOTING

If you have trouble with operating camera, refer to the following table.If the guidelines do not enable you to solve the problem, contact an authorized technician.

Problem Solution

No video. Check that the power is connected to all pieces of equipment in the system.Check that the BNC connectors are inserted properly.Check if the iris of the lens is closed and adjust that.Check the camera’s fixed shutter menu and adjust that.

Check the voltage level of the camera.Check the power supply voltage.

Check if the camera and peripheral devices are properly connected.Verify the setups of ID, protocol, and baud rates.

Check the camera’s Brightness Level and adjust that.

Check the dome cover or camera lens and clean the dirt off.If Auto Focusing is having difficulty focusing on a particular subject,set Focus mode to Manual and adjust the focus by yourself.Reset the camera referring to 38 page.

Check if light mode is set correctly referring to 37 page.Check the Day & Night mode and converting Lux value referring to 36 page.

Check that Day & Night mode is set to AUTO mode referring to 36 page.Check the converting Lux value and adjust according tosurrounding’s illumination referring to 36 page.Check it the CDS sensor(there’s blue one beside of LED) is covered by something.

Check that the power is connected to all pieces of equipment in the system.Check that the BNC connectors are inserted properly.

Poor Video Quality.

Controller does not work.

Too dark or bright video.

Focus out video.

LED does not work.

Day or night modedoes not convertautomatically.

Pan, Tilt, Zoomdo not work.

130172

110

138

5t

9-M4 TAP THRU80

°

4-Ø9

70

20.8

28.8

40

R3

6.5

2-Ø4.4

175 20

200

226

70 143

4 - Ø8.9

Page 29: INSTALLATION / OPERATING MANUAL 26X / 36X ZOOM DAY & NIGHT RUGGED IR PTZ CAMERA · 2014-02-10 · RUGGED IR PTZ CAMERA 05 RUGGED IR PTZ CAMERA 3. FEATURES This stable and reliable

56

RUGG

ED IR

PTZ

CAM

ERA

57

RUGG

ED IR

PTZ

CAM

ERA