Page 1: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

Inspection ReportJames Doe

Property Address:1818 S Halcyon Drive

Chicago IL

1818 S Halcyon Drive

Domicile Consulting

Dan Cullen 450.000570 Expires Nov. 20182545 W Diversey Ave Suite 206

Chicago IL 60647312-488-1461

DoeDomicile Consulting

Page 1 of 321818 S Halcyon Drive

Page 2: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

I. Domicile Consulting ReportThis inspection is being conducted in accordance with the State of Illinois Home Inspector Licensing Act. No pest control, lead paint, asbestos, mold,or other types of testing are being performed. This is a visual inspection of readily accessible systems and components of the building/s.Some items or areas may not be inspected if they are blocked by furniture or stored items. The inspector makes no guarantees regarding any of thebuilding's systems or components. The inspection is performed in good faith and is a 'snapshot in time'; it is does NOT constitute aprediction that the buildings systems and components will perform adequately in the future. Only non-invasive processes are used in thecourse of the inspection. Seasonal changes such as wind-driven rain, ice, and humidity may bring some defects to light that were not noted duringyour property inspection. Basements and attics that were dry at the time of the inspection can be damp or leak in later weeks or months. Ifyou discover any adverse conditions in the Property after your Domicile Consulting inspection, please call us immediately for a re-inspection and free consultation. Your inspection fee will be refunded without question if you are unhappy with the inspection for any reason,provided the buyer/client signs a 'hold harmless' agreement when accepting the refunded fee. No guarantees or warranties are provided inconnection with this inspection. Any disputes that cannot be resolved by the inspector and the client will be submitted jointly to the AmericanArbitration Association for a decision.

Styles & Materials

ROOF COVERINGS:Composition (Asphalt or Fiberglass)

ShinglesModified Bitumen

ROOF VIEWED:From a Raised Vantage Point Such as a

Lower RoofRoof Was Walked

GAS SHUT-OFF LOCATION:Garage

POTABLE WATER SOURCE:Public

WATER SERVICE PIPING MATERIAL:CopperMain Water Shut-Off Location : Lower-

Level Mechanical Closet

WATER SUPPLY PIPING MATERIAL:CopperNot Fully VisibleWater Pressure and Flow : Appeared

Adequate at the Time of the Inspection

COOLING EQUIPMENT STYLE:Split System (Outside Condenser w/

Inside Evaporator)Approximate Cooling Capacity in Tons :

Each of the Two Units Is Rated at 2.5 Tonsof Cooling Capacity

COOLING EQUIPMENTMANUFACTURER:

Average Service Life of A/C Unit is 12-15Years

CARRIERApprox. Age of Condensing Unit : Both

Units Are Approximately 15 Years Old

PLUMBING WASTE PIPING MATERIAL:Cast ironCopperNot Fully VisiblePVC

WATER HEATER SIZE AND POWERSOURCE:

50 GallonsGas-Fired Water HeaterInsufficiently Sized Water HeaterBTU or WATT Input Rating : 38,000 BTU

WATER HEATER MANUFACTURER:RheemWater Heater Statistical Service Life is

13 years.Approximate Age in Years :

Approximately 3 Years Old

ELECTRICAL SERVICE:Below groundCopper Service Conductors240 voltsLocation of Main Service Disconnect :

Northwest Corner of Basement

SERVICE PANEL AMPACITY:200 AMPOvercurrent Protection Devices : Circuit

Breakers

SERVICE PANEL BRAND:CUTLER HAMMER

BRANCH CIRCUIT CONDUCTORS:CopperNo Spare Breaker Spaces Are Available

For Additional CircuitryNot fully visible# of Circuits Used/# of Circuits Available

for Use : 30 Used/0 Available

WIRING METHODS:Electrical Metallic Tubing EMT (Conduit)Not Fully VisibleArmored Cable (BX)

ELECTRICAL GROUNDINGCONDUCTOR/CLAMP LOCATION:

The Bonding/Grounding Is Defective andShould Be Repaired by a QualifiedElectrical Contractor As Soon As Practical

Water Pipe Grounding Clamp

HEAT TYPE:Forced Air Ducted SystemAir Filter Size : 16 x 20 x 1

HEATING ENERGY SOURCE:Natural Gas

HEATING EQUIPMENTMANUFACTURER:

VENTILATION:Ducted Exhaust Fans in Bath/s

DoeDomicile Consulting

Page 2 of 321818 S Halcyon Drive

Page 3: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

BTU or KW Input per Hour : Both UnitsAre Rated at 88,000 BTU

Average Service Life of a Gas-FiredForced-Air Furnace is 15-20 years

CARRIERApproximate age of unit : Both Units Are

Approximately 15 Years Old

Kitchen Exhaust Ducted to Outside

VEGETATION/GRADING/DRAINAGE:Inadequate Clearance between Masonry

Wall and Exterior Grade Level

FLOOR STRUCTURE:Unable to Determine

CRAWLSPACE ACCESS:No Crawlspace

COUNTERTOPS/CABINETS:Natural Stone CountertopsWood Kitchen Cabinets

ATTIC INSULATION AND VAPORRETARDERS:

No Attic Access

FIREPLACES:Metal Pre-Fab Fireplace. Can Be Used

With Wood or Natural Gas

MAIN FLOOR BEAM AND POSTS:No Visible Posts or Beams

Items

A. EXTERIOR WALLS, GROUNDS, CHIMNEYS, ETC.Comments: Not Functioning or in need of repair

(1) The presence of soil against thelower front exterior wall presents anincreased risk for moisture saturationof the masonry, moisture penetrationto the interior, and moisture damage.It is recommended that the plantingbed/exterior wall be provided with amoisture barrier or that it be removedaltogether.

A. Item 1(Picture) Risk for Moisture Saturation and Moisture Damage

(2) The front gate requires excesseffort to operate and should berepaired as needed.

A. Item 2(Picture) Front Gate

DoeDomicile Consulting

Page 3 of 321818 S Halcyon Drive

Page 4: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

A. Item 3(Picture) Moisture Management RepairsRecommended

A. Item 4(Picture) Proper Configuration ofExterior Masonry Caulk Joint

A. Item 5(Picture) Risk for Moisture Penetration andMoisture Damage

A. Item 6(Picture) Caulking Recommended(3) The mortar joints at the corners of the stone window sills and between all limestone copings/sills shouldbe raked out and sealed instead with a high-quality masonry caulking compound to reduce the risk of moisturesaturation, moisture intrusion to the interior, and damage to the brick masonry below the sill.

(4) The ponding at the garage apronpresents a risk for icing, falls, andinjuries. The townhome associationshould make any necessary repairs.

A. Item 7(Picture) Low Area

DoeDomicile Consulting

Page 4 of 321818 S Halcyon Drive

Page 5: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

A. Item 8(Picture) Moisture Related HardwoodFlooring Damage

A. Item 9(Picture) Suspect Area(5) Evidence of through-wall moisture penetration and hardwood flooring moisture damage was noted at thewest balcony doorway. The door assembly as well as the adjacent masonry and flashing should be carefullyevaluated and repaired as needed. The hardwood flooring damage should be addressed as part of the overallhardwood flooring repair recommended elsewhere in this report.

(6) The wood decking at the eastpenthouse balcony is badlydeteriorated. It is recommended thatthe existing decking boards bereplaced with synthetic or compositedecking boards which require muchless maintenance than natural wooddecking. It is further recommendedthat, once the existing decking boardsare removed, that the underlying deckframework and roof covering theevaluated and repaired or replacedas needed. It wouldn't make littlesense to install a high performancedecking system on top of adeteriorated framework or over a roofcovering which is nearing the end ofits useful life.

A. Item 10(Picture) Deteriorated Decking

DoeDomicile Consulting

Page 5 of 321818 S Halcyon Drive

Page 6: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

(7) The east roof scupper is partiallydetached and is likely allowingmoisture penetration into the exteriorwall cavity. A qualified sheet metalcontractor should make the necessaryrepairs as soon as practical.

A. Item 11(Picture) East Wall Scupper

A. Item 12(Picture) Deteriorated Caulking

A. Item 13(Picture) Missing Caulking(8) The exterior caulking is largely deteriorated and at the end of its useful life. It is recommended that all ofthe exterior caulking be removed and replaced by a qualified architectural sealant contractor in order to reducethe risk for moisture penetration, moisture damage, drafts, energy losses, pest entry, etc.

(9) Poor caulking techniques wereused at the main front entry landingarea in an apparent attempt to stopmoisture penetration. It isrecommended that themasonry/concrete joints in this areabe carefully prepared and properlycaulked by a qualified contractor.

A. Item 14(Picture) Apparent Attempts to Stop Moisture Penetration

DoeDomicile Consulting

Page 6 of 321818 S Halcyon Drive

Page 7: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

B. GARAGES & OUTBUILDINGSComments: Not Functioning or in need of repair

(1) It is recommended that thedrywall around the hose bibb in thegarage be covered with fiberglassresin panel (FRP) or equivalentprotective panel to reduce the risk formoisture damage.

B. Item 1(Picture) Moisture Protection Recommended

B. Item 2(Picture) Sealed Ventilation Openings

B. Item 3(Picture) Significant Risk for Indoor AirContamination(2) Built-in garages such as the one at the subject townhome presented increased risk for contamination ofindoor air with vehicle exhaust. This is why, at the time of construction, the overhead door required multipleventilation openings. These openings have been sealed in an apparent attempt to reduce energy losses andto provide a warmer floor surface in the kitchen area during cold weather. The installation of the electricresistance garage heater was also likely intended to prevent cold floor temperatures during more extremewinter weather. The presence of the large HVAC return air grille just inside the personnel door between theparking garage and the lower-level family room creates a significant risk for vehicle exhaust and other indoorcontaminants being drawn into the living space.

The optimal approach to energy efficiency, indoor comfort, and indoor air quality concerns with be to removethe existing drywall ceiling in the garage and apply high density spray foam insulation to the underside of thefloor system before installing a new fire rated gypsum wallboard ceiling. In addition, the use of blower door

DoeDomicile Consulting

Page 7 of 321818 S Halcyon Drive

Page 8: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

guided air sealing is recommended in order to find and eliminate all air breaches between the built-in garage inthe living space thereby reducing the risk for indoor air contamination.

Once the insulation and air sealing improvements are performed, the garage can be ventilated so that vehicleexhaust, particularly dirty and unhealthy during cold startups, is less likely to be drawn into the home.

(3) The photo-electric safety sensorsfor the automatic overhead garagedoor should be placed within 4 to 6inches of the garage slab. Theexisting safety sensors are higherthan this standard dictates andpresent an undue risk for crushing andentrapment injuries. Repair by alicensed and competent garage doorspecialist is recommended.

B. Item 4(Picture) Unsafe Location

(4) It is recommended that the lowerhorizontal portions of the garage wallsbe provided with moisture/moldresistant drywall to prevent ongoingand accelerating moisture damagefrom slush, rising damp, etc.

B. Item 5(Picture) Moisture Damaged Wallboard

(5) The electrical receptacles in thegarage should be provided with GFCIprotection in order to reduce the riskfor electrocution.

B. Item 6(Picture) Missing Shock Protection

DoeDomicile Consulting

Page 8 of 321818 S Halcyon Drive

Page 9: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

C. ROOF COVERING, ROOF FLASHINGS, ROOF DRAINAGE.Comments: Not Functioning or in need of repair

D. STRUCTURE & FOUNDATIONComments: Inspected

E. ELECTRICAL SYSTEM, GROUNDING, CONNECTED DEVICES AND FIXTURESComments: Not Functioning or in need of repair

(6) The garage personnel doorshould be provided with a self-closingdevice and with properly fittingweatherstripping in order to reducethe risk for indoor air contaminationwith vehicle exhaust and othersubstances.

B. Item 7(Picture) Missing Weatherstripping at Garage Personnel Door

Copper and aluminum should not bejoined together due to the risk forgalvanic corrosion and deterioration.The corroded downspout at the rear ofthe home should be repaired orreplaced as needed by a qualifiedsheet metal specialty contractor.

C. Item 1(Picture) Galvanic Corrosion

Very little of the basement foundation walls were visible at the time of the inspection due to the finished lowerlevel walls.

(1) The evaluation of the low-voltageequipment in the home: alarm,communication, audiovisual, etc., isbeyond the scope of the homeinspection and should be performedby a qualified low-voltage electricalcontractor.

E. Item 1(Picture) Alarm Panel

DoeDomicile Consulting

Page 9 of 321818 S Halcyon Drive

Page 10: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

(2) The GFCI receptacle at the frontexterior wall is defective, does notprovide electrical power, and shouldbe replaced.

E. Item 2(Picture) Defective Receptacle

(3) The grounding electrodeconductor is not properly secured tothe water piping system or to theirclamps. The stranded coppergrounding conductor has beensqueezed between the clamp and thepiping. This is not allowed and isunsafe since it makes the clamp proneto loosening and can reduce thesafety and effectiveness of thebonding and grounding system. Theexisting clamp should be replacedwith ones that can properly secure thegrounding electrode conductor into ascrew terminals. Further evaluationand repair by a licensed andcompetent electrical contractor isrecommended.

E. Item 3(Picture) Improper Grounding Connection

(4) A bonding jumper should beinstalled across the water meter by aqualified electrician in order to helpinsure the continuity of thebonding/grounding safety system.

E. Item 4(Picture) Missing Bonding Jumper

DoeDomicile Consulting

Page 10 of 321818 S Halcyon Drive

Page 11: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

(5) It is recommended that additionalinterior lighting be provided in thegarage for safety and convenience.

E. Item 5(Picture) Minimal Garage Interior Lighting

DoeDomicile Consulting

Page 11 of 321818 S Halcyon Drive

Page 12: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

E. Item 6(Picture) Half-Size Breakers

E. Item 7(Picture) List of Approved Breakers

DoeDomicile Consulting

Page 12 of 321818 S Halcyon Drive

Page 13: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

E. Item 8(Picture) "QT" Breakers Not Listed(6) The electrical panel has been maxed out and no spare breaker spaces are available for future expansion.In addition, half-size breakers have been installed in the electrical panel in order to provide for additionalelectrical circuitry in the home. However, these breakers are forbidden by the local electrical code and are notlisted on the electrical service panel label as approved for use. It is strongly recommended that a qualifiedelectrical contractor further evaluate the electrical loads in the home, the adequacy of the existing distributionpanel, and make all necessary repairs, replacements or alterations to ensure safe and adequate electricalpower is provided.

(7) Multiple loose electricalreceptacles were noted in the home.Loose receptacles can result inarcing/sparking during use and anincreased risk of fire in the home. Allof the receptacles in the home shouldbe evaluated and repaired as neededby a licensed electrician.

E. Item 9(Picture) Loose Receptacle

(8) The missing cover at the kitchenceiling light fixture should be furnishedand installed.

E. Item 10(Picture) Missing Cover

DoeDomicile Consulting

Page 13 of 321818 S Halcyon Drive

Page 14: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

F. PLUMBING SUPPLY, DRAINS, FIXTURES AND VENTSComments: Not Functioning or in need of repair

(9) Extinguished or otherwiseinoperative luminaires (light bulbs)were noted during the inspection. Allof the lighting in the home should bemade fully operational for the finalwalk-through so that the properoperation of all the lighting in thehome can be verified anddifferentiated from defective switches,fixtures, etc.

E. Item 11(Picture) Main Entry Closet Lighting

E. Item 12(Picture) Unsafe Receptacle Location

E. Item 13(Picture) Island Receptacle Standards(10) Installation of at least one GFCI electrical receptacle is recommended on the kitchen island/peninsula inorder to comply with modern safety codes and to increase the food preparation functionality of the workspace.

DoeDomicile Consulting

Page 14 of 321818 S Halcyon Drive

Page 15: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

F. Item 1(Picture) Non-Conforming Installation

F. Item 2(Picture) Non-Conforming Sink Drain(1) The small utility sink in the laundry closet does not have a properly configured drain and does not conformto plumbing safety standards. A qualified plumbing contractor should evaluate the sink in consultation with thebuyer to determine if repair or removal is the appropriate option.

(2) A small piping leak was notedabove the water pressure boosterassembly. Repair by a qualifiedplumbing contractor is recommended.

F. Item 3(Picture) Incipient Leaking

(3) It is recommended that the floordrain backup prevention device in thelower-level mechanical room beremoved and either serviced orreplaced to ensure its properoperation in the future.

F. Item 4(Picture) Floor Drain Backup Prevention Device

DoeDomicile Consulting

Page 15 of 321818 S Halcyon Drive

Page 16: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

G. HEATING, AIR CONDITIONING, VENTILATION, AND GAS APPLIANCE SYSTEMSComments: Not Functioning or in need of repair

(4) None of the toilets are adequatelysecured to the floor. This can result indeformation of the wax ring seal,leaking, and other damage. Thetoilets should be evaluated by alicensed and competent plumber inorder to determine if removal andreinstallation as necessary.

F. Item 5(Picture) Loose Toilet

(1) The existing furnace-mountedhumidifiers rely on standing water forhumidification of the conditioned air.These units are difficult to clean andcan allow molds, bacteria, and otherbiologicals to grow inside theconditioned air stream. They shouldbe replaced with a more indoor airquality friendly unit by a licensedHVAC contractor.

G. Item 1(Picture) Furnace Mounted Humidifier

DoeDomicile Consulting

Page 16 of 321818 S Halcyon Drive

Page 17: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

G. Item 2(Picture) Condensate Drain

G. Item 3(Picture) Air ConditioningCondensate Drain Piping Trap

(2) The installation of a air conditioning condensate trap is recommended in order to reduce the risk forenergy losses and for splashing and leaking at the evaporator drain pan. Repair by a qualified HVACcontractor is recommended.

(3) The water heater is undersizedfor the needs of the home and cannotsupply adequate hot water to fill themaster bathroom bathtub. A qualifiedplumbing contractor should ensurethat adequate hot water is availablefor the needs of the home.

G. Item 4(Picture) Undersized Water Heater

DoeDomicile Consulting

Page 17 of 321818 S Halcyon Drive

Page 18: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

(4) The use of 1 inch pleatedcartridge filters can reduce therequired airflow across the heatexchanger or the evaporator coil to apoint where the capacity andefficiency of the HVAC equipment issignificantly compromised. Therefore,it is recommended that, especiallyduring the heating season whenairflow is even more critical, a moreopen weave and less restrictive airfilter be used. These less restrictivefilters are sometimes derisivelyreferred to as "rock catchers" sincesmaller particles may not be caught bythese open weave filters. Thehomeowner can use a light spraycoating of a non-stick cooking sprayon the upstream side of the air filter inorder to enhance dust capture on thistype of HVAC air filter.

G. Item 5(Picture) Standard 1 Inch Filter

(5) The large gaps in the frameworkof the return air plenum present a riskfor contaminated air being drawn intothe HVAC duct system. The return airplenum should be sealed by aqualified contractor.

G. Item 6(Picture) Openings within the Return Air Plenum

DoeDomicile Consulting

Page 18 of 321818 S Halcyon Drive

Page 19: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

(6) Air-conditioning condensing unitfor the lower level HVAC unit islocated at the penthouse balcony.Typically, air-conditioning filter dryersare installed on refrigerant line sets ofsuch length. A qualified HVACcontractor should evaluate theinstallation and install anycomponents which may improveefficiency, capacity, longevity, etc. ofthe air-conditioning system G. Item 7(Picture) Missing Device

(7) Gaps were noted in the supplyand return air duct work and/or in theHVAC plenums. These gaps createair leaks which can reduce theefficiency of the HVAC unit, and whichcan negatively impact both indoor aircomfort and indoor air quality. Thesupply and return air ducts should besealed using approved materials andmethods; duct mastic is the preferredmaterial for duct sealing. G. Item 8(Picture) HVAC Air Leakage

(8) The presence of moisture stainingon the drywall ceiling around the topfloor furnace supply duct penetrationis indicative of summertimecondensation on the surface of thecold metal supply ducts. This can bedue to inadequately sealed HVACducts and/or inadequately insulatedHVAC supply ducts. The inspectorwas unable to access the attic spaceabove the top floor ceiling and cannotreport definitively on conditionstherein. It is recommended thataccess be provided to this area sothat a thorough evaluation can beperformed and recommendations forrepairs or upgrades can be providedduring the buyers due diligenceprocess.

G. Item 9(Picture) Moisture Staining around Supply Ducts Penetrationthrough Ceiling

DoeDomicile Consulting

Page 19 of 321818 S Halcyon Drive

Page 20: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

H. INSULATION, VENTILATION, ATTICS, ETC.Comments: Not Functioning or in need of repair

(9) The elevated supply plenumsheet metal temperature noted duringthe operation of the upper-levelfurnace may be indicative of poor ductdesign/installation or other HVAC ductpressure issues. Excessive heatbuildup can result in short cycling ofthe furnace and a reduced servicelife. It is recommended that aqualified HVAC contractor performduct pressure testing and any othernecessary diagnostics during thebuyers due diligence process.

G. Item 10(Picture) Elevated Temperature

(10) It is recommended that theHVAC supply duct underneath thekitchen sink be properly configured toprevent airflow losses and to providemaximum heating and cooling in theintended area.

G. Item 11(Picture) Toe Kick Supply Duct

(11) The gaps at the register bootsshould be sealed to reduce energylosses, to promote optimal HVACairflow, and to prevent futuredisplacement of the inadequatelysecured duct boots.

G. Item 12(Picture) Duct Leakage

DoeDomicile Consulting

Page 20 of 321818 S Halcyon Drive

Page 21: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

I. FIREPLACES, WOODSTOVES, ETC.Comments: Inspected

J. INTERIORS AND FINISHESComments: Not Functioning or in need of repair

H. Item 1(Picture) Low Performance Vent Termination

H. Item 2(Picture) High-Quality Vent Damper The exhaust vent dampers on the exterior walls should be replaced with high-quality, gasketed, vent dampersin order to reduce drafts and energy losses.

The National Fire Protection Agency recommends that wood-burning fireplaces be thoroughlyevaluated when a home changes ownership. Evaluation of the fireplace/s in the home by a qualifiedspecialty contractor, preferably one who is a member of the Chimney Safety Institute of America, isrecommended.

DoeDomicile Consulting

Page 21 of 321818 S Halcyon Drive

Page 22: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

J. Item 1(Picture) Uneven Finish Application

J. Item 2(Picture) Splotchy Color(1) The refinishing of the hardwood flooring was not performed in a workmanlike manner. Splotchy areas,areas of inadequate floor finish, and areas of excessive floor finish accumulation will noted. In addition, someportions of the hardwood flooring and hardwood stair treads exhibit excessive wear and were not refinished. Itis recommended that a qualified hardwood flooring finishing contractor make all repairs needed to provide auniform and properly protective finish on all hardwood flooring areas.

(2) The wall tile next to the masterbathroom toilet should be repaired toprevent detachment, failure, etc.

J. Item 3(Picture) Loose Tile

DoeDomicile Consulting

Page 22 of 321818 S Halcyon Drive

Page 23: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

J. Item 4(Picture) Partial Handrail

J. Item 5(Picture) Missing Railing(3) Winding stairs presents an increased risk for falls and injuries. Therefore, secure, continuous, andgraspable handrails should be installed along the wider portion of the winding stairs in order to reduce this risk.As currently configured, occupants are encouraged to walk the narrow or more dangerous portion of thestairway and do not have access to an easily grasped railing continuous from the top landing to the bottomlandings as is required. Repair by a qualified carpenter or custom stair builder is recommended in order toreduce the risk for falls and injuries.

(4) The upper level guest bathroomcountertop is stained and should berepaired as needed by a qualifiedcountertop specialty contractor.

J. Item 6(Picture) Countertop Stain

DoeDomicile Consulting

Page 23 of 321818 S Halcyon Drive

Page 24: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

J. Item 7(Picture) Corroded Fasteners

J. Item 8(Picture) Corroded and Abandoned Fasteners(5) The corroded fasteners in the upper-level guest bathroom should be replaced with stainless steelfasteners. The abandoned fasteners should be removed and the adjacent wall tiles repaired or replaced.

(6) The non-functioning drawer panelat the upper-level guest bathroom sinkcabinet should be secured to preventexcess movement, failure, etc.

J. Item 9(Picture) Loose Panel

(7) Miscellaneous caulking andgrouting repairs are required at thetub/shower enclosures in order toeliminate mold growth and to reducethe risk for moisture intrusion anddamage.

J. Item 10(Picture) Caulking Needed

DoeDomicile Consulting

Page 24 of 321818 S Halcyon Drive

Page 25: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

K. WINDOWS, DOORS, SKYLIGHTSComments: Not Functioning or in need of repair

(8) FYI: The moisture staining at theupper southwest corner of thesouthwest guest bedroom appears tohave resulted from leakage at thescupper above. This area should bemonitored for signs of recurringmoisture.

J. Item 11(Picture) Moisture Staining

(9) The large gap between thekitchen backsplash and countertop isindicative of inadequate countertopsupport. The full extent of the repairswill not be known until some cabinetdisassembly is performed. It isstrongly recommended that a qualifiedcontractor provide a plan and budgetfor repair during the buyers todiligence process.

J. Item 12(Picture) Gap Between Backsplash and Countertop

DoeDomicile Consulting

Page 25 of 321818 S Halcyon Drive

Page 26: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

K. Item 1(Picture) Inadequate Clearance And DustAccumulation from Continued Drafts

K. Item 2(Picture) Poorly Fitted Door(1) The front entry door system is defective in multiple regards including but not necessarily limited to:defective storm door hydraulic closers; inadequate weatherstripping contact; and a poor fit between the doorand doorjamb. A qualified contractor should make all necessary repairs for proper operation and draftprevention.

(2) The middle and right-handwindows at the lower level west walldo not fit properly along the top edgeand are significantly drafty. Aqualified contractor should make therepairs needed to reduce drafts andenergy losses.

K. Item 3(Picture) Drafty Windows

DoeDomicile Consulting

Page 26 of 321818 S Halcyon Drive

Page 27: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

(3) Advanced rot was noted at theeast balcony sliding door assembly aswell as at adjacent interior surfaces.The age and condition of the slidingdoor assembly indicates thatreplacement, rather than repair, is theappropriate option. A qualifiedcontractor should provide a plan andbudget during the buyers duediligence process.

K. Item 4(Picture) Advanced Rot

(4) It is recommended that the gapsand cracks on the exterior windowcladding and exterior window framesbe professionally sealed againstongoing moisture penetration.

K. Item 5(Picture) Caulking Recommended

(5) The entry door to the southwestguest bedroom does not latch whenplaced in the closed position andshould be repaired for properoperation.

K. Item 6(Picture) Failure to Latch

DoeDomicile Consulting

Page 27 of 321818 S Halcyon Drive

Page 28: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

L. INSTALLED APPLIANCESComments: Not Functioning or in need of repair

(6) The master bedroom entry doordoes not remain in position and opensof its own volition when left in thepartially open position. A qualifiedcontractor should repair the door sothat it remains in position whenpartially opened.

K. Item 7(Picture) Master Bedroom Entry Door

(7) The left-hand door panel at themain entry closet has a defectivebullet catch. The door should berepaired so that it operates asintended.

K. Item 8(Picture) Entry Closet Door

DoeDomicile Consulting

Page 28 of 321818 S Halcyon Drive

Page 29: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

(1) The corrugated vent hose for theclothes dryer is prohibited by allappliance manufacturers due to it'spoor airflow characteristics. This canresult in increased drying times,reduced equipment life, and anincreased risk of fire from lint build-up.The existing vent hose should bereplaced with smooth wall metal ventpiping.

L. Item 1(Picture) Prohibited Material

(2) Heavy lint build-up was notedinside the vent passages of theclothes dryer. Regular cleaning isrecommended in order to reducedrying times, increase equipmentservice life, and reduce the risk of adryer fire.

L. Item 2(Picture) Lint Buildup

(3) The control panel for the built-inoven is defective. This conditionpresent significant safety andconvenience issues. The built-in ovenshould be repaired or replaced.

L. Item 3(Picture) Built-In Oven Control Panel

(4) The refrigerator icemaker was inthe off position at the time of theinspection. It is recommended thatthe proper operation of the refrigeratoricemaker be demonstrated at the timeof the final walk-through prior toclosing.

L. Item 4(Picture) Icemaker

DoeDomicile Consulting

Page 29 of 321818 S Halcyon Drive

Page 30: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

M. OTHERComments: Not Functioning or in need of repair

(5) The food waste disposer is agedand deteriorated. Plans should bemade for its near-term replacement.

L. Item 5(Picture) Grinding Chamber

(6) Is recommended that the built-indishwasher be cleaned according tothe manufacturer's instructions prior tomove-in.

L. Item 6(Picture) Interior of Dishwasher

M. Item 1(Picture) Access to Wall Cavity

M. Item 2(Picture) Mold-like Material

DoeDomicile Consulting

Page 30 of 321818 S Halcyon Drive

Page 31: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

All of the recommendations for repairs or alterations that are contained in this report should be performed by licensed and competent contractors withexpertise in the appropriate trade or specialty. It is recommended that the repairs/alterations be completed prior to closing. The contractor/s whoperform the recommended repairs at the seller's direction should provide the buyer/client with all appropriate documentation regarding the materialsand methods used in the work. A list of contractors who have been rated and recommended by consumers can be found at www.angieslist.com

(1) Evidence of mold growth was noted on the interior side of the exterior sheathing gypsum wallboard. Theinspector was unable to determine the full extent nor the cause of this apparent moisture related condition.

Mold growth results from moisture on organic strata and is first and foremost a moisture problem. The sourceof the moisture that is the proximal cause of the mold-growth should be found and eliminated before finalremediation is performed. Initial remediative steps may be advisable in order to reduce the release of moldspores, fungal fragments, and mycotoxins during the moisture investigation and repair process. Small areas ofmold (10 square feet or less) can be remediated by the homeowner successfully. An EPA approvedmildewcide with residual mold inhibiting properties (Concrobium Brand) can be found at major homeimprovement stores. Relatively non-porous surfaces such as tile, laminate, concrete, etc. should be surfacecleaned with this type of product and kept dry. Semi-porous surfaces such as wood framing and sheathing canalso be cleaned in this manner if fungal growth hasn't degraded the material significantly. Porous surfacessuch as paper-faced gypsum drywall, cellulose insulation, etc. should be removed and replaced.

Air sampling and bulk sampling for mold is typically not required for successful remediation. For routineassessments in which the goal is to identify possible mold contamination problems before remediation, it isusually unnecessary to collect and analyze air or settled dust samples for mold analysis because decisionsabout appropriate intervention strategies can typically be made on the basis of a visual inspection. Also,sampling and analysis costs can be relatively high and the interpretation of results is not straightforward. Airand dust monitoring may, however, be necessary in certain situations, including 1) if an individual has beendiagnosed with a disease associated with fungal exposure through inhalation, 2) if it is suspected that theventilation systems are contaminated, or 3) if the presence of mold is suspected but cannot be identified by avisual inspection or bulk sampling.

M. Item 3(Picture) Damaged Detector

M. Item 4(Picture) RecommendedDetector Placement

(2) Smoke and carbon monoxide detectors are relatively inexpensive considering the importance of theirfunction. It is recommended that the smoke and carbon monoxide detectors be replaced with new units uponmoving into the home. Each level of living space should have both types of detectors installed. The installationof hard-wired smoke detectors in each bedroom is recommended as is the inter-connecting of all smoke andCO detectors. This is recommended so that an alarm in one area of the home would be able to alertoccupants at all areas of the home.

DoeDomicile Consulting

Page 31 of 321818 S Halcyon Drive

Page 32: Inspection Report · 2/3/2017  · penthouse balcony is badly deteriorated. It is recommended that ... to provide a warmer floor surface in the kitchen area during cold weather. The

INVOICE

Domicile Consulting2545 W Diversey Ave Suite 206Chicago IL 60647312-488-1461Inspected By: Dan Cullen

Inspection Date: 1/16/2017Report ID:

Customer Info: Inspection Property:

James Doe

Customer's Real Estate Professional:

1818 S Halcyon DriveChicago IL

Inspection Fee:

Service Price Amount Sub-Total3 Bedroom Attached Townhome 525.00 1 525.00

YELP / A.L. Discount -25.00 1 -25.00

Tax $0.00Total Price $500.00

Payment Method: Credit CardPayment Status: Invoice SentNote:

DoeDomicile Consulting

Page 32 of 321818 S Halcyon Drive