5/16 33734 Rev P 1 INSTALLATION & OPERATING INSTRUCTIONS IMPERIAL GAS LOGS Fi36S Fi36SL Fi36M Fi36ML Fi42S Fi42SL Fi42M Fi42ML FOR RESIDENTIAL USE WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency or the gas supplier. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. What to do if you smell gas Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas sup- plier. Heatilator, a brand of Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 55044 www.heatilator.com

Upload: truongque

Post on 09-Mar-2018

225 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

5/16 33734 Rev P 1

InstallatIon & operatIng InstructIonsImperIal gas logs

Fi36s Fi36sl Fi36m Fi36ml Fi42s Fi42sl Fi42m Fi42ml

For resIdentIal use

WarnIng!Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency or the gas supplier.

WarnIng: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

— Donotstoreorusegasolineorotherflammablevapors and liquids in the vicinity of this or any other appliance.

— Whattodoifyousmellgas • Donottrytolightanyappliance. • Donot touchanyelectricalswitch;donotuse

anyphoneinyourbuilding. • Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’sinstructions.

• Ifyoucannotreachyourgassupplier,callthefiredepartment.

— Installationandservicemustbeperformedbyaqualifiedinstaller,serviceagencyorthegassup-plier.

Heatilator, a brand of Hearth & Home Technologies7571 215th Street West, Lakeville, MN 55044

www.heatilator.com

Page 2: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

2 33734 Rev P 5/16

please retaIn thIs manual For Future reFerence

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

safety precautions1. Pleasereadtheseinstallationinstructionscompletelybeforebeginninginstallationprocedures.Failureto

followthemcouldcauseanappliancemalfunctionresultinginseriousinjuryand/orpropertydamage.2. Alwayscheckyourlocalbuildingcodespriortoinstallation.Theinstallationmustcomplywithalllocal,regional,

state and national codes and regulations.3. neVerleavechildrenunattendedwhenthereisafireburninginthefireplace.4. ThisGasLogSetapplianceisfactorybuilttoburnnaturalorpropanegas.Agasconversionkit(toconvert

fromnaturalgastopropane,orpropanetonaturalgas)isavailablefortheImperialSeries.5. Thefluedampermustbeopenatalltimeswhentheapplianceisinuse.6. Whileservicingthislogset,alwaysshutoffanyelectricityorgastotheappliance.Thiswillpreventpossible

electricalshockorburns.Also,makesurethefireplaceiscompletelycooledbeforeservicing.7. Solidfuelscannotbeburnedinafireplacewherethedecorativegasapplianceisinstalled.8. InordertoinstalltheImperialGasLogSetinthestateofMassachusetts,theCommonwealthofMassachusetts

requirestheexistingfireplacedamperberemoved.

table of contentsA. ListingsandCodeApprovals ...........................................................................................................................................3B. DescriptionoftheImperialGasLogSet..........................................................................................................................3C. ImportantInformation ......................................................................................................................................................5D. Step-by-StepInstallation .................................................................................................................................................6E. OperatingInstructionsforthe“M”Series ......................................................................................................................10F. OperatingInstructionsforthe“S”Series ....................................................................................................................... 11G. GlassDoors...................................................................................................................................................................12H. Cleaning ........................................................................................................................................................................12I. InspectingtheVentingSystem ......................................................................................................................................12J. ImportantSafeguards ....................................................................................................................................................13K. Servicing........................................................................................................................................................................13L. OwnerRegistration/Warranty ........................................................................................................................................13M. ReplacementParts ........................................................................................................................................................13N. Troubleshooting-“M”Series .........................................................................................................................................20O. Troubleshooting-“S”Series .........................................................................................................................................21P. AccessoryParts(For“M”SeriesOnly) ..........................................................................................................................22 Warranty ........................................................................................................................................................................23

WarnIng!this appliance is tested and listed for use only with the optional accessories listed in these instruc-tions. Use of optional accessories not specifically tested for this appliance could void the warranty and/or result in a safety hazard.

note: Anarrow() foundinthetextsignifieschangeincontent.

Page 3: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

5/16 33734 Rev P 3

ImperIal Gas loG set InstallatIon InstructIons

a. listings and code approvalsTheImperialSeriesGasLogSethasbeentestedandlistedintheU.S.inaccordancewithansI Z21.60-1996(GasLogSet).InCanadatheImperialSeriesGasLogSethasbeentestedandapprovedinaccordancewithcga 2.26-m96.IthasbeenlistedbyUnderwritersLaboratoriesInc.forinstallationandoperationintheUnitedStatesandCanadaasdescribedintheseInstallationandOperatingInstructions.AllcomponentsareUL,AGA,CGAorCSAsafetycertified.

Checkwithyourlocalbuildingcodeagencypriortoinstallingthisappliancetoensurecompliancewithlocalcodes,includ-ingtheneedforpermitsandfollow-upinspections.Intheabsenceoflocalcodes,complywiththenational Fuel gas code, ansI Z223.1-latest editionintheU.S.;inCanada,thecan/cga B149 Installation codes.Ifanyassistanceisrequiredduringinstallation,pleasecontactyourdealerformoreinformationorvisit:www.hpba.org/staysafe.

HEATILATOR®isaregisteredtrademarkofHearth&HomeTechnologiesInc.

WarnIng!this heatilator appliance and its components are designed to be installed and operated as a system. any alteration to or substitution for items in this system, unless allowed by these installation instruc-tions, will void the underwriters laboratories listing and may void the product warranty. It may also create a hazardous installation. read through these instructions thoroughly before starting your installation and follow them carefully throughout your project.

WarnIng!Do not use this appliance if any part has been under water. Immediately call a qualified service techni-cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

B. description of the Imperial gas log set

the heatIlator® Imperial gas log set consists of the following:

1. Burner/HearthAssembly2. GrateAssembly3. FourFiberLogs

optional components include:RC-BATT-HTLRemoteControl(M-Seriesonly)

Imperial series nomenclature

tools and building supplies nor-mally required for installation:

PliersPhillipsscrewdriverTapemeasure

CrescentwrenchesNon-corrosiveleak-checksolution

note: Theillustrationsanddiagramsusedthroughoutthese installation instructions are not drawn toscale.

Fi42ml logset order code numberFi ImperialSeriesLogSet

36 36”LogSet

42 42”LogSet

M IntermittentPilot

S SafetyPilotManualValve

NoSuffix NaturalGas

L PropaneGas

Page 4: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

4 33734 Rev P 5/16

Thesegaslogsetsareavailablewithdifferentvalvesystems.TheFi36S,Fi36SL,Fi42SandFi42SLsetsuseaseparateregulatorandvalvesystem,andtheFi36M,Fi36ML,Fi42MandFi42MLsetsuseacombinationcontrolwithanintermit-tentpilot.Bothvalvesystemsareavailableinnaturalorpropanegas.Onlythe“M”Seriescanbeusedwithanoptionalremotecontrol(RC-BATT-HTL).

Conversionkitstoconvertfromnaturalgastopropaneorfrompropanetonaturalgasareavailable.

• Theconversionkitsforall“M”serieslogsetsare:- dcKp toconvertfromnaturalgastopropane- dcKn toconvertfrompropanetonaturalgas.

• Theconversionkitsforall“S”serieslogsetsare:- cKmp toconvertfromnaturaltopropanegas- cKmn toconvertfrompropanetonaturalgas.

TheseHEATILATOR®gaslogsetsandcomponentshavebeentestedandwilloperatesafelywheninstalledinaccor-dancewiththisinstallationmanual.Thisdecorativeapplianceisahighlyengineeredsystem.UnlessyouuseHEATILA-TOR®componentswhichhavebeendesignedforthesystem,youmaycreateafirehazard.

GaspressureBTU/hr.Input

model no. Btu/hr. Input OrificeFi36M

60,000

.152

Fi36ML .093

Fi36S .169

Fi36SL .093

Fi42M

80,000

.182

Fi42ML .110

Fi42S .228

Fi42SL .110

gas pressureInletgassupplypressure(NG) 4.5(min)-7.0(max)in.w.c.

Optimalmanifoldpressure(NG) 3.5in.w.c.

Inletgassupplypressure(LP) 11.0(min)-14.0(max)in.w.c.

Optimummanifoldpressure(LP) 10in.w.c.

Page 5: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

5/16 33734 Rev P 5

ImperIal Gas loG set InstallatIon InstructIons

c. Important InformationInstaller:Pleaseleavetheseinstructionswiththeowner.owner: Please retain these instructions for future reference.Important: read these instructions carefully before making installation.• Thisappliancemustbeinstalledonlyinasolid-fuelburning(woodburning)fireplacewithaworkingflueand

constructedofnoncombustiblematerials.• Theapplianceareamustbekeptclearandfreefromcombustiblematerials,gasolineandotherflammable

vapors and liquids.• Afireplacescreenmustbeinplacewhenthelogsetisburningand,unlessotherprovisionsforcombustion

airareprovided,thescreenshallhaveanopening(s)forintroductionofcombustionair.• Installationandtheprovisionsforcombustionandventilationairmustconformwiththelatesteditionofthe

national Fuel gas code ansI Z223.1orinCanada,thecurrentcan/cga-B149.1 and B149.2.• Inletandoutlettapsareprovidedonthegascontrol(MSeries)foratestgaugeconnection.Replacetheplug

after the test.• Theapplianceanditsmanualshutoffvalvemustbedisconnectedfromthegassupplypipingsystemduring

anypressuretestingofthatsystemattestpressuresinexcessof1/2PSIG.• Theappliancemustbeisolatedfromthegassupplypipingsystembyclosingitsindividualmanualshutoff

valveduringanypressuretestingofthegassupplypipesystemattestpressureequaltoorlessthan1/2PSIG.

• TheminimumsizefireplaceinwhichthelogsetcanbeinstalledandtheminimumpermanentfreeopeningthatmustbeprovidedbyeitherthefireplacechimneyorchimneydampertoventthefluegasesmustbeinaccordancewiththetablesinFigure1.

• Anychimneydampermustbefixedsothattheminimumpermanentventopeningwillbemaintainedatalltimes(byscrew,boltatdamperedge,orholeindamper.)

• Solidfuelshallnotbeburnedinafireplacewhereadecorativegasapplianceisinstalled.

1. high altitude Installation ForU.S.installation,appliancesaretestedandapprovedforelevationsfrom0-2000feet.WheninstallingthisImperialGasLogSetatanelevationabove2000feet,NationalFuelGasCodesrequireadecreaseoftheinputratingbychangingtheexistingburnerorificetoasmallersize.Inputshouldbereduced4%foreach1000feetabovesealevel.Checkwiththelocalgasutilityforproperorificesizeidentification.ThecurrentorificeisavailablefromyourHeatilatordistributor.

ForCanada,appliancesarecertifiedforelevationsfrom0-4500feet.WheninstallingthisImperialGasLogSetatanelevationbetween0-4500feetinCanada,theinputratingdoesnotneedtobereduced.Wheninstallingthislogsetatanelevationabove4500feetinCanada,checkwithlocalauthorities.

2. minimum dimensions

Figure 1

minimum Firebox dimensions minimum permanent Free opening

SetSize Depth Height FrontOpening ChimneyHt.(ft) 36 in. 42 in.

36 in. 13 in. 16 in. 30 in. 10 ft 40 sq in. 40 sq in.

42 in. 13 in. 16 in. 34 in.

Page 6: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

6 33734 Rev P 5/16

d. step-by-step Installation

Ifthedamperstopdoesn’tfityourapplication,useaper-manentmeansthatwillkeepthedamperopenatleasttotheminimumventopening.SeeFigure1.

3. position the log set in the FireplaceTheburnerassemblyshouldbelocatedasfarbackaspossibleandcenteredlefttorightinthecombustioncham-beroftheventedfireplace.

4. connect the gas lineTheapplianceisprovidedwithastainlesssteelflexibleconnectorandalisted(andCommonwealthofMassachu-settsapproved)T-handlemanualshutoffvalve.

a. Remove the four screws that secure theburnerassemblytothetoppan.SeeFigure3.

b. Removethefourscrewsthatsecurethetoppantothebaseoftheappliance.SeeFigure4.

1. unpack the log setCarefullyremoveallpartsfromtheshippingcontainer.Yoursetincludesfourfiberlogs,aburnerassembly,thegrateassembly,fireembers,lavarock,damperstop,and10”flexconnector.

2. Install the damper stopToinstallthedamperstop:OpenthedampertothefullyopenpositionandsecureitopenwiththestopasshowninFigure2.

c. Settheburnerassemblyandtoppanaside.d. ThegaslineconnectionfortheImperialSeriesGas

LogSetmaybeplumbedfromeithertherightorleft side of the appliance.

e. The1/2”ironpipeincominggaslineshouldbepipedintothevalvecompartmentfromeithertherightorleftsideandconnectedtothebrassflareconnectorandthe10”stainlesssteelflexline(supplied).SeeFigure5.

optional: Sealaround thegas line toprevent coldairleakage.

note: Thisappliancemustbe installedwithamanualshutoffvalve(notsupplied)locatednomorethansixfeetfromtheappliance.

Figure 2 - damper operation

Figure 3 - Burner assembly

Figure 4 - top pan

Figure 5 - gas line connection

note: Havethegassupplylineinstalledinaccordancewithbuildingcodesbyaqualifiedinstallerapprovedand/orlicensedasrequiredbythelocality.IntheCommonwealthofMassachusetts,installationmustbeperformedbyalicensedplumberorgasfitter.

Page 7: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

5/16 33734 Rev P 7

ImperIal Gas loG set InstallatIon InstructIons

f. Bleed the gaslinetoextractanyairthatmayhavebeen trapped inside the pipe.All connectionsmustbe tightenedandchecked for leakswithacommerciallyavailable,non-corrosiveleakchecksolution.Besuretorinseoffthesolutionwhendoneleaktesting.DONOTUSEANOPENFLAME.Turnoffthegasaftertheleaktest.

g. Reassemble the top panwith the four screwsremovedearlier,andtheburnerassemblywiththefourscrewsremovedearlier.

5. grate assemblyThegrateassemblyshouldbepositionedontopofthetoppanandtheburnerassemblies,centeredfromlefttorightandpulledforwardasfaraspossible.SeeFigure6.

note: Be sure when reassembling the burnerassemblythattheburnerneckisproperlypositionedontheorifice.

6. place the rock Wool, Fire glow, lava rock and Vermiculite

a. RockWool Placeapproximately1/2”diameterpiecesofrock

woolonthetopoftheburnercoveringthefront2/3oftheburner.Donotcovertherearrowofburnerports.Therockwoolshouldalsobeplacedtothesidesoftheburneronthetoppanandunderthefrontbarofthegrateassemblytohidetheburner.SeeFigure7.

b. FireGlow(Fire98) A flame colorantmaterial that also adds to the

realismof thegasapplianceflame.Afterplacingtherockwool,sprinklesomeoftheFireGlowonthetopoftheburnerassemblyandtherockwool.

Figure 6 - placing the grate assembly

c. lava rockPlaceonthehearthrefractoryofthefireplace,allaroundthelogset.SeeFigure8.

Figure 7 - rock Wool placement

Figure 8 - lava rock

d. Vermiculite Whenplacingthevermiculite,sprinkleitevenlyover

theareacoveredbythelavarock.e. Itisnotnecessarytousetheentirebagoftherock

wool,theFireGlow,thelavarockorthevermiculite.Savetheremainingportionsforlateruse.

Page 8: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

8 33734 Rev P 5/16

7. place the logsa. RearLog Therearlogissuppliedwithlocatingslotsinthe

baseofthelog.Locatetherearlogoverthelocatingtabsattherearofthetoppan.SeeFigure9.

Figure 9 - rear log placement

b. FrontLog Thefrontlogissuppliedwithnotchesinthebase

ofthelogto locatethelogonthegrate.Lineupthenotchesinthelogwiththegratebarsandpullthelogforwarduntilitcomesintocontactwiththeuprightportionofthegratebars.SeeFigure10.

c. TopRightLog Thetoprightlogissuppliedwithlocatingslotsin

thebaseof the log.Locate the logover the twolocating pins found in the rear log and the front log. SeeFigure11.

Figure 10 - placing the Front log

Figure 11 - top right log

Figure 12 - top left log

d. TopLeftLog Thetopleftlogissuppliedwithalocatingtabthat

fits intoanotchon the topof the front log.SeeFigure12.

Page 9: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

5/16 33734 Rev P 9

ImperIal Gas loG set InstallatIon InstructIons

8. Intermittent pilot Ignitiona. ApplianceRequirements:Thisappliancedoesnotrequire110VACsupplyforoperation.

1) A wiringdiagramisshowninFigure13.Abatterypackissuppliedwiththeappliance.ThisappliancerequirestheuseoftwoD-cellbatteries(notsuppliedwiththeappliance)foroperation.

2) Intheeventofapoweroutage,theappliancewillcontinuetooperateifbatteriesareinstalledinthebatterypack.

Figure 13 - “m” series Intermittent pilot Wiring diagram

b. BatteryReplacement1) AccessCover-Removetheaccesscoverbylocatingthetwohandtabsoneithersideoftheaccesscover.

Slidetheaccesscovertotherightapproximately1”todisengageitfromthebase.SeeFigure14.2) BatteryPack-Locatethebatterypackandslideitforwardoutofthebase.SeeFigure15.Replacebatteries

andreinstallthebatterypackintothebase.Thebatterypackisheldinplacebyamagnetlocatedonthebasepan.

Figure 14 - access cover removal Figure 15 - Battery replacement

on/oFF switch

Page 10: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

10 33734 Rev P 5/16

e. operating Instructions for the “m” series

LightingInstructions,“M”Series

FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance has an intermittent pilot. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle to the floor.

WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use

any phone in your building. • Immediately call your gas supplier?from a

neighbor's phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire department.

C. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Due to high surface termperatures, keep children, clothing and furniture away.Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.

LIGHTING INSTRUCTIONS1. STOP! Read the safety instruction label.2. Turn wall switch to the "OFF" position.

3. Wait five minutes to clear out any gas. If you smell gas, STOP! Follow "B" on the safety information label. If you don't smell gas, go to next step.

4. Locate pilot assembly inside unit.

6. If appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE" and call your service technician or gas supplier.

TO TURN OFF GAS APPLIANCE1. Turn on/off switch to "OFF".

GAS CONTROL

KNOB

FLAME SENSOR

IGNITOR

5. To light pilot and main burner, turn wall switch to "ON". Do not light by hand.

34006

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

PILOT BURNER

Page 11: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

5/16 33734 Rev P 11

ImperIal Gas loG set InstallatIon InstructIons

F. operating Instructions for the “s” series

FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle to the floor.

WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use

any phone in your building. • Immediately call your gas supplier?from a

neighbor's phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire department.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service techni-cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Due to high surface termperatures, keep children, clothing and furniture away.Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.

LIGHTING INSTRUCTIONS1. STOP! Read the safety instruction label. 5. Turn knob on control counterclockwise to "PILOT".

3. Wait five minutes to clear out any gas. If you smell gas, STOP! Follow "B" on the safety information label. If you don't smell gas, go to next step.

4. Find pilot--follow metal tube from gas control. The pilot is behind the burner pan.

6. Push in the knob all the way and hold in. Immediately light the pilot with the use of a paper match and lighter rod. Continue to hold the control knob in for about one minute after the pilot is lit. Release button and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 3 through 7.

If button does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

7. Turn gas control knob counterclockwise to "ON". Knob can be turned to "ON" only if the control knob is popped out.

TO TURN OFF GAS APPLIANCE1. Turn gas control clockwise to "OFF. Do not force.

2. Turn gas control knob clockwise to "OFF".

PILOT BURNER

THERMOCOUPLE

34008

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

LightingInstructionsforthe“S”Series

Page 12: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

12 33734 Rev P 5/16

g. glass doorsIfyourfireplaceisequippedwithaglassdoor,theglassdoorsshouldbeinthefullopenpositionwhentheapplianceisoperating.Operatingthefireplacewiththeglassdoorsclosedwillblocktheradiantheatoutputofthefireplaceandmaycauseincompletecombustionofthenaturalorpropanegasfuel.

Important! Alwaysensurethatthewirefireplacescreenisclosedwhenthefireplaceisoperating.

Yourgaslogsrequirelittlecare.Keeptheburnerassembly,logsandburnerareasurroundingthelogscleanbyvacuum-ingorbrushingwithadrypaintbrushatleasttwiceayear.

• Alwaysturnoffthegastothepilotbeforecleaning.Forrelighting,refertolightinginstructionslocatedonpages 10 and 11.

• Alwayskeeptheapplianceclearandfreefromcombustiblematerials,gasoline,andotherflammablevaporsand liquids.

• Neverobstructtheflowofcombustionandventilationair.Keepthefrontoftheapplianceclearofallobstaclesandmaterials.

• Leaveclearanceofatleast36”fromthefrontofthefireplace.• Theairshuttershouldnotbeblocked.

cautIon:the logs can get very hot. handle only when they are cool.

cautIon:after burning, the log becomes fragile, so take care in handling.

Thefireplaceventingsystemisdesignedandconstructedtodevelopapositiveflowadequatetoremovefluegasestotheoutsideatmosphere.Seeventedfireplaceinstallationinstructions.

1. a spillage test must be made before the installed appliance is left with the consumer.a. Closealldoorsandwindowsinthehome.b. Lightthelogset.c. Afterthreeminutes,testwithasmokematch,smokecandle,stickincense,orcigarette1”belowthetop

oftheopening(lintel)movingacrossthefullwidth.SeeFigure16.Ifspillage(smokedrawnintotheroom)occurs,itwillmostlikelybenearthetop,outsidecorners.

Figure 16 - checking for spillage

h. cleaning

I. Inspecting the Venting system

Page 13: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

5/16 33734 Rev P 13

ImperIal Gas loG set InstallatIon InstructIons

2. possible curesa. Thedamperneedstobeopenedfurther.b. Thefireplaceopeningneedstobereducedbyaddingadroppanelacrossthetopunderthelintel.c. Theairsupplyfromoutdoorsneedstobeincreased.Opentheoutsideairkitifthefireplaceissoequipped,

orcrackopenadoororwindow.d. Ifnecessary,seekexpertadvice.Donotoperatethisappliance.3. cleaningPeriodicexaminationandcleaningoftheventingsystemofthesolid-fuelburningfireplaceshouldbedonebeforeinitialuseandatleastannuallybyaqualifiedagency.

1. other Fuelsa. Althoughyourgaslogsetisveryrealisticinappearance,itisnotarealwoodburningfireandmustnotbe

usedforburninganyfuelotherthannaturalorpropanegas.b. Toavoidirreparabledamagetotheapplianceand/orpersonalinjury,wood,matches,paper,garbageorany

othermaterialmustnotbeplacedorthrownontopofthelogs.2. Fireplace safetya. Toavoidpersonalinjury,donottouchhotsurfaceswhentheapplianceisoperating.b. Alwaysensurethatthefireplacescreenisclosedwhentheapplianceisoperating.c. Closesupervisionisnecessarywhentheapplianceisbeingusednearchildren.

• Repairandreplacementworkshouldbedonebyaqualifiedservicetechnician.• Always shut off the gas supply andmake sure the appliance is cool before beginning any service

operation.• Alwayscheckforgasleaksafterservicing.• Alwayscheckforproperventing.

m. replacement partsPartslistswithexplodedviewsfollow.Alwaysincludecorrectname,partnumberandmodelnumberoftheappliancewhenorderingreplacementparts.Contactyourlocaldealertoorderparts.

J. Important safeguards

K. servicing

l. owner registration/WarrantyPleasecompleteandreturnyourownerregistrationcardtoensureproperwarrantycoverage.Ifyouwishtocommunicatewiththefactory,writetoHeatilatorTechnicalServicesDept.,Hearth&HomeTechnologiesInc.,1915W.SaundersStreet,Mt.Pleasant,Iowa52641

Page 14: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

14 33734 Rev P 5/16

Service Parts FI36M, FI36MLBeginning Manufacturing Date: N/A Ending Manufacturing Date: Active

Part number list on following page.

Log Set Assembly

Imperial 36” Gas Log Set

13

24

5

6

7

8

91110

12 13

1415

16

17

18

04/16

Page 15: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

15 33734 Rev P 5/16

Service Parts FI36M, FI36MLBeginning Manufacturing Date: N/A Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.

Stocked at Depot

ITEM DESCRIPTION COMMENTS PART NUMBER1 Back Log

Pre 5/15/16 must order all logs

SRV322332 Front Log SRV322343 Top Right Log SRV337324 Top Left Log SRV337335 Grate Assembly 337436 Burner Assembly 33725 Y7 Control Module 593-595 Y8 Brass Connector Pkg of 5 303-315/5 Y

9Valve NG 593-500 YValve LP 593-501 Y

10 Brass Male Connector 1342511 Gas Tube 33729

12Ori ce NG (.152) 32229 YOri ce LP (.093) 16752 Y

13 Bulkhead 13405A

14Pilot Assembly NG 4021-730 YPilot Assembly LP 4021-731 Y

15 Pilot Bracket 3337516 Battery Pack 593-594A Y17 ON/OFF Rocker Switch 060-51118 Access Cover 32238

Damper Stop Assembly 14354 YFlex Gas Line 17245B YDexen Wire Harness 593-590A YWool, Rock, Vermiculite 34010

Lava Rock (2lb. Bag) 4021-296Mineral Wool 14333BVermiculite 28746

"Z" Bracket 32228Wire Harness Qty 2 req 33995Conversion Kit NG DCKN YConversion Kit LP DCKP Y

Pilot Ori ce NG, .021 446-505 YPilot Ori ce LP, .011 446-517 YRegulator NG NGK-DXF YRegulator LP LPK-DXF Y

Installation Manual 33734

Page 16: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

16 33734 Rev P 5/16

service parts FI36s, FI36slBeginning manufacturing date: nov 2000

ending manufacturing date: nov 2006

IMPORTANT:THISISDATEDINFORMATION.Partsmustbeorderedfromadealerordistributor. hearth and home technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.

stockedat depot

Item descrIptIon comments part numBer

1 BackLog SRV32233

2 FrontLog SRV32234

3 TopRightLog SRV33732

4 TopLeftLog SRV33733

5 GrateAssembly 33743

6 BurnerAssembly 33725 Y

7PilotAssemblyNG 33993 Y

PilotAssemblyLP 33994 Y

8 PilotBracket no longer available 33735

9 GasTube no longer available 33989

10 BrassMaleConnector 13425

11 Valve 33992 Y

12 Pipe Nipple 4021-041

13 Regulator 34028

14OrificeNG(.169) 18742

OrificeLP(.093) 16752 Y

15 BrassBulkhead 13405A Y

16 BrassConnector-90degree-Flex 4021-045

BrassConnector Pkgof5 303-315/5 Y

DamperStopAssembly 14354 Y

10in.Flexline 302-320A Y

Wool, rock, Vermiculite 34010

LavaRock(2lb.Bag) 4021-296

MineralWool 14333B

Vermiculite 28746

ConversionKitNG no longer available CKMN

ConversionKitLP no longer available CKMP

2/15

log set assembly

Imperial 36” gas log set

5

6

7

8

9

1011 12 13

14

1516

13

24

Page 17: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

17 33734 Rev P 5/16

Service PartsBeginning Manufacturing Date: N/A Ending Manufacturing Date: Active

FI42M, FI42ML

Part number list on following page.

Log Set Assembly

Imperial 42” Gas Log set

13

24

5

6

7

8

91110

12 13

1415

16

17

18

04/16

Page 18: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

5/16 33734 Rev P 18

Service PartsBeginning Manufacturing Date: N/A Ending Manufacturing Date: Active

FI42M, FI42ML

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.

Stocked at Depot

ITEM DESCRIPTION COMMENTS PART NUMBER1 Back Log

Pre 5/15/16 must order all logs

SRV322332 Front Log SRV322343 Top Right Log SRV337324 Top Left Log SRV337335 Grate Assembly 337436 Burner Assembly 33725 Y7 Control Module 593-595 Y8 Brass Connector Pkg of 5 303-315/5 Y

9Valve NG 593-500 YValve LP 593-501 Y

10 Brass Male Connector 1342511 Gas Tube 33729

12Ori ce NG (.182) 32230Ori ce LP (.110) 17235 Y

13 Bulkhead 13405A

14Pilot Assembly NG 4021-730 YPilot Assembly LP 4021-731 Y

15 Pilot Bracket 3337516 Battery Pack 593-594A Y17 ON/OFF Rocker Switch 060-511 Y18 Access Cover 32238

Damper Stop Assembly 14354 YFlex Gas Line 17245B YDexen Wire Harness 593-590A YWool, Rock, Vermiculite 34010

Lava Rock (2lb. Bag) 4021-296Mineral Wool 14333BVermiculite 28746

"Z" Bracket 32228Wire Harness Qty 2 req 33995Conversion Kit NG DCKN YConversion Kit LP DCKP Y

Pilot Ori ce NG, .021 446-505 YPilot Ori ce LP, .011 446-517 YRegulator NG NGK-DXF YRegulator LP LPK-DXF Y

Installation Manual 33734

Page 19: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

19 33734 Rev P 5/16

Service PartsBeginning Manufacturing Date: Nov 2000

Ending Manufacturing Date: Nov 2006

FI42S, FI42SL

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.

Stocked at Depot

ITEM DESCRIPTION COMMENTS PART NUMBER

1 Back Log SRV32233

2 Front Log SRV32234

3 Top Right Log SRV33732

4 Top Left Log SRV33733

5 Grate Assembly 33743

6 Burner Assembly 33725 Y

7Pilot Assembly NG 33993 Y

Pilot Assembly LP 33994 Y

8 Pilot Bracket No longer available 33735

9 Gas Tube No longer available 33989

10 Brass Male Connector 13425

11 Valve No longer available 33992 Y

12 Pipe Nipple 4021-041

13 Regulator 34028

14Ori ce NG (.228) 33736

Ori ce LP (.110) 17235 Y

15 Brass Bulkhead 13405A Y

16 Brass Connector - 90 degree - Flex 4021-045

Brass Connector Pkg of 5 303-315/5 Y

Damper Stop Assembly 14354 Y

10 in. Flexline 302-320A Y

Wool, Rock, Vermiculite 34010

Lava Rock (2lb. Bag) 4021-296

Mineral Wool 14333B

Vermiculite 28746

Conversion Kit NG No longer available CKMN

Conversion Kit LP No longer available CKMP

3/16

Log Set Assembly

Imperial 42”Gas Log set

5

6

7

8

9

1011 12 13

14

1516

13

24

Page 20: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

20 33734 Rev P 5/16

Withproperinstallationandmaintenance,yournewdecorativegasapplianceshouldprovideyearsoftrouble-freeservice.Ifyoudoexperienceaproblem,refertothetroubleshootingguidebelow.Thisguidewillassistyouoraqualifiedservicetechnicianinthediagnosisofproblemsandthecorrectiveactiontobetaken.

n. troubleshooting - “m” series

symptoms possible causes corrective action1 Pilotsparks,butwillnotlight

afterrepeatedattempts. a. Maingasshutoffvalveclosed. Makesurethattheshutoffvalvelocatedonthe

incominggaslineisopen.

b. Air in the gas line. Bleedairoutofthegasline.Retestforgasleaksafterbleeding.

c. Pilotorificeisplugged,notallowinggastoflow.

Thisrepairrequirestoolsandsomedegreeofexperience.Callaqualifiedservicetechnician.

d. Misalignedelectrode. Checksparkgap;sparkshouldbeextendingapproximately1/8”tothepilothood.Adjustgaptogiveproperspark.Removehandsfromelectrodebeforeattemptingtospark.

e. No gas supply to the appliance. Checkplumbingtoensuretheappliancehasbeenhookeduptothegassupplyline. Thepropanetankisempty.

f. Groundwireloose. Checkthattheblackgroundwirefromtheignitioncontrolboxissecurelyattachedtotheground.

g. Weakbatteries. Replacewithtwonew“D”sizedbatteries.

2 Pilotlights,butwillnotstaylit. a. Weakpilotflame. Pilotflamemustengulftheflamesensor.Cleanand/oradjustpilotformaximumflameimpingementonflamesensor.

b. Loosewireconnection Checkforloosewiresfromthepilottotheignitioncontrolbox.

c. Faultyflamesensor. Checkthewireconnectionintotheignitioncontrolbox.Iftheconnectioniscorrect,replacesensor.

3 Pilotdoesnotsparkatall. a. Loosewireconnection. CheckforloosewiresfromOn/Offswitchtoignitioncontrolandremotecontrol.

b. Remotecontrol. Makesuretheswitchlocatedonthefrontoftheremotecontrolissettothe“Remote”setting.

c. Weakbatteries. Replacewithtwonew“D”sizedbatteries.

Page 21: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

5/16 33734 Rev P 21

ImperIal Gas loG set InstallatIon InstructIons

o. trouBleshootIng - “s” serIessymptoms possible causes corrective action

1 Matchwillnotlightpilot. a. Maingasshutoffvalveclosed. Makesurethattheshutoffvalvelocatedontheincominggaslineisopen.

b. Air in the gas line. Lightamatch.Turnvalveknobto“PILOT”positionanddepress.Keepmatchnearpilotburneruntilitlights.

c. Valveknobisin“OFF”position Turnvalveknobto“PILOT”positionanddepress.Keepmatchnearpilotburneruntilitlights.

d. Pilotorificeisplugged,notallowinggastoflow

Thisrepairrequirestoolsandsomedegreeofexperience.Callaqualifiedservicetechnician.

e. No gas supply to the appliance. Checktheplumbingtoensuretheappliancehasbeenhookeduptothegassupplyline.

2 Pilotlights,butwillnotstaylitaftercarefullyfollowinglightinginstructions.

a. Thermocoupletootightortooloose.

Thermocouplemustbeattachedtothevalvefinger-tight,plusa1/8turnwithawrench.

b. Weakpilotflame. Pilotflamemustengulfthethermocouple.Cleanand/oradjustpilotformaximumflameimpingementonthethermocouple.

c. Defectivethermocouple. Checkthethermocouplewithamillivoltmeterasfollows:Disconnectthethermocouplefromthevalveandconnecttheredleadofthemetertothesilverendofthethermocouple.Nowconnecttheblackleadofthemetertothecoppertubingofthethermocouple.Lightthepilotandkeeptheknobdepressedwhiletakingreadings.Themeterreadingsshouldbegreaterthan14mV.Ifnot,replacethermocouple.

3 Pilot“ON”.Nogastomainburner,valveknob“ON”.

a. Ablockageispreventinggasflow.

Inspecttheburnerorificeforobstruction.Callaqualifiedservicetechnician.

b. Defective valve. Replacegasvalve.Callaqualifiedservicetechnician.

Page 22: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

22 33734 Rev P 5/16

p. accessory parts (For “m” series only)Thefollowingaccessorypartscanbeobtainedfromyourdealer.Thewirelessremotecontrolswitchissuppliedwithinstallationinstructionspackagedwiththem.Shouldyouneedadditionalinformationpleasecontactyourdealerformoreinformationorvisit:www.hpba.org/staysafe.

remote control

rc-Batt-htl

Page 23: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

5/16 33734 Rev P 23

4021-645C 12-29-10 Page 1 of 2

Hearth & Home Technologies Inc.LIMITED LIFETIME WARRANTY

Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.

WARRANTY COVERAGE:HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo-nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below.

WARRANTY PERIOD:Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for parts and labor for covered components is produced in the following table.The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.

See conditions, exclusions, and limitations on next page.

Parts Labor Gas Wood Pellet EPAWood Coal Electric Venting

X X X X X X X

All parts and material except as covered by Conditions,

Exclusions, and Limitations listed

X X X Igniters, electronic components, and glass

X X X X X Factory-installed blowersX Molded refractory panels

X Firepots and burnpots

5 years 1 year X X Castings and baffles

7 years 3 years X X X Manifold tubes, HHT chimney and termination

10 years 1 year X Burners, logs and refractory

Limited Lifetime 3 years X X X X X Firebox and heat exchanger

X X X X X X X All replacement partsbeyond warranty period

Warranty Period HHT Manufactured Appliances and Venting

1 Year

Components Covered

3 years

2 years

90 Days

Page 24: InstallatIon & operatIng InstructIons ImperIal gas · PDF fileInstallatIon & operatIng InstructIons ImperIal gas logs Fi36s Fi36sl Fi36m Fi36ml ... RC-BATT-HTL Remote Control (M-Series

24 33734 Rev P 5/16

4021-645C 12-29-10 Page 2 of 2

WARRANTY CONDITIONS:• This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of

HHT authorized dealers is available on the HHT branded websites.• This warranty is only valid while the HHT appliance remains at the site of original installation.• Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact

the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product.

• Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this warranty.

This warranty is void if:• The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging

chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling, cracking and discoloration of steel or enamel finishes.

• The appliance is subjected to prolonged periods of dampness or condensation.• There is any damage to the appliance or other components due to water or weather damage which is the result of, but

not limited to, improper chimney or venting installation.

LIMITATIONS OF LIABILITY:• The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or

implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you. This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE.

WARRANTY EXCLUSIONS:This warranty does not cover the following:• Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and

exterior surface finishes may occur. This is not a flaw and is not covered under warranty.• Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items,

or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.• Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts

include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, light bulbs, batteries and the discolor-ation of glass.

• Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and com-plaints related to this noise are not covered by this warranty.

• Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper opera-tion, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/ incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7) installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing; and/or (9) interruptions or fluctuations of electrical power supply to the appliance.

• Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance.• Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed.• HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Informa-

tion is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consider-ation must be given to appliance location and configuration, environmental conditions, insulation and air tightness of the structure.