Installation manual

P L U SP L U S & P R O

2

Safety warnings

3

Manual for Maxem Plus and Pro Energy Manager.

Publication Date: May 15, 2017

Safety Information

Liability

• Onlytobeinstalledbyacertifiedelectrician.

• Completely follow the instructions given in this manual.

• Use this device only for the purpose it is designed for, as described in this

manual.

• Maxem works only after online activation.

• Failure to follow the above warnings can lead to an incorrect Maxem installation.

This can lead to over current of the grid connection, damage to installations and

chargingstations,electricshocksorfire.

All information in this document is the copyright and intellectual property of Cohere Energy

SolutionsB.V.Materialinthisdocumentmaynotbemodified,reproducedorcopied,inpart

or in whole, without the explicit written consent of Cohere Energy Solutions B.V. Additional

information is available upon request.

Maxem is a registered trademark of Cohere Energy Solutions B.V.

S M A R T C H A R G I N G C O N T R O L L E RC H A R G E S M A R T E R

Product symbols statements

©2017 COHERE ENERGY SOLUTIONS B.V.

Tip Warning

Symbols in this document

Questions or improvements

If you see any errors or defects, if you have ideas about how to improve this manual or the Maxem system, please send an email with your feedback to [email protected].

Cohere is not responsible for the installation of Maxem and for any damage arising from not

following the installation manual correctly. Nor for damage resulting from typographical

errors or misinterpretations of text or images.

Install and use this product only after careful reading of the manual.

This product is double insulated.

Indoor use only.

Product contains electronics. Do not throw it in the household waste.

This product is designed for overvoltage category III.

This product meets all the requirements set by the EU for

product safety.

Index

What is Maxem? 5

Productspecifications 6

Installation requirements 8

Fuse settings of charging stations 10

Installation Steps

01 - Mounting on the wall 11

02 - Installing kWh-meter for main grid connection 12

Option 2.1 - Installing kWh-meter Maxem Plus (<80A) 12

Option 2.2 - Installing kWh-meter Maxem Pro (>80A) 14

03 - Installing kWh-meter for solar panels 17

04 - Connecting charging stations

Option 4.1 - Connecting KEBA charging stations 18

Option 4.2 - Connecting ICU charging stations 20

Option 4.3 - Connecting EV-Box charging stations 21

05 - Connecting Maxem 23

06-Configurationandcommissioning 24

Appendix 1 - Troubleshooting 27

Appendix2-Configuring65AkWh-meter 29

Appendix 3 - Crimping RJ connectors 30

EU Declaration of Conformity 31

What is Maxem?

From the main grid panel, Maxem measures the energy use in the house and the energy

generation of solar panels. Based on this information, it manages the power between the

building and multiple charging stations. This way there is no risk of over current on the grid

connection and it is easier to utilize the produced solar power. Also more charging stations

can be installed than normal.

4 5

Safely install more charging stations athigher power without the risk of overloading the grid connection. Maxem controls the charge capacity of each charging station per second.

More charging stations

Install up to 250 charging stations to let the charge park grow over time with the increase electric vehicles. Maxem is easily expanded.

Flexible expansion

Maxem optimizes energy flows in the building.

Maxem

Grid

Maxem measures the power generation of solar panels. Maxem is able to control the charging stations based on this generation. This way you make 100% use of your own renewable energy!

Solar panels

Maxem optimizes the power consumption of the main grid connection to prevent over current. This way you can save significantly on an expensive grid upgrade.

01 - Voorbereidingen vooraf

Content of the box

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

Optional Solar kWh-meter

1x Maxem including mounting plate

1x RS485 cable (1m)

1x Power cable (1m)

4x Screws 3x20

2x RJ10 4P4C connector

Productspecifications

Specifications

SETOK

1 2 3

1xSolarkWh-meter(<65)

P1 port

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

Input/output ports and LED indicators

Current transformers solar panels

Free power measurement port

Current transformers grid connection

RS485 port 1

RS485 port 2

RS2RS1P1 CT3CT2CT1

6 7

SETOK

1 2 3

1x Direct kWh-meter 3-phase 80A

Optional Ethernet switch

1x Ethernet switch with power supply

1x Network cable

1x RS485 splitter

1x Network cable (1m)

1x RS485 cable(1m)

kWh-meter for Maxem Plus

1x Indirect kWh-meter 3-phase

kWh-meter for Maxem Pro

3x Split-core current transformer250A, 500A of 1000A

SETOK

1 2 3

O.OFF O.OFF O.OFF O.OFF

SETOK

1 2 3

1x 10A Circuit breaker

Dimensions 184mm(L)x167mm(W)x55mm(H)

Weight 700g

Working temperature 10°C to 35°C

Storage temperature 0°Cto60°C

Maximal humidity 80%

Protection class II (double insulated)

Seal IP20

Operational level 0 to 2,000 m

EMC EN61326-1(2013),EN61000-3-2,61000-3-3

Safety EN61010-1(2010),EN61010-2-30(2010)

Immunity EN61326-1(2013)

Overvoltage category 300V/CAT III

Input power 110-240V.50/60Hz.Maximum2,75W

Ethernet port to charging stations

Ethernet port to Internet Router

Power supply

Necessary tools

• A correct circuit breaker or earth leakage circuit breaker with proper safety fuse value.

See p. 10 to determine the fuse settings.

• Schuko sockets for 230V power supply Maxem (if not already available).

• UTP(CAT5orCAT6)datacableforconnectingchargingstationstoMaxem.

• RJ45 (8P8C) connectors for UTP cable.

• Cable end sleeves for UTP cores (only for Tesla Wall Connector or EV-Box).

Necessary materials• Free space for Maxem with connected wiring at the bottom.

• Free Schuko 230V socket to power Maxem or free space to place a new one.

• Free Ethernet port for Internet connected modem or router.

• An UTP cable must be pulled (or already be available) from Maxem to the charging

station.

• Maxem Plus:

• Free space in grid panel for kWh-meter: 7 modules / 123 mm on DIN-rail.

• Maxem Pro:

• Free space in grid panel for kWh-

meter:4modules/76mmon

DIN-rail.

• Free space in grid panel for 10A

circuitbreaker:4modules/76

mm on DIN-rail.

• For Ethernet connected charging

stations:

• Free space for ethernet switch.

• Free space for wall socket for

power supply of ethernet

switch.

Environmental Requirements

01 - Voorbereidingen voorafInstallation requirements

Wired Internet connection

With Maxem Plus/Pro compatible charging stations

ICU EVe mini*KEBA P20/P30 C-series ICU EVe*

*ICU charging stations have to be ordered ‘Maxem Ready’.

**Compatibility of Maxem with multiple EV-Boxes is still in development. Check the Maxem website for the

latest overview of compatible charging stations.

98

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

184mm

55,50mm

20mm

70mm

20mm20mm

Maxem

167mm

EV-Box Home** EV-Box Business**(G3 controller)(G3 controller)

Maxem must be connected to a wired Internet connection. The following is needed:

• Modem or router connected to Internet.

• A DHCP connection from the network to Maxem.

• Maxem should be able to do DNS requests.

• Maxem may also be placed in a DMZ (demilitarized zone) on a separate VLAN.

• Outbounddatatrafficmustbepossibleoverports80,443,1194t/m1200and9090.

• Phillips screwdriver, size small.

• Slotted screwdriver, size mini < 3mm.

• Slotted screwdriver size large.

• RJ45 (8P8C) crimper.

• RJ10 (4P4C) crimper.

• Cable Tester for UTP cables.

• Internet connected smartphone, tablet or laptop.

If you wish to make the charging system future proof, then take the following attention

points into account:

• AccordingtotheMode3protocoloftheIEC62196electricvehiclesneedatleast6Ato charge

• NotethatvehicleswithaRenaultChameleoncharger(RenaultZoe)needatleast13Aon3-phaseor6Aon1-phasetocharge.

• Thenumberofelectricvehiclesthatareabletochargeat32A(1-phaseor3-phasewill increase substantially in the coming years.

01 - Voorbereidingen voorafFuse setting of charging stations

Mount Maxem on a clean, moisture-free wall. Use the supplied mounting plate and

screwsforthis.TakeintoaccountsufficientspacearoundMaxem.

01 - Mounting on the wall

Wiring at the bottom

70mm

20mm

20mm20mm

A.

Maxemisacontrolsystemthatregulatestheloadofthechargingstation.Maxemoffersan

intelligent layer of protection on top of the circuit breakers. This is done in the following way:

• When an over current is measured on the main grid connection, the power of the

charging stations is immediately adjusted downwards.

• When the over current is too high, Maxem is able to pause one or more charging

stations until more capacity is available again.

Therefore it is possible to fuse the charging stations at a higher rate than normal. All charging

stations can be fused at their maximum power capacity, but a fuse of a single charging

station may never be higher than the capacity of the main grid connection.

Maxem protects against over current

Points of attention to install future proof

1110

02 - Installing kWh-meter grid connection

Open the grid panel with the

appropriate tools.

Place the kWh-meter on a DIN rail in

the installation cabinet such that it

measures the entire grid connection

(immediately after the main circuit

breaker). Connect the power cables

according to the wiring diagram below.

Switchoff themaincircuitbreaker in

the grid panel.

A.

B.

C.

Currentflowmaingrid connection

O.OFF O.OFF O.OFF O.OFF

SETOK

1 2 3

Wiring diagram direct kWh-meter in a TN grid with neutral

Numbered

connection points

on kWh-meter

Connection RS485 cable on kWh-meter

Connect the RS485 cable on the kWh-

meter as follows:

• PortC:Greenwire

• PortB:Whitewire

• PortA:Brownwire

D.

Connect the RS485 cable to port RS1 on Maxem.

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

RS1

E.

RS1 port for kWh-meter

Set the address of the kWh meter to ‘100’. This allows Maxem to configure itself

automatically.

F.

Do not forget to set the correct address to the kWh meter. Maxem will not work properly without correct configuration of the kWh meter.

Go to menu.

Navigation through the ABB A43 / A44 kWh-meter menu

If you see this icon in the kWh meter display, there is an active data connection with Maxem.

Scroll through the menu or set value higher or lower.

Press to adjust a setting.

Press to enter a menu item or to accept an adjustment.

RS485RS485 Address

Location of the addressing function in the menu structure on the kWh-meter.

100

1312

Option 2.1 - Installing kWh-meter Plus (<80A)

SETOK

1 2 3

Ensure that the current transformers are connected in the right direction and to the correct phases on the kWh-meter. Incorrect installation can lead to over current on the grid connection.

Configureprimaryamperage*

Configuresecondaryamperage*

Primary amperagePri

Sec Secondaryamperage

Set the address of the kWh-meter to ‘100’. This allows Maxem to configure itself

automatically.

F.

Do not forget to set the correct address to the kWh meter. Maxem will not work properly without correct configuration of the kWh meter.

Location of the addressing function in the menu structure on the kWh-meter.

100

Configure theprimaryandsecondary

amperage of the current transformers

in the kWh-meter. These values can be

found on the current transformers.

F.

Location of primary and secondary values in menu structure.

Primary

value

Secondary

value

14 15

Wiring diagram of indirect kWh-meter in a TN grid with neutral.

Current transformer

Numbered

connection points

on kWh-meter

Place the kWh meter on a DIN rail in the grid panel

Protect the indirect kWh-meter with

the included 10A circuit breaker.

Connect the split-core current

transformers such that they measure

the entire grid connection (immediately

after the main circuit breaker).

Make sure that there is no dirt or grease on the inside of the closure of the split-core current transformer. This may result in inaccuracy in the measurement and thereby over current on the main grid connection.

Click the split-core current

transformers around the power

cables. Use the included tie-wrap to

secure the current transformer tightly

to the power cable.

Grid panel

Grid connection

A.

B.

C.

D.

Connect the split-core current transformers and the power supply of the 10A circuit

breaker to the kWh meter according to the diagram below.

E.

P2

P1

Note that the current direction follows the arrow on the split-core current transformer.

Option 2.2 - Installing kWh-meter Pro (>80A)

SETOK

1 2 3

500/5A

03 - Installing kWh-meter for solar panels

Connect the RS485 cable on the kWh-meter as follows:

• PortC:Greenwire

• PortB:Whitewire

• PortA:Brownwire

Place the kWh-meter on a DIN-rail in the grid panel.

Connect it such that it masures the output of the solar inverter.

A.

B.

C.

Connect the included RS485 splitter to the RS1 port on

Maxem.

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

RS1Set the address of the kWh-meter to 001. This allows

Maxem to configure itself. See appendix 2 on how to

configuretheaddress.

SETOK

1 2 3

Grid panel

Solar panels

Curr

ent d

irec

tion

Connection RS485 cable on kWh-meter

D.

F.

RS1 port for RS485 splitter

Connect the kWh-meters for both the main grid connection

and solar panels to the RS485 splitter.

E.

Connect the RS485 cable on the kWh-meter as follows:

• PortC:Greenwire

• PortB:Whitewire

• PortA:Brownwire

F.

SETOK

1 2 3

Connection RS485 cable on kWh-meter

Press for 2 seconds to access the main or go ‘up’ in the menu.

Scroll through the menu or set value higher or lower.

Press to enter a menu item or to accept an adjustment.

Press to adjust a setting.

Navigation through the ABB B23 / B24 kWh-meter menu

If you see this icon in the kWh meter display, there is an active data connection with Maxem.

Connect the RS485 cable to port RS1 on Maxem.E.

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

RS1

RS1 port for kWh-meter

16 17

Option 4.1 - Connecting KEBA charging stations

Install a circuit breaker or earth leakage circuit breaker at the maximal

power available. See page 10.

Follow the installation instructions of the charging stations. These can

be found in the installation manual of the charging station.

RouteasuitableUTP (CAT5orCAT6)cable fromall chargingstations toMaxemand

attach RJ45 connectors on both sides of the cable.

Connect the UTP cables to the Ethernet Switch and connect one of ports on the

Ethernet Switch ETH port on Maxem.

A.

B.

D.

E.

04 - Connecting charging stations

Connect the power supply of the charging stations so that the load of L1, L2 and L3 is

evenly distributed. The table below shows the standard distribution.

C.

KEBA 1

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

Maxem

Ethernet switch

KEBA 2 KEBA n

Maxem and KEBA P20 / P30s with a switch connected.

It is advisable to test the network cable with the help of a cable tester.

Set DSW 1.3 to ON. Smart charging will

be activated.

Set DIP switches on DSW1 to the maximum available power.

DSW1.6Off

DSW1.7Off

DSW1.8Off

10A

13A

16A

20A

25A

32A

See the KEBA P20 / P30 installation manual for more information.

SwitchthepowersupplyoftheKEBAP20/P30off(theDIPswitchsettingswillonlybe

activated after a charging station reset).

F.

G.

H.

DSW1 - Power (block above)DSW2 - Addressing (block below)

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

Data activity on ETH poort Maxem

Data activity on ETH poort KEBA P20 of P30

UTP-cable with RJ45 connectors

DIP switch settings for setting the maximum power.

18 19

Charging

station

Phase

distribution# 1 L1 – L2 – L3# 2 L3 – L1 – L2# 3 L2 – L3 – L1# 4 L1 – L2 – L3# 5 L3 – L1 – L2#6 L2 – L3 – L1# 7 L1 – L2 – L3# n

Standard phase distribution Maxem

Option 4.2 - Connecting ICU charging stations

Install a circuit breaker or earth leakage circuit breaker at the maximal

power available. See page 10.

Follow the installation instructions of the charging stations. These can

be found in the installation manual of the charging station.

RouteasuitableUTP(CAT5orCAT6)cablefromallchargingstationstoMaxemand

attach RJ45 connectors on both sides of the cable.

Connect the UTP cables to the Ethernet Switch and connect one of ports on the

Ethernet Switch ETH port on Maxem.

The charging station firmware may need to be updated. This can be done via ICU Connect. ICU can assist you with this.

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

Data activity on ETH port Maxem

ETH port ICU UTP-cable with RJ45 connectors

A.

B.

D.

E.

Connect the power supply of the charging stations so that the load of L1, L2 and L3 is

evenly distributed. The table below shows the standard distribution.

C.

It is advisable to test the network cable with the help of a cable tester.

ICU 1

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

Maxem

Ethernet switch

ICU 2 ICU n

Maxem and ICU charging stations connected with a switch.

Option 4.3 - Connecting EV-Box charging stations

Install a circuit breaker or earth leakage circuit breaker at the maximal power available.

See page 10.

Follow the installation instructions of the charging stations. Connect

the EV-Box Satellites to theHub in a hub-satellite configuration. The

instructions for this can be found in the installation manual of the

charging station.

RouteasuitableUTP(CAT5orCAT6)cablefromtheEV-BoxhubtoMaxem.(Toprevent

electromagnetic interference with distances greater than 25m, it is recommended to

useFTPCAT6cable.Maximumdistanceis50m).

A.

B.

D.

Connect the power supply of the charging stations so that the load of L1, L2 and L3 is

evenly distributed. The table below shows the standard distribution.

C.

Hub Satellite 1 Satellite n

Maxem and EV-Boxes in a Hub - Satellite configuration

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

Maxem

20 21

Charging

station

Phase

distribution# 1 L1 – L2 – L3# 2 L3 – L1 – L2# 3 L2 – L3 – L1# 4 L1 – L2 – L3# 5 L3 – L1 – L2#6 L2 – L3 – L1# 7 L1 – L2 – L3# n

Standard phase distribution Maxem

Charging

station

Phase

distribution# 1 L1 – L2 – L3# 2 L3 – L1 – L2# 3 L2 – L3 – L1# 4 L1 – L2 – L3# 5 L3 – L1 – L2#6 L2 – L3 – L1# 7 L1 – L2 – L3# n

Standard phase distribution Maxem

Connect the RJ10 4P4C connector to the RS2 port on Maxem.

Connect the 2 wires of the data cable to the green 4-pole Phoenix connector and

connect this connector to the designated port on the EV-Box modem:

• Connect wire 1 (orange-white) to Port A.

• Connect wire 2 (orange) to Port B.

• The remaining ports do not need to be connected.

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

RS2 port for EV-Box Hub

Diagram of the controller of the EV-Box Hub connected to Maxem.

Pin 1Pin 2

12V/DC

ABGND

Lip on top

F.

G.

RS2

Wires for strain relief

Crimp the included RJ10 4P4C connector to the data cable on the Maxem side:

• Connect wire 1 (orange-white) to Pin 1.

• Connect wire 2 (orange) to Pin 2.

• Connect two other wires as a strain relief.

E.

Connect Maxem to the Internet-connected modem or router with the included network

cable.

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

Ethernet port to Internet Router

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

Connect Maxem to a wall socket in the meter cabinet with the supplied 230V power

cable.

Check if all parts are connected to Maxem.A.

B.

C.

A

A

167

184

55.50

SECTION A-A

Client:

Rev. nr:

1:1Units:

1/2

CES-01 - Enclosure

MHVol. (mm³):

mm

Sheet:

Scale:

-

CohereDate:

Drawn:

File reference:Drawing name:

-Material:17-02-2016

Maxem 4 Assembly

A3

Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]

<0,2x45° or R<0,2

Ra 0,8 um

Default length tolerances: DIN 7168

±20'Default angle tol.:

Finish:

Default edges:

Roughness:

Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8Dim.: 0-6 7-30 31-120 121-400 401-1000

05 - Connecting Maxem

22 23

Power supply

06-Configurationandcommissioning

In case of unsuccessful installations Maxem is unable to send a power limiting value to the charging stations, resulting in OVERLOAD OF THE GRID CONNECTION. Therefore, make sure that the installation has been successful!

Turn on the charging stations or reboot them by cutting the power supply for at least

30 seconds. Wait at least 1 minute for the charging stations to boot.

Connect the 230V power to Maxem.

A.

B.

Maxemhastobeconfiguredviatheonlineconfigurationtool.Gotothewebsite

andfollowtheconfigurationsteps:

install.maxem.io

C.

LED indications on Maxem

RS2RS1P1 CT3CT2CT1

Central LED indicator

LED indicators

input/output ports

LED indication MeaningStatus

communication

LEDisoff NothingisconfiguredonMaxem -

LED is green Communication is OK.

LED is redCommunication is expected, but is not detected.

LEDflashesgreen/red

Communication detected, but is differentthanexpected.

LED indication Meaning

Burns continuously Maxem works correctly.

Flashes 4x Maxem has no Internet connection.

Flashes 2x Maxem returns to factory settings.

Flashes continuously Maxem is booting.

If you have problems with commissioning, please contact: +31 20 7708 713

Fillouttheconfigurationoftheinstallationinthetablebelow.D.

# Serial number charging station

Number of sockets*

Power per socket

Fuse Phase distribution**

Phases Amps L1 Charger

L2 Charger

L3 Charger

1 1 / 2 A 1f / 3f A

2 1 / 2 A 1f / 3f A

3 1 / 2 A 1f / 3f A

4 1 / 2 A 1f / 3f A

5 1 / 2 A 1f / 3f A

6 1 / 2 A 1f / 3f A

7 1 / 2 A 1f / 3f A

8 1 / 2 A 1f / 3f A

9 1 / 2 A 1f / 3f A

10 1 / 2 A 1f / 3f A

11 1 / 2 A 1f / 3f A

12 1 / 2 A 1f / 3f A

13 1 / 2 A 1f / 3f A

14 1 / 2 A 1f / 3f A

15 1 / 2 A 1f / 3f A

16 1 / 2 A 1f / 3f A

17 1 / 2 A 1f / 3f A

18 1 / 2 A 1f / 3f A

19 1 / 2 A 1f / 3f A

Configurationinstallation

Main grid connection Fuse: A

Sub grid panel Present*: yes / no Fuse: A

Solar panels Present*: yes / no Fuse: A

Charging station brand □ EV-Box □ ICU □ KEBA

Number of charge sockets

*Strikethrough what does not apply**Specify how the each phase is connected to each charging station. Enter the appropriate phase of the main grid connection in each of the boxes.

Completetheconfigurationofallconnectedchargingstationsinthetablebelow.E.

24 25

Providetheuserwiththemanualandthecompletedconfigurationtables.F.

# Serial number charging station

Number of sockets*

Power per socket

Fuse Phase distribution**

Phases Amps L1 Charger

L2 Charger

L3 Charger

20 1 / 2 A 1f / 3f A

21 1 / 2 A 1f / 3f A

22 1 / 2 A 1f / 3f A

23 1 / 2 A 1f / 3f A

24 1 / 2 A 1f / 3f A

25 1 / 2 A 1f / 3f A

26 1 / 2 A 1f / 3f A

27 1 / 2 A 1f / 3f A

28 1 / 2 A 1f / 3f A

29 1 / 2 A 1f / 3f A

30 1 / 2 A 1f / 3f A

31 1 / 2 A 1f / 3f A

32 1 / 2 A 1f / 3f A

33 1 / 2 A 1f / 3f A

34 1 / 2 A 1f / 3f A

35 1 / 2 A 1f / 3f A

36 1 / 2 A 1f / 3f A

37 1 / 2 A 1f / 3f A

38 1 / 2 A 1f / 3f A

39 1 / 2 A 1f / 3f A

40 1 / 2 A 1f / 3f A

41 1 / 2 A 1f / 3f A

42 1 / 2 A 1f / 3f A

43 1 / 2 A 1f / 3f A

44 1 / 2 A 1f / 3f A

45 1 / 2 A 1f / 3f A

46 1 / 2 A 1f / 3f A

47 1 / 2 A 1f / 3f A

48 1 / 2 A 1f / 3f A

49 1 / 2 A 1f / 3f A

50 1 / 2 A 1f / 3f A

Appendix 1 - Troubleshooting

• Verify that Maxem’s network connection is active. If there is an active data

connection,anorangeLEDflashesontheMaxemLANport.

• Verify that there is an Internet connection on the connected router.

• Verify that the UTP cable is properly connected using a cable tester.

• Make sure Maxem is able to make a DHCP connection to the network.

• Make sure Maxem is able make DNS requests over the network.

• RestartMaxembyturningitoffandon.AnyproblemswithIPaddressingcanbe

solved this way.

• RS485 connected charging stations: Check whether the RJ10 (4P4C) connector is

securely plugged in. See Appendix 3 how to crimp RJ connectors.

• Ethernet-connected charging stations: Verify that there is an active data connection

with the charging station (visible by a green and orange LED). If not, check whether

the RJ45 connectors are properly crimped.

• Restartthechargingstationbyturingitoffandonagain.

• MakesurethechargingstationrunsfirmwarewhichiscompatiblewithMaxem.

• Maxemsoftwareisnotconfigured.Gotothewebsiteinstall.maxem.iotorunthe

configurationtool.

• Check what the maximum charging power of the car is. For example, the Tesla Model

S requires a dual charger to charge on 3x24A. A Model S with a single charger charges

upto3x16A.

• For KEBA charging stations: Check whether the DIP switches are set correctly.

• Thefuseforthechargingstationissettoolowortoohighintheconfigurationof

Maxem. A Cohere employee can help you to customize this.

Maxem does not connect to the online back end

The charging station is not detected or not detected correctly

The car charges too slow or too fast

26 27

*Strikethrough what does not apply**Specify how the each phase is connected to each charging station. Enter the appropriate phase of the main grid connection in each of the boxes.

• The kWh-meter(s) have to be set correctly. If the address is not set correctly, the

Maxem install wizard will not recognize the kWh-meter.

• Iftheaddressissetat16andcannotbechanged,thisindicatesthattheprotocol

settings are incorrect. Make sure the kWh-meter is set as follows: Protocol: Modbus.

Parity:Even.Baudrate:19200.

• The kWh-meter is not connected correctly to the power supply. This can also be seen

on the display of the kWh-meter where the kWh value does not go up. Connect the

power supply to the kWh-meter correctly.

• The phase distribution of the power supply of the charging stations is not correctly

configuredonMaxem’s.Checkthephasedistributionandcommunicatethisto

Cohere.

• Restartthechargingstation(powerofftheMCB,wait10seconds,thenpowerupthe

MCB again). Make sure the charging cable is not connected to the car.

• EV-Box • Thechargingstationisrunningonoutdatedfirmware.Contact

EV-Boxforafirmwareupdate.Restartthechargingstationafter

the update.

• Maxem set a power value outside of the the charging stations

range.MakesuretheEV-Boxissettoatminimum6Aand

maximum to the fuse of the charging station.

• ICU • Thechargingstationisrunningonoutdatedfirmware.Contact

ICUAlfenforafirmwareupdate.Restartthechargingstation

after the update.

• There is an authorization issue so that the charging station does

not receive permission to start a charging session. Contact ICU

Alfentoconfigurethisonline.

• KEBA • The charging station is not set smart charge ready. Make sure DIP

switch 1.3 is turned on.

• Tesla Wall

Connector

• The charging station is not set to Slave (F mode). The red LED

indicatorflashes4xontheWallConnector.SetittoSlave(F

Mode).

The values in the web portal are not logical

One or more cars do not start charging

28 29

Maxem is able tomeasure different devices using an externalMID certified kWhmeter.

In order for the communication to function correctly, the kWh-meter must be set to the

corresponding address. Here’s how to do this:

Location of the addressing function in the menu structure.

SETOK

1 2 3

Number of devices

Type of device

Standard addressing on kWh-meter

Appendix2-Configuring65AkWh-meter

Node Address

Main grid connection 100

Solar #1 001

Solar #2 011

Charging station #1 002

Charging station #2 012

Heat pump #1 004

Heat pump #2 014

Example addresses

Node Address

Main grid connection 100

Solar 001

Charging station 002

Heat pump 004

Device

Press for 2 seconds to access the main or go ‘up’ in the menu.

Scroll through the menu or set value higher or lower.

Press to enter a menu item or to accept an adjustment.

Press to adjust a setting.

Navigation through the ABB B23 / B24 kWh-meter menu

If you see this icon in the kWh meter display, there is an active data connection with Maxem.

234

1

TroubleshootingAppendix 3 - Crimping RJ-connectors

30

Required tools and material

• Crimping pliers (suitable for RJ10 and / or RJ45 plugs)

• Scissors or cutters

• Sharp (Stanley) knife

• RJ10 or RJ45 plugs

Steps

Cut the wires in a straight line with a pair of pliers in order to have them all with the

same length.

Strip approximately 3 cm of the outer cover with a sharp (Stanley) knife. The individual

wires should not be damaged.

A.

B.

Insert the wires into the RJ10 or RJ45 connector. Make sure that the wires are placed in

the correct order. For the RJ10 connector it is recommended to place 2 additional wires

for strain relief.

C.

Make sure that the wires are inserted deep enough into the connector in order to have

themfirmlyfixed.

D.

Place the connector with the inserted cable into the pliers. Clench it in order to have

thewiressecuredandexposed. Itmaybenecessary toclench thepliersfirmly two

times or more.

E.

Double-check that all cores are fully inserted. If this is not done correctly, the cable

will not work properly.1234

12345678

4P4C (RJ10)

Lip on top side

8P8C (RJ45)

Lip on top side

Connection diagram

Wires for strain relief

We,

Cohere Energy Solutions B.V.Willem de Zwijgerlaan 3501055 RD Amsterdam, Nederland

following the provision of the following EC Directives:• 2006/95/ECTheLowVoltageDirective• 2004/108/EEC The Electromagnetic Compatibility Directive

Hereby declare that the product: Maxem Energy Manager 4.0 is in conformity with the applicable requirements of the following documents:

Emissions• EN61326-1(2013)• EN61000-3-2(2006)+A1(2009)+A2(2009)• EN61000-3-3(2008)

Immunity• EN61326-1(2013)

Safety• EN61010-1(2010),• EN61010-2-030(2010)• EN61010-2-023

Signee Date Place Signature

Jan Willem HeinenCEO

1August2016 Amsterdam

TroubleshootingEU Declaration of Conformity

31

C H A R G E S M A R T E RWillem de Zwijgerlaan 350 | 1055 RD | Amsterdam | The Netherlands+31(0)207708713|[email protected]|www.cohere.eu