installation manual - geberit · montageanleitung instructions de montage istruzioni per il...

8
Montageanleitung Instructions de montage Istruzioni per il montaggio Geberit Duofix Installation Manual Installation Manual

Upload: vandiep

Post on 04-Jun-2018

222 views

Category:

Documents


3 download

TRANSCRIPT

MoInsIstr

Geberit Duofix

InMInM

stallation anualstallation anual

ntageanleitungtructions de montageuzioni per il montaggio

Product DataSystembeschreibung

996.506.00.0

Product Specifications

Geberit Model No. / Flush volume:• 111.335.00.5 / 1.6/0.8 gpf (6.0/3.0 lpf)• 111.902.00.5 / 1.28/0.8 gpf (4.8/3.0 lpf)

Concealed tank and bowl carrier, wall-hung two-hole toilet bowl and actuator plate.

Tank and carrier system shall fit within a minimum 5 1/2" (140) deep wall with studs placed 19 3/4" (500) apart, water supply shall be 1/2" copper, minimum water pressure 35 PSI. The bowl shall be an IAMPO listed wall-hung bowl to match flush volumes shown in table. The carrier shall have adjustable height for 15" (381) to 19" (483) bowl rim height. Actuator plates shall be die-cast zinc, plastic or stainless steel and plated to preserve the material’s integrity.

Features

• Square structural 16 gauge powder coated steelframe

• Actuator dimension: 9 5/8" (254) width6 1/2" (165) height

• Carrier height adjustable range 15" (381) to 19"(483) bowl rim height

• Impact resistant high density polyethylene tankHDPE

• Insulated to prevent condensation• Anti-siphon fill valve meets ANSI / ASSE 1002-99

standard

Warranty996.506.00.0

Limited lifetime warranty on tank and carrier.

10 year warranty on fill valve and flush valve.

One year warranty on actuator plate.996.506.00.0

Masse Geberit Duofix Element für Wand-WC, 112 cm, mit Sigma Unterputzspülkasten 12 cm

996.506.00.0

Material Determination

Recommended material for wall surface construction:

• Gypsum / green board• Cement board• Tile backer board• Ceramic tile surface

Options

FF

3" (75)4" (100)

5⁄₁₆"(135)

7⁄₁₆"(180)

X

Wall thickness not to exceed 3"

min 4"(100)

7¾"(195)

71/8"–9"(180–230)

2"(50)

2"(50)

4"(100)

X12"–16"

(305–407)

47"–51"(1195–1297)

19¾"(500)

26⅜"(670)

4¾"(120)

2⅜(60)

22"(558)

100NPT½"

3½"–5³⁄₁₆"(90–135)

Stud FrontCenter Pipe

FRH

FF

Finishd Rim Height (FRH)FRH = X plus 3"

Vertical discharge elbow 3" DWV standard- Horizontal left: 366.914.16.1- Horizontal right: 366.913.16.1

Sigma01 Dual flush actuator; white 115.770.11.5Sigma01 Dual flush actuator; chrome 115.770.21.5

Tango Single flush actuator; chrome 115.760.21.1

Sigma10 Single flush actuator; withe 115.758.KL.5

Sigma20 Dual flush actuator; white 115.778.KH.1

Sigma50 Dual flush actuator; white 115.788.11.5

Sigma01

Tango

Sigma20

Sigma10

Sigma50

Wall anchoring set for single installation 111.815.00.1

2 © 06-2017 968.074.00.0 (00)

InstallationMontageregeln996.506.00.0

Installation Requirements

To install tank and carrier, a 2 x 6" wood frame or metal frame construction is required. Studs must be placed 19 3/4" apart (clearance) where carrier will be positioned inside the wall.

Bowl Finished Rim Height (FRH)

Remove carrier and installation hardware from its box. Determine FRH for wall-hung bowl and adjust carrier height in accordance with requirement. Dimensions can be taken from bowl or carrier specification sheet. Be sure to allow for finished floor and sole plate height.996.506.00.0

Discharge elbow installation

1

2

3

4

3½"–4¾"(90–120)

3¹⁄₈"–5³⁄₁₆"(105–135)

31/2"-43/4"(90-120)

41/8"-53/16"(105-135)

41/8"-53/16"(105-135)

A B

C D

E F

3© 06-2017 968.074.00.0 (00)

Tank and carrier installation

1 Locate carrier supporting studs andreinforce with additional nails. Ensure rough-in for the carrier is plumb and square. Wall framework must be affixed to the floor and ceiling for maximum support.

2 Position carrier unit in the prepared opening. Carrier face plate must be flush with the front of the surrounding studs so that maximum support for the wall sheeting (applied later) will be accomplished. With carrier still in place, mark all anchor and bolt hole locations on sole plate and studs. Mark location for the 3" DWV discharge pipe.

3 Pull out carrier from framework and drill six(6) pilot holes (3/16") for the supplied lagscrews where marked on sole plate. Alsodrill six (6) bolt holes (5/16") where markedon both studs. Use hole saw and bore a 4"hole through sole plate and floor for thedischarge stop out pipe.

4 Install 3" DWV waste pipe through floor andconnect to waste line (i.e. PVC, copper, cast iron).

5 Set carrier unit sideways back intoframework and bolt in place with hardware provided.

6 Complete waste elbow connection with 3"DWV shielded coupling (D - provided) to waste pipe.

7 Install two (2) 1/2" x 6" fixture support rodswith plastic sleeves (A), yellow pipe caps (B) and mud guard (C) for protection during wall surface construction.

0°−45°0°−45°

For finishing the installation of bowl and actuator plate see detailed instructions.

12"–16"

F.F.

47"–51"

A Install ½" rods with plastic sleeves,B pipe plugs andC mud guard during the rough-in installationD Complete waste elbow connection with 3" DWV

shielded coupling (D - provided) to waste pipe.

19 ¾"

⁵⁄₁₆"

⁵⁄₁₆"

C

A

B

D

4 © 06-2017 968.074.00.0 (00)

Water supply installation

1

2

3

4

5

NPT 1/2" elbow

R ½''

R ½''

5© 06-2017 968.074.00.0 (00)

6

7

8

9 Install wall surface material such as highdensity Gypsum / green Board, Cement Board, Tile Backer Board with optional ceramic tile finish surface as the most suitable materials. Provide cut outs for the protruding parts like inlet and outlet pipes and the rectangular access box.

2

1

99

6.1

08

.00

.0 (0

0)

Montageanleitung

Instructions de montage

Istruzioni per il montaggio

Installation

Manual

6 © 06-2017 968.074.00.0 (00)

Bowl installation

1 Remove yellow protection plugs and sealsfrom pipes.

2 Insert discharge pipe into the pipe hub in the wall. Place a straight edge flush against the wall and mark a line on the pipe. Fit finned rubber seal onto flush pipe. Repeat same procedure for discharge pipe.

3 Place discharge pipe with gasket into waste outlet of bowl. Also place flush pipe with fin gasket into inlet of bowl. Then mark a second line on both pipes.

4 Add dimension X and 1/8". Using thatdimension, mark a line on the pipe measuring from the hub side. Cut off the pipe at the line with a pipe cutter.

5 Add dimension Y and 1/8". Using thatdimension, mark a line on the pipe measuring from the hub side. Cut off the pipe at the line with a pipe cutter.

6 Bevel the sharp edges as shown to assure asmooth insertion into the pipe hubs in the wall.

7 Install both seals into the pipes in the wall.Lubricate seals with appropriate rubber seal lubricant.

1

1

2

22

2

1

1

2

2

1

1

1

2

X

X+1/8"+(3 mm)

Y

+1/8"+(3 mm)

Y

12

7© 06-2017 968.074.00.0 (00)

Geberit International AG, Schachenstrasse 77, CH-8645 JonaT +41 55 221 63 00F +41 55 221 63 16

[email protected]➔ www.geberit.com

8 Remove protective sleeves from mountingrods. Determine protruding rod length for bowl installation. Install both pipes into the hubs in the wall.

9 Place bowl onto rods. Attach cap washerwith nose up and facing forwards onto rods. Install washer and hex nuts, tighten loosely. Level bowl. Tighten hex nuts. Snap on the bolt caps.

10 Seal gap around bowl with waterproofsealant.

Contact

Geberit2100 Clearwater Drive, Des Plaines, IL 60018-5999

Phone: (847) 803 5000 • Fax: 847/803-5454For Technical Assistance: 800 / TEC-TRUE (800-832-8783)

➔ www.geberit.us

CAUTIONHigh torque forcesWC ceramic appliance may break

Do not overtighten hex nuts.

Sound insulation pad is optional or required.

1+13/16"+(20 mm)+13/16"+(20 mm)

2

2

2

2

1

AA

AA

8 © 06-2017 968.074.00.0 (00)