inspection date: 8/26/2011 rc: 43 bin: 1070910 bridge ratings · 2011. 8. 26. · inspection date:...

29
Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589 RC: 43 BIN: 1070910 Bridge Ratings Inspection Date: 8/26/2011 Inspection Agency: 10 - NYSDOT Type of Inspection: 1 - BIENNIAL GTMS: B02 -- Unpainted Steel Continuous - Stringer/Multi-Beam or Girder POSTINGS: See Gen Rec Page 1 for Postings at time of inspection. Further Investigation Needed: No State Highway Number: 000000 Milepoint: 0 AADT/Yr: 14954 / 2003 Orientation: 3 - East Political Unit: 0092 - Town of BRIGHTON Year Built: 1981 Total Spans: 2 Ramp Bridge Attached To Span: NA BIN: NA General Recommendation: 5 Computed Condition Rating: 4.972 Abutment Ratings: Beg Abut End Abut Joint with Deck 7 7 Bearings, Bolts, Pads 6 7 Seats and Pedestals 4 5 Backwall 5 5 Stem (Breastwall) 4 4 Erosion or Scour 6 6 Footings 9 9 Piles 9 8 Recommendation 5 5 Wingwall Ratings: Beg Abut End Abut Walls 5 5 Footings 9 9 Erosion or Scour 6 6 Piles 9 8 Channel Ratings: Channel Stream Alignment 8 Erosion and Scour 8 Waterway Opening 8 Bank Protection 8 Approach Ratings: Approaches Drainage 5 Embankment 6 Settlement 6 Erosion 6 Pavement 5 Guide Railing 4 Number of Flags Issued: RED: 0 Yellow: 0 Safety: 0 Vulnerability Reviews Recommended: 1=Yes, 2=No, 3=NA, X=NotActive Hydraulic: 3 Overload: X Steel: 1 Collision: 2 Concrete: X Seismic: X Inspector's Signature: CheckValue: 1,769,216,589 Date: 8/26/2011 Brian P. Till,PE () (Inspector ID:4000045) Signed copy of this inspection report is available in the appropriate NYSDOT Regional Office Reviewed By: Date: 9/15/2011 A P. Smith,PE () (QC ID:4000048) Signed copy of this inspection report is available in the appropriate NYSDOT Regional Office

Upload: others

Post on 06-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Bridge Ratings

Inspection Date: 8/26/2011

Inspection Agency: 10 - NYSDOT Type of Inspection: 1 - BIENNIALGTMS: B02 -- Unpainted Steel Continuous - Stringer/Multi-Beam or GirderPOSTINGS: See Gen Rec Page 1 for Postings at time of inspection.Further Investigation Needed: NoState Highway Number: 000000 Milepoint: 0 AADT/Yr: 14954 / 2003Orientation: 3 - East Political Unit: 0092 - Town of BRIGHTON Year Built: 1981Total Spans: 2 Ramp Bridge Attached To Span: NA BIN: NAGeneral Recommendation: 5 Computed Condition Rating: 4.972

Abutment Ratings: Beg Abut End Abut Joint with Deck 7 7 Bearings, Bolts, Pads 6 7 Seats and Pedestals 4 5 Backwall 5 5 Stem (Breastwall) 4 4 Erosion or Scour 6 6 Footings 9 9 Piles 9 8 Recommendation 5 5

Wingwall Ratings: Beg Abut End Abut Walls 5 5 Footings 9 9 Erosion or Scour 6 6 Piles 9 8

Channel Ratings: Channel Stream Alignment 8 Erosion and Scour 8 Waterway Opening 8 Bank Protection 8

Approach Ratings: Approaches Drainage 5 Embankment 6 Settlement 6 Erosion 6 Pavement 5 Guide Railing 4

Number of Flags Issued: RED: 0 Yellow: 0 Safety: 0

Vulnerability Reviews Recommended: 1=Yes, 2=No, 3=NA, X=NotActive Hydraulic: 3 Overload: X Steel: 1 Collision: 2 Concrete: X Seismic: X

Inspector's Signature: CheckValue: 1,769,216,589 Date: 8/26/2011

Brian P. Till,PE () (Inspector ID:4000045)

Signed copy of this inspection report is available

in the appropriate NYSDOT Regional Office

Reviewed By: Date: 9/15/2011

A P. Smith,PE () (QC ID:4000048)

Signed copy of this inspection report is available

in the appropriate NYSDOT Regional Office

Page 2: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

RC: 43 BIN: 1070910 Span Ratings

Inspection Date: 8/26/2011

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

Deck Element Ratings: 001 002 Wearing Surface 6 6 Curbs 8 8 Sidewalks, Fascias 5 5 Railings, Parapets 5 5 Scuppers 8 8 Gratings 8 8 Median 8 8 Mono Deck Surface 6 6

Superstructure Ratings: 001 002 Structural Deck 5 5 Primary Members 5 5 Secondary Members 5 5 Paint 4 4 Joints 8 8 Recommendation 5 5

Pier Ratings: 001 002 Bearings, Bolts, Pads 5 8 Pedestals 6 8 Top of Cap or Beam 6 8 Stem Solid Pier 8 8 Cap Beam 5 8 Pier Columns 6 8 Footings 9 8 Erosion or Scour 6 8 Piles 8 8 Recommendation 5 8

Utility Ratings: 001 002 Lighting 8 8 Sign Structure 8 8 Utilities and Support 8 8

Field Notes:Field Date Arrival Departure Temp (C) Temp (F) Weather Conditions 5/26/2011 9:00:00 AM 2:30:00 PM 70 sunny8/26/2011 8:00:00 AM 8:15:00 AM 70 sunny

Page 3: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

RC: 43 BIN: 1070910 Inspection Notes

Inspection Date: 8/26/2011

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

Note ID: 4C1110709100000 Beg Abut -- Abutment: Joint with Deck -- Rated 7, Was 3 Beg Abut -- Abutment: Bearings, Bolts, Pads -- Rated 6, Was 3 End Abut -- Abutment: Joint with Deck -- Rated 7, Was 4 End Abut -- Abutment: Bearings, Bolts, Pads -- Rated 7, Was 4 Referenced Photos: "1", "2", "3", "4" New abutment joints have been installed under contract D261062, consisting of elastomeric concrete headers with foam seals. Also, new elastomeric bearings have been installed at both abutments. All begin bearings are slightly expanded at today's 70 degree F temperatures. End bearings are slightly expanded or vertical. The end left corner of Begin bearing 1 elastomer is raised off its pedestal about 1/8" such that the begin side is compressed 1/4" more than the end at left. Begin bearing 1 rates 6 while all others rate 7.

Note ID: 4C1110709100001 Beg Abut -- Abutment: Seats and Pedestals -- Rated 4, Was 4 Referenced Photos: "3" Begin abutment pedestal 2 is spalled 6" by 4" by 2" deep with a few cracks around this spall near top end corner and rates 4. All other pedestals rate higher. The bridge seat is spalled up to 4" deep in bay 1 at end corner with rusted rebar exposed. The remainder of the bridge seat is delaminated along 60% of its length with efflorescence and exudations.

Note ID: 4C1110709100002 Beg Abut -- Abutment: Stem (Breastwall) -- Rated 4, Was 4 Referenced Photos: "5" The begin abutment stem appears cracked and delaminated over 35%+/- of its area with some efflorescence, exudations and rust staining, especially at left. There is spalling at various locations totalling 15 sq ft+/-.

Note ID: 4C1110709100004 Approaches: Guide Railing -- Rated 4, Was 4 Referenced Photos: "7" The begin left concrete jersey barrier appears cracked, delaminated and spalled to rusted rebar. This railing rates 4 and all other approach railing would rate a 5 or higher.

Note ID: 4C1110709100005 Span 001 -- Superstructure: Paint -- Rated 4, Was 4 Span 002 -- Superstructure: Paint -- Rated 4, Was 4 Referenced Photos: "8" Rusting A588 steel has flakes up to dime-size in spots throughout, especially under abutment joints and over roadways. Areas nearest main girder lower flanges are most severely affected. About a third of the steel area is so affected; remaining "paint" appears mostly intact.

Page 4: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

RC: 43 BIN: 1070910 Inspection Notes

Inspection Date: 8/26/2011

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

Note ID: 4C1110709100005 - continued

Note ID: 4C1110709100003 End Abut -- Abutment: Stem (Breastwall) -- Rated 4, Was 4 Referenced Photos: "6" The end abutment stem appears cracked and delaminated with some efflorescence and rust staining over 25%+/- of its area, especially at right. There is spalling at various locations totalling 5 sq ft+/-. The stem rates a high 4. �

Page 5: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Inspection Photos in Photo Number Order

Inspection Date: 8/26/2011

Begin abutment joint (typ.)

Photo Number: 1 Photo Filename: 115531.JPG

Begin abutemnt bearing 1 at left

Photo Number: 2 Photo Filename: 115532.JPG

Page 6: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Inspection Photos in Photo Number Order

Inspection Date: 8/26/2011

Begin abutment bearing 2 and ped 2

Photo Number: 3 Photo Filename: 115533.JPG

End abutment bearing 1 at right

Photo Number: 4 Photo Filename: 115528.JPG

Page 7: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Inspection Photos in Photo Number Order

Inspection Date: 8/26/2011

Begin stem at left

Photo Number: 5 Photo Filename: 115534.JPG

End stem at right

Photo Number: 6 Photo Filename: 115527.JPG

Page 8: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Inspection Photos in Photo Number Order

Inspection Date: 8/26/2011

Begin left approach guiderail

Photo Number: 7 Photo Filename: 115530.JPG

Span 2, girder 2 at right (paint typ.)

Photo Number: 8 Photo Filename: 115529.JPG

Page 9: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Inspection Sketches in Sketch SysID Order

Inspection Date: 8/26/2011

Sketch ID: 4C1110709100000 Sketch Filename: PhLoc.11 General Sketch for Bridge Referenced Photos: Photo locations

Page 10: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Inspection Sketches in Sketch SysID Order

Inspection Date: 8/26/2011

Sketch ID: 4C1110709100001 Sketch Filename: VC.11 General Sketch for Bridge Referenced Photos: Vertical clearances

Page 11: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Inspection Sketches in Sketch SysID Order

Inspection Date: 8/26/2011

Sketch ID: 4C1110709100002 Sketch Filename: SDVA_REV.11 General Sketch for Bridge Referenced Photos: Steel details vulnerability form

Page 12: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

RC: 43 BIN: 1070910 Gen. Rec., Postings, Federal Ratings, etc.

Inspection Date: 8/26/2011

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

Overall Condition: GENERAL RECOMMENDATION: 5 Computed Condition Rating: 4.972

Problems Requiring Action: NO Further Investigation Needed NO Flags Issued

POSTINGS: Inspector Confirmed existing Posting data as correct. Posted Vertical Clearance ON the bridge is: No Posting Posted Vertical Clearance UNDER the bridge is: No Posting No Load Restriction is posted on this bridge

Overloads Observed: NO Overload Vehicles were observed on this bridge

FEDERAL RATINGS: NBI Deck Condition: 7 NBI Superstruct Condition: 7 NBI Substruct Condition: 5 NBI Channel Condition: N NBI Culvert Condition: N

Diving Inspection Needs: Diving Inspection Required? No Date of Last Diving Inspection: No Date

Inventory Problems: Inventory Problems Exist? No

Miscellaneous: Time Required to Inspect Bridge: 10 Hours Lane Closure Needs: By Contract for 5.5 Hours No Railroad Flagging Required No Pedestrian Fence No Snow Fence The BIN Plate is in OK condition

Page 13: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

RC: 43 BIN: 1070910 Gen. Rec., Postings, Federal Ratings, etc.

Inspection Date: 8/26/2011

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

Special Emphasis Inspection Required: Non-Redundant/Fracture Critical Members - No Pin and Hangers - No Fatigue-Prone Welds - Yes Non-Categorized Fatigue-Prone Details - No Other (Specified in Text) - No

Special Emphasis Details: Lower flange gusset plate welds, both spans; all inspected hands-on, no cracks detected.

General Notes To the Next Inspector: BIN plate on begin abutment stem at left

Improvements Observed: New abutment joints have been installed under contract D261062, consisting of elastomeric concrete headers with foam seals. Also, new elastomeric bearings have been installed at both abutments.

Page 14: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Review Progress and Personnel Present at Inspection

Inspection Date: 8/26/2011

Inspection Submission Status: Submitted to QC Engineer on: 9/14/2011 QC Submission Number: C5412801 QC Review Completed: 9/15/2011 QC Engineer: A P. Smith Submitted to Liaison Engineer on: 9/22/2011 Liaison Submission Number: 54113 Liaison Review Completed: 11/9/2011 Liaison Engineer: David P. Van Zanten Submitted for BIIS Processing on: 11/9/2011 BIIS Submission Number: .kp1 Current Status: Keypunched, Sent to BIIS Check Value: 1,769,216,589

Personnel Present During Inspection: Brian P. Till - Team Leader Douglas J. Warriner - Assistant Team Leader Frank Disalvo - M&PT Garfield Jones - M&PT Kevin Smith - M&PT

Page 15: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Inspection Access Requirements

Inspection Date: 8/26/2011

Equipment Required for Inspection No Access Requirement Changes Noted During This Inspection. This Listing is from the Inventory Database. ACCESS CATEGORIES FOR ENTIRE BRIDGE Required: Walking, Small Lift, Lane Closure, Shadow Vehicle ACCESS CATEGORIES FOR SPAN 1 Required: Walking, Small Lift, Lane Closure, Shadow Vehicle ACCESS CATEGORIES FOR SPAN 2 Required: Walking, Small Lift, Lane Closure, Shadow Vehicle

Page 16: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146 CheckValue: 1,769,216,589

RC: 43 BIN: 1070910 Culvert Measurements

Inspection Date: 8/26/2011

Culvert Measurements NO CULVERT DATA FOR BIN 1070910

Page 17: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

1070910_LOCATION_MAP.JPG

Page 18: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

1070910_QUAD_MAP.JPG

Page 19: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

AbutmentBegin.jpg

Page 20: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

AbutmentEnd.jpg

Page 21: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

AcrossDeckTyp.jpg

Page 22: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

ApproachBegin.jpg

Page 23: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

ApproachEnd.jpg

Page 24: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

ElevationRight.jpg

Page 25: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

framingspan1.jpg

Page 26: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

FramingSpan2.jpg

Page 27: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

I_390Left.jpg

Page 28: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

I_390Right.jpg

Page 29: Inspection Date: 8/26/2011 RC: 43 BIN: 1070910 Bridge Ratings · 2011. 8. 26. · Inspection Date: 8/26/2011 Equipment Required for Inspection No Access Requirement Changes Noted

Carried: EW CONNECTION Crossed: 390I 390I43031146

RC: 43 BIN: 1070910 Standard Photos

Pier01.jpg