Hangzhou Zetian Technology Co.,Ltd.
Focusing on Environmental & Industrial Analysis
SelectionGuide
Industrial Process Analysis
Gas Emission Monitoring
Water Pollution Monitoring
Environmental Monitoring
Hangzhou Zetian Technology Co., Ltd. , founded in 2008, is located in Hangzhou, Zhejiang Province, China. We are a
professional manufacturer of high-tech environmental monitoring equipment, analytical instruments, industrial process
control and industrial safety products.
We have five major products' series:Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, water quality testing
instruments, air quality monitoring systems, and gas leak alarm. We developed more than 60 product models for these series,
basically covering air and water pollution monitoring, metallurgical industries, chemical and other on-line monitoring needs.
Some of our products include back-scatter laser dust meter, high temperature humidity meter, denitration escape ammonia
analyzer, sulphur analyzer, trace C1 analyzer system, immersive UV broad spectrum water analyzer, ammonia nitrogen 2
analyzer, colorimetric heavy analyzer, anodic stripping voltammetry heavy metal analyser etc.
We’ve combined integrated fields including microelectronics, telecommunication, software, electrical and mechanical
engineering and other area of technology. We are among the few worldwide manufacturers that have proprietary right for gas
analysis, water analysis and dust analysis products at the same time. We're technology innovation oriented driven organization.
We trade with many corporate customers, including domestic and foreign source on-line water/gas monitoring / process
analysis system integrator; agents, operation and maintenance providers; equipment manufacturers, thermal power plants,
sewage treatment plants, chemical plants and the like. We provide our clients with highly cost-effective intellectual monitoring
instrumentation and analysis equipment, analysis module/component, CEMS program sets, complete set of water quality
analysis program and other similar products. We accept OEM, also provide ODM, on behalf of operation and maintenance and
other services.
Hangzhou Zetian Technology is committed to the integrity, strength and quality of our products. We're internationally
recognized. We warmly welcome you to visit us for business negotiation and products' inspection.
INTRODUCTION
CONTENTS
01Industrial Process Analysis & Safety Alarming
Gas EmissionContinuous Monitoring
02
EM-5 Flue Gas Analyzer
EM-5
GA-5000M
EM-5-HW
EM-5-CD
PT-500H
HM-100
HM-200
GSP-100
GSP-200
GSP-300
MS-1000
DMS-200
DMS-300
(Standard Form) 05
Flue Gas Analyzer (Ultra-low Form) 05
Flue Gas Analyzer OEM Module 05
GA-5000W Ultra Low Detection Module Based On The White Pool 06
Continuous Emission Monitoring System 06
Continuous Emission Monitoring System 06
SCEM-5 Continuous Emission Monitoring System(Ultra-low hot wet) 07
EM-5 Continuous Emission Monitoring System(Dilution method) 07
EM-5P Portable Flue Gas Analyzer 08
GCOM-3000 VOCs Volatile Organic Compounds Online Analyzer 08
GCOS-3000 VOCs Volatile Organic Compounds Online Monitoring System 09
GCOM-4000-VOCs Water Volatile Organic Compounds Online Analyzer 09
High-Precision Integration Monitor of Temp., Press. and Flow 10
Hygronom 10
Hygronom 10
HM-300 Hygronom 11
Sampling Probe 11
Sampling Probe 11
Sampling Probe 12
Dust Monitoring Device(Backword scattering) 12
DMS-100 Dust Monitoring Device(Backword scattering) 12
Dust Monitoring Device 13
Dust Monitoring System 13
LGT-100
LGT-106
LGT-150
LGT-180
GA-5000
Laser Gas Analyzer 01
Laser Gas Analyzer 01
Laser Gas Analyzer 01
Laser Gas Analyzer 02
LGT-200 Laser Gas Analyzer 02
GA-5000DN DeNOx Ammonia Slip Online Monitoring System 02
GA-5000nao DeNOx Ammonia Slip Integration Online Monitoring System 03
Waste Incineration HCl/HF Analyzer 03
Pulverized Coal Bunker CO/O Analysis System 032
Trace Cl Analysis System 042
Sulfur Ratio Instrument 04
03Water PollutionContinuous Monitoring
04Environmental Monitoring
AQMS-100
EQMS-3000
VOCs Online Monitoring System 22
AEM-1000 Atmospheric Extinction Monitoring System 22
Environmental Quality Monitoring Sytem 22
DPM-6000 PM2.5/PM10 Particulate Monitoring System 23
PMMS-5000 Atmospheric Heavy Metals Analyzer 23
AEM-2000 NO Analyzer 232
AM-5100 SO Analyzer 242
AM-5200 NOx Analyzer 24
AM-5300 CO Analyzer 25
AM-5400 Ozone Analyzer 25
AM-5800 Dynamic Dilution Calibration 25
AM-5900 Zero Gas Generation 26
CONTENTS
CODet-5000 CODcr 14
WDet-5000 Ammonia-Nitrogen Water Quality Online Automatic Analyzer 14
WDet-5000 Total Phosphorus Water Quality Online Automatic Analyzer 15
Total Nitrogen Water Quality Online Automatic Analyzer 15
Permanganate Index Water Quality Analyzer 16
Heavy Metal Water Quality Online Analyzer 16
Anodic Stripping Heavy Metal Water Quality On-line Analyzer 17
WDet-5000CN Cyanide Water Quality Online Analyzer 18
PDV-5000X Portable Anodic Stripping Heavy Metal Analyzer 8
Immersion Water Quality Analyzer 18
COD/Ammonia Nitrogen Integration Water Quality Online Analyzer 19
TP/TN Integration Water Quality Online Analyze 19
TP/TN/COD Integration Water Quality Online Analyzer 20
Cr/Total Cr Integration Heavy Metal Water Quality On-line Analyzer 21
Water Quality Online Automatic Analyzer
WDet-5000TN
WDet-5000Mn
MDet-5000X
MDet-6000X
1
WDet-5000UVI
WDet-5000
WDet-5000
WDet-5000TPN
MDet-5000
Name LGT-100 Laser Gas Analyzer(In situ)
Classification Industrial Process Analysis and Process Safety Alarming
Description
LGT-100 is a flameproof in-situ probe-type tunable laser gas analyzer for industrial online analysis and environmental
on-line monitoring, which can online analyze O , CO, NH , CO , CH , H O, HCl, HF and other gases in various complex 2 3 2 4 2
conditions (NOTE: A single analyzer can only analyze 1~2 components). Measuring concentration range from major to
trace.
Specification
« Linearity Error::≤±1%F.S.
«Span Drift: ≤±1% F.S./half year
«Type of Protection:ExdIICT6 Gb
« Enclosure Rating:IP66
« Response Time:≤1s(T )90
«Analog Output: 2× 4-20mA output
«Analog Input: 2× 4-20mA input
« RS485/RS232/GPRS
«Working Temp.:-20℃~+60℃
«Purge Gas: 0.3MPa ~ 0.8MPa N , clean air2
Digital Communications:
Feature
v
vModular design, laser module field replaceable, easy maintenance
v
v
In-situ instal. and real-time measurement avoid pre-treatment sample adsorption, congestion and component damage
Single spectrum measuring is interfered from background gasestechnology
The optical path achieves uncoupling directional adjustment, ambient light path adjusts simply
Application
Apply to converter gas recovery gas analysis, CDQ circulating gas analysis; oxygen measuring electric fishing coke oven
gas after analysis; pulverized coal injection gas analysis; ammonia escaping gas analysis in the cement industry; trace CO
detection and analysis ; HCl and HF trace analysis in electricity, cement, environmental protection environmental
protection and chemical industry
Name LGT-106 Laser gas analyzer(Bypass)
Classification Industrial Process Analysis and Process Safety Alarming
Description
LGT-106 is a flameproof bypass type tunable laser gas analyzer for industrial on-line analysis and environmental on-line
monitoring, especially suitable for high temperature, high humidity, high dust, high pressure, harsh working conditions
and small pipes where in-situ analyzer is not applicable. It can online analyze O , CO, NH , CO , CH , H O, HCl, HF
and other gases of various complex conditions (NOTE: A single analyzer only can analyze 1~2 components). Measuring
concentration range from major to trace.
2 3 2 4 2
Specification
« Linearity Error::≤±1%F.S.
«Span Drift: ≤±1% F.S./ half year
«Type of Protection:ExdIICT6 Gb
« Enclosure Rating:IP66
«Response Time:≤30s(as per field condition )
«Analog Output: 2× 4-20mA output
«Analog Input: 2× 4-20mA input
« RS485/RS232/GPRS
«Working Temp.:-20℃~+60℃
«Purge Gas: 0.3MPa ~ 0.8MPa N , clean air2
Digital Communications:
Feature
v
v advantages
v easily
v
Suitable for high temperature, high humidity, high dust, high pressure, harsh working conditions and small pipes
Automatic calibration and backblow
Integrated proof design has the of high reliability and stability
Innovative Hall button design, good sensitivity, operate
ApplicationApply to trace H S and gas industry; in petrochemicals, coal chemicals, 2
and environmental protection industries ; detection and analysis in ; mill inlet gas detection and
analysis.
H O detection and analysis in trace H S analysis2 2
trace H O chlorine gas2
Name LGT-150 Laser gas analyzer(Multichannel)
Classification Industrial Process Analysis and Process Safety Alarming
Description
LGT-150 is a explosion-proof multichannel type tunable laser gas analyzer for industrial online analysis and
environmental on-line monitoring. The instrument adopts distributed measurement, which analyses the gas
concentration of multi spot in real time. It can online analyze O , CO, NH , CO , CH , H O, HCl, HF and other 2 3 2 4 2
gases of various complex conditions (NOTE: A single analyzer only can analyze 1~2 components). Measuring
concentration range from major to trace.
Specification
« Linearity Error::≤±1%F.S.
«Span Drift: ≤±1% F.S./half year
«Type of Protection:ExdIICT6 Gb
« Enclosure Rating:IP66
« The Central Unit Structure: 19 inches
«Analog Output: 2× 4-20mA output
«Analog Input: 2× 4-20mA input
« RS485/RS232/GPRS
«Working Temp.:-20℃~+60℃
«Purge Gas: 0.3MPa ~ 0.8MPa N , clean air2
Digital Communications:
Feature
v
v
v
v
Centralized controlling supports up to eight measurement channels, intelligent management
Cost-effective,
The maximum transmission distance of probe to the central unit is up to 1000 meters
Multi-channel distributed measurement, any failure of any probe does not affect the normal operation of the central
unit or other probes
reducing investment of customers
ApplicationApply to gas analysis of metallurgical furnaces, petrochemical chemical refining, urea chlor-alkali manufacturing
process, industrial flue gas denitration, waste incineration, and process control of cement production combustion
thermal combustion.
01 en.zetian-tech.com
Industrial Process Analysis & Safety Alarming
Name LGT-180 Laser gas analyzer(Panel mounted)
Classification Industrial Process Analysis and Process Safety Alarming
Description
LGT-180 is a panel mounted type tunable laser gas analyzer for industrial online analysis and environmental on-
line monitoring. The instrument adopts white cell to achieve folded optical path up to 25 meters. With this
technique low detection limit can be reached. It can online analyze O , CO, NH , CO , CH , H O, HCl, HF and 2 3 2 4 2
other gases of various complex conditions (NOTE: A single analyzer only can analyze 1~2 components).
Measuring concentration range from major to trace.
Specification
« Linearity Error:≤±1%F.S.
«Span Drift: ≤±1% F.S./half year
«Calibration Cycle:≤2 times/ year
«Response Time: ≤30s(as per field condition)
«The Central Unit Structure: 19 inches
«Analog Output: 2× 4-20mA output
«Analog Input: 2× 4-20mA input
« : RS485/RS232/GPRS
«Working Temp.: -20℃~+60℃
«Purge Gas: 0.3MPa ~ 0.8MPa N , clean air2
Digital Communications
Feature
v
v
v
19 inches 3U panel mounted chassis, exquisite construction
TDLAS eliminates cross-interference of background gases
v Multiple return optical path up to 25 meters, obviously lower detection limit
No optical moving parts, high reliability, not affected by field vibration
ApplicationApply to gas analysis of metallurgical furnaces, petrochemical chemical refining, urea chlor-alkali
manufacturing process, industrial flue gas denitration, waste incineration, and process control of cement
production combustion thermal combustion.
Name LGT-200 Laser gas analyzer(Flameproof)
Classification Industrial Process Analysis and Process Safety Alarming
Description
LGT-200 laser gas analyzer uses TDLAS technology and long-path reflection technology, which greatly lower
the detection limit. It can analyze O , CO, NH , CO , CH , H O, HCl, HF, etc., providing a new solution of 2 3 2 4 2
online measurement of trace gases for natural gas, petrochemicals, environmental protection and steel and other
industrial applications.
Specification
« Linearity Error:≤±1%F.S.
«Span Drift: ≤±1% F.S./half year
«Type of Protection: ExdIIB+H T5 GB2
« Enclosure Rating:IP65
«Response Time:≤30s(as per field condition)
«Analog Output: 2×4-20mA output
«Analog Input: 2×4-20mA input
« RS485/RS232/GPRS
«Relay Output: 3(24V, 1A)
«Working Temp.: -20℃~+60℃
Digital Communications:
Feature
v
v
v
v
Combine TDLAS and long-path technology to improve the detection limit
Integration proof method, applicable to explosive situations
OLED screen featuring light weight, wide viewing angle, fast response adapt to industrial environments
Backplane is from flameproof enclosure,easy to maintainseparated
Application
Apply to trace HCl and HF analysis of chemical industry, environmental protection and other industries; trace H S analysis of natural gas, petrochemical, environmental protection, coal and chemical 2
industries; CO analysis of medical, coal chemical industry, environmental protection and other 2
industries; trace CO analysis of electricity, cement, steel, environmental protection and other industries.
02
Industrial Process Analysis & Safety Alarming
en.zetian-tech.com
Name GA-5000DN Ammonia Slip Online Monitoring SystemDeNOx
Classification Industrial Process Analysis and Process Safety Alarming
Description
GA-5000DN is based on a tunable semiconductor laser absorption spectroscopy (TDLAS) technology principle,
including three parts: pretreatment, gas analysis module and data processing and display. After dusting by
sampling probe, sampling by heating pipe, the measured gas is analyzed by the hot gas analysis module
(TDLAS technique).It is an effective solution to the technical problem that ammonium salt crystallization plugs
flow at low temperature ,and that absorption of NH by condensation water leads to low measurement precision, 3
and that in situ system high dust attenuation light path leads to unmeasurable.
Specification
«Technology: tunable semiconductor laser
absorption spectroscopy (TDLAS)
«Range:0~10ppm~1000ppm
«Linearity Error:≤±1%F.S.
«Zero Drift:≤±1%F.S./half year
«Span Drift:≤±1%F.S./half year
«Response Time:<90s
«Analog Output:5× 4-20mA
«Analog Input: 3× 4-20mA
«Digital Output:RS485/RS232/GPRS
«Detection Limit:0.1ppm 10m optical path
«Purge Gas: 0.4MPa ~ 0.8MPa N , clean air2
(T )90
( )
Feature
v
v
v
v
Single line spectrum technology avoid interference of background gas absorption, low detection limit, small
scale drift
More than 220 ℃ heat tracing avoid ammonium salt crystallization and moisture dissolve and absorption
A high degree of automation, small amount of maintenance
Compact structure, easy to install
Name GA-5000nao Integration Online Monitoring SystemDeNOx Ammonia Slip
Classification Industrial Process Analysis and Process Safety Alarming
Description
GA-5000nao (NH 、 NO、 O ) is based on a tunable semiconductor laser absorption spectroscopy 3 2
(TDLAS) and ultraviolet difference absorption spectroscopy (DOAS) technology principle, including three parts: pretreatment, gas analysis module and data processing and display. After dusting by sampling probe, sampling by heating pipe, the measured gas is analyzed by the hot gas analysis module (TDLAS +DOAS technique). It is an effective solution to the technical problem that ammonium salt crystallization plugs flow at low temperature ,and that absorption of NH by condensation water leads to 3
low measurement precision, and that in situ system high dust attenuation light path leads to unmeasurable.
Specification
«Technology: tunable semiconductor laser
absorption spectroscopy (TDLAS)+
ultraviolet difference absorption spectroscopy
(DOAS) technology +zirconia
«Range:
NH 0~10ppm~1000ppm3
NO 0~50ppm~5000ppm
O 0~25%2
«Linearity Error:≤±1%F.S.
«Repeatability:≤1%
«Zero Drift:≤±1%F.S./half year
«Span Drift:≤±1%F.S./half year
«Response Time:<90s
«Analog Output:5× 4-20mA
«Analog Input: 3× 4-20mA
«Digital Output:RS485/RS232/GPRS
«Detection Limit:0.1ppm 10m optical path
«Purge Gas: 0.4MPa ~ 0.8MPa N , clean air2
(T )90
( )
Specification
vSingle line spectrum technology avoid interference of background gas absorption, low detection limit, small
scale drift
vMore than 220 ℃ heat tracing avoid ammonium salt crystallization and moisture dissolve and absorption
Compact structure, easy to install, high degree of automation, small amount of maintenance
Multi-parameter integrated on the same system, measured at the same time, low cost
v
v
ApplicationApply to the ammonia escape emission monitoring and process control of SCR or SNCR deNOx device such as
coal-fired power plant, aluminium plant, steel mills, smelting, glass factory, garbage power plant, cement plant,
chemical plant, etc.
ApplicationApply to the ammonia slip emission monitoring and process control of SCR or SNCR deNOx device such as
coal-fired power plant, aluminium plant, steel mills, smelting, glass factory, garbage power plant, cement plant,
chemical plant, etc.
Name Waste Incineration HCL/HF Analyzer
Classification Industrial Process Analysis and Process Safety Alarming
Description
Waste incineration plants require automatic continuous monitoring main component content in flue gas, which include CO, HF, HCl, SO , NOx and soot, while HCl and HF are the difficulties in 2
detection.Under the condition of demand, the company developped a waste incineration HCl/HF analyzer. The principle of the system is based on the TDLAS technology, using the white pool retracing optical path structure design, measuring HCl and HF by high temperature hot wet extraction method.
Specification
«
« : . ppm
«
« : (T )90
Range ~ customizable
Detection Limit 0 5
Zero Drift:≤±1%F.S./7 day
«Span Drift:≤±1%F.S./7 day
Response Time ≤10s
:0 50ppm( ) «Enclosure Rating IP65
«Analog Output: 4×
«Digital Output RS485
«Heating Temperature >150℃
«Working Temperature:-10℃~+55℃
:
4-20mA
:
:
03
Industrial Process Analysis & Safety Alarming
en.zetian-tech.com
Feature
v
v
v
v
Above 150 ℃ high temp. heating extraction, prevent dust and water vapor interference, avoid HCl/HF
dissolving in water to form acid
In-situ installation, reducing pipeline gas adsorption of HCl and HF, improve the measurement precision
Adopt the most advanced online HCl and HF analysis technology “TDLAS + white pool”
No moving parts, powerful functions, support automatic calibration and remote operation maintenance,
remote software upgrade, etc.
ApplicationApply to many environmental and industrial process gas emissions monitoring, mainly used for the incinerator flue gas analysis
Name Pulverized Coal Bunker CO/O Analysis System2
Classification Industrial Process Analysis and Process Safety Alarming
Description
Pulverized coal bunker CO/O analyzer is an electrical instrumentation equipment designed for blast 2
furnace coal injection system online continuous detection of gas composition. Gas in the mill is sampled by instrument sampling probe installed on the mill (or mill outlet piping).Under the action of jet pump, sampling gas through probe filtering, heating and cooling (for high temperature occasion), then enter bypass tube (laser analysis module) for analysis measurement.
Specification
« :
« :
« :
«
Linearity Error ≤±1%F.S.
«Span Drift: ≤±1% F.S./half year
Type of Protection ExdIICT6 Gb
Enclosure Rating IP66
Response Time: ≤30s (as per field condition)
«Analog Output:2×4-20mA
«Analog Input: 2×4-20mA
RS485/RS232/GPRS
«Working Temp.:-20℃~+60℃
«Purge Gas: 0.3MPa ~ 0.8MPa N , clean air2
«Digital Communications:
Name Trace Cl Analysis System2
Classification Industrial Process Analysis and Process Safety Alarming
Description
It is a device for real-time continuous measurement of free chlorine in hydrogen chloride for flammable, corrosive, massive toxic and hazardous substances, complex production process, continuous production conditions of the chlor-alkali industry PVC production. The device system is based on ultraviolet spectrometry technology, using positive pressure explosion-proof design, with high accuracy, high reliability, low operating costs, fast response time, wide range.
Specification
« Accuracy:≤±2%F.S.
« Sensitivity: ≤±1% F.S.
«Span Drift: ≤±1% F.S./half year
«Warm-up Time: ≤15min
« Response Time:≤20s(T )90
«Explosion-proof Way: Positive Purge
«Type of Protection:ExdIICT6 Gb
« Enclosure Protection:IP65
«Analog Output: 4-20mA output, max load 500Ω
«Relay Output: 2 relay, 24VDC, 1A
« RS485
«Power: 220VAC, 50Hz
«Power Rate: ≤200W
«Purge Gas: 0.3MPa ~ 0.8MPa N , clean air2
Digital Communications:
Feature
vUV differential spectrum effectively avoids the interference and improves the measurement accuracy
vMeasuring cell with thermal insulation prevents the formation of acid mist in samples
vCorrosivity of the sample considered, emergency protection designed
vAutomatic zero set, regular correction
ApplicationApply to flammable, corrosive, massive toxic and hazardous substances, complex production process,
continuous production conditions of the chlor-alkali industry PVC production
Name GA-5000 TGA Sulfur Ratio Instrument
Classification Industrial Process Analysis and Process Safety Alarming
Description
With UV differential optical absorption spectroscopy (DOAS) analysis technology, it is mainly used in
process gas control of the Claus industrial sulfur recovery process. The ratio meter measures the
concentration of H S and SO real-time, and calculates the molar ratio, then feeds back the signal to the 2 2
control device that controls air intake to achieve feedback. It has significant advantages including low
detection limit, accurate measurement results, easy calibration and alignment, simple and compact structure,
no moving parts.
Specification
«Range:0~1%~5%(configurable)
«H S Range:0~1%~5%(configurable)2
«Indication Error:less than ±2%
«Repeatability:1%F.S.
«Zero Drift:less than ±2%F.S./7d
«Span drift:less than ±2%F.S./7d
«4-20mA Inputs: 4, flexible configuration
«4-20mA Output: 6, flexible configuration
SO2 «Digital Communications: 1×RS232, 1×RS485
«Power:220VAC, 4kW
«Light Source:high performance xenon strobe
«Working Temp.:-10℃~+50℃
«Heating:electric heating and steam heating
«Warm-up Time:<40min
«Explosion-proof Mark:ExpIICT6 IP65
«Sample Gas Flow Rate:(1.5~2)L/min
04
Industrial Process Analysis & Safety Alarming
Feature
vUsing the TDLAS technology to avoid the influence of gaseous water and interferentialgas on CO
measurement
vHigh stability, long calibration cycle, low maintenance quantity
vSupportting automatic calibration, automatic blowback
vNo mechanical moving parts, vibration resistance interference
ApplicationApply to the coal pulverizing system of hot blast stove exports, ball mill into exports, cyclone export machine,
flour bag exports, powder warehouse entry, process gas pipeline, etc.
en.zetian-tech.com
Feature
v
v
v
v
Installed directly on the flue, in-situ measurement, fast response
Specially designed mist catcher allows efficient removing of sulfur to prevent the blockage of probe.
Full spectrum measurement avoids SV, COS interfering H S, SO and achieves high measurement accuracy2 2
Multi-channel spectral analysis technique allows simultaneously measurement of multiple components
ApplicationApply to sulfur recovery ratio control of oil refineries, natural gas purification plant, coking plants, chemical
plants, power plants, coal gasification plant, process control of ammonia methanol, feedstock gas productionand
refinery gas processing.
Gas Emission Continuous Monitoring
Name EM-5 Flue Gas Analyzer(Standard Form)
Classification Gas Emission Continuous Monitoring
Description
EM-5 flue gas analyzer is a gas analysis product for domestic and overseas environmental
on-line monitoring online analysis. The analyzer is based on DOAS and chemometric algorithms
PLS), able to measure SO , NO, NO , O , NH , CO, CO , Cl , O , H S, HCl, CH I, etc.. With high accuracy and 2 2 2 3 2 2 3 2 3
reliability, low operating costs, fast response time, wide
self-developed and
industrial
measurement range and application fields, it has
achieved even surpassed similar products home and abroad.
Specification
«Measuring Technique: DOAS(SO 、NOx), 2
Electrochemistry(O )2
«Measuring Range: 0~300~3000ppm(SO 、2 NOx), 0-25%(O )2
«Linearity Error:less than ±1%F.S.
«Repeatability:less than ±0.5%F.S.
«Zero Drift:less than ±2%F.S./7d
«Span Drift:less than ±2%F.S./7d
«Response Time:<10s(T )90
«Warm-up Time:None
«Relay Output:14
«Binary Input:6
«Analog Output:5×4 -20mA
«Analog Input:3×4 -20mA
«Digital Comm. :RS485/RS232/GPRS
«Enclosure Rating:IP42
«Working Temp.:-10℃~+40℃
«Working Humidity:0~95%RH
Feature
v
v
v
v
Low detection limit and temperature-drift
Getting NOx by directly measuring NO and NO without NO →NO converter2 2
No interference of particulate matter, moisture and other factors
No optical moving parts, high reliability, no interference to the measurement by field
ApplicationApply to exhaust emission monitoring and process control such as coal-fired power plants, garbage power plant,
cement, glass, lime factory, ceramics factory, sinter, coke oven, desulfurization, denitration technology.
Name EM-5 Flue Gas Analyzer(Ultra-low Form)
Classification Gas Emission Continuous Monitoring
Description
EM-5 flue gas analyzer is a self-developed gas analysis product of multiple return light path. The analyzer is
based on DOAS and chemometric algorithms (PLS), able to measure SO , NO, NO , O , NH , CO, Co , Cl , O , 2 2 2 3 2 2 3
H S, HCl, CH I, etc. With high accuracy and reliability, low operating costs, fast response time, wide 2 3
measurement range and application fields, it has achieved even surpassed similar products home and abroad.
Specification
«Measuring Technique: DOAS(SO 、NOx), 2
Electrochemistry(O )2
«Measuring Range: 0~20~100ppm(SO 、NOx), 2
0~25%(O )2
«Linearity Error:less than ±1%F.S.
«Repeatability:≤0.5%
«Zero Drift:less than ±2%F.S./7d
«Measuring Range Drift: less than ±2%F.S./7d
«Response Time:<10s(T )90
«Warm-up Time:None
«Relay Output:14 channels
«Binary Input:6 channels
«Analog Output:5×4 -20mA
«Analog Input:3×4 -20mA
«Digital Comm. :RS485/RS232/GPRS
«Enclosure Rating:IP4
«Working Temp.:-10℃~+40℃
«Working Humidity:0~95%RH
Feature
vLow detection limit and temperature-drift
vGetting NOx by directly measuring NO and NO without NO →NO converter2 2
vNo interference of particulate matter, moisture and other factors
vNo optical moving parts, high reliability, no
v
interference to the measurement by field
Vibration Using return light path and high quality spectrograph, the minimum measuring range is 0-20ppm,
lowest detection limit is 200ppb
ApplicationApply to exhaust emission monitoring and process control such as coal-fired power plants, garbage power plant,
cement, glass, lime factory, ceramics factory, sinter, coke oven, desulfurization, denitration technology and etc.
Name GA-5000M OEM ModuleFlue Gas Analyzer
Classification Gas Emission Continuous Monitoring
Description
It is used for measuring harmful gas composition from pollution discharge pipes, mainly used for departments
of environmental monitoring and thermal parameter measurement. It's used to monitor harmful gas
concentration of SO , NO, NO , and etc. Compared with the instrument using electrochemical sensor 2 2
measurements, it has higher accuracy, higher reliability, faster response time, longer service life, and etc.
Module using imported long optical path multicomponent detection device, innovation anti-jamming algorithm
and high technology of sensors and new materials.
05 en.zetian-tech.com
Specification «Linearity Error:less than ±1%F.S.
«Repeatability:≤0.5%
«Stability:≤2%
«Response Time:<25s(T )90
«Zero Drift:less than ±2%F.S./7d
«Span Drift:less than ±2%F.S./7d
Feature
v
v
v
Long light path gas absorption chamber, High measurement accuracy, measure a variety of gases at the same
time
No moving parts, high reliability
Small volume, light weight, convenient to carry and onboard using
ApplicationApply to exhaust emission monitoring and process control such as coal-fired power plants, garbage power plant,
cement, glass, lime factory, ceramics factory, sinter, coke oven, desulfurization, denitration technology and etc.
Name EM-5-HW Continuous Emission Monitoring System
Classification Gas Emission Continuous Monitoring
Description
CEMS has four basic parts: the dust monitoring subsystem, gaseous pollutants monitoring subsystem, flue gas
parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor
SO , NOx, O , dust, temperature, pressure, flow rate and other parameters such as HCl, HF, CO, CO for a 2 2 2
particular occasion. After dedusting by sampling probe, sampling by heating pipe, the measured gas is analyzed
by the hot gas analysis module (TDLAS and DOAS technique). It is an effective solution to the technical
problem that absorption of SO by condensation water leads to low measuring data. Especially in low 2
concentration measurement occasions, it has incomparable advantages.
Specification
«SO 0~300ppm~3000ppm2
«NOx 0~300ppm~3000ppm
«O 0 25%2
«Humidity 0 40%3 3
«Dust (0-200mg/m )~(0-10g/m )
«Flow Rate 0 40m/s(customizable)
«Temperature 0 300℃(customizable)
«Pressure -10kPa~+10kPa(customizable)
:
:
: ~
: ~
:
: ~
: ~
:
«Size: 800mm×600mm×1800mm
«Heating Pipe, Probe Temp.: 120℃~180℃
«Enclosure Rating: cabinet IP42, others IP65
«Power Supply:220VAC, 5000W
«Working Temp.:-20℃~+50℃
«Working Humity:0~95%RH(no condensation)
«Compressed Air Requirement: 0.4-0.8 MPa,3 0.25m /min, clean, without oil or water
( )
Feature
v
v
v
v
vThe whole calibration can be realized
All the indexes are measured in the condition of high temperature, avoiding low measuring data which
resulted from the absorption of SO by condensation water2
Simple system structure, no moving parts such as diaphragm pumps and peristaltic pump, high reliability
Self-developed core module and algorithm
Compact structure, convenient to transport and installation
ApplicationApply to exhaust emission monitoring and process control such as coal-fired power plants, garbage power plant,
cement, glass, lime factory, ceramics factory, sinter, coke oven, desulfurization, denitration technology and etc.
Name GA-5000W UV Ultra Low Detection Module Based On The White Pool
Classification Gas Emission Continuous Monitoring
Description
It is used for gas composition test of low and ultra-low measuring range.The core component is white pool gas
compartment. It can achieve multiple return and adjust the reflection times to change return optical path
according to the needs. The effective optical path is long. Compared with the normal gas compartment, the
structure is more compact. The effective optical path increases more than 10 times. It has higher accuracy,
higher reliability, faster response time, longer service life, and etc.
Specification«Linearity Error:less than ±2%F.S.
«Repeatability:≤0.5%
«Stability:≤2%
«Response Time:<30s(T )90
«Zero Drift:less than ±2%F.S./7d
«Span Drift:less than ±2%F.S./7d
Feature
v
v
v
v
Using white pool multiple return absorption gas compartment, compact structure, long effective optical path
High accuracy, measuring various gases at the same time
Gas chamber is separated from the light source and receiving end, convenient for maintenance
No moving parts, high reliability
ApplicationApply to exhaust emission monitoring and process control such as coal-fired power plants, garbage power plant, cement, glass, lime factory, ceramics factory, sinter, coke oven, desulfurization, denitration technology and etc.
Name EM-5-CD Continuous Emission Monitoring System
Classification Gas Emission Continuous Monitoring
Description
CEMS has four basic parts: the dust monitoring subsystem, gaseous pollutants monitoring subsystem, flue gas
parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor
SO , NOx, O , dust, temperature, pressure, flow rate and other parameters such as HCl, HF, CO, CO for specific 2 2 2
occasions. After dedusting by sampling probe, sampling by heating pipe, dehydration and cooling by two-step
condensing, the measured gas is analyzed by the heated gas analysis module (TDLAS and DOAS technique).It
Gas Emission Continuous Monitoring
06 en.zetian-tech.com
07
Descriptionis an effective solution to solve the technical problem that great humidity variation of the waste incineration
andother occasions lead to measuring data fluctuation.
Specification
«Size:800mm×600mm×1800mm
«Weight:approx. 250kg
«Heating Pipe, Probe Temp.: 120℃~180℃
«Enclosure Protection:cabinet IP42, others IP65
«Power Supply:220VAC, 4000W
«Working Temp.:-10℃~+40℃
«Working Humity:0~95%RH(non-condensing)
Feature
vFast dehydration and cooling by two-step condensing, reducing contact time of air and water, lower SO loss2
vAnalyzer uses micro-heating technology, reducing maintenance cycle of lens.
vFast sampling by loop sampling pumps, shorten response time
vDehydration and dedust by multi-stage filtration, high reliability
vThe whole calibration can be realized
ApplicationApplication for exhaust emission monitoring and process control such as coal-fired power plants, garbage power
plant, cement, glass, lime factory, ceramics factory, sinter, coke oven, desulfurization, denitration technology
Gas Emission Continuous Monitoring
en.zetian-tech.com
«Range:
SO 、NOx 0~300~3000ppm2
O 0~25%2
Humidity 0~40%3 3Dust (0-200mg/m )~(0-10g/m )
Flow rate 0~40m/s
Temp. 0~300℃
Pressure -10kPa~+10kPa
(customizable)
(customizable)
(customizable)
Name SCEM-5 Continuous Emission Monitoring System(Ultra-low hot wet)
Classification Gas Emission Continuous Monitoring
Description
SCEM-5 has four basic parts: the dust monitoring subsystem, gaseous pollutants monitoring subsystem, flue gas
parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor
SO , NOx, O , dust, temperature, pressure, flow rate and other parameters such as HCl, HF, CO, CO for a 2 2 2
particular occasion. 3The measuring lower limit as low as 1mg/m , full qualified the measurement technology
index of ultra-low emission monitoring occasions, the newest laser forward dust monitoring device is suitable
for the occasion such high wet flue gas, light-leaking chimney, ultra-low dust emission and so on.
Specification
«SO 0~10ppm~100ppm2
«NOx 0~10ppm~100ppm
«O 0 25%2
«Humidity 0 40%3 3
«Dust (0-10mg/m )~(0-50g/m )
«Flow Rate 0 40m/s(customizable)
«Temperature 0 300℃(customizable)
«Pressure -10kPa~+10kPa(customizable)
:
:
: ~
: ~
:
: ~
: ~
:
«Size: 800mm×600mm×1800mm
«Heating Pipe, Probe Temp.: 120℃~180℃
«Enclosure Rating: cabinet IP42, others IP65
«Power Supply:220VAC, 5000W
«Working Temp.:-20℃~+50℃
«Working Humity:0~95%RH(no condensation)
«Compressed Air Requirement: 0.4-0.8 MPa,3 0.25m /min, clean, without oil or water
( )
Feature
v
v
v
v
v
3The measuring lower limit as low as 1mg/m , full qualified the measurement technology index of ultra-low
emission monitoring occasions
Simple system structure, no moving parts such as diaphragm pumps and peristaltic pump, high reliability
Self-developed core module and algorithm
Compact structure, convenient to transport and installation
The whole calibration can be realized
ApplicationApply to exhaust emission monitoring and process control such as coal-fired power plants, garbage power plant,
cement, glass, lime factory, ceramics factory, sinter, coke oven, desulfurization, denitration technology and etc.
Name EM-5 Continuous Emission Monitoring System(Dilution method)
Classification Gas Emission Continuous Monitoring
Description
EM-5 has four basic parts: the dust monitoring subsystem, gaseous pollutants monitoring subsystem, flue gas
parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor
SO , NOx, O , dust, temperature, pressure and flow rate. Measured gas passes filter in 2 2
sampling probe for dust removal; is diluted by probe as fixed ratio and then enters the analyzer via sampling
pipeline. By adopting ultraviolet fluorescence method (SO ) and chemiluminescent method (NOx), this analyzer 2
can precisely measure gaseous pollutants at ppb level. The diluted gas for flue sample gas should be high
dehumidification and dedusting. After flue sample gas being diluted as fixed ratio, the dew point of sample gas
is around -30℃. Thus, no heat tracing is needed for whole sampling pipeline. It effectively solves the technical
problem that the measurement result of SO is on the low side for condensation method. Also, it avoids the high 2
operation cost and hidden danger of the heat tracing of hot wet method.
parameters such as
Specification
«SO 0~2000ppm(customizable)2
«NOx 0~2000ppm(customizable)
«O 0 25%2
«Humidity 0 40%
:
:
: ~
: ~
«Size: 800mm×800mm×2000mm
«Heating Pipe, Probe Temp.: 120℃~180℃
«Enclosure Rating: cabinet IP42, others IP65
«Power Supply:220VAC, 3000W
08
www.zetian-tech.com
Gas Emission Continuous Monitoring
en.zetian-tech.com
Specification
3 3«Dust (0-200mg/m )~(0-10g/m )
«Flow Rate 0 40m/s(customizable)
«Temperature 0 300℃(customizable)
«Pressure -10kPa~+10kPa(customizable)
:
: ~
: ~
:
«Working Temp.:-10℃~+45℃
«Working Humity: (5~95)%RH(no condensation)
«Compressed Air Requirement: 0.4~0.8 MPa,
clean, without oil
( )
Feature
vThe whole calibration and the end calibration can be realized
vNo heat tracing for whole process or humidity removal by condensation method is needed for flue gas.
vTelfon is used for heat tracing pipe. No heat tracing is needed for whole process that saves cost and avoids
hidden danger.
vDilution monitoring system is not affected by exceeding distance. Regular heat tracing is not suitable for the
occasion that the distance between application point and analysis cabin is beyond 70 meters.
vultraviolet fluorescence method and chemiluminescent method have obvious advantage for measurement of
the gaseous pollutants at ultra low level.
ApplicationApply to exhaust emission monitoring and process control such as coal-fired power plants, garbage power plant,
cement, glass, lime factory, ceramics factory, sinter, coke oven, desulfurization, denitration technology and etc.
Name EM-5P ortable Flue Gas AnalyzerP
Classification Gas Emission Continuous Monitoring
Description
EM-5P with UV differential optical absorption spectroscopy(DOAS) analysis technology to monitor gas 3concentration in gas flue such as SO , NOx, O and so on, the lower limit of detection is as low as 0.1mg/m , it 2 2
can configure to measure multiple gas components according to the working conditions, and also can
simultaneously measure flue gas parameters such as temperature, pressure, flow rate, humidity etc.
Specification
«SO 0~20ppm~2000ppm2
«NO 0~2000ppm2
«O 0 25%2
«Humidity 0 40%
«Flow Rate 0 40m/s
«Temperature 0 300℃
«Pressure -30kPa~+30kPa
«
«
、NO:
:
: ~
: ~
: ~
: ~
:
Size: 518mm×182mm×298.2mm
Digital Output: support printer, phone APP, serial port,
remote TCP/IP
«Power Supply:AC 220V±22V, 600W
«Permissible Error
SO 、NO、NO 、O : less than ±2%F.S.2 2 2
: less than ±10%
: less than ±10%
Temperature: less than ±0.3℃
: less than ±0.5%F.S.
«Repeatability: ≤1%
«Zero Drift: less than ±2%F.S./d
«Working Temp.:-20℃~+40℃
«Working Humidity: 1×RS232, 1×USB
Humidity
Flow Rate
Pressure
Feature
v
v detection is
vGetting NOx by directly measuring NO and NO through DOAS technology which without NO → NO 2 2
converter
vSelf-developed core detecting technology and algorithm which have strong market competitiveness
The first at home and abroad who use DOAS technology to measure ultra-low concentration of SO and NOx, 2
which is not affected by the interference of background elements such as dust、H O、CO、CO 、HCl2 2
The measuring pool is using white pool, optical path as long as 10m and lower limit of as low as 30.1mg/m , which are satisfy indicators of ultra low emission concentration
Application
Apply to multi-level environmental monitoring station, the third party inspection agencies, online analysis
instrument production/sales/operations business who do the acceptance of environmental protection, emergency
detection, instrument calibration, polluters audits to the industrial flue gas emissions occasions of coal-fired
power plants, gas power plants, iron and steel plants, and laboratory gas test, etc.
Name GCOM-3000 VOCs Volatile Organic Compounds Online Analyzer
Classification Gas pollution source monitoring
Description
GCOM-3000 is a VOCs monitoring product which use international mainstream chromatographic methods. It
can monitor Organic pollutant gases such as methane, the total hydrocarbon, non methane total hydrocarbon,
low-carbon aldehyde ketone, benzene series(benzene, toluene, xylene, ethyl benzene, isopropyl benzene) and
part of halogenated hydrocarbons by using FID detector and high performance chromatographic separation
column. The pneumatic heating box is designed in the analyzer internal which can solve the problem of the
measured results is low under the certain high temperature conditions.
Specification
«Method:GC-FID
«Measuring Range: 0.01ppm~1000ppm(CH )4
«Distinguishability:0.001ppm
«Qualitative Repeatability:RSD ≤1.0%7
«Quantitative reproducibility:RSD ≤1.0%7
«Range Drift:≤3.0%(4h)
«Oven temperature stability: ≤5℃
«Measurement Period: 2mins~30mins(the time will
change according to different component separation
columns)
«Size:482.6mm×258mm×560mm
«Display:touch LCD screen
«Communication Output:10/100M ethernet port , RS232
«Communication Protocol:Modbus-RTU/TCP
«Power Supply: 220VAC, 50Hz~60Hz, 900W
Feature
v
up the component screening and analysis
vGas line is inert processed to avoid the adsorption and residue of samples on the pipe wall
vSoftware in addition to the built-in default analysis method, also allows the user to free configure analysis
process and methods
vConfiguration supports multiple detectors which can be used for complex sample analysis at the same time
and can improve the ability of analysis
vSupport TCP/IP network remote control workstation
After completion of each sample, analyzer automatically counter blows the chromatographic columnto speed
ApplicationApply to emissions of volatile organic compounds monitoring by the end of the manufacturing industry such as
crude processing, textile and dyeing, chemical and pharmaceutical, metal smelting, etc.
Name GCOM-3000 VOCs Volatile Organic Compounds Online Monitoring System
Classification Gas Emission Continuous Monitoring
Description
GCOM-3000 volatile organic compounds online monitoring system has three basic parts: the volatile organic
compounds monitoring subsystem, flue gas parameter monitoring subsystem, system control and data acquisition and
processing subsystem. It can monitor Organic pollutant gases such as methane, the total hydrocarbon, non methane total
hydrocarbon, low-carbon aldehyde ketone, benzene series(benzene, toluene, xylene, ethyl benzene, isopropyl benzene)
and part of halogenated hydrocarbons,also the parameter such as humidity, temperature, pressure and flow rate of the
flue gas. After dedusting by sampling probe, sampling by heating pipe, dehydration and cooling by two-step
condensing, the measured gas is analyzed by the heated gas anal-ysis module (GC-FID). For the situation of high
boiling point organic pollutant gas monitoring, it can effectively avoid the absorption loss in the process of sample
collection and transmission, alsomake sure the excellent performance and stability in sample collection, analysis, data
upload and maintain links.
Specification
«Range: 0~1000ppm (customizable)
«Temperature:0℃~300℃(customizable)
«FlowVelocity: 0 m/s~40m/s (customizable)
«Pressure: -10kPa~+ 10kPa (customizable)
«Size:800mm×800mm×2000mm
«Heating Temperature:120℃~180℃
«Enclosure Protection:cabinet IP42, others IP65
«Comm. output: RS485/RS232(customizable)
«Power:220VAC, 4000W
«Working Temperature:-10℃~+45℃
«Working Humidity: (5~95)%RH(non-condensing)
«Compressed Air Requirement: (0.4~ 0.8)MPa,
clean, without oil
Feature
v
v
v
Sampling and analysis gas path have automatic control device with independent reverse blowing. It can overcome the
effect of sample gas residue and lagon analysis
Analysis is heat traced all the way to avoid the condensing and loss of high boiling point sample in pneumatic
Compact structure, convenient to use and maintenance, high reliability
ApplicationApply to manufacturing industry such as crude processing, textile and dyeing, chemical and pharmaceutical,
metal smelting, etc.
Model Name GCOM-4000-VOCs Water Volatile Organic Compounds Online Analyzer
Classification Water Pollution Continuous Monitoring
Description
GCOM-4000-VOCs consist of headspace sampling module and high temperature chromatographic analysis
modules(GC-FID). It can monitor volatile organic compounds such as section benzene series(benzene, toluene, xylene,
ethyl benzene, isopropyl benzene) in industrial wastewater and the surface water and part of halogenated hydrocarbons.
After the pipe pretreatment, water is pumped into the top of the analyzer empty pool, in the condition of constant
temperature heating,volatile organic compounds in water samples are transferred to the gas phase space on the surface
of the liquid. After inflating and decompression of carrier gas,sample gas is evaporating out and then transferred to high
temperature chromatographic analysis module for testing. By headspace sampling device of liquid to gas phase process,
direct measurement of volatile out clean gas overcome the effect of impurities such as suspended solids in water
samples on analytic flowpath.
Specification
«Method:GC-FID
«Range: 0~100mg/L
«Distinguishability:0.001mg/L
«Repeatability:±2%
«Accuracy:±10%
«Measurement Period:≤1h
«Insulation Resistance: 20MΩ
«Signal Output: RS232/485
«Communication Protocol:Modbus-RTU/TCP
«Size:600mm×800mm×1600mm
«Enclosure Rating:cabinet IP42, others IP65
«Power:220VAC, 500W
«Working Temperature:-20℃~+50℃
«Working Humidity: 5% RH~95%RH (non-condensing)
«Compressed Air Requirement: (0.4~ 0.8)MPa, clean,
without oil
«Working Carrier Gas:nitrogen, purity≥99.999%
Feature
v
component screening and analysis
It use headspace sampling module to reduce the interference of impurity on water effectively
Gas line is inert processed to avoid the adsorption and residue of samples on the wall
FID detector has a function of automatic judge and automatic ignition after outfire
Software in addition to the built-in a default analysis method, also allows the user to free configure analysis process
and methods
After completion of each sample, analyzer automatically counter blows the chromatographic column to speed up the
v
v
v
v
09 en.zetian-tech.com
Gas Emission Continuous Monitoring
Name HM-200 H ygronom Module
Classification Gas Emission Continuous Monitoring
Description
HM-200 high temperature wet & oxygen transmitter is based on microprocessor as the core, with variable
frequency ion type oxygen sensor as measuring unit. Heating pipes can be installed in the outlet of CEMS
sampling heating pipes. Flue gas gets into HM-200 by diffusion mode. Signal of humidity and temperature
output through the 4-20mA or RS485.
Specification
«Humidity:0~40%Vol
«Temperature:0~300℃
«Accuracy:0~40% H O: ±1%F.S.2
«Flue Gas Temperature:<300℃
«Working Temperature:-10℃~+50℃
«Sensor Life: > 2 years
«Transmitter Life: >5 years
«Response Time: <30s(T )90
«Signal Output: 2×4-20mA (load 250Ω) , 1×RS232
«External Inputs (2 groups): (9 ~ 28) VDC external
control signal
«Power: 24VDC, 30W ~ 31W, 35W(max) (heating)
«Weight:approximately 2.25kg(net weight)
Name HM-100 Hygronom(RC)
Classification Gas Emission Continuous Monitoring
Description
Humidity analyzer is also known as moisture or dew point analyzer for measuring pollutant emissions flue gas
humidity with wet gas concentration being converted to dry gas concentration, also can be used for industrial
on-line moisture monitoring. HM-100 can be installed directly through the flange to the flue or chimney. Signal
of humidity and temperature output through the 4-20mA or RS485.
Specification
«Humidity:0~40%Vol(optional)
«Temperature:0~180℃
«Accuracy:±2%F.S.
«Response Time:<6s(T )90
«Limit of Flue Gas Temperature:<180℃
«Working Temperature:-10℃~+55℃
«The Life of Humidity Capacitor:>5 years
«Signal Output: 2×4-20mA(load 500Ω) , 1× RS232
«Humidity Alarm Output:2 relay output, Stem node
capacity 125VAC, 0.5A
«Power:220VAC, 40W
Featurev
v
v
Core components imported, high performance, high reliability
Probe heated to prevent sensor damaged by condensation
Numeric processing, strong anti-interference
Application
Apply to the detection of medium humidity, it can be widely used in the measurement and control process of
printing and dyeing, steaming, drying, tobacco, wood, paper industry humidity; chemicals, pharmaceuticals,
fibers, textile industry; tobacco, vegetable, food processing, etc.. At the same time, it is also available for the
monitoring and control of soot emission, flue gas desulfurization and dedusting applications with CEMS.
Specification
«Flow: 0~15m/s 0~40m/s (customizable)
«Temperature:0~300℃ 0~800℃
«Pressure:-10kPa~+10kPa(customizable)
«Measuring Accuracy:±2%F.S.
«Response Time:<1s
,
,
«Signal Output:3×4-20mA, 1×RS485, 1×RS232
«Material of Pitot Tube:316L steel、PTFE (optional)
«Power Supply of Blowback Electromagnetic Valve:
220VAC 50Hz
«Limit of Differential Press. Transmitter
,
:10MPa
Feature
v
v
v
v
v
Ultra-high-precision pressure sensor achieves the low-flow(
Overvoltage protection effectively avoids pressure sensor being damaged and reducing operating costs
Strengthen o
measurement of 2m/s)
utput signal protection
LCD operating unit provides good human-machine interaction interface
Timing backblow time, velocity field parameters and Pitot tube coefficient can be set
ApplicationApply to velocity ,temperature, pressure of high temperature, humidity and dusty gas in a variety of boiler,
furnace flue and mine exhaust pipes.
Feature
vConfiguration supports multiple detectors which can be used for complex sample analysis at the same time and can
improve the ability of analysis
Support TCP/IP network remote controlling workstation
Can be equipped with explosion-proof instrument racks
v
v
ApplicationApply to volatile organic compounds monitoring include wastewater from the end of the manufacturing industry such
aspaint, resin, dye, ink, medicine, and also centralized drinking water and surface water.
Name PT-500H High-Precision Integration Monitor of Temp., Press. and Flow
Classification Gas Emission Continuous Monitoring
DescriptionPT-500 is designed for low flow rate (2m/s~5m/s) applications. The instrument uses precision micro-differential
pressure/static press. sensor and unique pitot tube structural design, combined with auto. cal. and cleaning. It can be
widely used for real-time and continuous measurements of flue gas temp., press., and flow rate as well as flow quantity.
10 en.zetian-tech.com
Gas Emission Continuous Monitoring
Name GSP-100 Sampling Probe
Classification Gas Emission Continuous Monitoring
Description
The unique sampling probe design is applied to a variety of working conditions (high temperature, high
humidity, high dust, high corrosion, etc.), supported with a variety of sampling tube, filter, heating units,
etc..It has the feature of large filter area and capacity, good air tightness, high filtration precision, leak-proof
design, low gas resistance; high precision temperature control, temperature overload protection, reliable
operation, fast response, easy installation and maintenance.
Specification
«Sampling Temperature:≤600℃
«Sampling Chamber Heating Temp.:120℃±10℃
«Filtration Precision:2μm
«Temperature Accuracy:±0.5℃
«Working Temperature:-10℃~+60℃
«Dielectric Strength:GB 6587.7
«Blowback gas source:(0.4~0.8)MPa N , 2
clean instrument air
Feature
v
v
v
v
Titanium alloy filter provides high corrosion resistance in high humidity, high temperature environment
Unique internal structure design reduces effectively the dead space of the sample gas
Filter uses a sintered alloy to filter 2μm and more dust particles and small gas resistance
Efficient inside and outside blowback structure design can effectively remove the dust, avoid congestion,
reduce daily maintenance
ApplicationApply to continuous acquisition of exhaust gas samples after the combustion process, typically high dust and
moisture content of the sample gas collection in power plant flue gas, cement production process
Name GSP-200 Sampling Probe(High-temperature)
Classification Gas Emission Continuous Monitoring
Description
GSP-200 high temperature sampling probe is an unique design product for the flue gas containing high dust
and NH HSO at temperatures below 190℃crystalline solid cause clogging of piping in the field of escaping 3 4
ammonia. It is applied to a variety of working conditions (high temperature, high humidity, high dust, high
corrosion, etc.), supported with a variety of sampling tube, filter, heating units, etc..It has the feature of large
filter area and capacity, good air tightness, high filtration precision, leak-proof design, low gas resistance;
high precision temperature control, temperature overload protection, reliable operation, fast response, easy
installation and maintenance.
Featurev
v
Core components imported, high performance, high reliability
vProbe heated to prevent humidity capacitance and thermal resistance damaged by the flue condensate
Pioneered new way of tracing pipeline installation, convenient installation and maintenance
Application
Apply to the determination of medium humidity, it can be widely used in the measurement and control process
of printing and dyeing, steaming, drying, tobacco, wood, paper industry humidity; chemicals, pharmaceuticals,
fibers, textile industry; tobacco, vegetable, food processing, etc.. At the same time, it is also available for the
monitoring and control of soot emission and flue gas deSOx and dedusting with CEMS.
Name HM-300 H ygronom
Classification Gas Emission Continuous Monitoring
Description
HM-300 high temperature wet & oxygen transmitter is based on microprocessor as the core, with variable
frequency ion type oxygen sensor as measuring unit. Dry-wet method through zirconia oxygen detector to
determine the wet oxygen content and obtain the dry oxygen content after dehydration by oxygen sensor in flue
gas analyzer, flue gas humidity can be obtained according to the standard conversion method, simple operation,
easy installation and maintenance.
Specification
«Humidity:0~40%Vol
«O : 0~25% 2
«Accuracy:
0~1% O : ±1.5%F.S.2
0~25% O : ±1.5% of the measuring value2
0~40% H O: ±1%F.S.2
«Flue Gas Temperature:<300℃
«Sensor Life: > 2 years
«Transmitter Life: >5 years
«Response Time: <30s(T )90
«Signal Output: 2×4-20mA (load 250Ω) , 1×RS232
«External Inputs (2 groups): (9 ~ 28) VDC external
control signal
«Power: 220V, 200W, 300W(max) (heating)
«Weight:approximately 32kg(net weight)
Feature
vCore components imported, high performance, high reliability
vProbe use special material, make it stronger corrosion resistance ability
vHigh protective instrument shell
vStandard flange installation, making installation easy and convenient
vSimple operation, long service life and easy maintenance
Application
Widely used in flue gas on-line continuous monitoring system CEMS flue gas humidity measurement, can also
be applied to wood, building materials, paper making, chemical, pharmaceutical, fiber, textile, tobacco,
vegetables, food processing of humidity measurement and control;The moisture meter can also be used in
ceramic dry kiln, electrode drying oven and high temperature environment of humidity measurement
11 en.zetian-tech.com
Gas Emission Continuous Monitoring
Name MS-1000 Dust Monitoring Device(Backword scattering)
Classification Particulate Matter Monitoring
Description
It is an self-developed on-line dust monitoring device, which uses the mainstream technology of laser back
scatter measurement with imported core components. MS - 1000 is mainly used for all kinds of the continuous
monitoring of the concentration of the particulate matter pollution emissions to achieve single point/multipoint
continuous smoke detection, also can be equipped with continuous monitoring system (CEMS), provides real-
time dust measurement data.
Specification
«Range: ~ ~ ( )
«Indication Error:≤±20%
«Span Drift:±2%F.S.
«Enclosure Protection:IP66
«Flue Diameter: . ~ ( )
«Power:<3W
3 3 0 500mg/m , 0 10g/m customizable
0 5m 15m customizable
«Analog Output:1×4-20mA, maximum load 800Ω
«Communication Interface:RS485,
«Working Temperature:-20℃~+45℃
«Flue Gas Temp. <
«Human-computer Interaction: upper-computer
software
2 relay outputs
: 500℃ (higher temperature need
to be customized)
Feature
v
v
In-situ zeroing and span calibration
vAutomatic gain control function and temperature compensation
vSmart appearance, easy installation, convenient disassembly
Without background light influence
ApplicationApply to the monitoring and control of soot emission and flue gas desulfurization and application of power
generation boilers, industrial furnaces, industrial boilers in the thermal power, iron and steel metallurgy,
petrochemical, chemical, cement, ceramics, waste incineration.
Specification
«Sampling Temperature:≤600℃
«Sampling Chamber Heating Temperature:(120±10)℃
«Enclosure Protection: IP65
«Filtration Precision:2μm
«Temperature Accuracy:±0.5℃
«Working Temperature:-10℃~+60℃
«Insulation Resistance:≥20MΩ
«Leakage Current:≤5mA
«Dielectric Strength:GB 6587.7
«Blowback Gas Source:(0.4~0.8)MPa N , 2
clean instrument air
Feature
vTitanium alloy filter provides high corrosion resistance in high humidity, high dust environment
vUnique internal structure design effectively reduces the dead space of the sample gas
vFilter uses a sintered alloy to filter 2μm and more dust particles and small gas resistance
vEfficient inside and outside blowback structure design can effectively remove the dust, avoid congestion,
v reduce daily maintenance
ApplicationApply to continuous acquisition of exhaust gas samples after the combustion process, typically high dust and
moisture content of the sample gas collection in power plant flue gas, cement production process
Name GSP-300 Sampling Probe(Flame-proof)
Classification Gas Emission Continuous Monitoring
Description
GSP-300 explosion-proof sampling probe is for the explosion-proof occasions. It is applied to a variety of
working conditions (high temperature, high humidity, high dust, high corrosion, etc.), supported with a variety
of sampling tube, filter, heating units, etc..It has the feature of large filter area and capacity, good air tightness,
high filtration precision, leak-proof design, low gas resistance; high precision temperature control, temperature
overload protection, reliable operation, fast response, easy installation and maintenance.
Specification
«Sampling Temperature:≤600℃
«Sampling Chamber Heating Temp.:120℃~220℃
«Filtration Precision:2μm
«Temperature Accuracy:±0.5℃
«Working Temperature:-10℃~+60℃
«Insulation Resistance:≥20MΩ
«Leakage Current:≤5mA
«Dielectric Strength:GB 6587.7
«Blowback Gas Source:(0.4~0.8)MPa N ,2
clean instrument air
Feature
vTitanium alloy filter provides high corrosion resistance in high temperature, high dust environment
vUnique internal structure design effectively reduces the dead space of the sample gas
vFilter uses a sintered alloy to filter 2μm and more dust particles and small gas resistance
vEfficient inside and outside blowback structure design can effectively remove the dust, avoid congestion,
reduce daily maintenance
ApplicationApply to continuous acquisition of exhaust gas samples after the combustion process, typically high dust and
moisture content of the sample gas collection in power plant flue gas, cement production process
Name DMS-100 Dust Monitoring Device(Backword scattering)
Classification Particulate Matter Monitoring
DescriptionIt is an self-developed on-line dust monitoring device, which uses the mainstream technology of laser back
scatter measurement with imported core components. DMS - 100 is mainly used for all kinds of the continuous
monitoring of the concentration of the particulate matter pollution emissions to achieve single point/multipoint
12 en.zetian-tech.com
Gas Emission Continuous Monitoring
Descriptioncontinuous smoke detection, also can continuous monitoring system (CEMS),
time dust measurement data.
be equipped with provides real-
Specification
«Range: ~ ~ ( )
«Indication Error:≤±20%
«Span Drift:±2%F.S.
«Enclosure Protection:IP66
«Flue Diameter: . ~ ( )
«Power:<3W
«Flue Gas Temp.
3 3 0 500mg/m , 0 10g/m customizable
0 5m 15m customizable
:500℃ (higher temperature need
to be customized)
«Analog Output:1×4-20mA, maximum load 800Ω,
2×4-20mA(optional)
«Communication Interface:RS485(optional),
(optional)
«Working Temperature:-20℃~+45℃
«Human-computer Interaction: infrared remote
control+large-screen LCD display
2 relay
outputs
Feature
v
v
v
In-situ zeroing and span calibration
vAutomatic gain control function and temperature compensation
vSmart appearance, easy installation, convenient disassembly
Without background light influence
Support infrared remote control function
ApplicationApply to the monitoring and control of soot emission and flue gas desulfurization and application of power
generation boilers, industrial furnaces, industrial boilers in the thermal power, iron and steel metallurgy,
petrochemical, chemical, cement, ceramics, waste incineration.
Name DMS-300 Dust Monitoring System
Classification Particulate Matter Monitoring
DescriptionIt is an on-line dust analysis instrument independently developed by our company, which uses the mainstream
technology of laser scatter measurement with imported core components. It is suitable for dust monitoring in
low temperature and high humidity conditions. In addition, it can be extended to space dust monitoring.
Specification
3 3 «Range: 0~ 20mg/m , 0~ 50mg/m
(c )3
«Detection Limit:0.05mg/m
«Measuring Error:±10%
«Span Drift: ±2%F.S.
«Enclosure Rating:IP54
«Power:1500W
«Sampling Flow:0~30L/min
ustomizable«Analog Output: Temp., pressure, flow rate, dust
4×4-20mA output
«Communication Interface:RS485(optional), 5×Relay
output(optional), 2A/30V, passive
«Working Temperature:-20℃~+50℃
«Max Flue Gas Temp.:<300℃
«Human-computer Interaction: OLCD display
Feature
v
measuring
vUsing large-caliber jet pump avoids clogging caused by dust accumulation, long maintenance-free period
vTemperature compensation and automatic range switching function
Dust extraction with high Temp. heat tracing makes steam gasification to avoid water vapor interfering dust
Application Apply to dust monitoring in low temperature and high humidity conditions, the workshop dust monitoring
Name DMS-200 Dust Monitoring Device
Classification Particulate Matter Monitoring
DescriptionDifferent from DMS-100, DMS-200 is installed on the probe, access to the flue pipe through the probe directly
to realize flue dust measurement, so it is possible to achieve very low detection limits. It is widely used in dust
monitor of thermal power generation and other ultra-low emissions industries.
Specification
3 3 «Range:0~10mg/m , 0~200mg/m (m )
«MeasuringError:±10%
«Span Drift:±2%F.S.
«Enclosure Protection:IP65
«Flue Diameter:1m, 15m( )
ax
customizable
«Analog Output: 1× 4-20mA , 1× Relay
output(optional), 2A/30V
«Communication Interface:RS485(optional)
«Working Temperature:-40℃~+50℃
«Flue Gas Temp.:<250℃
Feature
v
v
v
v
30.005mg/m low detection limit meets ultra-low emission on-line monitoring requirements
Air curtain purging protects glasses, long maintenance-free period
Without external light influence, development of space dust detection can be realized
Analyzer uses a special structure to achieve ultra-short optical path measurement, no adjusting of optical path
according to the working conditions needed
ApplicationApply to online monitoring of low concentrations dust in super clean emissions and development of space dust
detection.
13 en.zetian-tech.com
Gas Emission Continuous Monitoring
Name CODet-5000 CODcr Water Quality Online Automatic Analyzer
Classification Water Pollution Continuous Monitoring
Description
CODet-5000 is a new type of water quality on-line automatic analyzer for measuring chemical oxygen demand
(COD), this product based on the global initiative magnetic conductivity measurement platform, combined with
constant optical fiber, dispelling colorimetric integration technology, COD automatic online monitoring have the
features include high precision, low detection limit, high stability and low maintenance quantity. This product
works in accordance with the technical requirements of 《HJ/T 399-2007 water quality the measurement of
chemical oxygen demand-digestion spectrophotometric method》 , fully meet the pollution sources, municipal
wastewater, industrial processes in the application areas, and has passed the certification of CMC and CCEP.
Specification
«Method: fast digestion spectrophotometric
«Range:10~1000~5000mg/L (customizable)
«Indication Error: ±10%
«Repeatability: ≤5%
«Zero Error: ±5mg/L
«Span Drift: ±10%
«Detection Limit: 10mg/L
«Digestion Time:3、5、20、30、40、60、80、
100 or120min
«Interval:continuous, 1, 2, 3... 24 hours, can also
be triggered by a serial port
«Reagent Consumption: a single set of reagents can
measure 250 samples(12 samples/day calculated)
«Analog Input: 4-20mA input (expandable to 2-channel),
compatible with 0-5V input
«Analog Output: 4-20mA output (expandable to 2-channel),
the maximum load 500Ω
«Relay Output: 4relay output can be flexible configuration)
«Communication Interface:RS485/RS232/USB interface
(optional)
«Maintenance Work: <1h/month
«Working Temperature: 5℃~45℃
«Power Consumption: 200W, without considering pumps
«Power: 220±10%VAC, 50-60Hz
Feature
vMagnetic conductivity measurement technology do not affect by chromaticity, suspended solids and bubbles,
especially suitable for the monitoring of inlet water
vHigh accuracy and reliability, strong anti-interferance capability
vHigh precision, low detection limit(10mg/L), small amount of instrument drift for a long time
vHas a key self-check function and self diagnosis function
vImported single-channel high integration valve island, simple and easy to maintenance, dismantling and
cleaning
vAll-day networking, monitoring meter running state at anytime and anywhere
vHigh intelligent level
vContain the scan code function, alarm function, quality control and reverse control functions at the same time
Application Apply towater pollution monitoring, industrial process water, industrial,municipal wastewater treatment and other fields.
Name WDet-5000 Ammonia-Nitrogen Water Quality Online Automatic Analyzer
Classification Water Pollution Continuous Monitoring
Description
WDet-5000 provide two plans: nessler's reagent colorimetric method and salicylic acid method. This product based
on the global initiative magnetic conductivity measurement platform, combined with constant optical fiber,
dispelling colorimetric integration technology, ammonia-nitrogen automatic online monitoring have the features
include high precision, low detection limit, high stability and low maintenance quantity. This product works in
accordance with the technical requirements of 《HJ 535-2009 water quality the measurement of ammonia-
nitrogen - nessler's reagent colorimetric method》 and 《HJ/T 535-2009 water quality the measurement of
ammonia-nitrogen - salicylic acid method》, fully meet the pollution sources, municipal wastewater, industrial
processes in the application areas, and has passed the certification of CMC and CCEP.
Specification
«Method Nessler's reagent colorimetric method Salicylic acid method
«Range 0.2~50/300mg/L 0.01~2/10/100mg/L
«Indication Error ±10%
«Repeatability ±3%F.S. ±5%F.S.
«Zero Drift ≤0.02mg/L
«Span Drift ≤2%F.S.
«Interval Automatically adjusted
«Period Minimum measurement period 15minutes
«Maintenance <2 hours/month
«Reagent Consumption A single set of reagents can measure 250 samples(12 samples/day calculated)
«Working Temp. 5℃~45℃
«Relay Control 4, can be flexibly configured
«Power 100W(220VAC,50Hz) 200W(220VAC,50Hz)
«Analog Input 4-20mA input (expandable to 2-channel), compatible with 0-5V input (optional)
«Analog Output 4-20mA output (expandable to 2-channel), the maximum load 500Ω
«Communication Interface RS485/RS232/USB interface (optional)
14
Water Pollution Continuous Monitoring
en.zetian-tech.com
Name WDet-5000 Total N itrogen Water Quality Online Automatic Analyzer
Classification Water Pollution、Surface Water Continuous Monitoring
Description
WDet-5000 is a new type of water quality on-line automatic analyzer for measuring , this product
based on the global initiative magnetic conductivity measurement platform, combined with constant optical
fiber, dispelling colorimetric integration technology, automatic online monitoring have the
features include high precision, low detection limit, high stability and low maintenance quantity. This product
works in accordance with the technical requirements of 《GB 11894-1989 water quality the measurement of
-Alkaline potassium persulfate digestion-UV spectrophotometry method》 , fully meet the
pollution sources, municipal wastewater, industrial processes in the application areas, and has passed the
certification of CCEP.
total nitrogen
total nitrogen
total nitrogen
Specification«Method:Alkaline potassium persulfate digestion -
UV spectrophotometry
«Range: 0~50mg/L(customizable)
«Interval:Continuous, 1, 2, 3... 24 hours, can also
be triggered by a serial port
Classification Water Pollution 、Surface Water ContinuousMonitoring
Description
WDet-5000 is a new type of water quality on-line automatic analyzer for measuring , this
product based on the global initiative magnetic conductivity measurement platform, combined with constant
optical fiber, dispelling colorimetric integration technology, automatic online monitoring have
the features include high precision, low detection limit, high stability and low maintenance quantity. This
product works in accordance with the technical requirements of 《 GB 11893-1989 water quality the
measurement of -ammonium molybdate spectrophotometry method》 , fully meet the pollution
sources, municipal wastewater, industrial processes in the application areas, and has passed the certification of
CCEP.
total phosphorus
total phosphorus
total phosphorus
Specification
«Method Ammonium molybdate spectrophotometry method
«Range 0.05~2/5/10mg/L
«Detection Limit 0.05mg/L
«Repeatability ≤5%
«Zero Drift ±5%F.S.
«Span Drift ±10%F.S.
«Interval Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
«Reagent Consumption A single set of reagents can measure 250 samples(12 samples/day calculated)
«External InterfaceAnalog Input:1-channel 4-20mA input (expandable to 2-channel), compatible with
0-5V input (optional)
«Working Temp. 5℃~45℃
«Maintenance <2 hours/month
«Power 200W(220VAC,50Hz),without considering pumps
Feature
vMagnetic conductivity measurement technology do not affect by chromaticity, suspended solids and bubbles,
especially suitable for the monitoring of inlet water
vHigh accuracy and reliability, strong anti-interferance capability
vHigh precision, low detection limit(0.1mg/L), small amount of instrument drift for a long time
vHas a key self-check function and self diagnosis function
vImported single-channel high integration valve island, simple and easy to maintenance, dismantling and
cleaning
vAll-day networking, monitoring meter running state at anytime and anywhere
vHigh intelligent level
vContain the scan code function, alarm function, quality control and reverse control functions at the same time
ApplicationApply to the monitoring of pollution sources and surface water,can also be applied to the detection of the
sewage treatment process.
15
Water Pollution Continuous Monitoring
en.zetian-tech.com
Feature
v
inlet
v
v
v high
v anytime and anywhere
vHigh i
v
Magnetic conductivity measurement technology do not affect by chromaticity, suspended solids and bubbles,
especially suitable for the monitoring of water
High precision, low detection limit(0.01mg/L), small amount of instrument drift for a long time
Has a key self-check function and self diagnosis function
Imported single-channel integration valve island, simple and easy to maintenance, dismantling and cleaning
All-day networking, monitoring meter running state at
ntelligent level
Contain the scan code function, alarm function, quality control and reverse control functions at the same time
ApplicationNessler's reagent colorimetric method is used in sewage treatment plants exports and other monitoring occasions,
Salicylic acid method can be widely used in monitoring of ammonia-nitrogen in water samples of surface water
environment, industrial depth processing.
Name WDet-5000 Total PhosphorusWater Quality Online Automatic Analyzer
Name MDet-5000X Heavy Metal Water Quality Online Analyzer
Classification Water Pollution Continuous Monitoring
Description
WDet-5000X is a new on-line automatic analyzer for heavy metal content measuring. The instrument through
precise control related chemical reaction. The instrument uses the latest technology such as optical
measurement,high temperature and high pressure digestion, color integration, etc, has the feature of accurate
measurement, low detection limit, high reliability and good adaptability, etc. It complies with the relevant
testing standards issued by the State Environmental Protection Agency, and received a certificate of the relevant
state departments of environmental protection. Reagent used by the instrument can be formulated according to
the national standard(the required reagent is different according to measurement occasions, measuring
components, the specific operating mode needs can be consulted by company technical support).
Specification
«Method:
potassium permanganate oxidation-diphenylcarbo-
hydrazide spectrophotometric(TCr);6+ Diphenylcarbohydrazide spectrophotometric(Cr );
Cold atomic spectrophotometry(Hg);
Zinc reagent spectrophotometry(Zn);
Formaldehyde oxime spectrophotometr ic
method(Mn);
«Span Drift: ±10%F.S.
«Detection limit:0.05mg/L
«Interval:Continuous, 1, 2, 3... 24 hours, can also be
triggered by a serial port
«Maintenance Work: < 1h/month
«Reagent Consumption: a single set of reagents can
measure 250 samples(12 samples/day calculated)
«Working Temperature:5℃~ 45℃
ApplicationApply to the monitoring of content in surface water when the chloride ion concentration
bellows 300 mg/L and the monitoring of water from drinking water source, surface water such as lakes and
rivers, tap water factory and city pipe network.
Permanganate Index
16
Water Pollution Continuous Monitoring
en.zetian-tech.com
Name WDet-5000Mn Permanganate Index Water Quality Analyzer
Classification Water Pollution、Surface Water Continuous Monitoring
Description
Instrument use the acidic potassium permanganate spectrophotometry to measure the organic matter content of
water.Theorganic matter in the water is dispelled andoxidized by the acidic potassium permanganate at the
temperature of 95℃.The amount of residual potassium permanganate is measured in 535 nm. The decrement of
potassium permanganate is proportional to the consumption of organic matter.
Specification
«M e t h o d : p o t a s s i u m p e r m a n g a n a t e
spectrophotometry
«Range: 0 ~ 5~10~20mg / L, adjustable
«Indication Error: ±10%
«Repeatibility: ≤5%
«Zero Drift: ±5%F.S.
«Span Drift: ±10%F.S.
«Detection Limit:0.5mg/L
«Reagent Consumption:a single set of reagents can
measure 250 sample(12 samples/day calculated)
«Maintenance: <2hour/month
«Interval:Continuous, 1, 2, 3... 24 hours, can also be
triggered by a serial port
«Analog Input:4-20mA input (expandable to
2-channel)(compatible with 0-5V input (optional))
«Analog Output:4-20mA output (expandable to 2-
channel), the maximum load 500Ω
«Relay Outputs: 4, flexible configuration
«Communication Interface: RS485/RS232/USB
interface (optional)
«Power:200W(220VAC, 50Hz)
Feature
vCore components imported, high reliability, long lifetime, suitable for long time on-line monitoring
vPhotoelectric measurement method makes accurate sampling with low injection error
vUnique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
vAutomatic leakage alarm and self-diagnostic function enhance safety and efficiency
Specification
«Indication Error: ±10%
«Repeatibility: ≤5%
«Zero Drift: ±5%F.S.
«Span Drift: ±10%F.S.
«Detection limit:0.2mg/L
«A single set of reagents can measure 250 samples(12
samples/day calculated)
«Working Temp.:5℃~45℃
«Analog Input: 1-channel 4-20mA input
(expandable to 2-channel)
«Analog Output: 1-channel 4-20mA output
(expandable to 2-channel), the maximum load 500Ω
«Relay Outputs: 4-channel, flexible configuration
«Communication Interface: RS485/RS232/USB
interface (optional)
«Power:200W(220VAC, 50Hz)
Feature
vMagnetic conductivity measurement technology do not affect by chromaticity, suspended solids and bubbles,
especially suitable for the monitoring of inlet water
vHigh accuracy and reliability, strong anti-interferance capability
vHigh precision, low detection limit(0.2mg/L), small amount of instrument drift for a long time
vHas a key self-check function and self diagnosis function
vImported single-channel high integration valve island, simple to maintenance, dismantling and cleaning
vAll-day networking, monitoring meter running state at anytime and anywhere
vHigh intelligent level
vContains scan code function, alarm function, quality control and reverse functions at the same time
Application Apply to the monitoring of environmental pollution, industrial process water, municipal wastewater treatment.
Specification
The new silver salt spectrophotometry(Ag);
Spectrophotometric method(As);
Copper bath spirit colorimetric method(Cu);
Dimethylglyoxime spectrophotometry(Ni);
Porphyrin reagents color spectrophotometry(Pb)
Formaldoxime Spectrophotometry(TMn)
O-phenanthroline spectrophotometric(TFe)
«Range: customizable
«Indication Error: ±10%
«Repeatibility: ≤5%
«Zero Drift: ±5%F.S.
«Analog Output: 4-20mA output (expandable to 2-
channel), the maximum load 500Ω
«Analog Input: 4-20mA input (expandable to 2-
channel), compatible with 0-5V input
«Relay Output: 4, flexible configuration
«Switch Input: 2, flexible configuration
«Communication Interface: RS485 / RS232 / USB
interface(optional)
«Power Consumption: 200W (220VAC, 50Hz),
regardless of the pump
Feature
vHigh reliability, small amount of maintenance
Core components imported, high reliability, Long lifetime, suitable for long time on-line monitoring
Using photoelectric measurement method and special measuring algorithm
All parts contacted with liquid before delivery will havea special test to ensure that these parts can be used
for a long time.
Flow path is not easy to jam through the special design
Accurate measurement, wide application scope
Photoelectric measurement method,sample accurately,low injection error
Automatic chromaticity and turbidity compensation algorithm, give full consideration to the situation of
actual samples, real and reliable monitoring results
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
afe use, efficient analysis
When a reagent leakage, instruments and automatic will alarm and prompt the user for maintenance
Equipment has self-diagnosis function, if there is a defective, it will automatically alarm, and display name
�
�
�
�
�
�
�
�
�
v
vS
ApplicationApply to the conditions such as mining, waste water discharge, sewage irrigation, and heavy metal pollution produced in
the process of metals production
Name MDet-6000X Anodic Stripping Heavy Metal Water Quality Online Analyzer
Classification Water Pollution Continuous Monitoring
Description
Analyzer uses electrochemical anodic stripping voltammetry which isranked by the US EPA of authority as a
standard test method.Stripping voltammetry is also called reverse stripping polarography,which make the
material being measured, Electrolytic a certain amount of time under the ion polarographic analysis of limiting
current potential test. Then change the electrode potential, make the material concentrated on the electrode to be
dissolved. According to the given volt-ampere curve in the dissolution process for quantitative analysis
Specification
«Measuring Components: cadmium, lead, zinc,
copper, mercury, arsenic
«Method: anodic stripping voltammetry
«Indication Error: ±10%
«Repeatibility: ≤5% (100 ppb)
«Zero Drift: ±5%F.S.
«Span Drift: ±10%F.S.
«Detection Limit:0.01ppm
«Enrichment of Time: 15 s, 30 s, 200 s can be set
«Interval: continuous, 1, 2, 3...24 hours a day, or
triggered by the modbus device
«Reagent Dosage: a single set of reagents can
measure 250 samples(12 samples/day calculated)
«Size: 1460 mm×510 mm×410 mm
«Weight: 70 kg (exclusive of reagent)
«Analog Output: 4-20 mA output (can be extended to
2 channel), 2 multi-function relay output
«Preheat Time: 2h
«Working Temperature: 5℃~45℃, humidity < 95%
«Power: 220±10% for VAC, 50 Hz - 60 Hz
«Power Consumption: 100 W
«Other: automatic cleaning, data records, print,
buzzer alarm
Feature
v
v
v
v
v
v
v
v
v
A function of automatic cleaning electrode and activation, guarantee the accuracy of the measurement results
and long trouble-free operation
Strong anti-interference ability and high reliability data
Touch screen operation interface, easy and convenient
With no mercury electrode and non-toxic reagent, low reagent consumption, safe and no secondary pollution,
low operation cost.
Built-in digestion function, can better adapt to the water quality being measured
Automatic calibration, high accuracy, wide linear range
Modular design, can increase the measurement module according to user needs; can achieve a variety of
heavy metal elements simultaneously measured on a single instrument, effective cost savings for users
With a RS232 / RS485 interface and 4-20mA output interface to facilitate data collection and remote control
with intelligent fault self-diagnosis function, power protection design, unusual power, then power automatic
data recovery
17 en.zetian-tech.com
Water Pollution Continuous Monitoring
ApplicationApply to the waste water monitoring of industry such as electroplating and surface treatment industry, mining,
smelting, lead-acid batteries, leather and its products, chemical raw materials and products, water quality
monitoring of surface water, groundwater, water quality monitoring of water works, municipal pipe network.
Name PDV-5000X Portable Anodic Stripping Heavy Metal Analyzer
Classification Water Pollution Continuous Monitoring
Description
Analyzer using anodic stripping voltammetry to detect heavy metals, low detection limit (up to PPB level), high
precision, stable performance, easy to carry, especially suitable for field site operation.Widely used
inmonitoringheavy metal content in the water of soil, food, solid material, drinking water, surface water,
beverage, water environment, seawater, industrial waste water.
Specification
«Measuring components: cadmium, lead, zinc,
copper, mercury, arsenic
«Method: the anodic stripping voltammetry
«Range: 0~10 ppm
«Indication Error: ±10%
«Repeatibility: ≤5%(100ppb)
«Zero Drift: ±5%F.S.
«Span Drift: ±10%F.S.
«Detection Limit:0.01ppm
«Time: 15 s and 60 s, 200 s can be set
«Battery Life: without external power supply,
built-in lithium battery measurement can
measure 4 hours continuously
«Warm-up time: 2 hours
«Reagent Dosage: take reagent support 50 sample
measurement, optional reagent kit
«Electrode Maintenance: depending on the sample
analysis cycle
«Signal Output: bluetooth
«Communication Interface: RS485/RS232/USB interface
(optional)
«Whole Case Weight: 5.3 kg (including the reagent)
«Maintenance: < 1 hour/month
«Working Temp.: 5℃ ~45 ℃ , humidity<95%, no
condensation
«Preheat Time: 2h
«Power: 220VAC(In), 12V/1.5A(Out)
«Other: data record and print
Feature
v
vForm a complete set of experimental instruments, make the direct analysis possible on scene
vMultiple sets of measuring cups,it’s convenient to continuously measure a variety of samples at the same time
vDetachable electrode combination, convenient to replace and maintain
vIn addition to the default measurement method, analysis of parameters can be set freely, to facilitate the
expansion of the measurement method
240 x160 pixel LCD screen
Name WDet-5000CN Cyanide Water Quality Online Analyzer
Classification Water Pollution Continuous Monitoring
Description
Under the condition of weak acid, cyanide of water samples and chloramine T generate chloramine cyanide,and
then react with isonicotinic acid, after the hydrolysis generate pentene dialdehyde,finally, together with
barbituric acid generate purple blue compounds,in a certain concentration range, the chroma is proportional to
the concentration of cyanide.
Specification
«Method: isonicotinic acid - barbituric acid
spectrophotometry
«Range: 0 ~ 1~ 2~ 5mg/L(customizable)
«Indication Error: ±10%
«Repeatibility: ≤5%
«Zero Drift: ±5%F.S.
«Span Drift: ±10%F.S.
«Detection Limit:0.05mg/L
«Reagent Consumption:a single set of reagents can
measure 250 samples(12 samples/day calculated)
«Interval:Continuous, 1, 2, 3... 24 hours, can also
be triggered by a serial port
«Analog Input:4-20mA input (expandable to
2-channel)(compatible with 0-5V input)
«Analog Output:4-20mA output (expandable to
2-channel), the maximum load 500Ω
«Communication Interface: RS485/RS232/USB
interface (optional)
«Working Temp.:5℃~45℃
«Power:200W(220VAC, 50Hz)
Feature
vCore components imported, high reliability, long lifetime, suitable for long time on-line monitoring
vPhotoelectric measurement method makes accurate sampling with low injection error
vUnique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
vAutomatic leakage alarm and self-diagnostic function enhance safety and efficiency
Application Apply to the cyanide monitoring of surface water, sewage and industrial wastewater.
ApplicationApply to the heavy metal content terminal analysis of sample in the laboratory. The rapid emergency of outdoor
environment accident point detection.The inspection in the process of industrial analysis.
Name WDet-5000UVI Immersion Water Quality Analyzer
Classification Water Pollution Continuous Monitoring
Description
WDet-5000UVI is the first full-spectrum (200 -800nm) immersion UV analyzer. nm Apply to measurement
COD, BOD, UV254, nitrate, TOC, DOC, turbidity, TSS, color and other indicators of surface water,
groundwater, municipal wastewater. It also can measure TSS, BOD and COD at the same time to realize three-
to-one measurement.
18 en.zetian-tech.com
Water Pollution Continuous Monitoring
Specification
«Method:DOAS
«Range:
COD, BOD: 0~100~1000mg/L
TSS: 0~50~200NTU
«Indication Error: ±10%
«Repeatibility: ≤5%
«Zero Drift: ≤±1%F.S.
«Span Drift: ≤±5%F.S.
«Detection Limit:10mg/L
«Linearity:2%F.S.
«Measuring Cycle: the shortest 60s, the cycle can
be set
«Automatic Cleaning Cycle: can be set
«Reagent Consumption:no reagent
«Maintenance: <2h/month
«Optical Drive: adjust according to field condition
« Water Temperature:5℃~45℃
« Probes Into The Water Depth:<10m
«External Interface: RS485, 4-20mA output(2-
channel)
«Probe Dimensions: φ60mm×380mm
«Enclosure Rating: IP65
«Probe Weight: 5kg
«Power:220VAC, 30W
Feature
v nm
v
v
v
v
Full spectrum (200 -800nm) measurement technique and chemometric algorithm allows more parameters
to be measured
Automatic cleaning of gas probe with high-pressure provides higher reliability than the mechanical blade
No reagents, low operating costs, no secondary pollution
Fast response(2s), applicable to real-time requirements of the occasion
Interference-free chlorine ion
ApplicationApply to measurement COD, BOD, UV254, nitrate, TOC, DOC, turbidity, TSS, color and other indicators of
surface water, groundwater, municipal wastewater.
Name WDet-5000 COD/Ammonia Nitrogen Integration Water Quality Online Analyzer
Classification Water Pollution Continuous Monitoring
Description
WDet-5000 COD/ammonia water quality analyzer is a new kind of automatic on-line analyzer used for
measuring simultaneously ammonia nitrogen and chemical oxygen demand (COD) in the water. WDet-5000
using the latest photoelectric measuring, UV-vis spectral measurement techniques, has features of accurate
measurement, high integration, low detection limit, high reliability, strong adaptability, etc. Instrument reagent
can be used on its own in accordance with the relevant national standard.
Specification
Ammonia Nitrogen COD
«Method Nessler's reagent colorimetric UV-vis spectrophotometry
«Range 0~50mg/L 0~200mg/L
«Indication Error ±10%
«Repeatability ≤5%
«Zero Drift ±5%F.S.
«Span Drift ±10%F.S.
«Detection Limit 0.01mg/L 10mg/L
«Interval Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
«Reagent Consumption A single set of reagents can measure 250 samples(12 samples/day calculated)
«External Interface
Analog Input:4-20mA input (expandable to 2-channel), compatible with 0-5V input
(optional)
Analog Output: 4-20mA output (expandable to 2-channel), the maximum load 500Ω
Relay Control:4-channel, can be flexibly configured
Communication Interface:RS485/RS232/USB interface (optional)
«Maintenance <2 hour/ month
«Working Temp. 5℃~45℃
«Power 200W(220VAC,50Hz),without considering pumps
Feature
v
v
v
v
Full spectrum (200nm-800nm) measurement techniques, can simultaneously measure ammonia nitrogen and
COD(UV method)
Photoelectric measurement method,sample accurately,low injection error
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
With automatic leakage alarm and self-diagnostic function, safety in use, efficient analysis
ApplicationApply to water pollution monitoring/industrial process water/industrial and municipal wastewater treatment and
other fields.
Name WDet-5000 TP /TN Integration Water Quality Online Analyzer
Classification Water Pollution Continuous Monitoring
DescriptionIt is a new kind of automatic on-line analyzer used for measuring simultaneously Total phosphorus /total
nitrogen in the water. WDet-5000 using the latest photoelectric measuring, uv-vis spectral measurement
19 en.zetian-tech.com
Water Pollution Continuous Monitoring
Name WDet-5000TPN TP/TN/COD Integration Water Quality Online Analyzer
Classification Water Pollution Continuous Monitoring
Description
It is a new kind of automatic on-line analyzer used for simultaneously measuring Total phosphorus, total
nitrogen and chemical oxygen demand (UV method) in the water. WDet-5000 TPN using the latest photoelectric
measuring, UV-vis spectral measurement techniques, has features of accurate meas-urement, high integration,
low detection limit, high eliability, strong adaptability, etc. Instrument reagent can be used on its own in
accordance with the relevant national standard.
Descriptiontechniques, has features of
adaptability, etc. Instrument reagent can be used on its own in accordance with the relevant national standard.
accurate measurement, high integration, low detection limit, high reliability, strong
Specification
Total Phosphorus(TP) Total Nitrogen(TN)
«Method Ammonium molybdate spectrophotometryThe alkaline potassium persulfate
digestion-UV-vis spectrophotometry
«Range 0~10mg/L 0~50mg/L
«Indication Error ±10%
«Repeatability ≤5%
«Detection Limit 0.1mg/L 0.2mg/L
«Interval Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
«Reagent A single set of reagents can measure 250 samples(12 samples/day calculated)
«External Interface
Analog Input:4-20mA input (expandable to 2-channel), compatible with 0-5V input
(optional)
Analog Output: 4-20mA output (expandable to 2-channel), the maximum load 500Ω
Relay Control: 4, can be flexibly configured
Communication Interface:RS485/RS232/USB interface (optional)
«Maintenance <2 hour/ month
«Working Temp. 5℃~45℃
«Power 200W(220VAC,50Hz),without considering pumps
Feature
v
v
v
v
Full spectrum (200-800nm) measurement techniques, can simultaneously measure ammonia nitrogen and
COD(UV method)
Photoelectric measurement method,sample accurately,low injection error
Unique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
With automatic leakage alarm and self-diagnostic function, safety in use, efficient analysis
ApplicationApply to water pollution monitoring/industrial process water/industrial and municipal wastewater treatment and
other fields.
Specification
Total Phosphorus(TP) Total Nitrogen(TN) COD
«MethodAmmonium molybdate
spectrophotometry
Molybdenum ye l low
colorimetryUV-VIS spectrophotometry
«Range 0~10mg/L 0~50mg/L 0~200mg/L
«Indication Error ±10%
«Repeatibility ≤5%
«Zero Drift ±5 F.S.%
«Span Drift ±5%F.S.
«Detection Limit 0.01mg/L 0.2mg/L 10mg/L
«Interval Continuous, 1, 2, 3... 24 hours, can also be triggered by a serial port
«Reagent Consumption A single set of reagents can measure 250 samples(12 samples/day calculated)
«External Interface
Analog Input: 4-20mA input (expandable to 2-channel), compatible with 0-5V input
(optional)
Analog Output: 4-20mA output (expandable to 2-channel), the maximum load 500Ω
Relay Control:4 ,can be flexibly configured
Communication Interface:RS485/RS232/USB interface (optional)
«Maintenance <2 hour/ month
«Working Temp. 5℃~45℃
«Power 200W(220VAC,50Hz),without considering pumps
Feature
vFull spectrum (200nm-800nm) measurement techniques, can simultaneously measure ammonia nitrogen and
COD(UV method)
vPhotoelectric measurement method,sample accurately,low injection error
vUnique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
vWith automatic leakage alarm and self-diagnostic function, safety in use, efficient analysis
20 en.zetian-tech.com
Water Pollution Continuous Monitoring
Name MDet-5000 Cr/Total Cr Integration Heavy Metal Water Quality Online Analyzer
Classification Water Pollution Continuous Monitoring
Description
In measurement of hexavalent chromium, in acid medium, hexavalent chromium of sample react
withdiphenylcarbazide whichgenerate purple compound.Compound color depth is proportional to the content of
hexavalent chromium in the samples.When measuring total chromium, first mix sample with potassium
permanganate, dispel under the situation of airtight high temperature and high pressure, then trivalent
chromiumof the sample is oxidized to hexavalent chromium.Spectrophotometric method is used to measure the
absorbance value of reaction product (hexavalent chromium),and obtain the content of the hexavalent chromium
and total chromium in the samples.
Specification
«Method: diphenylcarbazide spectrophotometry 6+(Cr ), potassium permanganate oxidation-
d i p h e n y l c a r b a z i d e s p e c t r o p h o t o m e t r y
method(TCr)
«Range: 0~1/2/5mg/L (total chromium, hexavalent
chromium), 0~0.5mg/L(hexavalent chromium)
«Indication Error: ±10%
«Repeatibility: ≤5%
«Zero Drift: ±5%F.S.
«Span Drift: ±10%F.S.
«Detection Limit: 0.05mg/L
«Reagent Consumption: A single set of reagents
can measure 250 sample(12 samples/day
calculated)
«Interval: continuous, 1, 2, 3...24 hours a day, or
triggered via a serial port
«Analog Output: 4-20mA output (expandable to 2-
channel), the maximum load 500Ω
«Analog Input: 4-20mA input (expandable to 2-
channel), compatible with 0-5V input
«Relay Output: 4, can be flex-ibly configured
«Communication Interface: RS485 / RS232 / USB
interface (optional)
«Maintenance: <2 hour/ month
«Working Temperature: 5℃~45℃
«Power: 200W(220VAC, 50Hz), without considering
pumps
Feature
vFull spectrum (200nm-800nm) measurement techniques, can simultaneously measure ammonia nitrogen and
COD(UV method)
vPhotoelectric measurement method, sample accurately, low injection error
vUnique hybrid technology of bubble agitation ensures thorough mixing of samples and reagents
vWith automatic leakage alarm and self-diagnostic function, safety in use, efficient analysis
ApplicationApply to hexavalent chromium (chromium) monitoringof industrial sewage treatment plant and industrial
process (such as electroplating, metallurgy, printing and dyeing industry), etc.
ApplicationApply to water pollution monitoring/industrial process water/industrial and municipal wastewater treatment and
other fields.
21 en.zetian-tech.com
Water Pollution Continuous Monitoring
Model Name AQMS-100 VOCs Online Monitoring System
Classification Environmental Monitoring
Description
AQMS-100 is an on-line monitoring product that measures VOCs (volatile organic compounds) content of indoor air and atmospheric. The system uses advanced intelligent component analysis algorithm and photoionization (PID) detection technology, gathering gas, processing, analysis, storage and upload real-time measurement data by high-precision AD sampling to monitor the concentration of total VOCs and the main component , the total amount of emissions in real time.
Specification«Principle: PID photoionization detection
«Measurement Error: <± 5% F.S (benzene gas).
«Transfer Protocol: HJ/T 212
«In
«Output Interface: GPRS wireless, RS485 bus
«Output Distance: 2000m(max), RS485 mode
«Humidity: 10% RH ~ 95% RH
stallation: wall-mounted or outdoor cabinet
Feature
vAdvanced pretreatment system can be adapt to high temperature, high dust and other serious environmental .vFID detector has the advantages of high sensitivity, wide linear range, high stabilityvWide detecting range is suitable for monitoring both high and low concentrations of emission.vWith automatic calibration function, the operation status of detector is for real-time monitoring that can realize remote fault diagnosis and maintenance
Application
Apply to organic industrial pollution emissions in transportation equipment manufacturing, industrial coating, packaging, printing, paint manufacturing, organic chemicals, tire manufacturing, semiconductor integrated circuits, furniture manufacturing, household appliances, wire and cable, paint dry, footwear, synthetic materials, monosodium glutamate manufacturing industrial.
Model Name AEM-1000 Atmospheric Extinction Monitoring System
Classification Environmental Monitoring
Description
It is a self-developed analysis extinction analyzer product for domestic and overseas environmental and
meteorological online monitoring and industry online analysis. The analyzer is able to measure aerosol
extinction coefficient, atmospheric visibility, air temperature and humidity simultaneous using the principle of
phase-shift spectroscopy measurements, calculate the single scattering albedo combined with integral aerosol
turbidity meter. It has high accuracy and sensitivity, stability and reliability, fast response time, a wide range of
applications.
Specification
«Method: Phase Shift Spectroscopy4 -1
«Range: 0 ~ 10 Mm (extinction coefficient),
0 ~ 200km (visibility)-1
«Detection Limit: 0.1Mm
«Extinction Coefficient uncertainty: ≤3%
«Response Time: ≤30s
«Sample Flow: <2.5L/min
«Ligth Source: LED
«Warm-up Time: None
«Digital Communications: RS485 / RS232 /
GPRS
«Explosion Rating: IP42
«Working Temperature: -5℃~ + 45 ℃
«Humidity: 0 ~ 100% RH
«Power: ≤30W
Feature
vPhase shift spectroscopy detection, high sensitivityvRegardless of the light intensity fluctuations, the light source is inexpensive and easy to control.vDirect measurement of atmospheric aerosol extinction coefficient and visibility in laboratory and field vNo calibration, low maintenance costs
ApplicationApply to haze climate impact studies, aerosol radiative forcing research, laboratory studies of aerosol optical
properties, environmental monitoring, meteorology, satellite remote sensing test.
Model Name EQMS-3000 Environmental Quality Monitoring Sytem
Classification Environmental Monitoring
Description
According to the status and characteristics of construction sites and production industry generated pollution, with more sophisticated network cloud platform technology, the company developed the digital EQMS-3000 remote monitoring and management system. The system can measure the air concentration of particulate matter (including: TSP, PM10, PM2.5), surrounding noise, and five meteorological parameters and other indicators online, process the monitoring data, and then upload the monitoring results to the server via GPRS / network, to realize multi-mode intelligent management of online monitoring and analysis and forecast.
Specification
«Noise Range: 30dB ~ 130dB (A)
«Noise Frequency: 20Hz ~ 12.5kHz
«Noise Error: ± 0.5dB3 3
«Particles Range: 0.01mg/m ~10mg/m3
«Particles Resolution: 0.001mg / m
«Winds Range: 0 ~ 45m/s
«Winds Accuracy: ± 0.3m/s
«Humidity Range: 0 ~ 100% RH
«Temperature Range: -50℃~ + 100℃
«Camera Resolution: 1280 × 960
«Camera Enclosure Rating: IP65
«Camera Angle: 360 ° without dead angle
«Output Interface: RS485 / Ethernet, 3G optional
«Working Temperature: -20℃~ + 50℃
Featurev
v
Supporting map accurate navigation and positioning, remote video surveillance
Automatic alarm to remind which is contributing to on-site staff issued a timely warning, pay attention to the
prevention and control
22 en.zetian-tech.com
Environmental Monitoring
Model Name DPM-6000 PM2.5/PM10 Particulate Monitoring System
Classification Environmental Monitoring
Description
DPM-6000 uses the beta decay method to measure the concentration of PM10 and PM2.5 in the air.Analyzer
can automatically monitor PM10 by PM10 sampling head,equip with PM2.5 sampling port to automatically
monitor smaller particle material, and can be set up to monitor the total suspended particles (TSP). Equipment
can be either fixed online use or as a portable devices onboard use.
Specification
«Method: the beta decay method
«Monitoring objects: PM10 / PM2.53
«Range: 0 ~ 5 mg/m3
«Detection limit: 10μg/m
«Linearity: correlation coefficient > 0.99
«Sampling Flow: 16.7 L/min
«Sampling Time: 5mins~1000 mins can be set
«Flow Error: ≤±1% F.S.
«Membrane Filter Replacement: 3 months
«Working Temperature: 0 ~ 40 ℃
Feature
vCalibration in advance, automatic zero calibration, automatic fault diagnosis function, greatly reduce the maintenance work requiredvCan choose PM10 and PM2.5 cutter to realize the monitoring of different diameter particlesvA variety of transport ways such as RS232/485, USB, GPRS, Ethernet, achieve real-time remote monitoring and data transmissionvThe built-in LCD touch control, convenient to operate at the scene of mobile platforms such as the on-board monitoring stationvLess than 100 Ci of sealed radiation sources, do not need to worry about radiation safety
Application Apply to environmental air quality monitoring place such as industrial pollution area, residential area, city, etc.
Model Name PMMS-5000 Atmospheric Heavy Metals Analyzer
Classification Environmental Monitoring
Description
According to US EPA IO - 3.3 standard method of heavy metals, PMMS – 5000 uses XRF nondestructive testing technology and atmospheric automatic enrichment technology to realize the accurate measurementof atmosphere heavy metals such as lead, mercury, cadmium, chromium, arsenic, etc. It is widely used in environmental air quality monitoring place such as industrial pollution area, residential area, city, etc.
Specification
«Method: X-ray fluorescence
«The main monitoring elements: 28 kinds of elements: lead, cadmium, mercury, arsenic, chromium, copper, zinc, nickel, vanadium, iron, silver, selenium, bromine, tellurium, antimony, tin, titanium, cobalt, manganese, p a l l a d i u m , t h a l l i u m , s c a n d i u m , molybdenum, vanadium, Ca, Cesium potassium, gallium
3«Measuring Range: 0 ~ 140 g/m
3«Detection Limit: can reach ng/m order of magnitude
«Linearityity: correlation coefficient < 0.99
«Sampling Velocity: (4 ~ 16.7) L/min (adjustable)
«Membrane Filter Replacement Cycle: 3 months
«S a m p l i n g a n d A n a l y s i s Ti m e : ( 1 0 ~ 3 0 0 ) m i n (programmable)
Feature
vCan measure heavy metal elements up to 28 kinds, measuring element can be extended, detection limit 3reached ng/m
vCalibration in advance, automatic zero calibration, automatic fault diagnosis function, greatly reduce the maintenance work required
vCan choose TSP,PM10 , PM2.5 cutter to realize the monitoring of different diameter particlesvUsing low energy X-ray source, do not worry about any radiationvA variety of transport ways such as RS232/485, USB, GPRS, Ethernet, achieve re-al-time remote
monitoring and data transmission
ApplicationApply to air quality monitoring, analysis of characteristics of air particulates, atmospheric background survey, environmental assessment, licensing, pollution source location, resource, pollution forecast warning, etc.
FeaturevAutomatic Alarming reminds on-site workers
vSmart contrast providing project and regional dynamic analysis
vJoint prevention and control, open-sharing platform
ApplicationApply to dust and noise online monitoring in construction sites, roads, residential, factory sector, tourism, waste incineration plants and other construction sites and production situations.
Model Name AEM-2000 NO Analyzer2
Classification Environmental Monitoring
Description
It is a self-developed analysis extinction analyzer product for domestic and overseas environmental online
monitoring. The analyzer is based on phase-shift spectral technology, can be used to measure NO 2
concentration of ppb ~ppm level directly. The analyzer is one of the analyzer for ambient air quality monitoring
system, is used for real-time online of environmental quality assessment.
Specification
«Method: Phase Shift Spectroscopy
«Range: 0 ~ 1ppm
«Detection Limit: 0.1ppb
«Sample Flow: <1L/min
«Light Source: LED
«Digital Communications: RS485 / RS232 / GPRS
«Working Temperature: -5℃~ + 45 ℃
«Humidity: 0 ~ 100% RH
23 en.zetian-tech.com
Environmental Monitoring
Feature
vPhase shift spectroscopy detection, high sensitivityvRegardless of the light intensity fluctuations, the light source is inexpensive and easy to control.vDirect measurement of NO2
vThe operation is simple, the system response is fast
Application Climate impact study, atmospheric environmental monitoring field
Model Name AM-5100 SO Analyzer2
Classification Environmental Monitoring
Description
SO analyzer adopts ultraviolet fluorescence method and combines with advanced microprocessor 2
technology. It provides accurate and reliable detection of SO at ppb~ppm level which meets the 2
requirements of ambient gas monitoring and online monitoring of pollution source with dilution method.
The operation principle is based on ultraviolet fluorescence method. After absorbing the ultraviolet energyg,
SO molecule is inspired to excited state and once it returns to ground state, it will release specific 2
fluorescence. The intensity of fluorescence could realize quantitative measurement. Measurement stability
is greatly improved by using timed dark current measurement to compensate photomultiplier drift and
reference detector to calibrate the change of UV light intensity. With high-efficiency hydrocarbon remover
and unique optical design the analyzer can effectively clear up inexactitude caused by interference.
This analyzer can completely control all functions and also provides online instruction for important work
parameters. Real time auto compensation for temperature and pressure will be made during measurement.
Specification
«Range: 0 ~ 500ppb
«Zero Noise: ≤0.2ppb
«Lower Detection Limit: ≤0.4ppb
«Indication Limit: ±1%F.S.
«Zero Drift: ±1ppb/d
«Span Drift: ±1%F.S.
«Response Time: ≤120s
«MTBF: ≥7d
«Environment Temperature: 5℃ ~ 40℃
«Environment humidity: 0~95%RH
«Weight: 15kg
«Size: 178mm×432mm×600mm
«Power Supply: 200V~240V,50/6Hz, 300W
«Ports: Analog, Dihital, RS232, RS485, RJ45, USB
«Communication Protocol: Modbus
Feature
v
v
v
v
v
Multiple functional operations by microprocessor
Continuous self-checking with alarm function and self-check of light intensity attenuation
Response time optimized by signal filter technology of self-adaptation
Compensation function for temperature and pressure
Colorful display and screen touch operation, large memory and history data saved automatically
Application Atmosphere monitoring and dilution of pollution sources on-line monitoring
Model Name AM-5200 NOx Analyzer
Classification Environmental Monitoring
Description
NOx analyzer adopts chemiluminescence method and combines with advanced microprocessor technology.
It provides accurate and reliable detection of NOx at ppb~ppm level which meets the requirements of
ambient gas monitoring and online monitoring of pollution source with dilution method.
The operation principle is based on chemiluminescence method. After absorbing the chemical energy and
the reacting with O , NO is inspired to excited state and once it returns to ground state, it will release energy 3
in form of light quantum. The intensity of light emission is directly proportional to gas concentration, which
could realize quantitative measurement.
This analyzer can completely control all functions and also provides online instruction for important work
parameters. Real time auto compensation for temperature and pressure will be made during measurement.
Specification
«Range: 0 ~ 500ppb
«Zero Noise: ≤0.2ppb
«Lower Detection Limit: ≤0.4ppb
«Indication Limit: ±1%F.S.
«Zero Drift: ±2ppb/d
«Span Drift: ±1%F.S.
«Response Time: ≤90
«MTBF: ≥7d
«Environment Temperature: 5℃ ~ 40℃
«Environment Humidity: 0~95%RH
«Weight: 15kg
«Size: 178mm×432mm×600mm
«Power Supply: 200V~240V, 50/6Hz, 300W
«Ports: Analog, Dihital, RS232, RS485, RJ45, USB
«Communication Protocol: Modbus
Feature
vNO, NO , NOx is measured separately, .2
vContinuous self-checking with alarm function, permeation drying tube equipped with ozone generator.
vResponse time optimized by signal filter technology of self-adaption.
v
v .
multiple functional operations by microprocessor
Compensation function for temperature and pressure.
Colorful display and screen touch operation, large memory and history data saved automatically
Application Atmosphere monitoring and dilution of pollution sources on-line monitoring
24 en.zetian-tech.com
Environmental Monitoring
Model Name AM-5300 CO Analyzer
Classification Environmental Monitoring
Description
CO analyzer adopts non-dispersive infrared spectrum and combines with advanced microprocessor
technology. It provides accurate and reliable detection of CO at ppm level to meet the requirement of
ambient gas monitoring.
The principle is non-dispersive infrared based on gas filter correlation technology. CO molecule absorbs
specific infrared light which is consistent with Beer-Lambert principle. CO concentration can be obtained by
comparing infrared energy adsorption by sampling gas and reference gas.
This analyzer can completely control all functions and also provides online instruction for important work
parameters. Real time auto compensation for temperature and pressure will be made during measurement.
Specification
«Range: 0 ~ 50ppm
«Zero Noise: ≤0.2ppb
«Lower Detection Limit: ≤0.04ppb
«Span Noise≤0.025ppb
«Indication Limit: ±1%F.S.
«Zero Drift: ±0.2ppm/d
«Span Drift: ±1%F.S.
«Response Time: ≤60s
«MTBF: ≥7d
«Environment Temperature: 5℃ ~ 40℃
«Environment humidity: 0~95%RH
«Weight: 15kg
«Size: 178mm×432mm×600mm
«Power Supply: 200V~240V, 50/6Hz, 200W
«Ports: Analog, Dihital, RS232, RS485, RJ45, USB
«Communication Protocol: Modbus
Feature
vMultiple functional operations by microprocessor
vContinuous self-checking with alarm function and self-check of light intensity attenuation
vResponse time optimized by signal filter technology of self-adaptation
vCompensation function for temperature and pressure
vColorful display and screen touch operation, large memory and history data saved automatically
Application Atmosphere monitoring
Model Name AM-5400 Ozone Analyzer
Classification Environmental Monitoring
Description
Ozone analyzer adopts ultraviolet spectrometry principle and combines with advanced microprocessor
technology. It provides accurate and reliable detection of O at ppb~ppm level to meet the requirement of 3
ambient gas monitoring.UV adsorption Ozone analyzer is developed based on Beer-Lambert technology. It
is applied to monitor low concentration O in ambient air.3
This analyzer can completely control all functions and also provides online instruction for important work
parameters. Real time auto compensation for temperature and pressure will be made during measurement.
Specification
«Range: 0 ~ 500ppb
«Zero Noise: ≤0.5ppb
«Lower Detection Limit: ≤1ppb
«Span Noise: ≤2.5ppb
«Indication Limit: ±2%F.S.
«Zero Drift: ±1ppb/d
«Span Drift: ±1%F.S.
«Response Time: ≤60s
«MTBF: ≥7d
«Environment Temperature: 5℃ ~ 40℃
«Environment Humidity: 0~95%RH
«Weight: 15kg
«Size: 178mm×432mm×600mm
«Power Supply: 200V~240V, 50/6Hz, 300W
«Ports: Analog, Dihital, RS232, RS485, RJ45, USB
«Communication Protocol: Modbus
Feature
vMultiple functional operations by microprocessor
vContinuous self-checking with alarm function and self-check of light intensity attenuation
vResponse time optimized by signal filter technology of self-adaptation
vCompensation function for temperature and pressure
vColorful display and screen touch operation, large memory and history data saved automatically
Application Atmosphere monitoring
Model Name AM-5800 Dynamic Dilution Calibrator
Classification Environmental Monitoring
Description
Based on microprocessor technology, Dynamic Dilution Calibrator is developed for precise gas analyzer and
supports multi paths calibration. With high-accuracy mass flow controller and standard gas, this system can
provide calibration gas for zero point and span inspection of multiple gas components. Up to 4 gas sources
can be provided.
Built-in programmable ozone generator is optionally equipped with dynamic dilution calibrator. It can be
used to calibrate O accurately and reliably. Also It can be used in GPT to produce NO . Linear drive of 3 2
multi-point section is adopted for ozone generator to ensure the repeatability and accuracy of O 3
concentration; optional photometer can improve high-level of accuracy control for ozone generator.
Instrument design emphases fast response, high repeatability, high accuracy and ease of operation. Working
with ozone generator, quality control of lab and gas analyzer can be ensured.
25 en.zetian-tech.com
Environmental Monitoring
Specification
«
«
«
«Linearity: 0 5
« 0 2
«
«
Flow Range of Diluent Gas:
(0~5~10~20)SLPM(operation)
Flow Range of Standard Gas:
(0~5~10~20)sccm(operation)
Accuracy of Flow Control: ±1%F.S.
± . %F.S.
Repeatability of Flow Control: ± . %F.S.
Requirement of Zero Gas: 10SLPM@30psi
Standard Gas Inlet: 4
«Diluent Gas Inlet
Response Time: T <60s90
Environment Temperature: 5℃ ℃
: 1
«
« ~40
«Environment Humidity: 0~95%RH
«Weight: <15kg
«Size: 178mm×432mm×600mm
«Power Supply: 200V~240V, 50/6Hz, 200W
«Ports: Analog, Dihital, RS232, RS485, RJ45, USB
«Communication Protocol: Modbus
Feature
vContinuous self-checking with alarm function
vHigh precise mass flow controller, large dilution ratio and fast response
vQuartz GPT chamber, multi interfaces for calibration gas
vOzone generator and ozone photometer are optional
vColorful display and screen touch operation, large memory and history data saved automatically
vTask software is allowed to monitor test data during operation
Application Atmosphere monitoring
Model Name AM-5900 Zero Gas Generation
Classification Environmental Monitoring
Description
The zero gas generator provides clean and dry zero-level air. It is mainly applied to zero calibration of
ambient air quality monitoring system or analyzer. It can also be used as flushing gas in permeation tube &
furnace and oxidant gas for FID analyzer.
Zero gas generator includes external oil-free air compressor, pressure and flow controller, water removal
system. Based on adsorption, filter, reaction and other principles, the removers can remove SO , NO, NO , 2 2
O , H S, CO, NH , hydrocarbon, particulate matter and output dry and clean air as well.3 2 3
The water removal system inside the analyzer could remove the moisture in the air. The dew point of
produced air is lower than -20℃ and it is not effected by the inlet dew point. It contributes to removal of
other gases as well as greatly extending servicelife of other chemical removal.
Specification
«Output concentration:
SO <0.5ppb2
NO <0.5ppb
NO <0.5ppb2
O <0.5ppb3
CO <0.01ppb
CH <5ppb4
Non-methane hydrocarbon <0.02ppm
«
«
«
«Weight: 14kg
«Size: 53.5mm×42.5mm×17.5mm
«Power Supply: 200V~240V, 50/6Hz, 300W
Output: 20 SLPM@30 psi
Dew Point: -20℃ reach 15LPM; -10℃ reach
15LPM+
Pump: External, oil-free, long service life
Feature
v
v
v
v
vColorful display and screen touch operation, large memory and history data saved automatically
v
Strong ability to remove water by adopting three-class water removal system with auto dehydration
Equipped with long-lasting SO , NO, NO , and H S remover, and equipped with high-efficiency CO and 2 2 2
hydrocarbon remover
Generated clean and dry zero gas with stable flow and pressure, up to 20L/min zero gas flow, output pressure
adjustable
Easy operation, less routine maintenance
External air compressor has automatic drainage function under unattended condition
ApplicationApply to ambient air quality monitoring system and instrument zero calibration, it can also be used as a gas
flushing of penetration tube furnace or equipped with FID analyzer as combustion-supporting gas
26 en.zetian-tech.com
Environmental Monitoring
Fiber
Filter
ElectrovanneFluoro tube
Sampling Pole Joint
Based on years of experience in the practical application of environmental and industrial sectors, we
have established a rich category, adequate supply of spare parts inventory, and developped a
comprehensive spare parts management system. As long as customers make spare parts needs, we will
arrange spare parts management personnel to verify the spare parts requirements at , and
provide preferential price of spare parts and technical services.
the first time
Note: Please contact us for details.
PT100
Graphite GasketO-ring
Quartz tube digestionPeristaltic pump hose
Spare Parts
27
Metering Tube
en.zetian-tech.com
If you want to know more details, please visit: http://en.zetian-tech.com
HANGZHOU ZETIAN TECHNOLOGY CO.,LTD.
Phone 86-13588711905
86-571-28322780
Fax 86-571-87851772
Email [email protected]
Website en.zetian-tech.com
Add Taiheng Mansion, 22 Zhiren Street, Binjiang District, Hangzhou, Zhejiang Province, China.
:
:
:
:
: