0 ~JAN 19 i-J FPL L-2001-009 10 CFR 50.55a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re: Turkey Point Unit 4 Docket No. 50-251 Inservice Inspection Report Attached are the following reports for Turkey Point Unit 4 in accordance with the provisions of the ASME Code, Section XI: Form NIS-I Owners' Report for Inservice Inspections. Form NIS-2 Owners' Report for Repairs or Replacements. Form NIS-BB Owners' Data Report for Eddy Current Examination Results. Summary of Visual Examinations and Functional Testing of Snubbers. Summary of Inservice Inspection Examinations. Summary of IWE Examinations. Summary of System Pressure Testing. Should there be any questions concerning this report, please contact US. Very truly yours, R. J. Hovey Vice Presid nt Turkey Point Plant OIH Attachments cc: Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, Turkey Point Plant an FPL Group company

Upload: others

Post on 13-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

0 ~JAN 19 i-J

FPL L-2001-009 10 CFR 50.55a

U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555

Re: Turkey Point Unit 4 Docket No. 50-251 Inservice Inspection Report

Attached are the following reports for Turkey Point Unit 4 in

accordance with the provisions of the ASME Code, Section XI:

Form NIS-I Owners' Report for Inservice Inspections.

Form NIS-2 Owners' Report for Repairs or Replacements.

Form NIS-BB Owners' Data Report for Eddy Current Examination

Results.

Summary of Visual Examinations and Functional Testing of

Snubbers.

Summary of Inservice Inspection Examinations.

Summary of IWE Examinations.

Summary of System Pressure Testing.

Should there be any questions concerning this report, please contact

US.

Very truly yours,

R. J. Hovey Vice Presid nt Turkey Point Plant

OIH

Attachments

cc: Regional Administrator, Region II, USNRC

Senior Resident Inspector, USNRC, Turkey Point Plant

an FPL Group company

Page 2: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT UNIT 4

2000 REFUELING OUTAGE

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS

Page 3: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS Page 1 of 7

1. Owner: Florida Power and Light Company 700 Universe Blvd. Juno Beach, Florida 33408

2. Plant: Florida Power & Light Company Turkey Point Nuclear Power Plant 9760 SW 344 Street Florida City, Florida 33035

3. Plant Unit: 4

5. Commercial Service Date: September 7, 1973

7. Components Inspected:

4. Owner Certificate of Authorization (if required): N/A

6. National Board Number for Unit: N/A

Component or Manufacturer Manufacturer State or or Installer Province National Board No. Appurtenance or Installer Sra o o Serial No. No.

Reactor Pressure Vessel Babcock and 610-0116 N/A N-160 Wilcox

Regenerative HeatN/NA exhner Westinghouse 4E200 N/A N/A Exchanger

Reactor Coolant System Bechtel N/A N/A N/A

Reactor Coolant Pump A Westinghouse 5-618J713 N/A N/A

Safety Injection System Bechtel N/A N/A N/A

RHR System Bechtel N/A N/A N/A

16A-6341-1 ,2,3 Steam Generator A, B. C Westinghouse FSGT-2991, N/A N/A

2992, 2993

Main Steam System Bechtel N/A N/A N/A

Auxiliary Feedwater Bechtel N/A N/A N/A

Main Feedwater System Bechtel N/A N/A N/A

Component Cooling Bechtel N/A N/A N/A

Page 4: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-1 Report (continued) Page 2 of 7

Owner: Florida Power & Light Company, 700 Universe Blvd. Juno Beach, Florida 33408

Plant: Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035

Plant Unit: 4 Owner Certificate of Authorization (if required) N/A Commercial Service Date: September 7, 1973 National Board Number for Unit: N/A

8. Examination Dates: from 9/25/00 to 10/23/00

9. Inspection Period Identification: Second Period, from 04/15/97 to 04/14/01.

10. Inspection Interval Identification: Third Interval, from 04/15/94 to 04/14/04.

11. Applicable Edition of Section XI: 1989, No Addenda, (IWE) 1992/1992 Addenda

12. Date/Revision of Inspection Plan: June 30, 1998/Revision 1.

13. Abstract of examinations and test. Include a list of examinations and tests and a

statement concerning status of work required for the inspection plan.

Inservice Examinations of selected Class 1 and 2 components and piping systems of Florida

Power and Light's (FPL) Turkey Point Unit 4 was performed during the 2000 Refueling

Outage. This outage began on September 25, 2000 and ended October 23, 2000. This was

the third outage of the second period of the third ten-year interval.

The components and piping systems examined were selected in accordance with the Third

Ten-Year Inservice Inspection Program, which was prepared in accordance with the

requirements of the American Society of Mechanical Engineers (ASME) Section XI, 1989 Edition, No Addenda.

Manual and Automated Ultrasonic, Visual, Magnetic Particle, and Liquid Penetrant non

destructive methods were used to examine components, piping, and their supports. FPL

personnel supported by Washington International Group personnel performed the

examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary

and Turkey Point Unit 4 IWE Summary for examination scope and results.

FPL personnel supported by Westinghouse, Zetec, and NDE Technology personnel conducted

Eddy Current examinations on Steam Generators A, B, and C from October 04, 2000 through

October 09, 2000. Ten tubes were plugged during this outage. See the attached NIS-BB

report for the summary of examination results.

The Feedwater Nozzle piping augmented examinations of all 3 steam generators were

conducted utilizing the P-Scan automated ultrasonic examination system. The entire area

from the nozzle ramp to a point one-pipe diameter past the elbow weld was examined with

ultrasonics. No reportable indications were noted.

Snubber visual examinations and functional testing were conducted in accordance with

ASME Section XI and Turkey Point Technical Specifications as allowed under Relief

Request number 4. Basic-PSA, Inc supplied examination and testing services. See the

attached report: Summary of Visual Examinations and Functional Testing of Snubbers for

examination scope and results.

Page 5: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-1 Report (continued) Page 3 of 7

Owner: Florida Power & Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant: Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035 Plant Unit: 4 Owner Certificate of Authorization (if required) N/A Commercial Service Date : September 7, 1973 National Board Number for Unit: N/A

System pressure testing was conducted by FPL visual examiners to meet the requirements of

ASME Section XI Code and Turkey Point Technical Specifications as allowed under Relief Request number 9, 11, 12, and 16 and implemented through applicable procedures. See the attached report: Summary of System Pressure Testing for test boundaries and results.

IWE examinations were conducted in accordance The Containment Building Metallic Liner

Inservice Inspection Program For Turkey Point Unit 3 & 4, which was written in accordance

with ASME Section XI 1992 Edition, 1992 Addenda and is subject to the limitations and

modifications of 10 CFR 50.55a(b)(2), 10 CFR 50.55a(g)(4), and 10 CFR 50.55a(g)(6). The

requirements for the first inspection period as required by 10 CFR50.55a (g)(6)(ii)(B)(1) have

been met as applicable to IWE, Program B of ASME Section XI.

The completed examination percentages for the second period meet the requirements of

Program B of ASME Section XI and applicable relief requests. A listing of examinations

performed during this outage is attached to this summary.

14. Abstract of Results of Examinations and Tests.

Class 1

Reactor Pressure Vessel

One-third of the studs and nuts were examined with Magnetic Particle and Ultrasonic

examination methods. One-third of the large and small washers was visually examined. No

reportable indications were identified.

Reactor Coolant Pump A

100% of the studs were examined with the ultrasonic method. No reportable indications were

identified.

Pressurizer

Pressurizer vessel welds and nozzle inner radii were examined with the ultrasonic method.

No reportable indications were identified.

Steam Generators (Eddy Current)

Eddy Current examinations were performed of the tubing of the three Steam Generators. The

results of the examinations are detailed in the NIS-BB report.

Page 6: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-1 Report (continued) Page 4 of 7

Owner: Florida Power & Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant: Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035 Plant Unit: 4 Owner Certificate of Authorization (if required) N/A Commercial Service Date: September 7, 1973 National Board Number for Unit: N/A

Regenerative Heat Exchanger

Per Relief Request # 3, a VT-3 visual examination was performed near the beginning of the

outage to look for accumulated boric acid crystals and evidence of leakage and a VT-2 visual

examination was performed during the system leakage test to look for evidence of leakage. No reportable indications were identified.

Reactor Coolant Piping

Reactor Coolant piping welds and supports were examined with surface, volumetric and visual methods. No reportable indications were identified.

Safety Injection Piping

Safety Injection piping welds and supports were examined with the surface and visual methods. One support was found to have a 0" clearance between the sliding plate and the angle iron (Refer to section 15, "Abstract of Corrective Measures"). No additional reportable indications were identified.

Residual Heat Removal Piping

One Residual Heat Removal piping integral attachment weld and support were examined with surface and visual methods. No reportable indications were identified.

Class 2

Steam Generator B

Steam Generator inlet and outlet bolting was examined with the visual method. No reportable indications were identified.

Main Steam Piping

Main steam piping welds were examined with volumetric and surface methods. Acceptable geometric indications were noted. No reportable indications were identified.

Main Feedwater Piping

Main Feedwater piping supports were examined with the visual method. No reportable indications were identified.

Augmented examinations were performed of the piping of the Steam Generator Feedwater nozzles ramp to a point one-pipe diameter past the elbow weld on all three loops with the

Page 7: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-1 Report (continued) Page 5 of 7

Owner: Florida Power & Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant: Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035 Plant Unit: 4 Owner Certificate of Authorization (if required) N/A Commercial Service Date: September 7, 1973 National Board Number for Unit: N/A

automated ultrasonic method. Acceptable geometric indications were noted. No reportable

indications were identified.

Auxiliary Feedwater

Auxiliary feedwater piping supports were examined with the visual method. One support was

found to have a discrepancy between the actual support configuration and the drawing (Refer

to section 15, "Abstract of Corrective Measures"). No reportable indications were identified.

Component Cooling Piping

Component Cooling piping supports were examined with the visual method. No reportable indications were identified.

IWE Examinations

General visual examinations were performed of selected containment penetrations and surfaces. The following areas are considered inaccessible:

Zone 1 Penetration 61A (due to Accumulator Tank platform)

Zone 2 Fuel Transfer Area - 740 to 1050 at elevation 14' to 39'6"

Zone 8 Fuel Transfer Area - 74' to 1050 at elevation 39'6" to 59'6"

Zones 13-18 Inaccessible areas on top of crane support throughout entire zone

Penetration 39 Fuel Transfer Tube (incased in concrete)

During the General Visual examinations one area was found to have separation between the moisture barrier liner plate and the concrete slab and another area was found to have coating damage (Refer to section 15, "Abstract of Corrective Measures").

15. Abstract of Corrective Measures

Support 3-SIH-56, on the Safety Injection system, was found to have 0" gap between the sliding plate and angle iron. An engineering evaluation showed the gap to be acceptable per Teledyne calculation TR-5322-106, Rev. 1(page 37 of Ref. 4). Engineering has issued drawing change (CRN-C-10835) to reflect the as-built condition. Refer to CR No. 00-1693.

Support 80117-H-341-18, on the Auxiliary Feedwater system, was found to have a drawing discrepancy and the threaded rod is in contact with a u-bolt. An engineering evaluation showed the condition to be acceptable. Engineering has issued drawing change (CRN-C10834) to reflect the as-built condition. Refer to CR No. 00-1725.

Page 8: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section XI.

Certificate of Authorization No. ,//A Expiration Date A1114

Date:/2/A Signed:____________ By _Mc a-C6 - C170c-

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida, and employed by Factory Mutual Insurance Company of Johnston, Rhode Island have inspected the components described in this Owner's Report during the period 4/8/99 to 10/23/00, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

r 745- L - 3 Z Inspect r' Signature National Board, State,

Province, and Endorsements

Date: 000

FORM NIS-1 Report (continued) Page 7 of 7

Owner: Florida Power & Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant: Turkey Point Nuclear Power Plant, 9760 SW 344 Street, Florida City, Florida 33035 Plant Unit: 4 Owner Certificate of Authorization (if required) N/A Commercial Service Date : September 7, 1973 National Board Number for Unit: N/A

Page 9: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

NIS-2 Reports

Page 10: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Abstract

The attached NIS-2 reports detail the repair/replacement of Class 1, 2 and 3 piping and components for Florida Power and Light Company, Turkey Point Unit 4. These repairs or replacements were performed prior to and during the fall 2000 refueling outage, between the dates of April 8, 1999 and October 23, 2000.

Piping and components were inspected/tested in accordance with Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel code "Rules for Inservice Inspection of Nuclear Power Components, "1989 Edition, No Addenda.

Page 11: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

NIS-2 LOG

Report No. Date

99-037-4 11/9/99 99-038-4 12/21/99 00-001-4 1/7/00 00-002-4 4/13/00 00-003-4 4/27/00 00-004-4 6/13/00 00-005-4 6/13/00 00-006-4 7/24/00 00-007-4 7/25/00 00-008-4 8/21/00 00-009-4 10/5/00 00-010-4 10/5/00 00-011-4 10/13/00 00-013-4 10/16/00 00-014-4 10/15/00 00-015-4 10/15/00 00-017-4 10/18/00 00-018-4 10/18/00 00-019-4 10/23/00 00-020-4 10/23/00 00-021-4 10/25/00 00-022-4 10/25/00 00-023-4 10/25/00 00-024-4 10/30/00 00-025-4 10/30/00 00-026-4 10/30/00 00-027-4 10/30/00 00-028-4 10/30/00 00-029-4 11/28/00 00-031-4 12/14/00

Page 12: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Name

700 Universe Blvd. Juno Beach, FL 33408

Date

SheetAddress

Turkey Point Plant Name

9760 SW 344 Street Florida City, FL 33035

d by

Address

Florida Power & LiahtNare

9760 SW 344 Street Florida City, FL 33035Address

Unit 4

WO#: 99017244 01 CR#: 99-1485

Repair Organization, P.O. No, Job No., tc.

Type Code Symbol Stamp N/A

Authorization Number N/A

Expiration Date N/A

4. Identification of System: Component Cooling Water System #: 30 Quality Group

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements

1955 Edition,

19 89 Edition,

N/A Addenda,

N/A Addenda,

N/A Code Case

N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

7. Description of Work:

REPLACED OUTLET SIDE CHANNEL HEAD COVER STUDS (6), NUTS (12), AND SCREWS (4).

8. Tests Conducted: Hydrostatic:

Other

Pneumatic

Pressure

Nominal Operating Pressure

psig Test Temperature

Owner

2. Plant

3. Work Performes

11/9/99

of 2

C

ASME Repaired, Code

Name of Name of Manufacturer National Other Year Replaced, or Stamp Component Manufacturer Serial Number Board Identification Built Replacememt Yes/No

ROD, THREADED, N/A N/A N/A STK CODE 29493 1 UNK REPLACEMENT NO (6) STUDS UTC 416044 FABRICATED, ASME SA-193, GR B7

NUT, CARBON N/A N/A N/A STK CODE 27963 1 UNK REPLACEMENT NO STEEL (12), ASTM UTC 423666 A-194 GRADE 2H

SCREW, CAP, N/A N/A N/A STK CODE 27122 1 UNK REPLACEMENT NO HEAVY HEX (4), UTC 373840 ASME SA-193, GR B7

dog F

99-037-4

Page 13: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks Bolted connection, no welding required.

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state or Province of Dade County end employed by Factory Mutual Insurance Company of Norwood, Ma.

have inspected the components described in this Owners Report during the period of 9/21/99 to 11/9/99

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss

of any kind arising from or connected with this inspection.

Commissions Il, /L - f 30S .... . ........ National Board. State, Providence, and Endorsements

Date __ _ _ _ _

99-037-4

Page 14: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

1. Owner

Pl ant

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Date 1 Name

700 Universe Blvd. Juno Beach, FL 33408 Sheet

Address

T-rk-~ Point Plant Unit

Name

9760 SW 344 Street Rorida City, FL 33035

WO#: 9901788

2/21/99

of 2

4

8 01 CR#: N/A

Address Repair Organization, P.O. No, Job No.. etc.

3. Work Performed by Rorida Power & Light Type Code Symbol Stamp N/A Name Authorization Number N/A

9760 SW 344 Street Rorida City, FL 33035 Expiration Date N/A Address

4. Identification of System: Intake Cooling Water System #: 19 Quality Group C

5. (a) Applicable Construction Code 931.1 19 55 Edition, N/A Addenda, ........N/.A ... Code Case

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 Edition, N/A Addenda, N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Manufacturer National Other Year Replaced, or Stamp

Component Manufacturer Serial Number Board Identification Built Replacememt Yes/No

Cover studs (14), A- Hayward 2298609390 N/A STK CODE 14188 2 UNK Replacement No

193 GR 7 UTC 394431

Nut, Heavy Hex 114) N/A N/A N/A STK CODE 44572 1 UNK Replacement No

A-194 GR 2H UTC 425631

7. Description of Work:

Replaced (14) cover studs and (14) nuts on cover.

3. Tests Conducted: Hydrostatic:

Other N/A

Pneumatic

Pressure N/A psig

Nominal Operating Pressure

Test Temperature N/A deg F

99-038-4

7• • ., u ,

Page 15: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

99-038-4

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of

the ASME Code, Section XI.

N/AType Code Symbol Stamp

N/A Expiration Date: N/ACertificate of Authorization No.

Date , "X/ -Owner or Owner's besignee, Title

CERTIFICATE OF INSERVICE INSPECTION

I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state or Province of Dade County and employed by Factory Mutual Insurance Company of Norwood, Ma.

have inspected the components described in this Owners Report during the period of 12/20/99 to 12/21/99

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss

of any kind arising from or connected with this inspection.

AJ 7,5 • a4 4 X Commissions N97244'l'rL3aM

Inspector's Signature National Board. State. Providence. and Endorsements

Date Z(l Z 0 - c'

N/A

r•

ogn•

Page 16: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

a

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Name

700 Universe Blvd. Juno Beach, FL 33408

Address

Turkey Point Plant Name

9760 SW 344 Street Florida City, FL 33035

Date

Sheet

Unit

I(7/OO

of 2

4

WO#: 29020580 CR#: N/A

Florida Power & LightName

9760 SW 344 Street Florida City, FL 33035

4. Identification of System:

Addrem

Component Cooling Water

Re

Type Code Symbol

Authorization Numb4

Expiration Date

System #: 30 Quality Group

pair Organization, P.O. No. Job No.. ac.

Stamp N/A

or N/A

N/A

C

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements

19 55 Edition,

1989 Edition,

N/A Addenda,

N/A Addenda,

N/A Code Case

N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

7. Description of Work:

REPLACED BOLTING ON INLET HEAD COVER; (36) STUDS AND (72) NUTS.

, Tests Conducted: Hydrostatic: t4 11

Other

Pneumatic 10 W

Pressure N IL psig

Nominal Operating Pressure

Test Temperature I& deg F

Owner

2. Plant

3. Work Performed by

ASME Repaired, Code

Name of Name of Manufacturer National Other Year Replaced, or Stamp Component Manufacturer Serial Number Board Identification Built Replacememt Yes/No

ROD THREADED, N/A N/A N/A STK CODE 0029493-1 N/A REPLACEMENT N (36) STUDS FABRICATED, ASME UTC U 428803 SA-193, GR B7

NUT, HEAVY HEX, N/A N/A N/A STK CODE 0027837 N/A REPLACEMENT N (72), ASTM A-194, UTC #428761 GR. 7

4- I £ L I ___ ± _________ I _____

00-001-4

Page 17: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2FORM NIS-2 (Back)

4. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No.

Signed

e~ow- ý wi

N/A

ner or Owner's Designee, Title

Expiration Date: N/A

Date " J

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state or Province of Dade County and employed by Factory Mutual Insurance Company of Norwood, Me. have inspected the components described in this Owners Report during the period of 11/9/99 to 1/7/00 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neithe the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions ,JA 7 7/ 1 National Board, State, Providence, and Endorsements

Date 9 1 --- 2& - VV

Inspector's Signature

00-001-4

_,-Z - I- "N/A

L -

Page 18: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

700 Un

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Date 4/13/ Name

iverse Blvd. Juno Beach, FL 33408 Sheet

Addrese

Turkey Point Plant Unit

Nasf.

9760 SW 344 Street Florida City, FL 33035Address

3. Work Performed by Florida Power & Light Name

9760 SW 344 Street Florida City, FL 33035

T

A

Address

4. Identification of System: Auxiliary Feedwater System #: 75

5. (a) Applicable Construction Code B31.1 1

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1

6. Identification of Components Repaired or Replaced and Replacement Components

00

2of

4

)wner

2. Plant

7. Description of Work:

REPLACED THE EXISTING 1/2" DIAMETER BOLT JOINING THE 3" PIPE CLAMP TO SUPPORT 4-AFX-8 WITH A 3/4" DIAMETER HEX HEAD BOLT AND DOUBLE NUT.

3. Tests Conducted: Hydrostatic: N/A

Other VT-3

Pneumatic N/A

Pressure N/A psig

Nominal Operating Pressure N/A

Test Temperature N/A deg F

00-002-4

WO#: 29011425 01 CR#: N/A

Repair Organization. P.O. No, Job No., etc.

ype Code Symbol Stamp N/A

,uthorization Number N/A

Expiration Date N/A

Quality Group B

9 55 Edition, N/A Addenda, N/A Code Case

9 89 Edition, N/A Addenda, N/A Code Case

ASME Repaired. Code

Name of Name of Manufacturer National Other Year Replaced, or Stamp Component Manufacturer Serial Number Board Identification Built Replacememt Yes/No

(1) SCREW, CAP, N/A N/A N/A STK CODE 27122 1 UNK REPLACEMENT N HEAVEY HEX, 3/4 UTC 424688 TRCE HCR63749 ",ASME SA-193 GR B7

(2) NUT, HEAVY N/A N/A N/A STK CODE 27930 1 UNK REPLACEMENT N HEX, 3/4"-10,ASTM UTC 418461 TRCE H8098740 A-563 GR B

Page 19: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have

inspected the components described in this Owners Report during the period of 1 2/3/99 to 4/13/00

and state that to the best of my knowledge and belief, the Owner has performed examninations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss

of any kind arising from or connected with this inspection.

ctor', Signature

Commissions /4/; k-' > National Board, State, Providence, and Endorsements

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of

the ASME Code, Section Xl.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A Expiration Date: N/A

S Ow or O er's Designee. Title

00-002-4

Page 20: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

Owner

2. Plant

3. Work Performe

4. Identification of System:

Florida Power & Light

Name

700 Universe Blvd. Juno Beach, FL 33408

Address

Turkey Point Plant Name

9760 SW 344 Street Florida City, FL 33035

Address

Florida Power & LightName

9760 SW 344 Street Florida City, FL 33035Address

Intake Cooling Water

Date

Sheet

Unit

4/27/00

of 2

4

WO#: 30007432 01 CR#: N/A

Repair Organizabon, P.O. No, Job No.. etc.

Type Code Symbol Stamp N/A

Authorization Number N/A

Expiration Date N/A

System #: 19 Quality Group C

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements

19 55 Edition,

1989 Edition,

N/A Addenda,

N/A Addenda,

N/A Code Case

N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Manufacturer National Other Year Replaced, or Stamp

Component Manufacturer Serial Number Board Identification Built Replacememt Yes/No

8" GATE VALVE, CRANE N7W30 N/A STK CODE 52836 2 UNK REPLACEMENT N

CAST IRON,ASTM A- UTC 410052 126

ROD, THREADED, N/A N/A N/A STK CODE 29493 1 UNK REPLACEMENT N

16 STUDS UTC 431593 FABRICATED,A-36

(32) NUTS, ASTM A- N/A N/A N/A STK CODE 27837 1 UNK REPLACEMENT N

194 GR 7, HEAVY UTC 431033

7. Description of Work:

REPLACED VALVE,ý-50-326 WITH NEW VALVE, ALSO REPLACED (16) STUDS AND (32) NUTS. e•r 0119,-1

8. Tests Conducted: Hydrostatic: Pneumatic Nominal Operating Pressure

Pressure 14.5 psig Test Temperature 87 deg FOther VT-2

X

00-003-4

V•U IJV

Page 21: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of

the ASME Code, Section XI.

Type Code Symbol Stamp

Certificatedization No.

i

N/A

N/A Expiration Date: N/A

Date W171 0'O/her or Owner's Designee, Title

L�

00-003-4

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have

inspected the components described in this Owners Report during the period of 4/17/00 to 4/27/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss

of any kind arising from or connected with this inspection.

Commissions t v idne 1 nd Endrseent National Board, State. Providence, and Endorsements

or's Signature

Date ci"2- U /I

N/A

Page 22: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Owner

2. Plant

700 Un

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Date Name

iverse Blvd. Juno Beach, FL 33408 Sheet "Addrme

Turkey Point Plant UnitNam

9760 SW 344 Street Florida City, FL 33035WOO: 2900988

6/13/00

of 2

4

801 CR#: 99-0697

Address Repair Organization, P.O. No, Job No., etc.

3. Work Performed by Florida Power & Light Type Code Symbol Stamp N/A Name

Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035

"eExpiration Date N/A

4. Identification of System: Intake Cooling Water System #: 19 Quality Group C

5. (a) Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacement* 1989 Edition, N/A Addenda, N41.6-1 Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Mfg Mfg Sedal National Other Year Replaced, or Stamp Component Number Board Identification Built Replacememt Yes/No

ROD, THREADED, (8) STUDS N/A N/A N/A STK CODE 29493 1 UNK REPLACEMENT N FABRICATED SA-193 GR B7 UTC 430115

(8) NUTHEAVY HEX, C.S. NIA N/A N/A STK CODE 27084 1 UNK REPLACEMENT N SA-194 UTC 428805

PIPE,C.S., 55" USED, SA- N/A N/A N/A STK CODE 30637 1 UNK REPLACEMENT N

106, GR B SCH. 40 UTC 431874

ELBOW, 90 DEGREE, 4%, N/A N/A N/A STK CODE 33893 1 UNK REPLACEMENT N SCHED. 40, SA-234 UTC 429994

ELBOW, 90 DEGREE, 4", N/A N/A N/A STK CODE 33893 1 UNK REPLACEMENT N SCHED. 40, SA-234 UTC 429995

7. Description of Work:

REPLACED VALVE 4-50-413 AND ASSOCIATED VENT LINE. ALL WORK ASSOCIATED WITH WO# 29009888 01 IS DOCUMENTED UNDER NIS-2 00-004-4 AND NIS-2 00-005-4.

8. Tests Conducted: Hydrostatic:

Other VT-2

Pneumatic

Pressure 4 psig

Nominal Operating Pressure X

Test Temperature 85 deg F

00-004-4

Page 23: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks ALL WELDING PERF6RMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUAL. CODE CASE N-416.1 WAS

INVOKED FOR THIS REPLACEMENT ACTIVITY.

00-004-4

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have

inspected the components described in this Owners Report during the period of 11/17/99 to 6/13/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss

of any kind arising from or connected with this inspection.

Commissions

Inspector's Signature National Board, State, Providence, and Endorsements

Date __ _ _ _ _ _ _

Page 24: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

")w ner

2. Plant

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Proviaiono of the ASME Code Section XI

Florida Power & Light Date Name

700 Universe Btvd. Juno Beech, FL 33408 Sheet

Addre•s

Turkev Point Plant Unit

Name

9760 SW 344 Street Florida City, FL 33035

WOO: 2900988

6/13/00

of 2

4

801 CR#: 99-0697

Address Repair Organization. P.O. No, Job Nf. etc.

3. Work Performed by Florida Power & Light Type Code Symbol Stamp N/A Name Authorization Number N/A

9760 SW 344 Street Florida City, FL 33035 Addos Expiration Date N/A

4. Identification of System: Intake Cooling Water System #: 19 Quality Group C

5. (s) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case

lb) Applicable Edition of Section Xl Utilized for Repairs or Replascement. 1989 Edition, N/A Addenda, N41 6-1 Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Mfg Mfg Serial Nationd Other Year Replaced, or Stamp

Component Number Board Identification Built Replacememt Yes/No

PIPE,C.S. 4" USED,SA-1O6 N/A N/A N/A STK CODE 30618 1 UNK REPLACEMENT N GR B SCHED. 40 UTC 408446

3/4 CAP, SA 105, C.S. N/A N/A N/A STK CODE 33565 1 UNK REPLACEMENT N

UTC 410324

HALF COUPLIN, C.S.SA-105 N/A N/A N/A STK CODE 33963 1 UNK REPLACEMENT N

UTC 373908

FLANGE, C.S. SA-105 N/A N/A N/A STK CODE 34080 1 UNK REPLACEMENT N

UTC 378035

3/4" GLOBE VALVE, MODEL EDWARDS N/A N/A STK CODE52980 1 UNK REPLACEMENT N

A848YT2 UTC 416498

7. Description of Work:

REPLACED VALVE 4-50-413 AND ASSOCIATED VENT UNE. ALL WORK ASSOCIATED WITH WO# 29009888 01 IS DOCUMENTED UNDER NIS-2 00-004-4 AND NIS-2 00-005-4.

8. Tests Conducted: Hydrostatic:

Other VT-2

Pneumatic

Pressure 4 psig

Nominal Operating Pressure X

Test Temperature 85 deg F

00-005-4

Page 25: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUAL. CODE CASE N-416.1 WAS

INVOKED FOR THIS REPLACEMENT ACTIVITY.

00-005-4

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of

the ASME Code, Section XI.

e .... e.., . N/A

N/ACertificate of Auhorization No. N/A Expiration Date:

31U[IUJ /~ Dotbvnoror Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have

inspected the components described in this Owners Report during the period of 11/17199 to 6/13/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss

of any kind aria g from or connected with this inspection.

______ ______ _____Commissions Me6 702ý 'R5~

Inspector's Signature National Board. State. Providence, and Endorsements

Date //

I

I ype %,008 rvw -1-

Page 26: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Date Name

700 Universe Blvd. Juno Beach, FL 33408 Sheet Address

Turkey Point Plant Uniteow

9760 SW 344 Street Florida City, FL 33035Address

3. Work Performed by Florida Power & Light Nome

9760 SW 344 Street Florida City, FL 33035

4. Identification of System:

Address

Component Cooling Water

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section XI Utilized for Repairs or Replae

7/24/00

of 2

4

1. Owner

2. Plant

Repair Organhzratm, P.O. No, Job No., etc.

Type Code Symbol Stamp NIA

Authorization Number N/A

Expiration Date N/A

System #: 30 Quality Group C

19 55 Edition, N/A Addenda, N/A Code Case

cements 1989 Edition, N/A Addenda, N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Mfg Mfg Serial National Other Year Replaced, or Stamp Component Number Board Identification Built Replscememt Yes/No

ROD, THREADED (1 STUD N/A N/A N/A STK CODE 29493 1 UNK REPLACEMENT N FABRICATED) ASME SA-193 UTC 431734 GR B7

NUT (2), ASTM A-194 GR 7 N/A N/A N/A STK CODE 27837 1 UNK REPLACEMENT N HEAVY HEX UTC 428761

7. Description of Work:

REPLACED (1) STUD AND (2) NUTS

8. Tests Conducted: Hydrostatic: N/A

Other N/A

Pneumatic N/A

Pressure N/A psig

Nominal Operating Pressure N/A

Test Temperature N/A deg F

00-006-4

WO#: 29020678 01 CR0: 99-1485

Page 27: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of

the ASME Code, Section XI.

NIAType Code Symbol Stamp

N/A Expiration Date: N/A

V Datea 1 /6k"A " - -Owner or Owner's Designee, Title

LY�LI

Certificate 1 ,Authorization No.

00-006-4

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have

inspected the components described in this Owners Report during the period of 5/31/00 to 7/24/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss

of any kind arising from or connected with this inspection.

Commissions ' 1ze- 5 F6- •z8 National Board, State, Providence, and Endorsements

Itpe tors Signature

Date e') 06 z C70

N/AS....

| -| -I - -b,•yw

Page 28: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Date

Name

700 Universe Blvd. Juno Beach, FL 33408 Sheet

Turkey Point Plant UnitNamte

9760 SW 344 Street Florida City, FL 33035

1. Owner

2. Plant

7/25/00

of 2

4

501 CR#: N/A

Adm

3. Work Performed by Florida Power & Light Nam

9760 SW 344 Street Florida City, FL 33035

T A

4. Identification of System: Component Cooling Water System #: 30

5. (a) Applicable Construction Code B31.1 1

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacement* 1|

6. Identification of Components Repaired or Replaced and Replacement Components

Repair Organization, P.O. No, Job No., dc.

ype Code Symbol Stamp N/A

uthorization Number N/A

xpiration Date N/A

Quality Group C

9 55 Edition, N/A Addenda, N/A Code Case

89 Edition, N/A Addenda, N/A Code Case

ASME Repaired, Code

Name of Name of Mfg Mfg S0e6l National Other Year Replaced, or Stamp

Component Number Board Identification Built Replacememt Yes/No

NUT (2), 3/4', ASTM A-194 N/A N/A N/A STK CODE 27837 1 UNK REPLACEMENT N

GR 7 UTC 423130

+ + + + I I

-4 I T1

I I I I t t

7. Description of Work:

REPLACED (2) ERODED NUTS AT MANWAY ON THE 48 COMPONENT COOLING WATER HEAT EXCHANGER.

8. Tests Conducted: Hydrostatic: N/A

Other N/A

Pneumatic N/A

Pressure N/A psig

Nominal Operating Pressure N/A

Test Temperature N/A deg F

00-007-4

WOO: 3000919

Page 29: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI.

N/AType Code Symbol Stamp

NExpiration Date: N/ACertificate ation No.

e=uthonz

�g; IIG/2Owner or Owner's Designee, Title

S on

Date 0OO

00-007-4

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Bo4ler and Pressure Vessel Inspectors

and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have inspected the components described in this Owners Report during the period of 5/15/00 to 7/25/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss

of any kind arising from or connected with this inspection.

/,ý n o eý?_Commissions A6I'7,2ý( rls'2,eNational Board. State, Providence, and Endorsements

"I ns$ector's Signature

Date ______9____

66 116W N/A

N/A

Page 30: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

Florida Power & LightNaie

700 Universe Blvd. Juno Beach, FL 33408Add*e

Turkey Point Plant

Date

Sheet

Unit

NeMwe

9760 SW 344 Street Florida City, FL 33035

3. Work Performed by

Adrem

Florida Power & Light Nao

9760 SW 344 Street Florida City, FL 33035

4. Identification of System:

Address

Component Cooling Water

8/21/00

1 of 2

4

WO#: 30009032 CR#: N/A

Type Code Svmb4

Authorization Number

Expiration Date

System #: 30 Quality Group

Rela*r Organizatloe. P.O. Noe. Je f.. ,te.

o1 Stamp N/A

N/A

N/A

C

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements

19 55 Edition. N/A

1989 Edition, NIA

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired. Code

Name of Name of Mfg Mfg Serial National Other Year Replaced, or Stamp

Component Number Board Identification Built Replacememt Yes/No

(1) NUT, ASTM A-194 GR 7, N/A N/A N/A STK CODE 27837 1 UNK REPLACEMENT N HEAVY HEX UTC 431033

7. Description of Work:

REPLACED ONE MISSING N`IT AT MANWAY ON THE 4A COMPONENT COOLING WATER HEAT EXCHANGER

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure

N/A . Pressure N/A psig Test Temperature N/A deg F

)wner

2. Plant

Addends,

Addenda,

N/A

N/A

Code Case

Code Case

Other

N/A

00-008-4

Page 31: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION. NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI.

TypeCodeSymol SampN/A

Expiration Date: N/ACertificate of Authorization No.

Owner or Owner's Designee, TitleSigned

-) � AA4�

Sheet 2 of 2

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have inspected the components described in this Owners Report during the period of 5/12/00 to 8/21/00 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ionature Commissions l ,St/s Pvi -ad E / / nspcto's SgnaureNational Board. State. Providence, and Endorsements

Date /0/ 6vI

00-008-4

Type Code Symbol Stamp

N/A

Dat.C,. 2

r W

Page 32: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Owner

2. Plant

700 Un

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Date 10/5/00 Name

iverse Blvd. Juno Beach, FL 33408 Sheet 1 of 2 AddTreo

Turkey Point Plant _____Unit 4Nom

9760 SW 344 Street Florida City, FL 33035WOO: 98014334 01 CR#: 95-240

Address Rspar Organlzaie., P.O. No. Job No. etc.

3. Work Performed by Florida Power & Light Type Code Symbol Stamp N/A Name

Authorization Number N/A 9760 SW 344 Street Florida City, FL 33035 "dress Expiration Date N/A

4. Identification of System: Intake Cooling Water System #: 19 Quality Group C

5. (a) Applicable Construction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 19 89 Edition, N/A Addenda, N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Mfg Mfg Seral National Other Year Replaced, or Stamp Component Number Board Identification Built Replacememt Yes/No

PUMP 4P9C JOHNSTON N/A N/A 4P9C (IST-3) UNK REPLACED N

PUMP 4P9C JOHNSTON N/A N/A 4P9C (IST-8) UNK REPLACEMENT N

ROD, THREADED, 20 STUDS N/A N/A N/A STK CODE 29507 1 UNK REPLACEMENT N FABRICATED ASTM A193 GR UTC 426373 B7

NUT HEAVY HEX (20) ASTM N/A N/A N/A STK CODE 27861 UNK REPLACEMENT N A-194 GR 7 UTC 433078

7. Description of Work:

REPLACED 4C ICW PUMP (IST-3) WITH SPARE PUMP (IST-8). ALSO REPLACED (20) STUDS AND (40) NUTS.

8. Tests Conducted: Hydrostatic: X

Other VT-2

Pneumatic

Pressure 18.5 psig

Nominal Operating Pressure

Test Temperature 91 deg F

00-009-4

Page 33: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report awe correct and this replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A

Certificate of Authorization No.

A,

C>

N/A Expiration Date: N/A

- DateOwner or Owner's Designee, Title

'-'- ()

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have inspected the components described in this Owners Report during the period of 4/8/99 to 10/5/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of- ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any k ringfom or connected with this inspection.

__ __ __ __ _ __ __ __ _Commissions Al jjý 1K& 328

National Board, State, Providence, and EndorsementsU Inspector's Signature

Date /1//~

00-009-4

Page 34: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Owwner

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

As Required by the Provisions of the ASME Code Section Xl

Florida Power & Light Date Name

700 Universe Blvd. Juno Beach, FL 33408 Sheet

AddsnmU

Tu~rks~ Point Plant Unit

Name

9760 SW 344 Street Florida City, FL 33035 Address

3. Work Performed by Rorida Power & Light

Name

9760 SW 344 Street Florida City, FL 33035

WO#: 9801433

T•

A E

Address

4. Identification of System: Intake Cooling Water System #: 19

S. (a) Applicable Construction Code B31.1 1

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1

6. Identification of Components Repaired or Replaced and Replacement Components

10/5/00

of 2

4

2 01 CR#: 95-240

Rei"l Organizabon, P.O. No. Job No., etc.

ype Code Symbol Stamp N/A

uthorization Number N/A

xpiration Date N/A

Quality Group C

955 Edition, N/A Addenda ....... N/A.. Code Case

9 89 Edition, N/A .Addenda, . ........ N......Code Case

ASME Repaired, Code

Name of Name of Mfg Mfg Seral National Other Year Replaced, or Stamp

Component Number Board Identification Built Replaoememt Yes/No

EXPANSION JOINT N/A N/A NIA STK CODE 14195 1 UNK REPLACEMENT N

UTC 433031

STUD (20), ASTM A193 B7 N/A N/A N/A STK CODE UNK REPLACEMENT N

UTC 428941

NUT HEAVY HEX (20), N/A N/A N/A STK CODE 27861 1 UNK REPLACEMENT N

ASTM A-194 GR 7 UTC 433078

7. Description of Work:

REPLACED EXPANSION JOINT, (20) STUDS AND (20) NUTS.

8. Tests Conducted: Hydrostatic: X

Other VT-2

Pneumatic

Pressure 18.5 psig

Nominal Operating Pressure

Test Temperature 91 deg F

00-010-4

' PI nt 7u• y • v... . .

Page 35: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI.

N/AType Code Symbol Stamp

-Expiration Date: N/A

Date ,013 ciiSigned1- . V-Owner or Owner's Designee, Title

Certificate of Authorization No.

00-010-4

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have inspected the components described in this Owners Report during the period of 4/8/99 to 10/5/00 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

a .... Commissions / 7 , Signature National Board. State, Providence, and Endorsements

Date 1/6 Z/lo

N/A

Page 36: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

As Required by the Provisions of the ASME Code Section XI

:wner Florida Power & Light Name

700 Universe Blvd. Juno Beach, FL 33408

Date

Sheet

Address

2. Plant Turkey Point Plant Unit

Nam WOS: 30C

9760 SW 344 Street Florida City, FL 33035 Address Rf

3. Work Performed by Rorida Power & Light Type Code Symbol NOAe

Authorization Numni 9760 SW 344 Street Florida City, FL 33035

4sresia HExpiration Date

4. Identification of System: Residual Heat Removal System #: 50 Quality Group

10/13/00

of 2

4

11717201 CR#: 00-1576

spalr Organdzatlon. P.O. No, Job No., etc.

St-n N/A

er N/AN/A

a _____

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section X1 Utilized for Repairs or Replacements

1955 Edition, N/A Addenda,

19 89 Edition. N/A Addenda,

N/A Code Case

N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Mfg Mfg Serial National Other Year Replaced, or Stamp

Component Number Board Identification Built Replacememt Yes/No

ROD,THREADED (8) STUDS N/A N/A N/A STK CODE 29490 1 UNK REPLACEMENT N

FABRICATED,ASME SA 193 UTC 430227 GR B7

NUT (16), ASTM A-194 GR N/A N/A N/A STK CODE 27836 1 UNK REPLACEMENT N

2H HEAVY HEX UTC 424347

7. Description of Work:

REPLACED (8) STUDS AND (16) NUTS.

8. Tests Conducted: Hydrostatic: N/A

Other VT-I

Pneumatic N/A

Pressure N/A psig

Nominal Operating Pressure N/A

Test Temperature N/A deg F

00-011-4

1

Page 37: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

00-011-4

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI.

Type Ccde Symbol Stamp N/A

N/ACertificate

Date o(0 C-Signed

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have

inspected the components described in this Owners Report during the period of 10/3/00 to 10/13/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a lose

of any kind arising from or connected with this inspection.

SCommissions PC Inspector's Signature National Board, State, Providence, and Endorsements

Date

Page 38: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

As Required by the Provisions of the ASME Code Section XI

Rorida Power & Light

Name

700 Universe Blvd. Juno Beach, FL 33408

Address

Turkey Point Plant Name

9760 SW 344 Street Florida City, FL 33035Address

3. Work Performed by Florida Power & Light Name

9760 SW 344 Street Florida City, FL 33036 Address

Date

Sheet

Unit

10/18/00

1 of 2

4

WO#: 29009939 01 CR#: 99-0056

Repair Organization. P.O. No, Job No.. tc.

Type Code Symbol Stamp N/A

Authorization Number N/A

Expiration Date N/A

4. Identification of System: Intake Cooling Water System #: 19 Quality Group C

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements

19 55 Edition,

19 89 Edition,

N/A Addenda, N/A Code Case

N/A Addenda, N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Mfg Mfg Serial National Other Year Replaced, or Stamp

Component Number Board Identification Built Replacememt Yes/No

VALVE (1), 36" BUTTERFLY N/A N/A N/A STK CODE 52333 2 UNK REPLACEMENT N

UTC 325416

NUT, (10) HEAVY HEX, N/A N/A N/A STK CODE 27865 1 UNK REPLACEMENT N

ASTM A 194 GR 2H UTC 434721

STUD (2), ASTM A193, GR N/A N/A N/A STK CODE 28044 1 UNK REPLACEMENT N

B7 UTC 416373

STUD (6), ASTM A193, GR N/A NIA N/A STK CODE 28044 1 UNK REPLACEMENT N

B7 UTC 432745

7. Description of Work:

REPLACE VALVE 4-50-310, (10) NUTS & (8) STUDS

8. Tests Conducted: Hydrostatic: N/A Pneumatic NIA Nominal Operating Pressure

Pressure N/A psig Test Temperature N/A deg F

)wner

2. Plant

Other N/A

N/A

00-013-4

Page 39: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2FORM NIS-2 (Back)

9. Renarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report wre correct and this replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate ofthorization No.

i-- A f (1 14L/

N/A

Owner or Owner's Designee, Title

Expiration Date: N/A

Date 2d {1o

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have inspected the components described in this Owners Report during the period of 5/15/00 to 10/16/00 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

10a-Comm~issions I < /~~~National Board, State, Providence, and Endorsements"Inspector's Signature

Date /I/ I.I /

00-013-4

Page 40: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Date Name

700 Universe Blvd. Juno Beach, FL 33408 Sheet

Address

Turkey Point Plant'� Ph�nt

Name

9760 SW 344 Street Florida City, FL 33035

Address

3. Work Performed by Florida Power & Light Namn

9760 SW 344 Street Florida City, FL 33035 Address

4. Identification of System: Supports and Hangers

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section X1 Utilized for Repairs or Replac

Unit 4

WO#: 30011986 01 CR#: N/A

Repair Organization, P.O. No, Job No., etc.

Type Code Symbol Stamp N/A

Authorization Number N/A

Expiration Date N/A

System #: 105 Quality Group A

19 55 Edition, N/A Addenda, N/A, Code Case

cements 1989 Edition, N/A Addenda, N/A . Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

Name of Comoonent

Name of Mfg Mfg Serial Number

Component___________I-I

SNUBBER 4-1051 PSA 10

SNUBBER 4-1051 PSA 10

SNUBBER 4-1053 PSA 10

SNUBBER 4-1053 PSA 10

PSA

PSA

PSA

11125

17904

11446

National Board

N/A

N/A

N/A

Other Identification

N/A

N/A

N/A

NIA

N/A

- 4- -I- + 1

PSA 16245

________________________________ 1 ______________1 _________ I

N/A N/A

N/A

ASME Repaired, Code

Year Replaced, or Stamp Built Replacememt Yes/No

UNK REPLACED N

UNK REPLACEMENT N

LINK REPLACED N

LINK REPLACEMENT N

7. Description of Work:

REPLACED (2) PRESSUREIZER SNUBBERS - REPLACED 4-1051 SIN 11125 WITH SIN 17904 - REPLACED 4-1053 S/N 11446 WITH

S/N 16245.

8. Tests Conducted: Hydrostatic: N/A

Other N/A

Pneumatic N/A

Pressure N/A psig

Nominal Operating Pressure N/A

Test Temperature N/A deg F

00-014-4

,. Owner10/15100

of

Page 41: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A Ex

C; 14 Jjý -,AAWPW'-Owner or Owner's Designee, Title

piration Date: N/A

___Date - 0 t 00

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by Factory Mutual Insurance Company of Johnston. Rhode Island, have inspected the components described in this Owners Report during the period of 6/16/00 to 10/15/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State. Providence, and Endorsements

Date

00-014-4

N/Agne

-" - i)

Page 42: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

Florida Power & LightName

700 Universe Blvd. Juno Beach, FL 33408

Address

Turkey Point Plant

Name

9760 SW 344 Street Florida City, FL 33035

Address

Date

Sheet

U nit

10/15/00

1 of 2

4

WO#: 30011986 01 CR#: N/A

Repair organization. P.O. No, Job No., etc.

3. Work Performed by Florida Power & Light Name

9760 SW 344 Street Florida City, FL 33035Address

Type Code Symbol Stamp

Authorization Number

Expiration Date

-4. Identification of System: Supports and Hangers System #: 105 Quality Group

5. (a) Applicable Construction Code B31.1 1955 Edition,

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Edition,

6. Identification of Components Repaired or Replaced and Replacement Components

N/A Addenda,

N/A Addenda,

N/A Code Case

N/A Code Case

T r r I 7 7

Name ot Component

SNUBBER 4-1057 PSA 3

SNUBBER 4-1057 PSA 3

Name of Mfg Mfg Serial Number

National Board

Other Identification

Year Built

-4 4 1

PSA 27080 N/A N/A

N/A

N/A

t _ _ _ i I

PSA 27092 N/A N/A

N/A

N/A

-I 4- 1- t T

I -� 4- 4 1 t

F -� 1

I I I__ _ I

Repaired, Replaced, or Replacememt

REPLACED

REPLACEMENT

I

7. Description of Work:

REPLACED ONE (1) PRESSURIZER SNUBBER - REPLACED 4-1057 S/N 27080 WITH SIN 27092.

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure

Pressure N/A psig Test Temperature

1. Owner

2. Plant

N/A

N/A

N/A

A

ASME Code

Stamp Yes/No

N

N

Other N/A

N/A

N/A deg F

00-015-4

Page 43: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks MECHANICAL CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct end this replaced component conforms to the

rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate outhorization No. N/A

Sinned A

Expiration Date: N/A

Dateo7 0Owner or Ovi/ner's Designee, Title

C*(J

00-015-4

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have

inspected the components described in this Owners Report during the period of 6/16/00 to 10/15/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss

of any kind arising from or connected with this inspection.

'~~ect or~~at u Commissions IA Y & ?c pector's Signature National Board. State. Providence, and Endorsements

Date

NIA

SU_

Page 44: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

As Required by the Provisions of the ASME Code Section Xl

Florida Power & Light Date Name

700 Universe Blvd. Juno Beach, FL 33408 Sheet Addrmm

Turkev Point Plant Unit

Nam

9760 SW 344 Street Florida City, FL 33035

10/18/00

of

4

2

WO#: 30018818 01 CRXU: N/A

"Addrnes Repa4r Orgflhzan",tio P.O. No, Job No., eo.

3. Work Performed by Florida Power & Light Type-Code Symbol Stamp N/A

Na Authorization Number N/A

9760 SW 344 Street Florida City, FL 33035 Expiration Date N/A Address

4. Identification of System: Reactor Coolant System #: 41 Quality Group A

5. (a) Applicable Construction Code B31.1 1955 Edition ........ N./A .Addenda, ......N/A...... Code Case

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 Edition, ........ Addenda ...... N/A .. Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME

Repaired, Code

Name of Name of Mfg Mfg Serial National Other Year Replaced, or Stamp

Component Number Board Identification Built Replacememt Yes/No

NUT.(12) HEAVY HEX C.S. N/A N/A N/A STK CODE 27084 1 UNK REPLACEMENT N

ASME SA-194 GR 2H UTC 428805

ROD,THREADED (12) STUDS N/A N/A N/A STK CODE 29493 1 UNK REPLACEMENT N

FABRICATED ASME SA-193 UTC 434126 GR B7

7. Description of Work:

OVERHAULED VALVE MOV-4-535, REPLACED (12). STUDS AND (12) NUTS.

8. Tests Conducted: Hydrostatic: N/A

Other N/A

Pneumatic N/A

Pressure NIA psig

Nominal Operating Pressure N/A

Test Temperature N/A deg F

00-017-4

'wner

2. Plant

Page 45: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp NIA

Certificate of uthorization No. N/A E

Signed__ _ ~Owner or Owner's Clesgnee, Title

xpiration Date: N/A

Date ' -b

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have inspected the components described in this Owners Report during the period of 10/16/00 to 10/18/00 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code. Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any ki rising from or connected with this inspection.

cL o ew t ic• Commissions !•'\V- (.National Board, State, Providence, and EndorsementsInspector

Date

's Signature

Sheet 2 of 2

00-017-4

N/A

0ýd-

Page 46: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provialiona of the ASME Code Section Xl

DateFlorida Power & Light Name

700 Universe Blvd. Juno Beach, FL 33408 Addres

Turkey Point Plant Nor"

9760 SW 344 Street Florida City, FL 33035 Address

Sheet

Unit

10/18/00

1 of 2

4

WOO: 29011641 01 CR#: 99-0813

Repair Organization. P.O. No, Job No., etc.

3. Work Performed by Florida Power & Light Name

9760 SW 344 Street Florida City, FL 33035

4. Identification of System:

Address

SPENT FUEL HANDLING

Type Code Symbol Stamp N/A

Authorization Number N/A

Expiration Date N/A

System *: 38 Quality Group MC

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacement@

19 55 Edition,

1992 Edition,

N/A

92

Addenda,

Addenda,

N/A Code Case

N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Mfg Mfg Serial National Other Year Replaced, or Stamp

Component Number Board Identification Built Replacememt Yes/No

BLIND FLANGE. DOUBLE N/A N/A N/A STK 0236100 2 UNK REPLACEMENT N

GROOVE ASME SA-182 GR UTC 0000434616 F304

7. Description of Work:

REPLACE BLIND FLANGE SPENT FUEL CANAL

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure

Other APP.J TYPE B Pressure N/A psig Test Temperature N/A deg F

'wner

2. Plant

N/A

00-018-4

Page 47: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report we correct and this replacement conforms to the rules of

the ASME Code, Section XI.

N/AType Code Symbol Stamp

Expiration Date: N/A

Date j(1710

Certificate of Authorization No. N/A

Siu nou51- AAf

Owner or Owner's Designee, Title

00-018-4

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have

inspected the components described in this Owners Report during the period of 8/29/00 to 10/18/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss

of any kind arising from or connected with this inspection.

_Commissions

n ctor's Signature National Board, State, Providence, and Endorsements

Date

NIAV

Page 48: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

As Required by the Provisions of the ASME Code Section XI

Date

Sheet

Unit

Florida Power & Light Name

700 Universe Blvd. Juno Beach, FL 33408 Address

Turkey Point Plant Name

9760 SW 344 Street Florida City, FL 33035Address

3. Work Performed by Florida Power & Light Name

9760 SW 344 Street Florida City, FL 33035

10/23/00

1 of 2

4

WO#: 29010612 01 CR#: 99-0690

Repair Organization, P.O. No, Job No., etc.

&l1A

Type Code Symbol Stamp,

Authorization Number

Fvminr tin n fl.*at

Addres6

4. Identification of System: Safety Injection - Systemn #: 62 Quality Group.

N/A

N/A

A

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements

1955 Edition, N/A

1989 Edition, N/A

Addenda, N/A Code Case

Addenda, N-41 6-1 Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Mfg Mfg Seral National Other Year Replaced, or Stamp

Component Number Board Identification Built Replacememt Yes/No

VALVE (1), 2" PISTON CHECK EDWARDS N/A N/A STK CODE 30938 01 UNK REPLACEMENT N VALVES,INC

UTC 420971

7. Description of Work:

REPLACED VALVE 4-873A

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure

Other VT-2 Pressure 2280 psig Test Temperature 547 deg F

Owner

2. Plant

X

00-019-4

I•11 PI,

Page 49: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

00-019-4

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

N/AType Code Symbol Stamp

Expiration Date: N/ACertificate of Authorization No.

"C: A 11k,. 4, 5~~u~ Date CCOwner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by Factory Mutual Insurance Company of Johnston. Rhode Island, have inspected the components described in this Owners Report during the period of 5/20/00 to 10/23/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions A/7l" .32National Board, State, Providence, and Endorsements

Inspector's Signature

DateI

N/A

r

5ýr- k6i e-tin

W.•VA/ - 0I

Page 50: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMEN iS As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Name

700 Universe Blvd. Juno Beach, FL 33408 Addres

Turkey Point Plant Name

9760 SW 344 Street Florida City, FL 33035

Date

Sheet

Unit

10123/00

I of 2

4

WOO: 30017904 01 CR#: N/A

Address

3. Work Performed by Florida Power & Light Name

9760 SW 344 Street Florida City, FL 33035

4. Identification of System: Component Cooling Water System #: 30

Repair Organization, P.O. No. Job to.., ab.

Type Code Symbol Stamp N/A

Authorization Number N/A

Expiration Date N/A

Quality Group C

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements

1955 Edition,

19 89 Edition.

N/A Addenda,

NIA Addenda,

NIA Code Case

N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Mfg Mfg Serial National Other Year Replaced, or Stamp

Component Number Bord Identification Built Replacememt Yes/No

RELIEF VALVE,SET DRESSER TK-97939 N/A STK CODE 53486 1 UNK REPLACEMENT N

PRESSURE 150 PSIG UTC 407563

7. Description of Work:

REPLACED RELIEF VALVE RV-4-1431

8. Tests Conducted: Hydrostatic: X Pneumatic N/A Nominal Operating Pressure

Pressure 84 psig Test Temperature 77 deg F

Owner

2. Plant

Other VT-2

N/A

00-020-4

Page 51: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report wre correct and this replacement conforms to the nAue of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No.

C; - u, ,gnSS

N/A Expiration Date: N/A

Date Lt/lo"" .. . Owner or Owner's Designee. Title

CERTIFICATE OF INSERVICE INSPECTION

I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have inspected the components described in this Owners Report during the period of 10/1/00 to 10/23/00 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions aector's Signature National Board, State, Providence, and Endorsemnrits

Date /0/71

00-020-4

Page 52: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provilione of the ASME Code Section X)

Florida Power & Ught Mem.

700 Universe Blvd. Juno Beach, FL 33408

Turkey Point Plant 9m4

9760 SW 344 Street Florida City, FL 33031

3. Work Performed by

Adm

Florida Power & Ught

9760 SW 344 Street Florida City, Fl. 33031

4. Identification of System: CVCS Boron Addition and Recycle S

Date

Sheet

Unit

10/25/00

1 of 2

4

WON' 29013107 01 CR9: N/A

Type Code Symbol

Authonzation Numi

Expiration Date

ystem 0: 46 Quality Group

"tSOw Orgaft4=n. P.O. meo. jb Me. d".

Stomp N/A

fer N/A

N/A

5. (a) Applicable Construction Code 131.1

(b) Applicable Edition of Section XI Utilized for Repairs or Repleosmente

19 SS Edition,

1989 Edition.

N/A Addenda.

N/A Addenda,

N/A Code Case

N/A Code Case

6. Identification of Components Repaired or Replced and Replacement Comporents

ASME Repired. Code

Name of Name of Mfg Mfg SoAal d Other Year Replaced, or Stamp

Component Number B.ead Identification Built Replacememt Yes/No

BONNET (1). 2' MANUAL N/A N/A N/A STK CODE 52627 1 UNK REPLACEMENT N

DIAPHRAGMASME SA351 UTC 433899

7. Description of Work:

REPLACED BONNET ON VALVE 4-313A. VALVE BODY AND BONNET WAS REQUSITIONED FROM STORES UNDER STOCK CODE #

52627 1, ONLY THE BONNET WAS UTIUZED FOR THIS REPLACEMENT.

8. Tests Conducted: Hydroetato: N/A Pnemende N/A Nominal opereting Pressure

Pressure 170 psig Test Temperature 81 deg F

1. Owner

2. P1ant

Other VT-2

X

00-021-4

Page 53: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

00-021-4

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report we correct end this replaoement conforms to the rules of the ASME Code, Section XI.

N/ATVe Code Symbol Stamp

Expiration Date: N/ACertificate of Authorization No.

DateSignedOwner or Owner's Designee, Title

'- 0

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by Factory Mutual Insurance Company of Johnston. Rhode Island, have inspected the components described in this Owners Report during the period of 5/21/00 to 10/25/00

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor hWe smpayer makes any warranty, expressed or implied,

concerning the examinations and corrective meeree descrbed in this Owners' Report. Furthermore, neither the Inspector nor his emloyer shell be liable in an manner for any personal injury or property damage or a loss of any kind arlsing from or connected with this inspection.

Comevnismone -712, 3National Board. State, Providence. and Endorserms.s

--- ns''ctor's Signature

Date Wo.,.

56 Agi- -

I

N/A

Page 54: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Pro-esinee of the ASME Code Section XI

Florida Power & Light

700 Universe Blvd. Juno Beach, FL 33408

Turkey Point Plant

m7o 97W0 SW 344 Street Florida City, Fl. 33035

3. Work Performed by Florida Power & LightNmm

9760 SW 344 Street Roride City, FL 33035

4. Identification of System: CVCS Charging and Letdown

Date

Sheet

Unit

10/25/00

I of 2

4

WOC* 20009247 01 CR0: N/A

Repai Or amA"n P.O. ow. Jo M -, d.

Type Code Symbol Stamp N/A

Authorization Number NIA

Expiration Date N/A

System #: 47 Quality Group a

5. (a) Applicable Construction Code 831.1

(b) Applicable Edition of Section XI Utilized for Repairs or Replacerments

19 S5 Edition, N/A Addenda.

19 89 Edition. N/A Addenda,

6. Identification of Components Repaired or Replaced end Replacemem Components

ASME Repaired. Code

Name of Name of Mfg Mfg Seuld Nelonal Other Year Replaced, or Stamp

Component Number Beau Identification Built Replacememt Yea/No

(1) RELIEF VALVE, NIA SEE # 7 NIA NIA UNK REPLACEMENT N

STAINLESS STEEL NIA

7. Descnption of Work:

REPLACED RELIEF VALVE RV-4-203 (SERIAL # NO2705-00-00041 WITH SPARE REUEF VALVE (SERIAL # N82706-00-0002).

8. Tests Conducted: Hydrostatic: X Pneumatic N/A Nominal Operating Pressure

Other VT-2 Pressure 2230 psig Test Temperature 547 dog F

1. Owner

2. Plant

N/A

NIA

Code Case

Code Case

N/A

00-022-4

Page 55: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

I

Sheet 2 of 2FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report we correot and this replacement conforms to the rules of the ASME Code, Section Xl.

N/AType Code Syrmtoi Stamp

Expiration Date: N/A

Date UA

Certificate of Authorization No.

i-'U. " -4

Owner or Owner's Deesignes Tide

00-022-4

CERTIFICATE OF W4SENVICE INSPECTION

I, the undersigned. holding a valid commirsion issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and mployed by Factory Mlutual Inourance Company of Johnston, Rhode Island, have inspected the components described in this Owners Repert during the period of 1/4/99 to 10/25/00

end state that to the best of my knowledge end belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificato neither the Inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor his employer shall be liable in any nmane for any personal injury or property damage or a loss of my kind wising from or connected with this inspection.

Comrrismoonl Srl n e o National Board. Stat.o. Providence. and EndorsementsInspectors Signature

Date )11h IF)I I

• --- '" • Aa' 1:2l L/r

N/A

Page 56: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

1. Owner

2. Plant

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Date Newa

700 Universe Blvd. Juno Beach, FL 33400 Sheet

Tu,,rksu Pnint Plant Unit

Nasm

9760 SW 344 Street Florida City, FL 33035

10/25/00

of

4

2

WOO: 29008421 01 CR9: 99-0707

Adr Raeper OfgaflzaUen, P.O. Ne. Job . sec.

3. Work Performed by Florida Power & Light Type Code Symbol Stamp N/A

Authorization Number N/A

9760 SW 344 Street Florida City, FL 33035 Expiration Date N/A MAddessEprtonDt I

4. Identification of System: CVCS Charging and Letdown System #: 47 Quality Group B

5. (a) Applicable Construction Code a31.1 19 55 Edition. N/A Addenda, N/A Code Case

(b) Applicable Edition of Section XI Utilized for Relpirs or Rapleomen 1989 Edition, N/A Addenda, N416-1 Code Case

6. Identification of Comrponents Repaired or Repigoed and Replaeement Conponents

ASME

Repmred. Code

Nore of Name of Mfg Mfg Sed lNatiodal Other Year Replaced, or Stamp

Component Numbe Bod Identification Built Replacemernt Yes/No

(1) VALVE, 2' GLOBE S.S. N/A N/A N/A STK CODE 53130 1 UNK REPLACEMENT N

UTC 396545

(2) REDUCER, N/A N/A N/A STK COOE 237058 1 LINK REPLACEMENT I N

SEAMLESSASME UTC 434084 SA403,WP316 SCH 160

7. Description of Work:

REPLACED GLOBE VALVE 4-333 AND REDUCERS ON EACH SlOE OF VALVE.

8. Tests Conducted: Hydrostatic: N/A

Other VT-2

Pne.nm ac N/A

Preesre 2450 psig

Nominal Operating Pressure

Test Temperature 88

X

deg F

00-023-4

, 7wr• v., w ,

Page 57: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

I

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report awe correct end this replacement conforms to the rules of the ASME Code. Section XI.

Type Code Sy"bol Stamp N/A

Certificate of Authorization No.

Signedwnero On4

N/A

Pr's Oesignee. Titde

CTIFICATE OF INSERVCE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Sailer and Pressure Vessel Inspectors and the state of Rodrda and employed by Factory MtuVd Inlurance Company of Johnston, Rhode Island, have

inspected the components deseribed in this Owners Report during the period of 8/g/00 to 10/25/00

and state that to the beet of my knowledge and billet, the Owner has performed examinations and taken corrective

mesures deecmribd in this Owners' Report in accoodence with the requirements of ASME Code, Section XI.

By sagnng this coertiflote neither the Inspector nor his mployer makes any warranty, expressed or implied,

concerning the examinationu ind corrective measures described in this Owners' Report. Furthermore, neither

the Inspector nor hie employer ohll be liable in any mntner far any personal injury or property damage or a lose of any kind aisin from or connected with thils inspection.

Comord.sons G ; 0 S I rr-dd o e Natlnei Board. Stats. Providmene end Endorsements

L/Dote /1 -7/U/"

Inspector's Signature

Expiration Dote: N/A

Oats

00-023-4

- 44ýý

Page 58: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

Date

Sheet

Unit

Florida Power & LightName

700 Universe Blvd. Juno Beach, FL 33400

Turkey Point PlantName

9760 SW 344 Street Florida City, FL 33035Adde

3. Work Performed by Rorida Power & Light Neo

9760 SW 344 Street Florida City, FL 33036

4. Identification of System: Reactor Coolant System #' 41

10/30/00

1 of 2

4

W0 :30006911 01 CR9: N/A

Repaikr Orentzalk". P.O. "a, Job N,@., me.

Type Code Symbol Stamp N/A

Authorization Number N/A

Expiration Date N/A

Quality Grouo A

5. (a) Applicable Construction Cod. 831.1

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements

19 55 Edition,

1989 Edition.

N/A Addenda,

N/A Addenda,

N/A Code Case

N/A Code Case

6. Identification of Components Repaired or Replaced end Replecoment CompOnents

ASME Repaired, Code

Name of Name of Mfg Mfg Sral National Other Year Replaced, or Stamp

Component Number Bead Identification Built Replcemeamt Yes/No

RELIEF VALVE L), 4W N/A sMI Eow N/A STK COOE 53561 1 UNK REPLACEMENT N

UTC 388249

NUT, (1) HEAVY HEX, ASME NIA N/A N/A STK COOE 27840 1 UNK REPLACEMENT N

SA-194 GR 2H UTC 428811

NUT, (6) HEAVY HEX, ASTM N/A N/A N/A STK COOS 27861 1 UNK REPLACEMENT N

A-194 GR 7 UTC 428635

LI

7. Description of Work:

REPLACED VALVE RV-4-S5S1 (SERIAL # 411877-00-0005) WITH SPARE VALVE (SERIAL 5 69877-00-0004). ALSO REPLACED (7)

NUTS.

8. Tests Conducted: Hydrostatic: N/A

Other VT-1, VT-2

Pneumatic N/A

Pressure 2280 pug

Nominal Operating Pressure X

Test Temperature 547 dog F

1. Owner

2. Plant

00-024-4

S.... . -- -- r

Page 59: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report wre correct and this replacement conforms to the rules of the ASME Code, Section XI.

Type Code Symbol Stamp N/A

Certificate of Authorization No. N/A Expiration Oats: N/A

� 1 I(i � N/ A A a-

SOwner or Owner's Designee. Trio

Sheet 2 of 2

Signed Date (I 0C

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid comrriesion issued by the National Board of Boaer and Pressure Vessel Inspectors and the state of Florida and employed by Factory Mu~tual Ineurance Company of Johnston, Rhode Island, have inspected the components described in this Owners Report during the period of 4/10100 to 10/30/00 and state that to the beet of my knowledge and belief, the Owner has performed exearinatioon and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By sgning thi coertificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the exawunaitons end corrective meumwae described in this Owners' Report. Furthermore, neither the Inspector nor hie employer shall be liable in any manner for any personal injury or property damage or a lose of any kind arising from or connected with this inspection.

a _--~/osigntreN_____ Corrnii Son, q r< dr

U IsetrsSignature Natinl DodSeM State. Provicdence. end Endorserme.Ws

Date _____________

00-024-4

Page 60: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisons of the ASME Code Section X1

Date

Sheet

Unit

Florida Power & LightNme

700 Universe Uvd. Juno Beach, FL. 33406 AMMNm

2. Plant Turkey Point Plant Nme

9760 SW 344 Street Florida City, FL 33035

3. Work Performed by Florida Power & Light Maine

9760 SW 344 Street Florida City, Fl. 33035

4. Identification of System: Reactor Coolant System 8: 41

10/30/00

I of 2

4

WOO: 30006912 01 CR9: N/A

Repair Orpaniz~O, P.O. Mie, Job "a., -,t-.

Type Code Symbol Stamp N/A

Authorization Number N/A

Expiration Date N/A

Quality Group A

5. (a) Applicable Construction Code 931.1 19 55 Edition,

(b) Applicable Edition of Section X1 Utilized for Repairs or ReP1aomemMnt 1989 Edition,

6. Identification of Components Repaired or Replacod and Repladgrnet Components

Name of Component

RELIEF VALVE (1) 4"

Noae of MfgMfg Sded

N/A Addenda,

N/A Addenda,

I -I T - - r III

National 01-A~n Other IdAntilf~atlan

Year Built

N/A Code Case

N/A Code Case

Repaired, Replaced, or Replacememt

Nube Identification t

N/ASE BLO N/A STK COOE 176173 1

UTC 419093

UNK REPLACEMENT

I ______ I 4-+

___________ 1.-s T

marww. Code Stamp Yes/No

N

7. Description of Work:

REPLACED VALVE RV-4-SSIC (SERIAL 5 W51249-1361) WITH SPARE VALVE (SERIAL # HS1 249158!).

8. Tests Conducted: Hydrostatic: N/A Pneumedft N/A Nominel Operating Pressure

Preeewe 2230 peig Test Temperature 547 dog FOther VT-2

X

00-025-4

I I I - I

I •w•r

Page 61: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

I

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl.

N/AType Code Syibol Stamp

Expiration Date: N/A

o.Date (t,Signed &ký

V w ero

Certificate of Authorization No.

Owner's Oeeignee, Title

00-025-4

CERTIFICATE OF MMNMVWE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler end Pressure Vessel Inspectors

end the state of lorida and employed by Factory Atual Ineuirnce Company of Johnston, Rhode Island, have

inapected the components deecribed in this Ownes Repert during the period of 4/10/00 to 10/30/00

and state that to the beet of my knowledge and belief, the Owner has performed exarninatione and taken corrective

measures described in this Owners' Report in accordance with the requirements of ASME Code, Section Xl.

By signing ti coertificate neither the Inspector nor hi. employer make. any warranty, expressed or implied,

concerning the examinatione and corrective mesauree deocribed in thie Owners' Report. Furthermore, neither

the Inspector nor his employer shli be liale in any manne for any personal injury or property damage or a loss

of any kind arising from or connected with this inopetimn.

ie~n ConmniesoneInspector's Signature

Date /-7/_ __ ___0

-,WE,- X14firxvwýNIA

N/A

National lewil, Staem, Providence, and Endorsemeints

Page 62: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

1. Owner

2. Plant

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisione of the ASME Code Section XI

Florida Power & iUght Date Nam

700 Universe Blvd. Juno Beach, FL 33408 Sheet

AddrmPt

Turkew Point Plant unlitNale

9760 SW 344 Street Florida City, FL 33036

WON: 3000691

10/30/00

of 2

4

001 CR9: N/A

8. Tests Conducted: Hydrostatic: N/A

Other VT-2

Pneumaeba N/A

Pressure 2280 psig

Nominal Operating Pressure X

Test Temperature 547 dog F

00-026-4

Adm *wsjr OtlRsew r"Aies. P o. me, jeo we., at.

3. Work Performed by Florida Power & Ught Type Cod* Symbol Stamp N/A Authorization Number N/A

9760 SW 344 Street Florida City, FL 33035 Expiratin Date N/A

4. Identification of System: Reactor Coolant System #: 41 Quality Group A

S. (a) Applicable Construction Code B31.1 1955 Edition. N/A Addenda, N/A Code Case

(b) Applicable Edition of Section Xl Utilized for Repaimr or Replacements 1989 Edition, N/A Addends. N/A Code Case

6. Identification of Components Repaired or Replaced and Replaoement Components

ASME Repaired, Code

Name of Name of Mfg Mfg Sedd National Other Year Replaced, or Stamp

Component Number Bard Identification Built Replacememt Yes/No

RELIEF VALVE 11). 4" NIA EE BELOA NIA $TK CODE 53661 1 UNK REPLACEMENT N

UTC 3819085

7. Description of Work:

REPLACED VALVE RV-4-651 A (SERIAL # HS1 249-1362) WITH SPARE VALVE (SERIAL H 5S1 249-1579).

Page 63: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Beck)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the rert wre correct and this replacement conforms to the rules of the ASME Code, Section XI.

N/AType Code Symbol Stamp

Expiration Date: N/A

- Date ((/.11 00

0

Certificate of Authorization No.

Owner or Owner's Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a vaed commission issued by the National Board of Boiler end Pressure Vessel Inspectors end the state of Rode and employed by Factory KWW Inewance Conpany of Johneton, Rhode Island, have inspected the components described in this Owners Report during the period of 4/10/00 to 10/30/00 and state that to the best of my knowledge and belief, the Owner has performed exmninations and taken corrective meaeures desced in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certifcte neither the Inspector nor Wie emplyer makes any warranty, expressed or implied, concerning the exantinatlone and corrective measures deecilibd in this Owners' Report. Furthermore, neither the Inepeotor nor Si employer shall be aisdN in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

CoNm issions N -y P d n 3An National Dowd, State, Providence. end EndorsemetmsInspectors Signature

Data I I/ it

00-026-4

N/A

- I I

i

WgFvý

C, V-e

Page 64: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

FRondd Power & Light

700 Universe Blvd. Juno Beach. FL 33408

Turkey Point Plant

Date

Sheet

Unit

Mie

9760 SW 344 Street Florida City, Fl. 33035

by

4. Identification of System:

AddM

Florida Power & Light"4a11

9760 SW 344 Street Florida City, FL 33035

Main Foedwater

10/30/00

1 of 2

4

WOO: 30002493 01 CRO: N/A

Type Code Symbol

Authorization Nurni

Expiration Date

System 0: 74 Quality Group

"oW~m O•DWU~, P.O. Me. Job No., 9C©.

Stamp N/A

oer N/A N/A

5. (a) Applicable Construction Code S31.1

(b) Applicable Edition of Section XI Utilized for Repairs or Replacement•

19 55 Edition,

1989 Edition,

N/A Addends.

N/A Addenda,

N/A Code Case

N/A Code Case

6. Identification of Components Repaired or Replaced and Replacement Components

ASME Repaired, Code

Name of Name of Mfg Mfg SeISI No"" Other Yew Replaced, or Stamp

Component Number Bead Identification Built Replacememt Yea/No

NUT (8) HEAVY HEX. C.S. N/A N/A N/A $TK CODE 27084 1 UNK REPLACEMENT N

ASME SA-194 GR 2H UTC 433908

ROD, THREADED (6) STUDS N/A N/A N/A STK CODE 29493 1 UNK REPLACEMENT N

FABRICATED ASME SA-193 UTC 431593 GR 87

7. Description of Work:

REPLACED (8) NUTS AND E8) STUDS ON VALVE BONNET 4-20-333.

8. Toets Conducted: Hydrostatic: NIA

Other NIA

Pneumade N/A

pressure N/A poig

Normir Operating Pressure N/A

Teat Temperature N/A dog F

00-027-4

1. Owner

2. Plant

3. Work Performed

Page 65: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Sheet 2 of 2

FORM NIS-2 (Back)

9. Remarks BOLTED CONNECTION, NO WELDING REQUIRED.

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report awe correct and this replacement conforms to the rules of

the ASME Code, Section Xl.

N/AType Code Symbol Stamp

Expiration Date: NIA

Date ( 2�1 NSignedOwnew or Owner's Designoe, Title

c1IRCATU OF W11E1ICE INSPECTION

I, the undersigned, holding a valid comrnision issued by the National Board of Boiler and Pressure Vessel Inspectors

and the state of Florid and employed by Factory Mutual Ineurance Company of Johnston. Rhode Island. have

inspected the components described In this Owners Report during the period of 5/8/00 to 10/30/00

and state that to the beot of my knowledge and belef, the Owner has performed examinations and taken corrective

measures dooeribed in this Owners' Report in accordance with the requirements o~f ASME Code, Section Xl.

By s.igng thi ertificate neither the Inepector nor hi employer makes any warranty, expressed or implied.

concerning the exarminations end correcthve measures described In this Owners' Report. Furthermore, neither

the Inspector nor NIo Omployer shal be liable in any manner for any personal injury or property damage or a loss

of any kind awisig from or connected with this inspedton.

Na$ion s Board m rrd 3oS Natona Bord.State, Providence. and Endorsemeints'e Signature"Inspeoto

Date I L P

Certificate of Authorization No.

00-027-4

N/A

Page 66: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

I

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisione of the ASME Code Section XI

Date

Sheet

Rornda Power & Light

700 Universe Blvd. Juno Beach, FL 33405

Turkey Point Plant Nam

9760 SW 344 Street Florida City, FL 33035

Unit

10/30/00

1 of 2

4

WOO: 30015586 01 CRO: 00-0114

Repeaw Organrmat"•. P.O. Ne. Joe ", etc.

LI'l

3. Work Performed by Florida Power & Light

9760 SW 344 Street Florida City, FL 33035

4. Identification of System: CVCS Charging and Letdown

Type Code Symbol Stamp.

Authorization Number

Expiration Date

System *: 47 Quality Group

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements

19 55 Edition,

19 89 Edition,

N/A Addenda,

N/A Addenda,

N/A Code Case

N416-1 Code Case

6. Identification of Components Repaired or Repleced and Replacement Components

ASME Repaired. Code

Name of Name of Mfg Mfg Serd National Other Year Replaced, or Stamp

Component Number Board Identification Built Replecemnemt Yes/No

VALVE (1) 2' GLOBE, 316 N/A N/A N/A STK COOE 53135 1 UNK REPLACEMENT N

S.S. UTC 434725

7. Description of Work:

REPLACED VALVE 4-1316.

8. Tests Conducted: Hydrostatic: N/A

Other VT-2

Pneumatic N/A

Preeeo e 2450 psig

Nominal Operating Pressure X

Test Temperature N.O.T deg F

1. Owner

2. Plant

N/A N/A

a

00-028-4

NIM

Page 67: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUAL.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report ore correct and this replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A

Sheet 2 of 2

Certificate of Authorization No.

Signed

(1

N/A Expiration Date: N/A

Owner or Owner's Designee, TitleDate LT-1c

CERTIFICATE OF INSURVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors end the state of Florida end employed by Factory Mutual Insurance Company of Johnston, Rhode Island, heve inspected the components desoribed in this Ownerws Report during the period of 9/9/00 to 10130/OO and state that to the best of my knowledge and belief, the Owner has performed examinations end taken corrective measures described in this Owners' Report In accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employor makes any warranty, expressed or implied. concerning the exameinations and corrective meaewes described in this Owners' Report. Furthermore, neither the Inspector nor hi employer shall be iNable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Comrnissione A ' ?Xd E-ndo-t 32j'es National Board, Stats, Providence. and EndiorsemenitsOate__ _ _ r__Signature Dae. Z :

00-028-4

V to- , . - - --

v

Page 68: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

Florida Power & LightNarm

700 Universe Blvd. Juno Beach, FL 33408

Date

SheetAddress

Turkey Point Plant Unit

WO#: 30008436 01

4

CR# N/A

3. Work Performed by

4. Identification of System:

Florida Power & LightNam

9760 SW 344 Street Florida City, FL 33035 Address

Containment Airlocks / Hatches

Type Code Symbol Stamp

Authorization Number

Expiration Date

System #: 51 Quality Group

5. (a) Applicable Construction Code B31.1

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements

6. Identification of Components Repaired or Replaced and Replacement Components

19 55 Edition, N/A Addenda,

19 92 Edition, 92 Addenda,

N/A Code Case

N/A Code Case

Name of Component

Name of Mfg Mfg Serial National Number Board

Other Identification

Repaired, Year Replaced, or Built Replacememt

HEAVY HEX NUT (2) ASTM A- UNK UNK N/A Stock Code 0027975 1 UNK Replacement 194 GR 4, 1"-8 UNC-2B UTC 429857

UTC 42985

7. Description of Work:

REPLACE UNDERSIZED BOLTING

8. Tests Conducted: Hydrostatic: N/A Pneumatic N/A Nominal Operating Pressure

Pressure N/A psig Test Temperature

1. Owner

2. Plant

11/28/00

Namn

9760 SW 344 Street Florida City, FL 33035 Address

of 2

Repair Organizatbon, P.O. No, Job No., etc.

N/A

NIA

NIA

MC

ASME Code Stamp Yes/No

N

Other N/A

N/A

N/A deg F

00-029-4

1

Page 69: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 (Back)

9 Remarks BOLTED CONNECTION. NO WELDING REQUIRED.

Sneet 2 of 2

CERTIFICATE OF COMPLIANCE

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI.

TypeCodeSymol SainN/A

Certificate of thorization No N/A Expiration Date

Signed Dcat

Owner or Owneks Designee, Title

CERTIFICATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the state of Florida and employed by Factory Mutual Insurance Cmrnnnv of Johnctnin Dhode Island, have inspected the components described in this Owners Report during 1 5/3/00 1 do 11/28/00 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code,

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ii - - r

National Board. State. Providence. and Endorsements'• U 1nspector's Signature

Dat

00-029-4

N/A

Type Code Symbol Stare

N/A

!

Page 70: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FORM NIS-2 OWNERS REPORT FOR REPAIRS OR REPLACEMENTS

As Required by the Provisions of the ASME Code Section XI

Florida Power & Light Date 12/14/00

Name

700 Universe Blvd. Juno Beach, FL 33408 Sheet 1 of 2

Address

T.,,-.,, Pnont Plant Unit 42. Plant 7"•° ' .. . ..

Name

9760 SW 344 Street Rorida City, FL 33035

WO#: 30019143 01 CR#: 00-1650

Address Repair Organization, P 0. No. Job No.. etc

3. Work Performed by Florida Power & Light Type Code Symbol Stamp N/A Name Authorization Number N/A

9760 SW 344 Street Florida City, FL 33035 Expiration Date NIA Address

4. Identification of System: Emergency Diesel Engine and Oil System #: 22 Quality Group C

5. (a) Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Cod

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Edition, N/A Addenda, N/A Cod

6. Identification of Components Repaired or Replaced and Replacement Components

Name of Comnonnent

3" Tee, Sch 40 SA 403. 316 SS

Name of Mfg Mfg Serial Number

NA NA

National Board

Comnonen

NA

Other Identification

Year Built

UNKSC 0035133 1

UTC 381879 -

Repaired, Replaced, or Replacememt

Replacement

3" Pipe, Sch 40, SA 312, NA NA NA SC 0030911 1 UNK Replacement

316 SS UTC 374076 "

Bar Stock, ASTM A 240, NA NA NA SC 0223204 1 UNK Replacement

Type 316 SS, 3" x 1/2" UTC 418529 (Welded attachment)

(2) 3" Elbows. Sch 40, SA 403, 316 SS

NA NA NA

t _________ L 4. .4

3" Sch 40 x 1/2" Sch 80 Reducer, SA 403, 316 SS

NA NA

I~ IL

NA

UNKSC 0034893 1

UTC 435075

Replacement

UNK ReplacementSC 0238223 1

UTC 4350793

ASME Code

Stamp Yes/No

N

N

N

N

N

7. Description of Work:

Replaced leaking pipe per CR 00-1650 & PCM 00-035

8. Tests Conducted: Hydrostatic: No

Other VT-2

Pneumatic Yes

Pressure 200 psig

Nominal Operating Pressure NOP

Test Temperature 82.7 deg F

00-031 4

1. Owner

e Case

e Case

I

Page 71: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

SSheet 2 of 2

FORM NIS-2 (Back)

9. Remarks ALL WELDING PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUAL. CODE CASE N-416.1 WAS INVOKED FOR THIS REPLACEMENT ACTIVITY.

CERTIFICATE OF COMPLIANCE

N/A

Certificate of : %horization No. N/A Expiration Date:

Signed 6 /O I Dat,"O wner or Owners Designee, Title

N/A

• (00

CtRTIFICATE OF INSERVICE INSPECTION

I, n.! md.ersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors ana :*2 state of Florida and employed by Factory Mutual Insurance Company of Johnston, Rhode Island, have insoý. -.d the components described in this Owners Report during the period of 10/20/00 to 12/14/00 aic -zate that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Report in accordance with the requirements of ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shell be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions A115 7-7"< OW f 7, C& National Board. State, Providence. and Endorsements

Date JP/I1A

U Inspector's Signature

00-031 4

Type Code Symbol Stamp

ý:: A>-t

Page 72: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT UNIT 4

2000 REFUELING OUTAGE

Form NIS-BB Owner's Data Report for Eddy Current Examination Results

Page 73: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

CSI-NDE-O0-078 Attachment 1

II

Page 1 of 1 FORM NIS-BB OWNERS' DATA REPORT FOR EDDY CURRENT EXAMINATION RESULTS

As required by the provisions of the ASME CODE RULES

EDDY CURRENT EXAMINATION RESULTS

PLANT: Turkey Point Unit 4

EXAMINATION DATE: October 4, 2000 thru October 9, 2000

TOTAL TOTAL TOTAL TUBES TUBES TOTAL STEAM TUBES TUBES TUBES PREVENTIVELY PLUGGED PLUGGED

GENERATOR INSPECTED 20%-39% >40%, PIT & PLUGGED (PTP) THIS TUBES VOL OUTAGE IN S/G

4E210A (Bobbin) 1602 0 0 0 0 See RPC 4E210B (Bobbin) 1604 1 (1) 0 1 (2) 1 (2) See RPC 4E210C (Bobbin) 1607 3 (1) 0 1 (3) 1 (3) See RPC

4E210A (RPC) 3242 (4) 0 2 1 (5) 3 (6) 19 4E210B (RPC) 3247 (4) 0 4 0 4(6) 13

4E210C (RPC) 3254(4) 0 1 0 1 (6) 11

LOCATION OF INDICATIONS (20% - 100%, PIT & VOL)

Tube Tube Freespan Top of Top of Total Total STEAM AVB Supports Supports 6H thru 6C Tubesheet Tubesheet Indications Indications

GENERATOR Bars 1 thru 6 1 thru 6 UBEND to #1 to #1 20%-39% >40%, PIT C/L H/L Support C/L Support H/L & VOL

4E210A (Bobbin) 0 0 0 0 0 0 0 0 4E210B (Bobbin) 1 (1) 0 0 0 0 0 1 0 4E210C (Bobbin) 30) 0 0 0 0 0 3 0

4E210A (RPC) 0 n/a n/a 0 n/a 2 n/a 2 4E210B (RPC) 0 n/a n/a 0 n/a 4 n/a 4 4E210C (RPC) 0 n/a n/a 0 n/a 1 n/a 1

Remarks: (1) Mechanical wear damage at anti-vibration bars (AVB) was depth sized using qualified bobbin coil sizing technique. (2) One tube in 4B was preventatively plugged due to minor wear at the hot leg baffle plate. (3) One tube in 4C was preventatively plugged for AVB wear progression. (4) Includes tubes in the dent, low row U-bend and hot leg TTS expansion transition programs. (5) One tube in 4A was preventatively plugged due to permeability in the hot leg expansion transition area. (6) Includes volumetric (VOL) and pit (PIT) like indications.

Page 74: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

CSI-NDE-00-078 Attachment 2

Page 1 of 2

PTN-4 S/G "B

Indication Report

ROW COL CAL

34 46 BC009

TOTAL INDICATIONS: 1

TOTAL TUBES: 1

VOLTS

0.55

DEG

0

CH

P2

10/16/00 9:40:28 AM

Page 1 of 1

% IND SUPPORT INCHES

20 AV2 -0.35

Page 75: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

CSI-NDE-00-078 Attachment 2

Page 2 of 2

PTN-4 S/G "C

Indication Report

ROW COL CAL

13 43 CCO06

32 70 CCO12

35 31 CC013

TOTAL INDICATIONS: 3

TOTAL TUBES: 3

VOLTS

1.07

0.61

0.67

DEG

0

0

0

CH

P2

P2

P2

% IND SUPPC

36 AV3

24 AVI

28 AV2

10/16/00 9:43:24 AM

Page 1 of 1

ORT INCHES

-0.79

-0.09

0.15

Page 76: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

CSI-NDE-00-078 Attachment 3

Page 1 of 3

PTN-4 S/G "A

Pluggable Indications

ROW COL CAL

12 25 AH009

26 80 AH028

33 73 AH029

TOTAL INDICATIONS: 3

TOTALTUBES: 3

VOLTS

0

0.16

0.41

DEG

0

92

114

CH %

0

P1 0

P1 0

IND

PTP

PIT

VOL

10/16/00 9:37:17 AM

Page 1 of 1

SUPPORT INCHES

0

TSH 2.27

TSH 0.17

Page 77: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

CSI-NDE-00-078 Attachment 3

Page 2 of 3

PTN-4 S/G "B

Pluggable Indications

ROW COL CAL

2 90 BH056

20 80 2H025

21 80 BH024

29 62 BH007

43 51 BH023

TOTAL INDICATIONS: 5

TOTAL TUBES: 5

10/16/00 9:41:42 AM

Page 1 of 1

VOLTS DEG CH % IND SUPPORT INCHES

0 0 P4 0 PTP BAH -0.46

023 114 P1 0 PIT TSH 0

0.08 91 P 1 0 PIT TSH 0.05

0.07 84 P1 0 PIT TSH 0.12

0.25 107 P 1 0 PIT TSH -0.04

Page 78: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

CSI-NDE-O0-078 Attachment 3

Page 3 of 3

PTN-4 S/G "C

Pluggable Indications

ROW

3

COL

91

CAL

CHO 11

13 43 CH035

VOLTS

0.86

0

DEG

81

CH

P1

0

0

10/16/00 9:43:17 AM

Page 1 of 1

IND SUPPORT INCHES

PIT TSH 0

0 PTP AV3 -0.79

TOTAL INDICATIONS:

TOTAL TUBES:

2

2

%

Page 79: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT UNIT 4

2000 REFUELING OUTAGE

SUMMARY OF VISUAL EXAMINATIONS AND FUNCTIONAL TESTING OF SNUBBERS

Page 80: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Abstract

The attached report details the snubber inspection/testing performed for Florida Power and Light Company, Turkey Point Unit 4. These tests and inspections were performed during the fall 2000 refueling outage, between the dates of September 25, 2000 and October 23, 2000.

Snubber inspection/testing was conducted in accordance with Plant Technical Specifications as allowed under Relief Request 4 of the Third Ten-Year Interval ISI Program.

Page 81: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

TAG #

4-1004

S

VISUAL T SERIAL # REPLACE- INSPECT A

MENT S/N DATE T

1 3168 1 N/A 1 9/25/001 P

4-1009 1 1228 1203 9/26/00 P

S S S FUNCTIONAL T T HAND. T

INSPECT A A STROKE A DATE T L DIMEN T ? T VISUAL SUMMARY FUNCTIONAL TEST SUMMARY

10/9/00 P 27 1/4" P Yes P THIS SNUBBER WAS SCHEDULED FUNCTIONAL TEST PERFORMED? Yes FOR REBUILD PER CR 97-399. SNUBBER WAS VISUALLY STATUS P INSPECTED, REMOVED FROM ONE END AND HANDSTROKED, THEN TENSION COMPRESSION CRITERIA REMOVED COMPLETELY TO BE REBUILT AND FUNCTIONALLY TEST 1 1690 129.3 2500.0 TESTED. REINSTALLED AND TEST 2 291.8 364.0 2500.0 LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH TEST 3 0.003 0.004 .02g NEOLUBE #24982-3.

9/28/00 1 P 27 1/2" P Yes P THIS SNUBBER WAS SCHEDULED FOR REBUILD PER CR 97-399. SNUBBER WAS VISUALLY INSPECTED, IT WAS DIFFICULT TO HANDSTROKE SO IT WAS REMOVED AND TRANSPORTED TO THE TEST BENCH TO STROKE. AFTER TEST MACHINE STROKE IT WAS TORN DOWN FOR REBUILD. THE SNUBBER HAD WORN PARTS AND WAS REPLACED WITH S/N 1203 AFTER FUNCTIONAL TEST. LUBRICATED LOAD PINS AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

TEST 4 307.6

TEST SAMPLE?

604.2 2500.0

No SAMPLE CLASS N/A

DATE REINSTALLED: 9/27/00

FUNCTIONAL TEST PERFORMED? Yes

STATUS P

TENSION COMPRESSION CRITERIA

TEST 1 193.5

TEST 2 221.6

TEST 3 0.007

TEST 4 326.9

TEST SAMPLE?

222.5

483.1

0.008

486.1

2500.0

2500.0

.02g

2500.0

No SAMPLE CLASS N/A

DATE REINSTALLED: 9/29/00

Page 82: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

SFUNCTIONAl VISUAL T INSPECT

SERIAL # REPLACE- INSPECT A DATE

TAG # MENT SIN DATE T DATE

4.1004 1 3168 1 N/A 1 9/25/001 P 1 10/9/00

S S S L T T HAND- T

A A STROKE A

T L DIMEN T ? T VISUAL SUMMARY FUNCTIONAL TEST SUMMARY

P 27 1/4" P Yes P REMOVED SNUBBER FROM ONE END FUNCTIONAL TEST PERFORMED? Yes

AND STROKED, THEN REMOVED COMPLETELY TO BE FUNCTIONALLY STATUS P TESTED AND REBUILT- REINSTALLED TE S O ......... .... I . l~, Nl nl

AND LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3 TEST I

TEST 2

TEST 3

TEST 4

TENSION

169.0

291.8

0.003

307,6

TEST SAMPLE?

COMPRESSION

129.3

364.0

0.004

604.2

DATE REINSTALLED:

CRI I ERIA

2500.0

2500.0

.02g

2500.0

9/27/00

_________ J _________ I __________ I __________ I ________ I __________ L...............E ___________ I _______ _______ 1 __________________________________________ .1. ________________________________________________________________ Yes

4-1009 1 1228 1203 9/26/001 P 9/28/00 P 27 1/2" P Yes P SNUBBER HANDSTROKED AND REMOVED FOR FUCTIONAL TEST AND REBUILD. SNUBBER HAD WORN PARTS AND WAS REPLACED WITH S/N 1203. LUBRICATED LOAD PINS AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

FUNCTIONAL TEST PERFORMED?

STATUS P

TEST 1 TEST 2

TEST 3

TEST 4

TENSION

193.5

221.6

0.007

326.9

TEST SAMPLE? No

DATE REINSTALLED:

COMPRESSION

2225

483 1

0.008

4861

CRITERIA

2500.0

2500 0

.02g

25000

_________ I _________ I __________ __________ I ________ I __________ � ___________ I _______ � __________________________________________ .1 ________________________________________________________________

No SAMPLE CLASS N/A

SAMPLE CLASS N/A

9/29/00

Yes

Page 83: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S S S S VISUAL T FUNCTIONAL T T HAND- T

SERIAL# REPLACE- INSPECT A INSPECT A A STROKE A SERIL # EPLCE- NSPET A DATE T LDMN T ? TVSA UMR

MENT SIN DATE T T L DIMEN T ? T VISUAL SUMMARY FUNCTIONAL TEST SUMMARY .. ............ I................................................... ,....... -......-....... ;.................... . ... ... .... . ... ... ... ... ... ... .

16243 N/A 10/2/00 P 10/2/00 P 22 5/8" P No N/A PERFORMED VISUAL INSPECTION. FUNCTIONAL TEST PERFORMED? Yes

REMOVED FOR FUNCTIONAL TEST (SAT). REINSTALLED SNUBBER. STATUS P LUBRICATED LOAD PIN AND

-tt-^ AlOlkif•c! kAlITI- TENSION COMPRESSION CRITERIAN-Er-lrUE r 24,IL DC8 NEOLUBE 24982-3.

TEST 1

TEST 2

TEST 3

TEST 4

49.2

66.3

0.010

77.5

TEST SAMPLE? Yes

DATE REINSTALLED:

28.6

51.9

0.007

22.3

750 0

7500

.02g

750.0

SAMPLE CLASS SR

10/2/00

_______ [ ______ I ________ [ _______ i ______ _______ i ____ ________ _____ ______________________________ L _____________________________________________ FUNCTIONAL TEST PERFORMED? Yes

4-1036 1 11461PERFORMED VISUAL INSPECTION. SNUBBER REMOVED AND TAKEN TO TEST MACHINE FOR STROKE/REGREASE/REBUILD. LUBRICATED LOAD PINS AND SPHERICAL BEARINGS, REINSTALLED SNUBBER.

FUNCTIONALTEST PERFORMED?

STATUS P

TEST 1 TEST 2

TEST 3

TEST 4

TENSION

19.5

39.8

0.010

50.9

COMPRESSION 49.5

56.7

0 008

46.9

Yes

CRITERIA

750 0

750 0

029

750,0

TEST SAMPLE? No SAMPLE CLASS N/A

DATE REINSTALLED: 10/5/00

__________ I __________ I ____________ I __________ J _________ I __________ I _______ I ____________ I _______ _______ I _____________________________________________ i _____________________________________________________________________

TAG #

4.1034

N/A 10/2/001 P 10/3/00 1 P 18 5/8" P Yes IP

Page 84: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986S S S S

VISUAL T FUNCTIONAL T T HAND- T SERIAL# REPLACE- INSPECT A INSPECT A A STROKE A

MENT S/N DATE T DATE T L DIMEN T ? T ".................1.......... ...... ......... ................ ....... ........... 17419 N/A 9/28/00 P 9/30/00 P 17" P rNo N/A

VISUAL SUMMARY FUNCTIONAL TEST SUMMARY ........ I ............................ .............. ... ... ..... .... ... . PERFORMED VISUAL INSPECTION. FUNCTIONAL TEST PERFORMED? Yes REMOVED FOR FUNCTIONAL TEST (SAT). REINSTALLED SNUBBER. STATUS P LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH TENSION COMPRESSION CRITERIA NEOLUBE 24982-3

TEST 1 133

TEST 2 22.2

TEST 3 0.008

TEST 4 19.3

TEST SAMPLE?

14.8

18.5

0.013

20.9

300.0

300.0

.02g

300.0

Yes SAMPLE CLASS SR

________i ______ _______ i.........i_________ I_____ _____ I_________________________________.1 _____________________________________10______00 _

3919 17902 10/4/001 P 3/5/00 P 20 3/8" P IYes IP PERFORMED VISUAL/HANDSTROKE. REMOVED SNUBBER FOR FUNCTIONAL TEST/REBUILD. LUBRICATED PINS AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3. S/N 17902 WAS INSTALLED. S/N 3919 PUT IN STORAGE AS SPARE.

FUNCTIONAL TEST PERFORMED? Yes

STATUS P

TENSION COMPRESSION

TEST1, 60 94

TEST 2 133.65

TEST 3 0.009

TEST 4 85.57

TEST SAMPLE?

72.58

8539

0.008

6256

CRITERIA

750.0

750.0

.02g

750.0

No SAMPLE CLASS N/A

DATE REINSTALLED: 10/4/00_______ - ______ - _________ _______ _______ .I-------i L .L. .. JI

TAG #

4-1040

4-1044

DATE REINSTALLED: 10/1!00

Page 85: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S S

VISUAL T FUNCTIONAL T

SERIAL # REPLACE- INSPECT A DATE TA MENT S/N DATE T DATE T

3905 17906 10/4/00 P 10/6/00 P

I _______ �I _______ I-I -.

N/A 10/5/001 P 10/5/00 P 18 1/2"

S S T HAND- T A STROKE A

L DIMEN T ? T VISUAL SUMMARY FUNCTIONAL TEST SUMMARY

21 5.8" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? Yes

REMOVED SNUBBER FOR

FUNCTIONAL TEST/REBUILD STATUS P

LUBRICATED PINS AND SPHERICAL

BEARINGS WITH NEOLUBE #24982-3 TENSION COMPRESSION CRITERIA

S/N 17906 WAS INSTALLED S/N 3905

PUT IN STORAGE AS SPARE.

P No INIA PERFORMED VISUAL INSPECTION. REMOVED FOR FUNCTIONAL TEST (SAT). REINSTALLED SNUBBER. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE 24982-3.

TEST 2

TEST 3

54.3

0.010

TEST4 73.0

TEST SAMPLE?

36.9 0.007

47 9

300.0 .02g

300.0

No SAMPLE CLASS NIA

DATE REINSTALLED: 10/4/00

FUNCTIONAL TEST PERFORMED? Yes

STATUS P

TENSION COMPRESSION

TEST 1 262 TEST 2 400

TEST 3 0011

34 7

347

0 008

CRITERIA

750,0

7500

02g

TEST 4 480 241 7500

TEST SAMPLE? Yes SAMPLE CLASS QR

DATE REINSTALLED: 10/6/00

TAG #

4-1046

4-1060 1 12374

I L

Page 86: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S S VISUAL T FUNCTIONAL T

SERIAL # REPLACE- INSPECT A INSPECT A MENT SIN DATE T DATE T

1 2........ 5 ..................... .... .1. ... ....../... P 1 5 ... .. 111125 1 17904 1 10/4/001 P 1 10/5/00 1 P

4-1053 1 11446 16245 10/4/001 P 10/5/00 1 P

S T HANDA STROKE

S T A

L DIMEN T ? T VISUAL SUMMARY FUNCTIONAL TEST SUMMARY

22 1/2" 1 P IYes P PERFORMED VISUAL/IHANDSTROKE. I FUNCTIONAL TEST PERFORMED? Yes I REMOVED SNUBBER FOR

21 3/4" P Yes P

FUNCTIONAL TEST/REBUILD LUBRICATED PINS AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3. S/N 17904 WAS INSTALLED. S/N 11125 PUT IN STORAGE AS SPARE.

STATUS P

TENSION COMPRESSION CRITERIA

TEST1 482

TEST 2 75.2

TEST 3 0.010

TEST 4 87-1

TEST SAMPLE?

32.5

49.6

0.008

35.8

300 0

300.0

.02g

300.0

No SAMPLE CLASS N/A

DATE REINSTALLED:10/4/00

_______ L _____________________________________________ I _____________________________________________________________________

PERFORMED VISUAL/HANDSTROKE. REMOVED SNUBBER FOR FUNCTIONAL TEST/REBUILD. LUBRICATED PINS AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3. S/N 16245 WAS INSTALLED. S/N 11446 PUT IN STORAGE AS SPARE.

FUNCTIONAL TEST PERFORMED? Yes

STATUS P

TENSION COMPRESSION CRITERIA

TEST 1 14.7

TEST 2 42.8

TEST 3 0012

TEST 4 40.8

TEST SAMPLE?

42.5

744

0.007

767

300 0

300.0

0.02g

300 0

No SAMPLE CLASS N/A

DATE REINSTALLED: 10/4/00_________ - _________ - ___________ __________ ________ __________ �-..........L ___________ L _______ J.............4. I__________________________________________ I. _______________________________________________________________

TAG #

4-1051

10/4/00

Page 87: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S S S S

VISUAL T FUNCTIONAL T T HAND- T SERIAL# REPLACE- INSPECT A INSPECT A A STROKE A

TAG # MENT SIN DATE T DATE T L DIMEN T ? T VISUAL SUMMARY FUNCTIONAL TEST SUMMARY

4-1057 1 27080 27092 10/4/001 P 1 10/6/00 P 18 9/16" Yes IP PERFORMED VISUAL/HANDSTROKE. I FUNCTIONAL TEST PERFORMED? YesREMOVED SNUBBER FOR FUNCTIONAL TEST/REBUILD. LUBRICATED PINS AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3. S/N 27092 WAS INSTALLED, S/N 27080 PUT IN STORAGE AS SPARE.

STATUS P

TENSION COMPRESSION CRITERIA

TEST 1 19.7

TEST 2 24.4

TEST 3 0.003

TEST 4 24.6

TEST SAMPLE?

221

26.5

0.003

22.2

300.0

300 0

.02g

300.0

No SAMPLE CLASS N/A

DATE REINSTALLED: 10/4/00

J .1 1 I. J L...................1 J _________________________________________________ I

4-1059 1 27103 10/5/00 1 P 17" P No IN/A PERFORMED VISUAL INSPECTION. REMOVED FOR FUNCTIONAL TEST (SAT). REINSTALLED SNUBBER.

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH

NEOLUBE 24982-3

FUNCTIONAL TEST PERFORMED? Yes

STATUS P

TENSION COMPRESSION CRITERIA

TEST 1 13.3

TEST 2 26.3

TEST 3 0006

TEST 4 247

TEST SAMPLE?

160

191

0.006

21.3

300.0

300 0

02g

300.0

Yes SAMPLE CLASS SR

DATE REINSTALLED: 10/6/00

________ _______ J. _________ .1. L _______ I ________ _________ .1. ______ 1....J ______ .1. ________________________________________________________

N/A 10/5/001 P

Page 88: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S S S S VISUAL T FUNCTIONAL T T HAND- T

SERIAL# REPLACE- INSPECT A INSPECT A A STROKE A MENT SIN DATE T DATE T L DIMEN T ? T VISUAL SUMMARY FUNCTIONAL TEST SUMMARY

1 10036 1 N/A 1 9/28/001 P 1 9/29/00 1 P 1 26 3/4" 1 P I No IN/A I PERFORMED VISUAL INSPECTION. I FUNCTIONAL TEST PERFORMED? Yes

4-1072 1 16235 10/2/00 1 P 1 21 3/16" P Yes IP

REMOVED FOR FUNCTIONAL TEST (SAT). REINSTALLED SNUBBER. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE 24982-3.

Performed visual inspection, snubber was removed and taken to test trailer to stroke on bench. Although the snubber tested SAT it was tom down and the thrust bearing was replaced. Final functional was SAT. Snubber was reinstalled and pipe clamp adjusted per CR 00-1758. Lubricated loadpins and spherical bearings with neolube #24982-3.

STATUS P

TENSION COMPRESSION CRITERIA

TEST 1 798.7

TEST 2 823.4

TEST 3 0.002

TEST4 274.0

TEST SAMPLE?

227.0

674.9

0.003

197.0

2500.0

2500.0

.02g

2500.0

Yes SAMPLE CLASS SR

DATE REINSTALLED:

FUNCTIONAL TEST PERFORMED?

1011/00

Yes

STATUS P

TENSION

TEST 1 40.4

TEST 2 81.7

TEST 3

TEST 4

0.007

63.5

TEST SAMPLE?

COMPRESSION CRITERIA

32.8 750.0

42.1

0.008

38.2

750.0

.02g

750.0

No SAMPLE CLASS N/A

DATE REINSTALLED: 10/7100

TAG #

4-1070

N/A 10/2/001 P

Page 89: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S S S S

VISUAL T FUNCTIONAL T T HAND- T SERIAL# REPLACE- INSPECT A INSPECT A A STROKE A

TAG # MENT S/N DATE T DATE T L DIMEN T ? T VISUAL SUMMARY FUNCTIONAL TEST SUMMARY

4-1074 19298 N/A 9/28/00 P 9/30/00 P 17 3/4" P No N/A PERFORMED VISUAL INSPECTION. FUNCTIONAL TEST PERFORMED? Yes REMOVED FOR FUNCTIONAL TEST (SAT). REINSTALLED SNUBBER. STATUS P LUBRICATED LOAD PIN AND

#nu•Dt-^, •^•,•t^.TUTFNSRIONJ C'OMPRFRRIfN C.RITFRIA

__________ 1 __________ .1 ____________ .1. ___________ L _________ .1. ___________ L _______ L _____________ 4.

4-1078 124430A

______ J ______ ________ L _______ .1 ______ 1 _______ J ____ J ________ I _____ J ____ I _____ I

NElUBEUML D"#Mll•t- "1 1 r2 NEOLUBE 24982-3.

PERFORMED VISUAL INSPECTION. REMOVED FOR FUNCTIONAL TEST (SAT). REINSTALLED SNUBBER. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE 24982-3.

TEST 1 165

TEST 2 23.1

TEST 3 0.014

TEST 4 20.2

TEST SAMPLE?

15.6

19.0

0.004

24.4

300.0

300.0

.02g

300.0

Yes SAMPLE CLASS SR

DATE REINSTALLED:

FUNCTIONAL TEST PERFORMED?

9/30/00

Yes

STATUS P

TENSION COMPRESSION

TEST 1 2.2

TEST 2 7.5

TEST 3 0.012

TEST 4 9.7

TEST SAMPLE?

8.1

97

0012

8.3

CRITERIA

75.0

75.0

02g

75,0

Yes SAMPLE CLASS SR

DATE REINSTALLED: 9/30/00

N/A 9/28/001 P 9/30/00 1 P 13 5/8" P No IN/A

TENSION COMPRESSION CRITERIA

Page 90: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S S S S

VISUAL T FUNCTIONAL T T HAND- T SERIAL# REPLACE- INSPECT A INSPECT A A STROKE A

MENT S/N DATE T DATE T L DIMEN T ? T VISUAL SUMMARY FUNCTIONAL TEST SUMMARY

12994 N/A 9/26/00 P 9/27/00 P 27 1/2" P No N/A PERFORMED VISUAL INSPECTION FUNCTIONAL TEST PERFORMED? Yes REMOVED FOR FUNCTIONAL TEST (SAT). REINSTALLED SNUBBER. STATUS P LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH TENSION COMPRESSION CRITERIA NEOLUBE 24982-3 TEST 1 171.0 216.3 2500.0

TEST 2 255.5

TEST 3 0.003

TEST4 197.1

TEST SAMPLE?

227.1

0.003

125.7

2500 0

.02g

2500.0

Yes SAMPLE CLASS OR

DATE REINSTALLED: 9/29/00

PERFORMED VISUAL INSPECTION. REMOVED FOR FUNCTIONAL TEST (SAT). REINSTALLED SNUBBER. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE 24982-3.

FUNCTIONAL TEST PERFORMED? Yes

STATUS P

TENSION COMPRESSION CRITERIA

TEST 1

TEST 2

154.8

155 4

TEST 3 0004

TEST4 147.3

TEST SAMPLE?

99 5

124.4

0.003

146.3

2500 0

2500 0

02g

2500 0

Yes SAMPLE CLASS QR

DATE REINSTALLED: 9/29/00

TAG #

4-1087

4-1091 12998 NIA 9/26/00l P 9/28;00 1 P 29" P No

Page 91: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S S S S

VISUAL T FUNCTIONAL T T HAND- T

SERIAL# REPLACE- INSPECT A INSPECT A A STROKE A DATE TLDMN T ? TVSA UMR

TAG # MENT S/N DATE T T L DIMEN T ? T VISUAL SUMMARY FUNCTIONAL TEST SUMMARY

4-1096 17871 N/A 9/25/00 P 9/26/00 P 19 3/16" P No N/A PERFORMED VISUAL INSPECTION. FUNCTIONAL TEST PERFORMED? Yes

REMOVED FOR FUNCTIONAL TEST (SAT). REINSTALLED SNUBBER. STATUS P

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH TENSION COMPRESSION CRITERIA

NEOLUBE 24982-3. TEST 1 80.3 40.8 750.0

TEST2 110.1 40.8 750.0

TEST 3 .007 0.011 .02g

TEST 4 107.7 41.4 750.0

TEST SAMPLE? Yes SAMPLE CLASS QR

DATE REINSTALLED: 9/27/00

I__ _j _ _ _I I__ _J__ _ _ I_ __I_ _ __ 1_I_1__ _ __I _ ___ _ _iI_ _ __ _ __I_ _ __ _ __I __ _ __I_ _ __ _ __I_ _ __ _ __I_ _ _

Page 92: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

TAG# SERIAL#

4-1 032 1-3707-I

S VISUAL T

REPLACE- INSPECT A MENT S/N DATE T

-.... .G ~ - .

S FUNCTIONAL T

INSPECT A DATE T

L DIMEN

26"

S S T HAND- T A STROKE A T ? T

P

VISUAL SUMMARY

PERFORMED HANDSTROKE. LUBRICATED LOAD PIN AND SPHERICAL BEARING WITH NEOLUBE #24982-3.

FUNCTIONAL TEST SUMMARY

FUNCTIONAL TEST PERFORMED? No

I I I I I 1 1

4-1033 7001 N/A 9/28100 P 26 13/16" P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No

LUBICATED LOAD PIN AND SPHERICAL BEARINGS WITH

NEOLUBE#24982-3

4-1035 1 11439 N/A 10/2/00 P

41 11 14-1037 1 11930 N/A 10/2/00 P

.1 1 4 I I-I

21 1/4"

26 1/2"

P

P

Yes P

YesI P

PERFORMED VISUAL/HANDSTROKE. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

PERFORMED VISUAL/HANDSTROKE. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

ONAL TEST PERFORMED? No

es PP

NoFUNCTIONAL TEST PERFORMED?

FUNCTIq

Page 93: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

VISUAL REPLACE- INSPECT

TAG# SERIAL# MENT S/N DATE

0389 497 N/A 9/0/ -

S S T FUNCTIONAL T A INSPECT A T DATE T

S S T HAND- T A STROKE A

LDIMEN T ? T

-*/'16:[ N/A IYes p

VISUAL SUMMARY

PERFORMED VISUAUHANDSTROKE LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

FUNCTIONAL TEST SUMMARY

FUNCTIONAL TEST PERFORMED? No

4-1039 12988 N/A 10/3/00 P 25 5/8" P Yes P PERFORMED VISUAL ON SUPPORT FUNCTIONAL TEST PERFORMED? No

END BY USE OF MANBASKET.VISUAL/HANDSTOKE. LOAD PIN AND SPHERICAL BEARING WAS WORN, BOTH REPLACED. LUBRICATED LOAD PIN AND SPHERICAL BEARING WITH NEOLUBE #24982-3.

4-1041 19721 N/A 10/1/00 P 17 7/8" P Yes P PERFORMED VISUAUHANDSTROKE FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1042 19727 N/A 10/6/00 P 17 7/16" P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

Page 94: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

TAG # SERIAL#

VISUAL REPLACE- INSPECT MENT S/N DATE

_4-10,4-31 27099 N/ I1060

S T A T

FUNCTIONAL INSPECT

DATE

S T A T L DIMEN

17 3/8"

S ST HAND- T A STROKE A T ? T

P

VISUAL SUMMARY

PERFORMED VISUAL/HANDSTROKE. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

FUNCTIONAL TEST SUMMARY

FUNCTIONAL TEST PERFORMED? No

4-1046 187 N/A 10/5/00 P 19 1/4" P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1047 185 N/A 10/5/00 P 19 1/2" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND

SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1048 4251 N/A 10/5/00 P 20 3/16" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

P Yes

Page 95: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

VISUAL REPLACE- INSPECT

TAG# SERIAL# MENT S/N DATE

S T A T

-4 -,49"-1 0,-*9-f - ..- N/"-.. *l**1-*,5/ -. ;-

FUNCTIONAL INSPECT

DATE

S S ST T HAND- T A A STROKE A T L DIMEN T ? T

---i--1- 9- 5/-8. [1 P---r Y-es- - --P-

VISUAL SUMMARY

PERFORMED VISUAL/REMOVED FOR HANDSTROKE. LUBRICATED LOAD PINS/SPHERICAL BEARINGS WITH NEOLUBE # 24982-3. REINSTALLED SNUBBER.

FUNCTIONAL TEST SUMMARY

FUNCTIONAL TEST PERFORMED? No

4-1052 17189 N/A 10/5/00 P 21 7/8" P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1054 17899 N/A 10/5/00 P 21 7/8" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1055 17900 N/A 10/5/00 P 20 7/8" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

Page 96: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

TAG# SERIAL#

VISUAL REPLACE- INSPECT MENT SIN DATE

S T A T

FUNCTIONAL INSPECT

DATE

S T A T L DIMEN

S ST HAND- T A STROKE A T ? T

-P

VISUAL SUMMARY

PERFORMED VISUALIHANDSTROKE. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

FUNCTIONAL TEST SUMMARY

FUNCTIONAL TEST PERFORMED? No

1 I- -I 1 4-1058 21379 N/A 10/6/00 P 16 9/16" P Yes P PERFORMED VISUALIHANDSTROKE FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1061 19722 N/A 10/6/00 P 16 13/16" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3

4-1062 1 27076 N/A 10/6/00 P 17 1/8" P Yes P PERFORMED VISUAL/HANDSTROKE LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

.1 1 1 4 l-I 4 _______ _______ ___________________________________________ .4

P Yes 213/8.. 1 F-

... ..4-1056 17903..............

FUNCTIONAL TEST PERFORMED? No

- ] .....

Page 97: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

VISUAL REPLACE- INSPECT

TAG# SERIAL# MENT S/N DATE

4-1063 27098 N/A 10/6/00

S T A T

P

FUNCTIONAL INSPECT

DATE

S T A T

S S T HAND- T A STROKE A

L DIMEN T 7 T

S1-7 1/2" [ p Yes P

VISUAL SUMMARY

PERFORMED VISUAL/HANDSTROKE LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

FUNCTIONAL TEST SUMMARY

FUNCTIONAL TEST PERFORMED? No

4-1064 27077 N/A 10/6/00 P 17 1/5" P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1065 20873 N/A 10/6/00 P 15 3/4 P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1066 27094 N/A 10/6/00 P 16 3/8" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

Page 98: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S VISUAL T

REPLACE- INSPECT A

TAG# SERIAL# MENT S/N DATE T

4-10671 27097 I N/A

S S S FUNCTIONAL T T HAND- T

INSPECT A A STROKE A

DATE T L DIMEN T ? T

P 171/2 fP Yes P

VISUAL SUMMARY

PERFORMED VISUAL/HANOSTROKE. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3

FUNCTIONAL TEST SUMMARY

FUNCTIONAL TEST PERFORMED? No

I I I- I- I. 4-1068 27085 N/A 10/6/00 P 17 7/16" P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1069

4-1071

10033 N/A 10/1/00 P

1 4 � 416247 N/A 10/2/00 1,, P

27"

20 3/4"

P

P

Yes

Yes

P

P

PERFORMED VISUAL, REMOVED FOR HANDSTROKE. LUBRICATED LOAD PINS AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3. REINSTALLED SNUBBER.

PERFORMED VISUAL/HANDSTROKE. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3. LOOSE PIPE CLAMP. CR 00-1758 WRITTEN TO TIGHTEN/ADJUST PIPE CLAMP

FUNCTIONAL TEST PERFORMED? No

FUNCTIONAL TEST PERFORMED? No

Page 99: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S S

VISUAL T FUNCTIONAL T REPLACE- INSPECT A INSPECT A

TAG# SERIAL# MENT SIN DATE T DATE T

4-1073 3941 N/A 10/2/00 P

L DIMEN

21 9/16E

S S T HAND- T A STROKE A T ? T

"i - T-Y'sF -p,.VISUAL SUMMARY

PERFORMED VISUAL/HANDSTROKE. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3

FUNCTIONAL TEST SUMMARY

FUNCTIONAL TEST PERFORMED? No

4-1075 19297 N/A 9/30100 P 15 3/4" P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1076 24414A N/A 9/30/00 P 13" P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1077 18014 N/A 9/30/00 P 13 1/4" P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

Page 100: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

S VISUAL T

REPLACE- INSPECT A

TAG# SERIAL# MENT S/N DATE T

4-1079 [23227 [- N/A J9/30/00 [

S FUNCTIONAL T

INSPECT A DATE T

L DIMEN

S S T HAND- T A STROKE A T ? T

-1 .21,1/16. f *P - rYes F P- i

VISUAL SUMMARY

PERFORMED VISUAL/HANDSTROKE. LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

FUNCTIONAL TEST SUMMARY

FUNCTIONAL TEST PERFORMED? No

4-1080 24431 N/A 9/30/00 P 11 3/4" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1081 19295 N/A 10/1/00 P 15 15/16" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1082 19296 N/A 10/1/00 P 17 11/16" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3

Page 101: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT

OUTAGE SUMMARY REPORT

UNIT 4 2000 CYCLE 19 REFUELING OUTAGE WO # 30011986

TAG# SERIAL#

VISUAL REPLACE- INSPECT MENT S/N DATE

24408 A I -. N/A J I.10/1/00

S T A T

S S S FUNCTIONAL T T HAND- T

INSPECT A A STROKE A DATE T L DIMEN T ? T

P 1 .4 1/8 [ P Yes P

VISUAL SUMMARY

... .. .. ......................

PERFORMED VISUAL/HANDSTROKE LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3

FUNCTIONAL TEST SUMMARY

FUNCTIONAL TEST PERFORMED? No

1 I I4 I I-I I-I4-1084 23229 N/A 10/1100 P 12 7/8" P Yes P PERFORMED VISUAL/HANDSTROKE. FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3.

4-1085 33622 N/A 10/1/00 P 10 7/16" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No

LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH NEOLUBE #24982-3

4-1100 N/A 10/1/00 P 10 5/8" P Yes P PERFORMED VISUAL/HANDSTROKE FUNCTIONAL TEST PERFORMED? No LUBRICATED LOAD PIN AND SPHERICAL BEARINGS WITH

NEOLUBE #24982-3.

Page 102: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT UNIT 4

2000 REFUELING OUTAGE

SUMMARY OF INSERVICE INSPECTION EXAMINATIONS

Page 103: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (00RF)

CLASS 1 PCBNA STATUS CCOPONENTS

REACTOR PRESSURE VESSEL

ZONE NUMBER: 4-001

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

ASME

SEC. XI

CATEGY ITEM NO

EXAM METHOD

N S O T R A E

PROCEDURE T C

I N S I G

G E 0 H

0 T H E R

REMARKS

"**CALIBRATION BLOCK**

(REF. DWG. NO. 5614-M-4000)

011795 VESSEL TO CLOSURE HEAD B-N-I

SURFACE ON HEAD B13.10

VT-3 4.3-19 C X - - - 10/11/00 - VT3 Completed

(REF. DWG. NO. 5614-M-4001)

023520 4-CH-S-21 THRU 40

RPV STUDS

029320 4-CH-N-21 THRU 40

RPV NUTS

B-G-1 MT 2.2-1 & 2.2-2

B6.30 UT 5.8-1

B-G-1 MT 2.2-3 & 2.2-4

B6.10 UT 5.10-1

CX - -

X - -

CX - -

X - - -

10/03/00 - MT Completed

10/03/00 - UT Completed

**UT-11**

10/03/00 - MT Completed

10/03/00 - UT Completed

**UT-25**

035020 4-CH-LW 21 THRU 40

RPV LARGE WASHERS

040820 4-CH-SW-21 THRU 40

RPV SMALL WASHERS

B-G-1

B6.50

B-G-1

B6.50

VT-i

VT-1

4.1-10

4.1-11

C X - - - 10/03/00 - VT1 Completed

C X - - - 10/03/00 - VT1 Completed

PAGE: 1

Page 104: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 2

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOQD PERIOD, THIRD OUTAGE (0ORF)

CLASS 1 PCBER STATUS COMPONENTS

STEAM GENERATOR B PRIMARY SIDE

ZONE NUMBER: 4-004

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

ASME

SEC. XI CATEGY ITEM NO

EXAM METHOD

N I 0 S O N G T T R S E H A E I 0 E

PROCEDURE T C G M R

REMARKS "tt

CALIBRATION BLOCK**

(REF. DWG. NO. 5614-M-4004)

052000 4-SGB-I BOLTING B-G-2

STEAM GENERATOR INLET B7.30

MANWAY BOLTING

052100 4-SGB-O BOLTING B-G-2

STEAM GENERATOR OUTLET B7.30

MANWAY BOLTING

VT-I 4.1-12

VT-I 4.1-13 & 4.1-14

CX - -

CX - - -

10/07/00 - VT1 Completed

10/07/00 - VTI Completed (Studs

#1 thru #10 and #12 thru #16)

10/08/00 - VT1 Completed (#11)

Page 105: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (CORF)

CLASS 1 PCBEA STATUS COMPONENTS

PRESSURIZER

ZONE NUMBER: 4-006

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

ASME

SEC. XI CATEGY ITEM NO

EXAM METHOD

N S 0 T R A E

PROCEDURE T C

I N S I G

G E 0 M

0 T H E R

REMARKS

**CALIBRATION BLOCK" *

(REF. DWG. NO. 5614-M4-4002)

054300 4-PLW-2 B-B

UPPER SHELL LONG SEAM B2.12

054400 4-PCW-7

UPPER SHELL TO HEAD

054600 SAFETY NOZZLE

SAFETY NOZZLE INSIDE

RADIUS SECTION

054800 SAFETY NOZZLE

SAFETY NOZZLE INSIDE

RADIUS SECTION

055000 SAFETY NOZZLE

SAFETY NOZZLE INSIDE

RADIUS SECTION

055200 RELIEF NOZZLE

RELIEF NOZZLE INSIDE

RADIUS SECTION

055400 SPRAY NOZZLE

SPRAY NOZZLE INSIDE

RADIUS SECTION

B-B

B2.11

B-D

B3.120

B-D

B3.120

B-D

B3.120

B-D

B3.120

B-D

B3.120

UT 5.1-1

UT 5.1-1

C X - - - 10/05/00 - UT Completed **UT-6**

CX -

UT 5.13-1

UT 5.13-2

UT 5.13-3

UT 5.13-4

UT 5.13-5

- - 10/05/00 - UT Completed **UT-8**

CX - - - 10/04/00 - UT Completed **UT-8**

C X - - - 10/04/00 - UT Completed **UT-8**

C X - - - 10/04/00 - UT Completed **UT-B**

C X - - - 10/04/00 - UT Completed **UT-8**

C X - - - 10/04/00 - UT Completed **UT-B**

PAGE: 3

Page 106: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICN INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OGRF)

CLASS 1 PCBEA STATUS COMPONENTS

REACTOR COOLANT SYSTEM PRESSURIZER SURGE LINE

ZONE NUMBER: 4-016 ASME N I 0

SEC. XI S O N G T SUMMARY EXAMINATION AREA CATEGY EXAM T R S E H A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

(REF. DWG. NO. 5614-P-766-S SH. 2)

PAGE: 4

REMARKS "*CALIBRATION BLOCK**

062710 SR-400

SPRING HANGER

F-A

Fl. 10

VT-3 4.3-12 C X - - - 10/01/00 - VT3 Completed

Page 107: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 1 PCBEA STATUS COMPONENTS

REACTOR COOLANT SYSTEM PRESSURIZER SAFETY LOOP A

ZONE NUMBER: 4-017 AS

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

SEC. XI

CATEGY EXAM ITEM NO METHOD

N I S 0 N T R S A E I

PROCEDURE T C G

0 G T E H 0 E M R

REMARKS "**CALIBRATION BLOCK**

(REF. DWG(. NO. 5614-P-564-S SR. 3)

063300 4"-RC-1401-1A

NOZZLE TO SAFE-END

064250 4"-RC-1401-FB B-G-2

PIPING FLANGE BOLTING B7.50

B-F PT 3.3-8

B5.40 RT 9.3-1

VT-1 4.1-7

CX - -

X

Cx - - -

10/01/00 - PT Completed

10/02/00 - RT Completed

(Acceptable rounded indications

recorded in area 0 to 4 1/2) **NOZZLE - TBD, UT-53**

9/30/00 - VTl Completed

PAGE: 5

Page 108: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SU.4WARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 1 PCBEA STATUS COMPONENTS

REACTOR COOLANT SYSTEM PRESSURIZER SAFETY LOOP B

ZONE NUMBER: 4-018 ASHE N I 0

SEC. XI S O N G T SUMMARY EXAMINATION AREA CATEGY EXAM T R S E H A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

(REF. DWG. NO. 5614-P-564-S SH. 3)

064400 4"-RC-1402-lA

NOZZLE TO SAFE-END

B-F PT 3.3-9

B5.40 RT 9.3-2C - - X

X - - -

PAGE: 6

REMARKS

"**CALIBRATION BLOCK**

10/01/00 - PT Completed

(Acceptable Indications)

10/02/00 - RT Completed

10/01/00 - RT Completed **NOZZLE

- TBD, UT-53**

065350 4"-RC-1402-FB B-G-2

PIPING FLANGE BOLTING B7.50

VT-I 4.1-8 C X - - - 9/30/00 - VTl Completed

DATE: 01/04/01

REVISION: 0

Page 109: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 1 PCBEA STATUS COMPONENTS

REACTOR COOLANT SYSTEM PRESSURIZER SAFETY LOOP C

ZONE NUMBER: 4-019 ASME

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

SEC. XI CATEGY ITEM NO

EXAM METHOD

N I 0 S 0 N G T T R S E H A E I 0 E

PROCEDURE T C G M R

(REF. DWG. NO. 5614-P-564-S SH. 2)

065500 4"-RC-1403-1A

NOZZLE TO SAFE-END

B-F PT 3.3-7

B5.40 RT 9.3-3C - - - X

X

REMARKS

"*CALIBRATION BLOCK**

10/01/00 - PT Completed

(Acceptable Indications)

10/02/00 - RT Completed

(Acceptable tungston reported in

area 6 1/2 to 10 1/2, ID surface

in area 10 1/2 to 13 1/2 and ID

surface in area 13 1/2 to 0)

10/01/00 - RT Completed **NOZZLE

- TBD, UT-53**

066450 4"-RC-1403-FB B-G-2

PIPING FLANGE BOLTING B7.50

VT-1 4.1-9 C x - - - 9/30/00 - VT1 Completed

PAGE: 7

Page 110: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (0ORF)

CLASS 1 PCBEA STATUS CCbfPONENTS

REACTOR COOLANT SYSTEM PRESSURIZER SPRAY TO PRZ.

ZONE NUMBER: 4-020 ASME

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

SEC. XI CATEGY EXAM ITEM NO METHOD

N I S O N T R S A E I

PROCEDURE T C G

0 G T E H 0 E M R

REMARKS

"**CALIBRATION BLOCK**

(REF. DWG. NO. 5614-2-566-S SH. 1)

068750 4-RCH-6

SPRING HANGER

069600 4"-RC-1404-31

SAFE-END TO NOZZLE

F-A VT-3 4.3-15

Fl. 10

B-F PT 3.3-5

B5.40 RT 9.3-4

Cx - - -

C X - -

-- X

10/02/00 - VT3 Completed

10/01/00 - PT Completed

10/02/00 - RT Completed

(Acceptable 1/16 rounded

indication reported in area 13

1/2 to 16 1/2) **UT-53**

PAGE: 8

Page 111: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SZCOND PERIOD, THIRD OUTAGE (00RF)

CLASS 1 PCBDA STATUS CCMPONENTS

REACTOR COOLANT SYSTEM PRESSURIZER RELIEF LINE

ZONE NUMBER: 4-022 ASmr

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

SEC. XI CATEGY EXAM ITEM NO METHOD

N I S O N T R S A E I

PROCEDURE T C G

0 G T E H 0 E M R

REMARKS

**CALIBRATION BLOCK**

(REF. DWG. NO. 5614-P-564-S SH. 1)

076700 4"-RC-1406-1.A

NOZZLE TO SAFE-END

077450 4-RCH-4

SPRING HANGER

B-F PT 3.3-6

B5.40 RT 9.3-5

F-A

Fl. 10

VT-3 4.3-13

CX - -

X

C X - - -

10/01/00 - PT Completed

10/02/00 - RT Completed

(Acceptable 1/16" tungston

reported in area 6 to 10 1/2)

**NOZZLE - TBD, UT-53**

9/30/00 - VT3 Completed

PAGE: 9

Page 112: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (CORF)

CLASS 1 PCBDA STATUS COMPONENTS

REACTOR COOLANT PUMP A

ZONE NUMBER: 4-056

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

ASME

SEC. XI CATEGY ITEM NO

EXAM METHOD

N I 0 S O N G T T R S E H A E I 0 E

PROCEDURE T C G M R

REMARKS

"**CALIBRATION BLOCK**

(REF. DWG. NO. 5614-M-4006)

196900 4-RCP-FSA-1 THRU 24 B-G-1

FLANGE STUDS B6.180

UT 5.8-2 C K - - - 10/07/00 - UT Completed

**UT-18**

PAGE: 10

Page 113: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 11

INSERVICZ INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 1 PCEA STATUS COIMPONENTS

CHEMICAL & VOLUME CONTROL, REGENERATIVE HEAT EXCH

ZONE NUMBER: 4-059 ASME

SUbftARY EXAMINATION AREA NUMBER IDENTIFICATION

SEC. XI CATEGY ITEM NO

EXAM METHOD

N I 0 S O N G T T R S E H A E I 0 E

PROCEDURE T C G M R

REMARKS "tt

CALIBRATION BLOCK**

(REF. DWG. NO. 5614-M-4009)

199290 RGX 4E200

VISUAL FOR LEAKAGE

VT-2 4.2-2 VT-3 4.3-11

CX - -X - - -

09/25/00 - VT3 Completed

10/21/00 - VT-2 Completed

Page 114: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICZ INSPECTION SUMOMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 2 PCBSA STATUS COMPONENTS

STEAM GENERATOR B SECONDARY SIDE

ZONE NUMBER: 4-061 ASME N I 0

SEC. XI S O N G T SUMMARY EXAMINATION AREA CATEGY EXAM T R S E H A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

(REF. DWG. NO. 5614-M-4004)

PAGE: 12

REMARKS **CALIBRATION BLOCK**

206600 4-SGB-SS

SECONDARY SIDE

EXAMINATION

VISUAL 4.4-1 UT 5.18-1

A X - - - 10/01/00 - Visual Completed X - - - 10/01/00 - UT Thickness

Page 115: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 2 PCEA STATUS COMPONENTS

RESIDUAL HEAT REMOVAL SYSTEM INSIDE CONTAINMENT

ZONE NUMBER: 4-081 ASME

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

SEC. XI

CATEGY EXAM ITEM NO METHOD

N I 0 S 0 N G T T R S E H A E I 0 E

PROCEDURE T C G M R

REMARKS

"**CALIBRATION BLOCK**

(REF. DWG. NO. 5614-P-509-S SH. 2)

233540 8073-H-808-01

DOUBLE ACTING

RESTRAINT

F-A VT-3 4.3-17

F1.20 VT-3 4.3-18A - X - - 10/07/00 - VT-3 Completed

X - - - (CR#00-1787 - Clamp slipping on

pipe and spherical bearings are

painted)

10/10/00 - VT3 Completed after

corrective action.

PAGE: 13

Page 116: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SU)MMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 2 PCBEA STATUS COMPONENTS

HIGH HEAD SAFETY INJECTION OUTSIDE CONTAINMENT

ZONE NUMBER: 4-097 ASME N I 0

SEC. XI S O N G T SUMMARY EXAMINATION AREA CATEGY EXAM T R S E H A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

(REF. DWG. NO. 5614-P-572-S SH. 3)

PAGE: 14

REMARKS "*CALIBRATION BLOCK**

256828 3-SIH-56

DOUBLE ACTING

RESTRAINT

F-A

Fl. 20

VT-3 4.3-9 C - X 09/27/00 - VT3 Completed. CR

00-1693 was written to address

clearance of 0" instead of 1/16"

per drawing. Engineering has

issued a CRN-C-10835 to change

the drawing. Hanger is

acceptable as is.

256829 3-SIH-56 IA

INTEGRAL ATTACHMENT

C-C

C3.20

PT 3.3-1 C X - - - 09/25/00 - PT Completed

(REF. DWG. NO. 5614-P-783-S SH. 1)

257140 4"-SI-2401-52

2" BRANCH CONNECTION

C-F-l

C5.21

257144 4"-SI-2401-53 C-F-I

2" BRANCH CONNECTION C5.21

PT 3.3-2 CX -

PT 3.3-2

- 09/25/00 - PT Completed

C X - - - 09/25/00 - PT Completed

Page 117: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (0ORF)

CLASS 2 PCBEA STATUS CCOMPONENTS

HIGH HEAD SAFETY INJECTION

ZONE NUMBER: 4-098

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

ASME

SEC. XI CATEGY ITEM NO

EXAM METHOD

N I 0 S O N G T T R S E H AS I 0 E

PROCEDURE T C G M R

REMARKS

"**CALIBRATION BLOCK**

(REF. DWG. NO. 5614-P-783-8 SH. 3)

257853 8081-H-003-03

DOUBLE ACTING

RESTRAINT

F-A

Fl. 20

VT-3 4.3-1 C X - - - 09/25/00 - VT3 Completed

(REF. DWG. NO. 5614-P-513-S SH. 1)

257916 CONT PENETRATION P-59 F-A

ANCHOR FI.20

VT-3 4.3-10 C X - - - 09/28/00 - VT3 Complete

PAGE: 15

Page 118: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOID PERIOD, THIRD OUTAGE (OORF)

CLASS 2 PCBNA STATUS CG(PONENTS

MAIN STEAM SYSTEM LOOP A OUTSIDE CONTAINMENT

ZONE NUMBER: 4-102 ASME

SEC. XIN I 0

S O N G TSUMMARY EXAMINATION AREA CATEGY EXAM T R S E H

A E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

(REF. DWG. NO. 5614-P-562-S

REMARKS

"**CALIBRATION BLOCK**

SH. 2)

262300 26"-MSA-2404-2

6" WELDOLET

262400 26"-MSA-2404-3

12" WELDOLET

262500 26"-MSA-2404-4

12" WELDOLET

C-F-2

C5.81

C-F-2

C5.81

C-F-2

C5.81

262550 26"-MSA-2404-5LU C-F-2

LONGITUDINAL SEAM WELD C5.52

MT 2.2-6

MT 2.2-7

C X - - - 10/06/00 - MT Completed

CX

MT 2.2-7

MT 2.2-7 UT 5.2-1

- - 10/04/00 - MT Completed

C X - - - 10/04/00 - MT Completed

CX X -

10/04/00 - MT Completed

10/05/00 - UT Completed

**UT-21**

262600 26"-MSA-2404-5

PIPE TO VALVE

POV-4-2604

263200 14"-MSA-2402-1

12" WELDOLET TO PIPE

C-F-2 MT 2.2-7

C5.51 UT 5.2-1

C-F-2

C5.51

MT 2.2-7

CX - -- - X -

CX - - -

10/04/00 - MT Completed

10/05/00 - UT Completed

**UT-21**

10/04/00 - Completed

PAGE: 16

Page 119: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 2 PCBZA STATUS COMPONENTS

MAIN STEAM SYSTEM LOOP B OUTSIDE CONTAINMENT

ZONE NUMBER: 4-103 ASME

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

SEC. XI

CATEGY ITEM NO

EXAM METHOD

N I 0 S O N G T T R S E H A E I 0 E

PROCEDURE T C G M R

RP EMARKS **CALIBRATION BLOCK**

(REF. DWG. NO. 5614-P-562-S

264250 26"-MSB-2405-lLU C-F-2

LONGITUDINAL SEAM WELD C5.52

264300 26"-MSB-2405-1 C-F-2

PIPE TO PIPE C5.51

264350 26"-MSB-2405-1LD C-F-2

LONGITUDINAL SEAM WELD C5 .52

264400 26"-MSB-2405-2 C-F-2

6" WELDOLET C5.81

264500 26"-MSB-2405-3

12" WELDOLET

C-F-2

C5.81

MT 2.2-5 UT 5.2-2

MT 2.2-5 UT 5.2-2

MT 2.2-5 UT 5.2-2

MT 2.2-5

MT 2.2-8

CX - -

X - -

CX - --- X

CX - -

X - -

cx - - -

Cx - - -

10/06/00 - MT Completed

10/07/00 - UT Completed

**UT-21**

10/06/00

10/07/00

**UT-21**

10/06/00

10/07/00

**UT-21**

MT Completed

UT Completed

MT Completed

UT Completed

10/06/00 - MT Completed

10/04/00 - MT Completed

PAGE: 17

SH. 2)

Page 120: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSURVICZ INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 2 PCBEA STATUS CO(PONENTS

MAIN FEEDWATER SYSTEM LOOP A

ZONE NUMBER: 4-111 ASME N I 0 SEC. XI S O N G T

SUMMARY EXAMINATION AREA CATEGY EXAM T R S E H A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

(REF. DWG. NO. 5614-P-770-S SH. 3)

PAGE: 18

REMARKS

**CALIBRATION BLOCK**

280650 4-FWH-38

SPRING HANGER

F-A

Fl. 20

VT-3 4.3-14 C X - - - 10/02/00 - VT3 Completed

(REF. DWG. NO. 5614-P-557-S SH. 1)

284460 Augmented Exam

FROM NOZZLE RAMP TO 1

PIPE DIA. ON ELBOW

AUG UT AUT001-1 C - - X - 10/5/00 - UT Completed **UT-20,

UT-29**

Page 121: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICZ INSPECTION SUMO4ARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 2 PCBEA STATUS COMPONENTS

MAIN FEEDWAATER SYSTEM LOOP B

ZONE NUMBER: 4-112 ASME N 1 0

SEC. XI S O N G T SUMMARY EXAMINATION AREA CATEGY EXAM T R S E H NUBRA E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

(REF. DWG. NO. 5614-P-558-S SH. 1)

PAGE: 19

REMARKS

"**CALIBRATION BLOCK**

286980 Augmented Exam

FROM NOZZLE RAMP TO 1

PIPE DIA. ON ELBOW

AUG UT AUT001-2 A- - X - 10/06/00 - UT Completed **UT-20,

UT-29**

Page 122: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 2 PCBEA STATUS COMPONENTS

MAIN FEEDWATER SYSTEM LOOP C

ZONE NUMBER: 4-113

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

ASME

SEC. XI

CATEGY ITEM NO

EXAM METHOD

N I 0 S 0 N G T T R S E H A E I 0 X

PROCEDURE T C G M R

REMARKS

"**CALIBRATION BLOCK**

(REF. DWG. NO. 5614-P-789-S SH. 1)

289650 Augmented Exam

FROM NOZZLE RAMP TO 1

DIA. ON ELBOW

AUG UT AUT001-3 A - - X - 10/06/00 - UT Completed **UT-20,

UT-29**

PAGE: 20

Page 123: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 21

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 2 PCBEA STATUS COMPONENTS

MAIN FEEDWATER BYPASS LOOP B

ZONE NUMBER: 4-115 ASME

SEC. XI

SUMMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

(REF. DWG. NO. 5614-P-770-S SH. 2)

N I 0 S 0 N G T T R S E H A E I 0 E T C G M R

REMANBRS **CALIBRATION BLOCK**

290850 7884-R-014-02

DOUBLE ACTING

RESTRAINT

F-A

Fl. 20

VT-3 4.3-16 C X - - - 10/04/00 - VT3 Completed

Page 124: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (O0RF)

CLASS 2 PCBEA STATUS COMPONENTS

RESIDUAL HEAT EXCHANGER A

ZONE NUMBER: 4-117 ASME

SEC. XI S T

SUMMOARY EXAMINATION AREA CATEGY EXAM A

NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T

(REF. DWG. NO. 5614-M-4010)

N 0 R E C

I N S I G

0 G T E H O E M R

REMARKS "**CALIBRATION BLOCK**

292600 4-RHE-A3 C-B

INLET NOZZLE TO SHELL C2.33

VT-2 4.2-1 C X - - - 7/11/00 - VT2 Completed

292900 4-RHE-SPA-2 IA

INTEGRALLY WELDED

ATTACHMENT

C-C

C3. 10

PT 3.3-4 C X - - - 09/22/00 - PT Completed

PAGE: 22

Page 125: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 23

INSERVICZ INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 3 PCBIA STATUS CQtnPONENTS

COMPONENT COOLING WATER SYSTEM TO CCW PUMP C

ZONE NUMBER: 4-122 ASME

SEC. XI SUMMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

(REF. DWG. NO. 5614-P-518-S SH. 9)

N I 0 S O N G T T R S E H A E I 0 E T C G M R

REMARKS **

CALIBRATION BLOCK**

294900 4-ACH-193

SPRING HANGER

294950 4-ACH-193 IA

INTEGRAL ATTACHMENT

F-A

Fl. 30

D-A

D1. 20

VT-3 4.3-6

VT-I

C X - - - 09/25/00 - VT3 Completed

C X - - - 09/25/00 - VT1 Completed4.1-4

Page 126: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 24TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICZ INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 3 PCEEA STATUS COMPONENTS

COMPONENT COOLING WATER SYSTEM FRCN CCW PUMP A

ZONE NUMBER: 4-152 ASHE

SUMMARY NUMBER

EXAMINATION AREA IDENTIFICATION

SEC. XI CATEGY ITEM NO

EXAM METHOD

N I 0 S O N G T T R S E H A E I 0 E

PROCEDURE T C G M R

REMARKS *

*CALIBRATION BLOCK**

(REF. DWG. NO. 5614-P-501-S SH. 1)

314900 4-ACH-188

SPRING HANGER

315000 4-ACH-188 IA

INTEGRAL ATTACHMENT

F-A

Fl. 30

D-A

Dl. 20

VT-3 4.3-5

VT-1

C X - - - 09/25/00 - VT3 Completed

C X - - - 09/25/00 - VT1 Completed4.1-3

Page 127: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 25

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 3 PCBXA STATUS COMPONENTS

CCMPONENT COOLING WATER SYSTEM FROM CCW PUMP B

ZONE NUMBER: 4-155 ASME

SEC. XI

SUhMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

(REF. DWG. NO. 5614-P-501-S SH. 2)

N I 0 S 0 N G T T R S E H AE I 0 E T C G MR

REMARKS

"**CALIBRATION BLOCK**

317800 4-ACH-184

DOUBLE ACTING

RESTRAINT

F-A

Fl. 30

VT-3 4.3-7 C X - - - 09/25/00 - VT3 Completed

317850 4-ACH-184 IA

INTEGRAL ATTACHMENT

D-A

Dl. 20

VT-I 4.1-5 C X - - - 09/25/00 - VT1 Completed

Page 128: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 26

INSERVICE INSPECTION SUMMOARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (0ORF)

CLASS 3 PCEUA STATUS CamPoNENTS

AUXILIARY FEEDWATER SYSTEM PUMP DISCHARGE

ZONE NUMBER: 4-160 ASME

SEC. XI SUM14ARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

(REF. DWG. NO. 5614-P-807-S SH. 4)

N I 0 S 0 N G T T R S E H A E I 0 E T C G M R

REMARKS **CALIBRATION BLOCK**

322800 80117-H-324-07

SINGLE AND DOUBLE

ACTING RESTRAINT

322850 80117-H-324-07 IA

INTEGRAL ATTACHMENT

F-A

Fl.30

D-A

Dl. 20

VT-3 4.3-3

VT-I 4.1-2

C X - - - 09/25/00 - VT3 Completed

C X - - - 09/25/00 - VTI Completed

Page 129: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 27

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SZCOND PERIOD, THIRD OUTAGE (OORF)

CLASS 3 PCBZA STATUS CCUPONENTS

AUXILIARY FEEDWATER SYSTEM PUMP DISCHARGE

ZONE NUMBER: 4-162 ASME

SEC. XI

SUMMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

(REF. DWG. NO. 5614-P-807-S SH. 5)

N 1 0 S O N G T T R S E H A E I 0 E T C G M R

REMARKS **CALIBRATION BLOCK"*

324600 4-CSTH-124

SINGLE ACTING

RESTRAINT

F-A

Fl. 30

VT-3 4.3-4 C X - - - 09/26/00 - VT3 Completed

324610 4-CSTH-124 IA

INTEGRAL ATTACHMENT

D-A

D1.20

VT-I 4.1-6 C X - - - 09/28/00 - VTl Complete

Page 130: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT NUCLEAR PLANT UNIT 4

INSERVICZ INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 3 PCBEA STATUS CCbfPONENTS

AUXILIARY FEEDUATER PUMP SUCTION FRO4 COND.STG.TK.

ZONE NUMBER: 4-163 ASME

SUMMARY NUMBER

EXAMINATION AREA IDENTIFICATION

SEC. XI

CATEGY ITEM NO

EXAM METHOD PROCEDURE

N S O T R A E T C

I N S I G

G E 0 M

0 T H E R

REMARKS **CALIBRATION BLOCK**

(REF. DWG. NO. 5610-P-818-S SH. 3)

326400 80117-H-341-18

SINGLE ACTING

RESTRAINT

F-A

Fl.30

VT-3 4.3-2 C X - - - 09/26/00 - VT3 Completed. CR

No. 00-1725 was issued due to a

drawing discrepancy and the

threaded rod in contact with a

u-bolt. An engineering

evaluation showed the condition

to be acceptable. Engineering

has issued drawing change

(CRN-C-10834) to r

326450 80117-H-341-18 IA

INTEGRAL ATTACHMENT

D-A

Dl. 20

VT-I 4.1-1 C X - - - 09/26/00 - VT1 Completed

DATE: 01/04/01

REVISION: 0

PAGE: 28

Page 131: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 29

INSERVICE INSPECTION SUMMARY

THIRD INTERVAL, SECOND PERIOD, THIRD OUTAGE (OORF)

CLASS 3 PCBZA STATUS COMPONENTS

INTAKE COOLING WATER FRCM CCW HEAT EXCHANGERS

ZONE NUMBER: 4-167 ASME

SEC. XI

SUM4ARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

(REF. DWG. NO. 5614-P-810-S SH. 1)

N I 0 S O N G T T R S E H A E I 0 E T C G M R

REMARKS

**CALIBRATION BLOCK**

330100 8046-H-190-10

SINGLE ACTING

RESTRAINT

F-A

Fl. 30

VT-3 4.3-8 C X - - - 09/27/00 - VT3 Completed

Page 132: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT UNIT 4

2000 REFUELING OUTAGE

SUMMARY OF IWE EXAMINATIONS

Page 133: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 1IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-001 ASME N I 0

SEC. XI S O N G T T R S E H

SUMMARY EXAMINATION AREA CATEGY EXAM A E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO.

REMARKS **CALIBRATION BLOCK**

410000 CONTAINMENT LINER

LINER PLATE-GENERAL

VISUAL

E-A

El.11

GENERAL 4.7-21 C X - - - 10/06/00 - General Visual

Completed

14 to 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

410010 PENETRATION #1 E-A

RESID.HT.REMOVAL TYPEI E1.11

DETAIL3

PENETRATION #2 E-A

RESID.HT.REMOVAL TYPEI E1.11

DETAIL3

PENETRATION #3

R/C COOLING IN TYPEI

DETAIL3

E-A

El.11

GENERAL 4.7-10

GENERAL------- 4.7....- 10...

GENERAL 4.7-10

GENERAL 4.7-10

CX - -

CX - -

CX - - -

9/30/00

Completed

9/30/00

Completed

9/30/00

Completed

General Visual

General Visual

General Visual

14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

410040 PENETRATION #4 E-A

R/C COOLING OUT TYPEI E1.I1

DETAIL3

410050 PENETRATION #5

PZR RELIEF TANK VENT

TYPEV DETAIL12

410060 PENETRATION #6

PZR RELIEF TANK N2

SUPPLY TYPEV DETAIL12

E-A

E1.11

E-A

El.11

GENERAL 4.7-10

GENERAL 4.7-10

GENERAL 4.7-10

C X - -

CX - - -

C X - - -

9/30/00

Completed

9/30/00

Completed

9/30/00

Completed

General Visual

General Visual

General Visual

410020

410030

Page 134: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-001 ASME N

SEC. XI S 0

SUMMARY EXAMINATION AREA CATEGY EXAM T R A E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C

14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO.

I N S I G

G E 0 M

0 T H E R

REMARKS **CALIBRATION BLOCK**

410070 PENETRATION #7 E-A

PZR RELIEF TANK H20 E1.11

DEMIN. TYPEI DETAIL3

410080 PENETRATION #8 E-A

PZR STEAM SPACE SAMP. ElI.I

TYPEIV DETAIL9

410090 PENETRATION #9 E-A

PZR LIQUID SPACE SAMP. E1.11

TYPEIV DETAIL9

410100 PENETRATION #10

R/C DRAIN TANK VENT

TYPEI DETAIL3

410110 PENETRATION #11

LOW HEAD SAFTEY INJ.

TYPEI DETAIL3

410120 PENETRATION #12

EXCESS LETDOWN HX IN

TYPEI DETAIL3

410130 PENETRATION #13

EXCESS LETDOWN HX OUT

TYPEI DETAIL3

410140 PENETRATION #14

LETDOWN TO NON REGEN

HX TYPEI DETAIL3

E-A ElI.11

E-A

El.11

E-A

E1.11

E-A

E1.11

E-A

El. 11

GENERAL 4.7-11

GENERAL 4.7-10

GENERAL 4.7-10

GENERAL 4.7-11

GENERAL 4.7--1-0

GENERAL 4.7-10

GENERAL 4.7-10

GENERAL 4.7-10

CX 10/01/00

Completed

C X - - - 9/30/00

Completed

CX --

CX --

CX --

CX - -

CX - -

CX - - -

9/30/00

Completed

10/01/00

Completed

9/30/00

Completed

9/30/00

Completed

9/30/00

Completed

9/30/00

Completed

General Visual

General Visual

General Visual

General Visual

General Visual

General Visual

General Visual

General Visual

PAGE: 2

Page 135: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 3lWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (00RF)

CLASS PCBERA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-001 ASME N

SEC. XI S O T R

SUMMARY EXAMINATION AREA CATEGY EXAM A E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C

14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO.

I N S I G

G E 0 M

0 T H E R

REMARKS **CALIBRATION BLOCK**

410150 PENETRATION #15

CHARGING TO REGEN HX

TYPEI DETAIL3

410160 PENETRATION #16

SPARE TYPEI DETAIL3

410170 PENETRATION #17

SAFETY INJ. TEST &

PURGE TYPEI DETAIL3

E-A

El.11

E-A

El. 11

E-A

E1 .11

410180 PENETRATION #18 E-A

SAFETY INJECTION TYPEI E1.11

DETAIL3

410190 PENETRATION #19 ( 2)

CONTAINMENT SPRAY

TYPEI DETAIL3

410200

410210

PENETRATION #20

R/C HOTLEG SAMPLE

TYPEIV DETAIL9

PENETRATION #21

VENT COOLER CW LINE

TYPEI DETAIL3

E-A

E1.11

E-A

El. 11

E-A

E1.11

410220 PENETRATION #22 E-A

VENT COOLER CW RETURN E1.-1

TYPEI DETAIL3

GENERAL 4.7-8

GENERAL 4.7-11

GENERAL 4.7-11

GENERAL 4.7-11

GENERAL 4.7-8

GENERAL 4.7-8

GENERAL 4.7-11

GENERAL 4.7-8

CX - - - 9/30/00

Completed

CX - -

CX - -

CX--

CX - -

CX - -

CX - -

CX - - -

10/01/00

Completed

10/01/00

Completed

10/01/00

Completed

9/30/00

Completed

9/30/00

Completed

10/01/00

Completed

General Visual

General Visual

General Visual

General Visual

General--------Visual---General Visual

General Visual General Visual

9/30/00 - General Visual

Completed

Page 136: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 4IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (O0RF)

CLASS PCBBA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-001 ASME

SEC. XI SUMMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

N I 0 S O N G T T R S E H A E I 0 E T C G M R

REMARKS **CALIBRATION BLOCK**

410230 PENETRATION #23 E-A

CONT SUMP PUMP/HOLD UP El 11

TYPEI DETAIL3

410240 PENETRATION #24 (3)

CHARGEPUMP DIS TO RC

PUMP TYPEI DETAIL3

E-A

El 11

410250 PENETRATION #25 E-A

COOLANTPUMP DIS TO RC E1.11

PUMP TYPEI DETAIL3

410260 PENETRATION #31

RC DRAIN TK H2 ANAL

TYPEIV DETAIL9

410270

410280

PENETRATION #32

CONT AIR SAMPLE IN

TYPEI DETAIL3

PENETRATION #33

CONT AIR SAMPLE OUT

TYPEI DETAIL3

410290 PENETRATION #37

PLUGGED W/CONCRETE

TYPEVI DETAIL13

410300 PENETRATION #43

R/C PUMP CW OUTLET

TYPEI DETAIL3

E-A

E1 .11

E-A El1.11

E-A

E1 .11

E-A

E1 .11

E-A

El.11

GENERAL 4.7-11

GENERAL 4.7-8

GENERAL 4.7-11

GENERAL 4.7-11

GENERAL 4.7-11

GENERAL 4.7-11

GENERAL 4.7-11

GENERAL 4.7-9

CX - - - 10/01/00

Completed

CX - -

CX --

CX - -

CX - -

C X - -

CX - -

CX - - -

9/30/00

Completed

10/01/00 Completed

10/01/00

Completed

10/01/00 Completed

10/01/00

Completed

10/01/00

Completed

10/01/00

Completed

General Visual

General---------Visual----

General Visual

General Visual

General---------Visual----General Visual

General Visual

General Visual

General Visual

General Visual

Page 137: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (0ORF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-001 ASME

SEC. XI SUMMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

N S 0 T R A E T C

I N

S I G

G E

0 M

0 T H E R

REMARKS **CALIBRATION BLOCK**

410310 PENETRATION #44 (3)

CW TO EMERG CONT

COOLERS TYPEI DETAIL3

410320 PENETRATION #45 (3)

CW FROM EMERG CONT

COOLERS TYPEI DETAIL3

410330 PENETRATION #51

SPARE TYPEI DETAIL3

410340 PENETRATION #52

R/C DRAIN TANK DISCH.

TYPEI DETAIL3

410350 PENETRATION #64B

S/G SAMPLE TYPEV

410351 PENETRATION #66A

SPARE

410355 PENETRATION #64C

STEAM GEN SAMPLE

410356 PENETRATION #66B

SPARE

E-A

E1.11

E-A

El.11

E-A

El.11

E-A

El.11

(2) E-A

El. 11

(2) E-A

El.11

E-A

El.f11

E-A

E1.11

GENERAL 4.7-9

GENERAL 4.7-8

GENERAL 4.7---9

GENERAL 4.7-9

GENERAL 4.7-13

GENERAL 4.7-13

GENERAL 4.7-13

GENERAL 4.7-13

C X - - - 10/01/00 - General Visual

Completed

CX - -

CX - -

CX - - -

CX-- --

CX - -

CX - -

CX - - -

9/30/00

Completed

General Visual

10/01/00 - General Visual

Completed

10/01/00

Completed

General Visual

10/1/00 - General Visual

Completed

10/1/00 - General Visual

Completed

10/1/00 - General Visual

Completed

10/01/00 - General Visual

Completed

DATE: 01/04/01

REVISION: 0

PAGE: 5

Page 138: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (00RF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-001 ASME N I 0

SEC. XI S O N G T SUMMARY EXAMINATION AREA CATEGY EXAM T R S E H

A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO.

PAGE: 6

REMARKS

**CALIBRATION BLOCK**

410360 PENETRATION #55

ACCUM. SAMPLE LINE

TYPEIV DETAIL9

E-A

E1.11

GENERAL 4.7-9 C X - 10/01/00 - General Visual

Completed

14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

410370 PENETRATION #56 E-A

SPARE TYPEI DETAIL3 EBll

GENERAL 4.7-9 CX - - - 10/01/00 - General Visual

Completed

14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

410390 PENETRATION #59 E-A

HIGH HEAD INJ. TO LOOP E1.11

B TYPEI DETAIL3

410400 PENETRATION #60 E-A

HIGH HEAD INJ. TO LOOP El.11

C TYPEI DETAIL3

410410 PENETRATION #61B E-A

PZR DEAD WEIGHT TESTER E1.11

TYPEVI DETAIL13

410420 PENETRATION #61A E-A

SPARE TYPE I DETAIL3 E1.11

410430 PENETRATION #63 E-A

INSTR. AIR BLEED TYPEI E1.l1

DETAIL3

GENERAL 4.7-8

GENERAL 4.7-9

GENERAL 4.7-9

GENERAL 4.7-12

GENERAL 4.7-8

CX - -

CX - -

CX - -

CX - -

CX - - -

9/30/00 - General Visual

Completed

10/01/00 - General Visual

Completed

10/01/00 - General Visual

Completed

10/01/00 - General Visual

Completed . Weld is partially

hidden behind concrete platform.

9/30/00 - General Visual

Completed

Page 139: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 7IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-001 ASME

SEC. XI SUMMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

14 TO 74 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

N S 0 T R A E T C

I N

S I G

0 G T E H 0 E M R

REMARKS

**CALIBRATION BLOCK"

410440 PENETRATION #64 A

S/G SAMPLE TYPEI

DETAIL3

410740 PENETRATION #33

BOLTING (PENETRATION

33 TYPEI DETAIL3 )

E-A

E1.11

E-G

EB.10

410910 LINER PLATE @ AZIMUTH E-C

VISIBLE SURFACES E4.11

410930 MOISTURE BARRIER

LINER PLATE TO FLOOR

(MOISTURE BARRIER)

E-D

E5.30

GENERAL 4.7-13

VT-1 4.7-27

VT-I 4.7-35

VT-3 4.7-16

C X - - - 10/01/00 - General Visual

Completed

CX - -

C- X - -

C - X - -

10/07/00 - VT1 Completed

10/07/00 - VTI Complete

Blistered coating has signs of

repeated wetting .

CR-00-1881 generated.

Wetting caused by condensation

due to containment air

conditioning

Repair of blistered coating is

addressed in PMAI

#PMOO-10-111.

10/04/00 - VT3 Completed 1

1/2" x 5" gap lacated between

the concrete floor and a steel

angle is holding water.

CR#00-1817 generated. Steel

angle is part of the containment

air test system and is no longer

in service.

Page 140: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-002 ASME N I 0

SEC. XI S O N G T T R S E H

SUMMARY EXAMINATION AREA CATEGY EXAM A E I 0 E A E 1 0 E

NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

74 TO 134 DEGREES AT 14' TO 39'6" (REF. DWG. NO.

REMARKS **CALIBRATION BLOCK**

410940 CONTAINMENT LINER E-A

LINER PLATE-GENERAL E1.11

VISUAL

GENERAL 4.7-26 C X - - - 10/07/00 - General Visual

Completed

PAGE: 8

Page 141: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

METALLIC CONTAINMENT LINER

PAGE: 9IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (O0RF)

CLASS PCBEA STATUS COMPONENTS

ZONE NUMBER: 4-003 ASME N I O

SEC. XI S O N G T T R S EE

SUMMARY EXAMINATION AREA CATEGY EXAM A E I 0 E A E 1 0 E

NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

134 TO 194 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

411030 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

411040 PENETRATION 40

EQUIPMENT HATCH

(GENERAL VISUAL)

E-A

El.11

E-A

El.11

GENERAL 4.7-25

GENERAL 4.7-45

C X - - - 10/07/00 - General Visual

Completed

C X - - - 10/02/00 - General Visual

Completed

REMARKS

**CALIBRATION BLOCK**

Page 142: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 10IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-004 ASME

SEC. XI SUMMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

194 TO 254 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

N I 0 S O N G T T R S E H A E I 0 E T C G M R

REMARKS "*CALIBRATION BLOCK**

411120 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

411130 PENETRATION 28 (3)

S/G BLOWDOWN SPECIAL

DETAIL15

411140 PENETRATION 29

INSTRUMENT AIR TYPE I

DETAIL3

411150 PENETRATION 29

BOLTING (INSTRUMENT

AIR TYPE I DETAIL3)

411160 PENETRATION 30

SPARE TYPE I DETAIL3

E-A

El 11

E-A

E1 .11

E-A

E1 .11

E-G

E8 .10

E-A

E1 .11

411170 PENETRATION 30 BOLTING E-G

BOLTING (SPARE TYPE I E8.I0

DETAIL3)

411180 PENETRATION 65 A

CONT. ITEGRETY&LEAK

RATE TYPE I DETAIL3

411185 PENETRATION 65 B

CONT. ITEGRETY&LEAK

RATE TYPE I DETAIL3

E-A

E1 .11

E-A

El. 11

GENERAL 4.7-24

GENERAL 4.7-7

GENERAL 4.7-7

VT-i 4.7-19

GENERAL 4.7-7

VT-1 4.7-19

GENERAL 4.7-33

GENERAL 4.7-33

CX - - - 10/07/00

Completed

CX - -

CX - -

CX - -

CX - -

CX - -

CX - -

CX - - -

9/30/00

Completed

9/30/00

Completed

General Visual

General Visual

General Visual

10/05/00 - VT1 Completed

9/30/00 - General Visual

Completed

10/05/00 - VTl Completed

9/30/00 - General Visual

Completed

9/30/00 - General Visual

Completed

Page 143: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION:

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-004 ASME

SEC. XI SUMMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

194 TO 254 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

N S 0 T R A E T C

I N S I G

G E 0 M

0 T H E R

PAGE: II

REMARKS

**CALIBRATION BLOCK**

411186 PENETRATION 65 C

CONT. ITEGRETY&LEAK

RATE TYPE I DETAIL3

E-A

E1.11

GENERAL 4.7-33 CX - 9/30/00 - General Visual

Completed

411240 PENETRATION 65 A

BOLTING (PENETRATION

65 A TYPE I )

411245 PENETRATION 65 B

BOLTING (PENETRATION

65 A TYPE I )

411250 PENETRATION 65 C

BOLTING (PENETRATION

65 CTYPE I )

E-G

E8. 10

E-G

E8.10

E-G

E8.10

411260 PENETRATION 65A GASKET E-D

GASKET (PENETRATION E5.20

65A TYPE I )

------------------------------------------------------------

411265 PENETRATION 65B GASKET E-D

GASKET (PENETRATION E5.20

65A TYPE I )

411270 PENETRATION 65C E-D

GASKETS (PENETRATION E5.20

65C TYPE I )

411300 MOISTURE BARRIER

LINER PLATE TO FLOOR

(MOISTURE BARRIER)

E-D

E5.30

VT-1 4.7-32

VT-1 4.7-32

VT-1 4.7-32

VT-3 4.7-31

VT-3 4.7-31

VT-3 4.7-31

VT-3 4.7-20

CX - -

CX - - -

CX - - -

C X - - -

10/06/00 - VT1 Completed

10/06/00 - VTI Completed

10/06/00 - VT1 Completed

10/06/00 - VT3 Completed

C X - - - 10/06/00 - VT3 Completed

C.. X.. - --........ .. ...... .... ....-1- VT3.. .... Co.. .... leted......

C X - - - 10/06/00 - VT3 Completed

C X - -- 10/06/00 - VT3 Completed

IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCBEA STATUS COMPONENTS

0

Page 144: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

IWE UNIT 4 PAGE: 12

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (O0RF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-005

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

ASME N I 0

SEC. XI S O N G T T R S E H

CATEGY EXAM A E I 0 E A E P D E ITEM NO METHOD PROCEDURE T C G M R

REMARKS **CALIBRATION BLOCK**

254 TO 314 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

411310 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

411320 PENETRATION 38B (28)

ELECTRICAL

PENETRATIONS TYPEIII

411330 PENETRATION 41

PERSONNEL AIRLOCK

SPECIAL

411370 PENETRATION 41

SURFACE AREA GRID-MIN

WALL THICKNESS LOC

411380 PENETRATION 41

PERSONNEL AIRLOCK

SEALS SPECIAL

411390 PENETRATION 41

PERSONNEL AIRLOCK

GASKETS SPECIAL

E-A

E1.1i

E-A

El.11

E-A

El. 11

AUG

AUG

E-D

E5. 10

E-D

E5. 20

GENERAL 4.7-23

GENERAL 4.7-5

GENERAL 4.7-5

VOLUMETRI 5.18-XX

VT-3 4.7-1

VT3 4.7-1

C X - - - 10/06/00 - General Visual

Completed

CX - -

CX - -

cx - -

CX - - -

9/30/00 - General Visual

Completed

9/30/00 - General Visual

Completed

9-25-00 - UT THICKNESS

MEASUREMENTS TAKEN FOR

CR#97-1336 & PMAI99-05-163

9/27/00 - VT3 Completed

C X - - - 9/27/00 - VT3 Completed

411400 PENETRATION 41 BOLTING E-G

BOLTING (PEN.41 DIFF. E8.10

PRESSURE GAUGE)

VT-I 4.7-44 CX - - - 10/05/00 - VTlCompleted

Page 145: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (CORF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-005

SUMMARY NUMBER

EXAMINATION AREA

IDENTIFICATION

ASME

SEC. XI CATEGY ITEM NO

EXAM METHOD

N I 0 S O N G T T R S E H A E I 0 E

PROCEDURE T C G M R

REMARKS

"**CALIBRATION BLOCK**

254 TO 314 DEGREES AT 14' TO 39'6" (REF. DW1G. NO.

411410 PENETRATION 41 BOLTING E-G

BOLTING (PEN.41 DIFF. E8.10

PRESSURE VALVE)

VT-1 4.7-44 C X - - - 10/05/00 - VT1 Completed

PAGE: 13

Page 146: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 14IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OGRF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-006 ASME N I 0

SEC. XI S O N G T

SUMMARY EXAMINATION AREA CATEGY EXAM T R S E H A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

314 TO 14 DEGREES AT 14' TO 39'6" (REF. DWG. NO.

REMARKS "**CALIBRATION BLOCK**

411450 LINER PLATE E-A

LINER PLATE (GENERAL EI.ll

VISUAL)

GENERAL 4.7-22 C X - - - 10/06/00 - General Visual

Completed

411460 PENETRATION 38A (28)

ELECTRICAL

PENETRATIONS TYPEIII

E-A

El.11

GENERAL 4.7-6 C X - - - 9/30/00 - General Visual

Completed

314 TO 14 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

411470 PENETRATION 48B (2) E-A

ELECTRICAL PEN. (RC El.11

PUMP) TYPEIII

411475 PENETRATION 48C (2) E-A

ELECTRICAL PEN. (RC E1.11

PUMP) TYPEIII

GENERAL 4.7-34

GENERAL 4.7-34

CX - -

CX - - -

9/30/00 - General Visual

Completed

09-30-00 -GENERAL VISUAL

COMPLETE

314 TO 14 DEGREES AT 14' TO 39'6" (REF. DWG. NO. )

411480 PENETRATION 46 (3) E-A

CONT. PRESSURE INSTR. El.11

TYPEI DETAIL3

GENERAL 4.7-6 CX - - - 9/30/00 - General Visual

Completed

314 TO 14 DEGREES 14' TO 39'6" (REF. DWG. NO. )

411490 PENETRATION 36

CONTAINMENT PURGE

SPECIAL DETAIL2

E-A

El.11

GENERAL 4.7-6 C X - - - 9/30/00 - General Visual

Completed

Page 147: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 15IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (CORF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-007 ASME N I 0

SEC. XI S O N G T T R S E H SUMMARY EXAMINATION AREA CATEGY EXAM A E I E H

A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

14 TO 74 DEGREES AT 39'6" TO 59'6" (REF. DWG. NO.

REMARKS

"**CALIBRATION BLOCK**

411590 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

E-A

El. 11

GENERAL 4.7-36 C X - - - 10/09/00 - General Visual

Completed

Page 148: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (O0RF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-008 ASME N I

SEC. XI S O N T R S

SUMMARY EXAMINATION AREA CATEGY EXAM A R I A R I NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G

74 TO 134 DEGREES AT 39'6" TO 59'6" (REF. DWG. NO.

0 G T E H 0 E M R

PAGE: 16

REMARKS "**CALIBRATION BLOCK**

411630 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

E-A

E1.11

411640 PENETRATION 49 E-A

EMERGENCY ESCAPE HATCH El.11

SPECIAL DETAIL3

GENERAL 4.7-3

GENERAL 4.7-3

C X - - - 9/30/00 - General Visual

Completed

C X - - - 9/30/00 - General Visual

Completed

Page 149: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (ORF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-009 ASME

SEC. XI SUMMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

134 TO 194 DEGREES AT 3916" to 59' 6" (REF. DWG. NO.

N I 0 S O N G T T R S E H A E I 0 E T C G M R

REMARKS "**CALIBRATION BLOCK**

411720 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

E-A

E1.11

GENERAL 4.7-2 C X - - - 9/30/00 - General Visual

Completed

PAGE: 17

Page 150: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (O0RF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-010 ASME

SEC. XI

SUMMARY EXAMINATION AREA CATEGY EXAM

NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

194 TO 254 DEGREES AT 39'6" TO 59'6" (REF. DWG. NO. )

N S O T R A E T C

I N S I G

G E 0 M

0 T H E R

REMARKS **CALIBRATION BLOCK**

411760 LINER PLATE E-A

LINER PLATE (GENERAL EI.11

VISUAL)

GENERAL 4.7-4 C X - - - 9/30/00 - General Visual

Completed

411770 PENETRATION 27 (3)

FEEDWATER SPECIAL

DETAIL4

E-A

El.11

GENERAL 4.7-4 C X - - - 9/30/00 - General Visual

Completed

254 TO 314 DEGREES AT 39'6" TO 59'6" (REF. DWG. NO. )

411775 PENETRATION 26 A

MAIN STEAM SPECIAL

DETAIL4

E-A

E1.11

GENERAL 4.7-4 CX - - - 9/30/00 - General Visual

Completed

DATE: 01/04/01

REVISION: 0

PAGE: 18

Page 151: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-011

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

ASME

SEC. XI CATEGY ITEM NO

EXAM METHOD

N S O T R A E

PROCEDURE T C

I N S I G

G E 0 M

0 T H E R

REMARKS "**CALIBRATION BLOCK**

254 TO 314 DEGREES AT 39'6" TO 59'6" (REF. DWG. NO. )

411820 LINER PLATE E-A

LINER PLATE (GENERAL E1.11

VISUAL)

411830 PENETRATION 48A (4) E-A

R/C PUMP POWER TYPEIII E1.11

DETAIL

411840 PENETRATION 26 B

MAIN STEAM SPECIAL

DETAIL4

411845 PENETRATION 26 C

MAIN STEAM SPECIAL

DETAIL4

E-A

El.11

E-A

El.11

GENERAL 4.7-28

GENERAL 4.7-14

GENERAL 4.7-14

GENERAL 4.7-14

C X - - - 10/06/00 - General Visual

Completed

CX - -

CX - -

cx - - -

10/2/00 - General Visual

Completed

10/2/00 - General Visual

Completed

10-02-00 - GENERAL VISUAL

COMPLETE

PAGE: 19

Page 152: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 20IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCEEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-012 ASME N I 0

SEC. XI S O N G T T R S E H

SUMMARY EXAMINATION AREA CATEGY EXAM A E I 0 E A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

314 TO 14 DEGREES AT 39'6" TO 59'6" (REF. DWG. NO.

REMARKS **CALIBRATION BLOCK**

411900 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

E-A

E1.11

GENERAL 4.7-29 C X - - - 10/06/00 - General Visual

Completed

Page 153: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 21IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (O0RF)

CLASS PCBEA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-013 ASME N I 0

SEC. XI S O N G T T R S E H

SUMMARY EXAMINATION AREA CATEGY EXAM A E I 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

14 TO 74 DEGREES AT 59'6" TO 125-10" (REF. DWG. NO.

REMARKS **CALIBRATION BLOCK**

411940 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

E-A

El.11

GENERAL 4.7-37 C X - - - 10/09/00 - General Visual

Completed

Page 154: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

PAGE: 22IWE UNIT 4

INSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PC!EA STATUS COMPONENTS

METALLIC CONTAINMENT LINER

ZONE NUMBER: 4-014 ASME

SEC. XI SUMMARY EXAMINATION AREA CATEGY EXAM NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE

74 TO 134 DEGREES AT 59'6" TO 125'10" (REF. DWG. NO. )

N I 0 S O N G T T R S E H A E I 0 E T C G M R

REMARKS

"**CALIBRATION BLOCK**

411980 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

E-A

El. 11

GENERAL 4.7-39 C X - - - 10/09/00 - General Visual

Completed

Page 155: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISION: 0

IIU UNIT 4

IMSERVICE INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCBZA STATUS COMPONENTS

METALLIC COWTAI03ENT LINER

ZONE NUMBER: 4-015

SUMMARY EXAMINATION AREA NUMBER IDENTIFICATION

ASME

SEC. XI CATEGY ITEM NO

EXAM METHOD

N I 0 S O N G T T R S E H A E I 0 E

PROCEDURE T C G M R

REM4ARKS

"**CALIBRATION BLOCK**

134 TO 194 DEGREES AT 59'6" TO 125'1O" (REP. DWG. NO.

412020 LINER PLATE E-A

LINER PLATE (GENERAL E1.11

VISUAL)

GENERAL 4.7-38 CX - - - 10/09/00 - General Visual

Completed

PAGE: 23

Page 156: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

R3VI8ION: 0

IWE UNIT 4

INSERVICZ INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCBEA STATUS COMPONENTS

YAgEhLLIC CONTAINMENT LINER

ZONE MISER: 4-016 ASHE N I 0

SEC. XI S O N G T SUMMARY XAMINATION AREA CATEGY EXAM T R S E H A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

194 TO 254 DEGREES AT 59'6" TO 125'10" (REF. DWG. NO.

PAGE: 24

REMARKS

"**CALIBRATION BLOCK**

412060 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

E-A

El.Il

GENERAL 4.7-40 C X - - - 10/09/00 - General Visual

Completed

Page 157: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REVISIGE: 0

INX UNIT 4

INSERVICZ INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCNEA STATUS COMPONENTS

METALLIC =&IUM LIN

ZONE NUMBER: 4-017 ASME N I 0

SEC. XI S O N G T SU1MARY EXAMINATION AREA CATEGY EXAM T R S E H A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

254 TO 314 DEGREES AT 5916" TO 125'10" (REF. DWG. NO.

PAGE: 25

REMARKS

**CALIBRATION BLOCK**

412100 LINER PLATE

LINER PLATE (GENERAL

VISUAL)

E-A

El. 11

GENERAL 4.7-41 C X - - - 10/09/00 - General Visual

Completed

Page 158: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DAWN: 01/04/01

WM8IOw: 0

I=K UNIT 4

INSERVICZ INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (O0RF)

CLASS PCBEA STATUS COMPONENTS

MICALLIC CONTAINMENT LINER

ZONK NtMER: 4-018 ASME N I 0

SEC. XI S O N G T SU)SXY EXAMINATION AREA CATEGY EXAM T R S E H A E 1 0 E NUMB= IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

314 TO 14 DEGREES AT 59'6" TO 12510" (REF. DWG. NO. )

PAGE: 26

REMARKS

"CALIBRATION BLOCK**

412140 LINER PLATE E-A

LINER PLATE (GENERAL EI.11

VISUAL)

GENERAL 4.7-42 C X - - - 10/09/00 - General Visual

Completed

412150 PENETRATION 35

CONTAINMENT PURGE

SPECIAL DETAIL2

E-A

E1.11

412160 PENETRATION 35 BOLTING E-G

BOLTING PENETRATION 35 ES.10

SPECIAL DETAIL2

GENERAL 4.7-18

VT-I 4.7-17

CX - - -

CX - - -

10/04/00 - General Visual

Completed

10/04/00 - VT1 Completed

Page 159: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

DATE: 01/04/01

REISZIZO: 0

== UNIT 4

INSERVICZ INSPECTION SUMMARY

FIRST INTERVAL, FIRST PERIOD, SECOND OUTAGE (OORF)

CLASS PCBDA STATUS COMPONENTS

METALLIC CONTAIMIENT LINER

ZONE NUMBER: 4-019 ASME N I O

SEC. XI S O N G T SU1MMARY EXAMINATION AREA CATEGY EXAM T R S E H A E 1 0 E NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R

0 TO 360 DEGREES 125'10" TO TOP OF DOME (RZF. DWG. NO.

PAGE: 27

REMARKS

"**CALIBRATION BLOCK**

412210 LINER PLATE (DOME) E-A

DOME (GENERAL VISUAL) El.11

GENERAL 4.7-43 C X - - - 10/09/00 - General Visual

Completed

Page 160: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

TURKEY POINT UNIT 4

2000 REFUELING OUTAGE

SUMMARY OF SYSTEM PRESSURE TESTING

Page 161: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Abstract

This report details the pressure testing of selected class 1, 2 and 3 piping and components of the Florida Power and Light Company Turkey Point Unit 4 cycle 19 which were performed prior to and during the fall 2000 refueling outage. This outage occurred between the dates of September 25, 2000 and October 23, 2000, and the testing period covers the dates from April 10, 1999 through October 23, 2000. This pressure testing is being reported following the third outage of the second period for 3rd ten year interval for Turkey Point Unit 4.

Piping and components were selected and tested in accordance with Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code "Rules for Inservice Inspection of Nuclear Power Components", 1989 Edition with no addenda with specific relief as granted under 10 CFR 50.55a.

Page 162: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Procedures

The following Florida Power and Light (FPL) procedures and documents have been implemented to provide instructional guidance for the performance of the required ASME XI pressure testing and subsequent inspections.

4-OSP-041.25 RCS Overpressure Leak Testing

4-OSP-45.1 ASME Section XI Quality Group A Bolting Examination*

4-OSP-45.2 ASME Section XI Quality Group B Bolting Examination*

0-ADM-523 ASME Section XI Pressure Tests for Quality Group A, B, C Systems/Components.

4-OSP-041.2 Reactor Coolant System Visual Leak Inspection and Leak Evaluation.

NDE-4.2 Visual Examination VT-2 Conducted During System Pressure Tests.

*Relief Request No 18, Use of Code Case N-533 Authorized for Turkey Point Units 3 and 4 (TAC NOS. M98149 AND M98150).

Page 163: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

System Summary:

The following safety related Class 1, 2, and 3 systems, or sections thereof were pressure tested in accordance with the requirements of the 1989 ASME Section XI Code.

System Name System Number

Condensate Storage 18

Intake Cooling Water 19

Emergency Diesel 22

Component Cooling Water 30

Spent Fuel pool Cooling 33

Reactor Coolant 41

Chemical and Volume Control 47

Residual Heat Removal 50

Safety Injection 62

Containment Spray 68

Main Steam 72

Feedwater 74

Auxiliary Feedwater 75

Page 164: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Acronyms

ADM: Administrative

ASME: American Society of Mechanical Engineers

CSS: Containment Spray System

CCW: Component Cooling Water

CVCS: Chemical Volume Control System

ECC: Emergency Containment Cooler

FW: Feedwater

HX: Heat Exchanger

ICW: Intake Cooling Water

NDE: Non Destructive Examination

PWO: Plant Work Order

PZR: Pressurizer

RCP: Reactor Coolant Pump

RHR: Residual Heat Removal

RO: Restricting Orifice

RV: Relief Valve

RX: Reactor

SFPC: Spent Fuel Pool Cooling

SG: Steam Generator

WO: Work Order

Page 165: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

Test Package Development

The specific pressure test boundaries were selected after review of the applicable plant Operating diagram/code boundary drawings. The piping systems were broken into sub systems. The sub-systems were selected based on Technical Specifications operability requirements, acceptable isolation points and availability of test connections and vent valves. The sub-systems were then assigned test package numbers, which could be tested in entirety, or based on availability could be broken down further into numerous tests within the specific sub-system.

The pressure test package numbers contain six (6) segments of information,

Sample: 04-CCW-30110-1-01 A A A A A A

1 2 3456

1. Unit Number (00) common to both units 3 and 4. (03) Unit specific. (04) Unit specific.

2. System abbreviation

3. System number [First (2) digits].

4. Sub-system number [(2) or (3) digits].

5. Type of test (H) Hydrostatic, (P) Pneumatic, (L) Leakage, (F) Functional, (I) Inservice, (S) Static head.

Number of test performed within the specific sub-system.6.

Page 166: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

CONDENSATE STORAGE SYSTEM 18

04-CST-1802-F-02 Test Date: 09/21/00

This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

INTAKE COOLING WATER SYSTEM 19

04-ICW-1973-I-02 Test Date: 09/20/00

This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

04-ICW-19103-L-01 Test Date: 10/11/00

This test due to the replacement of valve 4-50-411 under WO# 99005389. No leakage was observed during this test.

04-ICW-191 10-L-01 Test Date: 05/17/00

This test performed due to replacement of piping and valve 4-50-413 vent line, ref WO# 29009888. No leakage was observed during this test.

4-ICW-19111-L-01 Test Date:04/17/00

This test performed due to replacement of valve 4-50-326, Ref WO# 30007432. No leakage was observed during this test.

04-ICW-19104-L-01 Test date: 09/11/00

This test due to replacement of 4C Intake Cooling Water pump, Expansion joint, and 450-331 Check valve under WO# 98014334,98014332, and 30011986. No leakage was observed during this leakage test.

Page 167: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

EMERGENCY DIESEL GENERATOR SYSTEM 22

04-EDG-2203-F-02 Test Date: 10/07/00 This test was performed to meet ASME Section XI 1989 Edition periodic pressure Test requirements. No leakage was observed during this functional test.

04-EDG-2205-F-02 Test Date:09/22/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. Leakage was identified @ 90 Deg elbow thru wall, ref CR# 00-1650

04-EDG-2206-F-02 Test Date: 10/07/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

04-EDG-2207-F-02 Test Date: 10/11/00 This test was performed to meet ASME Section XI 1989 Edition periodic pressure Test requirements. No leakage was observed during this functional test.

04-EDG-2209-F-02 Test Date: 09/22/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

04-EDG-2252-L-01 Test Date: 11/17/00 This pressure being performed due to piping replacement of air start system, on Diesel 4B ref WO# 30019143. No leakage was observed during this test.

04-EDG-2253-L-01 Test Date: 10/22/00 This pressure being performed due to piping replacement of air start system, on Diesel 4A ref WO# 30019132. No leakage was observed during this test.

Page 168: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

COMPONENT COOLING WATER SYSTEM 30

04-CCW-30205-I-02 Test Date: 09/22/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

04-CCW-30206-I-02 Test Date: 09/22/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

04-CCW-30210-I-02 Test Date: 09/22/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

04-CCW-30212-I 02 Test Date: 09/22/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

04-CCW-30324-L-01 Test Date: 10/18/00 This test was performed due to the replacement of RV-4-1431 for the CCW CRDM cooler per WO# 30017904. No leakage was observed during this test.

Page 169: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

COMPONENT COOLING WATER SYSTEM 30 (CONTINUED)

04-CCW-30220-I-02 Test Date: 09/22/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

04-CCW-30224-I-02 Test Date: 09/22/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

04-CCW-30225-I-02 Test Date: 09/22/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

SPENT FUEL POOL COOLING SYSTEM 33

04-CCW-30225-I-02 Test Date: 09/22/00 This test was performed to meet the 1989 Edition of ASME Section XI periodic pressure Test requirements. No leakage was noted during this test.

Page 170: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

REACTOR COOLANT SYSTEM 41

04-RCS-4111-L-03 Test Date 10/21/00

This test involved the leakage test of the Reactor Coolant System piping inside containment following the Unit 4 Cycle 19 Refueling Outage. This leakage test addressed the following replacements.

Component

RV-4-551A RV-4-551B RV-4-551C RV-4-203 4-873A

WO#

30006910 30006911 30006912 98009247 29016612

Replaced

Remove, install spare Remove, install spare Remove, install spare Remove, install spare Remove, install new valve

No leakage was observed during this test.

Page 171: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

CHEMICAL AND VOLUME CONTROL CHARGING AND LETDOWN SYSTEM 47

04-CVCS-4754-I-02 Test date: 09/18/00 This Inservice test was performed to meet the ASME Section XI 1989 Edition periodic Pressure test requirements. No through wall leakage was observed.

04-CVCS-4755-I-02 Test date: 09/18/00 This Inservice test was performed to meet the ASME Section XI 1989 Edition periodic Pressure test requirements. No through wall leakage was observed.

04-CVCS-4756-L-02 Test date: 09/18/00 This Inservice test was performed to meet the ASME Section XI 1989 Edition periodic Pressure test requirements. No through wall leakage was observed.

04-CVCS-4760-I-02 Test date: 09/18/00 This Inservice test was performed to meet the ASME Section XI 1989 Edition periodic Pressure test requirements. No through wall leakage was observed.

04-CVCS-4769-L-01 Test Date: 10/21/00 This test due to welding of the pressure boundary seal weld on valve 4-293A under WO# 30008363. No leakage was observed during this test.

04-CVCS-4770-L-01 Test Date: 10/21/00 This test due to welding of the pressure boundary seal weld on valve 4-293B under WO# 30012451. No leakage was observed during this test.

04-CVCS-4771-L-01 Test Date: 10/21/00 This test due to the replacement of valve 4-333 under WO# 29008421. No leakage was observed during this test.

04-CVCS-4772-L-01 Test Date: 10/10/00 This test due to the replacement of valve 4-353A under WO# 29013107. No leakage was observed during this test.

04-CVCS-4773-L-01 Test Date: 10/21/00 This test due to the replacement of valve 4-1316 under WO# 30015586. No leakage was observed during this test.

Page 172: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

RESIDUAL HEAT REMOVAL SYSTEM 50

04-RHR-5029-02 Test Date: 07/11/00

This Functional pressure test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements.

04-RHR-5030-02 Test Date: 10/10/00

This Functional pressure test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage was observed during this functional test.

Page 173: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

SAFETY INJECTION SYSTEM 62

04-SIS-6232-F-02 Test Date: 07/07/00

This test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage was observed during this functional test.

04-SIS-6233-F-02 Test Date: 07/07/00

This test was performed to meet ASME Section XI 1989 Edition periodic pressure Test requirements. No leakage was observed during this functional test.

04-SIS-6237-L-01 : Test Date: 10/04/00 This test due to replacement of valve 4-873A under WO# 29010612. No leakage was observed during this test.

Page 174: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

CONTAINMENT SPRAY SYSTEM (68)

04-CSS-6814-F-02: Test Date: 10/19/00

This Functional test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No through wall leakage was observed.

Page 175: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

MAIN STEAM SYSTEM 72

04-MS-7204-I-02: Test Date: 09/16/00

This Inservice test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-MS-7205-I-02: Test Date:09/16/00 This Inservice test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-MS-7206-I-02: Test Date: 09/16/00 This Inservice test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

Page 176: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

FEEDWATER SYSTEM 74

04-FW-7425-I-02: Test Date: 09/16/00 This Inservice test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-FW-7426-I-02: Test Date: 09/16/00 This Inservice test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-FW-7427-I-02: Test Date: 09/16/00 This Inservice test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-FW-7431-I-02: Test Date: 09/16/00 This Inservice test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-FW-7432-I-02: Test Date: 09/16/00 This Inservice test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-FW-7433-I-02: Test Date: 09/16/00 This Inservice test was performed to meet ASMIE Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

Page 177: Inservice Inspection Report for Turkey Point Unit 4.examinations. See the attached report: Turkey Point Unit 4 Inservice Inspection Summary and Turkey Point Unit 4 IWE Summary for

AUX FEEDWATER SYSTEM 75

04-AFW-7551-F-02: Test Date: 09/16/00 This Funtional test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-AFW-7552-F-02: Test Date: 09/23/00 This Funtional test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-AFW-7553-F-02: Test Date: 09/23/00 This Funtional test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-AFW-7554-F-02: Test Date: 09/23/00 This Funtional test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-AFW-7555-F-02: Test Date: 09/23/00 This Funtional test was performed to meet ASME Section XI 1989 Edition periodic pressure test requirements. No leakage observed during this test.

04-AFW-7556-F-02 Test Date: 09/23/00 This test was performed to meet ASME Section XI 1989 Edition periodic pressure Test requirements. No leakage was observed during this functional test.