installation instruction munit pole clamp...munit pole clamp is used together with munit base mount...

8
1 1/221 06-SXK 107 2862/1 Uen Rev A © Ericsson AB 2013 Ericsson AB SE-126 25 Stockholm, Sweden Telephone +46 8 719 0000, Fax +46 8 18 40 85 www.ericsson.com INSTALLATION INSTRUCTION mUNIT POLE CLAMP mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures of various size and shape. All Enquiries: tel: +44 (0)1744 762 929 email: [email protected] web: www.etechcomponents.com

Upload: others

Post on 12-Jul-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTALLATION INSTRUCTION mUNIT POLE CLAMP...mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures

1 1/221 06-SXK 107 2862/1 Uen Rev A

© Ericsson AB 2013

Ericsson AB

SE-126 25 Stockholm, Sweden

Telephone +46 8 719 0000, Fax +46 8 18 40 85

www.ericsson.com

MB

INSTALLATION INSTRUCTION mUNIT POLE CLAMP

mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures of various size and shape.

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

Page 2: INSTALLATION INSTRUCTION mUNIT POLE CLAMP...mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures

32 1/221 06-SXK 107 2862/1 Uen Rev A

© Ericsson AB 2013

Ericsson AB

SE-126 25 Stockholm, Sweden

Telephone +46 8 719 0000, Fax +46 8 18 40 85

www.ericsson.com

CONTENTS

1. PRODUCT COVERED IN THIS INSTALLATION INSTRUCTION ............................................................ 2

2. PARTS INCLUDED ......................................................................................................................... 3

3. ASSEMBLY ................................................................................................................................... 4

4. OPTIONAL MOUNTING .................................................................................................................. 7

5. EXAMPLE OF PROFILES ................................................................................................................ 8

1. PRODUCT COVERED IN THISINSTALLATION INSTRUCTION

This installation instruction covers the mUnit Pole Clamp together with the mUnit Base Mount. The mUnit Pole Clamp is made of anodized aluminium and the fasteners are made of acid proof stainless steel. This instruction shows how the mount is assembled and mounted towards the mUnit.

RECOMMENDED TOOLS

Socket 15 mmSocket 17 mmU-Wrench 17 mmTorque wrenchSocket extension (might be needed for pan function mounting)

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

Page 3: INSTALLATION INSTRUCTION mUNIT POLE CLAMP...mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures

3 1/221 06-SXK 107 2862/1 Uen Rev A

© Ericsson AB 2013

Ericsson AB

SE-126 25 Stockholm, Sweden

Telephone +46 8 719 0000, Fax +46 8 18 40 85

www.ericsson.com

2

2. PARTS INCLUDED

ITEM QTY ART. NO DESCRIPTION 1 2 6121 CLAMP PROFILE, FRONT 2 2 6122 CLAMP PROFILE, BACK 3 4 1308 WASHER BRB M10 A44 4 2240 LARGE WASHER BRBS M10 A45 12 1395 NUT M6M M10 A46 4 6214 HEX HEAD BOLT M6S M10 x 185 A4

3

1

5

6

2

5

5

4

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

Page 4: INSTALLATION INSTRUCTION mUNIT POLE CLAMP...mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures

54 1/221 06-SXK 107 2862/1 Uen Rev A

© Ericsson AB 2013

Ericsson AB

SE-126 25 Stockholm, Sweden

Telephone +46 8 719 0000, Fax +46 8 18 40 85

www.ericsson.com

3. ASSEMBLY

Mount the mUnit Base Mount and the four M10 x 25 screws to the unit.

Please note that the mUnit Base Mount shall be mounted with the hinge towards the bottom of the unit.

Tighten the screws to torque 33 Nm (24 lb ft).

BEFORE ASSEMBLY

If omni antennas shall be mounted, the mUnit Omni Support must be mounted before the mUnit Pole Clamp and the mUnit Base Mount.

In this case please refer to the installation instruction for the mUnit Omni Support.

3.1 TILT FUNCTION MOUNTING ON TOWER LEG

2

1

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

Page 5: INSTALLATION INSTRUCTION mUNIT POLE CLAMP...mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures

5 1/221 06-SXK 107 2862/1 Uen Rev A

© Ericsson AB 2013

Ericsson AB

SE-126 25 Stockholm, Sweden

Telephone +46 8 719 0000, Fax +46 8 18 40 85

www.ericsson.com

4

Pre-assemble the mUnit Pole Clamp by assembling the M10 x 185 screws, the M10 washers and the M10 nuts.

Do not tighten the screws or nuts until step 5 and 8 of this assembly instruction.

Make sure you turn the back clamp in right posi-tion depending on the shape and size of the tower leg (see mounting examples on page 17).

3

4

Open up the mUnit Base Mount to maximum extent in order to get best accessibility.

Mount the mUnit Pole Clamps to the mUnit Base Mount.

The picture shows the mUnit Pole Clamp position for attaching the unit to a vertical structure. By turning the mUnit Pole Clamp 90 degrees the unit can be attached to a horizontal structure.

5

Tighten the M10 screws to torque 33 Nm (24 lb ft).

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

Page 6: INSTALLATION INSTRUCTION mUNIT POLE CLAMP...mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures

76 1/221 06-SXK 107 2862/1 Uen Rev A

© Ericsson AB 2013

Ericsson AB

SE-126 25 Stockholm, Sweden

Telephone +46 8 719 0000, Fax +46 8 18 40 85

www.ericsson.com

Open the mUnit Pole Clamps.

6

7

Close the mUnit Pole Clamps and mount the unit on the tower leg.

8

Tighten the M10 nuts to torque 33 Nm (24 lb ft).

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

Page 7: INSTALLATION INSTRUCTION mUNIT POLE CLAMP...mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures

7 1/221 06-SXK 107 2862/1 Uen Rev A

© Ericsson AB 2013

Ericsson AB

SE-126 25 Stockholm, Sweden

Telephone +46 8 719 0000, Fax +46 8 18 40 85

www.ericsson.com

6

1

Open up the mUnit Base Mount to maximum extent in order to get best accessibility.

Mount the mUnit Pole Clamps to the mUnit Base Mount.

The picture shows the mUnit Pole Clamp position for attaching the unit to a vertical structure.

By turning the mUnit Pole Clamp 90 degrees the unit can be attached to a horizontal structure.

2

Tighten the M10 screws to torque 33 Nm (24 lb ft).

Open the mUnit Pole Clamps.

3

4. OPTIONAL MOUNTING

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com

Page 8: INSTALLATION INSTRUCTION mUNIT POLE CLAMP...mUnit Pole Clamp is used together with mUnit Base Mount for installation of one mUnit on tower leg or other vertical or horizontal structures

MB8 1/221 06-SXK 107 2862/1 Uen Rev A

© Ericsson AB 2013

Ericsson AB

SE-126 25 Stockholm, Sweden

Telephone +46 8 719 0000, Fax +46 8 18 40 85

www.ericsson.com

35 x 35 to 60 x 60 mm 60 x 60 to 90 x 90 mm

Minimum opening 40 mm 100 mm opening

90˚ ANGLE PROFILES 35 x 35-90 x 90 mmFor 90˚ angle frame legs the back clamp profile should be turned with the protruding lips towards the frame member.

60˚ ANGLE PROFILES 40-100 mm For 60˚ angle frame legs turn the back profile with the protruding lips away from the frame member.

5. EXAMPLE OF PROFILES

ROUND TUBES Ø25-120 mmFor tubes Ø25-60 mm the back clamp profile should be turned with the protruding lips towards the tube. For tubes 60-120 mm the lips should be turned away from the tube.

Ø25-60 mm Ø60-120 mm

35 x 35 to 50 x 50 mm 50 x 50 to 90 x 90 mm

SQUARE PROFILES 35 x 35-90 x 90 mmFor square profiles 35 x 35 to 50 x 50 mm the back clamp profile should be turned with the protruding lips towards the frame member. For squares 50 x 50 to 90 x 90 mm the lips should be turned away from the frame member.

Max Ø120 mmMin Ø25 mm

Max 90 x 90 mmMin 35 x 35 mm

Max 90 x 90 mmMin 35 x 35 mm

All Enquiries:tel: +44 (0)1744 762 929email: [email protected]: www.etechcomponents.com