industrial meters for the uk gas industry - · pdf filerange is en12405 - compliant and will...

4
Industrial Meters Three technologies to meet gas measurement needs Flowrates from16 m³/hour to 6500m³/hour All meters OFGEM approved All meters ATEX certified RPD & Turbine meters PED certified Model and Serial numbers to UK requirements Designed for long term accuracy and reliability Actaris manufacture an extensive range of industrial gas meters in their factories in the UK and Germany. The range encompasses Diaphragm, RPD and Turbine technologies. Actaris’ extensive experience and breadth of technology allows users to select the most suitable meter for a specific task, secure in the knowledge that they are selecting from meters whose performance is second to none. The site at Stretford, Manchester, has been famous for the manufacture of high quality diaphragm meters for many years, and the “U” series meters are highly regarded technically around the world. Karlsruhe has equal fame for it’s “Rombach” Diaphragm and Turbine meters, and is fast growing a strong reputation for developing the Delta RPD meters into a globally recognised range. Please contact Actaris Manchester for full product information to cover the meters reviewed in this document. Diaphragm Meters “Delta” RPD Meters “Fluxi” 2000 TZ Turbine Meters The “U” Series of diaphragm meters cover flow rates from 0.04m /h to 160m /h. Diaphragm meter technology gives long life, accuracy and the ability to register very small gas flows. The Delta range of RPD meters can register flow rates from 0.5m /h to 1000m /h. Compact design with flexible measurement performance over a wide range of loads make these a popular “general purpose” meter. The Fluxi turbine meters are a low cost high accuracy range and can be used in specific installations for metering up to 6500m /h of gas. These are primarily used for applications where flow is constant or varying within a range down to 1/20 of the maximum flow rate. ³ ³ ³ ³ ³ For the UK Gas Industry

Upload: hoangkhuong

Post on 30-Jan-2018

232 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Industrial Meters For the UK Gas Industry - · PDF filerange is EN12405 - compliant and will operate with all LF-equipped meters. The combination of reliable pulse collection technology,

Industrial Meters

4

4

4

4

4

4

4

Three technologies to meet gasmeasurement needs

Flowrates from16 m³/hour to6500m³/hour

All meters OFGEM approved

All meters ATEX certified

RPD & Turbine meters PED certified

Model and Serial numbers to UKrequirements

Designed for long term accuracy andreliability

Actaris manufacture an extensive range of

industrial gas meters in their factories in the

UK and Germany. The range encompasses

Diaphragm, RPD and Turbine technologies.

Actaris’ extensive experience and breadth of

technology allows users to select the most

suitable meter for a specific task, secure in

the knowledge that they are selecting from

meters whose performance is second to

none.

The site at Stretford, Manchester, has been

famous for the manufacture of high quality

diaphragm meters for many years, and the

“U” series meters are highly regarded

technically around the world.

Karlsruhe has equal fame for it’s “Rombach”

Diaphragm and Turbine meters, and is fast

growing a strong reputation for developing

the Delta RPD meters into a globally

recognised range.

Please contact Actaris Manchester for full

product information to cover the meters

reviewed in this document.

Diaphragm Meters

“Delta” RPD Meters

“Fluxi” 2000 TZ Turbine Meters

The “U” Series of diaphragm meters cover

flow rates from 0.04m /h to 160m /h.

Diaphragm meter technology gives long life,

accuracy and the ability to register very small

gas flows.

The Delta range of RPD meters can register

flow rates from 0.5m /h to 1000m /h.

Compact design with flexible measurement

performance over a wide range of loads

make these a popular “general purpose”

meter.

The Fluxi turbine meters are a low cost high

accuracy range and can be used in specific

installations for metering up to 6500m /h of

gas. These are primarily used for

applications where flow is constant or varying

within a range down to 1/20 of the

maximum flow rate.

³ ³

³ ³

³

For the UK Gas Industry

Page 2: Industrial Meters For the UK Gas Industry - · PDF filerange is EN12405 - compliant and will operate with all LF-equipped meters. The combination of reliable pulse collection technology,

Meter Capacity Depth Width Height Connection Connection Connection Working Pressure Cyclic WeightModel m³/h mm mm mm Size separation Distance Pressure Absorbtion Volume kg

mm mm mbar mbar lU6 6 197 230 270 1”Male 152.4 85 75 1.22 2 3.5

BS746SC6 6 170 240 302 3/4” /1” - - 50 1.3 2 4.0

BS21MDA16 16 346 343 283 11/4”Male 152.4 160 75 1.22 4 9.5

BS746MDA25 25 308 406 415 2”Male 250 135 75 1.62 10 16.4

BS746MDA40 40 381 553 496 2” Male 240 178 75 1.22 20 28.0

BS746MDA65 65 385 614 545 65mm PN10 335 178 75 2.36 25 41.8

MDA100 100 552 775 630 80mm PN10 430 271 75 1.32 50 70.0MDA160 160 552 775 660 100mm PN10 430 271 75 2.91 71.4 75.0

Diaphragm MetersThe “U” Series of diaphragm meters cover flow

rates from 0.04m³/h to160m³/h. Diaphragm

meter technology gives long life, accuracy and

the ability to register very small gas flows. The

high performance of the modern Diaphragm

meter is due to a combination of the use of

proven materials technology, a stable design,

and diligence in manufacturing.

Fixed stroke measurement units lead to

enhanced measurement stability and accuracy.

This allows all calibration to be performed in

the index.

Modern materials and the latest moulding and

machining techniques mean that there is no

Fixed stroke measuring units

Life lubricated bearings

requirement for lubrication during the meters

normal operating life. In fact, there is no

routine maintenance requirement for the U

series meters.

A strong partnership with our suppliers means

that Diaphragms are manufactured to a

specification unique to UK requirements.

These diaphragms are designed to operate for

extended periods while exposed to the worst

that the gas network can deliver.

Radial valves constructed from low friction

materials give the U series exceptional low flow

accuracy, and deliver low pressure drop across

the whole flow range.

Synthetic Diaphragms

Radial Valve Design

4

4

4

4

4

4

4

4

Range covers commercial andindustrial applications

Flow rates up to160 m³/hour

Manufactured to suit UK Industryrequirements

All models OFGEM Approved

Exceptionally low pressureabsorbtion

Safely designed to BS4161

Comply with EN1359

Manufactured in anISO9001/ISO14001 Environment

D

CD

W

H

CS

Page 3: Industrial Meters For the UK Gas Industry - · PDF filerange is EN12405 - compliant and will operate with all LF-equipped meters. The combination of reliable pulse collection technology,

Meter Capacity a b c d e f DN Weight Pressure dP* Number Index Pulse Max.Model m³/h mm mm mm mm mm mm mm kg Pmax @ Qmax of Resolves Value Turndown

Bar mbar Dials m³ m³MRA25A 25 66 91 157 96 96 121 40 2 12 0.83 9 0.001 0.01 50MRA40A 40 86 101 187 96 96 121 40 3 12 1.38 9 0.001 0.01 50MRA65B 65 118 213 331 182 91 171 50 11 16 0.88 9 0.01 0.1 160

MRA100B 100 118 213 331 182 91 171 50 11 16 1.08 9 0.01 0.1 160MRA160C 160 150 251 403 182 87 171 80 15 16 1.73 9 0.01 0.1 160MRA200C 200 180 275 455 182 87 171 80 18 16 3.15 9 0.01 0.1 160MRA250C 250 181 255 436 192 121 241 80 19 16 2.73 9 0.1 1 200MRA300D 300 218 290 510 239 121 241 100 22 16 a.aa 9 0.1 1 160MRA400D 400 284 358 642 239 121 241 100 26 16 2.83 9 0.1 1 200

MRA650E 650 375 265 640 306 153 450 150 102 12 2.63 8 0.1 1 50MRA1000E 1000 451 353 760 495 300 500 150 200 12 4.01 8 0.1 1 50

MRA450D 450 284 358 642 239 121 241 100 26 16 3.01 9 0.1 1 20

ABC

DE

F

MRA25A, MRA40A

C

E

F

D

B A

Other Sizes

RPD Meters

The Delta range of RPD meters can register

flow rates from 0.5m³/h to1000m³/h. The

compact design and flexible measurement

performance over a wide range of load types

makes these a popular “general purpose”

meter. Meters are factory set for up, down,

left-to right or right-to-left flow direction, and

must be installed horizontally. Delta meters are

relatively insensitive to flow conditions, and can

be installed in small spaces with bends and

other features nearby in the pipework. The

use of a flexible connector is recommended in

installations with low metering pressure.

The MRA25A and MRA40A are the metric

successors to the recognised D0.8 and D1.5

meters. The Series 0 meters feature BS21

Series 0

DN40 screw connections which help to

facilitate low cost installation.

The models from 2” to 4” ( MRA100B to

MRA400D) share many components to

reduce cost and maximise flexibility. With

extruded aluminium bodies, an index with two

field-replaceable LF switches, and turndown

ratios of up to 200:1, these meters reduce any

unregistered gas and offer good network

performance and low maintenance costs.

Series 3 meters are the largest of the Delta

range. Tthe MRA650E and MRA1000E, being

metric equivalents of the D23 and D35 meter

offer a rugged approach to industrial metering.

Series1/ 2

Series 3

*Pressure drop with a gas density of 0.83 kg/m at 0°C and1013 mbar³

Page 4: Industrial Meters For the UK Gas Industry - · PDF filerange is EN12405 - compliant and will operate with all LF-equipped meters. The combination of reliable pulse collection technology,

UK-

00

003

.0-G

B-0

3.04

© C

opyr

ight

20

04, A

ctar

is U

K L

imite

d. A

ll rig

hts

rese

rved

. Act

aris

rese

rves

the

right

to c

hang

e th

ese

spec

ifica

tions

with

out p

rior n

otic

e.

Turbine Meters

Meter Capacity length Index Pipe Weight dp** Index LF Pulse Nom HF3Model m³/h mm height Size kg @ Qmax Resolves Value @ Qmax

mm mm mbar m³ m³ HzMTA160C 160 240 175 80 19 2.4 0.1 1 1182MTA250C 250 240 175 80 19 5.9 0.1 1 1847MTA400C 400 240 175 80 19 12.8 0.1 1 1700MTA250D 250 300 190 100 22 2.2 0.1 1 1118MTA400D 400 300 190 100 22 5.4 0.1 1 1789MTA650D 650 300 190 100 22 11.8 0.1 1 1673MTA650E 650 450* 200 150 54 2.7 0.1 1 1185

MTA1000E 1000 450* 200 150 54 6.6 0.1 1 1823MTA1600E 1600 450* 200 150 54 13.8 0.1 1 1678MTA1000F 1000 600* 235 200 83 1.6 1 10 777MTA1600F 1600 600* 235 200 83 4.0 1 10 1244MTA2500F 2500 600* 235 200 83 8.7 1 10 1071MTA1600G 1600 750* 265 250 120 2.1 1 10 775MTA2500G 2500 750* 265 250 120 5.0 1 10 1212MTA4000G 4000 750* 265 250 120 11.0 1 10 1115MTA2500H 2500 900 295 300 190 2.0 1 10 807MTA4000H 4000 900 295 300 190 5.0 1 10 1291MTA6500H 6500 900 295 300 190 9.5 1 10 1156MTA4000J 4000 1200 345 400 440 1.8 1 10 541MTA6500J 6500 1200 345 400 440 4.4 1 10 879

The CORUS-PTZ Volume converter

range is EN12405 - compliant and will

operate with all LF-equipped meters.

The combination of reliable pulse

collection technology, PT1000

temperature sensing, precision pressure

sensors, and a 5 year battery life make

the Corus an accurate, reliable, cost-

effective solution for volume conversion

in both PT and PTZ applications.

The converter can provide pulse outputs

for use in external dataloggers, RS232

communications to modems, and 4-20

mA flow rate calculated from the LF

pulse rate.

No software is required to commission

the converter. All synchronisation and

pulse weight settings can be carried out

from the front panel, removing the need

for software and laptops for

commissioning.

*These meters are also available with “short” bodies: the DN150 (”E”) with 335 mm length,DN200 and 250 (”F” & “G”) with 400 mm length

**Pressure drop with a gas density of 0.83 kg/m at 0°C and1013 mbar³

“Fluxi 2000 TZ” Turbine MetersThe Fluxi range of turbine meters may be used

in specific installations for metering up to

6500m³/h of gas. These are used for

applications where flow is constant or varying

within a range down to1/20 of the maximum

flow rate.

Turbine meters are inferential meters. During

ioperation the flow of gas turns a turbine wheel

and the speed of rotation is proportional to the

linear speed of the gas. The motion of the

wheel is transmitted to the index via a

magnetic coupling.

A Fluxi 2000TZ turbine meter consists of 5

main components:

Main Body containing the flow and turbine

components

Flow straightener to accelerate and

stabilise the gas flow

Measuring unit including Turbine Wheel

Magnetic coupling to transfer the motion

of the turbine wheel

Index to register the volume of Gas.

4

4

4

4

4

Volume Converter

Common characteristics

Flange: PN16 Standard, others on request

Pressure:12 Bar standard, up to100 Bar

on request

Material: GGG40 Cast Iron standard, Steel

on request

HF Up to 2 HF3 may be fitted on request

LF 2 internal LF fitted as standard. An

additional LF may be retrofitted

”Short Body” available for F35, F56, F88

and F140/10” replacement

4

4

4

4

4

4

Actaris UK Limited Gas Division

P.O.Box 3 Talbot Rd, Stretford

MANCHESTER M32 0XX, UK

www.actaris.com

Tel

Fax

0161 865 1181

0161 864 3379