Raise Energy Solutions, LLC, 1059 Triad Court, Suite 1, Marietta, Georgia 30062 USA www.RaiseEnergySolutions.com | 678.331.5548 | [email protected] Energy and Water Savings 10%+ Energy Savings 20% Water Savings Fully Automated Skid-Mount - Particle Precipitator Water - Filtration System Full Service Control of - Total Dissolved Solids - Total Suspended Solids - Conductivity Typical Applications Chillers / Cooling Towers Boilers Plate & Frame Exchangers Tube Bundle Heat Exchangers Reverse Osmosis Humidifiers Air Compressors Fountains Industrial-Commercial HVAC Water Filtration System Removes suspended solids down to one micron in Cooling Tower, Chiller, and Boiler Systems to reduce energy and save water.

Upload: votu

Post on 30-Mar-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Raise Energy Solutions, LLC, 1059 Triad Court, Suite 1, Marietta, Georgia 30062 USA www.RaiseEnergySolutions.com | 678.331.5548 | [email protected]

Energy and Water Savings

• 10%+ Energy Savings• 20% Water Savings• Fully Automated Skid-Mount

- Particle Precipitator Water - Filtration System

• Full Service• Control of

- Total Dissolved Solids - Total Suspended Solids - Conductivity

Typical Applications

• Chillers / Cooling Towers• Boilers• Plate & Frame Exchangers• Tube Bundle Heat Exchangers• Reverse Osmosis• Humidifiers• Air Compressors• Fountains

Industrial-Commercial HVAC Water Filtration System

Removes suspended solids down to one micron inCooling Tower, Chiller, and Boiler Systems to reduce energy and save water.

RECLEAN PRO™ 1

RECLEAN PRO™ Approach to Water and Energy Savings

RECLEAN PRO’s™ Water/Energy Savings ApproachTo provide a healthy, clean condenser/evaporative system is our primary goal A clean heat exchanger will save water and energy, as well as extend equipment lifecycles.

RECLEAN PRO™ Concentrates on Total Suspended Solids Removal and Control of Total Dissolved SolidsOur technology improves thermal transfer in the condenser and evaporative heat exchangers. This will utilize each chiller to its optimal efficiency thereby saving energy. In turn, the cooling towers are a slave to the chiller heat load and abilities to transfer temperature through their exchangers. This is where water savings are achieved.

By removing suspended solids and controlling dissolved solids RECLEAN PRO™ has been successful in reducing large percentages of make-up water to the cooling towers and energy needed to operate chillers. Unlike most side-stream filters RECLEAN PRO’s™ system uses no media and requires no backwash or continuous maintenance.

RECLEAN PRO’s™ philosophy is to concentrate on evaporation rates rather than trying to extend bleed cycles. Make-up water to your cooling towers is divided into evaporation (75%) and bleed (25%). Bleed cycles are a necessary evil to rid the system of dissolved minerals (scale). Pushing or extending bleed cycles is risky business and will cost energy in the long run. Remember, bleed makes up only 25% of a towers usage in most cases.

RECLEAN PRO™ removes 95% of suspended solids down to one micron, which greatly increases the condenser water’s thermal transfer rate, and also manages dissolved solids that may produce fouling (scale). RECLEAN PRO™ monitors chillers approach temperatures which will verify our system’s effectiveness in keeping exchanger tubes clean. RECLEAN PRO™ monitors and logs monthly make-up and bleed usages.

RECLEAN PRO™ concentrates on evaporation rate needed – 75% of your system’s usage.RECLEAN PRO’s™ water savings have never been the result of increased bleed cycles. Our success is in direct proportion to the improvement in equipment efficiencies. RECLEAN PRO™ has been servicing Fortune 500 companies since 1997.ROI is between two and three years.Typical installation – 10-15% energy savings 20+% make-up water savings

Our system is a central treatment skid with PLC that requires a simple installation (2-3 days).

Condenser Loop Evap Loop One PVC Inlet One PVC Inlet One PVC Outlet One PVC Outlet One PVC Drain One PVC Drain One 20A Circuit One 20A Circuit

Pipe sizes will vary with tonnage capacity

RECLEAN PRO™ can work with existing chemical suppliers to enhance your chemical program.

RECLEAN PRO™ 2

• Hospitality• High Rise Residential Condos• State & Federal Government• Casinos & Convention Centers

FOULING : Removal of Total Suspended Solids (TSS)( Dirt I Pollen I Airborne Particles )

• A 1000-ton tower will collect over 3000 pounds of solids in one year. 200-tons - over 600 pounds per year

• Particles over 20 microns cannot stay in solution and will settle out in tower basins and quiet areas throughout the condenser loop.

• Particles from one to ten microns tend to stay in solution and foul the entire condenser loop. These particles make up the majority of suspended particle count in an open condenser loop (see Particle Analysis reports).

• High particle counts decrease thermal transfer rates costing energy water and equipment life cycles. Side-stream filters have been used to remove these solids from open loops: standards- sand centrifugal- separators- do not remove microns smaller than 10 and are high maintenance.

• RECLEAN PRO™ utilizes a patent pending particle precipitator that is a side-stream installation. RECLEAN PRO™ uses no media to remove suspended particles and requires no backwash or maintenance of typical sand filters. Our technology utilizes a combination of low DC voltage and magnetic electrodes to coalesce and parcipitate suspended particles down to the sub-micron level.

• RECLEAN PRO™ will remove 95% of all TSS down to one micron.

• RECLEAN PRO’s™ treatment skid is a fast inexpensive installation. Our system is designed for a 15+ year life-cycle.

• RECLEAN PRO’s™ treatment skid program for control of TSS will save 10-15% in efficiency levels of the chill/tower operation year-after-year.

THERMOTRANSFER

LOW EFFICIENCY

TSSFOULING

ENERGY& WATER

USE

OPERATIONS

HIGH EFFICIENCY

THERMOTRANSFER

CLEAN UPTSS

ENERGY& WATER

COST

SAVINGS

TOTAL SUSPENDED SOLIDSTSS - Dirt - Pollen - Airborne Particles

Chiller Condenser Open Loop

REMOVE TSS BY 95% DOWN TO 1 MICRON

WITH

= 10-15%Energy andWater Savings

RECLEAN PRO™ 3

FOULING : Removal of Total Dissolved Solids (TDS) (Scale)

• As a cooling tower evaporates condenser water mineral salts are left behind (TDS). These minerals concentrate and are discharged from the open loop by means of a conductivity meter and bleed valve.

• Make-up water is piped to the cooling towers to replace evaporation (75%) and bleed (25%) water loss.

• These minerals form scale on heat transfer surfaces, decreasing thermo transfer and costing energy, water and equipment life-cycles.

• Scale forms in the laminar boundary layers where water, heat and pipe surface meet.

• Moving water and stationary pipe produce frictional laminar boundary layers - dead space between water and pipe. This is where scale and corrosion usually take place.

• Laminar boundaries affect thermo transfer. Scale affects thermo transfer and the system’s ability to discharge heat.

• When an electrostatic charge is introduced to a moving fluid, laminar boundaries collapse. Scale that formed in the dead space (laminar boundary) is now subjected to shear force and is removed.

• When laminar boundary layers are decreased, thermo transfer increases and energy and water efficiencies are increased.

• RECLEAN PRO’s™ patented high voltage electrode prevents scale from forming and, if present, removes it.

• RECLEAN PRO’s™ treatment skid program for the control of TDS will save 10-15% in efficiency levels of the chiller/tower operation.

THERMOTRANSFER

LOW EFFICIENCY

TSSFOULING

ENERGY& WATER

USE

OPERATIONS

HIGH EFFICIENCY

THERMOTRANSFER

CLEAN UPTSS

ENERGY& WATER

COST

SAVINGS

TOTAL DISSOLVED SOLIDSTSS - Scale

LAMINAR BOUNDARY LAYER REDUCED = SAVINGSLAMINAR BOUNDARY LAYER REDUCED = NO SCALE = SAVINGS

WITH

= 10-15%Energy andWater Savings

RECLEAN PRO™ 4

RECLEAN PRO™ System Installed February 2012TOTAL 24-MONTH WATER SAVINGS = 4,374,728 Gallons

Current Use Adjusted for Days and Temperature

RECLEAN PRO™ 5

4200-TON CHILLER SYSTEMS

CLOSED LOOP FILTER

BOILER SYSTEMS

1500-TON CHILLER SYSTEMS

RECLEAN PRO™ 6

New Jersey Pharmaceutical ApplicationNorth & South Chiller Plants

Total System: 15,000-tons plus

RECLEAN PRO™ 7

Electrohydrodynamic Heat Transfer

The air conditioning and refrigeration industry has been increasing the efficiency of its equipment dramatically. One of the biggest contributors to these efficiency gains in the past has been the modification of heat exchangers to use enhanced surfaces, such as attached/integral fins, porous coatings, reentrant cavities and internal grooving. Today, a radically new method of increasing heat transfer efficiency, called the electrohydrodynamic (EHD) technique, is being investigated. Some early results have shown more than a 1000 percent increase in heat transfer coefficients of R-134a.

What is EHD? How does it work?The EHD technique works by applying a high-voltage electrostatic potential field across a heat transfer fluid, such as a refrigerant or refrigerant mixture. The applied electric field serves to destabilize the thermal boundary layer, increasing boiling or condensation of the fluid near the heat transfer surface, and producing better mixing of the bulk fluid flow. The net effect is to increase the heat transfer coefficient, sometimes by several hundred percent. Although the EHD technique can be applied to both single phase and phase change heat transfer, it is more effective when applied to phase change processes (boiling and condensation).

How is the electric field applied?A common method for using the EHD effect is to suspend a charged electrode (for example, a straight wire running parallel to the tube) in the fluid medium and to electrically ground the heat transfer surface. The reverse case (charging the surface and grounding the wire) is also possible. The applied electric field can be either direct or alternating. The field polarity in most cases haslittle effect on the enhancement mechanism, particularly for the phase change processes. For shell-and-tube heat exchangers, the tube and shell sides can be simultaneously energized by placing electrodes in both the tube and shell sides. For plate heat exchangers there is no need for an external wire electrode, as the plates themselves can serve as the electrodes by charging one plate and grounding the other.

What are the benefits of EHD?lnitial studies have been done with several refrigerants, including R-123, R-134a, an R-11/ Ethanol mixture, and R-404A. The improvements in heat transfer are dramatic, especially at lower refrigerant qualities (more liquid and less vapor). This may allow manufacturers to produce highly compact heat exchangers with less complicated surfaces without sacrificing heat transfer efficiency.

Another potential application is to use continuously EHD enhancement with smaller, less costly heat exchangers. The EHD effect would offset the loss of heat transfer capacity experienced from the smaller heat exchanger. Similarly, EHD could be used in place of, or in conjunction with, enhanced surface heat exchangers

For more information, contact: Dr. Michael M. Ohadi, University of Maryland at College Park, Center for Environmental Energy Engineering, Department of Mechanical Engineering, College Park, MD 20742; (301 ) 405-5263; fax (301) 314-9477.

RECLEAN PRO™ 8

PARTICLE ANALYSIS REPORTPennsylvania Pharmaceutical Facility | Source: CT Basin Water

Test Method: Sample analyzed by electro-optical particle analyzer employing the light scattering principle of operation with filtered water and particle data corrected Stirring was continuous.

Baseline - Prior to RECLEAN PRO System After 3 months with RECLEAN PRO System

PARTICLE COUNTS PER 100mL TEST PORTION PARTICLE COUNTS PER 100mL TEST PORTION

1 - 3 micron: 8,352,320 1 - 3 micron: 835,5083 - 5 micron: 1,568,520 3 - 5 micron: 23,0905- 10 micron: 1,708,520 5 - 10 micron: 48,44010 - 15 micron: 572,480 10- 15 micron: 18,70615-25 micron: 776,640 15-25 micron: 6,570Over 25 micron: 431.680 Over 25 micron: 5,648TOTAL/100mL: 13,410,160 TOTAL/100mL: 937,962

SOLIDS PER 100 LITERS OF SYSTEM VOLUME ( mm3 ) SOLIDS PER 100 LITERS OF SYSTEM VOLUME ( mm3 )

1-5 micron: 167.20 1 -5 micron: 8.16

5- 10 micron: 721.00 5 - 10 micron: 20.44

Over 10 micron: 295.516.85 Over 10 micron: 3.839.93TOTAL/100 Liters: 296,405.05 2,964 ppm TOTAL/100 Liters: 3,868.53 39 ppm

PARTICLE ANALYSIS REPORTPennsylvania Pharmaceutical Facility | Test conducted in a pharmaceutical facility

800-ton process chiller/cooling tower system with a 3,000 gallon capacity

Test Method: Sample analyzed by electro-optical particle analyzer employing the light scattering principle of operation with filtered water and particle data corrected

Baseline - Prior to RECLEAN PRO System After 3 months with RECLEAN PRO System

PARTICLE COUNTS PER 100mL TEST PORTION PARTICLE COUNTS PER 100mL TEST PORTION

1 - 3 micron: 1,309,584 1 -3 micron: 159,7063 - 5 micron: 101,488 3 - 5 micron: 25,6265 - 10 micron: 63,808 5 - 10 micron: 13,42210-15micron: 11,952 10 - 15 micron: 1,99215 - 25 micron: 13,056 15-25 micron: 2,182Over 25 micron: 22.720 Over 25 micron: 1,306TOTAL/100mL: 1,522,608 TOTAL/100mL: 204,234

SOLIDS PER 100 LITERS OF SYSTEM VOLUME ( mm3 )

TOTAL/100 Liters: BEFORE: 15,371 (154 ppm) TOTAL/100 Liters: AFTER: 901 (9 ppm)

NOTE: Typical sand filter for this application would use 300 gallons per backwash. RECLEAN PRO filter backwash water used: 0

RECLEAN PRO™ 9

Fast, easy installation

Condenser Open Loop

Piping: Inlet: One –Sch-80 PVC Outlet: One –Sch-80 PVC Drain: One –Sch-80 PVC

Option: Mild steel or copper piping may be used

Electrical: One 3-Phase 20-Amp Circuit

Chilled Water Closed Loop

Piping: Inlet: One –Sch-80 PVC Outlet: One –Sch-80 PVC Drain: One –Sch-80 PVC

NOTE: Piping and skid must be insulated

Pipe sizes will vary with tonnage capacity.

RECLEAN PRO™ 10

Ec-3000 Particle Precipitator Water Filtration Skid

RECLEAN PRO’s™ Particle Precipitator is a side-stream technology applied to open/closed loops in chilled water systems.

Pipe sizes will vary with tonnage capacity.We typically suggest Sch-80 PVC for the inlet, outlet and drain.

RECLEAN PRO™ 11

PARTIAL REFERENCE LIST

JOHNSON & JOHNSON HEADQUARTERSNew Brunswick, NJ(Chillers, Cooling Towers, Boilers, DHW, Filter)

JOHNSON HALL New Brunswick, NJ(Chillers, Cooling Towers, Boilers, DHW, Filter)

MERCK Summit, NJ(Chillers, Cooling Towers, Indoor Fountains)

MERCK Rahway, NJ (Chillers, Filter)

BRISTOL-MYERS SQUIBB New Brunswick, NJ(Chillers, Cooling Towers, Vacuum Pumps)

ROBERT WOODS JOHNSON FOUNDATION Princeton, NJ(Chiller, Cooling Towers, Filter)

JANSSEN PHARMACEUTICAL Raritan, NJ(Cooling Tower, Atlas Copco Air Compressors)

PPL (Pennsylvania Power & Light) Allentown, PA(Chi llers, Cooling Towers, Lobby Water Falls/ Fountain)

CHRISTIAN HEALTH CARE CENTER Wyckoff, NJ(Chillers, Cooling Towers, Filter, Heat Pumps)

PALL LIFE SCIENCE Fajardo, Puerto Rico(Chillers, Cooling Towers, Filter)

JANSSEN PHARMACEUTICAL Gurabo, Puerto Rico(Chillers, Cooling Towers)

ANHEUSER BUSCHMerrimack, NH(6000-ton Ammonia System w/Cooling Tower)

AT&T CITY CENTER Birmingham, AL(Chillers, Cooling Towers, Filter)

AT&T MAIN New Orleans, LA(Chillers, Cooling Towers, Filter) AT&T Wayne, PA(Chillers, Cooling Towers, Filter) AT&T Norfolk, VA(Chillers, Cooling Towers, Filter) PECO (Philadelphia Electric Company) Headquarters Bldg., Philadelphia, PA (Chillers, Cooling Towers, Filter)

PECO (Philadelphia Electric Company) Market Street Bldg., Philadelphia, PA (Chillers, Cooli ng Towers, Filter) PECO (Philadelphia Electric Company) Service Center Bldg., Philadelphia, PA (Chillers, Cooling Towers, Filter)

PECO (Philadelphia Electric Company)Plymouth Meeting, PA(Chillers, Cooli ng Towers, Filter)

HYATT REGENCY New Brunswick, NJ (Chillers, Cooling Towers)

BAYSIDE CONSULTING GROUP Gwynedd,PAEngineering Group

RECLEAN PRO™ 12

Advantages of a RECLEAN PRO™ SystemOver 30 years of HVAC experience with patented technology

Advantages to consider:

• Enhances current chemical program

• Documented 20-25% reduction in condenser loop make up water

• Documented increased energy efficiency due to more efficient thermo transfer

• Increased life cycles on equipment and reduction in maintenance costs

• Fast ROI – 24-30 months with installation

• Startup and 1st year service included in cost

• Monthly water chemistry testing

• Monitoring of water/energy use and equipment efficiencies (chillers and ooling towers)

• DDC monitoring of system with alarms

• Two-year warranty on all RECLEAN PRO™ equipment provided

• Ongoing continuous new technology available

At customer’s request a RECLEAN PRO™ local licensed representative will conduct a no cost survey of your water treatment mechanical equipment. If our technology is a fit for your building’s water treatment needs we will prepare a proposal for your consideration that will include both cost and projected savings to be realized.

RECLEAN PRO’s™ proposal will be a turn-key submission that includes design, manufacturing, installation, start-up, training and one year service. Our system is a totally automated skid-mount side-stream high tech water treatment system that addresses total dissolved and suspended solids. Each system comes with a touch screen PLC that can be interfaced with your building automation system. The PLC provides you with all the necessary information pertaining to your water treatment system such as conductivity, flow totalizers on filter, bleed and make-up, evaporation rates and alarms - control of TDS and TSS. RECLEAN PRO™ works with your local existing chemical company to assure peak performance in your water treatment system.

Each system is custom designed and proudly built in the United States.

* with patented Electrocell Technology