installation guide luna diamond plus - m...

30
V.08-2017 INSTALLATION GUIDE LUNA DIAMOND PLUS

Upload: others

Post on 17-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

V.08-2017

INSTALLATION GUIDELUNA DIAMOND PLUS

Page 2: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

1. General ................................................................................ 3 1.1 Transport and Installation 1.2 Types of fuel 1.2.1 Wood 1.2.2 Forbidden fuel 1.3 Starting the fire ................................................................. 42. Installation ............................................................................ 5 2.1 Actions upon installation 2.2 Positioning the fireplace 2.3 Insulation and finishing ...................................................... 6 2.4 Air supply for combustion ................................................. 7 2.5 Convecntion current ......................................................... 8 2.5.1 Natural convection 2.5.2 Convection generated by a fan (optional) 2.5.3 Hor air ducks 2.5.4 Design grids M-Design ............................................... 9-10 2.6 Fan ................................................................................... 11 2.6.1 Installation 2.6.2 Fan with dimmer 2.7 Flue ................................................................................. 11 2.7.1 Flue3. Regulate fireplace ................................................................. 124. General recommendations .................................................... 13 4.1 Maintenance 4.1.1 Cleaning the window .................................................. 145. Guarantee ............................................................................ 14 5.1 Terms and items covered .................................................. 14 5.2 Provisio ............................................................................ 14 5.2 Disclaimer ......................................................................... 146. Diamond technology ............................................................. 15 6.2 Standard frame ................................................................. 16 6.2.1 Standard frame “0” ...................................................... 16 6.2.2 4-sided frame .............................................................. 19 6.3 Finishing frame ................................................................. 217. Drawings .............................................................................. 22-30

The supplier takes no responsibility for any possible damage, poor workingappliances and accident as a result of incorrect installation

Page 3: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

1. General

1.1 Transport und Installation

• Transport the Luna in an upright position, or, in encumbering circumstances, at an angle of 45°.• The handles for transportation purposes have been attached inside the slots provided on the sides of the Luna (see Pic.1)• A set of rubber straps that can be turned and a set of fixed rubber straps are available as an option. This is to facilitate transport on-site and on the stairs.• Check to see that the lifting door functions properly before fitting the Luna.

1.2 Fuel

1.2.1 WoodThe quality of the wood is extremely important for the optimal functioning of the stove (output, clear glass, etc.). Good quality wood is wood that has been dried under an aerated shelter for at least 2 years (+ 18% moisture content). Damp wood gives off less heat and dirties the stove and the chimney less. You can also use briquettes (the effect is comparable with that of wood), and it is best to use them in combination with wood because burning only briquettes makes the temperature too high. Never fill the stove with wood because when the chimney draws too much, it can make the temperature too high. Damage as a result of excessive temperature is not under guarantee. 3 wooden logs are equal to 12 kW.

1.2.2 Forbidden fuel

The use of treated wood (painted, etc.) and all types of household waste, which can disperse hazardous gases, is FORBIDDEN and CANCELS OUT ANY CLAIM ON THE GUARANTEE. The use of fluid fuel (petrol, etc.) is also forbidden.

Pic.

LUNA DIAMOND - Installation guide - 3 -

Page 4: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

pic

1.3 Starting the fire

• Open the window (pic.).• Put a bed of tinder (paper or firelighters) with a little kindling (small twigs or pieces of wood) in the stove and light the tinder.• Leave the door slightly ajar (+ 3 cm) to get a turbo stream of air that will make the kindling catch fire.• After the kindling has caught fire and burns well, the logs may be placed on the fire. After the logs have caught fire, the window may be shut.

NOTE: When a fire is made for the first time, the paint will harden and that give off smoke and a smell, which starts after the fire has burned for about 10 minutes and lasts for about 15 minutes. See to it that there is ample ventilation in the room.

Side to open and close the windiw

Side to open the window for cleaning the glass

CAUTION :It is not necessary to overload the fireplace with wood. 1 kg dry wood gives a 4 kW power. Example : a fireplace with a 78% return gives a power for about 4kw x 78% = +/- 3 kW for 1 kg dry wood. If you want a power of +/-12 kW , it is just enough to put 4 kg wood in the fireplace. This is like two normal pieces of wood. Be carefull not to use palletwood (this gives an enormous heat) for continuous heating. This can lead to fire hazard. We are not responsible for the bad use of the fireplaces and any consequence for not following this guideline.

LUNA DIAMOND - Installation guide - 4 -

Page 5: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

A = min. 3,5 cmB = 14 cmC = 18 cm ( min.)

2. Installation

Before starting the installation, first check the fireplace

2.1 Actions to be taken upon installation

Your supplier is the specialist who chose to represent M-design in your area. For your own safety and satisfaction, we advise you to entrust him with the installation. The appliance has to be installed according to certain prescribed rules and local regulations. In the absence of the correct regulations in Belgium, the French regulations in respect of installation will be (D.T.U. 24.2.2) applicable.However, if you decide to carry out the work on your own, we advise you to do the following:

2.2 Positioning the fireplace:

Place the fireplace on a stable surface using the adjustable feet. Adjust the height of the fireplace by turning the bolt ( pic 1 )

Regulating the height of the appliance : This can be made in two ways. A regulation by 8 times 5 cm ( pic. 1 ) and a fine regulation by screw ( pic.2 ). The minimal height as from ground to the 4th side frame is 3,5 cm ( A min ). The minimal height “C min” will be 18 cm, measured as from the ground to 4th side frame. The maximal height as from the ground to the 4th side frame is 45 cm.

The stove may not be placed direct ont the floor to allow natural convection. The appertures for the air supply ( IN ) is situated underneath the appliances.

pic 1 pic 2

LUNA DIAMOND - Installation guide - 5 -

Page 6: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

45-75-105mm

2

B

H

10 mm

Min. 40 mm

Min. 5mm

2

2

10

X

Y

Min. 40 mm

XB

L

B2

2

Min. 5 mm 2

Min. 40 mm

Min. 40 mm

2.3 Insulation and finishing

Once installation is complete, the appliance can be fitted. Once you have checked everything, you can perform the final insulating and finishing operations.The built-in part of the furnace tends to be very warm. Please check that the furnace is not too narrowly fitted and that there is adequate space for the elimination of hot air. For insulation of the furnace, we advise you to use M Design insulating plates. You are advised against using any other insulation product. Inflammable materials as well may not be used for the finishing.

A very essential point when setting up the Luna Diamond is that the distance has to be respected inbetween fireplace and the finishing material for the mantlepiece such as marble, gipsum,...

metal scheet profile

mantlepiece

2mm space between frame andmantlepiece finishing

Installation with 4 sided frame

The masonry must be raised around the furnace. Because of the expansion of the furnace during combustion, an interstice of at least 5 mm must be provided on each side of the appli-ance. The masonry must not lean against the furnace. THE APPLIANCE MUST BE SET FREE . Please pay attention to leave approx. 2 mm inbetween the finishing frame and maconry

LUNA DIAMOND - Installation guide - 6 -

Page 7: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

2.4 Air supply fot combustion

Every form of combustion uses air. In the case of a thermally sealed room supplementary air supply is essential. One must at all times avoid creating under-pressure in the room. If a cooking hood ap-pe-ars to be absolutely essential in the adjoining room, sufficient air supply will have to be provided to avoid every form of under-pressure. You need an airlet with dia. 150mm coming from outisde, or a ventilated shelter. This air inlet you have to connect to the Luna Diamond

With the Luna Diamond, the fresh air for combustion is supplied directly from outside through a flexible (dia. 150mm) that is connected to one of the 4 entrances that are provided on the left, right or lower side of the fireplace. Use for this purpose one of five connection pieces.Thanks to this new system, the air that is required for combustion is completely separated from the convection air stream in the room . The appliance is always delivered with an open air inlet at the left side. If you want to change, you can remove the plate on the side you wish to connect en replace the plate on the side that was open before.

ø150Needed inlets for combustion air

Each Luna Diamond H, 550V, 850V 1 x ø150

Each Luna Diamond DH, DV, 1000V en 1150V 2 x ø150

Connection piece air inlet (dia.150mm)

Adaptor for connectionfresch air inlet on side of the appliance

Concevtion outlet

Convection inlet

Fresch air inlet from outside or ventilated shelter

Concevtion outlet

Convection inlet

LUNA DIAMOND - Installation guide - 7 -

Page 8: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

2.5 Convection current

2.5.1 Natural convection

It is compulsory to open 2 or 4 hot air vents at the top of the appliance. The entrance for the air supply convection are situated at the lower backside of the Luna Diamond and also through the opening that is provided for the fan. These have been constructed in such a way that no air can be blown out along here, not even with a fan. The stove is placed at least 20 mm above the floor (if placed on the floor) to allow for natural convection. A clearance of at least 4 dm3 , excluding the measurements of a dust filter, or at least 6 dm3 , including the measurements of a filter, must be provided for in the masonry. (Note: Remember to take the measurements of the clearance of the grids into account.)

2.5.2 Convection by means of a fan (optional)

It is compulsory to open at least 2 hot air vents. It is essential to separate the air supply ducts and the air vents correctly in the masonry. Some insulation material gets damaged in time, and it is essential to separate it from the ventilation air supply, otherwise one runs the risk that it is sucked in and spread in the house. It is therefore also advisable to use fixed insulation plates (Promatec, HT-platen or promatec). The fan may be mounted either on the out-side or on the inside, which even makes it possible to install a fan afterwards.

2.5.3 Hot air ducts

Thermally insulated ducts are essential for the optimal functioning of the ap-pliance (these cause ‘draught’ in the convection air current). By using the maxi-mum number of ducts (at least 2), the output is improved and the noise (that is caused by the displacement) is reduced. For the purposes of the installation of these ducts it is best to go vertically up-wards first for at least 1m and then to change direction, making a rather wide bend and avoid using a flue terminal grid with a small clearance because the speed loss that this causes reduces the efficiency of the hot air vents.

LUNA DIAMOND - Installation guide - 8 -

Page 9: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

2 dm²

4 dm²

DRL 2 (420 X 82)

488

484

82

2 2

484488

484

82

92 92

4411

570

82

269281465

2xØ

150

64

13

495 Ext.

82

489

822x

Ø15

0

13

64 82

115

44

70269

92 92281

499

479 Int. 473 Int.

499

2 2

488499

465

4813,5 3,5

489

5 5

489

Luna 550 Diamond (Plus)en

Luna 550 Gold +Hout / Bois

Luna 550 Diamond Gas/Gaz

488

484

82

2 2

484488

484

82

92 9244

115

70

82

269281465

2xØ

150

64

13

495 Ext.

82

489

822x

Ø15

0

13

64 82

115

44

70269

92 92281

499

479 Int. 473 Int.

499

2 2

488499

465

4813,5 3,5

489

5 5

489

488

484

82

2 2

484488

484

82

92 92

4411

5

70

82

269281465

2xØ

150

64

13

495 Ext.

82

489

822x

Ø15

0

13

64 82

115

44

70269

92 92281

499

479 Int. 473 Int.

499

2 2

488499

465

4813,5 3,5

489

5 5

489

488

484

82

2 2

484488

484

82

92 92

4411

5

70

82

269281465

2xØ

150

64

13

495 Ext.

82

489

822x

Ø15

0

13

64 82

115

44

70269

92 92281

499

479 Int. 473 Int.

499

2 2

488499

465

4813,5 3,5

489

5 5

489

DRL2 (489x82)voor / pour

DRL2 (484x82)voor / pour

Deze roosters kunnen ook gebruikt worden in plaats van de DRL 2 (420x82) - Ces grilles peuvent être utilisé à la place du DRL 2 (420x82)

2.5.4 Design Lüftungsgitter M-Design

EACH APPERTURE YOU MAKE, MUST BE CONNECTED WITH FLEXIBLE

Design Grid (Outlet)with 2 connections

Inlet grid convection air

Design Grid (Outlet) with 2connections

or

Inlet grid convection air

or

Design Grid (Outlet)with 4 connections

LUNA DIAMOND - Installation guide - 9 -

Page 10: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

488

484

82

2 2

484488

484

82

92 92

4411

5

70

82

269281465

2xØ

150

64

13

495 Ext.82

489

822x

Ø15

0

13

64 82

115

44

70269

92 92281

499

479 Int. 473 Int.

499

2 2

488499

465

4813,5 3,5

489

5 5

489

Luna 550 Diamond (Plus)en

Luna 550 Gold +Hout / Bois

Luna 550 Diamond Gas/Gaz

488

484

82

2 2

484488

484

82

92 92

4411

5

70

82

269281465

2xØ

150

64

13

495 Ext.82

489

822x

Ø15

0

13

64 82

115

44

70269

92 92281

499

479 Int. 473 Int.

499

2 2

488499

465

4813,5 3,5

489

5 5

489

488

484

82

2 2

484488

484

82

92 92

4411

5

70

82

269281465

2xØ

150

64

13

495 Ext.

82

489

822x

Ø15

0

13

64 82

115

44

70269

92 92281

499

479 Int. 473 Int.

499

2 2

488499

465

4813,5 3,5

489

5 5

489

488

484

82

2 2

484488

484

82

92 92

4411

5

70

82

269281465

2xØ

150

64

13

495 Ext.

82

489

822x

Ø15

0

13

64 82

115

44

70269

92 92281

499

479 Int. 473 Int.

499

2 2

488499

465

4813,5 3,5

489

5 5

489

DRL2 (489x82)voor / pour

DRL2 (484x82)voor / pour

Deze roosters kunnen ook gebruikt worden in plaats van de DRL 2 (420x82) - Ces grilles peuvent être utilisé à la place du DRL 2 (420x82)

Measurments installaion design grid with 2 connections in combination with decorative glass for 550V

IMPORTANT: After a long heating pause, we recommend removing the attached dust from your appliance. Clean hot air ducts, grilles, all surfaces and the panel (also inside) in and around your unit. Dust residues can be avoided Initial heating after the heating pause of the unit to odor nuisance and visible residues on the panel and the room ceilings.

Note: a circulation of hot air requires that no under-pressure be created in the room. A grid that is near the floor sees to it that cold air can be drawn in. Don’t connect those with a flexible. Air will find the way to get at the right place. Place all the fittings that you use at the same lengths and angles if possible, otherwise it is possible that some grids give off more heat than others and, seeing that a hot air pipe func-tions in a manner similar to a chimney, the one that is hot first has the most draught and therefore becomes hot even more quickly.

LUNA DIAMOND - Installation guide - 10 -

Page 11: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

2.6 Fan

2.6.1 Installation

• Remove the Chamotflex plates, the bottom plates and the opening to the fan. See pic.8.• Now slide the fan downwards to just under the stove.• Make the necessary electrical connections..

2.6.2 Fan with dimmer

• Leave the adjustment of the fan speed closed.• Fuse 1.5A (Take the knob off, unscrew the little plate, take it out if it is to be replaced.)• The adjustment screw for the minimum speed is under the knob.(M-design has developed a new induction dimmer which lets the fan run noiselessly and which may be bought as an option.)• The fan (optional) may be started after the fire has burned for 15 minu-tes.• Let the fan turn at the maximum speed for 12 hours the first time to let it run it

2.7 Flue

2.7.1 Flue

The construction of chimney must comply with strict conditions: All the Luna Diamond stoves have a standard flue opening of 300,250,200 or 180mm in diameter. Certain chimney configurations may require different standard diameters. In that case, look at table for the height of the flue and the possibility of reducing the diameter with the help of a reduction piece. Note : per 45° change of direction, one must keep to within 1m of this table.

The flue must be themally insulatedDo not connect more than one stove to chimney flue?

Luna Diamond (Plus) Ø300 Ø250 Ø200 Ø180 Ø150 Luna 700 H + > 4m > 7m 1 Ø150 Luna 850 H + ≥ 4m > 4m > 7m 1 Ø150 Luna 1000 H + ≥ 4m > 5m 1 Ø150 Luna 1150 H + ≥ 4m > 6m 1 Ø150 Luna 1300 H + ≥ 5m > 8m 1 Ø150 Luna 550 V + ≥ 4m > 5m > 7m 1 Ø150 Luna 850 V + ≥ 5m > 7m 1 Ø150 Luna 1000 V + ≥ 6m > 8m 2 Ø150 Luna 1150 V + ≥ 7m >9m 2 Ø150 Luna 850 DH + ≥ 5m ≥ 7m 2 Ø150 Luna 1150 DH + ≥ 6m ≥ 8m 2 Ø150 Luna 850 DV + ≥ 6m ≥ 8m 2 Ø150 Luna 1000 DV + ≥ 7m ≥ 9m 2 Ø150 Luna 800 DC > 6m 1 Ø150 Luna 1000 DC ≥ 5m > 9m 1 Ø150 Luna 900 CL/CR + ≥ 5m > 7m 1 Ø150 Luna 1100 CL/CR ≥ 6m > 9m 1 Ø150 Luna 750 RD ≥ 5m 1 Ø180 Luna 1000 RD ≥ 6m 1 Ø180

Table: MINIMUM HEIGHT OF THE FLUE IN TERMS OF ITS REDUCTION.

LUNA DIAMOND - Installation guide - 11 -

Page 12: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

0 --> 1/2 1/2 -->1

0

1

0 1

Pos. 0(MIN.)

Pos. 1(MAX.)

spoiler

Primery air open

3. Operation & control of combustion air

The air is fed to the fire under the spoiler over the entire width.It is therefore important to regularly remove the ash under the spoiler.

The control of the combustion air supply is controlled manually. Use the cold hand to move the slider to the right to increase airflow and slide to the left to decrease airflow. With an open door, the regu-lation will have no effect on the fire.

Position 0 -> 1/2 : the primary air is closed and the fire is only provided by the secondary air

Position 1/2 -> 1 : the primary air is open and the fire is additionally provided by the secondary air

Primary air closed

Sekundärluft

Secondary air

primary air

LUNA DIAMOND - Installation guide - 12 -

Page 13: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

4. General recommendations

The appliance must be connected to the flue pipe and tested before the material is cemented in. In order to ensure that the appliance functions optimally, one must insulate the hot air ducts completely, comply with the minimum of the diameter measurements for the hot air ducts and hot air vents and the chimney must be adjusted. Do not put any inflammable materials in the immediate vicinity of the stove. Note: If you leave the door open, little burning pieces of wood may be projected onto the floor. Insulating materials: it is preferable to use “high temperature” materials. It is strongly advisable to position the chimney and to connect the stove in such a way that no humi-dity or water can enter the stove. Humidity and water are the greatest enemies of the Chamot-flex in the appliance because it can swell and burst after the fire has been lit.

4.1 Maintenance

• Besides regularly cleaning the window, you must have your chimney swept at least once a year

• A fire brick (Chamotte) can still work perfectly, even if it is cracked, but if pieces are missing the brick must be replaced to effectively protect the combustion chamber.

• Remove regularly excessive ash. Note: never remove the entire ash, because a wood fire is best burned on a bed of its own ash.

• For regular use, the high-temperature mechanism should be oiled with a temperature-resistant silicone oil. (Do not use any other lubricant). This silicone oil, based on Teflon, is available from the supplier of M-design. At repeated high temperatures, the mechanism could dry out and block the disc.

Ash pan

LUNA DIAMOND - Installation guide - 13 -

Page 14: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

8

4.1.1 Reinigung der Suchtscheibe

• Move the window all the way down.• Under the top bar, there are two or more hooks that will take you with your finger upto press. The window will now open at an angle of 45 °. To close, press the window back until it snaps back into the hooks.• Now you have the possibility to move the viewing window up and down and clean it.• For cleaning the window, we recommend “Bio-Clean” from M-design. ThisCleaning agent does not attack the surface and is available from your supplier.

5. Guarantee

5.1 Terms and items covered• 8 years’ guarantee on the general structure.• 2 years’ guarantee on the parts and on the baffle plate• 1 year’s guarantee on the fans and the speed variator.• No guarantee on glass, seals or Chamotflex plates5.2 ProvisioThis contract ceases to be valid if the instructions and guidelines of these operating instructions were not followed. Indemnification during the guarantee period will take place only through the supplier’s mediation upon presentation of the invoice of purchase. Parts will be delivered only in replacement of defect parts.5.3 DisclaimerDamage, loss and malfunctions linked to:• Incorrect installation of incorrect connection.• Chimney draught that has not been adjusted.• Transport and installation.• Incorrect usage.• Insufficient maintenance.• Unsuitable, hazardous and damp fuel.• Every internal adjustment to or reconstruction of the stove.• Burning at extremely high temperature, more than 12 kw.• Costs for packaging and transport.• All costs not pre-arranged with M-design.• Costs linked to the misuse and/or abuse of the appliance.

Tilt the window (see cleaning).Lift these upwards until you get the slots(See picture).At the top left, read the serial number.

Hooks

LUNA DIAMOND - Installation guide - 14 -

Page 15: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

6. Diamond technology

Automatic window with remote control (accessory):In order to remove the system completely from the device in the installed state, the following must be observed.Keep the distance between the oven and the panel at least 25cm (for horizontal units) and 35cm (for vertical models).

LUNA DIAMOND - Installation guide - 15 -

Page 16: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

B

H35

14

8

19-20 mm

B ext. / B int. H ext. / H int.550V Diamond 495 / 479 908 / 892

550Vs Diamond 495 / 479 668 / 652

700H Diamond 645 / 629 458 / 442

700Hs Diamond 645 / 629 358 / 342

850H Diamond 795 / 779 458 / 442

850V Diamond 795 / 779 668 / 652

1000H Diamond 945 / 929 458 / 442

1000V Diamond 945 / 929 708 / 692

1150H Diamond 1095 / 1079 458 / 442

1150V Diamond 1095 / 1079 708 / 692

1300H Diamond 1245 / 1229 458 / 442

850DH Diamond 795 / 779 458 / 442

850DV Diamond 795 / 779 668 / 652

1000DV Diamond 945 / 92 708 / 692

1150DH Diamond 1095 / 1079 458 / 442

5-6 mm

6.2 Standard frameThe device is supplied with the mounting frame “0” as standard. There are 3 further versions of the mounting frame (page 21). Please specify and order the frame with the device.

6.2.1 Standard frame “0”

LUNA DIAMOND - Installation guide - 16 -

Page 17: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

A

A2

1

x

X’

4

5

21

X’ X

5

3

6

6

Y

Z

Removing and adjusting the standard frame “0”

To move the side part (6) of the frame remove, the screw (3)and loosely loosen the screws (1 & 2).Now press the frame slightly towards (Y)And then take it in the direction (Z).

LUNA DIAMOND - Installation guide - 17 -

Page 18: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

*

A

B

B

C

C

12

3

*

*

B int. H in

t.

The standard mounting frame “0” is used when you are using you own panel at the sides (mantel-piece)Please leave an expansion joint of 1 mm (*) between the frame and the fairing.

B Int. (See the table on page 19)

The mounting frame can be easily adapted to the panel. By loosening the screws 1, 2 and 3, the mounting frame can be adjusted in the directions A, B and C. So you can get it perfect aligned. Leave 1mm * space between the mounting frame and the panel.

LUNA DIAMOND - Installation guide - 18 -

Page 19: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

45-75-105mm

B

H

45-75-105mm

B ext. / B int. H ext. / H int.550V Diamond 495 / 479 908 / 892

550Vs Diamond 495 / 479 668 / 652

700H Diamond 645 / 629 458 / 442

700Hs Diamond 645 / 629 358 / 342

850H Diamond 795 / 779 458 / 442

850V Diamond 795 / 779 668 / 652

1000H Diamond 945 / 929 458 / 442

1000V Diamond 945 / 929 708 / 692

1150H Diamond 1095 / 1079 458 / 442

1150V Diamond 1095 / 1079 708 / 692

1300H Diamond 1245 / 1229 458 / 442

850DH Diamond 795 / 779 458 / 442

850DV Diamond 795 / 779 668 / 652

1000DV Diamond 945 / 92 708 / 692

1150DH Diamond 1095 / 1079 458 / 442

6.2.2 4-sided frame

LUNA DIAMOND - Installation guide - 19 -

Page 20: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

21

3

Z

Z

Z

Z

X

XY

Y

Y

Y

Detail A

Detail B

1 à 2mm

Detail A

Detail B

2mm

BH

B ext+2+2 mm H e

xt +

2+2m

m

The mounting frames are also used when the panel is around the frame. Leave the frame 2 mm of air (detail B) around the frame and let it protrude 1-2 mm from the panel.

Detail A : B ext. + 2 + 2mm and H ext. + 2 + 2mm (see table)

All sizes and depths of the mounting frames can be adjusted in the same way.

LUNA DIAMOND - Installation guide - 20 -

Page 21: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

5mm

24

20

A

B

4

D

C

25-40-70mm

10mm

4mm

25-40-70mm

Model A (mm) B (mm) C (mm) D (mm)

550V Diamond 477 890 505 918

550Vs Diamond 477 650 505 678

700H Diamond 627 440 655 468

700Hs Diamond 627 340 655 368

850H Diamond 777 440 805 468

850V Diamond 777 650 805 678

1000H Diamond 927 440 955 468

1000V Diamond 927 690 955 718

1150H Diamond 1077 440 1105 468

1150V Diamond 1077 690 1105 718

1300H Diamond 1227 440 1255 468

850DH Diamond 777 440 805 468

850DV Diamond 777 650 805 678

1000DV Diamond 927 690 955 718

1150DH Diamond 1077 440 1105 468

6.3 finishing frame

In order to mount the frame / outer frame, 5 mm air must be left to the trim around the 4-side frame. The glare frame consists of a circumferential T-profile.

Size of opening: B + 2 x 5mm and H+ 2 x 5mm. (siehe Table)

mantle

finishing frame

4-sided frame

4-sided frame

LUNA DIAMOND - Installation guide - 21 -

Page 22: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

141

458

EXT.

567

629INT.

442

INT.

MIN

35MA

X 45

095

590

210

136

166

368

534

1166

210

142

96

242

800

300

250

9134

6

200

230

739 31

120 560 120

187

115

150

84

400

645EXT.

ø150

ø150

ø200 int.

ø150

20

211

5

141

458

EXT.

567

779INT.

442

INT.

MIN

35MA

X 45

095

590

210

136

166

368

534

1166 210

142

96

242

950

300

250

9134

6

200

230

889 31

135 680 135

187

11515

0

84

480

795EXT.

ø150

ø150

ø250 int.

ø150

20

211

5

700H Diamond

850H Diamond

141

458

EXT.

567

629INT.

442

INT.

MIN

35MA

X 45

095

590

210

136

166

368

534

1166

210

142

96

242

800

300

250

9134

6

200

230

739 31

120 560 120

187

115

150

84

400

645EXT.

ø150

ø150

ø200 int.

ø150

20

211

5

141

458

EXT.

567

779INT.

442

INT.

MIN

35MA

X 45

095

590

210

136

166

368

534

1166 210

142

96

242

950

300

250

9134

6

200

230

889 31

135 680 135

187

11515

0

84

480

795EXT.

ø150

ø150

ø250 int.

ø150

20

211

5

700H Diamond

850H Diamond

7. Technische Zeichnungen

LUNA DIAMOND - Installation guide - 22 -

Page 23: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

1000H Diamond

1150H Diamond

141

458

EXT.

567

929INT.

442

INT.

MIN

35MA

X 45

095

590

210

136

166

368

534

1166 210

142

96

242

1100

300

250

9134

6

200

2301039 31

140 820 140

187

11515

0

84

520

945EXT.

ø150

ø250 int.

ø150

ø150

20mm

211

5

ø 250 int.

Ø150

141

458

EXT.

567

1079INT.

442

INT.

M

IN 3

5MA

X 45

095

590

210

136

ø150

166

368

534

1166 210

142

96

242

1250

250

9134

6

200

230

1189 31

215 820 215

187

115

150

84

520

1095EXT.

Ø150

20

300

211

5

LUNA DIAMOND - Installation guide - 23 -

Page 24: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

1300H Diamond

550V Diamond

141

458

EXT.

567

1229INT.

442

INT.

M

IN 3

5MA

X 45

095

590

210

136

166

368

534

1166

210

142

96

242

1400

300

250

9134

6

200

230

1339 31

280 840 280

187

115

150

84

540

1245EXT.

ø150

20

ø150

ø250 int.

ø150

211

5

141

908

EXT.

715

479INT.

892

INT.

MIN

35MA

X 45

014

0590

210

130

166

368

534

1764

210

142

96

242

650

359

220

9134

6

589 31

108 108

187

495EXT.

ø150

ø250

ø150

ø150

20

434

250

154

200

5

LUNA DIAMOND - Installation guide - 24 -

Page 25: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

850V Diamond

1000V Diamond

141

668

EXT.

817

779INT.

652

INT.

M

IN 3

5MA

X 45

0116

590

210

136

166

368

534

1626 210

142

96

242

950

300

250

9134

6

200

230889 31

135 680 135

187

11515

0

84

480

795EXT.

ø150

ø250

ø150

ø150

20

5

461

141

708

EXT.

817

929INT.

692

INT.

M

IN 3

5MA

X 45

010

2590

210

136

166

368

534

1666 210

142

96

242

1100

300

250

9134

6

200

230

140 820 140

187

11515

0

84

520

945EXT.

ø150

ø250

ø150

ø150

20

461

5

LUNA DIAMOND - Installation guide - 25 -

Page 26: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

1150V Diamond

850DH Diamond

141

708

EXT.

817

1079INT.

692

INT.

M

IN 3

5MA

X 45

010

2590

210

136

166

368

534

1666 210

142

96

242

1250

300

250

9134

6

200

230

1189 31

215 820 215

187

11515

0

84

520

1095EXT.

ø150

ø250 int.

ø150

ø150

20

5

461

458

EXT.

458

EXT.

141

567

141

567

20

5

20

5

391

90

121 142

96

442

INT.

779INT.

1166

950

MIN.

45MA

X. 45

0

ø300 int.

723 ø150

520 100100

441,5

281,5

530

889

170

ø150

ø150

30,530,5

610

90

748

748

160

115115

LUNA DIAMOND - Installation guide - 26 -

Page 27: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

1150DH Diamond

850DV Diamond45

8EX

T.

458

EXT.

141

567

141

567

20

5

20

5

391

90

121 142

96

442

INT.

1079INT.

1166

1250

MIN.

45

MAX.

450

ø300 int.

723

ø150

280

361,5

361,5

530

1189

170

ø150

ø150

30,530,5

910

90

748

748

220 280 220

668

EXT.

668

EXT.

141

817

141

567

20

5

20

5

391

90

371

142

96

652

INT.

779INT.

1626

950

MIN.

45

MAX.

450

ø300 int.

723 ø150

520 100100

441,5

281,5

530

889

170

ø150

ø150

30,530,5

610

90

748

748

160

115115

LUNA DIAMOND - Installation guide - 27 -

Page 28: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

1000DV Diamond

800DC Diamond

692

EXT.

692

EXT.

141

817

141

567

20

5

20

5

391

90

371

142

96

692

INT.

929INT.

1666

1100

MIN.

45MA

X. 45

0

ø300 int.

723 ø150

560 120120

441,5

281,5

530

1039

170

ø150

ø150

30,530,5

76090

748

748

160

150150

MAX

6015

54

775

2613

12

132

573

848

402

INT.5

65

ø 150

ø 150

508

271

650

300

550

435 165

600

211

243

250

230690

24

MIN

10

600

186

145 145 ø200

402873

236

EXT.5

73

100

ø150

873

402

LUNA DIAMOND - Installation guide - 28 -

Page 29: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

1000DC Diamond

900CL/CR Diamond

MAX

60

1554

975

2613

12

132

573

848

402

INT.5

65

ø 150

508

271

850

300

550

435 165

600

211

243

250

230 890

24

MIN

10

600

211

ø150

230 230 ø 250

236 1073

100

402

573

EXT.ø 15

0

1073

402

1357

MAX

6012

1226

508

132

474

751

INT.4

66

450

300

MIN

10

274

435 165

600

24

933

800

ø150

848

211

211

600

220 220ø 250

ø150

250

230

928

474

EXT.

397

100

397

238

ø150

928

397

LUNA DIAMOND - Installation guide - 29 -

Page 30: INSTALLATION GUIDE LUNA DIAMOND PLUS - M Designm-design.be/wp-content/uploads/2018/10/Luna_Diamond_Wood... · 2019-08-28 · Each Luna Diamond H, 550V, 850V 1 x ø150 Each Luna Diamond

1000CL/CR Diamond

750RD Diamond

1357

MAX

6012

1226

508

132

474

751

INT.4

66

450

300

MIN

10

274

435 165

600

24

1133

1000

ø150

1048

211

211

600

220 220ø 250

ø150

250

230

1128

474

EXT.

397

100397

238

ø150

1128

397

EXT.

453

673

195

INT.

445

63

GLASS 750INT. 881

931.5

1111.5

705

256Ø250

EXT. 885

1321

MIN.

41MA

X. 95

72.5

GLASS 500

72.5

GLAS

S 45

0590

215

1106

Ø180508582

4 697 4

705EXT. 885

EXT.

453

4

44

560582

1000RD Diamond

EXT.

453

673

195

INT.

445

63

GLASS 1000INT. 1131

1181.5

1344.5

705

406Ø250

EXT. 1135

1321

MIN.

41MA

X. 95

72.5

GLASS 500

72.5

GLAS

S 45

0

590

215

1106

Ø180508582

4 697 4

4

4

560582

EXT.

453

705

EXT. 1135

4

LUNA DIAMOND - Installation guide - 30 -