1 Ceiling Void Shower Low Ceiling Install: E3 Fixed - HA3 SD2 OC1 E3 Flex - HA3 SF2 OC1 Regular Ceiling Install : E3 Fixed - HA3 SD2 OC3 E3 Flex - HA3 SF2 OC3 Important Installer — This product manual is the property of the customer and must be retained with the product for maintenance and operational purposes Part No. 24004 Issue: Oct 2018 Installation Manual This shower must be used with compatible TMV3 shower mixer/valve or timed flow control valve

Upload: trinhdien

Post on 13-Aug-2019

227 views

Category:

Documents


0 download

TRANSCRIPT

1

Ceiling Void Shower

Low Ceiling Install: E3 Fixed - HA3 SD2 OC1E3 Flex - HA3 SF2 OC1

Regular Ceiling Install : E3 Fixed - HA3 SD2 OC3E3 Flex - HA3 SF2 OC3

ImportantInstaller — This product manual is the property of the customer and must be retained with the product for maintenance and operational purposes

Part No. 24004 Issue: Oct 2018

Installation Manual

This shower must be used with compatible TMV3 shower mixer/valve or timed flow control valve

2

Table of Contents

Important safety informationDescriptionSystem diagramSpecificationInstallation variationsSiting the showerInstallation

1. Control Hub2. Low Ceiling Compact3. Regular Ceiling Compact

Electrical installationFactory settingsTroubleshootingOperationMaintenance/CleaningSpare partsCustomer care

3 -4 -5 -7 -9 -10 -11 -11 -12 -13 -14 -15 -16 -16 -17 -19 -21 -

Product code description

Control Hub Shower head Hose set Compact Style

E3 Fixed HA3 SD2 OC1E3 Flex HA3 SF2 OC1

-1= 19mm Air outlet 2= 16mm Air outlet3= Remote flow sensor

# Indicates:1: Long pipes2: Short Pipes

1= Compact hose set

System Description

E3 Fixed -

• Fixed shower head mounted onto compact then onto rear service void wall

• Ceiling void mounted Control Hub• Optional air recirculation• Shower activation via water flow sensor

E3 Flex -

• Directional shower head mounted onto compact then onto rear service void wall

• Ceiling void mounted Control Hub• Optional air recirculation• Shower activation via water flow sensor

NOT INCLUDED:• (x2) 22mm Chrome pipe

3

Important safety Information

This product is not a substitute for a shower control (Mixer/

valve).

This product is not an electric shower.

Products manufactured by Kelda Technology are safe and

without risk provided they are installed, used and maintained

in good working order in accordance with our instructions

and recommendations.

DO NOT operate the unit if the shower head becomes

damaged.

DO NOT restrict flow out of shower by placing an obstruction

in front of the shower head nozzles.

G E N E R A L

1. Read all of these instructions and retain them for later

use.

2. DO NOT take risks with plumbing or electrical

equipment.

3. Isolate electrical and water supplies before proceeding

with the installation.

4. The shower head must be mounted onto the finished wall

surface (on top of the tiles). DO NOT tile up to or seal

around ANY PART of the shower head.

5. Special care must be taken NOT TO BLOCK OR SEAL THE BACK PLATE VENT.

6. The shower head must be cleaned regularly with

descalent to remove scale and debris. The Air hoses must

be cleaned periodically to maintain performance and

hygiene. PLEASE SEE MAINTENANCE SECTION.7. This product is not suitable for mounting into steam rooms

or steam cubicles.

P LU M B I N G

1. The plumbing installation must comply with water

regulations, building regulations or any particular

regulations as specified by local water company or

water undertakers and should be in accordance with BS

EN 806 (specifications for installations inside buildings

conveying water for human consumption. Operation and

maintenance).

2. The supply pipe must be flushed to clear debris before

connecting to the shower head water inlet.

3. DO NOT solder pipes or fittings within 300mm of the

supplied hoses, as heat can transfer along the pipework

and damage components.

4. DO NOT use excessive force when making connections

to the flexible hose or shower head.

5. All plumbing connections must be completed before

making the electrical connections.

6. Ensure that the Control Hub is fitted in the ceiling void

above the shower cubicle.

E L EC T R I C A L

1. The installation must comply with BS 7671 ‘Requirements

for electrical installations’ (IEE wiring regulations),

building regulations or any particular regulations as

specified by the local electrical supply company.

2. In accordance with ‘The Plugs and Sockets etc.

(Safety) Regulations 1994’, this appliance is intended

to be permanently connected to the fixed wiring of the

electrical mains system.

3. Make sure all electrical connections are tight to prevent

overheating.

4. A 32mA residual current device (RCBO) MUST be

installed in all UK electric and pumped shower circuits.

This may be part of the consumer unit or a separate unit.

5. Other electrical equipment i.e. extractor fans, pumps

must not be connected to the circuits within the unit.

6. Switch off at isolating switch when not in use

for extended periods. This is a safety procedure

recommended with all electrical appliances.

7. As with all electrical appliances it is recommended to

have the shower and installation checked at least every

two years by a competent electrician to ensure there is no

deterioration due to age and usage.

Contact Customer Service (see back page), if any of the

following occur:

a) If it is intended to operate the shower at pressures

above the maximum or below the minimum stated.

b) If the unit shows a distinct change in performance.

4

The Kelda shower system is a ground breaking, patented technology that injects water into an air stream to deliver a unique “real rain” effect showering experience. This provides a shower force equivalent to twice that of a conventional shower, thereby offering water savings of over 50%* and associated water heating energy savings.

The Kelda shower system is designed to be used in conjunction with virtually any pre installed water valve. General arrangement — refer to diagram on page 5. The Shower head (1) is installed within the shower area against a service area wall. The Control Hub (2) is installed on the wall within the ceiling void area. A 150W-36V AC electrical supply (3) is required to be connected to the Control Hub via a 32mA RCBO device.

Water supply is plumbed to a shower control mixer/valve (not supplied). The outlet of this valve is then plumbed directly to the shower head attached to the compact. Air is supplied to the shower head from the air outlet connection of the Control Hub with the hose supplied.

Description

* Refer to University of Southampton report at www.keldatechnology.com

Diagram of Control Hub

Fan speed: UP/DWN

Timer settings: UP/DWN

Backplate Casing

19mm Air Inlet 19mm Air Outlet

36V Power Supply Cable Flow sensor extension cable

Blower

Power In Terminal

Main PCB

5

System diagram

Shower control Mixer/ Valve

220-240V Mains electricity supply via the LPV150W-36V AC Transformer (supplied)

Low voltage 36V electrical link

3

Air supply from Control Hub to shower head via hose supplied

Blended supply water from mixer/valve to shower head

(Regular Ceiling E3 Fixed head)

32mA RCBO

Shower headSD2

1

Control HubHA3

2

Ceiling Void Area

Cubicle AreaRear Void Area

Air in hose length 150mm as re-circulation is not optional

Water feed points: Top fed, Back fed & Bottom fed

Remote flow sensor cable

6

System diagram

Shower control Mixer/ Valve

220-240V Mains electricity supply via the LPV150W-36V AC Transformer (supplied)

Low voltage 36V electrical link

3

Air supply from Control Hub to shower head via hose supplied

Blended supply water from mixer/valve to shower head

(Low Ceiling E3 Flex head)

32mA RCBO

Shower headSF2

1

Control HubHA3

2

Ceiling Void Area

Cubicle AreaRear Void Area

Air in hose length 150mm as re-circulation is not optional

Remote flow sensor cable

Water feed points: Top fed, Back fed & Bottom fed

7

The Kelda HA3 SD2 OC1 contents (E3 Fixed head)

1

You should have the following assemblies within your E3 Fixed order:

SD2 - Shower Head

2 OC1 - Hoses

3 HA3 - Control Hub

• x1 Bright chrome Fixed shower head

• x1 Fixing Kit: x2 Fixing flange nuts x2 Pre-cut Poly washers

• x1 Control Hub• x4 Screws• x4 Wall plugs• x1 LPV 150-36V Power

supply• Remote flow sensor

Specification

77mm 174mm

267m

m

Transformer

300mm 1500mm

High Voltage Low Voltage

125mm 114mm

1 m

150mm

1m (Cut to required length)

Strainer sub-assembly

Insert strainer here

Water Feed into compact

Layflat 10mm pipe

• x1 Air Inlet hose (From void area to Control Hub) • x1 Air supply hose (from Control Hub to shower

head)• x1 Water inlet hose (from water feed to

Compact)• x2 Jubilee Clips • Strainer Sub-Assembly -x1 15mm Compression female -x1 Water connector nipple -x1 Strainer -x1 Copper to Iron 90° -x1 Elbow speedfit 0.5” to 10mm• Air Connector Assembly -x1 90° elbow 19mm -x1 3/4 Inch Air nut -x1 Jubilee Clip -x1 19mm Silicone air hose

8

The Kelda HA3 SF2 OC1 contents (E3 Flex head)

1

You should have the following assemblies within your E3 Flex order:

SF2 - Shower Head

3 HA3 - Control Hub

• x1 Bright chrome Directional shower head

• x1 Fixing Kit: x2 Fixing back nuts x2 Pre-cut Poly washers

• x1 Control Hub• x4 Screws• x4 Wall plugs• x1 LPV 150-36V Power

supply• Remote flow sensor

Specification

103mm 127mm

77mm 174mm

267m

m

Transformer

300mm 1500mm

High Voltage Low Voltage

2 OC1 - Hoses

1 m

150mm

1m (Cut to required length)

Strainer sub-assembly

Insert strainer here

Water Feed into compact

Layflat 10mm pipe

• x1 Air Inlet hose (From void area to Control Hub) • x1 Air supply hose (from Control Hub to shower

head)• x1 Water inlet hose (from water feed to

Compact)• x2 Jubilee Clips • Strainer Sub-Assembly -x1 15mm Compression female -x1 Water connector nipple -x1 Strainer -x1 Copper to Iron 90° -x1 Elbow speedfit 0.5” to 10mm• Air Connector Assembly -x1 90° elbow 19mm -x1 3/4 Inch Air nut -x1 Jubilee Clip -x1 19mm Silicone air hose

9

Top Fed, Bottom Fed, Back Fed

1 Top Fed

2 Bottom Fed

2 Back Fed

• x2 22mm Chrome pipe • x1 19mm (ID) silicone hose to connect 90°

Air elbow connector with chrome pipe• x1 10mm (ID) layflat water pipe

Flow Regulator fitted in rear of Showerhead

• x2 22mm Chrome pipe • x1 15mm Chrome pipe• x1 19mm (ID) silicone hose to connect 90° Air elbow

connector with chrome pipe• x1 10mm (ID) layflat water pipe• x1 Flow sensor• x2 0.5” to 10mm Pushfit• x1 10mm Elbow Speedfit• x1 Strainer• x1 Copper to Iron 90° 15mm to 1/2”• x1 15mm Compression 0.5” BSP Female • x1 Water connector nipple

Flow Regulator fitted in rear of Showerhead

• x2 22mm Chrome pipe • x1 15mm Chrome pipe• x1 19mm (ID) silicone hose to connect 90° Air elbow

connector with chrome pipe• x1 10mm (ID) layflat water pipe• x1 Flow sensor• x2 0.5” to 10mm Pushfit• x1 10mm Elbow Speedfit• x1 Strainer• x1 Copper to Iron 90° 15mm to 1/2”• x1 Water connector nipple

Flow Regulator fitted in rear of Showerhead

Installation variations

*Installation variation can be differerent depending on pre-existing fitting on wall. Contact Customer Service (see back page) for more information.

10

Siting the shower

Tools needed for the job

Warning!

!• The Control Hub should not be installed in an outdoor environment, including sheltered

areas.• Do not install the power supply directly beneath the water inlet adapter.• When the Control Hub is installed, the RCBO switch must be within easy reach.• Do not use extensions or multiple sockets• The power supply cable must never be bent or dangerously compressed• Only use the supplied power supply.

Fig. 4 Low Ceiling (E3 Flex)

300m

m

2000

mm

1850

mm

900m

mInstallation should be completed to suit the user’s

requirements.

Typical Height of Shower control Mixer/ Valve

Area to install Compact

Compact sized accordingly

Minimum height required for ceiling void installation.

Min/Max Area to install shower head

Fig. 5 Regular Ceiling (E3 Fixed)

300m

m

2000

mm

1850

mm

900m

m

Installation should be completed to suit the user’s requirements.

Typical Height of Shower control Mixer/ Valve

Area to install Compact

Compact sized accordingly

Minimum height required for ceiling void installation.

Min/Max Area to install shower head

11

Installation

Control Hub

Remove the cover of the Control Hub retaining the screw at the bottom. Lift off the cover and put in a safe, dry place. The wire from the cover to the circuit board should be disconnected at the circuit board side.

1

Select the position for the Control Hub referring to Fig.5/6.Locate the four screw holes and mark onto wall being drilled.

2

Drill the holes for the screws to go into the wall. Screw them into place with the Control Hub mounted on the wall using a screwdriver.

3 4

Once the compact shower head assembly has been installed then the electrical installations can be completed, including connecting remote flow sensor. The cover can now be screwed back onto the Control Hub. Re-attach LED cable to circuit board before closing cover back onto Control Hub!

Remember!When removing Control Hub lid, make sure the LED cable is disconnected from the circuit board.

Failure to do this may result in damage to the circuit board. Always check for hidden pipes + cables before drilling.

STEP 1

STEP 2

!

Ceiling Void Area

Ceiling Void Area Ceiling Void Area

Ceiling Void Area

12

Mark the position for the compact back plate screw holes on the cubicle wall by placing it flush with the ceiling. Drill the holes and fix with screws supplied. Push through the flanges at the top of the compact so the x2 22mm Chrome pipes can fit through them. Make sure it is the outer pipe holes which are bent clear.

Place the shower head into the compact fascia plate and secure using the nuts supplied. Fix remote flow sensor assembly to 1/2” BSP water inlet and 90° elbow connector to 3/4” air inlet. The flow regulator (supplied separately) should be inserted into rear of the showerhead (See Specification).

STEP 1

STEP 2

1 2

Mark the position for the compact back plate screw holes on the cubicle wall by placing it flush with the ceiling. Drill the holes and fix with screws supplied.

Place the shower head into the compact fascia plate and secure using the nuts supplied. Fix remote flow sensor assembly to 1/2” BSP water inlet and 90° elbow connector to 3/4” air inlet. The flow regulator (supplied separately) should be inserted into rear of the showerhead (See Specification).

STEP 1

STEP 2

Remember!Always check for hidden pipes + cables before drilling.

Before connecting hoses flush water inlet pipes with roughly 12 Litres worth of water to reduce risk of blockage from debris in pipes.

Compact Installation (Low & Regular Ceiling)

1 2

!

STEP 1

STEP 1

STEP 2

STEP 2

13

Thread the flow sensor cable and 10mm water pipe through one of the 22mm chrome pipes. Connect the air hose to the 90° elbow connector and secure with jubilee clip. Connect the mixed water feed using the 1/2” elbow to push fit and flexible hose supplied.

Remember!Always check for hidden pipes + cables before drilling.

Before connecting hoses flush water inlet pipes with roughly 12 Litres worth of water to reduce risk of blockage from debris in pipes.

Screw the fascia plate with the shower head and hoses attached, to the back plate.Connect the supply air hose and short air supply hose to the Control Hub and secure with jubilee clip. Ensure all air connections are airtight.

Hose Installation

3 4

!

Thread the flow sensor cable and 10mm water pipe through one of the 22mm chrome pipes. Connect the air hose to the 90° elbow connector and secure with jubilee clip. Connect the mixed water feed using the 1/2” elbow to push fit and flexible hose supplied.

Screw the fascia plate with the shower head and hoses attached, to the back plate.Connect the supply air hose and short air supply hose to the Control Hub and secure with jubilee clip. Ensure all air connections are airtight.

3 4

14

Electrical Installation

Warning!

!

1. Thread the power supply cable through the 16mm cable gland in the bottom left of the Control Hub.

2. Thread the cable into the 36V power in terminal (Order/position of leads into the terminal is not important).

3. Using a 3mm screw driver, tighten the screws down onto the wires to secure the power connection.

1. Thread the flow sensor extension cable through the 16mm cable gland in the bottom right of the Control Hub.

2. Insert the cable into the correct connector on the PCB.

The Control Hub requires a 230-240 VAC, 47 ~ 63Hz single phase supply. A 32mA RCBO should be used for each Control Hub.

All electrical installation to be carried out by an approved electrician in accordance with Part “P” U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations in the country of installation.

Electrical connectionBefore connecting to power supply, make sure that:

• The mains terminal is earthed and in compliance with the applicable law• The mains terminal is able to sustain the shower’s maximum power load indicated on the technical data plate fixed to the

Control Hub• The supply voltage is included within the values indicated on the technical data plate fixed to the Control Hub

Before installation, please read the following instructions.

• The Control Hub should not be installed in an outdoor environment, including sheltered areas.

• Do not install the power supply underneath the water inlet adapter.• When the Control Hub is installed, the RCBO switch must be within easy reach.• Do not use extensions or multiple sockets• The power supply cable must never be bent or dangerously compressed• Only use the supplied power supply.

15

Factory settings

Your Kelda shower’s flow rate is set via a flow regulator fitted within strainer and flow regulator assembly. This is shipped separately to the site specific showers depending on what flow rate is required and what water pressure your system is running at.

Water flow rate

Air volume

A i r o ve r ru n fu n c t i o n

The system has an air overrun function which allows the air to continue to operate for approximately 1-2 seconds after the water flow stops. This function purges the water from the shower head, reducing the build up of lime-scale.

The rate at which the air is delivered to the shower will automatically modulate as water flow changes to maintain optimum water/air ratio. However when commissioning the shower, the air flow rate has to be set to take into account site variations, or changed to suit the user’s requirements.

Changing the fan speed (10 settings)

• The factory setting is set at 7 • Press Speed DWN once, the number of LED flashes next to the button indicate what fan speed setting the Control

Hub is currently set at. (There are 10 speed settings: 1-10)

1. Speed UP button2. Speed Down Button

16

Symptom Likely cause Action/RemedySystem does not operate: Electricity supply (the standby power

LED is not illuminated).Check power supply is connected properly and electricity is turned on.

Fuse blown/RCBO tripped indicatingpossible electrical fault.

Check group fuse box/RCBO and replace if necessary, contact customer services if problem continues.

Water isolation valve. Turn on valve.

Shower mixer/valve not functioning. Check valve, replace if necessary.

Power is on but LED not illuminated:

Wire has disconnected from correct terminal/Fuse has tripped.

Open Control Hub’s front cover and check wire from PCB to cover is properly connected/ Check group RCBO.

Water flows from shower head but no shower spray:

Electricity supply (the standby power LED is not illuminated).

Check power supply is connected properly and electricity is turned on.

Conduct “hard reset” by switching electricity off, wait 10 seconds, switch electricity on.

Air hose disconnected. Make sure air hose is connected properly refer to HOSE INSTALLATION for help.

Kink in air hose. Make sure air hose is unkinked with a steady bend (NO SHARP CORNERS).

Temperature fluctuating: Group thermostatic control/Boiler issue.

Check thermostatic mixer valve/boiler for an issue, call a specialist if necessary.

Poor/no water flow: Blocked water filter/strainer. Disconnect water inlet hose, remove and clean filter, replace filter.

Water flow too strong: Flow regulator not installed. Check if the flow regulator is properly installed (In the shower head water inlet).

Operation1. Turn on the water isolation valve.

2. Turn on the electricity supply.

3. Check the Control Hub for power. (The Kelda Logo power indicator should be illuminated).

4. The Kelda Technology system operates by detecting water flow. It starts when water flow is detected and stops

when the water flow ceases.

5. Open the shower mixer/valve. Water should start to flow from the shower head, followed very quickly by the air

flow. Once the water valve times out, the water will cease to flow and the air will continue to operate briefly. This

purges water from the shower head.

Congratulations, you’re now ready to experience the greenest shower in the world and start saving water and energy costs.

Troubleshooting

17

Kelda Technology products are precision-engineered and should give continued superior and safe performance, provided:

1. They are installed, commissioned, operated and maintained in accordance with this installation guide.2. Periodic attention is given as necessary to maintain the product in good functional order.

Guidelines for frequency are given below. Maintenance must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. Components are precision-made, so care must be taken during maintenance to avoid damage.

Daily/ Weekly hygiene

External surfaces of the shower head/ compact may be wiped clean with a soft cloth and if necessary, a mild detergent or soap solution can be used.

Quarterly hygiene*

Shower heads to be dismantled to clean, de-scale and sanitise removable parts, heads and inserts. Please see instructions for dismantling and reassembling head for cleaning.*If showers are in a high usage area or where the water feed to showers has high hardness levels this will be required more frequently.

Six monthly visual & hygiene

Check internal component condition of the shower head and hoses. Inspect for debris, scale deposition, deformation, damage, etc. Maintain or renew if necessary. Please see Instructions for cleaning and disinfection of air hose and Control Hub

Maintenance

1. Remove the fascia plate screw cap with a small flat head screwdriver(1)

2. Remove centre screw using a posi-drive PZ2 ensuring the fascia plate (2) and atomisation engine (3) are held until screw removed.

3. Slowly lower fascia plate and atomisation engine.

4. Carefully detach the rubber hose from the water chamber (4) ensuring not to remove the hose from the other end.

5. Carry out clean, de-scale and sanitisation of shower head components in line with our maintenance guidelines.

6. To reassemble, follow steps in reverse.

Instructions for dismantling and reassembling head for cleaning

18

C l e a n i n g a n d d i s i n fe c t i o n o f a i r h o s e s

• Isolate power supply to Control Hub.• Remove air supply hose by loosening jubilee clip and gently easing hose off the air outlet adapter.• Remove 90° elbow connector by unscrewing ¾” Air nut and loosening the jubilee clip and gently pulling apart.• Remove air return hose by loosening jubilee clips and gently easing hose off the air inlet adapter and

backplate vent.• Put aside all hose clips in a safe place.• Whilst wearing the correct safety equipment, dip hoses into a disinfectant solution so all the hoses are

submerged.• Remove from solution and clean out hoses using a pipe cleaning brush.• Dip hoses into disinfectant solution and flush through, continue this until hoses are clean.• Once hoses are clean, flush hoses through with fresh water.• Shake out any excess water and wipe dry.• Replace air supply hose by gently inserting into air outlet adapter and tightening jubilee clip.• Replace 90 degrees elbow connector by gently inserting into hose, screwing ¾” Air nut onto shower head hose

pipes and tightening jubilee clip. • Repeat steps for air return hose in reverse for air recirculation installations.• Reinstate power supply to Control Hub.• Run shower for 2-3 minutes to dry any moisture in the hoses.

Warning!

! During regular cleaning of the shower area, do not direct a water hose at the shower head while the shower is functioning. Many household and industrial cleaning products contain mild abrasives and chemical concentrates and should not be used on this product.

Maintenance

19

Spare parts

No. Part No. Description Parts List

01 79046 HA1/2/3 replacement front cover Front cover, LED insert

02 80024 HA3 replacement control hub complete unit

PCB, Fan duct, Backplate casing, Air inlet, Flow sensor, HA1 - 19mm Air outlet

03 35017 19mm 1000mm Air hose 19mm 1000mm Air hose

04 35017 19mm 150mm Air hose 19mm 150mm Air hose

1. HA1/2/ 3 Control HubFront Cover

2. HA3 Control Hub

3. 19mm Air Hose

20

Spare parts

No. Part No. Description Parts List

01 80023 E3 Flex Shower head replacement Body, Body trim, Head chassis, Head top cover, Water connector, Air connector

02 80001 E3 Fixed Shower head replacement pack Backplate vent, Shower head chassis, Water connector, Air connector, Water chamber, (E3 Fixed) Atomiser engine, (E3 Fixed) Fascia plate, (E3 Fixed) Screw cap

03 80026 E3 Flex/Handset Re-fresh replacement pack Water chamber,(E3 Flex/Handset) Atomiser engine, (E3 Flex/Handset) Fascia plate, (E3 Flex/Handset) Screw cap

04 80027 E3 Fixed Re-fresh replacement pack Water chamber, (E3 Fixed) Atomiser Engine, (E3 Fixed) Fascia plate, (E3 Fixed) Screw cap

05 79060 E3 Flex/Handset Atomiser engine (E3 Flex/Handset) Atomiser Engine

06 79036 E3 Fixed Atomiser engine (E3 Fixed) Atomiser engine

05. E3 Flex/ Handset Atomiser Engine

03. E3 Flex/HandsetRe-fresh pack

01. E3 Flex Shower head

06. E3 Fixed Atomiser Engine

04. E3 FixedRe-fresh pack

02. E3 FixedShower head

21

Warning!

!• The Control Hub should not be installed in an outdoor environment, including sheltered areas, • When the control box module is installed, the mains socket must be within easy reach• Do not use extensions or multiple sockets• The power supply cable must never be bent or dangerously compressed• Only the supplied power supply should be used with the product.

C u s to m e r c a re

G u a ra nte e

Kelda Technology guarantees this product against any defect in materials or workmanship for the period of two years from the date of purchase. To be covered by this guarantee, service work must only be undertaken by Kelda Technology or by its approved agents.

N o t c o ve re d by t h i s g u a ra nte e

Damage or defects arising from incorrect installation, improper use or failure to maintain in accordance with the instructions in this product manual, including the build-up of lime-scale. Defects or damage if the product is taken apart, repaired or modified by a person not authorised by Kelda Technology or by their approved agents.

A f te r - s a l e s s e r v i c e

Our fully trained staff are ready to provide assistance, should you experience any difficulty operating your Kelda Technology equipment.

S p a re p a r t s

All functional parts of Kelda Technology products are available. All spares are guaranteed for 12 months from date of purchase. Spares that have been supplied directly from us can be returned within one month from date of purchase, providing that they are in good order and the packaging is unopened. Note: returned spares will be subject to a 15% restocking charge and authorisation must be obtained from Kelda Technology before return.

C u s to m e r c a re p o l i c y

If within a short space of time of installation the product does not function correctly, first check with the operation and maintenance advice provided in this installation guide to see if the difficulty can be overcome. Failing this, contact your installer to make sure that the product has been installed and commissioned in full accord with our detailed installation instructions. If this does not resolve the difficulty, please contact Kelda Technology, who will give you every assistance.