initiation of an igrt program - amos...

24
1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology Mayo Clinic Rochester, MN Acknowledgments Lei Dong Thomas Niedermayr Kathy Kolsky Scott Lacey Debra Brinkmann Initiation of an IGRT Program Define the intended goal Select Equipment Develop clinical protocols Patient Selection Targeting Process QA Training Effectiveness assessment Accuracy Resource allocation

Upload: others

Post on 28-Oct-2019

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

1

Initiation of an IGRT Program

Jon J. Kruse, Ph.D.

Dept. of Radiation Oncology

Mayo Clinic

Rochester, MN

Acknowledgments

• Lei Dong

• Thomas Niedermayr

• Kathy Kolsky

• Scott Lacey

• Debra Brinkmann

Initiation of an IGRT Program

• Define the intended goal

• Select Equipment

• Develop clinical protocols

• Patient Selection

• Targeting Process

• QA

• Training

• Effectiveness assessment

• Accuracy

• Resource allocation

Page 2: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

2

Definition of Program Goal

• Decide what its purpose is (MD guided):

• On-line pre-treatment setup

• Intra-treatment monitoring

• Feeding adaptive treatment protocols

• Choose targeting method (MD/Physics collaboration)

• Bony anatomy

• Soft tissue guidance

• Fiducials

• These items guide equipment selection

Resources for Equipment Selection

• ASTRO White Paper: Assuring Quality and Safety in Image-guided Radiation Therapy To be published in PRO.

• AAPM TG-58: Clinical Use of Electronic Portal Imaging

• AAPM TG-104: The Role of In-Room kV X-Ray Imaging for Patient Setup and Target Localization

• AAPM TG-179 In-room CT Localization

• AAPM TG-147 Non-radiographic Localization

IGRT Systems: Ideal Properties• Accurate, precise

• Explicit interpretation, minimal training, operator independent

• Efficient, integrated

• Rapid

• Integrated with machine for remote intervention

• Broad/Universal application

• Large number of anatomical sites

• Large field of view

• Reduce radiation dose

• non ionizing, or efficient detectors.

• account for imaging dose?

• Real-time

• continuous monitoring

• Images for planning & evaluation

• CHEAP! G. Mageras, Semin. Radiat. Oncol. 2005.

Page 3: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

3

Clinical Example: IGRT for Protons

• Goals:

• Pre-Tx online setup guidance

• Intra-Tx monitoring

• Adaptive planning feedback

• Clinical priorities

• Quick and efficient

• Low dose

Clinical Example: IGRT for Protons

• Treatment Sites (MD defined)

• Head and neck

• Bony Anatomy is a good surrogate

• CNS: Brain and Craniospinal Axis

• Bony Anatomy

• Pelvis: Prostate and Gyn

• Bony Anatomy not great

• Lung

•Want CT localization

Fixed Radiographic System• Fast image acquisition and analysis

• Fast Intra-Tximaging at any gantry/couch position

• Fluoroscopy capable

• Low dose

• Large FOV

Page 4: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

4

CT Localization for Protons: Pelvis

• Change in position of bony anatomy alters

dose distribution

• CT localization may be of limited use

CT Localization for Protons: Lung• Change in position of rib causes minimal

disturbance of dose distribution

• We want CT localization

• Scanning beam treatments – always gated

• Need respiratory correlated CT

• Need reliable HU for adaptive planning

CT on Rails

• 4DCT capable for guidance of gated treatment

• Fast acquisition for single breath hold imaging

• Reliable CT numbers for adaptive planning

Page 5: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

5

Developing Clinical Protocols

• Multi-disciplinary team

• Physicians

• Physicists

• Therapists

• Dosimetrists

• Excellent guidance in ASTRO IGRT White Paper

Issues for IGRT Protocols

• Imaging Parameters

• Image Quality vs. Dose

• Reference Images

• Targeting Process

• Manual or Automatic Match

• Anatomy for Matching

• Regions of Interest

• Documentation!!

• QA

• End to end tests

Imaging Parameters

• Imaging dose, if not managed properly, can be substantial

• Many times a low dose ‘good’ image works as well as a high dose ‘great’ image

• For guidance:

• AAPM TG-75: The management of imaging dose during image-guided radiotherapy

• Consider X-ray Technique: kVp, mAs

• Consider Imaging Volume

Page 6: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

6

Optimizing Reference Images

Optimizing Reference Images

Depth Control used to accentuate critical features

Post Prostatectomy Surgical Clips

Target Identification in Reference Images

Page 7: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

7

Target Identification in Reference Images

•Clips are contoured in CT scan and projected in DRR

•Red for clips within PTV•Blue for clips outside PTV

•Color coding tells therapists which clips to match with, which to ignore

Target Identification in Reference Images

Targeting Process

• Patients are not rigid bodies

• Lots of prominent anatomy that is not correlated with target tissue

• Physicians must describe the target and correlated anatomy

• Therapists should weigh in on the matching process

• What’s visible

• Difficulty

Page 8: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

8

Fraction A

Fraction B

Fraction C

Page 9: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

9

Fraction D

Fraction E

Targeting Process: Automated Algorithms

• Increasing application of automated matching algorithms

• Patients are not rigid bodies

• Lots of prominent anatomy that is not correlated with target tissue

Page 10: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

10

Automated 6DOF Matching

•Masking of non-pertinent anatomy is critical for successful implementation

Documentation• Therapists should have easy access to instructions for every case

• Imaging protocol

• Matching instructions

• Adjustment thresholds

• Adjustment limits

• Re-imaging/Consult thresholds

• Contingency plans

• Language

• Greatly reduces therapist stress levels

• Happy therapists are effective therapists

OBI Instruction Sheet

• Document which anatomical feature is to be matched

• Contingency plan if imager is not available

• Request to be present for 1st day

• Therapists know exactly what to do

Page 11: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

11

Protocols: Language Standardization

• Everyone must agree on a common language for IGRT analysis/adjustment

• What does “shift left 4 mm” mean?

• Critical that Physicians, Physicists, Dosimetrists, and Therapists all speak the same language

QA

• A single IGRT protocol may have many independent parts

• Simulation hardware

• Treatment planning software

• IGRT imagers

• Image analysis software

• Each must be monitored independently to verify proper performance

QA Guidance

• AAPM TG-142: Quality Assurance of Medical Accelerators

• AAPM TG-58: Clinical Use of EPID

• AAPM TG-104: The Role of In-Room kV X-Ray Imaging for Patient Setup and Target Localization

• Many other reports coming

• Manufacturer literature

• Acceptance documents

Page 12: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

12

End-to-End Test

• Simulation, planning, setup, and treatment of a phantom

• Done exactly as a patient would be

• Tests individual components, but also how they interact

• Critical for complex, multi-vendor processes

End To End Example

• We have used up to four software vendors in the planning/IGRT process

• Virtual Sim

• Treatment Planning

• ROIS

• IGRT

• Some manufacturers may make assumptions about data coming from other sources that could lead to errors

• Location of CAX, for example.

QA: “Sanity checks”

• Couch Coordinate Predictions

• Maximum Shift Protocols

• Oversight with another technology (EPID – free imaging)

Page 13: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

13

Couch Coordinate Prediction

• 1 straight, 1 angled wire in sim couch top can be digitized in treatment planning

Couch Coordinate Prediction

• Patients are indexed to couch top – if coordinates are much different from prediction there may be a problem

IGRT “Oversight” with EPID

• Nearly all linacs have an MV EPID

• Lower image quality than OBI/ExacTrac, but can image with the treatment beam with no additional dose to patient

• Imaging along treatment direction, with treatment source

• Verify shifts from radiographic setups, provide sanity checks for CBCT shifts

• Monitor intra-fractional motion

• See TG-58

Page 14: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

14

Training

• Consider developing therapist/physicist experts or ‘protocol champions’ for a given technique

• Disseminate information to rest of clinic through them

• Justification

• Goals

• Processes

Training: Justification for Extra Work

• Distended rectum during sim leads to systematic displacement of prostate during treatment (de Crevoisier, IJROBP 2005)

Repeated With IGRT

• Kupelian et al., Red Journal 70, 2008

• Understanding leads to better enthusiasm and effectiveness

Page 15: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

15

Effectiveness Assessment

• Are we achieving what we hoped to do?

• Are we matching limited resources to the correct patients?

• These questions can guide future directions in the clinic

• Great topics for in-service seminars; continued enthusiasm

• Peer-review of our work

Prostate with Gold Seeds

• Mean 3D Initial

Translation = 5.6 mm

• Mean 3D Final

Translation = 2.8 mm

• 54% of Fx Adjusted

[mm]

Fre

qu

en

cy

0%

20%

40%

60%

80%

0 5 10 15

3D Initial - All Fractions

3D Final - All Fractions

3D Final - Adjusted Fractions

Herman IJROBP 2003

OBI Impact on PatientsPlanar kV Image Analysis

• 55 patients, 4 groups: head and neck (7), abdomen (12), pelvis (20) and lung (6)

•Extract patient setup information

• Analyze data in terms of:

• Amplitude and frequency of shifts

• random and systematic errors

•Try to identify patient population who benefits most

Page 16: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

16

Available Data from OBI patients

Treatment flow:

• Patient set up with lasers

• Pre-shift kV images acquired

• Match kV images to DRRs

• Shift applied (no threshold)

• Post-shift kV images recorded

Post treatment data analysis

laser alignment

kV alignment

Head and Neck

0%

10%

20%

30%

40%

50%

1 3 5 7 9 11 13 15 17

3D Amplitude (mm)

Fre

qu

en

cy

Laser

OBI

Laser: 5.1 ± 1.2 mm

OBI: 1.3 ± 0.4 mm

Amplitude of 3D Shifts & Offsets

Laser: applied shift

OBI: residual offset between post kV image and DRR

Shifts and Offsets for All SitesHead and Neck

0%

10%

20%

30%

40%

50%

1 3 5 7 9 11 13 15 17

3D Amplitude (mm)

Fre

qu

en

cy

Laser

OBI

Laser: 5.1 ± 1.2 mmOBI: 1.5 ± 0.5 mm

Pelvis

0%

10%

20%

30%

40%

50%

1 3 5 7 9 11 13 15 17

3D Amplitude (mm)

Fre

qu

en

cy

Laser: 6.5 ± 3.5 mmOBI: 1.4 ± 0.3 mm

Laser

OBI

Abdomen

0%

10%

20%

30%

40%

50%

1 3 5 7 9 11 13 15 17

3D Amplitude (mm)

Fre

qu

en

cy

Laser: 7.0 ± 3.3 mmOBI: 1.3 ± 0.4 mm

Laser

OBI

Lung

0%

10%

20%

30%

40%

50%

1 3 5 7 9 11 13 15 17

3D Amplitude (mm)

Fre

qu

en

cy

Laser: 6.2 ± 2.4 mmOBI: 2.1 ± 0.5 mm

Laser

OBI

Laser: applied shift

OBI: residual offset between post kV image and DRR

Page 17: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

17

Systematic Error (Σgroup) Reduction

Factor 6 reduction in Σgroup

0.0

1.0

2.0

3.0

4.0

5.0

6.0

Σg

rou

p(m

m)

Laser

OBI

Head & Neck Abdomen Pelvis Lung

Random Error (σgroup) Reduction

Factor 3 reduction in σgroup

0.0

1.0

2.0

3.0

4.0

5.0

σg

rou

p(m

m)

Laser

OBI

Head & Neck Abdomen Pelvis Lung

Inter-system Consistency Checks/Accuracy Comparisons

• CBCT is our preferred localization technique for SBRT lung pts.

•How much better than OBI localization

• Bony anatomy localization

• Soft tissue visualization

Page 18: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

18

OBI/CBCT Comparison

• Acquire CBCT, localize patient based on visualization of tumor

• Acquire OBI images post-shift

• Compare:

• CBCT soft-tissue localization to OBI bony alignment

• CBCT bony anatomy localization to OBI bony alignment

CBCT-OBI Bony Alignment

•Usually comparable, with a few exceptions

•Occasional ~cm differences between CBCT and OBI

• Intra-treatment patient motion?

• Technological problems?

• User error?

Sub-Optimal OBI Implementation

Page 19: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

19

Sub-Optimal OBI Implementation

Sub-Optimal OBI Implementation

Technology Inter-comparison

• Justified clinical application of higher dose, higher workload technology for a certain application (Lung SBRT)

• Illustrated shortcomings in our process for training, documentation, and continuing education

Page 20: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

20

Summary

• Effective IGRT requires a multi-disciplinary approach

• Substantial potential for patient harm if things are done badly, but incredible potential for great things when well crafted protocols are expertly executed

• Thanks

Which strategy is most likely to lead to

uniform, clinically efficacious image

guidance of head and neck treatments?

19%

21%

20%

21%

20%1. Documentation of physician instructions for

anatomy matching

2. Automated mutual information matching algorithms

3. Extended treatment schedule slots that allow more time for imaging and analysis

4. Manual matching algorithms based on chamfer matching

5. Six degree of freedom robotic couch tops

Answer:

• Documentation of physician instructions for anatomy matching

• Reference: IGRT QA Whitepaper, Jaffrayet al., to be published in PRO

Page 21: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

21

Which patient trait at time of simulation was

found by de Crevoisier et al. to correlate with higher rate of biochemical failure after

external beam therapy for prostate cancer?

21%

19%

18%

21%

21% 1. Body mass index (BMI)

2. Prostate volume

3. Cross-sectional area of rectum

4. Respiratory period

5. Bladder volume

Answer:

• Cross-sectional area of rectum

• Source: de Crevoisier, R., S. L. Tucker, et

al. (2005). "Increased risk of biochemical

and local failure in patients with distended rectum on the planning CT for prostate

cancer radiotherapy." Int J Radiat Oncol

Biol Phys 62(4): 965-73.

Which of the following QA strategies would

most likely detect a problem arising from differing image interpretation by two

commercial elements of an IGRT process?

19%

21%

19%

21%

20% 1. Analysis of DICOM image headers

2. Check-sum analysis before and after image transfer

3. End-to-end test of the IGRT process

4. Careful study of each product’s user manual

5. Pre-treatment chart review of each patient’s imaging parameters

Page 22: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

22

Answer:

• End-to-end test of the IGRT process

• Reference: Yin, F. F., J. W. Wong, et al.

(2009). TG-104: The Role of In-Room kV

X-Ray Imaging for Patient Setup and Target Localization. College Park, MD,

AAPM.

A primary advantage of Ceiling/Floor

mounted planar kV imaging systems is:

19%

22%

21%

21%

18% 1. Tomographic imaging capabilities

2. Rapid acquisition of dual radiographs

3. Large field of view

4. Easy interpretation of oblique patient views

5. Coincident imaging/therapy x-ray sources

Answer:

• Rapid acquisition of dual radiographs

• Reference: Yin, F. F., J. W. Wong, et al.

(2009). TG-104: The Role of In-Room kV

X-Ray Imaging for Patient Setup and Target Localization. College Park, MD,

AAPM.

Page 23: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

23

Which equipment could be used to monitor

intra-fractional patient motion without administering any imaging dose?

20%

19%

19%

20%

22% 1. Cone-beam CT

2. EPID

3. 4DCT on rails

4. BAT Ultrasound

5. Stereoscopic x-ray tubes

Answer:

• EPID

• Reference: Herman, M. G., J. M. Balter, et

al. (2001). "Clinical use of electronic portal

imaging: report of AAPM Radiation Therapy Committee Task Group 58." Med

Phys 28(5): 712-37.

Which treatment scenario best justifies the

increased dose associated with intra-fractional CBCT imaging?

22%

19%

21%

18%

20% 1. Prostate IMRT with gold markers

2. Lung

3. Head and neck

4. SBRT spine

5. Breast

Page 24: Initiation of an IGRT Program - AMOS Onlineamos3.aapm.org/abstracts/pdf/68-19964-237349-85463.pdf · 1 Initiation of an IGRT Program Jon J. Kruse, Ph.D. Dept. of Radiation Oncology

24

Answer:

• SBRT Spine

• Reference: Murphy, M., J. M. Balter, et al.

(2007). "The management of imaging dose

during image-guided radiotherapy: Report of the AAPM Task Group 75." Med Phys

34(10): 4041-4061.